HomeMy WebLinkAboutFTC UNIFY SC1, WTE (VERIZON) - PDP - PDP170022 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSITEM NO 2 of 3
MEETING
DATE
January 24, 2018
STAFF Kai Kleer
ADMINISTRATIVE HEARING OFFICER
Planning Services 281 N College Ave – PO Box 580 – Fort Collins, CO 80522-0580
fcgov.com/developmentreview/ 970.221.6750
STAFF REPORT
PROJECT: FTC Unify SC-1, PDP170022
APPLICANT: LRK Consulting
Ryan Sagar
1196 Grant Street
Suite 313
Denver, CO 80203
OWNER: Pickle Juice LLC
185 North College Avenue
Fort Collins, CO 80524
PROJECT DESCRIPTION:
This is a request for a Project Development Plan (PDP) to install wireless
telecommunication equipment concealed within an eight-foot eight-inch faux chimney on
an existing two-story building. The site is located at located at 185 North College Avenue
in the Downtown (D) zone district. The use is permitted in the zone district, subject to
approval by a Hearing Officer.
RECOMMENDATION: Staff recommends approval of the FTC Unify SC-1 Wireless
Telecommunication Equipment, PDP170022.
EXECUTIVE SUMMARY:
Staff finds the proposed FTC Unify SC-1 Project Development Plan complies with the
applicable requirements of the City of Fort Collins Land Use Code (LUC), more
specifically:
• The Project Development Plan complies with process located in Division 2.2 –
Common Development Review Procedures for Development Applications of
Article 2 – Administration.
• The Project Development Plan complies with relevant standards of Article 3 –
General Development Standards.
Staff Report – FTC Unify SC-1, PDP170022
Administrative Hearing 1-24-2018
Page 2
• The Project Development Plan complies with relevant standards located in Division
4.16 – Downtown (D) of Article 4 – Districts.
Staff Report – FTC Unify SC-1, PDP170022
Administrative Hearing 1-24-2018
Page 3
VICINITY MAP
Staff Report – FTC Unify SC-1, PDP170022
Administrative Hearing 1-24-2018
Page 4
COMMENTS:
1. Background
The surrounding zoning and land uses to each side of the project site are as follows:
Direction Zone District Existing Land Uses
North Downtown (D) Restaurant (Beau Jo’s)
South Downtown (D) Restaurant (Moe’s Original Bar B Que)
East Downtown (D)
Mixed-use dwellings, (Starbucks, Darvier
Jewelry, Butter Cream Cupcakery, Northern
Hotel Apartments)
West Downtown (D) Parking Garage (Civic Center Parking
Structure)
The site is located within Block 21 of the Original Town Site Plat on Lots 22 and 23. The
Plat was established and incorporated on February 3, 1873. Currently, the site contains
a two-story building built in 1999. The building comprises of two professional offices and
the Pueblo Viejo Mexican restaurant.
A zoning map is presented on the following page.
Staff Report – FTC Unify SC-1, PDP170022
Administrative Hearing 1-24-2018
Page 5
Map s: FTC Unify SC-1, Zoning Map
Staff Report – FTC Unify SC-1, PDP170022
Administrative Hearing 1-24-2018
Page 6
2. Compliance with Article 4 of the Land Use Code – Downtown zone district:
The project complies with all applicable Article 4 standards as follows:
A. Section 4.16(B)(2)(E) – Permitted Uses
Wireless telecommunication equipment is a permitted use in the Downtown
zone district, and within the Civic Center Subdistrict is subject to
Administrative (Type 1) review. The project proposes the installation of an
eight-foot eight-inch faux chimney that contains a single wireless
telecommunication antenna.
3. Compliance with Article 3 of the Land Use Code – General Development
Standards:
Article 3 includes additional standards specific to wireless telecommunication facilities
and equipment. Compliance with these standards is described in detail below:
A. Section 3.8.13 – Wireless Telecommunication
3.8.13(B) – Co-location
To reduce the impact of multiple carriers siting wireless telecommunication
equipment in more than one location, no facility or equipment owner or lessee
or employee thereof shall act to exclude or attempt to exclude any other
wireless telecommunication provider from using the same building, structure or
location.
