HomeMy WebLinkAboutPEDERSEN TOYOTA EXPANSION - FDP - FDP180007 - CORRESPONDENCE - RESPONSE TO STAFF REVIEW COMMENTSBHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 1 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com City of Fort Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 Department: Engineering Development Review Contact: Morgan Uhlman, 970-416-4344, muhlman@fcgov.com Topic: General Comment Number: 1 Comment Originated: 03/20/2018 03/20/2018: 03/19/2018: From Tyler Siegmund's files, the utility providers were fine with a reduced UE along College, 9' minimum. Please dedicate a 9' utility easement along the College Ave frontage. 08/19/2014: Per current road standards for an arterial roadway, a 15ft utility easement should be provided along the College Ave frontage of the property. If this utility easement is not needed by utility providers the 15ft UE requirement may be reduced in size or waived. Coordination with utility providers (COFC Water, COFC Light and Power, COFC Storm water, Comcast, Century Link, Public Service Company of Colorado) is needed to determine if this easement is needed." Response: A 9’ utility easement is now shown along College Ave. Comment Number: 3 Comment Originated: 03/20/2018 03/20/2018: "Add the following note to the site plan: Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. " • Acknowledged and added to Site Plan as ‘Note 9’ Comment Number: 4 Comment Originated: 03/20/2018 03/20/2018: The 15' utility easement behind College Ave was not needed, but the utility providers want a standard 9' utility easement. Please show that on all final BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 2 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com plan documents. Response: A 9’ utility easement is now shown along College Ave. Comment Number: 5 Comment Originated: 03/20/2018 03/20/2018: Please add cross slope and running slope labels and spot elevations for curb ramps to show they are ADA compliant. Response: Slopes are now shown on the grading plan and are all within ADA requirements. Comment Number: 6 Comment Originated: 03/20/2018 For the sidewalk widening along College Ave and Mason Street, there is some work being proposed outside of the properties frontage for a transition. Is that all in the right-of-way or is it on the adjacent property? If it is on the adjacent property, a temporary construction easement will be needed between the two owners before construction can begin. Response: The sidewalk along Mason has been adjusted to maintain improvements within ROW Comment Number: 7 Comment Originated: 03/20/2018 The next steps will include drafting and finalizing the Development Agreement and issuing a Development Construction Permit (DCP). The draft Agreement will be assembled after comments have been resolved by the other departments, I have received their language for the Development Agreement, and the Information for Development Agreement sheet is returned to me from the owner/developer. For more information on the DCP, please go to this website: https://www.fcgov.com/engineering/devrev.php Response: The Development Agreement application has been submitted. Comment Number: 8 Comment Originated: 03/20/2018 03/20/2018: Please see redlines for minor comments. Response: The redlines have been addressed. Topic: Site Plan 03/20/2018: Please depict the driveways off of Kensington Drive and Mason Street as concrete in the right-of-way. BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 3 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com Response: Corrected. Department: Environmental Planning Contact: Stephanie Blochowiak, 970-416-4290, sblochowiak@fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 03/20/2018 03/20/2018: Clarify both "Dryland Seed Mix" and "Wetland Seed Mix" called for on plans. Will need: species list including scientific names, percent each species contributes to mix in addition to pounds per acre and/or pounds per square foot application rate for drill seed and broadcast seed. Recommend using a mix containing both cool and warm season native and/or native-adapted species. Minimum 15 lbs/acre drill seed rate and double that for broadcast rate. List and mix options can be provided. • Correction made. Comment Number: 2 Comment Originated: 03/20/2018 03/20/2018: Add ‘NATIVE SEED MIX NOTES’ • Acknowledged and added to Sheet 4 Comment Number: 3 Lighting plan shows all 4000K CCT to be selected - please update to warmer color temperatures (warm white). The American Medical Association (AMA) and International Dark-Sky Association (IDA) both recommend using lighting that has a corrected color temperature (CCT) of no more than 3000 degrees Kelvin in order to limit the amount of blue light in the night environment. Cooler color temperatures are harsher at night and cause more disruption to circadian (biological) rhythms for both humans and wildlife and blue light brightens the night sky and creates more glare than any other color of light. Both LED and metal halide fixtures contain large amounts of blue light in their spectrum, and exposure to blue light at night has been shown to harm human health and endanger wildlife. Therefore, use of warmer color temperature (warm white, 3000K or less) for light fixtures is preferred in addition to fixtures with motion-sensing or dimming capabilities. Site light sources shall be fully shielded and down-directional to minimize up-light, light spillage and glare [see LUC 3.2.4(D)(3)]. Selecting 3000K or less luminaires supports City of Fort Collins Night Sky Objectives. For further