HomeMy WebLinkAboutSPIRIT AT THE RIVER (FORMERLY LINCOLN CORRIDOR HOTEL) - FDP - FDP180015 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTSPIRIT AT THE RIVER HOTEL FINAL DRAINAGE REPORT PREPARED FOR Spirit at the River Hotel Fort Collins, Colorado PREPARED BY Olsson Associates 1880 Fall River Drive, Suite 200 Loveland, CO 80538 970.461.7733 Contact: Mike Maurer, PE June, 2017 Olsson Project No. 017-0150 i Table of Contents 1.0 General Location and Description ...................................................................................... 1 1.1 Location ................................................................................................................... 1 1.2 Description of Property ............................................................................................. 1 1.3 Floodplain ................................................................................................................. 1 2.0 Drainage Basin and Sub-Basins ........................................................................................ 1 2.1 Major Basin Description ............................................................................................ 1 2.2 Sub-Basin Description .............................................................................................. 1 3.0 Drainage basin criteria ....................................................................................................... 2 3.1 Development Criteria Reference and Constraints ..................................................... 2 3.2 Hydrological Criteria ................................................................................................. 2 3.3 Hydraulic Criteria ...................................................................................................... 2 3.4 Floodplain Regulations Compliance ......................................................................... 2 3.5 Modifications of Criteria ............................................................................................ 3 4.0 Drainage Facility Design .................................................................................................... 3 4.1 General Concept ...................................................................................................... 3 4.2 Specific Details ......................................................................................................... 3 1. Low Impact Design ............................................................................................... 3 2. Minimum Required Storage Volume ..................................................................... 4 3. Outlet Structure and Spillway ................................................................................ 4 5.0 Conclusions ....................................................................................................................... 4 5.1 Compliance with Standards .................................................................................. 5 5.2 Drainage Concept ................................................................................................. 5 6.0 References ............................................................................................................... 5 List of Tables Table 1: Proposed Basins.………………………………………………………………………………2 Table 2: Rain Garden Parameters..…….………………………………………………………………3 Table 3: Detention Pond Parmaters…………………………………………………………………….4 ii List of Appendices Appendix A Hydrologic Calculations A.1 Imperviousness, Time of Concentration, Runoff Calculation Appendix B Hydraulic Calculations B.1 Detention Volume by the Modified FAA Method B.2 Pond Stage Storage Appendix C Referenced Information C.1 Vicinity Map C.2 NRCS Web Soil Survey C.3 FEMA Firm Map C.4 Fort Collins Floodplain map C.5 City of Fort Collins Rainfall Intensity-Duration-Frequency Curves C.6 Urban Drainage Imperviousness Values C.7 Drainage Basin Map 1.0 GENERAL LOCATION AND DESCRIPTION 1.1 Location The proposed project is located in the southeast quarter of section 12, township 7 north, range 69 west of the 6th P.M. City of Fort Collins, County of Larimer, State of Colorado. The proposed site is bordered on the north by Lincoln Avenue and on the south by the Cache La Poudre River. The proposed site property address is 301 Lincoln Avenue. 1.2 Description of Property Currently the site consists of an office building, some storage sheds, a workshop, a paved parking lot, and a gravel storage area to the south. The project will require the demolition of the existing structures, the paved parking lot and the gravel storage area. The proposed site is 4.37 acres and will consist of the construction of a hotel building, new parking lot, and detention ponds. Based on the NRCS soil survey the soil present on the site is classified as hydrologic group C. The site currently slopes to the south with an average slope of 1% to the Cache La Poudre River. Changes to the site grading are proposed to ensure proper drainage around the proposed building, and include the construction of connected detention ponds along the south edge of the property. 1.3 Floodplain Portions of the property are located within the FEMA-regulatory, Poudre River floodplain and must conform to the safety regulations of Chapter 10 of City Municipal Code. Any development in the floodplain must be preceded by an approved floodplain use permit. FEMA Approved LOMR Effective November 24, 2017, by Case no. 17-08-0075P revising FIRM Panel 08069C0979H Date: May 2, 2012 2.0 DRAINAGE BASIN AND SUB-BASINS 2.1 Major Basin Description Historically, the site drains to the south into the Cache La Poudre River by overland flow. The site historically discharges at a rate of 0.53 cfs and 5.47 cfs for the 10-year and 100-year storm events respectively. The existing drainage patterns for the land surrounding the property will not be impacted and there will be no drainage routed through the site from the surrounding properties. 