HomeMy WebLinkAboutMASON PLACE - MAJOR AMENDMENT - MJA180003 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLANMASON STREET
CREGER DRIVE
EXISTING
BUILDING
CONCEPTUAL
AMENITY
SPACE
2 - TR
1 - GDI
3 - PGG
1 - GDI
3 - MRA
2 - MRA
5 - CP3
1 - QMA
1 - PCC
QS2 - 4
UMA - 3
PROPPOSED ROW
6' DETACHED SIDEWALK
26'-0"
EMERGENCY
ACCESS
EASEMENT
15' UTILITY EASEMENT
PROPOSED ROW
4'-6" DETACHED SIDEWALK
TRASH AND RECYCLING
ENCLOSURE, SEE ARCH
DECORATIVE FENCE ENDS AT BUIDLING
DECORATIVE FENCE ENDS AT BUIDLING
MAIN ENTRY
(M)
(M)
(M)
(M)
(M)
(M)
3 - PCC
TREES QTY BOTANICAL NAME / COMMON NAME CONT CAL
CP3 5 CELTIS OCCIDENTALIS `PRAIRIE SENTINEL` / PRAIRIE SENTINEL HACKBERRY B & B 2"
GDI 2 GYMNOCLADUS DIOICA `ESPRESSO` / KENTUCKY COFFEETREE B & B 2"
MRA 5 MALUS X `RADIANT` / RADIANT CRAB APPLE B & B 1.5"
PGG 3 PRUNUS SALICINA `GREEN GAGE` / GREEN GAGE PLUM B & B 1.5"
PCC 4 PYRUS CALLERYANA `CHANTICLEER` / CHANTICLEER PEAR B & B 1.5"
QMA 1 QUERCUS MACROCARPA / BURR OAK B & B 2"
QS2 4 QUERCUS SHUMARDII / SHUMARD RED OAK B & B 2"
TR 2 TILIA AMERICANA `REDMOND` / REDMOND AMERICAN LINDEN B & B 2"
UMA 3 ULMUS X `ACCOLADE` / ACCOLADE ELM B & B 2"
SHURB BED - MODERATE HYDROZONE 5,196 SF
IRRIGATED TURF - HIGH HYDROZONE 11,176 SF
CANOPY TREE
ORNAMENTAL TREE
(M M) UPSIZED 1" ABOVE SPECIFIED FOR MITIGATION
EXISTING TREES TO REMAIN
DESIGNATED ADA PARKING STALL
SWALE
WATER LINE
UNDERGROUND ELECTRIC
TELEPHONE LINE
HYDROZONE
AREA (SF) WATER NEEDED
(GALLONS/SF)
ANNUAL WATER USE
(GALLONS)
