HomeMy WebLinkAboutVERIZON FTC PARKWOOD TELECOMMUNICATION FACILITY (WTF) - PDP/FDP - FDP180012 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSRF ENGINEER SITE DIRECTIONS PROJECT DESCRIPTION VICINITY MAP PROJECT DATA SHEET INDEX PROPOSED SITE LOCATION GROUND ELEVATION LATITUDE LONGITUDE CONSTRUCTION ENGINEER GENERAL NOTES APPROVALS (RF): DATE: (CONST.): DATE: (RE): DATE: LANDLORD: DATE: 1. THIS WIRELESS TELECOMMUNICATIONS FACILITY WILL MEET THE HEALTH AND SAFETY STANDARDS FOR ELECTROMAGNETIC FIELD EMISSIONS AS ESTABLISHED BY THE FEDERAL COMMUNICATIONS COMMISSION OR ANY SUCCESSOR THEREOF, AND ANY OTHER FEDERAL OR STATE AGENCY. 2. THIS WIRELESS TELECOMMUNICATIONS FACILITY WILL MEET THE REGULATIONS OF THE FEDERAL COMMUNICATIONS COMMISSION REGARDING PHYSICAL AND ELECTROMAGNETIC INTERFERENCE. 3. LIGHTING OR SIGNS WILL BE PROVIDED ONLY AS REQUIRED BY FEDERAL OR STATE AGENCIES. 4. DEVELOPMENT AND CONSTRUCTION OF THIS PROJECT WILL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. 5. EXISTING PARKING IS NOT AFFECTED BY THIS PROJECT. C L E S U L A C L E C O N S U L T I NG , I N C . I NC . P I N PREPARED FOR: CONSULTING FIRM GN-1 FTC PARKWOOD GENERAL NOTES SOIL COMPACTION NOTES FOR SLAB ON GRADE: 1. EXCAVATE AS REQUIRED TO REMOVE VEGETATION & TOPSOIL EXPOSE UNDISTURBED NATURAL SUBGRADE AND PLACE CRUSHED STONE AS REQUIRED. 2a. COMPACTION CERTIFICATION: AN INSPECTION AND WRITTEN CERTIFICATION BY A QUALIFIED GEOTECHNICAL TECHNICIAN OR ENGINEER IS ACCEPTABLE. 2b. AS AN ALTERNATIVE TO ITEM 2a. THE "UNDISTURBED SOIL" BASE SHALL BE COMPACTED WITH "COMPACTION EQUIPMENT", LISTED BELOW, TO AT LEAST 90% MODIFIED PROCTOR MAXIMUM DENSITY PER ASTM D 1557 METHOD C. 2c. AS AN ALTERNATIVE TO ITEMS 2a AND 2b PROOFROLL THE SUBGRADE SOILS WITH 5 PASSES OF A MEDIUM SIZED VIBRATORY PLATE COMPACTOR [SUCH AS BOMAG BPR 30/38] OR HAND-OPERATED SINGLE DRUM VIBRATORY ROLLER [SUCH AS BOMAG BW 55E]. ANY SOFT AREAS THAT ARE ENCOUNTERED SHOULD BE REMOVED AND REPLACED WITH A WELL-GRADED GRANULAR FILL, AND COMPACTED AS STATED ABOVE. 3. COMPACTED SUBBASE SHALL BE UNIFORM & LEVELED. PROVIDE 6" MINIMUM CRUSHED STONE OR GRAVEL COMPACTED IN 3" LIFTS ABOVE COMPACTED SOIL. GRAVEL SHALL BE NATURAL OR CRUSHED WITH 100% PASSING 1" SIEVE. COMPACTION EQUIPMENT: HAND OPERATED DOUBLE DRUM, VIBRATORY ROLLER, VIBRATORY PLATE COMPACTOR OR JUMPING JACK COMPACTOR. S/G S/N SYMBOLS M AGL ABOVE GRADE LEVEL BTS BASE TRANSCEIVER STATION (E) EXISTING NEW NEW MIN MINIMUM N.T.S. NOT TO SCALE REF REFERENCE RF RADIO FREQUENCY TYP TYPICAL REQ REQUIRED EGR EQUIPMENT GROUND RING AWG AMERICAN WIRE GAUGE CRGB MASTER GROUND BAR [MASTER GROUND BAR] EG EQUIPMENT GROUND BCW BARE COPPER WIRE SIAD SMART INTEGRATED ACCESS DEVICE GEN GENERATOR IGR INTERIOR GROUND RING [HALO] RBS RADIO BASE STATION SOLID GROUND BUS BAR SOLID NEUTRAL BUS BAR SUPPLEMENTAL GROUND BAR 2-POLE THERMAL-MAGNETIC CIRCUIT BREAKER SINGLE-POLE THERMAL-MAGNETIC CIRCUIT BREAKER CHEMICAL GROUND ROD GROUND ROD = 4893.48 = 4892.08 BLDG= 4905.16 BLDG= 4904.48 BLDG= 4904.28 FV S EP= 4895.74 EP= 4896.90 TOE= 4895.34 TOP= 4896.70 TOE= 4895.32 EDR= 4895.20 EDR1= 4894.92 CONC= 4895.61 FV S ET GM WV WV FO FO FO FO FO FO FO FO EV APN: 8720106001 APN: 8720105013 APN: 8720105011 APN: 8720105012 (E) 32.5' BUILDING (E) 10.5' BLDG. D/W (E) OVERHANG (E) 11.5' SHEDS D/W (E) BUILDING (E) GATE (E) 6' WROUGHT IRON FENCE (E) 9' CHAIN LINK FENCE (E) 8' CHAIN LINK FENCE OLD LOT LINE D/W REBAR (E) 6' WROUGHT IRON FENCE REBAR REBAR REBAR X ROW ROW ROW UG UG UG UG TX/RX2 TX/RX1 TX MON2 TX MON1 TX/RX2 TX/RX1 F F F F F F TX MON2 MON1 F TX/RX2 TX/RX1 TX MON2 TX MON1 UG L-1 LANDSCAPE PLAN REV DATE DESCRIPTION BY A 12/21/16 90% ZONING CDA 0 01/05/17 FINAL ZONING JMA 1 08/14/17 FINAL ZONING KM 2 02/14/18 PROJECT REDESIGN CGS 20151294205 CDA KF 11"x17" SCALE: 3/64" = 1'-0" 24"x36" SCALE: 7/64" = 1'-0" C L E S U L A C L E C O N S U L T I N G , I N C . I N C . P FV FV X X X X S S ET GM X X X X X X X X X X X X X X X X X X X X X X X X X X X ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW UG UG UG UG UG UG UG UG UG UG UG UG T X/RX2 TX/RX1 TX MON2 TX MON1 TX/RX2 TX/RX1 F F F TX MON2 MON1 TX/RX2 TX/RX1 TX MON2 X X X ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW UG UG UG UG UG UG UG UG UG UG UG UG UG UG UG F F F F F F F F F F F F F F F F F F F F F F F F F F F UG UG UG UG UG UG Z-2 FTC PARKWOOD ENLARGED SITE PLAN AND ANTENNA PLAN 20151294205 CDA KF REV DATE DESCRIPTION BY A 12/21/16 90% ZONING CDA 0 01/05/17 FINAL ZONING JMA 1 08/14/17 FINAL ZONING KM 2 02/14/18 PROJECT REDESIGN CGS 11"x17" SCALE: 3/16" = 1'-0" ENLARGED SITE PLAN 24"x36" SCALE: 3/8" = 1'-0" 1 SHEET TITLE PREPARED FOR: CHECKED BY: DRAWN BY: PROJECT NO: CONSULTING FIRM 3 INVERNESS DRIVE E STE 200 ENGLEWOOD, CO 80112 Construction - Project Management - Site Development 3131 S. VAUGHN WAY, #550 AURORA, CO 80014 FINAL FOR ZONING ONLY SHEET NUMBER PENETRATIONS RRH ANTENNAS FIBER POWER HYBRID & COAX CABLES 2025 SHARP POINT DR., FT COLLINS, CO 80525 PROPOSED 20'-0" ACCESS/UTILITY EASEMENT PROPOSED PONDEROSA PINE TX/RX2 TX/RX1 TX MON2 TX MON1 TX/RX2 TX/RX1 TX MON2 TX MON1 TX/RX2 TX/RX1 T X MON2 TX MON1 Z-3 ANTENNA PLAN REV DATE DESCRIPTION BY A 12/21/16 90% ZONING CDA 0 01/05/17 FINAL ZONING JMA 1 08/14/17 FINAL ZONING KM 2 02/14/18 PROJECT REDESIGN CGS 20151294205 CDA KF 11"x17" SCALE: 1/4" = 1'-0" 24"x36" SCALE: 1/2" = 1'-0" SHEET TITLE PREPARED FOR: CHECKED BY: DRAWN BY: PROJECT NO: CONSULTING FIRM 3 INVERNESS DRIVE E STE 200 ENGLEWOOD, CO 80112 Construction - Project Management - Site Development 3131 S. VAUGHN WAY, #550 AURORA, CO 80014 FINAL FOR ZONING ONLY SHEET