2.2 Sub-Basin Description Historically, the site drains to the south into the Cache La Poudre River by overland flow. Due to the proposed site grading, the site was divided up into 10 drainage basins. Basins A through A6 include the proposed hotel building, the detention pond, rain garden, and the majority of the site. These basins drain to the detention pond located in the south portion of the site. Basin B is located in the north portion of the site, and runoff from this basin does not flow to the rain garden or detention pond due to grade ties with Lincoln Avenue. This basin drains north onto Lincoln Avenue before the runoff is collected in an existing curb inlet. 2 | P a g e Basin C is located in the south portion of the site and runoff from this basin does not flow to the rain garden or detention pond. This basin drains south towards the Cache La Poudre River. Basin D is located in the south portion of the site and includes the detention pond and rain garden. Runoff from this basin is collected in the detention pond. Basin Q10 (cfs) Q100 (cfs) A 4.75 10.78 A1 0.51 1.12 A2 0.77 1.69 A3 0.47 1.03 A4 0.57 1.25 A5 0.26 0.57 A6 0.53 1.16 B 0.50 1.41 C 0.19 1.30 D 0.29 1.74 Table 1. Proposed Basin Runoff 3.0 DRAINAGE BASIN CRITERIA 3.1 Development Criteria Reference and Constraints The design of the proposed drainage system was completed in accordance with the criteria set forth in Colorado Urban Drainage and Flood Control District Manual and the amendments that pertain to Fort Collins. 3.2 Hydrological Criteria Hydrologic calculations have been prepared in accordance with criteria set forth in Colorado Urban Drainage and Flood Control District Manual and the amendments that pertain to Fort Collins. 3.3 Hydraulic Criteria Hydraulic calculations have been prepared in accordance with the criteria set forth in Colorado Urban Drainage and Flood Control District Manual and the amendments that pertain to Fort Collins. The Colorado Urban Drainage and Flood Control District Stormwater Best Management Practice Design Workbook Rain Garden spreadsheet was used to size the rain garden that is providing the water quality treatment for the site. The City of Fort Collins Modified FAA Method spreadsheet was used to size the detention pond. 3.4 Floodplain Regulations Compliance 3 | P a g e Portions of the property are located within the FEMA-regulatory, Poudre River floodplain and must conform to the safety regulations of Chapter 10 of City Municipal Code. Any development in the floodplain must be preceded by an approved floodplain use permit. FEMA Approved LOMR Effective November 24, 2017, by Case no. 17-08-0075P revising FIRM Panel 08069C0979H Date: May 2, 2012. 3.5 Modifications of Criteria There are no modifications to the criteria for this project. 4.0 DRAINAGE FACILITY DESIGN 4.1 General Concept In the proposed developed condition, the majority of runoff generated on site will flow to the detention pond located in the south portion of the site. The water will reach the ponds by a combination of sheet flow, curb and gutter flow, and pipes to convey the runoff under the berm to the rain garden. The site is 4.37 acres and contains a proposed parking lot, the proposed building, and landscaped areas. Runoff will flow to the south portion of the parking lot where there is no curb, then proceed to flow south via 3 culverts installed through a berm into the rain garden and then into the proposed detention pond. Detained stormwater will discharge into the existing storm sewer manhole located west of the pond, and eventually into the Cache La Poudre River. 4.2 Specific Details 1. Low Impact Design The City of Fort Collins requires Low Impact Design (LID) for new projects. For this project it has been determined that a rain garden will be used to treat 100% of the impervious area excluding the undetained flow at the access drives. The rain garden was sized using the Colorado Urban Drainage and Flood Control District Stormwater Best Management Practice Design Workbook Rain Garden spreadsheet. The rain garden was designed to drain the WQCV in 12 hours. This is accomplished by installing an underdrain pipe with an orifice to control the release rate of the treated stormwater. See Appendix B for the rain garden spreadsheet. Parameter Value Bottom of Rain Garden Elevation 4943.50 Top of Rain Garden Elevation 4944.50 Required Volume of Rain Garden 1,096.8 cubic feet Provided Volume of Rain Garden 1,099.0 cubic feet Required Flat Surface Area 834 square feet Provided Flat Surface Area 838 square feet Table 2. Rain Garden Parameters Refer to the landscape plans for the planted vegetation within the rain garden. 