HIGH
11176.00 18
201,168.00
MODERATE
5196.00 10 51,960.00
LOW 0.00 3 0.00
VERY LOW 0.00
0 0.00
TOTAL 16,372 15.4610 253,128
ANNUAL WATER USE NOT TO EXCEED 15 GAL./SF. AVERAGE OVER THE SITE
PER CITY OF FORT COLLINS 3.2.1(D)3 PROPOSED PLAN MUST HAVE A SPECIES DIVERSITY
OF (10-19 TREES > 50%, 20-39 TREES > 33%, 40-59 TREES > 25%, 60+ TREES > 15%). OF THE
28 TOTAL TREES SURVEYED AND PROPOSED ON SITE, NO SPECIES MAY HAVE MORE THAN
9 QUANTITY.
TREE SPECIES COUNT 60+ TREES > 15%
CELTIS OCCIDENTALIS 5 17
GYMNOCLADUS DIOICA 2 7
MALUS X 'RADIANT' 5 17
PRUNUS SALICINA 'GREEN GAGE' 3 10
PYRUS CALLERYANA
'CHANTICLEER' 4 14
QUERCUS MACROCARPA 1 3
QUERCUS SHUMARDII 4 14
TILIA AMERICANA 'REDMOND' 2 7
ULMUS X ACCOLADE 3 10
TOTAL TREES 29
*CITY OF FORT COLLINS CODE SECTION 3.2.1(D)3 MINIMUM SPECIES
DIVERSITY
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Klara Rossouw Layout: 3 LANDSCAPE NOTES AND DETAILS Printed On: 4/24/2018 3:08 PM File Name: 4 LANDSCAPE PLAN.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
HOUSING CATALYST
1715 W. Mountain Avenue
1
2
3
4
5
7 8
9
10
11
12
13
14
15
16
17
6
19
18
20
21
22
23
24
25
26
27
# TYPE DBH CONDITION MITIGATION NOTES REMOVAL
1 ROCKY MOUNTAIN JUNIPER 8" FAIR 1
2 COLORADO BLUE SPRUCE 13 FAIR + 1.5
3 COLORADO BLUE SPRUCE 12" FAIR + 1.5
4 ASH 12" FAIR + 1.5 YES - ROW
IMPROVEMENTS
5 ASH 12" FAIR + 1 YES - ROW
IMPROVEMENTS
6 CRABAPPLE 12" FAIR + 1 YES - PARKING LOT
REDESIGN
7 ASH 10" FAIR - 1.0 YES - PARKING LOT
REDESIGN
8 ASH 12" FAIR 1.0 YES - PARKING LOT
REDESIGN
9 AUSTRIAN PINE 25" FAIR + 2.5 YES - PARKING LOT
REDESIGN
10 AUSTRIAN PINE 24" FAIR - 2.0
11 AUSTRIAN PINE 24" FAIR + 2.5
12 CRABAPPLE 10" FAIR 1.0 YES - PARKING LOT
REDESIGN
13 CRABAPPLE 10" FAIR 1.0
14 ROCKY MOUNTAIN JUNIPER 10" FAIR 1
15 ROCKY MOUNTAIN JUNIPER 9" FAIR 1
2.0 ROCKY MOUNTAIN JUNIPER 10" FAIR 1
17 CRABAPPLE 14" FAIR + 1.5
18 ROCKY MOUNTAIN JUNIPER 9" FAIR 1.0
19 ROCKY MOUNTAIN JUNIPER 8" FAIR - 1.0 NEST PRESENT
20 ROCKY MOUNTAIN JUNIPER 8" FAIR - 1.0
21 RUSSIAN OLIVE 10" & 10" POOR 0
YES -
OVERWHELMING
HACKBERRY
22 HACKBERRY (2 STEM) 5" & 5" FAIR 0 NEST PRESENT
23 CRABAPPLE (MULTISTEM) 7" FAIR 1.0
YES - SITE
CIRCULATORY
IMPRVEMENTS
24 HONEY LOCUST 8" FAIR + 1.0
REGRADING
AROUND BUIDING,
NEW LAYOUT
25 HONEY LOCUST 8" GOOD 1.5
REGRADING
AROUND BUIDING,
NEW LAYOUT
26 HONEY LOCUST 10" FAIR + 1.0
REGRADING
AROUND BUIDING,
NEW LAYOUT
27 COLORADO BLUE SPRUCE 18" GOOD 2.0 NEW CURB CUT
REQUIRED MITIGATION TREES (EXCLUDES TREES TO REMAIN AND THOSE OFF
SITE)
TYPE COUNT REQUIRED MITIGATION TREES
TREES PRESERVED 14 0
TREES TO BE REMOVED 13 16
TOTAL 27 16
LOCATION COUNT
MITIGATION TREES PROPOSED TO BE PLANTED ON-SITE 16
MITIGATION TREES PROPOSED TO BE PLANTED OFF-SITE 0
PAYMENT IN LIEU (ASSUMES $450 PER TREE) 0
TOTAL 2
SEE LANDSCAPE PLAN FOR UPSIZED TREES
TREE MITIGATION SUMMARY
PROVIDED TREE MITIGATION
EXISTING TREES TO
SAVE IN PLACE
EXISTING TREES TO
BE REMOVED
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Klara Rossouw Layout: 5 TREE MITIGATION PLAN Printed On: 4/24/2018 3:08 PM File Name: 5 TREE MITIGATION PLAN.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
HOUSING CATALYST
1715 W. Mountain Avenue
Fort Collins, CO 80521
p. 970.416.2910
ENGINEER
ARCHITECT
APPLICANT
JVA INC. CONSULTING ENGINEERS
213 Linden Street, Suite 200
Fort Collins, CO 80524
p. 970.225.9099
SHOPWORKS
2882 Wyandot Street.
Denver, CO 80211
p. 303.433.4094
OWNER
TREE MITIGATION
PLAN
MAJOR AMENDMENT
MASON PLACE PSH
1 MAJOR AMENDMENT 4.25.2018
FORT COLLINS, CO
RL
KR
R18-001
5 OF 10
NORTH
0 10 20 40
SCALE: 1"=20'-0"
TREE PROTECTION NOTES
TREE DIAMETER AT BREAST HEIGHT
(INCHES)
AUGER DISTANCE FROM FACE OF
TREE (FEET)
0-2 1
3-4 2
5-9 5
10-14 10
15-19 12
OVER 19 15
1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL
AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE
PLANS FOR REMOVAL.