NUMBER PENETRATIONS RRH ANTENNAS FIBER POWER HYBRID & COAX CABLES FTC PARKWOOD 2025 SHARP POINT DR., FT COLLINS, CO 80525 SECTOR PLUMBING DIAGRAM 1 C L E S U L A C L E C O N S U L T I XX X HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX HFLX X X 11"x17" SCALE: 1/8" = 1'-0" 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0" 24"x36" SCALE: 1/4" = 1'-0" Z-4 20151294205 FTC PARKWOOD CDA KF ELEVATIONS REV DATE DESCRIPTION BY A 12/21/16 90% ZONING CDA 0 01/05/17 FINAL ZONING JMA 1 08/14/17 FINAL ZONING KM 2 02/14/18 PROJECT REDESIGN CGS EXISTING GRADE 0'-0" A.G.L. -- 4893'-0" NAVD88 PROPOSED VERIZON CABINETS MOUNTED TO PROPOSED STEEL PLINTH (2) PROPOSED VERIZON OVP MOUNTED ON ANTENNA MOUNT PROPOSED VERIZON REMOTE RADIO HEAD, (4) PER SECTOR FOR (3) SECTORS PROPOSED VERIZON SECTOR FRAME W/(4) ANTENNA PIPE MOUNTS PROPOSED VERIZON ANTENNAS (4) PER SECTOR FOR (3) SECTORS PROPOSED SOUTH ELEVATION 1 PROPOSED EAST ELEVATION 2 PROPOSED 65'-0" TALL CO-LOCATABLE MONOPINE *MONOPINE NOTE: · ANTENNAS TO BE ENCLOSED IN RF FRIENDLY SOCK TO MATCH COLOR OF MONOPINE · FAUX BARK TO BE INSTALLED THROUGHOUT ENTIRE TOWER HEIGHT *MONOPINE NOTE: · ANTENNAS TO BE ENCLOSED IN RF FRIENDLY SOCK TO MATCH COLOR OF MONOPINE · FAUX BARK TO BE INSTALLED THROUGHOUT ENTIRE TOWER HEIGHT (2) PROPOSED VERIZON HYBRID CABLE(S) ROUTED ALONG INTERIOR OF PROPOSED MONOPINE SHEET TITLE PREPARED FOR: CHECKED BY: DRAWN BY: PROJECT NO: CONSULTING FIRM 3 INVERNESS DRIVE E STE 200 ENGLEWOOD, CO 80112 Construction - Project Management - Site Development 3131 S. VAUGHN WAY, #550 AURORA, CO 80014 FINAL FOR ZONING ONLY SHEET NUMBER PENETRATIONS RRH ANTENNAS FIBER POWER HYBRID & COAX CABLES 2025 SHARP POINT DR., FT COLLINS, CO 80525 PROPOSED VERIZON GPS ANTENNA PROPOSED 30KW VERIZON DIESEL GENERATOR ON PROPOSED CONCRETE SLAB PROPOSED 10'-0" TALL VERIZON CANOPY ABOVE SLAB PROPOSED VERIZON FIBER JUNCTION BOX ON PROPOSED H-FRAME PROPOSED VERIZON 200A OUTDOOR RATED INTEGRATED LOAD CENTER ON PROPOSED H-FRAME TOP OF PROPOSED MONPINE ELEVATION 65'-0" A.G.L -- 4958'-0" NAVD88 CENTERLINE OF PROPOSED VERIZON ANTENNAS 57'-0" A.G.L -- 4950'-0" NAVD88 TOP OF PROPOSED VERIZON ANTENNAS ELEVATION 60'-0" A.G.L -- 4953'-0" NAVD88 PROPOSED VERIZON 6'-0" TALL PAINTED WOODEN FENCE ENCLOSURE EXISTING TREES TO REMAIN PROPOSED ELECTRICAL METER AND DISCONNECT MOUNTED TO PROPOSED FENCE W/ UNISTRUT TOP OF PROPOSED MONPINE ELEVATION 65'-0" A.G.L -- 4958'-0" NAVD88 CENTERLINE OF PROPOSED VERIZON ANTENNAS 57'-0" A.G.L -- 4950'-0" NAVD88 TOP OF PROPOSED VERIZON ANTENNAS ELEVATION 60'-0" A.G.L -- 4953'-0" NAVD88 (2) PROPOSED VERIZON OVP MOUNTED ON ANTENNA MOUNT PROPOSED VERIZON REMOTE RADIO HEAD, (4) PER SECTOR FOR (3) SECTORS PROPOSED VERIZON ANTENNAS (4) PER SECTOR FOR (3) SECTORS PROPOSED VERIZON SECTOR FRAME W/(4) ANTENNA PIPE MOUNTS (2) PROPOSED VERIZON HYBRID CABLE(S) ROUTED ALONG INTERIOR OF PROPOSED MONOPINE PROPOSED VERIZON 6'-0" TALL PAINTED WOODEN FENCE ENCLOSURE PROPOSED VERIZON GPS ANTENNA PROPOSED 10'-0" TALL VERIZON CANOPY ABOVE PROPOSED SLAB PROPOSED VERIZON 200A OUTDOOR RATED INTEGRATED LOAD CENTER AND PROPOSED FIBER JUNCTION BOX ON PROPOSED H-FRAME EXISTING FENCING TO REMAIN EXISTING FENCING TO REMAIN PROPOSED 65'-0" TALL CO-LOCATABLE MONOPINE (2) PROPOSED VERIZON HYBRID CABLE(S) ROUTED IN (N) UNDERGROUND CONDUITS TO PROPOSED MONOPINE EXISTING GRADE 0'-0" A.G.L. -- 4893'-0" NAVD88 PROPOSED VERIZON FIBER JUNCTION BOX ON PROPOSED H-FRAME PROPOSED VERIZON 200A OUTDOOR RATED INTEGRATED LOAD CENTER ON PROPOSED H-FRAME PROPOSED ELECTRICAL METER AND DISCONNECT MOUNTED TO PROPOSED FENCE W/ UNISTRUT PROPOSED VERIZON 12" CABLE TRAY BOTTOM OF BRANCHES 15' A.G.L BOTTOM OF BRANCHES 15' A.G.L PROPOSED 18"WIDE x 6" THICK CONCRETE FOOTING W/ SITEPRO1 P/N SLPR4 CUT 18" TO FIT PROPOSED FAUX BARK PROPOSED FAUX BARK N G , I N C . I N C . P I NN A C L E C O N N AC L E CON S U L T I N I N G , I N C . P I NNA C . P I N E C O . AZIMUTH 240 ° AZIMUTH 0 ° (2) PROPOSED VERIZON OVP MOUNTED ON ANTENNA MOUNT PROPOSED VERIZON REMOTE RADIO HEAD, STACKED, (4) PER SECTOR FOR (3) SECTORS PROPOSED VERIZON SECTOR FRAME W/ (4) ANTENNA PIPE MOUNTS PROPOSED VERIZON PANEL ANTENNAS (4) PER SECTOR FOR (3) SECTORS PROPOSED 65'-0" TALL MONOPINE NOTE: ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE *IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH RF DEPARTMENT PRIOR TO INSTALLING ANTENNAS. PROPOSED COAXIAL CABLE TABLE SECTOR LENGTH QTY. SIZE TYPE ALPHA BETA ±100' 2 1-1/4"Ø HYBRID CABLE GAMMA PROPOSED ANTENNA TABLE SECTOR RAD CENTER AZIMUTH QTY. MOUNT TYPE ANTENNA TYPE ALPHA 57'-0" 0° 4 BETA 57'-0" 120° 4 T-ARM PANEL GAMMA 57'-0" 240° 4 OUTLINE OF PROPOSED MONOPALM AZIMUTH 120 ° 6" (TYP) 2'-0" (TYP) 2'-0" (TYP) 2'-0" (TYP) 6" (TYP) 7'-2" (TYP) ANTENNA PLAN 2 TREE PROPOSED 65'-0" TALL CO-LOCATABLE MONOPINE PROPOSED VERIZON GPS ANTENNA PROPOSED VERIZON FIBER JUNCTION BOX ON PROPOSED UNI-STRUT PROPOSED VERIZON 200A OUTDOOR RATED INTEGRATED LOAD CENTER ON PROPOSED UNI-STRUT PROPOSED VERIZON WIRELESS EQUIPMENT LEASE AREA - 15'-0"X35'-0" PROPOSED 6'-0" TALL WOODEN FENCE (15'-0" X 35'-0") PAINTED VAN DYKE BROWN OR EQUIVELANT PROPOSED VERIZON 9'-0" x 10'-6" STEEL CANOPY PROPOSED 30KW VERIZON DIESEL GENERATOR MOUNTED TO PROPOSED CONCRETE PAD PROPOSED PONDEROSA PINE TREE PROPOSED VERIZON ELECTRICAL METER MOUNTED TO EXTERIOR OF PROPOSED FENCE WITH UNI-STRUT PROPOSED VERIZON ELECTRICAL DISCONNECT MOUNTED TO EXTERIOR OF PROPOSED FENCE WITH UNI-STRUT PROPOSED 12'-0" ACCESS GATES PROPOSED TECH LIGHTING MOUNTED TO PROPOSED CANOPY POST PROPOSED GRAVEL AREA PROPOSED 5'-0" UTILITY EASEMENT PROPOSED VERIZON 