Loading...
HomeMy WebLinkAboutTHE RETREAT AT FORT COLLINS (FORMERLY REDWOOD STREET MULTI-FAMILY) - PDP - PDP180002 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANSN. COLLEGE AVE. E VINE DR. CONIFER ST. REDWOOD TRAIL N. LEMAY AVE. PRIVATE STREET w/ PARKING INTERNAL STREETS PRIVATE STREET INTERNAL STREETS SUNIGA DRIVE FOUR-LANE ARTERIAL STREET (PROPOSED BY NORTHFIELD - FILING 1) SUNIGA DRIVE FOUR-LANE ARTERIAL INTERSECTION DETAIL (PROPOSED BY NORTHFIELD - FILING 1) Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C0.00 COVER SHEET CONTACT INFORMATION PROJECT TEAM: I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: PROJECT LOCATION VICINITY MAP Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C0.01 NOTES GENERAL & CONSTRUCTION 2 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner A. GENERAL NOTES 1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. S H Y D WV F E S S C S WV WV V.P. V.P. D H2O D V.P. F E S F E S F E S MH ELEC MH H Y D D MW MW H2O WV WV WV H2O W WV WV WV W H2O MW W h2o F E S D D VAULT CABLE D D IRR D D S H Y D WV S C S WV WV V.P. V.P. D H2O D V.P. F E S F E S F E S MH ELEC MH H Y D D MW MW H2O WV WV WV H2O W WV WV WV W H2O MW W h2o F E S D D VAULT CABLE D D IRR D D ELEC VAULT ELEC S H Y D WV S C S WV WV V.P. V.P. D H2O D V.P. F E S F E S F E S MH ELEC MH H Y D D MW MW H2O WV WV WV H2O W WV WV WV W H2O MW W h2o F E S D D VAULT CABLE D D IRR D D ELEC VAULT ELEC X X E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E S W F F F F F F F W W W W W W W S S S S S S S S F W F F W N YL OP L AS T D U C T LI E RI O N T E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E W W S S F F F F F F W W T T F F F F F F F F W W W W W W W W W W F S S S S S S S S S S S F E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E F F F F F W W W W W W S S S S S S S E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E F F F F F F F F W W W W W W W W D D F E S F E S F E S MH MH D F E S D D D D D D D D D D D D 12" W 12" W 12" W 60" W 60" W 60" W 60" W 42" W 42" W 42" W X X ST ST ST ST ST ST ST ST ST ST ST util D T ST ST ST D (13) SPACES (16) SPACES X X X X X X X X X X X X X X X X X X X X X X X D D F E S F E S MH MH D MW MW MW D VAULT CABLE D D IRR D D D D D C C C D 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X D MW MW MW 12" W 12" W 12" W 60" W 60" W D N YL OP L AS T D U C T LI E RI O N STREET E (13) SPACES (16) SPACES (13) SPACES (15) SPACES (12) SPACES (9) SPACES UP TYP. UP ELEVATOR TYP. H.C. SPACE TYP. UP 42" HIGH CHAIN LINK FENCE BARRIER (TYP.) 42" HIGH CHAIN LINK FENCE ENCLOSURE (TYP.) STORAGE AREA BELOW RAMP X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X UP NY LO PL AS T D U C T LI E I R O N AS T PL NY LO UD C T LI E I R O N PROPOSED INLET PROPOSED STORM DRAIN LAKE CANAL FUTURE NORTHFIELD SUBDIVISION 1ST FILING EVERGREEN PARK 3RD FILING PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PANS 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 5' SIDEWALK PROPOSED OUTLET STRUCTURE DETENTION POND 2 PROPOSED 10' TRAIL PROPOSED DRAIN BASIN PROPOSED 2' CONCRETE PAN PROPOSED STORMTECH MC3500 DETENTION CHAMBERS PROPOSED INLET PROPOSED STORMTECH MC3500 DETENTION CHAMBERS 5' SIDEWALK 6' SIDEWALK STREET A T S D U C T I L E I OR N STREET A (PRIVATE STREET) STREET B 57' ACC., E.A.E., U.E. 36' FL-FL & D.E. 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 6' CROSS-PAN STREET B SEE SHEET C5.02 R15' R15' R15' R15' STREET A ( PRIVATE STREET) REDWOOD STREET 57' ACC., E.A.E., U.E. & D.E. 36' FL-FL 36' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 6' SIDEWALK 6' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK STA. = 14+31.90 (STREET A) STA. = 12+65.20 (STREET E) ∆ ∆ 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 4957.88 4957.80 4957.78 4957.84 4957.95 4958.08 4958.20 4958.33 4958.45 4958.58 4958.72 4958.94 4959.17 4959.39 4959.62 4959.83 4959.88 4959.73 4959.37 4958.87 4959.04 4958.53 4958.68 4958.80 4958.75 4958.62 4958.56 4958.58 4958.68 4958.84 4958.99 4959.14 4959.30 4959.49 4959.70 4959.89 4960.03 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND -0.50% 0.61% 0.61% 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 4957.83 4958.78 4959.56 4960.34 4961.12 4961.90 4962.94 4963.55 4957.49 4957.99 4958.46 4958.98 4959.18 4959.37 4959.76 4959.95 4960.15 4960.54 4960.73 4960.93 4961.32 4961.51 4961.71 4962.15 4962.11 4962.59 4963.12 4963.26 4963.41 4963.70 4963.84 4963.98 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED SUBGRADE SUBGRADE MINUS 3' APPROXIMATE GROUNDWATER -2.25% VAULT ELEC ST ST ST ST ST ST ST ST ST TRACT A REPLAT OF EVERGREEN PARK 2ND FILING ∆ STA. = 10+00.00 ∆ 24' FL-FL PROJECT BOUNDARY (TYP.) CONIFER STREET 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT STREET B (PRIVATE STREET) 60.4' ACC., E.A.E. U.E. & D.E. EXISTING VERTICAL CURB & GUTTER PROPOSED EXTENDED 12" RCP CULVERT CITY OF FORT COLLINS EXISTING VERTICAL CURB & GUTTER EXISTING 12" RCP CULVERT HIGH VOLUME DRIVE R15' R15' 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 23+00 22+00 21+00 20+00 19+00 18+00 4964.59 4964.19 4963.54 4964.27 (16) SPACES UP STREET C (PRIVATE STREET) 57' ACC., E.A.E., U.E & D.E. 36' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK STA. = 12+34.56 (STREET C) STA. = 15+19.02 (STREET B) STA. = 17+39.10 (STREET C) STA. = 24+28.78 (STREET A) ∆ TRACT A R20' R20' PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER STREET B SEE SHEET C5.02 STREET B SEE SHEET C5.02 STREET A SEE SHEET C5.01 STREET A SEE SHEET C5.01 PROPOSED 6' CROSS-PAN PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT R20' & SIDEWALK CHASE R20' R20' R20' R20' 60' E.A.E, R20' U.E. & D.E. 4950 4955 4960 4965 4970 4975 4950 4955 4960 T Y LO PL AS N D U C T LI E I OR N (13) SPACES (16) SPACES (13) SPACES (15) SPACES (12) SPACES (9) SPACES UP TYP. UP ELEVATOR TYP. H.C. SPACE TYP. 42" HIGH CHAIN LINK FENCE BARRIER (TYP.) 42" HIGH CHAIN LINK FENCE ENCLOSURE (TYP.) STORAGE AREA BELOW RAMP STREET G (PRIVATE STREET) 81.4' ACC., E.A.E., U.E. & D.E 20' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK PROPOSED 30" VERTICAL CURB & GUTTER STREET B SEE SHEET C5.02 STREET B SEE SHEET C5.02 STREET A SEE SHEET C5.01 PROPOSED 30" VERTICAL CURB & GUTTER STA. = 17+58.00 (STREET G) STA. = 28+92.82 (STREET A) ∆ ∆ PROPOSED STORM DRAIN PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT D 12" W 12" W 12" W 12" W 60" W 60" W 60" W 42" W 42" W D STREET E (PRIVATE STREET) 36' ACC., E.A.E., U.E. & D.E. 20' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK ∆ STA. = 12+65.20 (STREET E) STA. = 14+31.90 (STREET A) R20' R20' PROPOSED STORM DRAIN PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER STREET A STREET A SEE SHEET C5.00 STREET A SEE SHEET C5.00 FUTURE SUNIGA DRIVE (BY OTHERS) PROPOSED 6' CROSS-PAN 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 9+50 10+00 11+00 12+00 13+00 -2.00% -2.00% -1.87% V.P. V.P. D D V.P. D D D D D ELEC VAULT ELEC VAULT ELEC D D D VAULT ELEC 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 42" W 42" W 42" W 42" W 42" W 42" W 42" W 42" W 42" W ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST D X X V.P. V.P. D D V.P. F E S F E S F E S MH ELEC MH D MW MW MW F E S D D VAULT CABLE D D IRR D D ELEC VAULT ELEC VAULT ELEC D D D VAULT ELEC D CC C C C D 12" W 12" W 12" W 60" W 60" W 60" W 60" W 42" W 42" W 42" W X X S V.P. V.P. D H2O D V.P. F E S F E S F E S MH ELEC MH D MW MW H2O WV WV WV H2O W WV WV WV W H2O MW W h2o F E S D D VAULT CABLE D D IRR D D ELEC VAULT ELEC H2O VAULT ELEC H2O D WV WV WV WV H Y D D D VAULT ELEC D C D H Y D WV S H Y D WV WV S S S S WV WV WV S C C W C WV WV D X X X G ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST u til D X X X X X X X X X X X X X X X X X X X X X AJ - 4960.6 NGVD 29 AJ - 4963.77 NAVD 88 AL - 4962.04 NGVD 29 AL - 4965.21 NAVD 88 AI - 4960.31 NGVD 29 AI - 4963.48 NAVD 88 AH - 4956.21 NGVD 29 AH - 4959.38 NAVD 88 AK - 4961.08 NGVD 29 AK - 4964.25 NAVD 88 FEMA REGULATED 100-YR FLOODPLAIN FEMA REGULATED 100-YR FLOODWAY FEMA REGULATED 100-YR FLOODWAY FEMA REGULATED 100-YR FLOODPLAIN OWNER ROCKY MOUNTAIN RAPTOR PROGRAM STREET A (PRIVATE STREET) REDWOOD STREET FUTURE SUNIGA DRIVE (BY OTHERS) BLDG V BLDG U BLDG T BLDG S BLDG W BLDG Y BLDG X Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R C6.01 FLOODPLAIN EXHIBIT FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 24 LEGEND: PROJECT BOUNDARY PROPOSED STORM SEWER EXISTING STORM INLET PROPOSED CURB & GUTTER BASE FLOOD ELEVATION (BFE) EXISTING STORM MANHOLE D PROPOSED MAJOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MINOR CONTOUR NOTES: CROSS SECTION (CSL) EXISTING STORM SEWER ST 1. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION 2. THIS PROJECT IS LOCATED WITHIN A FEMA 100-YEAR FLOODWAY AND FLOOD FRINGE AND MUST COMPLY WITH CHAPTER 10 OF THE CITY CODE. 3. ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE PER NAVD 88 DATUM. 4. ANY ITEMS LOCATED IN THE FLOODWAY THAT CAN FLOAT (E.G., PICNIC TABLES, BIKE RACKS, ETC.) MUST BE ANCHORED. 5. THE LOWEST FLOOR AND THE FINISHED FLOOR FOR ANY BUILDING IN THE FLOODPLAIN SHALL BE FLOODPROOFED UP TO THE REGULATORY FLOOD PROTECTION ELEVATION. 6. A FLOODPLAIN USE PERMIT SHALL BE REQUIRED FOR EACH STRUCTURE AND EACH SITE CONSTRUCTION ELEMENT IN THE FLOODPLAIN. 7. A FLOODPLAIN USE PERMIT AND NO RISE CERTIFICATION IS REQUIRED PRIOR TO PERFORMING ANY WORK WITHIN THE FLOODWAY (I.E., CURB CUT REMOVAL, LANDSCAPING). 8. THE FLOODPLAIN USE PERMIT FOR THE BUILDING WILL BE SUBMITTED AT THE TIME OF THE BUILDING PERMIT APPLICATION. 