Loading...
HomeMy WebLinkAboutFTC UNIFY SC1, WTE (VERIZON) - PDP - PDP170022 - SUBMITTAL DOCUMENTS - ROUND 2 - ARCHITECTURAL DETAILSFTC UNIFY SC 01 185 N COLLEGE AVENUE FORT COLLINS, COLORADO 80524 REVISION SCHEDULE REV A DATE 02-28-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SHEET NUMBER: SITE INFORMATION: OF 6 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0125 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-12-17 KRC REV B C 04-25-17 REV C D 05-11-17 REV D E 06-22-17 REV E KRC KRC KRC F 08-09-17 KRC REV F SMALL CELL NSB G 08-17-17 RPH REV G ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: FROM SOUTH VAUGHN WAY, MERGE ONTO I-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W. KEEP RIGHT AT THE FORK TO CONTINUE ON I-270 W. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FORT COLLINS. TAKE EXIT 289 TO MERGE ONTO CO-14 W/E MULBERRY STREET TOWARD FORT COLLINS. TURN RIGHT ONTO RIVERSIDE AVENUE. CONTINUE ONTO JEFFERSON STREET. SHARP LEFT ONTO N COLLEGE AVENUE. SITE WILL BE ON YOUR RIGHT. FORT COLLINS, COLORADO CLIENT PROJECT DATA CODE ANALYSIS IBC 2012 (W/ LOCAL AMMENDMENTS) NEC 2014 NFPA-1 (2006) U - UTILITY IIB UTIL UTIL UTIL UTIL UTIL UTIL UTIL V V V V X S APN: 9711405021 AC AC AC AC AC AC S S ET GM EM EM AC= SD SD SD SD SD SS SS SS GAS GAS GAS GAS GAS GAS UGE UGE W SS SS SS F F F F F F F 5'-0" 5'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 8 16 24 32 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 02-28-17 BY KRC PRELIMINARY DESCRIPTION V V V V AC AC AC AC AC GM AC EM EM 5'-0" 10'-0" 5'-0" 5'-0" 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 Z-3 GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 02/22/17. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 43'-9" 41'-9" 35'-8" 35'-8" 24'-8" 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 02-28-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SHEET NUMBER: SITE INFORMATION: OF 6 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0125 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-12-17 KRC REV B C 04-25-17 REV C D 05-11-17 REV D E 06-22-17 REV E KRC KRC KRC F 08-09-17 KRC REV F G 08-17-17 RPH REV G THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. ELEVATIONS Z-3 116'-0" REVISION SCHEDULE REV A DATE 02-28-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SHEET NUMBER: SITE INFORMATION: OF 6 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0125 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-12-17 KRC REV B C 04-25-17 REV C D 05-11-17 REV D E 06-22-17 REV E KRC KRC KRC F 08-09-17 KRC REV F G 08-17-17 RPH REV G LINE OF SITE ELEVATIONS Z-4 5 1 Z-4 LINE OF SIGHT ELEVATION SCALE: 3/32"=1'-0" PROPOSED LINE OF SIGHT FROM 5'8" STANDING IN THE MIDDLE OF THE SIDEWALK ON THE CORNER OF NORTH COLLEGE AVE AND WALNUT ST NOTE: THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS A VISUAL REPRESENTATION OF HOW THE SITE WOULD APPEAR TO A 5' 8" PERSON STANDING ON THE SIDEWALK ON THE CORNER OF NORTH COLLEGE AVENUE AND WALNUT STREET. NORTHERN LANES OF N. COLLEGE AVE 25.8" RRH WEIGHT: 56.8 LBS ISOMETRIC VIEW 7.3" 12" POWER AISG PORT (-48VDC) ALARM PORT CPRI 2 CPRI 1 TOP VIEW BOTTOM VIEW POWER AISG PORT (-48VDC) ALARM PORT CPRI 2 CPRI 1 7.2" 12" TOP VIEW BOTTOM VIEW 21.4" ISOMETRIC VIEW RRH WEIGHT: 53 LBS 9.96" 1.13" 9.16" 1'-0" MICROLAB POWER SPLITTER, D2-85FEP (ORTHOGONAL) 2'-8" 1'-11" 1'-0" 2'-1" 1'-11" 1'-8" CHARLES CUBE SMALL CELL CABINET MODEL: RL11411AN1 CABINET WEIGHT: 82LBS. (AS SHIPPED) 2'-2" REVISION SCHEDULE REV A DATE 02-28-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SHEET NUMBER: SITE INFORMATION: OF 6 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0125 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-12-17 KRC REV B C 04-25-17 REV C D 05-11-17 REV D E 06-22-17 REV E KRC KRC KRC F 08-09-17 KRC REV F G 08-17-17 RPH REV G 1 Z-5 AWS RRH DETAIL N.T.S. 2 Z-5 PCS RRH DETAIL N.T.S. 4 Z-5 PROPOSED SPLITTER DETAIL N.T.S. 3 Z-5 CHARLES SMALL CELL CABINET N.T.S. CONSTRUCTION DETAILS Z-5 6 SOUTHERN LANES OF N. COLLEGE AVE PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM SLED MOUNT (MOUNT TO BE PAINTED TO MATCH BUILDING COLOR: GLIDDEN PEACH PUFF, 80YR72/159) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM SLED MOUNT (MOUNT TO BE PAINTED TO MATCH BUILDING COLOR: GLIDDEN PEACH PUFF, 80YR72/159) 2 Z-4 PERSPECTIVE ELEVATION N.T.S. 