2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR
FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS
EVALUATED AND APPROVED THE DISTURBANCE.
3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS
FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A
BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE
REQUIRED BY CODE.
4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL
PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A
MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN
SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS
GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL,
DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE.
5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT
THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE
MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY
OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY
PROTECTED TREE OR GROUP OF TREES.
6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY
PROTECTED TREE.
7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM
CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY
EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING
AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE
ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART
AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS
OF SUCH AREAS BEING CLEARED.
8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE
REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY
BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH
OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF
THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS
DESCRIBED IN THE CHART BELOW:
9. NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO
JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST
COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE
PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL
DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND
CONSTRUCTION APPLY.
10. A QUALIFIED ARBORIST SHALL BE HIRED TO PERFORM AN AERIAL AND GROUND
EVALUATION ON ALL TREES THAT ARE IN POOR OR DEAD CONDITION AND SHALL PROVIDE
A WRITTEN REPORT ON THE SUITABILITY OF RETAINING THESE TREES.
TREE MITIGATION SUMMARY
Fort Collins, CO 80521
p. 970.416.2910
ENGINEER
ARCHITECT
APPLICANT
JVA INC. CONSULTING ENGINEERS
213 Linden Street, Suite 200
Fort Collins, CO 80524
p. 970.225.9099
SHOPWORKS
2882 Wyandot Street.
Denver, CO 80211
p. 303.433.4094
OWNER
LANDSCAPE NOTES
AND DETAILS
MAJOR AMENDMENT
MASON PLACE PSH
1 MAJOR AMENDMENT 4.25.2018
FORT COLLINS, CO
RL
KR
R18-001
3 OF 10
STAKING NOTES:
STAKE TREES PER FOLLOWING SCHEDULE, THEN REMOVE AT
END OF FIRST GROWING SEASON AS FOLLOWS:
1 1/2" CALIPER SIZE - MIN. 1 STAKE ON SIDE OF PREVAILING
WIND. (GENERALLY N.W. SIDE)
1 1/2" - 3" CALIPER SIZE - MIN. 2 STAKES - ONE ON N.W. SIDE,
ONE ON S.W. SIDE
3" CALIPER SIZE AND LARGER - 3 STAKES PER DIAGRAM
WIRE OR CABLE SHALL BE MIN. 12 GAUGE, TIGHTEN ONLY
ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK
MOVEMENT. NYLON STRAPS SHALL BE LONG ENOUGH TO
ACCOMMODATE 1 1/2" OF GROWTH AND BUFFER ALL BRANCHES
FROM WIRE GUYING PLAN
PLANT SO THAT TOP OF ROOT BALL
IS 2" HIGHER THAN FINISHED GRADE
GROMMETED NYLON STRAPS
GALVANIZED WIRE TWIST TO TIGHTEN
6' STEEL T-POSTS (SEE SCHEDULE) DRIVEN
(MIN. 24") FIRMLY INTO UNDISTURBED SOIL
OUTSIDE ROOTBALL.
SCARIFY SIDES OF PLANTING HOLE
LEAVING 1:1 SLOPE
BACKFILL WITH BLEND OF EXISTING
SOIL AND A MAXIMUM 20% (BY
VOL.) ORGANIC MATERIAL TAMP
SOIL AROUND ROOT BALL W/ FOOT
PRESSURE SO THAT IT DOESN'T
SHIFT. WATER THOROUGHLY TO
SETTLE AND REMOVE AIR
POCKETS. PRIOR TO MULCHING,
LIGHTLY TAMP SOIL AROUND THE
ROOT BALL IN 6" LIFTS TO BRACE
TREE. DO NOT OVER COMPACT.
WHEN THE PLANTING HOLE HAS
BEEN BACKFILLED, POUR WATER
AROUND THE ROOT BALL TO
SETTLE THE SOIL.