9. A FLOODPROOFING CERTIFICATE SHALL BE COMPLETED AND APPROVED BEFORE THE CERTIFICATE OF OCCUPANCY IS ISSUED FOR ANY STRUCTURE IN THE FLOODPLAIN. 10. THE FLOODPROOFING REQUIREMENTS OF CHAPTER 10 OF THE CITY CODE WILL BE SATISFIED PRIOR TO ISSUANCE OF A BUILDING PERMIT. 11. NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY. 12. REFER TO THE PRELIMINARY DRAINAGE REPORT FOR THE RETREAT AT FORT COLLINS DATED JUNE 6, 2018 FOR ADDITIONAL INFORMATION. 15869 - 4984.50 NAVD 88 FEMA FLOODWAY FEMA FLOODPLAIN PROJECT BENCHMARKS: City of Fort Collins Benchmark Z 401: Elevation: 4962.74 (NAVD 88 Datum) Elevation: 4959.57 (NVGD 29) City of Fort Collins Benchmark 43-97: Elevation: 4960.11 (NAVD 88 Datum) Elevation: 4956.94 (NVGD 29) ST ST ST ST ST ST ST ST ST u til VAULT ELEC ST ST D T AS L N YLOP CUD T ELI I R NO T O PLAS L Y N D CU IT L IE NOR ST NYL OPLA D CU T ELI I R O N S T N YLOPLA CUD T ELI I R O N (13) SPACES (16) SPACES (13) SPACES (15) SPACES (12) SPACES (9) SPACES UP TYP. UP ELEVATOR TYP. H.C. SPACE TYP. UP 42" HIGH CHAIN LINK FENCE BARRIER (TYP.) 42" HIGH CHAIN LINK FENCE ENCLOSURE (TYP.) STORAGE AREA BELOW RAMP POND 2 RW1 RW2 RW3 RW4 RW5 UD1 UD2 UD3 UD4 UD1 UD2 UD3 RW5 RW4 RW2 RW1 RW3 FUTURE NORTHFIELD SUBDIVISION 1ST FILING REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 TRACT A REPLAT OF EVERGREEN PARK 2ND FILING LAKE CANAL LAKE CANAL OWNER ROCKY MOUNTAIN RAPTOR PROGRAM EVERGREEN PARK 3RD FILING OWNER BOARD OF COUNTY COMMISSIONERS EXISTING REDWOOD DETENTION POND POND 3 POND 4 POND 1 E1 C1 B4 B3 B2 C2 C3 C4 D1 D2 B1 A1 A2 A3 A5 A4 A6 A7 A8 A9 FEMA HIGH-RISK FLOODWAY FEMA HIGH-RISK FLOODPLAIN PROPOSED OUTLET STRUCTURE PROPOSED OUTLET STRUCTURE NECCO STORMLINE PROPOSED INLETS PROPOSED INLETS PROPOSED CURB CUTS EXISTING INLET PROPOSED INLET WQ CHAMBER B3 WQ CHAMBER B2 WQ CHAMBER C3 POND 6 WQ CHAMBER C1 WQ CHAMBER E1 POND 5 WQ CHAMBER A2 WQ CHAMBER A1 A3 A2 A3 A4 A5 A6 A7 A8 A9 B1 B2 B3 B4 C1 C2 C3 C4 D1 D2 E1 UD4 PLANNED INLETS PROPOSED INLETS PROPOSED INLETS PROPOSED OUTLET STRUCTURE PROPOSED OUTLET STRUCTURE PROPOSED CURB CUTS PROPOSED INLET PROPOSED INLET WQ CHAMBER A1 ( IN FEET ) 0 1 INCH = 100 FEET 100 100 200 300 Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROPERTY BOUNDARY EXISTING STORM SEWER 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE"Preliminary Drainage Report for The Retreat at Fort Collins dated June 6, 2018" FOR ADDITIONAL INFORMATION. NOTES: FLOW PATH DRAINAGE BASIN BUBBLE A DESIGN POINT A BASIN BOUNDARY PROPOSED STORM SEWER FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION C6.00 DRAINAGE EXHIBIT 23 Detention Pond Summary | Proposed Condition Pond Pond Description 100-yr Volume (cf) 100-yr Volume (ac-ft) 100-yr WSEL WQCV (cf) WQCV WSEL Max Release (cfs) 1 Open Detention 101,099 2.32 4955.73 2,708 4948.94 3.00 2 Open Detention 129,941 2.98 4955.10 2,064 4951.31 2.00 3.1 Underground Detention 23,368 0.54 to be provided at final 2,757 to be provided at final 15.65 3.2 Underground Detention 376 to be provided at final 4.1 Underground Detention 18,855 0.43 to be provided at final 541 to be provided at final 0.40 4.2 Underground Detention 533 to be provided at final 5 Underground Detention 6,255 0.14 to be provided at final 412 to be provided at final 0.20 6 Underground Detention n/a n/a n/a 5,646 to be provided at final n/a 7 Underground Detention 19,411 0.45 to be provided at final 1,490 to be provided at final 3.40 NORTH DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) A1 A1 0.96 0.53 0.66 5.0 5.0 1.45 6.33 A2 A2 3.58 0.69 0.86 12.6 11.7 4.94 22.32 A3 A3 0.20 0.80 1.00 5.0 5.0 0.47 2.04 A4 A4 1.33 0.77 0.96 9.6 8.1 2.30 10.68 A5 A5 2.60 0.68 0.85 12.6 11.9 3.56 16.12 A6 A6 0.94 0.62 0.77 5.0 5.0 1.66 7.22 A7 A7 0.41 0.70 0.88 7.0 5.0 0.74 3.55 A8 A8 0.62 0.71 0.88 7.8 5.6 1.07 5.24 A9 A9 4.04 0.38 0.48 9.5 8.6 3.47 15.76 B1 B1 3.91 0.63 0.79 8.7 7.4 5.79 27.12 B2 B2 0.25 0.82 1.00 5.0 5.0 0.58 2.48 B3 B3 0.22 0.77 0.97 5.0 5.0 0.48 2.09 B4 B4 2.92 0.49 0.61 13.0 11.6 2.89 13.05 C1 C1 0.81 0.78 0.98 11.0 6.2 1.38 7.39 C2 C2 0.35 0.75 0.94 5.0 5.0 0.74 3.25 C3 C3 0.29 0.78 0.98 5.0 5.0 0.64 2.81 C4 C4 1.01 0.45 0.56 7.6 6.8 1.12 5.14 D1 D1 0.69 0.68 0.85 5.3 5.0 1.35 5.89 D2 D2 0.83 0.47 0.58 5.0 5.0 1.11 4.84 E1 E1 0.90 0.56 0.70 9.3 7.5 1.15 5.38 UD1 UD1 0.54 0.57 0.72 7.4 5.8 0.78 3.72 UD2 UD2 1.17 0.80 1.00 5.0 5.0 2.68 11.66 UD3 UD3 2.32 0.30 0.37 32.0 29.0 0.86 3.96 UD4 UD4 0.44 0.62 0.78 7.4 5.9 0.70 3.33 RW1 RW1 3.42 0.45 0.56 15.9 14.7 2.83 12.71 RW2 RW2 1.08 0.45 0.56 9.6 8.4 1.09 5.08 RW3 RW3 0.10 0.45 0.56 6.8 5.6 0.12 0.55 RW4 RW4 1.20 0.45 0.56 9.6 8.4 1.22 5.65 RW5 RW5 0.31 0.45 0.56 6.8 5.6 0.37 1.69 STREET E (PRIVATE STREET) REDWOOD STREET SIGHT DISTANCE EASEMENT 6' BIKE LANE 12' TRAVEL LANE 11' TRAVEL LANE 12' TURN LANE 6' BIKE LANE 11' TRAVEL LANE 12' TRAVEL LANE 7' MEDIAN EXISTING 54" NECCO STORM DRAIN FUTURE CULVERT CROSSING (BY OTHERS) FUTURE SUNIGA DRIVE (BY OTHERS) EXISTING STORM DRAIN FEMA HIGH RISK FLOODWAY FEMA HIGH RISK 100-YR FLOODPLAIN 6' SIDEWALK 15' UTILITY EASEMENT R25' R25' PROPOSED STORM DRAIN FUTURE NORTHFIELD SUBDIVISION 1ST FILING 57' ACC., E.A.E., U.E. & D.E. 20' FL-FL 114.98' ROW PROPOSED 18" VERTICAL OUTFALL CURB & GUTTER 10' SIDEWALK 15' UTILITY EASEMENT PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER PAVEMENT MARKING (TYP.) 5' TRAIL 10' TRAIL FUTURE NORTHFIELD SUBDIVISION 1ST FILING 9.5' PARKWAY 9.5' PARKWAY 3.5' BUFFER 3.5' BUFFER 19' MEDIAN FUTURE 30" STORM (BY OTHERS) R25' R25' 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 45+50 4960.62 4960.47 4960.37 4960.34 4960.37 4960.47 4960.64 4960.88 4961.16 4961.45 4961.70 4961.95 4962.18 4962.38 4962.54 4962.66 4962.74 4962.79 4962.79 4962.75 4962.68 4962.56 4962.41 4962.22 4961.99 4961.74 4961.49 4961.24 4960.99 4960.74 4960.49 4960.24 PROPOSED GRADE EXISTING GROUND FUTURE GRADE EXISTING GROUND TIE INTO NORTHFIELD FILING 1 DESIGN (BY OTHERS) PROPOSED SUBGRADE SUBGRADE MINUS 3' APPROXIMATE GROUNDWATER -0.59% -1.00% 1.14% 1.00% PVI STA = 37+62.37 PVI ELEV = 4960.70 PVI STA = 39+98.82 PVI ELEV = 4961.44 319.7' VC HP ELEV = 4962.79 HP STA = 42+14.41 PVI STA = 42+14.44 PVI ELEV = 4963.59 BVCS: 40+54.61 BVCE: 4961.99 EVCS: 43+74.27 EVCE: 4961.99 A.D. = 2.00 K = 160.00 160.0' VC LP ELEV = 4960.34 LP STA = 38+50.04 PVI STA = 38+75.52 PVI ELEV = 4960.03 BCVS: 37+95.52 BVCE: 4960.50 ECVS: 39+55.52 EVCE: 4960.94 A.D. = 1.74 K = 92.22 REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 NORTH C5.07 PLAN AND PROFILE SUNIGA DRIVE 22 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 6. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER CENTERLINE SUNIGA DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) SUNIGA 2.21% PVI STA = 10+00.00 PVI ELEV = 4962.79 PVI STA = 12+46.19 PVI ELEV = 4958.07 PVI STA = 10+30.51 PVI ELEV = 4962.18 PVI STA = 11+93.19 PVI ELEV = 4959.14 PVI STA = 12+65.20 PVI ELEV = 4958.49 4962.79 4962.29 4961.81 4961.35 4960.88 4960.41 4959.95 4959.48 4959.00 4958.50 4958.16 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED SUBGRADE SUBGRADE MINUS 3' APPROXIMATE GROUNDWATER REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C5.06 PLAN & PROFILE STREET E 21 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 6. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER NORTH CENTERLINE PRIVATE STREET E SCALE : 1" = 40' (H) 1" = 5' (V) STRT E & SIDEWALK CHASE PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT & SIDEWALK CHASE R20' R20' R15' R15' STA. = 10+00.00 (STREET G) STA. = 16+83.41 (STREET B) 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 4963.44 4962.87 4962.61 4962.49 4962.36 4962.24 4962.11 4961.99 4961.86 4961.74 4961.61 4961.49 4961.36 4961.24 4961.11 4960.99 4960.86 4960.74 4960.61 4960.49 4960.36 4960.24 4960.11 4959.99 4959.86 4959.73 4959.60 4959.48 4959.47 4959.59 4959.78 4959.89 4959.84 4959.66 4959.48 -2.27%-2.27% 0.78% -0.50% -0.50% -0.50% -0.53% -0.75% PVI STA = 10+00.00 PVI ELEV = 4963.44 PVI STA = 10+08.99 PVI ELEV = 4963.24 PVI STA = 10+32.75 PVI ELEV = 4962.70 PVI STA = 10+98.35 PVI ELEV = 4962.37 PVI STA = 12+31.47 PVI ELEV = 4961.70 PVI STA = 16+18.65 PVI ELEV = 4959.77 PVI STA = 18+66.99 PVI ELEV = 4959.35 60.0' VC HP ELEV = 4959.90 HP STA = 17+79.48 PVI STA = 17+78.91 PVI ELEV = 4960.01 BVCS: 17+48.91 BVCE: 4959.78 EVCS: 18+08.91 EVCE: 4959.78 A.D. = 1.53 K = 39.19 60.0' VC LP ELEV = 4959.46 LP STA = 16+89.93 PVI STA = 16+95.72 PVI ELEV = 4959.36 BCVS: 16+65.72 BVCE: 4959.52 ECVS: 17+25.72 EVCE: 4959.60 A.D. = 1.31 K = 45.90 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 12" RCP STORM STA.=14+67.00 INV.=4955.08 12" RCP STORM STA.=16+86.58 INV.=4953.12 REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 NORTH C5.05 PLAN & PROFILE STREET G 20 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 6. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER CENTERLINE PRIVATE STREET G SCALE : 1" = 40' (H) 1" = 5' (V) STRT G 4965 4970 4975 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 4961.08 4961.70 4962.12 4962.34 4962.33 4962.21 4962.08 4961.95 4961.82 4961.69 4961.56 4961.44 4961.31 4961.18 4961.05 4960.92 4960.75 4960.52 4960.29 4960.07 4959.84 4959.62 4959.39 4959.16 4959.01 4958.89 4958.76 -0.51% -0.90% -0.50% 2.57% PVI STA = 15+13.08 PVI ELEV = 4960.85 PVI STA = 17+06.29 PVI ELEV = 4959.11 90.0' VC HP ELEV = 4962.36 HP STA = 12+12.22 PVI STA = 11+82.22 PVI ELEV = 4962.55 BVCS: 11+37.22 BVCE: 4961.40 EVCS: 12+27.22 EVCE: 4962.32 A.D. = 3.08 K = 29.19 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED SUBGRADE SUBGRADE MINUS 3' APPROXIMATE GROUNDWATER STA.