The proposed plan contains notes indicating that owners and employees shall
cooperate to achieve future co-location efforts.
3.8.13(C)(3) – Wireless Telecommunication Equipment
Wireless telecommunication equipment must be of the same color as the
building or structure to which or on which such equipment is mounted.
The proposed project does not indicate that any wireless telecommunication
equipment will be visible from public view, however, notes have been added to
the proposed wall-mounted ladders so that they are painted to match the color
of the building.
Whenever a wireless telecommunication antenna is attached to a building roof,
the height of the antenna must not be more than fifteen (15) feet over the height
of the building.
Staff Report – FTC Unify SC-1, PDP170022
Administrative Hearing 1-24-2018
Page 7
The proposed height of the faux chimney is eight-feet eight-inch over the height
of the building. The proposal therefore does not exceed the maximum height
limit of 15 feet.
All wireless telecommunication equipment must be located as far from the edge
of the roof as possible. Even if the building is constructed at or above the
building height limitations contained in Section 3.8.17, the additional fifteen (15)
feet is permissible.
The proposed wireless antenna works on a line-of-sight basis and because of
this, the applicant proposes an eight-foot eight-inch chimney with a 10-foot
setback. The applicant asserts that the proposed location is the best way to
limit the impact of the concealment while also keeping in context with other
typical rooftop elements found throughout downtown.
Whenever wireless telecommunication equipment is mounted to the wall of a
building or structure, the equipment must be mounted in a configuration as flush
to the wall as technically possible and must not project above the wall on which
it is mounted. Such equipment must, to the maximum extent feasible, also
feature the smallest and most discreet components that the technology will
allow so as to have the least possible impact on the architectural character and
overall aesthetics of the building or structure. Roof and ground-mounted
wireless telecommunication equipment must be screened by parapet walls or
screen walls in a manner compatible with the building’s design, color and
material.
The proposed project conceals all associated wireless equipment accessory to
the antenna behind and below the existing parapet wall. The wireless antenna
is concealed within the faux chimney and features a stucco finish, chimney cap
and spark arrestor that are consistent with the buildings design.
3.8.13(C)(8) – Color
Telecommunication equipment must be painted to match as closely as possible
the color and texture of the wall, building or surrounding built environment.
Muted colors, earth tones and subdued colors must be used.
Notes for all items associated with this proposal and within public view have
been added to the plan to ensure that colors match the existing building.
4. Findings of Fact/Conclusion:
Staff Report – FTC Unify SC-1, PDP170022
Administrative Hearing 1-24-2018
Page 8
In evaluating the request for the FTC Unify SC-1, Wireless Telecommunication
Equipment Project Development Plan, staff makes the following findings of fact:
A. The FTC Unify SC-1 – Wireless Telecommunication Equipment Project
Development Plan complies with the process located in Division 2.2 –
Common Development Review Procedures for Development Applications
of Article 2 – Administration.
B. The FTC Unify SC-1 – Wireless Telecommunication Equipment Project
Development Plan complies with the applicable standards located in Article
3 – General Development Standards.
C. The FTC Unify SC-1 – Wireless Telecommunication Equipment Project
Development Plan complies with the applicable standards in Division 4.16,
Downtown District (D) of Article 4 – Districts.
RECOMMENDATION:
Staff recommends approval of the FTC Unify SC-1 – Wireless Telecommunication
Equipment Project Development Plan, PDP170022.
ATTACHMENTS:
1. Applicant’s Statement of Planning Objectives
2. FTC Unify SC-1 Plan Set
a. Title Sheet
b. Photosimulation Views
c. Site Plan
d. Enlarged Site Plan
e. Elevations
f. Line of Site Elevations
g. Faux Chimney Detail
h. Construction Details
LRK CONSULTING ON BEHALF OF VERIZON WIRELESS
June 26, 2017
Wireless-Telecommunications Equipment (Co-location) Review: Planning Objectives
FTC Unify SC1 located at 185 North College Ave, Parcel ID# 9711470003
My client, Verizon Wireless, wishes to submit an application for Wireless-Telecommunications
Equipment that will be located on top of a two-story building along College Avenue and in the heart of
Downtown Fort Collins. The installation of this new equipment will provide critical 4G-LTE voice and
data services to a location with increasingly higher pedestrian and vehicular traffic.