4 | P a g e Design points were calculated with the sum of the 5 and 100-year runoff rates of the basins that contributed to those points. Design points can be found on the Drainage Basin Map located in Appendix C. 2. Minimum Required Storage Volume The minimum required storage volume was determined using The City of Fort Collins Modified FAA method spreadsheet. See Appendix B.1. The WQCV for the site was determined to be 1,444 cubic feet based on The Colorado Urban Drainage and Flood Control District Stormwater Best Management Practice Design Workbook Rain Garden spreadsheet. The WQCV will be treated using the rain garden. Parameter Value 2 yr Required Volume 2,376 cubic feet 100 yr Required Volume 31,968 cubic feet Bottom of Pond 4940.00 2 yr Provided Volume 4,091 cubic feet 2 yr WSEL 4941.25 100 yr Provided Volume 34,506 cubic feet 100 yr WSEL 4944.50 Outlet Structure Invert 4939.70 100 yr Allowable Release Rate 1.47 cfs Spillway Elevation 4944.50 Top of Pond 4945.50 Table 3. Detention Pond Parameters 3. Outlet Structure and Spillway The Outlet structure is designed to release the 100-year volume at the site’s historic 2-year runoff rate of 1.49 cfs. The bike trail to the south of the ponds will serve as the emergency spillway where excess volume will overtop the trail and discharge directly into the Cache La Poudre River. The overflow weir will be designed to be wide enough to minimize the velocities so that rip-rap protection will not be necessary. 5.0 CONCLUSIONS 5 | P a g e 5.1 Compliance with Standards This report has been prepared in accordance with common engineering practices, the criteria set forth in Colorado Urban Drainage and Flood Control District Manual and the amendments that pertain to Fort Collins. 5.2 Drainage Concept Developed runoff generated on the proposed site will be directed to the rain garden and detention pond located in the south portion of the site. The rain garden is designed to treat 100 percent of the site WQCV, and the pond outlet structure is designed to release the 100-year volume at the site’s 2-year historic runoff rate of 1.49 cfs. The raingarden outfall is designed to release the 100-year volume from the rain garden into the detention basin at 19.34 cfs. Raingarden outfall calculations can be found in Appendix A. 6.0 References Drainage Criteria Manual, Volumes 1, 2, & 3, Urban Drainage and Flood Control District, Volumes 1 & 2 – Originally Published September 1969, updated January 2016; Volume 3 – Originally Published September 1992, updated November 2010 Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual dated December 2011 6 | P a g e APPENDIX A HYDROLOGIC CALCULATIONS 1880 Fall River Drive Suite 200 Loveland, CO 80538 TEL 970.461.7733 Spirit at the River Hotel Hydrologic Calcs COMPOSITE PERCENT IMPERVIOUSNESS Paved Building Brick Pavers Landscape 90% 90% 22% 2% C 5 C 10 C 100 (acres) (acres) (acres) (acres) A Parking C 1.24 - 0.04 0.10 1.38 82% B Undetained North B 0.13 - - 0.09 0.22 53% C Undetained South C - - - 0.41 0.41 2% A1 Roof C - 0.13 - - 0.13 90% A2 Roof C - 0.20 - - 0.20 90% A3 Roof C - 0.12 - - 0.12 90% A4 Roof C - 0.15 - - 0.15 90% A5 Roof C - 0.07 - - 0.07 90% A6 Roof C - 0.14 - - 0.14 90% D Detention Pond & Rain Garden C 0.02 - - 0.58 0.60 5% Total Site Total Site C 1.39 0.80 0.04 1.17 3.41 66% 0.80 0.80 0.74 0.48 0.15 0.08 0.80 0.80 0.80 0.80 0.85 0.85 0.85 0.85 0.77 Basin Name Basin Description 0.77 0.77 0.77 0.77 Soil Type 0.71 0.45 0.05 Total Area (ac) 0.82 Percent Impervio usness 0.77 0.67 0.49 0.85 0.85 0.17 0.50 TIME OF CONCENTRATION CALCULATIONS Channel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Tuesday, Jun 12 2018 Rain Garden Outfall - Design Point 4 Circular Diameter (ft) = 2.00 Invert Elev (ft) = 4941.34 Slope (%) = 1.04 N-Value = 0.013 Calculations Compute by: Q vs Depth No. Increments = 10 Highlighted Depth (ft) = 1.40 Q (cfs) = 19.36 Area (sqft) = 2.35 Velocity (ft/s) = 8.22 Wetted Perim (ft) = 3.97 Crit Depth, Yc (ft) = 1.59 Top Width (ft) = 1.83 EGL (ft) = 2.45 0 1 2 3 4 Elev (ft) Depth (ft) Section 4940.50 -0.84 4941.00 -0.34 4941.50 0.16 4942.00 0.66 4942.50 1.16 4943.00 1.66 4943.50 2.16 4944.00 2.66 Reach (ft) 7 | P a g e APPENDIX B HYDRAULIC CALCULATIONS 100 Year This is to convert % imp. to a C value 100-year (must insert % imp. and C pervious). ft3 acre-ft. 'C' value 0.59 31968.6 0.734 'C' * 1.25 0.7375 Area 4.37 acres Modified Modified Release Rate 1.49 M. FATER D. JUDISH C. LI May-95 Nov-97 Nov-98 DETENTION POND SIZING TIME TIME INTENSITY Q 100 Runoff Release Required Required cum 100 year Volume Cum total Detention Detention (mins) (secs) (in/hr) (cfs) (ft^3) (ft^3) (ft^3) (ac-ft) 0 0 0 0.00 0 0.0 0.0 0.0000 5 300 9.950 32.07 9620.282 447.0 9173.3 0.2106 10 600 7.720 24.88 14928.36 894.0 14034.4 0.3222 15 900 6.520 21.01 18911.83 1341.0 17570.8 0.4034 20 1200 5.600 18.05 21657.72 1788.0 19869.7 0.4561 25 1500 4.980 16.05 24074.88 2235.0 21839.9 0.5014 30 1800 4.520 14.57 26221.31 2682.0 23539.3 0.5404 35 2100 4.080 13.15 27613.59 3129.0 24484.6 0.5621 40 2400 3.740 12.05 28928.53 3576.0 25352.5 0.5820 45 2700 3.460 11.15 30108.1 4023.0 26085.1 0.5988 50 3000 3.230 10.41 31229.66 4470.0 26759.7 0.6143 55 3300 3.030 9.77 32225.53 4917.0 27308.5 0.6269 60 3600 2.860 9.22 33182.72 5364.0 27818.7 0.6386 65 3900 2.720 8.77 34188.26 5811.0 28377.3 0.6515 70 4200 2.590 8.35 35058.43 6258.0 28800.4 0.6612 75 4500 2.480 7.99 35967.29 6705.0 29262.3 0.6718 80 4800 2.380 7.67 36818.12 7152.0 29666.1 0.6810 85 5100 2.290 7.38 37639.96 7599.0 30041.0 0.6896 90 5400 2.210 7.12 38461.79 8046.0 30415.8 0.6983 95 5700 2.130 6.86 39128.93 8493.0 30635.9 0.7033 100 6000 2.060 6.64 39834.74 8940.0 30894.7 0.7092 105 6300 2.000 6.45 40608.23 9387.0 31221.2 0.7167 110 6600 1.940 6.25 41265.69 9834.0 31431.7 0.7216 115 6900 1.890 6.09 42029.51 10281.0 31748.5 0.7288 120 7200 1.840 5.93 42696.65 10728.0 31968.6 0.7339 125 7500 1.790 5.77 43267.1 11175.0 32092.1 0.7367 130 7800 1.750 5.64 43992.24 11622.0 32370.2 0.7431 135 8100 1.710 5.51 44640.04 12069.0 32571.0 0.7477 140 8400 1.670 5.38 45210.49 12516.0 32694.5 0.7506 145 8700 1.630 5.25 45703.59 12963.0 32740.6 0.7516 150 9000 1.600 5.16 46409.4 13410.0 32999.4 0.7576 155 9300 1.570 5.06 47057.2 13857.0 