=17+39.10 INTERSECTION REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 NORTH C5.04 PLAN & PROFILE STREET C 19 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 6. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER CENTERLINE PRIVATE STREET C SCALE : 1" = 40' (H) 1" = 5' (V) STRT C 4964.42 4964.54 4964.56 4964.46 4964.33 4964.06 4963.92 4963.79 4963.11 4962.67 4963.16 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED SUBGRADE SUBGRADE MINUS 3' 2.31% -2.00% -0.54% PVI STA = 21+47.40 PVI ELEV = 4962.67 PVI STA = 21+53.40 PVI ELEV = 4962.67 PVI STA = 21+81.87 PVI ELEV = 4963.32 90.0' VC HP ELEV = 4964.59 HP STA = 19+03.90 PVI STA = 19+02.47 PVI ELEV = 4964.72 BVCS: 18+57.47 BVCE: 4964.46 EVCS: 19+47.47 EVCE: 4964.47 A.D. = 1.12 K = 80.68 50.0' VC PVI STA = 20+97.40 PVI ELEV = 4963.67 BVCS: 20+72.40 BVCE: 4963.80 EVCS: 21+22.40 EVCE: 4963.17 A.D. = 1.46 K = 34.25 12" RCP STORM STA.=20+72.82 INV.=4958.22 REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C5.03 PLAN & PROFILE STREET B 18 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 6. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER LINE MATCH STA 18+00 CENTERLINE PRIVATE STREET B SCALE : 1" = 40' (H) 1" = 5' (V) NORTH MATCH LINE SEE SHEET C5.02 STA 18+00 STRT B STRT B 2.00% 2.25% -2.25% 2.00% 0.78% PVI STA = 10+00.00 PVI ELEV = 4957.83 PVI STA = 10+16.00 PVI ELEV = 4957.47 PVI STA = 10+20.00 PVI ELEV = 4957.38 PVI STA = 10+24.00 PVI ELEV = 4957.47 PVI STA = 15+03.02 PVI ELEV = 4961.93 PVI STA = 15+19.02 PVI ELEV = 4962.29 PVI STA = 15+35.02 PVI ELEV = 4961.93 PVI STA = 15+38.02 PVI ELEV = 4961.85 PVI STA = 15+41.02 PVI ELEV = 4961.93 50.0' VC PVI STA = 10+83.30 PVI ELEV = 4958.66 BVCS: 10+58.30 BVCE: 4958.16 EVCS: 11+08.30 EVCE: 4958.85 A.D. = 1.22 K = 40.95 50.0' VC PVI STA = 15+91.02 PVI ELEV = 4962.93 BVCS: 15+66.02 BVCE: 4962.43 EVCS: 16+16.02 EVCE: 4963.07 A.D. = 1.42 K = 35.10 T S A L P O L Y N D U C T I L E RI O N STREET B (PRIVATE STREET) 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK STA. = 10+00.00 (STREET B) STA. = 19+35.39 (STREET A) ∆ ∆ STA. = 15+19.02 (STREET B) STA. = 12+34.56 (STREET C) 81.4' ACC., E.A.E., U.E. & D.E. PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER STREET A SEE SHEET C5.01 20' FL-FL 58' FL-FL STREET B (PRIVATE STREET) 9' UTILITY EASEMENT 4.5' SIDEWALK ∆ STA. = 16+83.41 (STREET B) STA. = 10+00.00 (STREET G) 4.5' SIDEWALK 9' UTILITY EASEMENT STREET C SEE SHEET C5.04 STREET C SEE SHEET C5.04 STREET G SEE SHEET C5.05 R20' R20' R20' R20' 60' E.A.E., U.E. & D.E. PROPOSED 2' CURB CUT & SIDEWALK CHASE REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C5.02 PLAN & PROFILE STREET B 17 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 LINE MATCH STA 18+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 6. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER NORTH STRT B STRT B CENTERLINE PRIVATE STREET B SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET C5.04 STA 18+00 0.85% 0.54% -2.00% 2.10% -3.21% -0.56% 0.50% 0.50% 0.90% PVI STA = 21+71.88 PVI ELEV = 4958.69 PVI STA = 24+05.69 PVI ELEV = 4958.76 PVI STA = 24+08.70 PVI ELEV = 4958.69 PVI STA = 24+11.71 PVI ELEV = 4958.76 PVI STA = 24+28.74 PVI ELEV = 4959.12 PVI STA = 24+45.78 PVI ELEV = 4958.57 PVI STA = 24+48.78 PVI ELEV = 4958.50 PVI STA = 24+51.78 PVI ELEV = 4958.57 PVI STA = 27+21.72 PVI ELEV = 4958.97 PVI STA = 27+83.83 PVI ELEV = 4959.35 PVI STA = 28+43.52 PVI ELEV = 4959.86 PVI STA = 28+76.11 PVI ELEV = 4960.03 90.0' VC HP ELEV = 4959.89 HP STA = 23+18.38 PVI STA = 23+35.35 PVI ELEV = 4960.17 BVCS: 22+90.35 BVCE: 4959.76 EVCS: 23+80.35 EVCE: 4959.27 A.D. = 2.90 K = 30.98 90.0' VC HP ELEV = 4958.86 HP STA = 25+31.53 PVI STA = 25+33.99 PVI ELEV = 4958.98 BVCS: 24+88.99 BVCE: 4958.75 EVCS: 25+78.99 EVCE: 4958.73 A.D. = 1.06 K = 85.08 90.0' VC LP ELEV = 4957.78 LP STA = 19+67.83 PVI STA = 19+67.83 PVI ELEV = 4957.67 BCVS: 19+22.83 BVCE: 4957.89 ECVS: 20+12.83 EVCE: 4957.89 A.D. = 1.00 K = 90.00 90.0' VC LP ELEV = 4958.56 LP STA = 26+31.10 PVI STA = 26+33.21 PVI ELEV = 4958.43 BCVS: 25+88.21 BVCE: 4958.68 ECVS: 26+78.21 EVCE: 4958.70 A.D. = 1.17 K = 76.89 APPROXIMATE GROUNDWATER PROPOSED SUBGRADE SUBGRADE MINUS 3' 15" RCP STORM STA.=19+67.83 INV.=4951.61 12" RCP STORM STA.=28+08.99 INV.=4952.32 12" RCP STORM STA.=26+31.10 INV.=4951.59 UP STREET A (PRIVATE STREET) 57' ACC., E.A.E, U.E. & D.E. 36' FL-FL 57' ACC., E.A.E., U.E. & D.E. 36' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK STA. = 19+35.39 (STREET A) STA. = 10+00.00 (STREET B) STA. = 24+28.78 (STREET A) STA. = 17+39.10 (STREET C) MODIFIED HANDICAP RAMP (TYP.) MODIFIED HANDICAP RAMP (TYP.) R20' R20' PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER STREET B SEE SHEET C5.02 STREET C SEE SHEET C5.04 PROPOSED STORM DRAIN STREET G SEE SHEET ---- PROPOSED 6' CROSS-PAN PROPOSED 6' CROSS-PAN PROPOSED 6' CROSS-PAN PROPOSED STORM DRAIN ∆ R15' R15' R15' R15' R15' R15' R20' R20' STA. = 28+92.82 (STREET A) STA. = 17+58.00 (STREET G) PROPOSED 2' CURB CUT & SIDEWALK CHASE REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C5.01 PLAN & PROFILE STREET A 16 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 LINE MATCH STA 19+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 6. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER NORTH MATCH LINE SEE SHEET C5.00 STA 19+00 CENTERLINE PRIVATE STREET A SCALE : 1" = 40' (H) 1" = 5' (V) STRT A STRT A ∆ PROPOSED 6' CROSS-PAN R20' R20' FEMA HIGH RISK FLOODWAY PROPOSED STORM DRAIN PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER STREET E SEE SHEET C5.06 HIGH VOLUME DRIVE PROPOSED 6' CROSS-PAN R20' R20' R15' R15' R15' R15' 56' E.A.E., U.E. & D.E. 57' ACC., E.A.E., U.E. & D.E. R15' R15' 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 4960.03 4959.60 4960.08 4960.64 4960.99 4961.14 4961.08 4960.90 4960.70 4960.51 4960.32 4960.13 4959.94 4959.75 4959.56 4959.37 4959.18 4958.99 4958.80 4958.61 4958.42 4958.23 4958.04 4957.86 4957.76 4957.75 4957.82 4957.95 4958.07 4958.20 4958.32 4958.41 4958.43 4958.37 4958.26 4958.13 -1.69% 2.50% -0.76% 0.50% -0.50% PVI STA = 10+00.00 PVI ELEV = 4960.03 PVI STA = 10+27.74 PVI ELEV = 4959.53 100.0' VC HP ELEV = 4961.14 HP STA = 11+30.73 PVI STA = 11+04.10 PVI ELEV = 4961.44 BVCS: 10+54.10 BVCE: 4960.19 EVCS: 11+54.10 EVCE: 4961.05 A.D. = 3.26 K = 30.65 90.0' VC HP ELEV = 4958.43 HP STA = 17+93.27 PVI STA = 17+93.27 PVI ELEV = 4958.54 BVCS: 17+48.27 BVCE: 4958.32 EVCS: 18+38.27 EVCE: 4958.32 A.D. = 1.00 K = 90.00 90.0' VC LP ELEV = 4957.74 LP STA = 16+15.77 PVI STA = 16+06.41 PVI ELEV = 4957.61 BCVS: 15+61.41 BVCE: 4957.95 ECVS: 16+51.41 EVCE: 4957.83 A.D. = 1.26 K = 71.29 PROPOSED GRADE EXISTING GROUND 48" RCP STORM STA.=14+74.64 INV.=4948.05 APPROXIMATE GROUNDWATER PROPOSED GRADE EXISTING GROUND SUBGRADE MINUS 3' PROPOSED SUBGRADE 12" RCP STORM STA.=14+13.81 INV.=4948.98 REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C5.00 PLAN & PROFILE STREET A 15 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 LINE MATCH STA 15+50 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 4. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 6. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER CENTERLINE PRIVATE STREET A SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 15+50 LINE MATCH STA 19+00 NORTH NORTH STRT A STRT A MATCH LINE SEE SHEET C5.01 STA 19+00 (PRIVATE STREET) BLDG L BLDG K BLDG J BLDG I BLDG H BLDG SS BLDG RR BLDG TT BLDG G BLDG F BLDG E 57' ACC. E.A.E., U.E. & D.E. 36' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 6' SIDEWALK 6' SIDEWALK 30' PEDESTRAIN ACCESS EASEMENT PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED INLET PROPOSED 10' TRAIL PROPOSED SIDEWALK CULVERT PROPOSED INLET CITY OF FORT COLLINS 2.3% 2.3% 2.3% 2.4% 2.3% 2.3% 4.0% 4.7% 2.8% 2.8% 3.0% 1.8% 1.8% 3.0% 4:1 10.2% 4.6% 16.0% 9.6% 4.4% 4.8% 13.2% 19.0% 4:1 24:1 4:1 4:1 4:1 4:1 6:1 7:1 4:1 4.2% 2.9% 2.9% 7.8% 1.8% 2.0% 2.0% 2.0% 2.3% 1.9% 13.0% REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C4.04 GRADING PLAN 14 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 MATCHLINE-SEE SHEET C4.03 MATCHLINE-SEE SHEET C4.02 C4.01 C4.02 C4.03 C4.04 LEGEND: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT NOTES: EXISTING DECID. TREE EXISTING CONIF. TREE EXISTING LIGHT POLE EXISTING STUMP EXISTING STORM SEWER LINE ST EXISTING CURB/GUTTER FLOWLINE 4:1 BANK SLOPE PROPOSED ASPHALT CROSS SLOPE CONCENTRATED FLOW DIRECTION PROPOSED SWALE FLOWLINE PROPOSED OUTFALL CURB/GUTTER FLOWLINE PROPOSED STORM DRAIN WITH INLET PROPOSED CONTOUR EXISTING CONTOUR PROPOSED FINISH GROUND ELEVATION 79.45 (79.45) EXISTING GROUND ELEVATION PROPOSED INFLOW CURB/GUTTER FLOWLINE 2.0% 4950 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ST T S OP LA N YL D CU T LI E I R O N NY LO PL AS T D U C T LI E I R O N STREET B (PRIVATE STREET) STREET G (PRIVATE STREET) LUPINE DRIVE STREET C (PRIVATE STREET) PROPOSED STORM DRAIN PROPOSED INLETS REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 TRACT A REPLAT OF EVERGREEN PARK 2ND FILING EVERGREEN PARK 3RD FILING PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PANS PROPOSED 2' CONCRETE PANS PROPOSED 2' CONCRETE PAN 6' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 6' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 8' SIDEWALK 8' SIDEWALK 5' SIDEWALK PROPOSED STORM DRAIN TRACT A PROPOSED STORM DRAIN PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED DRAIN BASIN PROPOSED 2' CONCRETE PAN PROPOSED INLET PROPOSED STORMTECH MC3500 DETENTION CHAMBERS 6' SIDEWALK STREET A (PRIVATE STREET) STREET B (PRIVATE STREET) CONIFER STREET PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CONCRETE PAN PROPOSED EXTENDED