Specifically, my client proposes the installation of the following equipment:
• An Omni-directional antenna located inside a new square chimney structure. The total height of
the new chimney is 8’-8” above the existing roof height and shall be painted to match the color
of the main building.
• Remote Radio Heads (RRHs) and an Over-Voltage Protection Units (OVPs) placed behind the
building’s existing parapet wall. The RRHs are meant to limit line loss to the radio equipment,
while the OVP is installed to protect the rooftop equipment from electrical surges. This
equipment will not be visible from public view.
• Ladders to access the first and second floor rooftop of the building.
• A Fiber Vault located near the property line in the northwest corner of the property.
• Cabling from utility sources to rooftop equipment within new cable trays.
In accordance with the Communications and Technology section of the City Comprehensive Plan, this
new wireless equipment will provide citizens access to high-quality wireless service in a part of
downtown that faces significant capacity demands. Access to this improved service will continue to be
a critical component for community interactions as well as economic growth now that 4G-LTE has
become widely utilized.
Furthermore, this design carefully took into consideration and meets the standards as outlined in
Paragraph C, Subsections 3, 8, and 15 in Chapter 3.8.13 of the Municipal Code. Please let me know if
there is anything else I can provide you with to aid in the review of this project. I look forward to
working with your department as Verizon Wireless continues to invest in reliable, fast, and strong
wireless services in the City of Fort Collins.
Sincerely,
Senior Site Acquisition Consultant, LRK Consulting LLC
1196 Grant Street, Unit 313, Denver, CO 80203
mrsagar45@gmail.com
219-477-0099
FTC UNIFY SC 01
185 N COLLEGE AVENUE
FORT COLLINS, COLORADO 80524
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SHEET NUMBER:
SITE INFORMATION:
OF 8
SITE NAME:
FTC UNIFY SC 01
SITE ADDRESS:
185 N. COLLEGE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0125
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
F 08-09-17 KRC REV F
G 08-17-17 RPH REV G
H 09-13-17 RPH REV H
I 09-25-17 RPH REV I
J 10-04-17 RPH REV J
K 10-30-17 LCW REV K
L 12-15-17 GAC REV L
SMALL CELL NSB M 01-05-18 GAC REV M
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
DEPART 3131 S VAUGHN WAY, AURORA, CO 80014:
FROM SOUTH VAUGHN WAY, MERGE ONTO I-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W. KEEP
RIGHT AT THE FORK TO CONTINUE ON I-270 W. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS
FORT COLLINS. TAKE EXIT 289 TO MERGE ONTO CO-14 W/E MULBERRY STREET TOWARD FORT
COLLINS. TURN RIGHT ONTO RIVERSIDE AVENUE. CONTINUE ONTO JEFFERSON STREET. SHARP
LEFT ONTO N COLLEGE AVENUE. SITE WILL BE ON YOUR RIGHT.
FORT COLLINS, COLORADO
CLIENT PROJECT DATA
CODE ANALYSIS
IBC 2012 (W/ LOCAL AMMENDMENTS)
NEC 2014
NFPA-1 (2006)
U - UTILITY
IIB
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SHEET NUMBER:
SITE INFORMATION:
OF 8
SITE NAME:
FTC UNIFY SC 01
SITE ADDRESS:
185 N. COLLEGE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0125
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
F 08-09-17 KRC REV F
G 08-17-17 RPH REV G
H 09-13-17 RPH REV H
I 09-25-17 RPH REV I
J 10-04-17 RPH REV J
K 10-30-17 LCW REV K
L 12-15-17 GAC REV L
M 01-05-18 GAC REV M
PHOTOSIMULATION
VIEWS
PH-1
2
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING WEST)
N.T.S.