10'-0"x16'-0" CONCRETE PAD WITH PREFABRICATED SUN-WEST 2-BAY PLINTH PROPOSED VERIZON RF CABINET PROPOSED VERIZON PDF CABINET PROPOSED TRANSFORMER BY UTILITY COMPANY INSIDE 10X10 UTILITY EASEMENT PROPOSED POWER WIRING FROM PROPOSED TRANSFORMER PROPOSED FIBER PROPOSED TECH LIGHTING MOUNTED TO PROPOSED CANOPY POST NEW VZW 525 SQ. FT. LEASE AREA NEW VZW 7789 SQ. FT. ACCESS/UTILITY EASEMENT NEW VZW 256 SQ. FT. UTILITY EASEMENT NEW LEASE AND EASEMENT COLOR LEGEND 18" WIDE x 6" THICK CONCRETE FOOTING W/ SITEPRO1 P/N SLPR4 CUT 18" TO FIT PROPOSED 12" CABLE TRAY HATCHING INDICATES 3'-0" OF AIRSPACE AROUND PROPOSED GENERATOR(TYP.) TRENCH PROPOSED POWER TO ILC, GENERATOR & EQUIPMENT CABINET HATCH INDICATES 3' OF AIRSPACE IN FRONT OF PROPOSED ILC 3'-0" C L E S U L A C L E C O N S U L T I N G , I N C . I N C . P I NN A C L E C O N NAC L E C O N S U L TI N IN G , I N C . P I N N AC . P I N E C O . 16'-0" CONCRETE PAD 10'-0" CONCRETE PAD TX MON1 Z-1 FTC PARKWOOD SITE PLAN 3 Z-2 SITE PLAN 16' 8' 0" 16' 1 24"x36" SCALE: 1" = 16' 11"x17" SCALE: 1" = 32' 20151294205 CDA KF REV DATE DESCRIPTION BY A 12/21/16 90% ZONING CDA 0 01/05/17 FINAL ZONING JMA 1 08/14/17 FINAL ZONING KM 2 02/14/18 PROJECT REDESIGN CGS APN: 08720105013 ZONING: I, DEVELOPING INDUSTRIAL PROPOSED VERIZON WIRELESS EQUIPMENT LEASE AREA - 15'-0"X35'-0" SHEET TITLE PREPARED FOR: CHECKED BY: DRAWN BY: PROJECT NO: CONSULTING FIRM 3 INVERNESS DRIVE E STE 200 ENGLEWOOD, CO 80112 Construction - Project Management - Site Development 3131 S. VAUGHN WAY, #550 AURORA, CO 80014 FINAL FOR ZONING ONLY SHEET NUMBER PENETRATIONS RRH ANTENNAS FIBER POWER HYBRID & COAX CABLES 2025 SHARP POINT DR., FT COLLINS, CO 80525 PROPOSED VERIZON WIRELESS 2' x 3' FIBER VAULT PROPOSED 5'-0" VERIZON WIRELESS UTILITY EASEMENT PROPOSED 65'-0" CO-LOCATABLE MONOPINE FOR PROPOSED VERIZON ANTENNAS EXISTING BUILDING PROPOSED 20'-0" WIDE VERIZON ACCESS EASEMENT EXISTING GATE OLD LOT LINE EXISTING FIELD MIDPOINT DRIVE SHARP POINT DRIVE EXISTING FENCING EXISTING PROPERTY LINE EXISTING BUILDING EXISTING TRAILER EXISTING PARKING PROPOSED 60' FIRE TRUCK TURN-AROUND WITH 35' TURNING RADIUS R35'-0" 60'-0" FIRETRUCK TURN-AROUND 60'-0" FIRETRUCK TURN-AROUND R35'-0" 20'-0" ACCESS / UTILITY EASEMENT 20'-0" ACCESS / UTILITY EASEMENT PROPOSED 66'-0" R.O.W. IN REGARDS TO CONSTRUCTION OF THIS SITE, THE PUBLIC RIGHT-OF-WAY SHALL NOT BE USED FOR STAGING OR STORAGE OF MATERIALS OR EQUIPMENT ASSOCIATED WITH THE DEVELOPMENT, NOR SALL IT BE USED FOR PARKING BY ANY CONTRACTORS, SUBCONTRACTORS, OR OTHER PERSONNEL WORKING FOR OR HIRED BY THE DEVELOPER TO CONSTRUCT DEVELOPMENT 66'-0" SETBACK FROM FENCE TOWER SETBACK NORTH 135'-0" EAST 117'-0" SOUTH 125'-0" WEST 76'-0" PROPOSED UG CONDUIT FOR PROPOSED POWER (BY UTILITY COMPANY) PROPOSED 10'-0" X 10'-0" UTILITY EASEMENT FOR PROPOSED TRANSFORMER (BY UTILITY COMPANY) EXISTING 150 KVA TRANSFORMER NEW VZW 525 SQ. FT. LEASE AREA NEW VZW 7789 SQ. FT. ACCESS/UTILITY EASEMENT NEW VZW 256 SQ. FT. UTILITY EASEMENT NEW LEASE AND EASEMENT COLOR LEGEND C L E S U L A C L E C O N S U L T I N G , I N C . I N C . P I NNA C L E C O N NAC L E C O N S U L T I N I N G , I NC. P I N N AC . P IN E C O . I NN A C L E C O N NAC L E C O N S U L TI N IN G , I N C . P I N N AC . P I N E C O . SHEET TITLE PREPARED FOR: CHECKED BY: DRAWN BY: PROJECT NO: CONSULTING FIRM 3 INVERNESS DRIVE E STE 200 ENGLEWOOD, CO 80112 Construction - Project Management - Site Development 3131 S. VAUGHN WAY, #550 AURORA, CO 80014 FINAL FOR ZONING ONLY SHEET NUMBER PENETRATIONS RRH ANTENNAS FIBER POWER HYBRID & COAX CABLES FTC PARKWOOD 2025 SHARP POINT DR., FT COLLINS, CO 80525 TREE PLANTING DETAIL DO NOT CUT TREE LEADER, PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND INJURED BRANCHES. PLACE 6' DIA. MIN. MULCH RING AROUND TREE. SPECIFIED MATERIALS VARY AND SHOULD NOT CONTACT TREE TRUNK. SET STAKES IN FIRM SOIL, 3 STAKES PER TREE. USE WIRE AND FASTENERS TO ALLOW 3"-4" OF TRUNK MOVEMENT. FLAG WIRE WITH 1/2" DIA. WHITE PVC PIPE. BACKFILL PER SPECS. PLACE ROOTBALL 3"-4" HIGH WITH RESPECT TO GRADE PER SPECS. DO NOT COVER ROOTBALL WITH SOIL. OBTAIN APPROVAL OF TREE HEIGHT PRIOR TO FINAL PLANTING. REMOVE WIRE BASKET AROUND ROOTBALL AND PEEL BACK BURLAP 1/3. SCARIFY ALL SIDES OF HOLE. 3X ROOTBALL DIA. 6" GENERAL LANDSCAPE NOTES: RESPONSIBILITY OF MAINTENANCE MAINTENANCE OF ALL PLANTINGS AND IRRIGATION, SHALL BE THE RESPONSIBILITY OF THE EXISTING LANDLORD. CONSTRUCTION NOTES: 1. PRIOR TO BEGINNING WORK ON THE PROJECT, THE LANDSCAPE CONTRACTOR SHALL REVIEW THE PROJECT IN THE FIELD WITH THE OWNER'S REPRESENTATIVE. 2. THOUGH THE LANDSCAPE CONTRACTOR MAY NOTIFY THE OWNER'S REPRESENTATIVE IF DISCREPANCIES OCCUR BETWEEN THE DRAWINGS AND THE SITE, FINAL CLARIFICATION SHALL BE BY THE CITY. THE APPROVED SITE DEVELOPMENT PLAN IS THE CONTROLLING DOCUMENT. 3. ALL PLANTING AREAS ARE TO HAVE WEEDS AND COMPETITIVE VEGETATION REMOVED PRIOR TO PREPARATION FOR PLANTING. 4. ALL EXISTING PLANT MATERIALS SHALL BE PROTECTED DURING CONSTRUCTION. DAMAGED MATERIALS SHALL BE REPLACED IN KIND AT THE CONTRACTOR'S EXPENSE. 5. PLANT QUANTITIES ARE PROVIDED FOR CONTRACTOR'S CONVENIENCE ONLY, PLANS SHALL TAKE PRECEDENCE. 6. ANY PLANT SUBSTITUTIONS MUST BE APPROVED BY THE CITY. SUBSTITUTIONS ARE NOT PERMITTED UNLESS AUTHORIZED. THE APPROVED SITE DEVELOPMENT PLAN IS THE CONTROLLING DOCUMENT. 7. IT IS THE LANDSCAPE CONTRACTOR'S RESPONSIBILITY TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO COMMENCEMENT OF PLANTING OPERATIONS. 