CULVERT PROPOSED RETAINING WALL PROPOSED POND OUTLET STRUCTURE 8' SIDEWALK BLDG N CLUBHOUSE BLDG M BLDG L BLDG RR BLDG QQ BLDG TT BLDG E BLDG D BLDG C BLDG B BLDG NN BLDG PP BLDG OO BLDG MM BLDG A BLDG LL BLDG KK BLDG II BLDG JJ BLDG GG BLDG HH BLDG FF BLDG EE BLDG DD POOL AREA 60' E.A.E., U.E. & D.E. 81' ACC., E.A.E., U.E. & D.E 20' FL-FL 57' ACC., E.A.E., U.E & D.E 36' FL-FL 57' ACC., E.A.E., U.E. & D.E. 36' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 6' SIDEWALK 6' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 81' ACC., E.A.E, U.E., & D.E. PROPOSED GATE & KNOX BOX PROPOSED RETAINING WALL 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 24' FL-FL 41' ACC., E.A.E., U.E. & D.E. PROPOSED GATE & KNOX BOX PROPOSED POND OUTLET STRUCTURE 58' FL-FL 58' FL-FL PROPOSED INLET PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED INLET 2.4% 2.4% 2.3% 2.3% 2.3% 2.3% 2.3% 2.2% 2.3% 2.3% 2.3% 2.3% 2.4% 2.4% 2.6% 2.3% 2.5% 3.4% 1.6% 2.5% 2.8% 4.0% 4.7% 2.8% 2.8% 5.2% 9.4% 6.4% 6.4% 4.5% 2.3% 9.0% 11.7% 11.1% 10.3% 4:1 4:1 4:1 4:1 5:1 5:1 6:1 4:1 4:1 8.4% 10.9% 10.2% 4.6% 16.0% 9.6% 4.4% 7.8% 7.7% 6.3% 5.8% 18.2% 5.3% 7.7% 6.8% 7.5% 7.3% 7.7% 7.2% 5.5% 5.9% 16.5% 10.1% 7.8% 3.1% 4.9% PROPOSED STORMTECH MC740 DETENTION CHAMBERS REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C4.03 GRADING PLAN 13 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 MATCHLINE-SEE SHEET C4.04 MATCHLINE-SEE SHEET C4.02 C4.01 C4.02 C4.03 C4.04 LEGEND: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT NOTES: EXISTING DECID. TREE EXISTING CONIF. TREE EXISTING LIGHT POLE EXISTING STUMP EXISTING STORM SEWER LINE ST EXISTING CURB/GUTTER FLOWLINE 4:1 BANK SLOPE PROPOSED ASPHALT CROSS SLOPE CONCENTRATED FLOW DIRECTION PROPOSED SWALE FLOWLINE PROPOSED OUTFALL CURB/GUTTER FLOWLINE PROPOSED STORM DRAIN WITH INLET PROPOSED CONTOUR EXISTING CONTOUR PROPOSED FINISH GROUND ELEVATION 79.45 (79.45) EXISTING GROUND ELEVATION PROPOSED INFLOW CURB/GUTTER FLOWLINE 2.0% 4950 (PRIVATE STREET) PROPOSED STORM DRAIN PROPOSED STORM DRAIN FUTURE NORTHFIELD SUBDIVISION 1ST FILING LAKE CANAL REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 PROPOSED INLET PROPOSED INLET PROPOSED DRAIN BASIN PROPOSED 2' CONCRETE PAN 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 8' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORMTECH MC3500 DETENTION CHAMBERS PROPOSED STORMTECH MC3500 DETENTION CHAMBERS PROPOSED POND OUTLET STRUCTURE DETENTION POND 1 6' SIDEWALK 6' SIDEWALK PROPOSED 10' TRAIL PROPOSED 10' TRAIL PROPOSED INLET PROPOSED INLET 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK STREET A (PRIVATE STREET) STREET B (PRIVATE STREET) PROPOSED POND OUTLET STRUCTURE PROPOSED POND OUTLET STRUCTURE 8' SIDEWALK BLDG S BLDG Z BLDG AA BLDG R BLDG Q BLDG BB BLDG CC BLDG P BLDG O BLDG N CLUBHOUSE BLDG DD 57' ACC., E.A.E., U.E. & D.E. 36' FL-FL 57' ACC. E.A.E., U.E. & D.E. 36' FL-FL FUTURE CULVERT CROSSING (BY OTHERS) 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 6' SIDEWALK 6' SIDEWALK 36' ACC., U.E., D.E. 20' FL-FL 4.5' SIDEWALK 9' UTILITY EASEMENT 36' FL-FL 6' SIDEWALK PROPOSED GATE & KNOX BOX PROPOSED RETAINING WALL EASEMENTS REC. NO. 20100053124 30' PEDESTRAIN ACCESS EASEMENT 30' PEDESTRAIN ACCESS EASEMENT 6' SIDEWALK 24' E.A.E. & D.E. PROPOSED INLET 24' E.A.E. & D.E. PROPOSED POND OUTLET STRUCTURE FUTURE SUNIGA DRIVE (BY OTHERS) 14.0% 2.3% 3.1% 2.1% 2.8% 1.5% 0.8% 1.2% 1.0% 1.9% 4:1 7:1 2.1% 3.9% 6.5% 4:1 5:1 6:1 5:1 3:1 4:1 9:1 4:1 9:1 6:1 4:1 4:1 5:1 3:1 4:1 4:1 4:1 4:1 2.5% 2.8% 2.4% 2.4% 2.1% 2.1% PROPOSED SIDEWALK CULVERT 2.3% 2.3% 2.3% 2.4% 3.4% 2.5% 2.8% 4:1 4:1 3:1 5:1 5:1 11.4% 13.7% 4:1 4:1 7.5% 5.2% 7.5% 4.4% 5.2% 1.2% 2.0% 2.5% 1.2% 3.1% 2.9% PROPOSED STORMTECH MC4500 DETENTION CHAMBERS PROPOSED STORMTECH MC740 DETENTION CHAMBERS REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C4.02 GRADING PLAN 12 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 MATCHLINE-SEE SHEET C4.03 MATCHLINE-SEE SHEET C4.04 C4.01 C4.02 C4.03 C4.04 LEGEND: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT NOTES: EXISTING DECID. TREE EXISTING CONIF. TREE EXISTING LIGHT POLE EXISTING STUMP EXISTING STORM SEWER LINE ST EXISTING CURB/GUTTER FLOWLINE 4:1 BANK SLOPE PROPOSED ASPHALT CROSS SLOPE CONCENTRATED FLOW DIRECTION PROPOSED SWALE FLOWLINE PROPOSED OUTFALL CURB/GUTTER FLOWLINE PROPOSED STORM DRAIN WITH INLET PROPOSED CONTOUR EXISTING CONTOUR PROPOSED FINISH GROUND ELEVATION 79.45 (79.45) EXISTING GROUND ELEVATION PROPOSED INFLOW CURB/GUTTER FLOWLINE 2.0% 4950 MATCHLINE-SEE SHEET C4.01 42" W 42" W 42" W 42" W 42" W 42" W 42" W 42" W 42" W X X X X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST u til D X X STREET A (PRIVATE STREET) STREET E (PRIVATE STREET) REDWOOD STREET PROPOSED STORM DRAIN OWNER ROCKY MOUNTAIN RAPTOR PROGRAM REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 PROPOSED INLET PROPOSED 2' CONCRETE PAN 6' SIDEWALK 6' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 8' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK PROPOSED STORM DRAIN EXISTING 54" NECCO STORM DRAIN EXISTING STORM DRAIN CONNECT TO EXISTING STORM DRAIN MANHOLE FEMA HIGH RISK FLOODWAY FEMA HIGH RISK 100-YR FLOODPLAIN EXISTING STORM DRAIN PROPOSED POND OUTLET STRUCTURE DETENTION POND 1 FUTURE NORTHFIELD SUBDIVISION 1ST FILING EXISTING INLETS PROPOSED STORMTECH MC4500 DETENTION CHAMBERS 6' SIDEWALK 6' SIDEWALK 5' SIDEWALK 8' SIDEWALK BLDG V BLDG U BLDG T BLDG S BLDG W BLDG Y BLDG X BLDG Z 56' E.A.E., U.E. & D.E. 57' ACC., E.A.E, U.E. & D.E. 36' FL-FL FUTURE CULVERT CROSSING (BY OTHERS) 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 36' ACC., U.E., D.E. 20' FL-FL 36' FL-FL 24' EOP-EOP (TEMPORARY ACCESS) PROPOSED GATE & KNOX BOX 115' ROW EASEMENT REC. NO. 20100082084 EASEMENTS REC. NO. 20100053124 SLOPE &UTILITY EASEMENT REC. NO. 20170061770 DRAINAGE & UTILITY EASEMENT, REC. NO. 20170061770 PROPOSED DRAINAGE & UTILITY EASEMENT REC. NO. 20100053124 TO BE VACATED 9' UTILITY EASEMENT TRACT B FUTURE SUNIGA DRIVE (BY OTHERS) 2.1% 2.4% 2.4% 3.6% 3.9% 8.0% 6.4% 15.8% 5.4% 3.1% 2.0% 6.9% 6.5% 2.1% 8.3% 14.0% 2.3% 9.5% 5.8% 3.1% 2.1% 2.8% 2.4% 1.5% 0.8% 4:1 6:1 5:1 3:1 4:1 9:1 4:1 4:1 9:1 4:1 4:1 2.4% 2.4% PROPOSED SIDEWALK CULVERT 5.2% 15.4% 6.4% 3.1% 2.9% PROPOSED STORMTECH MC4500 DETENTION CHAMBERS REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C4.01 GRADING PLAN 11 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 MATCHLINE-SEE SHEET C4.02 MATCHLINE-SEE SHEET C4.02 C4.01 C4.02 C4.03 C4.04 LEGEND: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT NOTES: EXISTING DECID. TREE EXISTING CONIF. TREE EXISTING LIGHT POLE EXISTING STUMP EXISTING STORM SEWER LINE ST EXISTING CURB/GUTTER FLOWLINE 4:1 BANK SLOPE PROPOSED ASPHALT CROSS SLOPE CONCENTRATED FLOW DIRECTION PROPOSED SWALE FLOWLINE PROPOSED OUTFALL CURB/GUTTER FLOWLINE PROPOSED STORM DRAIN WITH INLET PROPOSED CONTOUR EXISTING CONTOUR PROPOSED FINISH GROUND ELEVATION 79.45 (79.45) EXISTING GROUND ELEVATION PROPOSED INFLOW CURB/GUTTER FLOWLINE 2.0% 4950 (13) SPACES (15) SPACES (12) SPACES (9) SPACES UP TYP. UP ELEVATOR TYP. TYP. H.C. SPACE UP 42" HIGH CHAIN LINK FENCE BARRIER (TYP.) 42" HIGH CHAIN LINK FENCE ENCLOSURE (TYP.) STORAGE AREA BELOW RAMP STREET A STREET A STREET A STREET B STREET G STREET C MULLEIN DRIVE STREET E REDWOOD STREET 6 10 11 NY LOPLA ST TCUD ELI NORI T S L OPLA Y N D U C T I IEL R NO S T OPLA NYL D U TC IELI OR N NY LOPLA ST TCUD ELI NORI DETENTION POND 2 DETENTION POND 1 FUTURE NORTHFIELD SUBDIVISION 1ST FILING REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 TRACT A REPLAT OF EVERGREEN PARK 2ND FILING LAKE CANAL LAKE CANAL OWNER ROCKY MOUNTAIN RAPTOR PROGRAM EVERGREEN PARK 3RD FILING OWNER BOARD OF COUNTY COMMISSIONERS FUTURE NORTHFIELD SUBDIVISION 1ST FILING FUTURE BOX CULVERT CROSSING (BY OTHERS) PROPOSED STORM DRAIN FUTURE SUNIGA DRIVE (BY OTHERS) PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED DETENTION CHAMBERS PROPOSED DETENTION CHAMBERS PROPOSED DETENTION CHAMBERS EXISTING 54" NECCO STORM DRAIN EXISTING STORM DRAIN CONNECT TO EXISTING STORM DRAIN MANHOLE TRACT A FEMA HIGH RISK FLOODWAY FEMA HIGH RISK 100-YR FLOODPLAIN EXISTING STORM DRAIN EXISTING STORM DRAIN PROPOSED POND OUTLET PROPOSED DETENTION CHAMBERS BLDG V BLDG U BLDG T BLDG S BLDG W BLDG Y BLDG X BLDG Z BLDG AA BLDG R BLDG Q BLDG BB BLDG CC BLDG P BLDG O BLDG N CLUBHOUSE BLDG M BLDG L BLDG K BLDG J BLDG I BLDG H BLDG SS BLDG RR BLDG QQ BLDG TT BLDG G BLDG F BLDG E BLDG C BLDG D BLDG B BLDG NN BLDG PP BLDG OO BLDG MM BLDG A BLDG LL BLDG KK BLDG II BLDG JJ BLDG GG BLDG HH BLDG FF BLDG EE BLDG DD POOL AREA CONNECT TO EXISTING STORM DRAIN PROPOSED POND OUTLET PROPOSED POND OUTLET PROPOSED POND OUTLET PROPOSED POND OUTLET PROPOSED POND OUTLET PROPOSED STORM DRAIN PROPOSED STORM DRAIN LUPINE DRIVE TEMPORARY ACCESS PROPOSED DETENTION CHAMBERS PROPOSED DETENTION CHAMBERS REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 NORTH CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 100 0 100 Feet 100 200 300 C3.01 C3.02 C3.03 C3.04 C4.00 OVERALL GRADING PLAN 10 LEGEND: 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E.= UTILITY EASEMENT D.E.