3
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTHWEST)
N.T.S.
2
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING WEST)
N.T.S.
4
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING NORTHWEST)
N.T.S.
UTIL UTIL UTIL UTIL UTIL
UTIL
UTIL
V
V
V
V
X
S
APN:
9711405021
AC
AC
AC
AC AC
AC
S
S
ET
GM
EM
EM
AC=
SD SD SD SD SD
SS SS
SS
GAS GAS GAS GAS
GAS GAS
UGE UGE
W
SS SS SS
F F F F
F F F
5'-0"
5'-0"
18'-7"
18'-10"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
3/32 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1 0 1 2 4 8 16 24 32 40
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SHEET NUMBER:
SITE INFORMATION:
V
V
V
V
AC
AC
AC
AC AC
GM AC
EM
EM
5'-0"
10'-0"
5'-0"
5'-0"
18'-7"
18'-10"
1/8 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
1
Z-3
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES,
LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR
OTHER PUBLIC AUTHORITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND
INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR
MUNICIPAL AUTHORITIES.
3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING,
OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF
BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID
DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY
FOR THE OVERALL INTENT OF THESE DRAWINGS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING
SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE
CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF
CONSTRUCTION OF THIS FACILITY.
5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL
MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT.
ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID
TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH
THE CONTRACT DOCUMENTS.
7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED
"BOUNDARY DETAIL" BY RLF CONSULTING, DATED 02/22/17.
8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN
STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE
PROPOSED.
9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO
HANDICAP ACCESS REQUIRED).
11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR
SANITARY SERVICE.
12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER.
13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF
ENGINEERING PRIOR TO INSTALLATION.
43'-9"
41'-0"
35'-8"
35'-8"
24'-8"
1/8 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SHEET NUMBER:
SITE INFORMATION:
OF 8
SITE NAME:
FTC UNIFY SC 01
SITE ADDRESS:
185 N. COLLEGE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0125
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
F 08-09-17 KRC REV F
G 08-17-17 RPH REV G
H 09-13-17 RPH REV H
I 09-25-17 RPH REV I
J 10-04-17 RPH REV J
K 10-30-17 LCW REV K
L 12-15-17 GAC REV L
M 01-05-18 GAC REV M
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
ELEVATIONS
Z-3
2
Z-3
PROPOSED ELEVATION
SCALE: 1/8"=1'-0"
TOP OF PROPOSED VERIZON ANTENNA
43'-9" AGL
GRADE
116'-0"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SHEET NUMBER:
SITE INFORMATION:
OF 8
SITE NAME:
FTC UNIFY SC 01
SITE ADDRESS:
185 N. COLLEGE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0125
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
F 08-09-17 KRC REV F
G 08-17-17 RPH REV G
H 09-13-17 RPH REV H
I 09-25-17 RPH REV I
J 10-04-17 RPH REV J
K 10-30-17 LCW REV K
L 12-15-17 GAC REV L
M 01-05-18 GAC REV M
LINE OF SITE
ELEVATIONS
Z-4
6
1
Z-4
LINE OF SIGHT ELEVATION
SCALE: 3/32"=1'-0"
PROPOSED LINE OF SIGHT FROM 5'8"
STANDING IN THE MIDDLE OF THE
SIDEWALK ON THE CORNER OF NORTH
COLLEGE AVE AND WALNUT ST
NOTE:
THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS A
VISUAL REPRESENTATION OF HOW THE SITE WOULD
APPEAR TO A 5' 8" PERSON STANDING ON THE SIDEWALK
ON THE CORNER OF NORTH COLLEGE AVENUE AND
WALNUT STREET.
NORTHERN
LANES OF N.
COLLEGE AVE
SOUTHERN
LANES OF N.
COLLEGE AVE
2
Z-4
PERSPECTIVE ELEVATION
N.T.S.
2'-2"
8'-4"
8'-8"
8'-4"
8'-8"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SHEET NUMBER:
SITE INFORMATION:
OF 8
SITE NAME:
FTC UNIFY SC 01
SITE ADDRESS:
185 N. COLLEGE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0125
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
F 08-09-17 KRC REV F
G 08-17-17 RPH REV G
H 09-13-17 RPH REV H
I 09-25-17 RPH REV I
J 10-04-17 RPH REV J
K 10-30-17 LCW REV K
L 12-15-17 GAC REV L
M 01-05-18 GAC REV M
FAUX CHIMNEY
DETAIL
Z-5
7
1
Z-5
FAUX CHIMNEY DETAIL
SCALE: 1"=1'-0"
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD (TO MATCH EXISTING STUCCO
FINISH OF BUILDING)
PROPOSED SPARK ARRESTOR
(FINAL DESIGN TBD)
(TO BE PAINTED TO MATCH
SECOND FLOOR OF BUILDING)
PROPOSED CHIMNEY CAP
(FINAL DESIGN TBD)
(TO BE PAINTED TO MATCH
SECOND FLOOR OF BUILDING)
PROPOSED ANTENNA WITHIN CHIMNEY
CONCEALMENT SHROUD
PROPOSED ANTENNA MOUNTING PIPE
WITHIN CHIMNEY CONCEALMENT SHROUD
TOP OF EXISTING PARAPET
25.8"
RRH WEIGHT: 56.8 LBS
ISOMETRIC VIEW
7.3"
12"
POWER
AISG PORT (-48VDC)
ALARM PORT
CPRI 2
CPRI 1
TOP VIEW BOTTOM VIEW
POWER
AISG PORT (-48VDC)
ALARM PORT
CPRI 2
CPRI 1
7.2"
12"
TOP VIEW BOTTOM VIEW
21.4"
ISOMETRIC VIEW
RRH WEIGHT: 53 LBS
9.96"
1.13"
9.16"
1'-0"
MICROLAB POWER
SPLITTER, D2-85FEP
(ORTHOGONAL)
2'-8"
1'-11"
1'-0"
2'-1"
1'-11"
1'-8"
CHARLES CUBE SMALL CELL CABINET
MODEL: RL11411AN1
CABINET WEIGHT:
82LBS. (AS SHIPPED)
2'-2"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SHEET NUMBER:
SITE INFORMATION:
OF 8
SITE NAME:
FTC UNIFY SC 01
SITE ADDRESS:
185 N. COLLEGE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0125
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
F 08-09-17 KRC REV F
G 08-17-17 RPH REV G
H 09-13-17 RPH REV H
I 09-25-17 RPH REV I
J 10-04-17 RPH REV J
K 10-30-17 LCW REV K
L 12-15-17 GAC REV L
M 01-05-18 GAC REV M
1
Z-5
AWS RRH DETAIL
N.T.S.
2
Z-5
PCS RRH DETAIL
N.T.S.
4
Z-5
PROPOSED SPLITTER DETAIL
N.T.S.
3
Z-5
CHARLES SMALL CELL CABINET
N.T.S.
CONSTRUCTION
DETAILS
Z-6
8
RF TRANSPARENT MATERIAL SPECIFICATIONS
FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES:
1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES.
2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING.
3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL.
4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX
USED IN THE STRUCTURAL SHAPE.
5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT
THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS,
GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION.
6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN
DRAWINGS.
7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS
FOLLOWS:
1/2" DIAMETER NUTS 8 FT-LBS TORQUE
5/8" DIAMETER NUTS 16 FT-LBS TORQUE
3/4" DIAMETER NUTS 24 FT-LBS TORQUE
FIBERGLASS PANEL NOTES: BY LARSON CAMOFLAGE, LLC
- FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN.
- PANELS TO BE MINIMUM 1/4" THICKNESS.
1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF
TRANSPARENT MATERIALS.
2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED
APPEARANCE.
3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT.
4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL
RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT.
5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS:
STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE
USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS.
6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE
ULTRAVIOLET PROTECTION.
7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN.
8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL
ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS.