8. ALL SHRUB PLANTING AREAS SHALL BE TOP DRESSED WITH GRAVEL MULCH (TO MATCH EXISTING) OVER DE WITH PRO-5 WEED CONTROL FABRIC, UNLESS NOTED OTHERWISE. LANDSCAPE LEGEND: GROUND COVERS CRUSHED ROCK (3-INCH DEPTH OVER DE WITT PRO-5 WEED CONTROL FABRIC) OR EQUAL QTY. 2 FAMILY NAME: PINUS PONDEROSA FOLIAGE: GREEN TO YELLOWISH, GREEN NEEDLES MATURE HEIGHT: 50 - 60 FEET MATURE SPREAD: 10 - 12 FEET SOIL: WIDELY ADAPTABLE ZONES: 3-7 MATURE FORM: PYRAMIDIAL GROWTH RATE: MEDIUM SUN EXPOSURE: FULL SUN FALL COLOR: STOUT GREEN NEEDLES WITH PINE CONES COMMON NAME: PONDEROSA PINE PONDEROSA PINE CRUSH ROCK BASE 1/2" NEW CRUSHED ROCK BASE NEW 6'-0" TALL WOODEN FENCE ENCLOSURE NEW VERIZON WIRELESS EQUIPMENT LEASE AREA NEW MONOPINE WITH NEW ANTENNAS NEW CONCRETE SLAB WITH CANOPY NEW TREES TO BE INSTALLED (2 TOTAL) LANDSCAPE PLAN 1 NEW VZW 525 SQ. FT. LEASE AREA NEW VZW 7789 SQ. FT. ACCESS/UTILITY EASEMENT NEW VZW 256 SQ. FT. UTILITY EASEMENT NEW LEASE AND EASEMENT COLOR LEGEND REBAR REBAR (E) 8' CHAIN LINK FENCE LESSOR'S PARCEL LINE LESSOR'S PARCEL LINE 4894 4894 4893 4894 4893 4894 4894 4895 4897 4895 4895 4894 4895 4896 4896 4895 4896 4896 4895 4896 4895 4896 4895 4896 4895 4895 4895 4896 4896 4896 4895 4895 4895 4896 4896 4895 4897 4897 4897 4896 4896 4894 (E) SHED 4896 SHARP POINT DRIVE MIDPOINT DRIVE (E)60' R/W (E) 60' R/W 4893 4893 PV= 4894.73 NG= 4894.52 NG= 4894.51 4894.30 NG= 4893.56 NG= NG= 4893.30 NG= 4892.99 NG= 4893.89 NG= 4893.88 NG= 4894.48 4894.24 NG= NG= 4894.43 NG= 4895.12 NG= 4894.36 NG= 4896.10 NG= 4894.31 NG= 4895.34 NG= 4894.78 NG= 4894.73 NG= 4895.57 NG= 4895.53 NG= 4896.41 TBC= 4894.26 28 TBC= 4893.90 TBC= 4893.34 TBC= 4892.50 TBC= 4892.52 TBC= 4892.59 TBC= 4893.98 5 5 UTILITY ESMT. 5 (E) UTILITY ESMT. 5 L1 L=7 0 . 7 5, R =2 4 8 . 9 8 D = 1 6 ° 1 6 ' 5 2 " L=23.56, R=15.00 D=89°59'33" N0° 13' 25"W 238.55' L=2 0 6 . 1 8 , R = 74 3 . 0 5 D = 1 5 ° 5 3 ' 5 4 " 275.13' 245.83' S42° 37' 03"E 311.39' N47° 22' 57"E 520.96' S73° 56' 33"E 342.06' (P) 66' R/W (P) 66' R/W L2 L3 L4 L11 L12 L13 P.O.B. (P) LESSEE A.U.E. UGE UGE UGE GAS UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE GAS GAS GAS GAS GAS GAS GAS GAS T T T T T T T T T T T T T T T T 4894 4894 4893 NG= 4892.99 NG= 4893.89 (E) 40' TREE (E) 40' TREE (E) 40' TREE (E) 45' TREE P.O.B. (P) LESSEE LEASE AREA P.O.B. (P) 5' LESSEE UTILITY ESMT. #1 (P) 20' LESSEE ACCESS/UTILITY ESMT. (P) LESSEE LEASE AREA (P) POLE LOCATION (CENTER OF GEODETIC COORDINATES) (P) 5' LESSEE UTILITY ESMT. #1 NATURAL GROUND S73° 56' 33"E 342.06' C1 L5 L6 L7 C2 L8 L9 L10 L14 L15 L16 L17 L18 L19 L20 L21 P.O.B. (P) 10' LESSEE UTILITY ESMT. #2 (P) 10' LESSEE UTILITY ESMT. #2 LOTS 13 AND 14, PROSPECT INDUSTRIAL PARK, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. LESSOR'S LEGAL DESCRIPTION MAGNETIC 08° 28' BOUNDARY DETAIL SCALE: 1" = 40' POSITION OF GEODETIC COORDINATES LATITUDE 40° 33' 36.65" NORTH (NAD83) LONGITUDE 105° 01' 39.97" WEST (NAD83) ELEVATION @ GROUND= 4893.0 (NAVD88) 1. ELEVATIONS SHOWN HEREON ARE REPRESENTED IN NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) ESTABLISHED FROM GPS DERIVED ELLIPSOID HEIGHTS, APPLYING GEOID 09 SEPARATIONS CONSTRAINING TO NGS CORS STATIONS PROVIDED IN THE "ONLINE POSITIONING USER SERVICE" (OPUS) SOLUTION FOR THIS SPECIFIC SITE. 2. BEARINGS SHOWED HEREON ARE BASED UPON U.S. STATE PLANE NAD83 COORDINATE SYSTEM COLORADO STATE PLANE COORDINATE ZONE NORTH, DETERMINED BY GPS OBSERVATIONS. 3. FIELD WORK FOR THIS PROJECT WAS PERFORMED ON 06/08/16. PROJECT META DATA 1. ALL TITLE INFORMATION IS BASED UPON A COMMITMENT FOR TITLE INSURANCE PREPARED BY OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY, ORDER NO.: ACT25141771 EFFECTIVE DATE: 07/05/2016.. 2. SURVEYOR HAS NOT PERFORMED A SEARCH OF PUBLIC RECORDS TO DETERMINE ANY DEFECT IN TITLE. 3. THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF THE PROPERTY. 4. SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THEIR LOCATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. DECLINATION SURVEYOR NOTES 1 07/12/16 PRELIMINARY SHEET NO. REVISION: REVISIONS PROJECT No. SITE NAME: SITE ADDRESS: SHEET TITLE: FIELD BY: DRAWN BY: CHECKED BY: NO. DATE DESCRIPTION REUSE OF DOCUMENT THE IDEAS & DESIGN INCORPORATED HEREON, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RLF CONSULTING, LLC. JTS JTJ RLF 10008328 FTC PARKWOOD 2025 SHARP POINT DR. FORT COLLINS CO, 80524 SITE SURVEY LS-1 SURVEY DETAIL THIS SHEET 3 INVERNESS DRIVE EAST, STE. 200 ENGLEWOOD, CO. 80112 Construction - Project Management - Site Development 5. EASEMENTS, CONDITIONS, COVENANTS, RESTRICTIONS, RESERVATIONS AND NOTES ON THE PLAT OF PROSPECT INDUSTRIAL PARK RECORDED APRIL 25, 1979 AT RECEPTION NO. 303647. SCHEDULE B EXCEPTIONS 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 NORTH THE PROPOSED LEASE PREMISES SHOWN HEREON APPEAR TO BE WITHIN FLOOD ZONE "X" AS DELINEATED ON THE FEDERAL EMERGENCY MANAGEMENT AGENCY FIRM MAP NO. 08069C0992G DATED 05/02/12. FLOOD ZONE "X" IS DEFINED AS: AREAS DETERMINED TO BE OUTSIDE 500-YEAR FLOODPLAIN; DETERMINED TO BE OUTSIDE THE 1% AND 0.2% ANNUAL CHANCE FLOODPLAINS. FLOOD ZONE DESIGNATION C O L O R A D O L I C E N S E D P R O F E S S I O N A L L A N D S U R V E Y O R R Y A N L . F I D L E R 38207 PROSPECT RD. TIMBERLINE RD. 9 11 DRAKE RD. SHARP POINT DR. MIDPOINT DR. PROJECT AREA FOUND AS NOTED HANDICAP SANITARY SEWER MANHOLE GAS METER WATER VALVE RIGHT-OF-WAY LINE ELECTRICAL TRANSFORMER TELEPHONE PEDESTAL ELECTRIC VAULT CHAIN LINK FENCE PROPERTY LINE PROPERTY LINE (OTHER) WROUGHT IRON FENCE SPOT ELEVATION D/W TBC R/W PV TOP BACK OF CURB ACCESS DRIVEWAY RIGHT OF WAY ASPHALT NG NATURAL GRADE BLDG TOP OF BUILDING 1419.18 U/G ELECTRIC LINE U/G FIBER OPTIC LINE U/G GAS LINE