= DRAINAGE EASEMENT NOTES: EXISTING DECID. TREE EXISTING CONIF. TREE EXISTING LIGHT POLE EXISTING STUMP EXISTING STORM SEWER LINE ST EXISTING CURB/GUTTER FLOWLINE 4:1 BANK SLOPE PROPOSED ASPHALT CROSS SLOPE CONCENTRATED FLOW DIRECTION PROPOSED SWALE FLOWLINE PROPOSED OUTFALL CURB/GUTTER FLOWLINE PROPOSED STORM DRAIN WITH INLET PROPOSED CONTOUR EXISTING CONTOUR PROPOSED FINISH GROUND ELEVATION 79.45 (79.45) EXISTING GROUND ELEVATION PROPOSED INFLOW CURB/GUTTER FLOWLINE 2.0% 4950 S S S S S S S S T N YL OP LA S D U C IT EL RI O N A ST P L N YL O UD C T I EL I R NO IR (12) SPACES UP FIRE HYDRANT 57' ACC. E.A.E., U.E. & D.E. 36' FL-FL SSMH A11 INV. IN=4950.74 (W) INV. OUT=4950.54 (E) FG=4959.60 SSMH A10 INV. IN=4950.36 (W) INV. OUT=4950.16 (SE) FG=4959.42 SSMH A9 INV. IN=4949.87 (NW) INV. OUT=4949.67 (SE) FG=4959.69 SSMH A8 INV. IN=4949.30 (NW) INV. OUT=4949.10 (SW) FG=4959.36 388.43 LF 8" PVC @ 0.40% 92.04 LF 8" PVC @ 0.40% 72.15 LF 8" PVC @ 0.40% 45.63 LF 8" PVC @ 0.40% LAKE CANAL FUTURE NORTHFIELD SUBDIVISION 1ST FILING EVERGREEN PARK 3RD FILING STMH 1-1.5 INV. IN=4949.39 (NE) INV. IN=4949.58 (NW) INV. OUT=4949.39 (SW) FG=4959.09 169.47 LF 24" RCP @ 0.20% STMH 1-1.6 INV. IN=4949.73 (NE) INV. IN=4949.89 (NW) INV. OUT=4949.73 (SW) FG=4959.08 36.87 LF 12" HDPE @ 3.17% STMH 1-1.6A-1 INV. IN=4951.06 (NE) INV. OUT=4951.06 (SE) FG=4957.79 324.28 LF 24" RCP @ 1.44% STMH 1-1.7 INV. IN=4954.40 (N) INV. OUT=4954.40 (SW) FG=4958.51 19.33 LF 24" RCP @ 1.45% OUTLET 1-1.8 INV. OUT=4954.69 (S) FG=4954.69 37.69 LF 12" HDPE @ 6.41% 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK DETENTION POND 2 PROPOSED STORMTECH MC3500 DETENTION CHAMBERS BLDG L BLDG K BLDG J BLDG I BLDG H BLDG SS BLDG RR BLDG TT BLDG G BLDG F BLDG E STREET A (PRIVATE STREET) OUTLET 1-1.4A INV. OUT=4952.77 (SE) PROPOSED GARBAGE ENCLOSURE 6' SIDEWALK 30' PEDESTRAIN ACCESS EASEMENT 50'' DITCH & DRAINAGE EASEMENT BOOK 2285 PAGE 1285 TO BE RE-PLATTED PROPOSED 10' TRAIL PROPOSED 10' TRAIL PROPOSED STORMTECH MC3500 DETENTION CHAMBERS INV. OUT=4955.66 (N) BASIN 1-1.6A-14 INV. IN=4953.80 (W) INV. IN=4953.80 (N) INV. OUT=4953.80 (E) FG=4959.76 58.26 LF 12" RCP @ 2.00% 123.83 LF 12" RCP @ 0.50% INLINE DRAIN 1-1.6A-14A INV. OUT=4954.97 (S) FG=4958.43 92.63 LF 12" RCP @ 2.00% INLET 1-1.6A-7B INV. OUT=4953.53 (SE) FG=4958.13 158.16 LF 24" RCP @ 0.20% CHBR 1-1.5A-1 INV. IN=4952.02 (SE) INV. IN=4952.02 (NW) INV. OUT=4952.02 (NE) FG=4958.03 9.18 LF 12" HDPE @ 0.50% INLET 1-1.5A-2 INV. OUT=4952.06 (NW) FG=4957.91 STMH 1-1.5A INV. IN=4952.00 (NW) INV. IN=4952.00 (SW) INV. IN=4952.00 (NE) INV. OUT=4952.00 (SE) FG=4958.34 CHBR 1-1.5C INV. OUT=4952.09 (SE) FG=4958.57 36.41 LF 12" RCP @ 0.50% BASIN 1-1.6A-13 INV. IN=4953.62 (W) INV. IN=4953.62 (N) INV. OUT=4953.62 (E) FG=4959.59 INLINE DRAIN 1-1.6A.13A INV. OUT=4953.88 (S) FG=4959.02 71.89 LF 12" RCP @ 0.50% INLET 1-1.6A-12 INV. IN=4953.26 (W) INV. OUT=4953.26 (SW) FG=4959.29 44.94 LF 12" RCP @ 0.50% STMH 1-1.6A-11 INV. IN=4953.04 (NE) INV. IN=4953.04 (SW) INV. OUT=4953.04 (SE) FG=4959.14 13.06 LF 12" RCP @ 2.00% INLET 1-1.6A-11A INV. OUT=4953.30 (NE) FG=4959.29 62.03 LF 12" RCP @ 0.50% STMH 1-1.6A-10 INV. IN=4952.73 (NW) INV. OUT=4952.73 (SE) FG=4959.49 99.99 LF 12" RCP @ 0.50% STMH 1-1.6A-9 INV. IN=4952.23 (NW) INV. OUT=4952.23 (SW) FG=4959.22 176.13 LF 12" RCP @ 0.50% STMH 1-1.6A-8 INV. IN=4951.35 (NE) INV. IN=4951.54 (NW) INV. OUT=4951.35 (SE) FG=4958.33 8.00 LF 12" RCP @ 0.50% INLET 1-1.6A-7 INV. IN=4951.31 (NW) INV. OUT=4951.31 (S) FG=4958.03 28.00 LF 12" RCP @ 0.50% INLET 1-1.6A-7A INV. IN=4951.68 (NW) INV. OUT=4951.68 (SE) FG=4958.03 67.94 LF 12" RCP @ 0.23% 12.85 LF 12" RCP @ 2.00% PROPOSED SIDEWALK CULVERT 5' SIDEWALK CITY OF FORT COLLINS IRRIGATION SERVICE (TYP.) INLET 1-1.5A-2 INV. OUT=4952.06 (NW) FG=4957.91 CHBR 1-1.6A-5 INV. IN=4951.15 (N) INV. OUT=4951.15 (SE) FG=4958.17 Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C3.04 UTILITY PLANS 9 REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE MATCHLINE-SEE SHEET C3.03 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE CONTROL IRR PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN SD 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E. = UTILITY EASEMENT D.E. = DRAINAGE EASEMENT NOTES: PROPOSED FIRE SERVICE F PROPOSED ELECTRIC E T PROPOSED TRANSFORMER MATCHLINE-SEE SHEET C3.02 C3.01 C3.02 C3.03 C3.04 NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E F F F F W W W W S S S S F F F F F W W W W S S S S S S S F F F W W W W W W S S S F F F F F W W S T S OP LA N YL D CU T LI E I R O N NY LO PL AS T D U C T LI E I R O N H Y D WV S C S WV WV E W VAULT ELEC ST (13) SPACES (16) SPACES (13) SPACES (15) SPACES (12) SPACES (9) SPACES UP TYP. UP ELEVATOR TYP. H.C. SPACE TYP. UP 42" HIGH CHAIN LINK FENCE BARRIER (TYP.) 42" HIGH CHAIN LINK FENCE ENCLOSURE (TYP.) STORAGE AREA BELOW RAMP FIRE HYDRANT FIRE HYDRANT 60' E.A.E., U.E. & D.E. 81.4' ACC., E.A.E., U.E. & D.E 20' FL-FL 57' ACC., E.A.E., U.E & D.E 36' FL-FL 57' ACC., E.A.E., U.E. & D.E. 36' FL-FL STMH 1-11 INV. IN=4952.59 (NW) INV. OUT=4952.59 (S) FG=4961.51 OUTLET 2-9.2 INV. OUT=4953.20 (SE) FG=4960.68 STMH 1-10 INV. IN=4952.17 (N) INV. OUT=4952.17 (S) FG=4960.32 STMH 1-8 INV. IN=4951.63 (N) INV. OUT=4951.63 (S) FG=4960.11 65.90 LF 48" RCP @ 0.49% 102.65 LF 48" RCP @ 0.41% 52.65 LF 48" RCP @ 1.16% SSMH A6-6 INV. OUT=4952.88 (S) FG=4963.31 SSMH A6-3 INV. IN=4950.55 (N) INV. OUT=4950.35 (S) FG=4961.14 SSMH A6-5 INV. IN=4952.59 (N) INV. OUT=4952.39 (S) FG=4962.90 SSMH A6-4 INV. IN=4951.60 (N) INV. IN=4951.60 (W) INV. IN=4951.60 (E) INV. OUT=4951.40 (S) FG=4962.04 SSMH A6-4EA INV. IN=4952.15 (E) INV. OUT=4951.95 (W) FG=4961.79 A6-4WA INV. IN=4952.20 (W) INV. OUT=4952.00 (E) FG=4961.84 SSMH A6-4WB INV. OUT=4952.50 (E) FG=4960.40 SSMH A6-2 INV. IN=4948.55 (N) INV. OUT=4948.35 (S) FG=4959.32 SSMH A6-4EB INV. OUT=4952.77 (W) FG=4961.14 488.39 LF 8" PVC @ 0.40% 119.53 LF 8" PVC @ 1.00% 200.16 LF 8" PVC @ 0.90% 106.24 LF 8" PVC @ 0.80% 99.17 LF 8" PVC @ 0.80% 71.41 LF 8" PVC @ 0.40% 80.16 LF 8" PVC @ 0.50% 69.56 LF 8" PVC @ 0.50% 60.62 LF 8" PVC @ 0.50% 123.67 LF 8" PVC @ 0.50% REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 TRACT A REPLAT OF EVERGREEN PARK 2ND FILING EVERGREEN PARK 3RD FILING STMH 1-9 INV. IN=4951.95 (N) INV. IN=4951.95 (W) INV. OUT=4951.95 (S) FG=4960.38 23.13 LF 15" RCP @ 0.64% STMH 1-9.1 INV. IN=4952.10 (N) INV. IN=4952.10 (S) INV. OUT=4952.10 (E) FG=4960.19 INLET 1-9.1a INV. OUT=4952.29 (N) FG=4959.61 10.46 LF 15" RCP @ 1.85% 25.79 LF 15" RCP @ 1.89% INLET 1-9.2 INV. OUT=4952.59 (S) FG=??? 43.94 LF 48" RCP @ 0.50% FIRE HYDRANT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK TRACT A 4.5' SIDEWALK 4.5' SIDEWALK SSMH A12 INV. IN=4952.54 (W) INV. OUT=4952.34 (E) FG=4961.59 399.60 LF 8" PVC @ 0.40% 81.4' ACC., E.A.E, U.E., & D.E. REMOVE PLUG AND CONNECT TO EXISTING STUB PROPOSED STORMTECH MC3500 DETENTION CHAMBERS STREET G (PRIVATE STREET) STREET C (PRIVATE STREET) BLDG N CLUBHOUSE BLDG M BLDG L BLDG RR BLDG QQ BLDG TT BLDG F BLDG E BLDG D BLDG C BLDG B BLDG NN BLDG PP BLDG OO BLDG MM BLDG A BLDG LL BLDG KK BLDG II BLDG JJ BLDG GG BLDG HH BLDG FF BLDG EE BLDG DD POOL AREA SSMH A13 INV. OUT=4953.15 (E) FG=4962.37 151.47 LF 8" PVC @ 0.40% STREET A (PRIVATE STREET) STREET B (PRIVATE STREET) 8" PVC WATER 8" PVC WATER 25.39 LF 12" HDPE @ 0.20% HEADWALL 1-1.4B INV. IN=4952.87 (SW) FG=4952.87 OUTLET 1-1.4A INV. OUT=4952.77 (SE) FG=4952.77 30.31 LF 12" HDPE @ 11.53% PROPOSED GATE & KNOX BOX PROPOSED RETAINING WALL LUPINE DRIVE EXISTING FIRE HYDRANT 8 " P V C W A T E R 8 " P V C W A T E R 8" PVC WATER 8 " P V C W A T E R 8" PVC WATER 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 24' FL-FL 40.7' ACC., E.A.E., U.E. & D.E. STREET B (PRIVATE STREET) CONIFER STREET PROPOSED OIL/SAND INTERCEPTOR FIRE HYDRANT PROPOSED GATE & KNOX BOX FIRE HYDRANT STMH 1-1.4C INV. IN=4952.93 (SW) INV. OUT=4952.93 (NE) FG=4958.48 CHBR 1-1.4D-1 INV. OUT=4953.10 (SE) FG=4957.98 HEADWALL 4-1 INV. IN=4957.95 (W) FG=4957.95 51.27 LF 12" RCP @ 0.62% TIE TO EXISTING 12" STORM INV. OUT=4958.27 (E) FG=4963.61 EXISTING 12" RCP CULVERT CITY OF FORT COLLINS ST 90° BEND 1-1.6A-16 INV. IN=4955.71 (N) INV. OUT=4955.71 (E) FG=4961.68 INLINE DRAIN 1-1.6A-17 INV. OUT=4956.08 (S) FG=4960.33 258.04 LF 12" RCP @ 0.50% 72.82 LF 12" RCP @ 0.50% INLET 1-1.6A-15A INV. OUT=4955.66 (N) FG=4960.40 61.85 LF 12" RCP @ 2.00% ST TEE 1-1.6A-15 INV. IN=4954.42 (W) INV. IN=4954.42 (S) INV. OUT=4954.42 (E) FG=4960.38 BASIN 1-1.6A-14 INV. IN=4953.80 (W) INV. IN=4953.80 (N) INV. OUT=4953.80 (E) FG=4959.76 58.26 LF 12" RCP @ 2.00% 123.83 LF 12" RCP @ 0.50% INLINE DRAIN 1-1.6A-14A INV. OUT=4954.97 (S) FG=4958.43 92.63 LF 12" RCP @ 2.00% INLET 1-1.6A-7B INV. OUT=4953.53 (SE) FG=4958.13 158.16 LF 24" RCP @ 0.20% 36.41 LF 12" RCP @ 0.50% PROPOSED OUTLET STRUCTURE TO REDWOOD POND REDWOOD POND OUTLET PIPE Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C3.03 UTILITY PLANS 8 REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE MATCHLINE-SEE SHEET C3.04 MATCHLINE-SEE SHEET C3.02 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE CONTROL IRR PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN SD 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E. = UTILITY EASEMENT D.E. = DRAINAGE EASEMENT NOTES: PROPOSED FIRE SERVICE F PROPOSED ELECTRIC E T PROPOSED TRANSFORMER C3.01 C3.02 C3.03 C3.04 NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 W W S S S S S S S S S W W W W W W F F F F F F F W S IR D H2O MW MW H2O WV WV WV H2O W WV WV WV W H2O MW W h2o 12" W 12" W 12" W 60" W 60" W D 57' ACC., E.A.E., U.E. & D.E. 36' FL-FL 57' ACC. E.A.E., U.E. & D.E. 36' FL-FL STMH 1-4 INV. IN=4948.80 (NE) INV. OUT=4948.80 (S) FG=4958.68 STMH 1-3 INV. IN=4948.24 (N) INV. OUT=4948.24 (S) FG=4958.28 STMH 1-5 INV. IN=4949.59 (N) INV. IN=4949.59 (SE) INV. OUT=4949.59 (SW) FG=4958.04 STMH 1-2 INV. IN=4947.59 (N) INV. OUT=4947.59 (S) FG=4956.19 132.44 LF 48" RCP @ 0.49% 114.14 LF 48" RCP @ 0.49% 163.32 LF 48" RCP @ 0.49% 48.56 LF 48" RCP @ 0.50% 49.51 LF 48" RCP @ 0.97% SSMH