information regarding health effects please see: http://darksky.org/ama-report- affirms-human-health-impacts-from-leds/ AW Comment Response: Understanding the city’s request for the warmer light levels, it is a Toyota corporate standard for vehicle display to have a 4000K CCT fixture temperature, if light levels are lowered to 3000K or less then the vehicle paint colors are altered. However, the site photometric design has taken a conscious approach to the overall site lighting and BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 4 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com we have limited the number of fixtures to what will be considered a minimum for the Toyota corporate standards. Furthermore, the site lighting has been designed not to bleed off the property. Department: Forestry Contact: Molly Roche, , mroche@fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 03/20/2018 Continued: Please address the status of this previous comment. I was not working for the City of Fort Collins Forestry Division at this time and Tim Buchanan has since retired, so I cannot ask him about the history of this specific question. 6/25/2014: Thank you for arranging the first tree evaluation meeting. Please set up a second onsite meeting with the City Forester to complete the tree inventory and mitigation plan. As part of that meeting, some further review of the north-most Ash on Mason can occur to consider desirability of removal or retention. Initial discussion at the first meeting indicated the tree would be removed but some further discussion could be beneficial in making a final determination. A second meeting was held onsite with Molly Roche and further evaluation conducted. This resulted in the removal of additional potential hazard trees and the Green Ash along Mason mentioned from the 6/25/2014 comment. Tree mitigation plan has been updated to reflect these changes. Comment Number: 2 Comment Originated: 03/21/2018 3/20/2018: Continued: Please provide tree species diversity in the plant list and list percentages. 6/25/2014: Provide tree species diversity on the final landscape plan and list percentages in the plant list. Identify species on final landscape plan. Tree species diversity added to the plant list Comment Number: 5 Comment Originated: 03/21/2018 3/20/2018: Continued: 8/19/2014: Previous comment number two provided on 6/25/2014 is continued and still active. Tree species diversity added to the plant list Comment Number: 7 Comment Originated: 03/21/2018 Continued: Thank you for providing 33 mitigation trees to meet the requirement. Please upsize mitigation trees as follows: • Canopy shade trees: 3.0” caliper balled and burlapped • Ornamental trees: 2.5” caliper balled and burlapped BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 5 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com • Evergreen trees: 8’ height balled and burlapped In addition, please indicate mitigation trees with an “M” next to the trees on the landscape plans. 8/19/2014:For final landscape plan, include 22 upsized mitigation trees. Mitigation trees should be upsized as follows: • Canopy shade trees: 3.0 inch caliper • Ornamental trees: 2.5 inch caliper • Evergreen trees: 8 feet height Acknowledged – Mitigation trees upsized and (M)’s added to Landscape Plan labels. We are showing 33 upsized trees. Comment Number: 8 Comment Originated: 03/21/2018 3/20/2018: Lindens do not typically survive or thrive in parking lot islands and medians. Please use another species in places where Lindens are shown in the parking lot, such as Kentucky Coffeetree or Catalpa All but one Linden has been removed from islands, most replaced with New Horizon Elm or Texas Red Oak. Comment Number: 9 Comment Originated: 03/21/2018 3/20/2018: Please use the most current City of Fort Collins General Landscape Notes, Tree Protection Notes, and Street Tree notes on the plans, and show the street tree permit note on all landscape sheets to emphasize importance. These notes are available from Molly Roche in City Forestry (mroche@fcgov.com). Acknowledged Notes added to Sheet 4 with reference to notes on Landscape plan. Street tree permit note added to all sheets. Comment Number: 10 Comment Originated: 03/21/2018 3/20/2018: Show location of any stop signs and street lights. Identify these fixtures with a Distinct symbol. Space trees if needed as follows. Stop Signs: 20 feet from sign Street Light: 40 feet for canopy shade trees and 15 feet for ornamental trees Acknowledged Comment Number: 11 Comment Originated: 03/21/2018 3/21/2018: Please confirm that all tree-utility separations meet code. There is (1) TICO on Mason that is less than 5 feet from a sanitary sewer line. In addition, Wes Lamarque commented in the staff meeting on 3/21/18 that some proposed trees along the north boundary need to be shifted or removed because they are encroaching the sanitary sewer line. Please consider adjusting these trees further from the line or BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 6 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com finding another place on the landscape plan to incorporate these trees/shrubs. During our field visit to inventory additional trees along the north boundary line, we should take a look at the existing tree Wes would like removed for the same reason. • Removed the TI CO identified above adjusted street tree spacing along Mason. • Trees encroaching the SS line along the northern property have been removed. Department: Internal Services Contact: Jonathon Nagel, jnagel@fcgov.com Topic: General Comment