33200.2 0.7622 160 9600 1.540 4.96 47646.98 14304.0 33343.0 0.7654 165 9900 1.510 4.87 48178.76 14751.0 33427.8 0.7674 170 10200 1.480 4.77 48652.52 15198.0 33454.5 0.7680 175 10500 1.450 4.67 49068.27 15645.0 33423.3 0.7673 180 10800 1.420 4.58 49426.01 16092.0 33334.0 0.7652 Required detention Page 1 Project: Basin ID: X 1 #1 Vertical #2 Vertical Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input) Orifice Orifice Water Surface Elevation at Design Depth Elev: WS = 4,944.50 feet Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert = 4,941.00 feet Required Peak Flow through Orifice at Design Depth Q = 14.37 cfs Pipe/Vertical Orifice Diameter (inches) Dia = 18.0 inches Orifice Coefficient Co = 0.65 Full-flow Capacity (Calculated) Full-flow area Af = 1.77 sq ft Half Central Angle in Radians Theta = 3.14 rad Full-flow capacity Qf = 15.3 cfs Percent of Design Flow = 106% Calculation of Orifice Flow Condition Half Central Angle (0<Theta<3.1416) Theta = 2.41 rad Flow area Ao = 1.63 sq ft Top width of Orifice (inches) To = 12.09 inches Height from Invert of Orifice to Bottom of Plate (feet) Yo = 1.31 feet Elevation of Bottom of Plate Elev Plate Bottom Edge = 4,942.31 feet Resultant Peak Flow Through Orifice at Design Depth Qo = 14.4 cfs Width of Equivalent Rectangular Vertical Orifice Equivalent Width = 1.24 feet Spirit at the River RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES UD-Detention_v2.34, Restrictor Plate 6/5/2018, 11:51 AM Stormwater Facility Name: Facility Location & Jurisdiction: User (Input) Watershed Characteristics User Defined User Defined User Defined User Defined Watershed Slope = 0.010 ft/ft Stage [ft] Area [ft^2] Stage [ft] Discharge [cfs] Watershed Length-to-Width Ratio = 2.00 L:W 0.00 20.99 0.00 0.08 Watershed Area = 0.19 acres 0.10 100.90 0.10 0.08 Watershed Imperviousness = 90.0% percent 0.20 288.44 0.20 0.08 Percentage Hydrologic Soil Group A = 0.0% percent 0.30 571.15 0.30 0.08 Percentage Hydrologic Soil Group B = 0.0% percent 0.40 691.89 0.40 0.08 Percentage Hydrologic Soil Groups C/D = 100.0% percent 0.50 837.53 0.50 0.08 0.60 1002.00 0.60 0.08 0.70 1153.86 0.70 0.08 0.80 1301.74 0.80 0.08 0.90 1373.59 0.90 0.08 User Input: Detention Basin Characteristics 1.00 1447.65 1.00 0.08 WQCV Design Drain Time = 12.00 hours 1.10 1528.25 1.10 0.08 1.20 1615.41 1.20 0.08 1.30 1713.88 1.30 0.08 1.40 1795.53 1.40 0.08 1.50 1878.28 1.50 0.08 1.60 1962.11 1.60 0.08 1.70 2047.03 1.70 0.08 1.80 2155.64 1.80 0.08 1.90 2250.65 1.90 0.08 2.00 2349.67 2.00 0.08 2.10 2452.72 2.10 0.08 2.20 2559.79 2.20 0.08 After completing and printing this worksheet to a pdf, go to: https://maperture.digitaldataservices.com/gvh/?viewer=cswdif, create a new stormwater facility, and attach the pdf of this worksheet to that record. Routed Hydrograph Results Design Storm Return Period = WQCV 2 Year 5 Year 10 Year 25 Year 50 Year 100 Year Two-Hour Rainfall Depth = 0.53 0.98 1.36 1.71 2.31 2.91 3.67 in Calculated Runoff Volume = 0.005 0.014 0.020 0.026 0.036 0.046 0.059 acre-ft OPTIONAL Override Runoff Volume = 0.01 0.04 0.05 acre-ft Inflow Hydrograph Volume = 0.005 0.009 0.019 0.035 0.035 0.046 0.052 acre-ft Time to Drain 97% of Inflow Volume = 1 2 3 5 5 7 8 hours Time to Drain 99% of Inflow Volume = 1 2 3 5 5 7 8 hours Maximum Ponding Depth = 0.14 0.35 0.75 1.17 1.17 1.42 1.57 ft Maximum Ponded Area = 0.004 0.014 0.028 0.036 0.036 0.042 0.044 acres Maximum Volume Stored = 0.000 0.002 0.011 0.024 0.024 0.034 0.040 acre-ft Stormwater Detention and Infiltration Design Data Sheet OSLC Detention Pond Fort Collins, CO Workbook Protected Worksheet Protected SDI_Design_Data_FC_Rainfall.xlsm, Design Data 12/12/2017, 10:13 AM Doing_Clear_Formatting Yes = CountA= 1 0 1 2 3 #N/A #N/A 0 1 2 3 #N/A #N/A Check Data Set 0 Check Data Set 1 Stormwater Detention and Infiltration Design Data Sheet Area Discharge 0 0.2 0.4 0.6 0.8 1 1.2 0.1 1 10 FLOW [cfs] TIME [hr] 100YR IN 100YR OUT 50YR IN 50YR OUT 25YR IN 25YR OUT 10YR IN 10YR OUT 5YR IN 5YR OUT 2YR IN 2YR OUT WQCV IN WQCV OUT 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 0.1 1 10 100 PONDING DEPTH [ft] DRAIN TIME [hr] 100YR 50YR 25YR 10YR 5YR 2YR WQCV SDI_Design_Data_FC_Rainfall.xlsm, Design Data 12/12/2017, 10:13 AM Project: Basin ID: Design Information (Input): Width of Basin Bottom, W = ft Right Triangle OR… Length of Basin Bottom, L = ft Isosceles Triangle OR… Dam Side-slope (H:V), Zd = ft/ft Rectangle OR… Circle / Ellipse OR… Irregular X (Use Overide values in cells G32:G52) MINOR MAJOR Storage Requirement from Sheet 'Modified FAA': 0.09 0.38 acre-ft. Stage-Storage Relationship: Storage Requirement from Sheet 'Hydrograph': acre-ft. Storage Requirement from Sheet 'Full-Spectrum': acre-ft. Labels Water Side Basin Basin Surface Surface Volume Surface Volume Target Volumes for WQCV, Minor, Surface Slope Width at Length at Area at Area at Below Area at Below for WQCV, Minor, & Major Storage Elevation (H:V) Stage Stage Stage Stage Stage Stage Stage & Major Storage Stages ft ft/ft ft ft ft2 ft2 User ft3 acres acre-ft Volumes (input) (input) Below El. (output) (output) (output) Overide (output) (output) (output) (for goal seek) 4939.75 (input) 0.21 0.000 0.000 4940.00 0.00 0.00 544.49 68 0.012 0.002 4940.25 0.00 0.00 1,703.96 349 0.039 0.008 4940.50 0.00 0.00 3,513.39 1,001 0.081 0.023 4940.75 0.00 0.00 4,655.75 2,022 0.107 0.046 4941.00 0.00 0.00 5,299.32 3,267 0.122 0.075 4941.25 0.00 0.00 5,795.98 4,654 0.133 0.107 4941.50 0.00 0.00 6,309.99 6,167 0.145 0.142 4941.75 0.00 0.00 6,833.05 7,810 0.157 0.179 4942.00 0.00 0.00 7,364.96 9,585 0.169 0.220 4942.25 0.00 0.00 7,905.71 11,493 0.181 0.264 