A6-1 INV. IN=4947.15 (N) INV. OUT=4946.95 (SE) FG=4958.39 SSMH A6 INV. IN=4945.40 (NE) INV. IN=4945.40 (NW) INV. OUT=4945.20 (SW) FG=4957.80 SSMH A5 INV. IN=4943.45 (NE) INV. OUT=4943.25 (SW) FG=4958.28 SSMH A3 INV. IN=4941.85 (N) INV. OUT=4941.65 (SW) FG=4961.28 SSMH A6-2 INV. IN=4948.55 (N) INV. OUT=4948.35 (S) FG=4959.32 73.31 LF 8" PVC @ 0.40% 488.39 LF 8" PVC @ 0.40% 77.27 LF 8" PVC @ 2.00% 119.53 LF 8" PVC @ 1.00% 177.42 LF 8" PVC @ 0.51% FUTURE NORTHFIELD SUBDIVISION 1ST FILING LAKE CANAL REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 34.31 LF 12" HDPE @ 3.23% 64.84 LF 24" RCP @ 0.22% 330.04 LF 24" RCP @ 0.20% STMH 1-1.2 INV. IN=4948.05 (NE) INV. IN=4948.05 (NW) INV. OUT=4948.05 (SW) FG=4957.86 171.17 LF 24" RCP @ 0.20% STMH 1-1.3 INV. IN=4948.39 (NE) INV. IN=4948.79 (NW) INV. OUT=4948.39 (SW) FG=4958.70 338.16 LF 24" RCP @ 0.20% STMH 1-6 INV. IN=4949.83 (N) INV. IN=4949.83 (W) INV. IN=4949.83 (E) INV. OUT=4949.83 (S) FG=4959.59 INLET 1-6.1A INV. OUT=4950.12 (E) FG=4960.37 14.37 LF 12" HDPE @ 2.00% 369.00 LF 48" RCP @ 0.49% 69.90 LF 48" RCP @ 0.49% FUTURE CULVERT CROSSING (BY OTHERS) DRAIN BASIN 1-5A-2.3 INV. OUT=4953.62 (SW) FG=4958.62 21.62 LF 6" HDPE @ 4.07% STRM BEND 1-5A-2.2 INV. IN=4952.74 (NE) INV. OUT=4952.74 (SW) FG=4959.14 48.13 LF 6" HDPE @ 4.00% CHBR 1-5A-2.1 INV. IN=4950.81 (NE) FG=4957.98 STMH 1 INV. IN=4946.77 (N) INV. OUT=4946.77 (SE) FG=4961.19 CONNECT TO BOX CULVERT INV. IN=4946.54 (NW) FG=??? 23.28 LF 48" RCP @ 0.97% FIRE HYDRANT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 36' ACC., U.E., D.E. 20' FL-FL EXISTING 42" WATER LINE (ELCO/NWCWD) EXISTING 60" WATER LINE (CITY OF GREELEY) 4.5' SIDEWALK 4.5' SIDEWALK PROPOSED STORMTECH MC3500 DETENTION CHAMBERS PROPOSED STORMTECH MC3500 DETENTION CHAMBERS DETENTION POND 1 PROPOSED STORMTECH MC3500 DETENTION CHAMBERS 9' UTILITY EASEMENT STREET E (PRIVATE STREET) STREET B (PRIVATE STREET) 90.10 LF 8" PVC @ 2.00% OUTLET 1-1.1a INV. OUT=4953.96 (S) FG=4953.99 437.77 LF 8" PVC @ 0.40% 36' FL-FL BLDG Z BLDG AA BLDG R BLDG Q BLDG BB BLDG CC BLDG P BLDG O BLDG N CLUBHOUSE BLDG M BLDG DD STREET A (PRIVATE STREET) 36.59 LF 12" HDPE @ 6.03% STMH 1-1.3A INV. IN=4950.99 (NW) INV. OUT=4950.99 (SE) FG=4957.70 STMH 1-1.2A INV. IN=4949.03 (NW) INV. OUT=4949.03 (SE) FG=4957.09 CHBR 1-1.2C INV. OUT=4950.50 (NW) INV. OUT=4950.50 (SE) FG=4957.02 INLET 1-1.2B INV. IN=4950.48 (NW) INV. OUT=4949.48 (SE) FG=4956.96 8" PVC WATER OUTLET 1-5.2 INV. OUT=4953.19 (NE) FG=4953.19 31.37 LF 12" RCP @ 8.30% STMH 1-5.1 INV. IN=4950.59 (SW) INV. IN=4950.59 (NE) INV. OUT=4950.59 (NW) FG=4957.37 12.04 LF 12" RCP @ 8.30% 30' PEDESTRAIN ACCESS EASEMENT 30' PEDESTRAIN ACCESS EASEMENT FUTURE NORTHFIELD SUBDIVISION 1ST FILING 8" PVC WATER 8" PVC WATER 6' SIDEWALK 6' SIDEWALK INLET 1-1.3C INV. IN=4951.52 (NW) INV. OUT=4951.52 (SE) FG=4957.21 36.67 LF 15" RCP @ 0.50% INLET 1-1.3D INV. OUT=4951.70 (SE) FG=4957.71 INLET 1-1.4F INV. OUT=4953.41 (NE) FG=4955.95 40.15 LF 12" HDPE @ 1.00% INLET 1-1.4E INV. IN=4953.01 (SW) INV. OUT=4953.01 (NW) FG=4957.61 25.39 LF 12" HDPE @ 0.20% HEADWALL 1-1.4B INV. IN=4952.87 (SW) FG=4952.87 OUTLET 1-1.4A INV. OUT=4952.77 (SE) FG=4952.77 30.31 LF 12" HDPE @ 11.53% STMH 1-1.4 INV. IN=4949.08 (NE) INV. IN=4949.28 (NW) INV. OUT=4949.08 (SW) FG=4959.11 PROPOSED GATE & KNOX BOX PROPOSED RETAINING WALL 6' SIDEWALK EASEMENTS REC. NO. 20100053124 PROPOSED DRAINAGE & UTILITY EASEMENT REC. NO. 20100053124 TO BE VACATED PROPOSED 10' TRAIL PROPOSED 10' TRAIL 24' E.A.E. & D.E. 24' E.A.E. & D.E. STMH 6-7 INV. IN=4948.95 (N) INV. OUT=4948.95 (W) FG=4958.80 STMH 6-8 INV. IN=4949.09 (N) INV. OUT=4949.09 (S) FG=4957.91 INLET 6-11 INV. OUT=4949.26 (S) FG=4957.25 71.77 LF 12" RCP @ 0.20% 68.03 LF 12" RCP @ 0.20% PROPOSED STORMTECH MC4500 DETENTION CHAMBERS STMH 1-6.1B INV. IN=4951.23 (N) INV. OUT=4951.23 (W) FG=4958.70 15.70 LF 18" RCP @ 8.92% 48.27 LF 18" RCP @ 9.00% OUTLET 1-6.2B INV. OUT=4955.57 (S) FG=4955.57 INLET 1-5A-2 INV. IN=4950.66 (NE) INV. OUT=4950.66 (SE) FG=4956.41 PROPOSED SIDEWALK CULVERT STMH 1-5.1A-1 INV. IN=4950.61 (SE) INV. OUT=4950.61 (SW) FG=4957.37 STMH 1-1.1 INV. IN=4947.39 (NE) INV. IN=4952.85 (N) INV. OUT=4947.39 (W) FG=4958.45 STMH 1-1.3B INV. IN=4951.31 (SW) INV. IN=4951.15 (NW) INV. OUT=4951.15 (SE) FG=4958.25 STMH 1-1.4D INV. IN=4952.99 (SE) INV. IN=4952.99 (NW) INV. OUT=4952.99 (NE) FG=4957.72 STMH 1-1.4C INV. IN=4952.93 (SW) INV. OUT=4952.93 (NE) FG=4958.48 CHBR 1-1.4D-1 INV. OUT=4953.10 (SE) FG=4957.98 31.67 LF 12" HDPE @ 0.20% 158.16 LF 24" RCP @ 0.20% STMH 1-5A-3 INV. OUT=4950.84 (NW) FG=4957.07 42.61 LF 15" RCP @ 0.87% REDWOOD POND OUTLET PIPE REDWOOD POND & THE RETREAT OUTLET PIPE IRRIGATION SERVICE (TYP.) CHMB 6-10 INV. IN=4949.16 (N) INV. OUT=4949.16 (S) FG=4957.55 25.43 LF 12" RCP @ 0.38% CHMB 6-9 INV. IN=4949.15 (N) INV. OUT=4949.15 (S) FG=4957.85 6.71 LF 12" RCP @ 0.94% 8 " P V C W A T E R STMH 1-1 INV. IN=4947.25 (N) INV. IN=4947.25 (E) INV. OUT=4947.25 (S) FG=4960.09 CHBR 1-1.3E INV. IN=4951.13 (NW) INV. OUT=4951.13 (SW) FG=4958.16 9.80 LF 12" HDPE @ 0.20% Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C3.02 UTILITY PLANS 7 REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE MATCHLINE-SEE SHEET C3.01 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE CONTROL IRR PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN SD 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E. = UTILITY EASEMENT D.E. = DRAINAGE EASEMENT NOTES: PROPOSED FIRE SERVICE F PROPOSED ELECTRIC E T PROPOSED TRANSFORMER MATCHLINE-SEE SHEET C3.03 MATCHLINE-SEE SHEET C3.04 C3.01 C3.02 C3.03 C3.04 NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 S S W F S V.P. V.P. D H2O D V.P. F E S F E S MH ELEC MH D MW MW H2O WV WV WV W H2O MW W h2o D VAULT CABLE D D IRR D D ELEC VAULT ELEC H2O VAULT ELEC H2O D WV WV WV WV H Y D D D VAULT ELEC S S WV WV WV S C C W C WV WV D 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 60" W 42" W 42" W 42" W 42" W 42" W 42" W 42" W 42" W 42" W CTV CTV CTV CTV CTV E E E E E E E E E E E E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E E E E OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU CTV CTV CTV E E E E W W W W W W W CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E E E E W W W W W W W W W W W W W W W W W W W W W CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV W W W W W CTV CTV CTV CTV CTV X X X X G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST util D FIRE HYDRANT 56' E.A.E., U.E. & D.E. 57' ACC., E.A.E, U.E. & D.E. 36' FL-FL 57' ACC., E.A.E., STMH 1-4 INV. IN=4948.80 (NE) INV. OUT=4948.80 (S) FG=4958.68 STMH 1-3 INV. IN=4948.24 (N) INV. OUT=4948.24 (S) FG=4958.28 STMH 1-2 INV. IN=4947.59 (N) INV. OUT=4947.59 (S) FG=4956.19 132.44 LF 48" RCP @ 0.49% 114.14 LF 48" RCP @ 0.49% 163.32 LF 48" RCP @ 0.49% 49.51 LF 48" RCP @ 0.97% SSMH A5 INV. IN=4943.45 (NE) INV. OUT=4943.25 (SW) FG=4958.28 SSMH A3 INV. IN=4941.85 (N) INV. OUT=4941.65 (SW) FG=4961.28 LIFT STATION A2 (PRIVATELY OWNED & MAINTAINED) INV. IN=4940.80 (NE) INV. OUT=4954.86 (W) FG=4959.94 SSMH A1 INV. IN=4953.66 (E) INV. IN=4953.46 (N) INV. OUT=4953.46 (S) FG=4959.90 SSMH A5-2 INV. OUT=4949.58 (E) FG=4961.00 73.31 LF 8" PVC @ 0.40% 296.88 LF 8" PVC @ 0.40% 177.42 LF 8" PVC @ 0.51% 213.08 LF 8" PVC @ 0.40% OWNER ROCKY MOUNTAIN RAPTOR PROGRAM REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 34.31 LF 12" HDPE @ 3.23% 64.84 LF 24" RCP @ 0.22% FEMA HIGH RISK FLOODWAY EXISTING 42" WATER LINE (ELCO/NWCWD) EXISTING 60" WATER LINE (CITY OF GREELEY) EXISTING 12" PVC WATER LINE (CoFC) (TO REMAIN) EXISTING 54" RCP STORM DRAIN (NECCO) 69.90 LF 48" RCP @ 0.49% FEMA HIGH RISK 100-YR FLOODPLAIN FUTURE CULVERT CROSSING (BY OTHERS) INLET 6-3.2 INV. OUT=4948.28 (N) FG=4959.63 CHBR 6-3 INV. IN=4948.27 (E) INV. IN=4948.21 (N) INV. OUT=4948.21 (S) FG=4959.96 STMH 6-2 INV. IN=4948.12 (N) INV. OUT=4948.12 (W) FG=4960.60 STMH 6-1 INV. IN=4947.80 (E) INV. OUT=4947.80 (S) FG=4961.58 CONNECT TO EXISTING STRM MH INV. IN=4947.64 (N) FG=4960.82 25.61 LF 12" HDPE @ 0.35% 64.03 LF 15" RCP @ 0.50% 32.02 LF 15" RCP @ 0.50% STMH 1 INV. IN=4946.77 (N) INV. OUT=4946.77 (SE) FG=4961.19 CONNECT TO BOX CULVERT INV. IN=4946.54 (NW) FG=??? 