PRUNING NOTES:
DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE
ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND
BROKEN BRANCHES. SOME INTERIOR TWIGS AND
LATERAL BRANCHES MAY BE PRUNED. HOWEVER, DO
NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT
EXTEND TO THE EDGE OF THE CROWN
3 X BALL DIA.
PREVAILING WIND
3" DEEP MULCH RING PLACED A MINIMUM
OF 6' IN DIAMETER. DO NOT PLACE
MULCH IN CONTACT WITH TREE TRUNK
ROUND-TOPPED SOIL BERM 4" HIGH X 8"
WIDE ABOVE ROOT BALL SURFACE
SHALL BE CONSTRUCTED AROUND THE
ROOT BALL. BERM SHALL BEGIN AT
ROOT BALL PERIPHERY. (OMIT IN TURF
AREAS)
CONIFER TREE PLANTING DETAIL - STEEL POSTS
SCALE: NTS
REMOVE ALL WIRE, TWINE BURLAP,
MESH AND CONTAINERS FROM
ENTIRE ROOT BALL AND TRUNK
1 L-PL2-PLA-01
PREVAILING WIND
PLAN VIEW - THREE STAKES
TREE PLANTING DETAIL - STEEL POSTS
SCALE: NTS
ROUND TOPPED SOIL BERM 4"
HIGH X 8" WIDE ABOVE ROOT
BALL SURFACE SHALL BE
CONSTRUCTED AROUND THE
ROOT BALL. BERM SHALL BEGIN
AT ROOT BALL PERIPHERY. (OMIT
IN TURF AREAS)
NOTES:
SET S0 THAT TOP OF ROOT 1-2"
HIGHER THAN FINISHED GRADE
MARK NORTH SIDE OF TREE IN
NURSERY AND ROTATE TREE TO
FACE NORTH AT THE SITE
WHENEVER POSSIBLE
2 STRAND 12 GAUGE GAL. WIRE
(TWIST TO TIGHTEN) &
GROMMETED NYLON STRAPS
STEEL T-POSTS DRIVEN (MIN. 24") FIRMLY INTO
UNDISTURBED SOIL OUTSIDE OF PLANTING
HOLE BEFORE BACKFILLING
STAKE ABOVE FIRST BRANCHES OR AS
NECESSARY FOR FIRM SUPPORT
BACKFILL WITH BLEND OF EXISTING SOIL
AND A MAXIMUM 20% (BY VOL.) ORGANIC
MATERIAL PLACE FIRMLY BUT DON'T TAMP
OR COMPACT AROUND ROOT BALL. WATER
WATER THOROUGHLY TO SETTLE AND
REMOVE AIR POCKETS. PRIOR TO
MULCHING, LIGHTLY TAMP SOIL AROUND
THE ROOT BALL IN 6" LIFTS TO BRACE
TREE. DO NOT OVER COMPACT. WHEN THE
PLANTING HOLE HAS BEEN BACKFILLED,
POUR WATER AROUND THE ROOT BALL TO
SETTLE THE SOIL.
REMOVE ALL WIRE, TWINE BURLAP, MESH
AND CONTAINERS FROM ENTIRE ROOT
BALL AND TRUNK
3" DEEP MULCH RING PLACED A MINIMUM
OF 6' IN DIAMETER. 1" MULCH OVER ROOT
BALL. DO NOT PLACE MULCH IN CONTACT
WITH TREE TRUNK
3 X BALL DIA.
BOTTOM OF ROOT BALL RESTS ON
EXISTING OR RECOMPACTED SOIL
SCARIFY SIDES OF HOLE LEAVING
1:1 SLOPE
2 L-PL2-PLA-12
PRUNING NOTES:
DO NOT HEAVILY PRUNE SHRUB AT PLANTING.