4942.50 0.00 0.00 8,455.32 13,539 0.194 0.311 4942.75 0.00 0.00 9,013.76 15,722 0.207 0.361 4943.00 0.00 0.00 9,581.06 18,047 0.220 0.414 4943.25 0.00 0.00 10,157.20 20,514 0.233 0.471 4943.50 0.00 0.00 10,742.19 23,126 0.247 0.531 4943.75 0.00 0.00 11,336.03 25,886 0.260 0.594 4944.00 0.00 0.00 11,938.71 28,795 0.274 0.661 4944.25 0.00 0.00 12,550.24 31,857 0.288 0.731 4944.50 0.00 0.00 13,170.62 35,072 0.302 0.805 4945.00 0.00 0.00 14,616.84 42,018 0.336 0.965 4945.50 0.00 0.00 16,045.56 49,684 0.368 1.141 STAGE-STORAGE SIZING FOR DETENTION BASINS Spirit at the River Check Basin Shape UD-Detention_v2.34.xls, Basin 5/23/2018, 1:28 PM 100 YR 2 YR Sheet 1 of 2 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia Ia = 59.0 % (100% if all paved and roofed areas upstream of rain garden) B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 0.590 C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV = 0.19 watershed inches (WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i) D) Contributing Watershed Area (including rain garden area) Area = 70,656 sq ft E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = cu ft Vol = (WQCV / 12) * Area F) For Watersheds Outside of the Denver Region, Depth of d6 = 0.43 in Average Runoff Producing Storm G) For Watersheds Outside of the Denver Region, VWQCV OTHER = 1,096.8 cu ft Water Quality Capture Volume (WQCV) Design Volume H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER = cu ft (Only if a different WQCV Design Volume is desired) 2. Basin Geometry A) WQCV Depth (12-inch maximum) DWQCV = 10.5 in B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical) Z = 4.00 ft / ft (Use "0" if rain garden has vertical walls) C) Mimimum Flat Surface Area AMin = 834 sq ft D) Actual Flat Surface Area AActual = 838 sq ft E) Area at Design Depth (Top Surface Area) ATop = 1675 sq ft F) Rain Garden Total Volume VT= 1,099 cu ft (VT= ((ATop + AActual) / 2) * Depth) 3. Growing Media 4. Underdrain System A) Are underdrains provided? B) Underdrain system orifice diameter for 12 hour drain time i) Distance From Lowest Elevation of the Storage y = 1.0 ft Volume to the Center of the Orifice ii) Volume to Drain in 12 Hours Vol12 = 1,097 cu ft iii) Orifice Diameter, 3/8" Minimum DO = 7/8 in Design Procedure Form: Rain Garden (RG) Ian Swensson Olsson Assocaites June 6, 2018 Spirit at the River Hotel (017-0150) Fort Collins, CO UD-BMP (Version 3.06, November 2016) Choose One Choose One 18" Rain Garden Growing Media Other (Explain): YES NO Rain Garden Calcs, RG 6/6/2018, 2:54 PM Sheet 2 of 2 Designer: Company: Date: Project: Location: 5. Impermeable Geomembrane Liner and Geotextile Separator Fabric A) Is an impermeable liner provided due to proximity of structures or groundwater contamination? 6. Inlet / Outlet Control A) Inlet Control 7. Vegetation 8. Irrigation A) Will the rain garden be irrigated? Notes: Design Procedure Form: Rain Garden (RG) Ian Swensson Olsson Assocaites June 6, 2018 Spirit at the River Hotel (017-0150) Fort Collins, CO Choose One Choose One Choose One Sheet Flow- No Energy Dissipation Required Concentrated Flow- Energy Dissipation Provided Plantings Seed (Plan for frequent weed control) Sand Grown or Other High Infiltration Sod Choose One YES NO YES NO Rain Garden Calcs, RG 6/6/2018, 2:54 PM 8 | P a g e APPENDIX C REFERENCED INFORMATION TEL 970.431.7733 Loveland, CO 80538 Suite 160 5285 McWhinney Boulevard R 1880 Fall River Drive Vicinity Map Lincoln Ave Suite 200 Site SITE  &XVWRP6RLO5HVRXUFH5HSRUW 6RLO0DS                                     ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ  : 1 0DSSURMHFWLRQ:HE0HUFDWRU&RUQHUFRRUGLQDWHV:*6(GJHWLFV870=RQH1:*6      )HHW      0HWHUV 0DS6FDOHLISULQWHGRQ$SRUWUDLW [ 0$3/(*(1' 0$3,1)250$7,21 $UHDRI,QWHUHVW $2, $UHDRI,QWHUHVW $2, 6RLOV 6RLO0DS8QLW3RO\JRQV 6RLO0DS8QLW/LQHV 6RLO0DS8QLW3RLQWV 6SHFLDO3RLQW)HDWXUHV %ORZRXW %RUURZ3LW &OD\6SRW &ORVHG'HSUHVVLRQ *UDYHO3LW *UDYHOO\6SRW /DQGILOO /DYD)ORZ 0DUVKRUVZDPS 0LQHRU4XDUU\ 0LVFHOODQHRXV:DWHU 3HUHQQLDO:DWHU 5RFN2XWFURS 6DOLQH6SRW 6DQG\6SRW 6HYHUHO\(URGHG6SRW 6LQNKROH 6OLGHRU6OLS 6RGLF6SRW 6SRLO$UHD 6WRQ\6SRW 9HU\6WRQ\6SRW :HW6SRW 2WKHU 6SHFLDO/LQH)HDWXUHV :DWHU)HDWXUHV 6WUHDPVDQG&DQDOV 7UDQVSRUWDWLRQ 5DLOV ,QWHUVWDWH+LJKZD\V 865RXWHV 0DMRU5RDGV /RFDO5RDGV %DFNJURXQG $HULDO3KRWRJUDSK\ 7KHVRLOVXUYH\VWKDWFRPSULVH\RXU$2,ZHUHPDSSHGDW  :DUQLQJ6RLO0DSPD\QRWEHYDOLGDWWKLVVFDOH (QODUJHPHQWRIPDSVEH\RQGWKHVFDOHRIPDSSLQJFDQFDXVH PLVXQGHUVWDQGLQJRIWKHGHWDLORIPDSSLQJDQGDFFXUDF\RIVRLO OLQHSODFHPHQW7KHPDSVGRQRWVKRZWKHVPDOODUHDVRI FRQWUDVWLQJVRLOVWKDWFRXOGKDYHEHHQVKRZQDWDPRUHGHWDLOHG VFDOH 3OHDVHUHO\RQWKHEDUVFDOHRQHDFKPDSVKHHWIRUPDS PHDVXUHPHQWV 6RXUFHRI0DS 1DWXUDO5HVRXUFHV&RQVHUYDWLRQ6HUYLFH :HE6RLO6XUYH\85/ &RRUGLQDWH6\VWHP :HE0HUFDWRU (36* 0DSVIURPWKH:HE6RLO6XUYH\DUHEDVHGRQWKH:HE0HUFDWRU SURMHFWLRQZKLFKSUHVHUYHVGLUHFWLRQDQGVKDSHEXWGLVWRUWV GLVWDQFHDQGDUHD$SURMHFWLRQWKDWSUHVHUYHVDUHDVXFKDVWKH $OEHUVHTXDODUHDFRQLFSURMHFWLRQVKRXOGEHXVHGLIPRUH 0DS8QLW/HJHQG /DULPHU&RXQW\$UHD&RORUDGR &2 0DS8QLW6\PERO 0DS8QLW1DPH $FUHVLQ$2, 3HUFHQWRI$2,  /RYHODQGFOD\ORDPWR SHUFHQWVORSHV    7DEOH0RXQWDLQORDPWR SHUFHQWVORSHV   7RWDOVIRU$UHDRI,QWHUHVW   0DS8QLW'HVFULSWLRQV 7KHPDSXQLWVGHOLQHDWHGRQWKHGHWDLOHGVRLOPDSVLQDVRLOVXUYH\UHSUHVHQWWKH VRLOVRUPLVFHOODQHRXVDUHDVLQWKHVXUYH\DUHD7KHPDSXQLWGHVFULSWLRQVDORQJ ZLWKWKHPDSVFDQEHXVHGWRGHWHUPLQHWKHFRPSRVLWLRQDQGSURSHUWLHVRIDXQLW $PDSXQLWGHOLQHDWLRQRQDVRLOPDSUHSUHVHQWVDQDUHDGRPLQDWHGE\RQHRUPRUH PDMRUNLQGVRIVRLORUPLVFHOODQHRXVDUHDV$PDSXQLWLVLGHQWLILHGDQGQDPHG DFFRUGLQJWRWKHWD[RQRPLFFODVVLILFDWLRQRIWKHGRPLQDQWVRLOV:LWKLQDWD[RQRPLF FODVVWKHUHDUHSUHFLVHO\GHILQHGOLPLWVIRUWKHSURSHUWLHVRIWKHVRLOV2QWKH