Originated: 03/16/2018 Comment Number: 1 The Community Recycling Ordinance (No. 109 2016) requires that all business and multifamily complexes subscribe to recycling service by the end of 2020 that is at minimum 1/3 of their overall service capacity (total bin capacity x number of weekly pickups, include both trash and recycling when calculating overall service capacity). In general recycling containers must be at least 50% the size of proposed trash containers to meet this requirement. Please make sure proposed containers meet this requirement and that adequate space is provided in all enclosures. AW Comment Response: Noted. The proposed 6 cubic yard dumpsters (2 trash / 1 recycle) should meet this requirement. Comment Number: 2 I see a plan enlargement for a proposed trash/recycling enclosure on A4.3, but it doesn't appear to match either enclosure on the site plan. Will both enclosures be identical? Please provide updated elevations and plan enlargements for all proposed trash/recycling enclosure and include the overall dimensions, widths of service gates and required pedestrian entrance along with proposed containers and their capacities on them. AW Comment Response: Please see revised sheet A4.3 for the revised trash enclosure and the enclosures at the parking garage (new / used oil enclosures). The trash enclosure has a pedestrian service entrance and (3) 6 cubic yard trash / recycling containers. The oil enclosures are not meant to be pedestrian accessible. The oil containers are serviced from the top only by pump trucks for environmental safety and to eliminate any potential of spillage. Comment Number: 3 The enclosure located behind the existing structure is not conducive to efficient pickup. Being locating at the end of a dead end the collection truck will need to back into or out of the isle increasing the risk of injury and property damage. BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 7 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com AW Comment Response: We have revised the trash enclosure location to aid in efficient pick up, see the updated site plan and enlarged enclosure plan. Comment Number: 4 03/16/2018: Curb cuts will need to be provided in front of all trash/recycling enclosures to allow containers to be wheeled in and out if not done so already. Response: Curb cuts have been added at the new trash enclosure location. Comment Number: 5 The enclosure behind the parking structure will need a pedestrian entrance that is separate from the main service gates. Consider using a door-less entry which will provide safer and more efficient access. AW Comment Response: The enclosures behind the parking structure are for new and used oil tanks. The enclosures are not meant to be pedestrian accessible for safety, see additional explanation in comment response #1 above. Department: Light And Power Contact: Rob Irish, 970-224-6167, rirish@fcgov.com Topic: General Comment Originated: 03/19/2018 Comment Number: 1 Comment Originated: 03/19/2018 03/19/2018: Light & Power has existing streetlights adjacent to the site along Mason St. that may be in conflict with the proposed entrance off of Mason St. Please field locate and show these facilities on the plans. Response: There is one street light that will need to be relocated. Comment Number: 2 Comment Originated: 03/19/2018 03/19/2018: Please field locate and show the existing primary line from College Ave. to the existing transformer on the plans. This line most likely runs through the proposed LID area and may need to be potholed to determine if this line will be in conflict. Comment Number: 3 Certain building materials and or building design may require more clearance for the proposed transformer location. Please adhere to all clearance requirements in the Electric BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 8 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com Service Standards at the following link. http://www.fcgov.com/utilities/business/builders- and-developers/development-forms-guidelines-regulations AW Comment Response: After discussions with the city it was deemed that a screen wall would not be required at the transformer, it has been removed so clearance will not be an issue. Comment Number: 4 Comment Originated: 03/19/2018 03/19/2018: A commercial service information form (C-1 form) and a one line diagram will need to be submitted to Light & Power Engineering. A link to the C-1 form is below: http://www.fcgov.com/utilities/business/builders-and-developers/development-forms -guidelines-regulations Response: Acknowledged Comment Number: 5 Comment Originated: 03/19/2018 03/19/2018: Electric Capacity Fee, Building Site charges, and any system modification charges necessary will apply to this development. Please contact Light & Power Engineering if you have any questions at 970-221-6700. Please reference our Electric Service Standards, development charges and fee estimator at the following link: http://www.fcgov.com/utilities/business/builders-and-developers Response: Acknowledged Comment Number: 6 What is the dark line shown in front of the proposed transformer location? AW Comment Response: This line was the transformer screen wall, see Comment response #3 above, the screen wall has been removed. Department: PFA Contact: Andrew Rosen, , arosen@fcgov.com Topic: General Comment Number: 1 Comment Originated: 03/20/2018 03/21/2018: UPDATE The final site plan will reflect this change. 