SANITARY SEWER LINE WATER LINE UGE UGE FO FO FO GAS GAS SS SS SS W W W T T T U/G TELECOMMUNICATION LINE DECIDUOUS TREE ET EV S FV FIBER VAULT GM STREET LIGHT W/ MAST ARM WV 2 08/02/16 REVISION ITEMS 1 THRU 4, 6, AND 7 OF THE CLIENT PROVIDED TITLE REPORT DO NOT CONTAIN GRAPHICALLY PLOTTABLE EASEMENTS, SETBACKS, RESTRICTIONS OR OTHER ENCUMBRANCES. THE SURVEYOR CANNOT GUARANTEE THAT NON-PLOTTABLE ENCUMBRANCES DO NOT EXIST THAT MAY AFFECT THE SUBJECT LEASED PREMISES. A PORTION OF LOTS 13 AND 14, PROSPECT INDUSTRIAL PARK, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, DESCRIBED AS FOLLOWS: COMMENCING AT THE EASTERNMOST SOUTHEAST CORNER OF SAID LOT 14 FROM WHICH AN ANGLE POINT ON THE EAST LINE OF SAID LOT 13 BEARS NORTH 0° 13' 25" WEST 238.55 FEET; THENCE NORTH 00°13'25" WEST ALONG THE EAST LINE OF LOTS 13 AND 14, 131.78 FEET TO THE POINT OF BEGINNING. THENCE SOUTH 89°46'35" WEST, 9.01 FEET; THENCE NORTH 42°35'39" WEST, 134.79 FEET; THENCE SOUTH 47°24'37" WEST, 90.13 FEET TO THE BEGINNING OF A NON TANGENT CURVE TO THE RIGHT; THENCE WESTERLY ALONG SAID CURVE TO THE RIGHT HAVING A RADIUS OF 35.00 FEET, WITH A CHORD BEARING NORTH 87°36'16" WEST, 49.51 FEET, THROUGH A CENTRAL ANGLE OF 90°01'34", AN ARC LENGTH OF 54.99 FEET; THENCE NORTH 42°32'28" WEST, 5.02 FEET; THENCE SOUTH 47°22'57" WEST, 20.00 FEET; THENCE SOUTH 42°37'03" EAST, 5.00 FEET TO THE BEGINNING OF A CURVE TO THE RIGHT; THENCE SOUTHERLY ALONG SAID CURVE TO THE RIGHT HAVING A RADIUS OF 35.00 FEET, THROUGH A CENTRAL ANGLE OF 90°00'00", AN ARC LENGTH OF 54.98 FEET; THENCE SOUTH 47°22'57" WEST, 15.00 FEET; THENCE SOUTH 42°37'03" EAST, 20.00 FEET; THENCE NORTH 47°24'17" EAST, 174.98 FEET; THENCE SOUTH 42°39'37" EAST, 123.58 FEET; THENCE SOUTH 89°58'14" EAST, 17.86 FEET; THENCE NORTH 00°13'25" WEST, 20.04 FEET TO THE POINT OF BEGINNING. LESSEE ACCESS/UTILITY EASEMENT LEGAL DESCRIPTION A PORTION OF LOT 14, PROSPECT INDUSTRIAL PARK, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, DESCRIBED AS FOLLOWS: COMMENCING AT THE EASTERNMOST SOUTHEAST CORNER OF SAID LOT 14 FROM WHICH AN ANGLE POINT ON THE EAST LINE OF SAID LOT 13 BEARS NORTH 0° 13' 25" WEST 238.55 FEET; THENCE NORTH 00°13'25" WEST ALONG THE EAST LINE OF LOTS 13 AND 14, 131.78 FEET; THENCE SOUTH 89°46'35" WEST, 9.01 FEET; THENCE NORTH 42°35'39" WEST, 134.79 FEET; THENCE SOUTH 47°24'37" WEST, 90.13 FEET TO THE BEGINNING OF A NON TANGENT CURVE TO THE RIGHT; THENCE WESTERLY ALONG SAID CURVE TO THE RIGHT HAVING A RADIUS OF 35.00 FEET, WITH A CHORD BEARING NORTH 87°36'16" WEST, 49.51 FEET, THROUGH A CENTRAL ANGLE OF 90°01'34", AN ARC LENGTH OF 54.99 FEET; THENCE NORTH 42°32'28" WEST, 5.02 FEET; THENCE SOUTH 47°22'57" WEST, 20.00 FEET; THENCE SOUTH 42°37'03" EAST, 5.00 FEET TO THE BEGINNING OF A CURVE TO THE RIGHT; THENCE SOUTHERLY ALONG SAID CURVE TO THE RIGHT HAVING A RADIUS OF 35.00 FEET, THROUGH A CENTRAL ANGLE OF 90°00'00", AN ARC LENGTH OF 54.98 FEET; THENCE SOUTH 47°22'57" WEST, 15.00 FEET; THENCE SOUTH 42°37'03" EAST, 20.00 FEET TO THE POINT OF BEGINNING; THENCE NORTH 47°22'57" EAST, 35.00 FEET; THENCE SOUTH 42°37'03" EAST, 15.00 FEET; THENCE SOUTH 47°22'57" WEST, 35.00 FEET; THENCE NORTH 42°33'06" WEST, 10.79 FEET; THENCE NORTH 42°47'10" WEST, 4.21 FEET TO THE POINT OF BEGINNING. LESSEE LEASE AREA LEGAL DESCRIPTION A 5.00 FOOT WIDE STRIP OF LAND BEING PORTION OF LOT 14, PROSPECT INDUSTRIAL PARK, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, LYING 2.50 FEET ON EACH SIDE OF THE FOLLOWING DESCRIBED CENTERLINE: COMMENCING AT THE EASTERNMOST SOUTHEAST CORNER OF SAID LOT 14 FROM WHICH AN ANGLE POINT ON THE EAST LINE OF SAID LOT 13 BEARS NORTH 0° 13' 25" WEST 238.55 FEET; THENCE NORTH 00°13'25" WEST ALONG THE EAST LINE OF LOTS 13 AND 14, 131.78 FEET; THENCE SOUTH 89°46'35" WEST, 9.01 FEET; THENCE NORTH 42°35'39" WEST, 134.79 FEET; THENCE SOUTH 47°24'37" WEST, 90.13 FEET TO THE BEGINNING OF A NON TANGENT CURVE TO THE RIGHT; THENCE WESTERLY ALONG SAID CURVE TO THE RIGHT HAVING A RADIUS OF 35.00 FEET, WITH A CHORD BEARING NORTH 87°36'16" WEST, 49.51 FEET, THROUGH A CENTRAL ANGLE OF 90°01'34", AN ARC LENGTH OF 54.99 FEET; THENCE NORTH 42°32'28" WEST, 5.02 FEET; THENCE SOUTH 47°22'57" WEST, 20.00 FEET; THENCE SOUTH 42°37'03" EAST, 5.00 FEET TO THE BEGINNING OF A CURVE TO THE RIGHT; THENCE SOUTHERLY ALONG SAID CURVE TO THE RIGHT HAVING A RADIUS OF 35.00 FEET, THROUGH A CENTRAL ANGLE OF 90°00'00", AN ARC LENGTH OF 54.98 FEET; THENCE SOUTH 47°22'57" WEST, 15.00 FEET; THENCE SOUTH 42°37'03" EAST, 20.00 FEET; THENCE NORTH 47°22'57" EAST, 35.00 FEET; THENCE SOUTH 42°37'03" EAST, 15.00 FEET; THENCE SOUTH 47°22'57" WEST, 35.00 FEET; THENCE NORTH 42°33'06" WEST, 10.79 FEET TO THE POINT OF BEGINNING; THENCE SOUTH 47°06'02" WEST, 43.73 FEET TO THE POINT OF TERMINUS. SIDELINES SHALL BE LENGTHENED OR SHORTENED TO FORM ONE CONTIGUOUS PARCEL. LESSEE UTILITY EASEMENT #1 LEGAL DESCRIPTION 3 08/26/16 FINAL AND REVISION SURVEY DETAIL 4 01/03/17 REVISION 5 07/30/17 REVISION CURVE TABLE CURVE C1 C2 LENGTH 54.99 54.98 RADIUS 35.00 35.00 DELTA 90°01'34" 90°00'00" CHORD BRG. N87° 36' 16"W S2° 22' 57"W CHORD LENGTH 49.51 49.50 6 08/05/17 REVISION A 10.00 FOOT WIDE STRIP OF LAND BEING PORTION OF LOT 14, PROSPECT INDUSTRIAL PARK, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, LYING 5.00 FEET ON EACH SIDE OF THE FOLLOWING DESCRIBED CENTERLINE: COMMENCING AT THE EASTERNMOST SOUTHEAST CORNER OF SAID LOT 14 FROM WHICH AN ANGLE POINT ON THE EAST LINE OF SAID LOT 13 BEARS NORTH 0° 13' 25" WEST 238.55 FEET; THENCE NORTH 00°13'25" WEST ALONG THE EAST LINE OF LOTS 13 AND 14, 131.78 FEET; THENCE SOUTH 89°46'35" WEST, 