ODQGVFDSHKRZHYHUWKHVRLOVDUHQDWXUDOSKHQRPHQDDQGWKH\KDYHWKH FKDUDFWHULVWLFYDULDELOLW\RIDOOQDWXUDOSKHQRPHQD7KXVWKHUDQJHRIVRPH REVHUYHGSURSHUWLHVPD\H[WHQGEH\RQGWKHOLPLWVGHILQHGIRUDWD[RQRPLFFODVV $UHDVRIVRLOVRIDVLQJOHWD[RQRPLFFODVVUDUHO\LIHYHUFDQEHPDSSHGZLWKRXW LQFOXGLQJDUHDVRIRWKHUWD[RQRPLFFODVVHV&RQVHTXHQWO\HYHU\PDSXQLWLVPDGH XSRIWKHVRLOVRUPLVFHOODQHRXVDUHDVIRUZKLFKLWLVQDPHGDQGVRPHPLQRU FRPSRQHQWVWKDWEHORQJWRWD[RQRPLFFODVVHVRWKHUWKDQWKRVHRIWKHPDMRUVRLOV 0RVWPLQRUVRLOVKDYHSURSHUWLHVVLPLODUWRWKRVHRIWKHGRPLQDQWVRLORUVRLOVLQWKH PDSXQLWDQGWKXVWKH\GRQRWDIIHFWXVHDQGPDQDJHPHQW7KHVHDUHFDOOHG QRQFRQWUDVWLQJRUVLPLODUFRPSRQHQWV7KH\PD\RUPD\QRWEHPHQWLRQHGLQD SDUWLFXODUPDSXQLWGHVFULSWLRQ2WKHUPLQRUFRPSRQHQWVKRZHYHUKDYHSURSHUWLHV DQGEHKDYLRUDOFKDUDFWHULVWLFVGLYHUJHQWHQRXJKWRDIIHFWXVHRUWRUHTXLUHGLIIHUHQW PDQDJHPHQW7KHVHDUHFDOOHGFRQWUDVWLQJRUGLVVLPLODUFRPSRQHQWV7KH\ JHQHUDOO\DUHLQVPDOODUHDVDQGFRXOGQRWEHPDSSHGVHSDUDWHO\EHFDXVHRIWKH VFDOHXVHG6RPHVPDOODUHDVRIVWURQJO\FRQWUDVWLQJVRLOVRUPLVFHOODQHRXVDUHDV DUHLGHQWLILHGE\DVSHFLDOV\PERORQWKHPDSV,ILQFOXGHGLQWKHGDWDEDVHIRUD JLYHQDUHDWKHFRQWUDVWLQJPLQRUFRPSRQHQWVDUHLGHQWLILHGLQWKHPDSXQLW GHVFULSWLRQVDORQJZLWKVRPHFKDUDFWHULVWLFVRIHDFK$IHZDUHDVRIPLQRU FRPSRQHQWVPD\QRWKDYHEHHQREVHUYHGDQGFRQVHTXHQWO\WKH\DUHQRW PHQWLRQHGLQWKHGHVFULSWLRQVHVSHFLDOO\ZKHUHWKHSDWWHUQZDVVRFRPSOH[WKDWLW ZDVLPSUDFWLFDOWRPDNHHQRXJKREVHUYDWLRQVWRLGHQWLI\DOOWKHVRLOVDQG PLVFHOODQHRXVDUHDVRQWKHODQGVFDSH 7KHSUHVHQFHRIPLQRUFRPSRQHQWVLQDPDSXQLWLQQRZD\GLPLQLVKHVWKH XVHIXOQHVVRUDFFXUDF\RIWKHGDWD7KHREMHFWLYHRIPDSSLQJLVQRWWRGHOLQHDWH SXUHWD[RQRPLFFODVVHVEXWUDWKHUWRVHSDUDWHWKHODQGVFDSHLQWRODQGIRUPVRU ODQGIRUPVHJPHQWVWKDWKDYHVLPLODUXVHDQGPDQDJHPHQWUHTXLUHPHQWV7KH GHOLQHDWLRQRIVXFKVHJPHQWVRQWKHPDSSURYLGHVVXIILFLHQWLQIRUPDWLRQIRUWKH &XVWRP6RLO5HVRXUFH5HSRUW  GHYHORSPHQWRIUHVRXUFHSODQV,ILQWHQVLYHXVHRIVPDOODUHDVLVSODQQHGKRZHYHU RQVLWHLQYHVWLJDWLRQLVQHHGHGWRGHILQHDQGORFDWHWKHVRLOVDQGPLVFHOODQHRXV DUHDV $QLGHQWLI\LQJV\PEROSUHFHGHVWKHPDSXQLWQDPHLQWKHPDSXQLWGHVFULSWLRQV (DFKGHVFULSWLRQLQFOXGHVJHQHUDOIDFWVDERXWWKHXQLWDQGJLYHVLPSRUWDQWVRLO SURSHUWLHVDQGTXDOLWLHV 6RLOVWKDWKDYHSURILOHVWKDWDUHDOPRVWDOLNHPDNHXSDVRLOVHULHV([FHSWIRU GLIIHUHQFHVLQWH[WXUHRIWKHVXUIDFHOD\HUDOOWKHVRLOVRIDVHULHVKDYHPDMRU KRUL]RQVWKDWDUHVLPLODULQFRPSRVLWLRQWKLFNQHVVDQGDUUDQJHPHQW 6RLOVRIRQHVHULHVFDQGLIIHULQWH[WXUHRIWKHVXUIDFHOD\HUVORSHVWRQLQHVV VDOLQLW\GHJUHHRIHURVLRQDQGRWKHUFKDUDFWHULVWLFVWKDWDIIHFWWKHLUXVH2QWKH EDVLVRIVXFKGLIIHUHQFHVDVRLOVHULHVLVGLYLGHGLQWRVRLOSKDVHV0RVWRIWKHDUHDV VKRZQRQWKHGHWDLOHGVRLOPDSVDUHSKDVHVRIVRLOVHULHV7KHQDPHRIDVRLOSKDVH FRPPRQO\LQGLFDWHVDIHDWXUHWKDWDIIHFWVXVHRUPDQDJHPHQW)RUH[DPSOH$OSKD VLOWORDPWRSHUFHQWVORSHVLVDSKDVHRIWKH$OSKDVHULHV 6RPHPDSXQLWVDUHPDGHXSRIWZRRUPRUHPDMRUVRLOVRUPLVFHOODQHRXVDUHDV 7KHVHPDSXQLWVDUHFRPSOH[HVDVVRFLDWLRQVRUXQGLIIHUHQWLDWHGJURXSV $FRPSOH[FRQVLVWVRIWZRRUPRUHVRLOVRUPLVFHOODQHRXVDUHDVLQVXFKDQLQWULFDWH SDWWHUQRULQVXFKVPDOODUHDVWKDWWKH\FDQQRWEHVKRZQVHSDUDWHO\RQWKHPDSV 7KHSDWWHUQDQGSURSRUWLRQRIWKHVRLOVRUPLVFHOODQHRXVDUHDVDUHVRPHZKDWVLPLODU LQDOODUHDV$OSKD%HWDFRPSOH[WRSHUFHQWVORSHVLVDQH[DPSOH $QDVVRFLDWLRQLVPDGHXSRIWZRRUPRUHJHRJUDSKLFDOO\DVVRFLDWHGVRLOVRU PLVFHOODQHRXVDUHDVWKDWDUHVKRZQDVRQHXQLWRQWKHPDSV%HFDXVHRISUHVHQW RUDQWLFLSDWHGXVHVRIWKHPDSXQLWVLQWKHVXUYH\DUHDLWZDVQRWFRQVLGHUHG SUDFWLFDORUQHFHVVDU\WRPDSWKHVRLOVRUPLVFHOODQHRXVDUHDVVHSDUDWHO\7KH SDWWHUQDQGUHODWLYHSURSRUWLRQRIWKHVRLOVRUPLVFHOODQHRXVDUHDVDUHVRPHZKDW VLPLODU$OSKD%HWDDVVRFLDWLRQWRSHUFHQWVORSHVLVDQH[DPSOH $QXQGLIIHUHQWLDWHGJURXSLVPDGHXSRIWZRRUPRUHVRLOVRUPLVFHOODQHRXVDUHDV WKDWFRXOGEHPDSSHGLQGLYLGXDOO\EXWDUHPDSSHGDVRQHXQLWEHFDXVHVLPLODU LQWHUSUHWDWLRQVFDQEHPDGHIRUXVHDQGPDQDJHPHQW7KHSDWWHUQDQGSURSRUWLRQ RIWKHVRLOVRUPLVFHOODQHRXVDUHDVLQDPDSSHGDUHDDUHQRWXQLIRUP$QDUHDFDQ EHPDGHXSRIRQO\RQHRIWKHPDMRUVRLOVRUPLVFHOODQHRXVDUHDVRULWFDQEHPDGH XSRIDOORIWKHP$OSKDDQG%HWDVRLOVWRSHUFHQWVORSHVLVDQH[DPSOH 6RPHVXUYH\VLQFOXGHPLVFHOODQHRXVDUHDV6XFKDUHDVKDYHOLWWOHRUQRVRLO PDWHULDODQGVXSSRUWOLWWOHRUQRYHJHWDWLRQ5RFNRXWFURSLVDQH[DPSOH &XVWRP6RLO5HVRXUFH5HSRUW  /DULPHU&RXQW\$UHD&RORUDGR ²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²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².)DFWRU:KROH6RLO .)DFWRU                                     ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ  : 1 0DSSURMHFWLRQ:HE0HUFDWRU&RUQHUFRRUGLQDWHV:*6(GJHWLFV870=RQH1:*6      )HHW      0HWHUV 0DS6FDOHLISULQWHGRQ$SRUWUDLW [ 0$3/(*(1' 0$3,1)250$7,21 $UHDRI,QWHUHVW $2, $UHDRI,QWHUHVW $2, 6RLOV 6RLO5DWLQJ3RO\JRQV               1RWUDWHGRUQRWDYDLODEOH 6RLO5DWLQJ/LQHV               1RWUDWHGRUQRWDYDLODEOH 6RLO5DWLQJ3RLQWV               1RWUDWHGRUQRWDYDLODEOH :DWHU)HDWXUHV 6WUHDPVDQG&DQDOV 7UDQVSRUWDWLRQ 5DLOV ,QWHUVWDWH+LJKZD\V 865RXWHV 0DMRU5RDGV /RFDO5RDGV 7DEOH².)DFWRU:KROH6RLO .)DFWRU .)DFWRU:KROH6RLO²6XPPDU\E\0DS8QLW²/DULPHU&RXQW\$UHD&RORUDGR &2 0DSXQLWV\PERO 0DSXQLWQDPH 5DWLQJ $FUHVLQ$2, 3HUFHQWRI$2,  /RYHODQGFOD\ORDPWR SHUFHQWVORSHV     7DEOH0RXQWDLQORDP WRSHUFHQWVORSHV    7RWDOVIRU$UHDRI,QWHUHVW   5DWLQJ2SWLRQV².)DFWRU:KROH6RLO .)DFWRU $JJUHJDWLRQ0HWKRG'RPLQDQW&RQGLWLRQ &RPSRQHQW3HUFHQW&XWRII1RQH6SHFLILHG 7LHEUHDN5XOH+LJKHU /D\HU2SWLRQV +RUL]RQ$JJUHJDWLRQ0HWKRG  &XVWRP6RLO5HVRXUFH5HSRUW 0DS²:LQG(URGLELOLW\*URXS :LQG(URGLELOLW\*URXS                                     ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ  : ƒ  1 ƒ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²:LQG(URGLELOLW\*URXS :LQG(URGLELOLW\*URXS :LQG(URGLELOLW\*URXS²6XPPDU\E\0DS8QLW²/DULPHU&RXQW\$UHD&RORUDGR &2 0DSXQLWV\PERO 0DSXQLWQDPH 5DWLQJ $FUHVLQ$2, 3HUFHQWRI$2,  /RYHODQGFOD\ORDPWR SHUFHQWVORSHV     7DEOH0RXQWDLQORDP WRSHUFHQWVORSHV    7RWDOVIRU$UHDRI,QWHUHVW   5DWLQJ2SWLRQV²:LQG(URGLELOLW\*URXS :LQG(URGLELOLW\*URXS $JJUHJDWLRQ0HWKRG'RPLQDQW&RQGLWLRQ &RPSRQHQW3HUFHQW&XWRII1RQH6SHFLILHG 7LHEUHDN5XOH/RZHU &XVWRP6RLO5HVRXUFH5HSRUW  5HIHUHQFHV $PHULFDQ$VVRFLDWLRQRI6WDWH+LJKZD\DQG7UDQVSRUWDWLRQ2IILFLDOV $$6+72 8QLWHG6WDWHV'HSDUWPHQWRI$JULFXOWXUH1DWXUDO5HVRXUFHV&RQVHUYDWLRQ6HUYLFH 1DWLRQDOVRLOVXUYH\KDQGERRNWLWOH9,KWWSZZZQUFVXVGDJRYZSVSRUWDO QUFVGHWDLOVRLOVVFLHQWLVWV"FLG QUFVSB 8QLWHG6WDWHV'HSDUWPHQWRI$JULFXOWXUH1DWXUDO5HVRXUFHV&RQVHUYDWLRQ6HUYLFH /DQGUHVRXUFHUHJLRQVDQGPDMRUODQGUHVRXUFHDUHDVRIWKH8QLWHG6WDWHV WKH&DULEEHDQDQGWKH3DFLILF%DVLQ86'HSDUWPHQWRI$JULFXOWXUH+DQGERRN KWWSZZZQUFVXVGDJRYZSVSRUWDOQUFVGHWDLOQDWLRQDOVRLOV" FLG QUFVSB 8QLWHG6WDWHV'HSDUWPHQWRI$JULFXOWXUH6RLO&RQVHUYDWLRQ6HUYLFH/DQG FDSDELOLW\FODVVLILFDWLRQ86'HSDUWPHQWRI$JULFXOWXUH+DQGERRNKWWS ZZZQUFVXVGDJRY,QWHUQHW)6(B'2&80(176QUFVSBSGI &XVWRP6RLO5HVRXUFH5HSRUW  4,514 752.3 FCMaps This map is a user generated static output from the City of Fort Collins FCMaps Internet mapping site and is for reference only. Data layers that appear on this map may or may not be accurate, current, or otherwise reliable. City of Fort Collins - GIS 572.0 1: WGS_1984_Web_Mercator_Auxiliary_Sphere 0 286.00 572.0 Feet Notes Legend 3,430 FEMA Floodplain FEMA High Risk - Floodway FEMA High Risk - 100 Year FEMA Moderate Risk - 100 / 500 Year FEMA Map Panel City Floodplains City High Risk - Floodway City High Risk - 100 Year City Moderate Risk - 100 Year City Limits Project Site RAINFALL INTENSITY-DURATION-FREQUENCY CURVE 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 0.00 10.00 20.00 30.00 40.00 50.00 60.00 STORM DURATION (minutes) RAINFALL INTENSITY (inches/hour) 2-Year Storm 10-Year Storm 100-Year Storm Figure RA-16 City of Fort Collins Rainfall Intensity-Duration-Frequency Curves Runoff Chapter 6 6-8 Urban Drainage and Flood Control District January 2016 Urban Storm Drainage Criteria Manual Volume 1 Table 6-3. Recommended percentage imperviousness values Land Use or Percentage Imperviousness Surface Characteristics (%) Business: Downtown Areas 95 Suburban Areas 75 Residential: Single-family 2.5 acres or larger 12 0.75 – 2.5 acres 20 0.25 – 0.75 acres 30 0.25 acres or less 45 Apartments 75 Industrial: Light areas 80 Heavy areas 90 Parks, cemeteries 10 Playgrounds 25 Schools 55 Railroad yard areas 50 Undeveloped Areas: Historic flow analysis 2 Greenbelts, agricultural 2 Off-site flow analysis (when land use not defined) 45 Streets: Paved 100 Gravel (packed) 40 Drive and walks 90 Roofs 90 Lawns, sandy soil 2 Lawns, clayey soil 2 0.22 BASIN B 0.61 0.76 0.15 BASIN A4 0.95 1.19 0.13 BASIN A1 0.95 1.19 0.20 BASIN A2 0.95 1.19 0.12 BASIN A3 0.95 1.19 0.07 BASIN A5 0.95 1.19 0.14 BASIN A6 0.95 1.19 1.38 BASIN A 0.87 1.08 0.41 BASIN C 0.15 0.19 0.60 BASIN D 0.18 0.22 0.88 3.94 0.92 1.24 4.18 5.63 4.82 19.34 LEGEND EXISTING PROPOSED PROPERTY LINE FLOWLINE BACK OF CURB EASEMENT SETBACK LINE MAJOR CONTOURS MINOR CONTOURS STORM SEWER SPOT ELEVATION FLOW ARROW FINISH FLOOR ELEVATION HIGH POINT LOW POINT GRADE BREAK FFE HP LP ROADWAY CENTERLINE SIDEWALK SW FLOWLINE FL STORM MANHOLE GRATE INLET WATER LINE SANITARY SEWER MATCH EXISTING GRADE MEG BOTTOM OF WALL BOW TOP OF POND TOP BENCHMARK BASIS OF BEARING BASIN PARAMETERS REVISIONS NO. REV. DATE REVISIONS DESCRIPTION project no.: approved by: checked by: drawn by: drawing no.: QA/QC by: date: SHEET TEL 970.461.7733 www.olssonassociates.com 5285 McWhinney Boulevard, Suite 160 Loveland, CO 80538 OLSSON ASSOCIATES ASSUMES NO RESPONSIBILITY FOR EXISTING UTILITY LOCATIONS (HORIZONTAL OR VERTICAL). THE EXISTING UTILITIES SHOWN ON THIS DRAWING HAVE BEEN PLOTTED FROM THE BEST AVAILABLE INFORMATION. IT IS HOWEVER THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES. NOTE THIS DOCUMENT HAS BEEN RELEASED BY OLSSON ASSOCIATES ONLY FOR REVIEW BY REGULATORY AGENCIES AND OTHER PROFESSIONALS, AND IS SUBJECT TO CHANGE. THIS DOCUMENT IS NOT TO BE USED FOR CONSTRUCTION. CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES DRAINAGE BASIN MAP R FORT COLLINS, CO 2017 09-15-2017 017-0150 SPIRIT AT THE RIVER HOTEL MM C_DRN_70150.dwg MM CH C7 PRELIMINARY DESIGN PLANS CH NOTES F G  6WDQGDUGVSHFLILFDWLRQVIRUWUDQVSRUWDWLRQPDWHULDOVDQGPHWKRGVRIVDPSOLQJ DQGWHVWLQJWKHGLWLRQ $PHULFDQ6RFLHW\IRU7HVWLQJDQG0DWHULDOV $670 6WDQGDUGFODVVLILFDWLRQRI VRLOVIRUHQJLQHHULQJSXUSRVHV$6706WDQGDUG' &RZDUGLQ/09&DUWHU)&*ROHWDQG(7/D5RH&ODVVLILFDWLRQRI ZHWODQGVDQGGHHSZDWHUKDELWDWVRIWKH8QLWHG6WDWHV86)LVKDQG:LOGOLIH 6HUYLFH):62%6 )HGHUDO5HJLVWHU-XO\&KDQJHVLQK\GULFVRLOVRIWKH8QLWHG6WDWHV )HGHUDO5HJLVWHU6HSWHPEHU+\GULFVRLOVRIWKH8QLWHG6WDWHV +XUW*:DQG/09DVLODVHGLWRUV9HUVLRQ)LHOGLQGLFDWRUVRIK\GULF VRLOVLQWKH8QLWHG6WDWHV 1DWLRQDO5HVHDUFK&RXQFLO:HWODQGV&KDUDFWHULVWLFVDQGERXQGDULHV 6RLO6XUYH\'LYLVLRQ6WDII6RLOVXUYH\PDQXDO6RLO&RQVHUYDWLRQ6HUYLFH 86'HSDUWPHQWRI$JULFXOWXUH+DQGERRNKWWSZZZQUFVXVGDJRYZSVSRUWDO QUFVGHWDLOQDWLRQDOVRLOV"FLG QUFVSB 6RLO6XUYH\6WDII6RLOWD[RQRP\$EDVLFV\VWHPRIVRLOFODVVLILFDWLRQIRU PDNLQJDQGLQWHUSUHWLQJVRLOVXUYH\VQGHGLWLRQ1DWXUDO5HVRXUFHV&RQVHUYDWLRQ 6HUYLFH86'HSDUWPHQWRI$JULFXOWXUH+DQGERRNKWWS ZZZQUFVXVGDJRYZSVSRUWDOQUFVGHWDLOQDWLRQDOVRLOV"FLG QUFVSB 6RLO6XUYH\6WDII.H\VWRVRLOWD[RQRP\WKHGLWLRQ86'HSDUWPHQWRI $JULFXOWXUH1DWXUDO5HVRXUFHV&RQVHUYDWLRQ6HUYLFHKWWS ZZZQUFVXVGDJRYZSVSRUWDOQUFVGHWDLOQDWLRQDOVRLOV"FLG QUFVSB 7LQHU5:-U:HWODQGVRI'HODZDUH86)LVKDQG:LOGOLIH6HUYLFHDQG 'HODZDUH'HSDUWPHQWRI1DWXUDO5HVRXUFHVDQG(QYLURQPHQWDO&RQWURO:HWODQGV 6HFWLRQ 8QLWHG6WDWHV$UP\&RUSVRI(QJLQHHUV(QYLURQPHQWDO/DERUDWRU\&RUSVRI (QJLQHHUVZHWODQGVGHOLQHDWLRQPDQXDO:DWHUZD\V([SHULPHQW6WDWLRQ7HFKQLFDO 5HSRUW< 8QLWHG6WDWHV'HSDUWPHQWRI$JULFXOWXUH1DWXUDO5HVRXUFHV&RQVHUYDWLRQ6HUYLFH 1DWLRQDOIRUHVWU\PDQXDOKWWSZZZQUFVXVGDJRYZSVSRUWDOQUFVGHWDLOVRLOV KRPH"FLG QUFVSB 