9. CONTACT KEN PUEHL FOR ADDITIONAL INFORMATION AT 520-741-3115.
TOP OF EXISTING PARAPET
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD (TO MATCH EXISTING STUCCO
FINISH OF BUILDING)
3/32 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH CAP AND SPARK ARRESTOR
(SHROUD TO MATCH EXISTING STUCCO
FINISH OF THE BUILDING)
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH CAP AND SPARK ARRESTOR
(SHROUD TO MATCH EXISTING STUCCO
FINISH OF THE BUILDING)
PROPOSED LADDERS WITH CAGES, TURNAROUND
PLATFORMS AND SMALL LADDERS GOING FROM
PARAPET TO LOWER ROOF
(INCLUDE ANTENNA ACCESS SIGNAGE) (TYP)
(LADDERS TO BE PAINTED TO MATCH WALL
MOUNTED ON)
0'-0" AGL
PROPOSED PCS RRH MOUNTED
TO BACK OF PARAPET
5
PROPOSED AWS RRH MOUNTED
TO BACK OF PARAPET
TOP OF PARAPET
35'-8" AGL
TOP OF PARAPET
35'-8" AGL
TOP OF PARAPET
24'-8" AGL
GRADE
0'-0" AGL
PROPOSED VERIZON RAD CENTER
41'-0" AGL
1
Z-3
EXISTING ELEVATION
SCALE: 1/8"=1'-0"
GRADE
0'-0" AGL
EXISTING ROOF
LINE
EXISTING
ROOF LINE
EXISTING WOOD FENCE
EXISTING STORE FRONT EXISTING DOOR
PROPOSED VERIZON EQUIPMENT
CABINET MOUNTED TO BACK OF PARAPET
PROPOSED VERIZON ANTENNA MOUNTED TO
CUSTOM SLED MOUNT
PROPOSED LADDERS WITH CAGES, TURNAROUND
PLATFORMS AND SMALL LADDERS GOING FROM
PARAPET TO LOWER ROOF
(INCLUDE ANTENNA ACCESS SIGNAGE) (TYP)
(LADDERS TO BE PAINTED TO MATCH WALL
MOUNTED ON)
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH CAP AND SPARK ARRESTOR
(SHROUD TO MATCH EXISTING STUCCO FINISH
OF THE BUILDING)
14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015
REQUIREMENTS.
15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL.
16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES
PRIOR TO EXCAVATING.
17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT
AND CONTACT OWNERS REPRESENTATIVE.
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SHEET NUMBER:
SITE INFORMATION:
OF 8
SITE NAME:
FTC UNIFY SC 01
SITE ADDRESS:
185 N. COLLEGE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0125
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
F 08-09-17 KRC REV F
G 08-17-17 RPH REV G
H 09-13-17 RPH REV H
I 09-25-17 RPH REV I
J 10-04-17 RPH REV J
K 10-30-17 LCW REV K
L 12-15-17 GAC REV L
M 01-05-18 GAC REV M
ENLARGED
SITE PLAN
Z-2
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
1
Z-2
ENLARGED SITE PLAN
SCALE: 1/8"=1'-0"
NOTES:
1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION
MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING.
2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED
OTHERWISE.
3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY
AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO
INSTALLING ANY ANTENNAS.
