SPIRIT AT THE RIVER (FORMERLY LINCOLN CORRIDOR HOTEL) - FDP - FDP180015 - SUBMITTAL DOCUMENTS - ROUND 1 - PHOTOMETRIC PLAN
108 SUITES - SERVICE LOAD LOAD TOTAL VA GENERAL LIGHTING & RECEPTACLES TOTAL UNITS ALL TOGETHER: 37508 SF @ 3 VA PER SF 112,524 SMALL APPLIANCE LOAD (13) 2)1500W 39000 SMALL APPLIANCE LOAD REFRIGERATOR @ 1000 108000 DISHWASHER @ 1200 129600 DISPOSER @ 850 91800 MICROWAVE @ 1200 129600 COOKTOP @ 2000 216000 675,000 UNITS TOTAL 826,524 HEATING FOR UNITS @ 100% 220.84C(5) 404,352 COMPUTED UNIT LOAD (VA) 1,230,876 ESTIMATED LOAD @ 208 1 PH = (A) 5917.7 TOTAL NET COMPUTED LOAD FOR UNITS (VA) 1230876 NEC DEMAND FACTOR-TABLE 220.84 UNITS @ 23% 23% TOTAL NET COMPUTED LOAD FOR ALL UNITS 283101 ESTIMATED LOAD @ 120/208, 1 PH = (AMPS) 1361 ESTIMATED DEMAND @ 120/208V, 1 PH 283101 TOTAL NET COMPUTED LOAD FOR MDP 283101 ESTIMATED LOAD @ 120/208, 3 PH = (AMPS) 786 ESTIMATED DEMAND @ 120/208V, 3 PH 283101 M 3000A3P 30A3P TVSS 100A3P 400A3P 400A3P 400A3P 400A3P 400A3P 400A3P 400A3P 400A3P 400A3P 400A3P 52000AIC UTILITY TRANSFORMER EXTERIOR DETAIL NOTES: 1. NO LONGER USED. GENERAL NOTES: 1. ALL PANELBOARDS AND ELECTRICAL DISTRIBUTION EQUIPMENT SHOWN IS NEW UNLESS OTHERWISE NOTED. 2. ALL GROUNDING SHALL BE INSTALLED PER NEC ARTICLE 250. 3. PROVIDE NAMEPLATES FOR ALL SERVICE EQUIPEMENT PER NEC 705.10. 1 7 # NEW CU GND TO COLD WATER BOND AND BLDG STEEL, NEW CU GND TO DRIVERN GND ROD NEW MAIN DISTRIBUTION CENTER 'MDC' NEMA 1 3000A 120/208V 3PH 4W 65K AIC PANEL PANEL PANEL PANEL PANEL PANEL TRANSITION CABINET PANEL 1C 1A P1 400A3P 400A3P 8 EXTERIOR NEMA 3R CT/MAIN DISCONNECT PANEL H1 PANEL 400A3P PANEL 1E 400A3P 400A3P 400A3P 400A3P 400A3P M FEEDER SCHEDULE ALUMINUM CONDUCTORS ACCEPTED. NOT ALL FEEDERS IN SCHEDULE USED. (4#10 CU, 1#10 CU GND, 1/2"C) - 30A (4#4 CU, 1#8 CU GND, 1 3/4"C) 70A (4#2 AL, 1#6 AL GND, 1 3/4" C) 75A (4#1 CU, 1#8 CU GND, 2"C) 110A (4#1/O AL, 1#6 AL GND, 2"C) 120A (4#3/O CU, 1#6 CU GND, 2"C) 200A (4#250 AL, 1#4 AL GND, 3"C) 205A 2 SETS(4#3/O CU, 1#3 CU GND, 2"C) 400A 2 SETS(4#250 AL, 1#1 AL GND, 3"C) 410A 2 SETS(4#350 CU, 1#1 CU GND, 3"C) 620A 2 SETS(4#500 AL, 1#2/O AL GND, 3 1/2" C) 620A 8 SETS(4#500 CU MCM, 3"C) 3040A 11 SETS(4#500 CU, 1#500 CU GND, 3 1/2"C) 4180A 1 2 3 4 5 6 7 8 H6 H5 H4 H3 H2 PANEL HLCP HOTEL LIGHTING CONTROL PANEL PANEL PANEL 1D 1B PANEL 1F PANEL PANEL 2C 2A PANEL 2E PANEL PANEL 2D 