23.28 LF 48" RCP @ 0.97% 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 6' SIDEWALK 6' SIDEWALK 4.5' SIDEWALK CONNECT TO EXISTING WATER EXISTING FIRE HYDRANT CONNECT TO EXISTING SANITARY EXISTING 15" CLAY SANITARY SEWER EXISTING 12" WATER LINE 36' ACC., U.E., D.E. 20' FL-FL SSMH A4 INV. IN=4942.96 (W) INV. IN=4942.96 (NE) INV. OUT=4942.76 (S) FG=4958.76 LAKE CANAL CENTER LINE PROPOSED STORMTECH MC4500 DETENTION CHAMBERS STREET A (PRIVATE STREET) STREET E (PRIVATE STREET) REDWOOD STREET FUTURE SUNIGA DRIVE (BY OTHERS) 230.77 LF 8" PVC @ 2.00% SSMH A5-1 INV. IN=4944.96 (W) INV. OUT=4944.76 (E) FG=4959.53 90.10 LF 8" PVC @ 2.00% OUTLET 1-1.1a INV. OUT=4953.96 (S) FG=4953.99 36' FL-FL BLDG V BLDG U BLDG T BLDG S BLDG W BLDG Y BLDG X BLDG Z 24' EOP-EOP (TEMPORARY ACCESS) PROPOSED GATE & KNOX BOX 115' ROW OUTLET 1-5.2 INV. OUT=4953.19 (NE) FG=4953.19 31.37 LF 12" RCP @ 8.30% STMH 1-5.1 INV. IN=4950.59 (SW) INV. IN=4950.59 (NE) INV. OUT=4950.59 (NW) FG=4957.37 6' SIDEWALK EASEMENT REC. NO. 20100082084 EASEMENTS REC. NO. 20100053124 SLOPE &UTILITY EASEMENT REC. NO. 20170061770 DRAINAGE & UTILITY EASEMENT, REC. NO. 20170061770 6' SIDEWALK 6' SIDEWALK TRACT B STMH 6-3.1 INV. IN=4948.25 (E) INV. IN=4948.25 (S) INV. OUT=4948.25 (N) FG=4959.66 CHBR 6-4 INV. IN=4948.37 (N) INV. OUT=4948.37 (W) FG=4959.60 STMH 6-5 INV. IN=4948.50 (E) INV. OUT=4948.50 (S) FG=4960.33 STMH 6-7 INV. IN=4948.95 (N) INV. OUT=4948.95 (W) FG=4958.80 STMH 6-6 INV. IN=4948.81 (E) INV. OUT=4948.81 (W) FG=4959.31 STMH 6-8 INV. IN=4949.09 (N) INV. OUT=4949.09 (S) FG=4957.91 INLET 6-11 INV. OUT=4949.26 (S) FG=4957.25 71.77 LF 12" RCP @ 0.20% 68.03 LF 12" RCP @ 0.20% PROPOSED STORMTECH MC4500 DETENTION CHAMBERS 8' SIDEWALK REMOVE PLUG AND CONNECT TO EXISTING 8" STUB EXISTING 8" WATER EXISTING 8" SANITARY PROPOSED SIDEWALK CULVERT STMH 1-1.1 INV. IN=4947.39 (NE) INV. IN=4952.85 (N) INV. OUT=4947.39 (W) FG=4958.45 16.34 LF 12" RCP @ 0.20% 147.64 LF 12" RCP @ 0.20% 65.98 LF 12" RCP @ 0.20% PRIVATE MANHOLE PRIVATE MANHOLE CHMB 6-10 INV. IN=4949.16 (N) INV. OUT=4949.16 (S) FG=4957.55 25.43 LF 12" RCP @ 0.38% CHMB 6-9 INV. IN=4949.15 (N) INV. OUT=4949.15 (S) FG=4957.85 6.71 LF 12" RCP @ 0.94% 8" PVC WATER 8" PVC WATER 8 " P V C W A T E R STMH 1-1 INV. IN=4947.25 (N) INV. IN=4947.25 (E) INV. OUT=4947.25 (S) FG=4960.09 Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C3.01 UTILITY PLANS 6 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE CONTROL IRR PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN SD 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E. = UTILITY EASEMENT D.E. = DRAINAGE EASEMENT NOTES: PROPOSED FIRE SERVICE F PROPOSED ELECTRIC E T PROPOSED TRANSFORMER REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE MATCHLINE-SEE SHEET C3.02 MATCHLINE-SEE SHEET C3.02 C3.01 C3.02 C3.03 C3.04 NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 H2O VAULT ELEC H2O D WV WV WV WV H Y D D D VAULT ELEC D C D H Y D WV S H Y D WV WV S S S S WV WV WV S CC C C W C WV WV D 12" W 12" W 12" W 60" W 60" W 60" W 60" W 42" W 42" W 42" W CTV CTV E E E E E E E E E E CTV CTV CTV CTV CTV CTV E E E E OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU CTV CTV CTV E E W W CTV CTV CTV CTV E E E E E E CTV CTV CTV CTV CTV W W W W W W W W W W W CTV CTV CTV CTV CTV CTV CTV CTV W W CTV CTV X X SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST u til VAULT ELEC CABLE C VAULT VAULT D ELEC CABLE T ST ST ST D (13) SPACES (16) SPACES (13) SPACES (15) SPACES (12) SPACES (9) SPACES UP TYP. UP ELEVATOR TYP. TYP. H.C. SPACE UP 42" HIGH CHAIN LINK FENCE BARRIER (TYP.) 42" HIGH CHAIN LINK FENCE ENCLOSURE (TYP.) STORAGE AREA BELOW RAMP T NY LOPLA S TCUD ELI NORI T S L OPLA Y N D U C T I IEL R NO S T OPLA NYL D U TC IELI OR N NY LOPLA ST TCUD ELI NORI FIRE HYDRANT FIRE HYDRANT FIRE HYDRANT FIRE HYDRANT REMOVE PLUG CONNECT TO EXISTING 8" STUB STREET A STREET A STREET B STREET G LUPINE DRIVE STREET C MULLEIN DRIVE STREET E REDWOOD STREET FUTURE NORTHFIELD SUBDIVISION 1ST FILING REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 TRACT A REPLAT OF EVERGREEN PARK 2ND FILING LAKE CANAL LAKE CANAL OWNER ROCKY MOUNTAIN RAPTOR PROGRAM EVERGREEN PARK 3RD FILING OWNER BOARD OF COUNTY COMMISSIONERS FUTURE NORTHFIELD SUBDIVISION 1ST FILING 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY PROPOSED CONNECT TO LIFT STATION EXISTING SANITARY EXISTING 15" CLAY SANITARY SEWER FEMA HIGH RISK FLOODWAY FEMA HIGH RISK 100-YR FLOODPLAIN CONNECT TO EXISTING 12" WATER LINE FIRE HYDRANT FUTURE CULVERT CROSSING (BY OTHERS) FIRE HYDRANT FIRE HYDRANT PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED POND OUTLET PROPOSED DETENTION CHAMBERS PROPOSED DETENTION CHAMBERS PROPOSED DETENTION CHAMBERS PROPOSED DETENTION CHAMBERS DETENTION POND 2 DETENTION POND 1 EXISTING 54" NECCO STORM DRAIN EXISTING STORM DRAIN EXISTING STORM DRAIN TRACT A 8" PVC SANITARY 8" PVC WATER PROPOSED STORM DRAIN 8" PVC WATER PROPOSED POND OUTLET 8" PVC SANITARY 8" PVC WATER EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT 8" PVC WATER 8" PVC SANITARY 8" PVC WATER 8" PVC SANITARY 8 " P V C W A T E R 8 " P V C W A T E R FIRE HYDRANT PROPOSED STORM DRAIN REMOVE PLUG CONNECT TO EXISTING 8" STUB BLDG V BLDG U BLDG T BLDG S BLDG W BLDG Y BLDG X BLDG Z BLDG AA BLDG R BLDG Q BLDG BB BLDG CC BLDG P BLDG O BLDG N CLUBHOUSE BLDG M BLDG L BLDG K BLDG J BLDG I BLDG H BLDG SS BLDG RR BLDG QQ BLDG TT BLDG G BLDG F BLDG E BLDG C BLDG D BLDG B BLDG NN BLDG PP BLDG OO BLDG MM BLDG A BLDG LL BLDG KK BLDG II BLDG JJ BLDG GG BLDG HH BLDG FF BLDG EE BLDG DD POOL AREA PROPOSED POND OUTLET EXISTING 42" WATERLINE TO REMAIN (ELCO/NWCWD) EXISTING 12" WATERLINE TO REMAIN (CITY OF FORT COLLINS) EXISTING 60" WATERLINE TO REMAIN (CITY OF GREELEY) 8" PVC SANITARY 8" PVC WATER CONIFER STREET FUTURE SUNIGA DRIVE (BY OTHERS) TEMPORARY ACCESS PROPOSED POND OUTLET PROPOSED POND OUTLET PROPOSED STORM DRAIN STREET B TRACT B PROPOSED DETENTION CHAMBERS PROPOSED DETENTION CHAMBERS 8" PVC WATER Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C3.00 OVERALL UTILITY PLAN 5 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE CONTROL IRR PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN SD 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH. 6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO STREET CONSTRUCTION. 7. ABBREVIATIONS: ACC.= ACCESS EASEMENT E.A.E= EMERGENCY ACCESS EASEMENT U.E. = UTILITY EASEMENT D.E. = DRAINAGE EASEMENT NOTES: PROPOSED FIRE SERVICE F PROPOSED ELECTRIC E T PROPOSED TRANSFORMER REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE C3.01 C3.02 C3.03 C3.04 NORTH ( IN FEET ) 1 inch = ft. 100 0 100 Feet 100 200 300 H2O VAULT ELEC H2O D WV WV WV WV H Y D D D VAULT ELEC D C D H Y D WV S H Y D WV WV S S S S WV WV WV S CC C C W C WV WV D 12" W 12" W 12" W 60" W 60" W 60" W 60" W 42" W 42" W 42" W CTV CTV E E E E E E E E E E CTV CTV CTV CTV CTV CTV E E E E OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU CTV CTV CTV E E W W CTV CTV CTV CTV E E E E E E CTV CTV CTV CTV CTV W W W W W W W W W W W CTV CTV CTV CTV CTV CTV CTV CTV W W CTV CTV X X SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST u til VAULT ELEC CABLE C VAULT VAULT D ELEC CABLE T ST ST ST D (13) SPACES (16) SPACES (13) SPACES (15) SPACES (12) SPACES (9) SPACES UP TYP. UP ELEVATOR TYP. TYP. H.C. SPACE UP 42" HIGH CHAIN LINK FENCE BARRIER (TYP.) 42" HIGH CHAIN LINK FENCE ENCLOSURE (TYP.) STORAGE AREA BELOW RAMP T NY LOPLA S TCUD ELI NORI T S L OPLA Y N D U C T I IEL R NO S T OPLA NYL D U TC IELI OR N NY LOPLA ST TCUD ELI NORI REMOVE PLUG CONNECT TO EXISTING 8" STUB (PHASE 1) STREET A STREET A STREET B STREET B LUPINE DRIVE STREET C MULLEIN DRIVE STREET E REDWOOD STREET FUTURE NORTHFIELD SUBDIVISION 1ST FILING REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 TRACT A REPLAT OF EVERGREEN PARK 2ND FILING LAKE CANAL LAKE CANAL OWNER ROCKY MOUNTAIN RAPTOR PROGRAM EVERGREEN PARK 3RD FILING OWNER BOARD OF COUNTY COMMISSIONERS FUTURE NORTHFIELD SUBDIVISION 1ST FILING PROPOSED LIFT STATION (PHASE 1) CONNECT TO EXISTING SANITARY (PHASE 1) FEMA HIGH RISK FLOODWAY FEMA HIGH RISK 100-YR FLOODPLAIN CONNECT TO EXISTING 12" WATER LINE (PHASE 1) PROPOSED STORM DRAIN (PHASE 1) PROPOSED STORM DRAIN (PHASE 1) PROPOSED STORM DRAIN (PHASE 1) PROPOSED STORMTECH CHAMBERS (PHASE 1) PROPOSED STORMTECH CHAMBERS (PHASE 1) PROPOSED STORMTECH CHAMBERS (PHASE 1) DETENTION POND 2 (PHASE 1) DETENTION POND 1 (PHASE 1) TRACT A PROPOSED POND OUTLET (PHASE 1) REMOVE PLUG CONNECT TO EXISTING 8" STUB (PHASE 1) BLDG V BLDG U BLDG T BLDG S BLDG W BLDG Y BLDG X BLDG Z BLDG AA BLDG R BLDG Q BLDG BB BLDG CC BLDG P BLDG O BLDG N CLUBHOUSE BLDG M BLDG L BLDG K BLDG J BLDG I BLDG H BLDG SS BLDG RR BLDG QQ BLDG TT BLDG G BLDG F BLDG E BLDG C BLDG D BLDG B BLDG NN BLDG PP BLDG OO BLDG MM BLDG A BLDG LL BLDG KK BLDG II BLDG JJ BLDG GG BLDG HH BLDG FF BLDG EE BLDG DD CONIFER STREET PHASE 1 PHASE 2 8" PVC SANITARY (PHASE 1) 8" PVC SANITARY (PHASE 1) PROPOSED SANITARY MANHOLE (PHASE 1) 8" PVC SANITARY (PHASE 1) 8" PVC SANITARY (PHASE 2) INSTALL F.H. FOR TEMP. BLOWOFF (PHASE 1) INSTALL F.H. FOR TEMP. BLOWOFF (PHASE 1) PROPOSED STORMTECH CHAMBERS (PHASE 1) PROPOSED STORMTECH CHAMBERS (PHASE 1) PROPOSED STORM DRAIN (PHASE 2) PROPOSED POND OUTLET (PHASE 1) PROPOSED POND OUTLET (PHASE 1) 8" PVC WATER (PHASE 2) 8" PVC WATER (PHASE 1) 8" PVC WATER (PHASE 1) 8" PVC WATER (PHASE 2) 8" PVC SANITARY (PHASE 2) 8" PVC SANITARY (PHASE 1) 8" PVC WATER (PHASE 1) 8" PVC WATER (PHASE 1) 8" PVC SANITARY (PHASE 1) 8" PVC WATER (PHASE 1) PROPOSED POND OUTLET (PHASE 1) PROPOSED POND OUTLET (PHASE 1) FUTURE SUNIGA DRIVE (BY OTHERS) 8" PVC WATER PROPOSED STORMTECH CHAMBERS (PHASE 1) PARKING STRUCTURE (PHASE 1) Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 C1.01 OVERALL PHASING PLAN 4 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE NORTH ( IN FEET ) 1 inch = ft. 100 0 100 Feet 100 200 300 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY NOTES: EXISTING EDGE OF ASPHALT / / / / / / / / EXISTING RAW WATER RW EXISTING CTV CTV FUTURE CURB & GUTTER PROPOSED SWALE 1. PHASE LINES SHOWN DELINEATE THE LOTS AND/OR AREAS THAT ARE INCLUDED WITHIN A PHASE. DEPENDING ON CONSTRUCTION SEQUENCING, INSTALLATION OF INFRASTRUCTURE OUTSIDE THE LIMITS OF THE PHASE MAY BE REQUIRED. 2. THE PHASING DESIGNATIONS SHOWN ARE FOR REFERENCE ONLY, AND MAY NOT HAVE ANY RELATIONSHIP TO THE ACTUAL ORDER OF CONSTRUCTION. 3. DEPENDING ON CONSTRUCTION SEQUENCING, PREVIOUSLY CONSTRUCTED ROADWAYS MAY REQUIRE SAWCUTS, MILLING AND/OR PATCHING OF ASPHALT. FINAL LIMITS WILL BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL PATCHING AND STREET REPAIRS SHALL BE IN ACCORDANCE WITH TOWN STANDARDS. 4. INTERSECTING STREET STUBS (FUTURE FILINGS AND PHASES) AND FUTURE PHASE/FILING STREET EXTENSIONS WILL REQUIRE CLOSURE TO PUBLIC ACCESS VIA BARRICADES AT ALL SUCH LOCATIONS. 5. A TEMPORARY ACCESS ROAD APPROVED BY THE FIRE DISTRICT MUST BE BUILT WITH ALL PHASES PROVIDING SECONDARY ACCESS TO THE SITE. 6. ALL UTILITIES SHALL BE STUBBED TO THE PROCEEDING PHASE WITH TEMPORARY FIRE HYDRANTS FOR WATERLINES AND CONSTRUCTION OF THE NEAREST UPSTREAM SANITARY MANHOLE FOR SANITARY SEWER MAIN LINES. 