PROPOSED VERIZON EQUIPMENT
CABINET MOUNTED ON PARAPET
N
4
PROPOSED 2'-0" x 3'-0"
FIBER VAULT
SECTOR A
VERIZON ANTENNA AZ= 0°
PROPOSED PCS RRH MOUNTED
BEHIND PARAPET WALL
COAX
DESIGNATION
CABLE TABLE
±70'
LENGTH
2
NO. TYPE
CONDUIT
3-CELL PLENUM
FIBER IN CONDUIT
N/A
FIBER RUN ±170' 1 2"
7/8" COAX
SIZE
MAXCELL INNERDUCT
PROPOSED AWS RRH MOUNTED
BEHIND PARAPET WALL
PROPOSED POWER ROUTED THROUGH
ROOF FROM EXISTING ELECTRICAL ROOM
PROPOSED FIBER RUN FROM VAULT
TO NEW EQUIPMENT CABINET
PROPOSED LADDERS WITH CAGES, TURNAROUND PLATFORMS
AND SMALL LADDERS GOING FROM PARAPET TO LOWER ROOF
(INCLUDE ANTENNA ACCESS SIGNAGE) (TYP)
(LADDERS TO BE PAINTED TO MATCH WALL MOUNTED ON)
PROPOSED COAX ROUTED ALONG
PARAPET TO EQUIPMENT LOCATION
PROPOSED VERIZON ANTENNA MOUNTED TO
CUSTOM SLED MOUNT
PROPOSED EME BARRIER FALLING WITHIN
FCC REQUIREMENT INCLUDING SIGNAGE AND
REQUIRED BARRICADES(DIMENSIONS TBD)
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH CAP AND SPARK ARRESTOR
(SHROUD TO MATCH EXISTING STUCCO
FINISH OF THE BUILDING)
PROPOSED FIBER ROUTED UP
SIDE OF BUILDING IN 2" CONDUIT
(PAINTED TO MATCH BUILDING)
OF 8
SITE NAME:
FTC UNIFY SC 01
SITE ADDRESS:
185 N. COLLEGE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0125
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
F 08-09-17 KRC REV F
G 08-17-17 RPH REV G
H 09-13-17 RPH REV H
I 09-25-17 RPH REV I
J 10-04-17 RPH REV J
K 10-30-17 LCW REV K
L 12-15-17 GAC REV L
M 01-05-18 GAC REV M
SITE PLAN
Z-1
1
Z-1
SITE PLAN
SCALE: 3/32"=1'-0"
PROPOSED 10' WIDE ACCESS
AND UTILITY EASEMENT
EXISTING
BUILDING
3
LAPORTE AVE
NORTH COLLEGE AVE
GENERAL NOTES:
1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY
DETAIL" BY RLF CONSULTING, DATED 06/03/17.
2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF.
THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED.
3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP
ACCESS REQUIRED).
5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY
SERVICE.
6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988).
7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE.
8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID
WASTE RECEPTACLES.
9. ANY WORK ASSOCIATED WITH THE ROOFING MEMBRANE SUCH AS ANCHORAGE,
CONDUIT PLACEMENT, ADDED ISOLATION PADS, ETC. MUST BE INSTALLED BY A ROOFER
THAT IS APPROVED BY THE MANUFACTURER OF THE INSTALLED ROOF MEMBRANE.
10. NOTIFICATION OF DATE AND TIME SHALL BE MADE TO THE APPROPRIATE WALMART
REPRESENTATIVES AGREED TO SUCH AS THE STORE MANAGER, CLIENT CONTACT AT
WALMART HEADQUARTERS OR CONSTRUCTION MANAGER.
11. ACCESS SHALL BE MADE VIA PROPER AREAS EITHER THROUGH THE ROOF HATCH OR
VIA THE JIB CRANE AREA.
12. FINAL WORK SHALL BE PROPERLY SEALED AND WATERTIGHT. ALL DEBRIS SHALL BE
REMOVED FROM THE ROOF AND PHOTOGRAPHIC RECORD OF FINAL CONDITION OF THE
ROOF SHALL BE SENT TO THE WALMART REPRESENTATIVE. NOTIFICATION OF
COMPLETION OF WORK SHALL BE DONE VIA THE AGREED UPON CHANNELS OF
COMMUNICATION.