2B PANEL 2F PANEL PANEL 2J 2G PANEL 2L PANEL PANEL 2K 2H PANEL 2M PANEL 2N PANEL 2O 2ND FLOOR SUITES 1ST FLOOR SUITES 1ST FLOOR AMENITIES/FOH PANEL PANEL 3C 3A PANEL 3E PANEL PANEL 3D 3B PANEL 3F PANEL PANEL 3J 3G PANEL 3L PANEL PANEL 3K 3H PANEL 3M PANEL 3N PANEL 3O 3RD FLOOR SUITES 400A3P 400A3P 400A3P 400A3P 400A3P 400A3P 200A3P 400A3P 400A3P 200A3P 200A3P PANEL PANEL 4C 4A PANEL PANEL 4D 4B 4TH FLOOR SUITES ELV. ELV. B A ELV. C 1 1 200A 3P 200A 3P 200A 3P PANEL 400A PANEL PANEL PANEL 200A 3P JONNY'S RESTAURANT JDP J1 J2 J3 J4 PANEL JLCP JONNY'S RESTAURANT LIGHTING CONTROL PANEL 4000A * MAIN BONDING JUMPER SHALL BE SIZED AS FOLLOWS: SERVICE SIZE M.B.J. SIZE CU 0-1,000A #3/0 1,200A #4/0 1,600A #250MCM 2,000A #300MCM 2,500A #500MCM 3,000A #500MCM 4,000A #600MCM * GROUNDING ELECTRODE CONDUCTOR BE SIZED AS FOLLOWS: SERVICE SIZE G.E.C. SIZE CU 0-200A #4 201-400A #1/0 OVER 401A #3/0 1 #* CU GROUND TO GROUNDED CONDUCTOR PER ART.250-28 PROVIDE PERMANENT TAG TO IDENTIFY EACH GROUND. FULL WIDTH x 1/2" DEPTH x 2" HIGH BARE COPPER BUS PLATE ATTACHED TO WALL WITH 1/2" SPACERS. REMOVE PAINT AT POINT OF ATTACHMENT TO SWITCHBOARD. 1/2" PORCELAIN INSULATORS 6" O.C. BETWEEN WALL AND COPPER GROUND BAR. 1 #6 CU-3/4" C, TO MAIN TELEPHONE BOARD. FINISH FLOOR 1 # ** CU-3/4"C. TO METAL UNDERGROUND WATER PIPE PER ART. 250.52(a)(1). 1 # ** CU-3/4"C. TO EFFECTIVELY GROUNDED METAL FRAME OF THE BLDG. PER ART. 250.52(a)(2). ONE 20 FT. LENGTH OF #3/0 BARE COPPER ENCASED IN MIN. 2" OF CONCRETE ALL AROUND PER ART. 250.52(a)(3). 52000AIC UTILITY TRANSFORMER EXTERIOR 7 TRANSITION CABINET PANEL PL1 100A3P NEMA 3R DISCONNECT WITH FRN FUSES M 100A 208 3PH PANEL 3 ARCHITECT'S PROJECT NUMBER COPYRIGHT © 2013 PAUL T. BERGNER, AIA, ARCHITECT, PC/ALL RIGHTS RESERVED SHEET NUMBER SHEET TITLE CURRENT PHASE ISSUE DATE THESE DRAWINGS ARE INCOMPLETE AND ARE INTENDED FOR CONVEYING DESIGN SYSTEM CONCEPTS. ANY PRICING OR BUDGETING PERFORMED WITH THESE DRAWINGS MUST CARRY A CONTINGENCY TO COVER WHAT ITEMS MAY CHANGE OR BE ADDED AS THE DESIGN PROCESS IS COMPLETED. WILLCO XIV LLLP 4100 Wadsworth Blvd. Wheat Ridge, CO 80033 p. 303.985.3260 6/12/2018 5:17:56 PM E400 ONE LINE DIAGRAM STAYBRIDGE SUITES 301 EAST LINCOLN AVE. FORT COLLINS, CO N/A 06.01.2018 No. Description Date N.T.S. 1 PRELIMINARY ONE-LINE DIAGRAM N.T.S. 2 MAIN SYSTEM GROUND DETAIL N.T.S. 3 SECONDARY ONE DIAGRAM