7. WATER LOOPING AND TEMPORARY GRAVEL ACCESS ROAD CONNECTIONS ARE REQUIRED FOR ANY DEAD END ROAD LONGER THAN 660'. 8. SEE LANDSCAPE AND EROSION CONTROL PLANS FOR SEEDING/PLANTING, REVEGITATION, EROSION CONTROL FABRIC/BLANKETS, IRRIGATION AND OTHER TEMPORARY/PERMANENT SITE STABILIZATION METHODS. END OF PHASE ROADWAY AND UTILITY TERMINATIONS W W W W SS SS SS SS SS PROPOSED PHASE LINE ELEC VAULT ELEC H2O VAULT ELEC H2O D WV WV WV WV H Y D D D VAULT ELEC D VAULT CABLE C C D D H Y D WV S H Y D WV WV S S S S WV WV WV S CC C C W C WV WV D 12" W 12" W 12" W 60" W 60" W 60" W 60" W 42" W 42" W 42" W CTV CTV E E E E E E E E E E CTV CTV CTV CTV CTV CTV E E E E OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU CTV CTV CTV E E W W CTV CTV CTV CTV E E E E E E CTV CTV CTV CTV CTV W W W W W W W W W W W CTV CTV CTV CTV CTV CTV CTV CTV W W CTV CTV X X SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST u til VAULT ELEC CABLE C VAULT VAULT D ELEC CABLE T ST ST ST D STM MH EXISTING STORM PIPE TO BE REMOVED EXISTING BARRICADE MARKERS TO BE REMOVED EXISTING 18" RCP STORM TO REMAIN EXISTING 4" RCP STORM TO REMAIN EXISTING RCP STORM TO REMAIN EXISTING 15" CLAY SANITARY SEWER TO REMAIN EXISTING 24" RCP STORM TO REMAIN EXISTING R.O.W TO BE VACATED EXISTING R.O.W TO BE VACATED EXISTING PROPERTY BOUNDARY TO BE VACATED EXISTING PROPERTY BOUNDARY TO BE VACATED EXISTING R.O.W TO BE VACATED PROJECT BOUNDARY (TYP.) EXISTING 15" CLAY SANITARY SEWER TO REMAIN SOUTH LINE OF REC. NO. 19900039473 55' WIDE STRIP TO THE CITY OF FORT COLLINS EXISTING REFLECTOR SIGNS TO BE REMOVED EXISTING STORM FES TO BE REMOVED EXISTING CONCRETE PAN TO BE REMOVED EXISTING 8" PVC SANITARY SEWER TO REMAIN EXISTING 8" D.I.P WATER TO REMAIN EXISTING FIRE HYDRANT EXISTING 36' FL-FL TO REMAIN EXISTING 8" PVC SANITARY SEWER TO REMAIN EXISTING 72" CMP STORM TO REMAIN EXISTING CONCRETE HEADWALL TO REMAIN EXISTING 3 - 24" RCP STORM TO REMAIN EXISTING CONCRETE HEADWALL TO BE REMOVED AND REPLACED EXISTING 28' FL-FL TO REMAIN 50' DITCH & DRAINAGE EASEMENT BOOK 2285 PAGE 1285 TO BE RE-PLATTED DITCH & DRAINAGE EASEMENT BOOK 2285 PAGE 1285 TO BE RE-PLATTED EXISTING 114.98' ROW EXISTING 18" CMP STORM TO REMAIN FUTURE NORTHFIELD SUBDIVISION 1ST FILING REDWOOD STREET MULLEIN DRIVE BELLFLOWER DRIVE REPLAT OF THE MEADOWS AT REDWOOD P.U.D PHASE 1 TRACT A REPLAT OF EVERGREEN PARK 2ND FILING 24' ACCESS & UTILITY EASEMENT BOOK 2285 PAGE 1285 TO BE VACATED LAKE CANAL LAKE CANAL OWNER ROCKY MOUNTAIN RAPTOR PROGRAM EVERGREEN PARK 3RD FILING OWNER BOARD OF COUNTY COMMISSIONERS EXISTING 24"X18" HERCP STORM TO REMAIN EXISTING FIRE HYDRANT TO REMAIN EXISTING RCP STORM TO REMAIN EXISTING STORM INLET TO REMAIN LUPINE DRIVE FUTURE NORTHFIELD SUBDIVISION 1ST FILING FUTURE SUNIGA DRIVE PROJECT BOUNDARY (TYP.) PROPERTY CORNERS (TYP.) EASEMENT REC. NO. 20100082084 EASEMENTS REC. NO. 20100053124 SLOPE &UTILITY EASEMENT REC. NO. 20170061770 DRAINAGE & UTILITY EASEMENT, REC. NO. 20170061770 PARCEL 1 27.50' ELECTRIC EASEMENT BK 2285 PG 1285 EXCEPTED PARCEL REC. NO. 20170061770 (HATCHED AREA) PROPOSED DRAINAGE & UTILITY EASEMENT REC. NO. 20100053124 TO BE VACATED PARCEL 2 FEMA HIGH RISK 100-YR FLOODPLAIN EXISTING 6" D.I.P WATER STUB TO REMAIN EXISTING 8" D.I.P WATER PLUG TO BE REMOVED EXISTING DIRT ACCESS ROAD TO BE REMOVED AS NEEDED SUNDROP CIRCLE GINSENG CIRCLE MULLEIN DRIVE EXISTING 42" WATERLINE TO REMAIN (ELCO/NWCWD) EXISTING 12" WATER LINE FEMA HIGH RISK FLOODWAY EXISTING FIRE HYDRANT 50' CANAL BUFFER EXISTING 12" WATERLINE TO REMAIN (CITY OF FORT COLLINS) EXISTING 60" WATERLINE TO REMAIN (CITY OF GREELEY) EXISTING 54" NECCO STORM DRAIN TO REMAIN EXISTING 12" RCP TO BE EXTENDED ±73' CURB & GUTTER TO BE REMOVED ±57' CURB & GUTTER TO BE REMOVED CITY OF FORT COLLINS CONIFER STREET EXISTING SIGN, LIGHT POLE & ELECTRIC VAULT (TO BE RELOCATED BEHIND PROPOSED SIDEWALK) EXISTING CABLE BOX (TO BE RELOCATED BEHIND PROPOSED SIDEWALK) EXISTING 12" WATERLINE TO REMAIN (CITY OF FORT COLLINS) NORTH C1.00 DEMOLITION PLAN EXISTING CONDITIONS & 3 Sheet THE RETREATE AT FORT COLLINS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 24 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR FIELD SURVEY BY: NOTES: ORIGINAL FIELD SURVEY NORTHERN ENGINEERING SERVICES, INC NE PROJECT NO. 1290-002 DATE: JULY 18, 2017 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, SIDEWALKS, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 3. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING ASPHALT & CONCRETE TO BE REMOVED FEMA HIGH RISK 100-YR FLOODPLAIN FEMA HIGH RISK FLOOWAY CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner REDWOOD STREET KEYMAP C S IRR W util w w w w SUNIGA DRIVE ( IN FEET ) 1 inch = ft. 100 0 100 Feet 100 200 300 C1.00 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Preliminary Drainage Report for The Retreat at Fort Collins dated June 6, 2018 by Northern Engineering Services, Inc., shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the City of Fort Collins Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD 88 BENCHMARK #1: City of Fort Collins Benchmark Z 401: In the South edge of a Highline Tower footing at the Northwest corner of East Vine Drive and Linden Street. Elevation: 4962.74 (NAVD 88 Datum) BENCHMARK #2: City of Fort Collins Benchmark 43-97: On the South end of the West headwall of the Lake Canal Bridge at North Lemay Ave., 200 feet South of the intersection of Lemay Ave. and Conifer st. Elevation: 4960.11 (NAVD 88 Datum) Note: If NGVD29 unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 unadjusted = NAVD88 - 3.17. Basis of Bearings: The basis of bearings is the East line of the Southeast Quarter of Section 1, Township 7 North, Range 69 West of the 6th p.m. as bearing South 00°33'43" West. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: N.A. CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Preliminary Drainage Report for The Retreat at Fort Collins dated June 6, 2018 by Northern Engineering Services, Inc., shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal box and tracer wire test lid per City Water Detail 25. NORTH PROJECT DATUM: NAVD 88 BENCHMARK #1: City of Fort Collins Benchmark Z 401: In the South edge of a Highline Tower footing at the Northwest corner of East Vine Drive and Linden Street. Elevation: 4962.74 (NAVD 88 Datum) BENCHMARK #2: City of Fort Collins Benchmark 43-97: On the South end of the West headwall of the Lake Canal Bridge at North Lemay Ave., 200 feet South of the intersection of Lemay Ave. and Conifer st. Elevation: 4960.11 (NAVD 88 Datum) NOTE: If NGVD29 unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 unadjusted = NAVD88 - 3.17. Basis of Bearings: The basis of bearings is the East line of the Southeast Quarter of Section 1, Township 7 North, Range 69 West of the 6th p.m. as bearing South 00°33'43" West. Northern Engineering Services, Inc NE Project No. 1290-002 Date: July 18, 2017 ORIGINAL FIELD SURVEY BY: Terracon Consultants, Inc. Terracon Project No. 20175058 Date: March 7, 2018 SUBSURFACE EXPLORATION BY: PROJECT BENCHMARKS: UTILITY PLANS FOR THE RETREAT AT FORT COLLINS UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS----------------- Xcel Energy----------------------------- Stephanie Rich (970) 225-7857 ELECTRIC-------- City of Fort Collins Light & Power-- Justin Fields (970) 224-6150 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Heather McDowell (970) 224-6065 WASTEWATER--City of Fort Collins Utilities----------- Heather McDowell (970) 224-6065 STORMWATER- City of Fort Collins Utilities----------- Heather McDowell (970) 224-6065 A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO 1 CONTACT INFORMATION PROJECT TEAM: Northern Engineering Services, Inc. Nick Haws, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 Northern Engineering Services, Inc. Eric Smith, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 ENGINEER ING N O R T H E RN ENGINEER ING N O R T H E RN SITE ENGINEER SURVEYOR CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LANDSCAPE ARCHITECT Landmark Properties Andrew Young 455 Epps Bridge Parkway Suite 201 Athens, GA 30606 (706) 543-1910 DEVELOPER/APPLICANT City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner Ripley Design Inc. Linda Ripley 401 West Mountain Avenue Fort Collins, Colorado 80521 (970) 224-5828 JUNE 2018 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: SHEET INDEX TRAFFIC ENGINEER Delich Associates Matt Delich, PE 2272 Glen Haven Drive Loveland, CO 80538-4903 (970) 669-2061 GEOTECHNICAL ENGINEER Terracon Consultants, Inc. Eric D. Bernhardt, PE 1901 Sharp Point Drive, Suite C Fort Collins, Colorado 80525 (970) 484-0359 ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ OWNERS REPRESENTATIVE Williams & Associates Ellen Rodgers 2470 Daniells Bridge Road, Suite 160 Athens, GA 30606 (706) 310-0400 (ext. 20) 1 C0.00 COVER SHEET 2 C0.01 GENERAL & CONSTRUCTION NOTES 3 C1.00 EXISTING CONDITIONS & DEMOLITION PLAN 4 C1.01 OVERALL PHASING PLAN UTILITY SHEETS 5 C3.00 OVERALL UTILITY PLAN 6-9 C3.01-C3.04 UTILITY PLANS GRADING SHEETS 10 C4.00 OVERALL GRADING PLAN 11-14 C4.01-C4.04 GRADING PLANS ROADWAY SHEETS 15-16 C5.00-C5.01 STREET A PLAN & PROFILE 17-18 C5.02-C5.03 STREET B PLAN & PROFILE 19 C5.04 STREET C PLAN & PROFILE 20 C5.05 STREET G PLAN & PROFILE 21 C5.06 STREET E PLAN & PROFILE 22 C5.07 SUNIGA DRIVE PLAN & PROFILE DRAINAGE EXHIBIT 23 C6.00 DRAINAGE EXHIBIT 24 C6.01 FLOODPLAIN EXHIBIT LAKE CANAL