03/19/2018: Per the IFC 2015, the Emergency Access Easement is now allowed to be 26ft in width rather than the 30ft shown but it cannot be located closer than 15ft to the edge of the building. BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 9 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com Response: The EAE along the west side of the garage is 15 ft off of the garage and labeled on the Horizontal Control Plan. Comment Number: 2 Comment Originated: 03/20/2018 03/21/2018: UPDATE Project team stated they will provided a Fire Lane signage plan for approval in PDF. 03/19/2018: The signage plan for the Fire Lanes should be available for review by PFA before the FDP can be approved. Response: The fire lane signage is shown on the Horizontal Control Plan. We were limited on the availability of where signage could be placed, so we used a combination of red painted curb and no parking signage. Comment Number: 3 Comment Originated: 03/20/2018 03/21/2018: UPDATE Project team stated they will delete the cars as shown. The inventory will always be in flux so they need access also. 03/20/2018: Cars are shown on the provided documents parked very closely in the new structure. PFA requests information on how the vehicles will be stored to allow for access. Response: We understand the needs for adequate access within the parking structure and this has been discussed with Pederson. As this will become an operational issue, Pedersen will continue to work with PFA once the new facility is in place to coordinate access requirements and appropriate inventory parking to allow for this. Department: Planning Services Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com Comment Number: 1 Comment Originated: 03/20/2018 03/20/2018: On the Plat the signature block for Planning, "Director of" appears twice, delete one. On the signature line edit to CDNS Director. • Acknowledged, “Director of” removed and replaced with ‘CDNS Director’ Comment Number: 2 Comment Originated: 03/20/2018 03/20/2018: Note 8 on the site plan should include all signs, not just monument Signs. • Acknowledged, Changed to read ‘Any sign monument or otherwise’ BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 10 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com Comment Number: 3 Comment Originated: 03/20/2018 03/20/2018: On the site plan, the Handicap spaces on the north side of the building, where is the sidewalk ramp connection for these spaces? Response: A ramp has been added at the HC access aisle Comment Number: 4 Comment Originated: 03/20/2018 03/20/2018: Can there be wheels stops or something else to prevent cars parked in the parallel spaces on the south parking area from encroaching into the accessibility route to the entrance of the building? Response: Wheel stops have been added and labeled on the Site Plan Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 03/12/2018 03/12/2018: Please resubmit an Erosion Control Report as the recently received materials has comments and redlines that needed to be addressed to meet City Criteria. Please resubmit an Erosion Control Plans as the recently received materials have comments and redlines that needed to be addressed to meet City Criteria. Please resubmit an Erosion Control Escrow / Security Calculation as the recently received materials has comments and redlines, that needed to be addressed to meet City Criteria and as a result have changed the Erosion Control Plans and would require a recalculation of the Escrow. If you need clarification concerning the Erosion Control Material Requirements or Comments presented above please contact myself. Jesse Schlam (970) 224-6015 jschlam@fcgov.com Response: The erosion control plan and report have been updated and comments addressed. There was concern about the use of erosion control log around portions of the site exterior. The areas proposed with the erosion logs have very limited sheet flows area and we believe these are adequate in these areas. Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General Comment Number: 1 Comment Originated: 03/19/2018 03/19/2018: Please make changes as marked. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 11 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com provide any responses on redlined sheets and/or in response letter. Response: The updated title commitment was not available in time for this submittal and will be updated once received. Comment Number: 2 Comment Originated: 03/20/2018 03/20/2018: The void ratio the City has for criteria is 30% in the No. 2 rock. Please revise detention calculations. Response: All LID calculations have been updated. Comment Number: 3 Comment Originated: 03/20/2018 03/20/2018: An overflow inlet is required at the low point for all the porous paver areas. This is to prevent standing water in the sump locations for the paver areas. Response: Overflow inlets are provided at the low-points in the pavers. Comment Number: 4 Comment Originated: 03/23/2018 03/23/2018: Please verify the run-on ratios for the porous pavers located in the table. The ratios need to include all the impervious area draining onto the pavers including the roofs of all the buildings. Response: All LID calculations have been updated and includes the roof areas. Comment Number: 5 Comment Originated: 03/23/2018 03/23/2018: Please include an orifice detail for the quantity detention. Response: The orifice plate is now called out in multiple locations. Comment Number: 6 Comment Originated: 03/23/2018 03/23/2018: The porous paver detail needs some edits and the City detail can be used. More discussion is needed . Response: We maintained the non-woven fabric across the bottom of the pond to limit