9.01 FEET; THENCE NORTH 42°35'39" WEST, 134.79 FEET; THENCE SOUTH 47°24'37" WEST, 90.13 FEET TO THE BEGINNING OF A NON TANGENT CURVE TO THE RIGHT; THENCE WESTERLY ALONG SAID CURVE TO THE RIGHT HAVING A RADIUS OF 35.00 FEET, WITH A CHORD BEARING NORTH 87°36'16" WEST, 49.51 FEET, THROUGH A CENTRAL ANGLE OF 90°01'34", AN ARC LENGTH OF 54.99 FEET; THENCE NORTH 42°32'28" WEST, 5.02 FEET; THENCE SOUTH 47°22'57" WEST, 20.00 FEET; THENCE SOUTH 42°37'03" EAST, 5.00 FEET TO THE BEGINNING OF A CURVE TO THE RIGHT; THENCE SOUTHERLY ALONG SAID CURVE TO THE RIGHT HAVING A RADIUS OF 35.00 FEET, THROUGH A CENTRAL ANGLE OF 90°00'00", AN ARC LENGTH OF 54.98 FEET; THENCE SOUTH 47°22'57" WEST, 15.00 FEET; THENCE SOUTH 42°37'03" EAST, 20.00 FEET; THENCE NORTH 47°22'57" EAST, 35.00 FEET; THENCE SOUTH 42°37'03" EAST, 15.00 FEET; THENCE SOUTH 47°22'57" WEST, 35.00 FEET; THENCE NORTH 42°33'06" WEST, 10.79 FEET; THENCE SOUTH 47°06'02" WEST, 5.00 FEET TO THE POINT OF BEGINNING; THENCE SOUTH 42°37'03" EAST, 7.46 FEET TO THE POINT OF TERMINUS. SIDELINES SHALL BE LENGTHENED OR SHORTENED TO FORM ONE CONTIGUOUS PARCEL. LESSEE UTILITY EASEMENT #2 LEGAL DESCRIPTION LINE TABLE LINE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 LENGTH 131.78 9.01 134.79 90.13 5.02 20.00 5.00 15.00 20.00 174.98 123.58 17.86 20.04 35.00 15.00 35.00 10.79 4.21 43.73 5.00 7.46 BEARING N0° 13' 25"W S89° 46' 35"W N42° 35' 39"W S47° 24' 37"W N42° 32' 28"W S47° 22' 57"W S42° 37' 03"E S47° 22' 57"W S42° 37' 03"E N47° 24' 17"E S42° 39' 37"E S89° 58' 14"E N0° 13' 25"W N47° 22' 57"E S42° 37' 03"E S47° 22' 57"W N42° 33' 06"W N42° 47' 10"W S47° 06' 02"W S47° 06' 02"W S42° 37' 03"E 7 12/14/17 REVISION DISCONNECT SWITCH METER CADWELD TYPE CONNECTION COMPRESSION TYPE CONNECTION GROUNDING WIRE ABBREVIATIONS GENERAL NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR - GENERAL CONTRACTOR [CONSTRUCTION] OWNER - VERIZON WIRELESS OEM - ORIGINAL EQUIPMENT MANUFACTURE 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 4. DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE ONLY. 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 6. DELETED. 7. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONTRACTOR. 9. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS 10. THE SUBCONCTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 11. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OFF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 12. SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. 13. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE [ACI] 301. 14. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL HAVE 4000 PSI STRENGTH AT 28 DAYS UNLESS OTHERWISE SPECIFIED.ALL CONCRETING WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. 15. ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS. 16. CONSTRUCTION SHALL COMPLY WITH SPECIFICATION 25741-000-3APS-AOOZ-00002, "GENERAL CONSTRUCTION SERVICES. 17. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 18. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY SUBCONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK MAY NEED TO BE SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. 19. SINCE THE CELL SITE MAY BE ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO PERSONAL RF EXPOSURE MONITORS ARE REQUIRED TO BE WORN TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS. CONCRETE AND REINFORCING STEEL NOTES: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST-IN-PLACE CONCRETE. 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS,UNLESS NOTED OTHERWISE 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED UNLESS NOTED OTHERWISE 4. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH 3 IN. CONCRETE EXPOSED TO EARTH OR WEATHER: #6 AND LARGER 2 IN. #5 AND SMALLER & WWF 1-1/2 IN. CONCRETE NOT EXPOSED TO EARTH OR WEATHER, NOR CAST AGAINST THE GROUND: SLAB AND WALL 3/4 IN. BEAMS AND COLUMNS 1-1/2 IN. 5. A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, U.N.O., IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 6. POST INSTALLED ANCHORS SHALL BE PROVIDED IN ACCORDANCE WITH SPECIFICATION 3GS-T18-0013" SELECTION, DESIGN, INSTALLATION, INSPECTION AND TESTING OF ADHESIVE AND MECHANICAL EXPANSION ANCHORS FOR WIRELESS SITE FACILITIES". ANCHORS SHALL BE HILTI OR APPROVED EQUAL, INSTALLED, INSPECTED AND TESTED AS SHOWN ON THE DESIGN DRAWINGS. NO REINFORCING STEEL SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL. 7. CONCRETE CYLINDER TEST IS NOT REQUIRED FOR SLAB ON GRADE WHEN CONCRETE IS LESS THAN 50 CUBIC YARDS [2012 IBC 1705.3[3]] IN THAT EVENT THE FOLLOWING RECORDS SHALL BE PROVIDED BY THE CONCRETE SUPPLIER; [A] RESULTS OF CONCRETE CYLINDER TESTS PERFORMED AT THE SUPPLIER'S PLANT, [B] CERTIFICATION OF MINIMUM COMPRESSIVE STRENGTH FOR THE CONCRETE GRADE SUPPLIED. FOR GREATER THAN 50 CUBIC YARDS THE GC SHALL PERFORM THE CONCRETE CYLINDER TEST, TAKING THREE CYLINDERS FROM EACH TRUCK. GROUNDING NOTES: 1. THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING PROTECTION SYSTEM [AS DESIGNED AND INSTALLED] FOR STRICT COMPLIANCE WITH THE NEC [AS ADOPTED BY THE AHJ], THE SITE-SPECIFIC [UL, LPI, OR NFPA] LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. 2. ALL GROUND ELECTRODE SYSTEMS [INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER GES'S] SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTIAL RESISTANCE TO EARTH TESTING [PER IEEE 1100 AND 81] FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. TESTS SHALL BE PERFORMED IN ACCORDANCE WITH 24782-000-3PS-EG00-0001, DESIGN & TESTING OF FACILITY GROUNDING FOR CELL SITES. 