13. RF SIGNAGE TO BE INSTALLED AT ANY/ALL ROOF ACCESS POINTS ON THE BUILDING.
LEGEND
W
SS
F
GAS GAS
OE
UT
X X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD
E
UE
OT
EV
D
O O
U/G
OHW
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
PROPOSED FIBER ROUTED UP
SIDE OF BUILDING IN 2" CONDUIT
(PAINTED TO MATCH BUILDING)
PROPOSED FIBER RUN TO NEW EQUIPMENT
CABINET MOUNT TO INSIDE OF PARAPET
PROPOSED
2'-0"x3'-0" FIBER
VAULT
PROPOSED LADDERS WITH CAGES, TURNAROUND PLATFORMS
AND SMALL LADDERS GOING FROM PARAPET TO LOWER ROOF
(INCLUDE ANTENNA ACCESS SIGNAGE) (TYP)
(LADDERS TO BE PAINTED TO MATCH WALL MOUNTED ON)
PROPOSED VERIZON ANTENNA MOUNTED TO
CUSTOM SLED MOUNT
PROPOSED EME BARRIER FALLING WITHIN
FCC REQUIREMENT INCLUDING SIGNAGE AND
REQUIRED BARRICADES(DIMENSIONS TBD)
PROPOSED EQUIPMENT MOUNTED
BEHIND PARAPET WALL
PROPOSED 5' x 10' EQUIPMENT
LEASE AREA BY VERIZON
(2) PROPOSED RRH'S MOUNTED
BEHIND PARAPET WALL
Z-2
1
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH CAP AND SPARK ARRESTOR
(SHROUD TO MATCH EXISTING STUCCO
FINISH OF THE BUILDING)
PROJECT DESCRIPTION
1. INSTALL NEW EQUIPMENT ON ROOFTOP BEHIND EXISTING PARAPET WALL.
2. INSTALL (1) NEW CUSTOM NON-PENETRATING SLED MOUNT ON ROOFTOP NOT VISIBLE FROM
STREET VIEW.
3. INSTALL (1) NEW FAUX CHIMNEY ATTACHED TO CUSTOM SLED MOUNT MOUNT WITH
CONCEALED ANTENNA INSIDE (PAINTED TO MATCH SECOND FLOOR OF BUILDING).
4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN ON STREET LEVEL.
5. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT.
6. INSTALL NEW COAX CABLES.
7. INSTALL NEW LADDER WITH CAGE FROM GROUND TO LOWER ROOF WITH SMALL LADDER
FROM TOP OF PARAPET TO LOWER ROOF(PAINTED TO MATCH WALL MOUNTED ON).
8. INSTALL NEW LADDER WITH CAGE FROM LOWER ROOF TO UPPER ROOF WITH TURNAROUND
AND SMALL LADDER DOWN FROM TOP OF PARAPET TO UPPER ROOF.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
JURISDICTION: CITY OF FT. COLLINS
ZONING: D-DOWNTOWN DISTRICT
APN: 97123-17-922
PARCEL SIZE: 14244 S.F.
ELEVATION: 4983' (NAVD 88)
SITE COORDINATES: N 40° 35' 19.43" (NAD 83)
W 105° 04' 38.78" (NAD 83)
STRUCTURE TYPE: BUILDING
STRUCTURE HEIGHT: 35'-8"± (TOP OF PARAPET)
ANTENNA RAD CENTER: 41'-0" AGL
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: JENNIFER THOMAS SCHNEIDER
10740 NALL AVE. STE 400
OVERLAND PARK, KS 66211
PH: 913-344-2030
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: 720-279-8973
Z-1
Z-3
Z-4
SITE PLAN
ELEVATIONS
LINE OF SITE ELEVATIONS
Z-2 ENLARGED SITE PLAN
PROPERTY OWNER
VERIZON WIRELESS REAL ESTATE
3131 S. VAUGHN WAY #550
OVERLAND PARK, KS 66211
CONTACT: JENNIFER THOMAS SCHNEIDER
PHONE: 913-344-2030
PICKLE JUICE, LLC
185 N COLLEGE AVE
FORT COLLINS, CO 80524
CONTACT: DAVID FRY
PHONE: 970-484-9555
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JASON SHELLEDY
PHONE: 970-646-1283
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
1196 GRANT ST. UNIT 313
DENVER, CO 80203
CONTACT: RYAN SAGAR
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: Ram.Nandiraju@verizonwireless.com
RF ENGINEER
LEGAL DESCRIPTION
LOT 22 AND 23, BLOCK 21
CITY OF FORT COLLINS, LARIMER COUNTY, COLORADO
Z-5 FAUX CHIMNEY DETAIL
PH-1 PHOTOSIMULATION VIEWS
Z-6 CONSTRUCTION DETAILS