sediment migrating up into the paver section and that would potentially cause settling. Comment Number: 7 Comment Originated: 03/23/2018 03/23/2018: Is enough area draining onto porous paver area 1 to use the volume in the aggregate as quantity detention? BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 12 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com Response: Paver area 1 has been removed and all detention is provided in the pond for this basin Comment Number: 8 Comment Originated: 03/23/2018 03/23/2018: Please label scour stop mats on the grading plans and erosion control plan. Is any riprap being proposed? A detail was provided. Response: Scourstop is called out and details are provided. Department: Technical Services Contact: Jeff County, jcounty@fcgov.com Topic: Site Plan Comment Number: 2 Comment Originated: 03/19/2018 03/19/2018: Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See redlines. • Acknowledged and corrected Comment Number: 3 Comment Originated: 03/19/2018 03/19/2018: Please revise the legal description as marked. See redlines. • Acknowledged and corrected Comment Number: 4 Comment Originated: 03/19/2018 03/19/2018: There is text that needs to be masked. Mask all text in hatched areas. See redlines. • Acknowledged and corrected Comment Number: 5 Comment Originated: 03/19/2018 03/19/2018: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. • Acknowledged and corrected Comment Number: 6 Comment Originated: 03/19/2018 03/19/2018: There are line over text issues. See redlines. • Acknowledged and corrected Comment Number: 7 Comment Originated: 03/19/2018 03/19/2018: There are text over text issues. See redlines. • Acknowledged and corrected Comment Number: 8 BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 13 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com Please change the title as marked on all sheets to "Pedersen Toyota Expansion" to match the other plan sets. See redlines. AW Comment Response: Noted all title sheets have been updated to read Pedersen Toyota Expansion. Comment Number: 9 03/19/2018: There are line over text issues. See redlines. AW Comment Response: Noted please see revised sheets A4.1 and A4.2. Comment Number: 10 Please change the title as marked on all sheets to "Pedersen Toyota Expansion" to match the other plan sets. AW Comment Response: Noted all title sheets have been updated to read Pedersen Toyota Expansion. Comment Number: 11 Comment Originated: 03/19/2018 03/19/2018: Please revise the sub-title as marked. See redlines. • Acknowledged, changed Sub-Title to read ‘Pedersen Toyota Expansion’ Comment Number: 12 Comment Originated: 03/19/2018 03/19/2018: Please provide the following information in the EXACT format shown. PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM) BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + X.XX’. Response: Benchmark description has been updated. Comment Number: 13 Comment Originated: 03/19/2018 03/19/2018: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. • Acknowledged, Easements match the PLAT. Comment Number: 14 BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 14 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com Comment Originated: 03/19/2018 03/19/2018: Please tie the coordinate values shown to the project boundary. We would prefer that this be done by adding property corner values to each sheet, or showing the property corner values on the horizontal control plans and adding a note to each sheet with coordinate values. Response: Property corners northing-eastings are provided on the Horizontal Control Plan Comment Number: 15 Comment Originated: 03/19/2018 03/19/2018: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Response: Line over text issues have been corrected. Comment Number: 16 Comment Originated: 03/20/2018 03/20/2018: Please make sure the right of way & easement descriptions shown match what is shown on the Subdivision Plat. Response: Descriptions have been corrected Department: Traffic Operations Contact: Tim Tuttle Topic: General Comment Number: 1 Comment Originated: 03/19/2018 03/22/2018: The TIS has been accepted per LCUASS 4.8.1. Response: Acknowledged Comment Number: 2 Comment Originated: 03/22/2018 03/22/2018: No comments on the final plan related to signing and striping. Response: Acknowledged Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 03/21/2018 03/21/2018: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Response: Acknowledged. Irrigation plans will be included with the building permit submittals for your review. BHA Design Incorporated 1603 Oakridge Drive Fort Collins, CO 80525 Page 15 of 15 voice: 970.223.7577 fax: 970.223.1827 landscape architecture | planning | urban design www.bhadesign.com Department: Water-Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General Comment Number: 1 Comment Originated: 03/20/2018 03/20/2018: There are proposed tress located along the northern property line within the utility easement. Please remove all the trees within the easement. See redlines. Response: Offsite trees are not proposed to be removed though we are removing some of the trees along the easement within the Pedersen site. Comment Number: 2 Comment Originated: 03/20/2018 03/20/2018: Please show the existing curb stops and meter pits for the existing water services. Response: We believe all existing utilities are now indicated on the plans. Comment Number: 3 Comment Originated: 03/20/2018 03/20/2018: Please label the existing water and sewer lines north of the site. Response: Water and sewer lines are indicated on the plans.