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 5. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS; 2 AWS STRANDED COPPER FOR OUTDOOR BTS. 6. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 7. APPROVED ANTIOXIDANT COATINGS [I.E., CONDUCTIVE GEL OR PASTE] SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 8. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED WITH STAINLESS STEEL HARDWARE TO THE BRIDGE AND THE TOWER GROUND BAR. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 11. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 12. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE [E.G., NON-METALIC CONDUIT PROHIBITED BY LOCAL CODE] THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 13. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF ANSI/TIA 222. FOR TOWERS BEING BUILT TO REV G OF THE STANDARD, THE WIRE SIZE OF THE BURIED GROUND RING AND CONNECTIONS BETWEEN THE TOWER AND THE BURIED GROUND RING SHALL BE CHANGED FROM 2 AWG TO 2/0 AWG. IN ADDITION, THE MINIMUM LENGTH OF THE GROUND RODS SHALL BE INCREASED FROM 8 FEET TO 10 FEET. SITE WORK GENERAL NOTES: 1. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 2. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE SUBCONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. SUBCONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A] FALL PROTECTION B] CONFINED SPACE C] ELECTRICAL SAFETY D] TRENCHING & EXCAVATION. 3. ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND PROJECT SPECIFICATIONS. 4. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 5. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, OWNER AND/OR LOCAL UTILITIES. 6. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. 7. THE SUBCONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE VERIZON WIRELESS SPECIFICATION FOR SITE SIGNAGE. 8. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS EQUIPMENT AND TOWER AREAS. 9. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 10. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 11. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION. 12. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL JURISDICTION'S GUIDELINES FOR EROSION AND SEDIMENT CONTROL. MASONRY NOTES: 1. MASONRY WALLS SHALL BE CONSTRUCTED OF 8” STANDARD HOLLOW CONCRETE MASONRY UNITS SHALL CONFORMING TO ASTM C90, GRADE N, TYPE 1, F'M = 1,500 PSI, RUNNING BOND, MORTAR TYPE S, 1,800 PSI. GROUT SHALL BE 2,000 PSI. MECHANICALLY VIBRATE GROUT IN VERTICAL SPACES IMMEDIATELY AFTER POURING AND AGAIN ABOUT 5 MINUTES LATER. PROVIDE CLEANOUTS IF GROUT LIFT EXCEEDS 4'-0" IN BLOCK WALLS. MAXIMUM GROUT LIFT SHALL BE 8'-0". CONTROL JOINTS REQUIRED IN ALL WALLS GREATER THAN 24'-0" IN LENGTH. SPACE CONTROL JOINTS AT 24'-0” MAXIMUM. ELECTRICAL INSTALLATION NOTES: 1. WIRING, RACEWAY, AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC AND TELCORDIA. 2. SUBCONTRACTOR SHALL MODIFY EXISTING CABLE TRAY SYSTEM AS REQUIRED TO SUPPORT RF AND TRANSPORT CABLING TO THE NEW BTS EQUIPMENT. SUBCONTRACTOR SHALL SUBMIT MODIFICATIONS TO CONTRACTOR FOR APPROVAL. 3. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC AND TELCORDIA. 4. CABLES SHALL NOT BE ROUTED THROUGH LADDER-STYLE CABLE TRAY RUNGS. 5. EACH END OF EVERY POWER, GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE [3M BRAND, 1/2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL]. THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA, AND MATCH EXISTING INSTALLATION REQUIREMENTS. 6. POWER PHASE CONDUCTORS [I.E., HOTS]SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE [3M BRAND, 1/2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL]. PHASE CONDUCTOR COLOR CODES SHALL CONFORM WITH THE NEC & OSHA AND MATCH EXISTING INSTALLATION REQUIREMENTS.. 7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS [I.E., PANELBOARD AND CIRCUIT ID'S].. 8. PANELBOARDS [ID NUMBERS] AND INTERNAL CIRCUIT BREAKERS [CIRCUIT ID NUMBERS] SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. 9. ALL TIE WRAPS WHERE PERMITTED SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. USE LOW PROFILE TIE WRAPS. 10. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR [12 AWG OR LARGER], 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C [WET AND DRY] OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 11. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR [6 AWG OR LARGER], 600 V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C [WET AND DRY] OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 12. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED OUTDOORS, OR BELOW GRADE, SHALL BE SINGLE CONDUCTOR 2 AWG SOLID TINNED COPPER CABLE, UNLESS OTHERWISE SPECIFIED. 13. POWER WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE [12 AWG OR LARGER], 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C [WET AND DRY] OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS OTHERWISE SPECIFIED. 14. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRENUTS BY THOMAS AND BETTS [OR EQUAL]. LUGS AND WIRENUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 75°C [90°C IF AVAILABLE]. 15. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. 16. NEW RACEWAY OR CABLE TRAY WILL MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. 17. ELECTRICAL METALLIC TUBING [EMT] OR RIGID NONMETALLIC CONDUIT [I.E., RIGID PVC SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE] SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 18. ELECTRICAL METALLIC TUBING [EMT], ELECTRICAL NONMETALLIC TUBING [ENT], OR RIGID NONMETALLIC CONDUIT [RIGID PVC, SCHEDULE 40] SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 19. GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT [IMC] SHALL BE USED FOR OUTDOOR LOCATIONS ABOVE GRADE. 