8QLWHG6WDWHV'HSDUWPHQWRI$JULFXOWXUH1DWXUDO5HVRXUFHV&RQVHUYDWLRQ6HUYLFH 1DWLRQDOUDQJHDQGSDVWXUHKDQGERRNKWWSZZZQUFVXVGDJRYZSVSRUWDOQUFV GHWDLOQDWLRQDOODQGXVHUDQJHSDVWXUH"FLG VWHOSUGE  0DSVIURPWKH:HE6RLO6XUYH\DUHEDVHGRQWKH:HE0HUFDWRU SURMHFWLRQZKLFKSUHVHUYHVGLUHFWLRQDQGVKDSHEXWGLVWRUWV GLVWDQFHDQGDUHD$SURMHFWLRQWKDWSUHVHUYHVDUHDVXFKDVWKH $OEHUVHTXDODUHDFRQLFSURMHFWLRQVKRXOGEHXVHGLIPRUH DFFXUDWHFDOFXODWLRQVRIGLVWDQFHRUDUHDDUHUHTXLUHG 7KLVSURGXFWLVJHQHUDWHGIURPWKH86'$15&6FHUWLILHGGDWDDV RIWKHYHUVLRQGDWH V OLVWHGEHORZ 6RLO6XUYH\$UHD /DULPHU&RXQW\$UHD&RORUDGR 6XUYH\$UHD'DWD 9HUVLRQ6HS 6RLOPDSXQLWVDUHODEHOHG DVVSDFHDOORZV IRUPDSVFDOHV RUODUJHU 'DWH V DHULDOLPDJHVZHUHSKRWRJUDSKHG $SU²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²$SU  7KHRUWKRSKRWRRURWKHUEDVHPDSRQZKLFKWKHVRLOOLQHVZHUH FRPSLOHGDQGGLJLWL]HGSUREDEO\GLIIHUVIURPWKHEDFNJURXQG LPDJHU\GLVSOD\HGRQWKHVHPDSV$VDUHVXOWVRPHPLQRU VKLIWLQJRIPDSXQLWERXQGDULHVPD\EHHYLGHQW &XVWRP6RLO5HVRXUFH5HSRUW  VKHHW 6RLO0DSPD\QRWEHYDOLGDWWKLVVFDOH DQGWKH5HYLVHG8QLYHUVDO6RLO/RVV(TXDWLRQ 586/( WRSUHGLFWWKH DYHUDJHDQQXDOUDWHRIVRLOORVVE\VKHHWDQGULOOHURVLRQLQWRQVSHUDFUHSHU\HDU 7KHHVWLPDWHVDUHEDVHGSULPDULO\RQSHUFHQWDJHRIVLOWVDQGDQGRUJDQLFPDWWHU DQGRQVRLOVWUXFWXUHDQGVDWXUDWHGK\GUDXOLFFRQGXFWLYLW\ .VDW 9DOXHVRI.UDQJH IURPWR2WKHUIDFWRUVEHLQJHTXDOWKHKLJKHUWKHYDOXHWKHPRUH VXVFHSWLEOHWKHVRLOLVWRVKHHWDQGULOOHURVLRQE\ZDWHU (URVLRQIDFWRU.Z ZKROHVRLO LQGLFDWHVWKHHURGLELOLW\RIWKHZKROHVRLO7KH HVWLPDWHVDUHPRGLILHGE\WKHSUHVHQFHRIURFNIUDJPHQWV    /DQGFDSDELOLW\FODVVLILFDWLRQ QRQLUULJDWHG  F +\GURORJLF6RLO*URXS % (FRORJLFDOVLWH 2YHUIORZ 5;<&2 +\GULFVRLOUDWLQJ 1R 0LQRU&RPSRQHQWV &DUXVR 3HUFHQWRIPDSXQLW SHUFHQW +\GULFVRLOUDWLQJ 1R 3DROL 3HUFHQWRIPDSXQLW SHUFHQW +\GULFVRLOUDWLQJ 1R )OXYDTXHQWLFKDSOXVWROOV 3HUFHQWRIPDSXQLW SHUFHQW /DQGIRUP 7HUUDFHV +\GULFVRLOUDWLQJ <HV &XVWRP6RLO5HVRXUFH5HSRUW   7UHDG 'RZQVORSHVKDSH /LQHDU $FURVVVORSHVKDSH /LQHDU 3DUHQWPDWHULDO $OOXYLXP 7\SLFDOSURILOH +WRLQFKHV ORDP +WRLQFKHV ORDPFOD\ORDPVLOWORDP +WRLQFKHV +WRLQFKHV 3URSHUWLHVDQGTXDOLWLHV 6ORSH WRSHUFHQW 'HSWKWRUHVWULFWLYHIHDWXUH 0RUHWKDQLQFKHV 1DWXUDOGUDLQDJHFODVV :HOOGUDLQHG 5XQRIIFODVV /RZ &DSDFLW\RIWKHPRVWOLPLWLQJOD\HUWRWUDQVPLWZDWHU .VDW  0RGHUDWHO\KLJKWR KLJK WRLQKU 'HSWKWRZDWHUWDEOH 0RUHWKDQLQFKHV )UHTXHQF\RIIORRGLQJ 1RQH &XVWRP6RLO5HVRXUFH5HSRUW   7UHDG 'RZQVORSHVKDSH /LQHDU $FURVVVORSHVKDSH /LQHDU 3DUHQWPDWHULDO $OOXYLXP 7\SLFDOSURILOH +WRLQFKHV FOD\ORDP +WRLQFKHV FOD\ORDPVLOW\FOD\ORDPORDP +WRLQFKHV YHU\JUDYHOO\VDQGJUDYHOO\VDQGJUDYHOO\FRDUVHVDQG +WRLQFKHV +WRLQFKHV +WRLQFKHV +WRLQFKHV 3URSHUWLHVDQGTXDOLWLHV 6ORSH WRSHUFHQW 'HSWKWRUHVWULFWLYHIHDWXUH 0RUHWKDQLQFKHV 1DWXUDOGUDLQDJHFODVV 3RRUO\GUDLQHG 5XQRIIFODVV 0HGLXP &DSDFLW\RIWKHPRVWOLPLWLQJOD\HUWRWUDQVPLWZDWHU .VDW  0RGHUDWHO\KLJK  WRLQKU 'HSWKWRZDWHUWDEOH $ERXWWRLQFKHV )UHTXHQF\RIIORRGLQJ 2FFDVLRQDO )UHTXHQF\RISRQGLQJ 1RQH &DOFLXPFDUERQDWHPD[LPXPLQSURILOH SHUFHQW 6DOLQLW\PD[LPXPLQSURILOH 9HU\VOLJKWO\VDOLQHWRVOLJKWO\VDOLQH WR PPKRVFP $YDLODEOHZDWHUVWRUDJHLQSURILOH 9HU\KLJK DERXWLQFKHV ,QWHUSUHWLYHJURXSV /DQGFDSDELOLW\FODVVLILFDWLRQ LUULJDWHG  Z /DQGFDSDELOLW\FODVVLILFDWLRQ QRQLUULJDWHG  Z +\GURORJLF6RLO*URXS & +\GULFVRLOUDWLQJ 1R &XVWRP6RLO5HVRXUFH5HSRUW  DFFXUDWHFDOFXODWLRQVRIGLVWDQFHRUDUHDDUHUHTXLUHG 7KLVSURGXFWLVJHQHUDWHGIURPWKH86'$15&6FHUWLILHGGDWDDV RIWKHYHUVLRQGDWH V OLVWHGEHORZ 6RLO6XUYH\$UHD /DULPHU&RXQW\$UHD&RORUDGR 6XUYH\$UHD'DWD 9HUVLRQ6HS 6RLOPDSXQLWVDUHODEHOHG DVVSDFHDOORZV IRUPDSVFDOHV RUODUJHU 'DWH V DHULDOLPDJHVZHUHSKRWRJUDSKHG $SU²$SU  7KHRUWKRSKRWRRURWKHUEDVHPDSRQZKLFKWKHVRLOOLQHVZHUH FRPSLOHGDQGGLJLWL]HGSUREDEO\GLIIHUVIURPWKHEDFNJURXQG LPDJHU\GLVSOD\HGRQWKHVHPDSV$VDUHVXOWVRPHPLQRU VKLIWLQJRIPDSXQLWERXQGDULHVPD\EHHYLGHQW &XVWRP6RLO5HVRXUFH5HSRUW  VKHHW 6RLO0DSPD\QRWEHYDOLGDWWKLVVFDOH L1 S1 Ti L2 V T2 (ft) (%) (min) (ft) (f/s) (min) A 40.0 3.70% 0.71 2.95 393.0 2.2 3.0 5.94 15.12 5.94 B 60.0 4.00% 0.45 5.84 - 5.84 17.35 5.84 C 100.0 2.00% 0.05 15.24 - 15.24 26.93 15.24 A1 - 0.00% 0.77 - 20.0 1.6 0.2 0.21 10.89 5.00 A2 - 0.00% 0.77 - 20.0 1.6 0.2 0.21 10.89 5.00 A3 - 0.00% 0.77 - 20.0 1.6 0.2 0.21 10.89 5.00 A4 - 0.00% 0.77 - 25.0 1.6 0.3 0.26 10.94 5.00 A5 - 0.00% 0.77 - 25.0 1.6 0.3 0.26 10.94 5.00 A6 - 0.00% 0.77 - 20.0 1.6 0.2 0.21 10.89 5.00 D 177.0 1.96% 0.08 19.93 107.0 3.7 0.5 20.41 28.28 20.41 1 600.0 0.10% 0.10 96.19 - 96.19 55.67 55.67 BASIN C5 Check Tc Eq 6-5 Total Tc (min) Final Tc (min) OVERLAND FLOW GUTTER FLOW 1 STORM DRAINAGE CALCULATION Storm Duration 60 minutes C10 A Parking 1.38 0.71 0.74 0.82 5.9 0.00 4.66 9.53 - 4.75 10.78 B Undetained North 0.22 0.45 0.48 0.67 5.8 0.00 4.69 9.58 - 0.50 1.41 C Undetained South 0.41 0.05 0.15 0.49 15.2 0.00 3.17 6.49 - 0.19 1.30 A1 Roof 0.13 0.77 0.80 0.85 5.0 0.00 4.87 9.95 - 0.51 1.12 A2 Roof 0.20 0.77 0.80 0.85 5.0 0.00 4.87 9.95 - 0.77 1.69 A3 Roof 0.12 0.77 0.80 0.85 5.0 0.00 4.87 9.95 - 0.47 1.03 A4 Roof 0.15 0.77 0.80 0.85 5.0 0.00 4.87 9.95 - 0.57 1.25 A5 Roof 0.07 0.77 0.80 0.85 5.0 0.00 4.87 9.95 - 0.26 0.57 A6 Roof 0.14 0.77 0.80 0.85 5.0 0.00 4.87 9.95 - 0.53 1.16 D Detention Pond & Rain 0.60 Garden 0.08 0.17 0.50 20.4 0.00 2.83 5.80 - 0.29 1.74 Q 5- Q Q 5 yr 10 yr 100 yr (cfs) (cfs) (cfs) 1 0.00 3.41 0.10 0.19 0.52 55.7 0.00 1.52 3.10 - 0.53 5.47 C5 C100 Basin Characteristics AREA (acres) Description C5 Basin Characteristics Intensities I 100-yr (cfs) Description C10 C100 Sub-basin AREA (acres) I 10-yr (cfs) I 5-yr (cfs) Q 10-yr (cfs) I 10-yr (cfs) I 5-yr (cfs) * If time of concentration was less than 5 minutes, 5 minutes was used. BASIN NAME I 100-yr (cfs) * If time of concentration was less than 5 minutes, 5 minutes was used. Intensities Sub-basin BASIN NAME Tc* (min) Q 100-yr (cfs) Q 5- yr (cfs) Tc* (min)