PRUNE ONLY DEAD OR BROKEN BRANCHES. IF
FORM IS COMPROMISED BY PRUNING,
REPLACE SHRUB
PLACEMENT NOTES:
SET SHRUB PLUMB. SPACE PLANTS, AND
PLACE FOR BEST EFFECT
SET TOP OF ROOTBALL 1-2" HIGHER THAN
ADJACENT GRADE
SCARIFY SIDES AND USE 1:1 SLOPE
3" DEEP MULCH RING 3' IN DIA. PLACE ON
GEOTEXTILE WEED BARRIER. 1" OF MULCH ON
TOP OF ROOT BALL
REMOVE CONTAINER (INCLUDING FIBER
CONTAINERS), BASKETS, WIRE, ETC. FROM THE
ROOT BALL. BREAK UP ENCIRCLING ROOTS
WITH SHARP KNIFE OR SPADE. SPLIT BOTTOM
OF ROOT BALL. PLACE ON UNDISTURBED SOIL
TO PREVENT SETTLEMENT. PRIOR TO
MULCHING, LIGHTLY TAMP SOIL AROUND THE
ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO
NOT OVER COMPACT. WHEN THE PLANTING
HOLE HAS BEEN BACKFILLED, POUR WATER
AROUND THE ROOT BALL TO SETTLE THE SOIL.
BACKFILL WITH BLEND OF EXISTING SOIL
AND A MAX. 20% (BY VOL.) ORGANIC
MATERIAL. WATER THOROUGHLY TO
SETTLE AND REMOVE AIR POCKETS
2 X BALL DIA.
4" HIGH WATER SAUCER
SHRUB PLANTING DETAIL
3 SCALE: NTS L-PL2-PLA-14
WATER USE TABLE
TREE SPECIES DIVERSITY
1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY
DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE
SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL
TREES SHALL BE BALL AND BURLAP OR EQUIVALENT.
2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE
AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN
MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES
DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE
IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES,
INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE)
IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE
IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER
REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL.
3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING
CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING
REVEGETATION AND LANDSCAPING.
4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN
ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING
PARKWAYS AND MEDIANS, SHALL BE THOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN
EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL
OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING OR
OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL
AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE
SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN
THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET
FORTH IN SECTION 12-132.
5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO
SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK
ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER
INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF
CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE
MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY
BUILDING IN SUCH PHASE.
6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER
LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE
PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS.
THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND
SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS
IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS,
WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE
REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION.
7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE
PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS.
8. THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES:
40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS
15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS
10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES
6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES.
4 FEET BETWEEN TREES AND GAS LINES
9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF
DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a).
10.PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE
CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE
ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR
EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST
BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR
EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN.
11.THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS
SO THAT THE PROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT
IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE
12.MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION --
AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND
DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF
CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST, SPECIES AND QUANTITIES
ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST
HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION.
13. ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES.
14.IRRIGATED TURF SHALL BE TEXAS BLUEGRASS/KENTUCKY BLUEGRASS HYBRID REVEILLE OR
APPROVED EQUAL.
15.EDGING BETWEEN GRASS AND SHRUB BEDS SHALL BE 18" X 4" ROLLED TOP STEEL SET LEVEL
WITH TOP OF SOD OR APPROVED EQUAL.
16.STRAW / COCONUT SOIL RETENTION BLANKET SHALL BE APPLIED TO ALL SEEDED AREAS ON
SLOPES GREATER THAN 3:1.
GENERAL LANDSCAPE NOTES
GAS LINE
FIBER OPTIC CABLE
STORM DRAIN
SANITARY SEWER LINE
LOOP BIKE RACK (10 SPACES)
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Klara Rossouw Layout: 4 LANDSCAPE PLAN Printed On: 4/24/2018 3:08 PM File Name: 4 LANDSCAPE PLAN.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
HOUSING CATALYST
1715 W. Mountain Avenue
Fort Collins, CO 80521
p. 970.416.2910
ENGINEER
ARCHITECT
APPLICANT
JVA INC. CONSULTING ENGINEERS
213 Linden Street, Suite 200
Fort Collins, CO 80524
p. 970.225.9099
SHOPWORKS
2882 Wyandot Street.
Denver, CO 80211
p. 303.433.4094
OWNER
LANDSCAPE PLAN
MAJOR AMENDMENT
MASON PLACE PSH
1 MAJOR AMENDMENT 4.25.2018
FORT COLLINS, CO
RL
KR
R18-001
4 OF 10
NORTH
0 10 20 40
SCALE: 1"=20'-0"
LEGEND
GROUND COVER
PLANT SCHEDULE
NOTE:
SHRUBS ARE CONCEPTUALLY SHOWN IN AREAS WHERE SCREENING IS REQUIRED. A MORE DETAILED