20. RIGID NONMETALLIC CONDUIT [I.E., RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80] SHALL BE USED UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC. 21. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT [LIQUID-TITE FLEX] SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 22. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. 23. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. 24. CABINETS, BOXES, AND WIREWAYS TO MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. 25. WIREWAYS SHALL BE EPOXY-COATED [GRAY] AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARD; SHALL BE PANDUIT TYPE E [OR EQUAL]; AND RATED NEMA 1 [OR BETTER] INDOORS, OR NEMA 3R [OR BETTER] OUTDOORS. 26. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPOXY-COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 [OR BETTER] INDOORS, OR NEMA 3R [OR BETTER] OUTDOORS. 27. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPOXY-COATED, OR NON-CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 [OR BETTER] INDOORS, OR WEATHER PROTECTED [WP OR BETTER] OUTDOORS. 28. NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 [OR BETTER] INDOORS, OR WEATHER PROTECTED [WP OR BETTER] OUTDOORS. 29. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE OWNER BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 30. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODS AND STANDARDS TO SAFEGUARD AGAINST LIFE AND PROPERTY. GENERAL NOTES 1 20151294205 CDA KF 2025 SHARP POINT DR., FT COLLINS, CO 80525 NEW VZW 525 SQ. FT. LEASE AREA NEW VZW 7789 SQ. FT. ACCESS/UTILITY EASEMENT NEW VZW 256 SQ. FT. UTILITY EASEMENT NEW LEASE AND EASEMENT COLOR LEGEND ACCESS UTILITY EASEMENT ANTENNAS DC POWER EXISTING EASEMENT FIBER HYBRID & COAX CABLES LEASE AREA NEW WORK_UTILITY EASEMENT PENETRATIONS RRHS WALL HATCH NEW WORK COLOR LEGEND SHEET TITLE PREPARED FOR: CHECKED BY: DRAWN BY: PROJECT NO: CONSULTING FIRM 3 INVERNESS DRIVE E STE 200 ENGLEWOOD, CO 80112 Construction - Project Management - Site Development 3131 S. VAUGHN WAY, #550 AURORA, CO 80014 FINAL FOR ZONING ONLY SHEET NUMBER PENETRATIONS RRH ANTENNAS FIBER POWER HYBRID & COAX CABLES REV DATE DESCRIPTION BY A 12/21/16 90% ZONING CDA 0 01/05/17 FINAL ZONING JMA 1 08/14/17 FINAL ZONING KM 2 02/14/18 PROJECT REDESIGN CGS N A C L E C ON N A C L E C O N S U L T I N I N G , I N C . P I N N A C . P I N E CO . PROJECT AREA CLIENT PROPERTY OWNER A&E CONSULTANT 2025 SHARP POINT DR LLC, NESTAC INVESTMENTS LLC, & MAVESA INVESTMENTS 2025, LLC 1401 RIVERSIDE AVE., FT COLLINS, CO 80524 CONTACT: DANIEL R. BERTH PHONE: (970)221-1965 EXT. 2 VERIZON WIRELESS 3131 S, VAUGHN WAY#550 AURORA, CO 80014 CONTACT: JENNIFER SCHNEIDER PHONE: (913) 344-2030 DEPART 3131 S. VAUGHN WAY (WEST); TURN LEFT AND MERGE ONTO CO-83 N, 0.1 MI; USE THE RIGHT 3 LANES TO TAKE THE INTERSTATE 225 N EXIT, 0.8 MI; MERGE ONTO I-225 S, 3.2 MI; USE THE RIGHT 2 LANES TO TAKE EXIT 1A FOR INTERSTATE 25 N TOWARD DENVER, 0.4 MI; MERGE ONTO I-25 N TOWARD FORT COLLINS, 51.6 MI; TAKE EXIT 265 FOR HARMONY RD, 0.2 MI; CONTINUE ON E. HARMONY RD. TAKE ZIEGLER RD, E DRAKE RD AND S TIMBERLINE RD TO MIDPOINT DR, 5.4 MI; DESTINATION WILL BE ON THE RIGHT. T-1 FTC PARKWOOD 2025 SHARP POINT DR., FT COLLINS, CO 80525 PROJECT INFORMATION FTC PARKWOOD 2025 SHARP POINT DR., FT COLLINS, CO 80525 20151294205 CDA KF REV DATE DESCRIPTION BY A 12/21/16 90% ZONING CDA 0 01/05/17 FINAL ZONING JMA 1 08/14/17 FINAL ZONING KM 2 02/14/18 PROJECT REDESIGN CGS SCOPE OF WORK · INSTALL OF (1) CO-LOCATABLE MONOPINE · INSTALL OF (3) SECTOR FRAMES · INSTALL (2) PROPOSED OVP'S · INSTALL (12) PROPOSED PANEL ANTENNAS · INSTALL (12) PROPOSED RRH'S · INSTALL (1) PROPOSED OUTDOOR POWER PLANT CABINET · INSTALL (1) PROPOSED RADIO EQUIPMENT CABINET · INSTALL (1) PROPOSED STAND-BY GENERATOR · INSTALL (1) PROPOSED EQUIPMENT CANOPY · INSTALL PROPOSED 35'x15' WOOD FENCE ENCLOSURE · INSTALL (2) PROPOSED TREES · INSTALL PROPOSED ELECTRIC SERVICE · INSTALL PROPOSED FIBER BACKHAUL · INSTALL PROPOSED 10'-0" x 16'-0" CONCRETE SLAB ZONING: I, DEVELOPING INDUSTRIAL PARCEL #: 08720105013 USE: UNMANNED COMMUNICATIONS PROPOSED LEASE AREA: 525 SQ. FT 40° 33' 36.65" N (NAD83) 105° 01' 39.97" W (NAD83) 4893' (NAVD88) NEW BUILD ZONING DRAWINGS SITE ACQUISITION PINNACLE CONSULTING, INC 3 INVERNESS DRIVE, EAST #200 ENGLEWOOD, CO 80112 CONTACT: BRENDAN THOMSON PHONE: (720) 460-2090 PINNACLE CONSULTING, INC. 3 INVERNESS DRIVE EAST #200 ENGLEWOOD, CO. 80112 CONTACT: KEVIN MILLER PHONE: (720) 296-6180 SITE PHOTO SHEET TITLE PREPARED FOR: CHECKED BY: DRAWN BY: PROJECT NO: CONSULTING FIRM 3 INVERNESS DRIVE E STE 200 ENGLEWOOD, CO 80112 Construction - Project Management - Site Development 3131 S. VAUGHN WAY, #550 AURORA, CO 80014 FINAL FOR ZONING ONLY SHEET NUMBER PENETRATIONS RRH ANTENNAS FIBER POWER HYBRID & COAX CABLES JURISDICTION: GOVERNING CODES: CITY OF FORT COLLINS 2012 IBC, 2012 IFC, 2012 IMC, 2012 IECC, 2014 NEC VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: (970) 646-1283 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU PHONE: (303) 901-3092 ALL BUILDING CODES LISTED ABOVE SHALL INCLUDE AMENDMENTS BY THE GOVERNING JURISDICTION SITE #: 397118 20151294205 PROJECT #: 20151294205 LEGAL DESCRIPTION: LOTS 13 & 14, PROSPECT INDUSTRIAL PARK, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO T-1 PROJECT INFORMATION GN-1 GENERAL NOTES LS-1 SITE SURVEY L-1 LANDSCAPE PLAN Z-1 SITE PLAN Z-2 ENLARGED SITE PLAN AND ANTENNA PLAN Z-3 ANTENNA PLAN Z-4 ELEVATIONS