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 Z-3 PROPOSED ELEVATION SCALE: 1/8"=1'-0" TOP OF PROPOSED VERIZON ANTENNA 43'-9" AGL GRADE 0'-0" AGL PROPOSED PCS RRH MOUNTED TO BACK OF PARAPET 4 PROPOSED AWS RRH MOUNTED TO BACK OF PARAPET TOP OF PARAPET 35'-8" AGL TOP OF PARAPET 35'-8" AGL TOP OF PARAPET 24'-8" AGL GRADE 0'-0" AGL PROPOSED VERIZON RAD CENTER 41'-9" AGL 1 Z-3 EXISTING ELEVATION SCALE: 1/8"=1'-0" GRADE 0'-0" AGL EXISTING ROOF LINE EXISTING ROOF LINE EXISTING WOOD FENCE EXISTING MAILBOX (TYP) EXISTING STORE FRONT EXISTING DOOR PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO BACK OF PARAPET PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM SLED MOUNT (MOUNT TO BE PAINTED TO MATCH BUILDING COLOR: GLIDDEN PEACH PUFF, 80YR72/159) PROPOSED LADDERS WITH CAGES, TURNAROUND PLATFORMS AND SMALL LADDERS GOING FROM PARAPET TO LOWER ROOF (INCLUDE ANTENNA ACCESS SIGNAGE) (TYP) 15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. REVISION SCHEDULE REV A DATE 02-28-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SHEET NUMBER: SITE INFORMATION: OF 6 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0125 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-12-17 KRC REV B C 04-25-17 REV C D 05-11-17 REV D E 06-22-17 REV E KRC KRC KRC F 08-09-17 KRC REV F G 08-17-17 RPH REV G ENLARGED SITE PLAN Z-2 THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-2 ENLARGED SITE PLAN SCALE: 1/8"=1'-0" NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. PROPOSED VERIZON EQUIPMENT CABINET MOUNTED ON PARAPET N 3 PROPOSED 2' x 3' FIBER VAULT SECTOR A VERIZON ANTENNA AZ= 0° EXISTING MAILBOX (USPS TYP) PROPOSED PCS RRH MOUNTED BEHIND PARAPET WALL COAX DESIGNATION CABLE TABLE ±70' LENGTH 2 NO. TYPE CONDUIT 3-CELL PLENUM FIBER IN CONDUIT N/A FIBER RUN ±170' 1 2" 7/8" COAX SIZE MAXCELL INNERDUCT PROPOSED AWS RRH MOUNTED BEHIND PARAPET WALL PROPOSED POWER ROUTED THROUGH ROOF FROM EXISTING ELECTRICAL ROOM PROPOSED FIBER RUN FROM VAULT TO NEW EQUIPMENT CABINET PROPOSED LADDERS WITH CAGES, TURNAROUND PLATFORMS AND SMALL LADDERS GOING FROM PARAPET TO LOWER ROOF (INCLUDE ANTENNA ACCESS SIGNAGE) (TYP) PROPOSED COAX ROUTED ALONG PARAPET TO EQUIPMENT LOCATION PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM SLED MOUNT (MOUNT TO BE PAINTED TO MATCH BUILDING COLOR: GLIDDEN PEACH PUFF, 80YR72/159) PROPOSED EME BARRIER FALLING WITHIN FCC REQUIREMENT INCLUDING SIGNAGE AND REQUIRED BARRICADES(DIMENSIONS TBD) PROPOSED CONCEALMENT SHROUD (SHROUD TO BE PAINTED TO MATCH BUILDING COLOR: GLIDDEN PEACH PUFF, 80YR72/159) DRAWING TITLE: DRAWING SHEET: SHEET NUMBER: SITE INFORMATION: OF 6 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0125 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-12-17 KRC REV B C 04-25-17 REV C D 05-11-17 REV D E 06-22-17 REV E KRC KRC KRC F 08-09-17 KRC REV F G 08-17-17 RPH REV G SITE PLAN Z-1 1 Z-1 SITE PLAN SCALE: 3/32"=1'-0" PROPOSED 10' WIDE ACCESS AND UTILITY EASEMENT EXISTING BUILDING 2 LAPORTE AVE NORTH COLLEGE AVE EXISTING MAILBOX GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 06/03/17. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. 9. ANY WORK ASSOCIATED WITH THE ROOFING MEMBRANE SUCH AS ANCHORAGE, CONDUIT PLACEMENT, ADDED ISOLATION PADS, ETC. MUST BE INSTALLED BY A ROOFER THAT IS APPROVED BY THE MANUFACTURER OF THE INSTALLED ROOF MEMBRANE. 10. NOTIFICATION OF DATE AND TIME SHALL BE MADE TO THE APPROPRIATE WALMART REPRESENTATIVES AGREED TO SUCH AS THE STORE MANAGER, CLIENT CONTACT AT WALMART HEADQUARTERS OR CONSTRUCTION MANAGER. 11. ACCESS SHALL BE MADE VIA PROPER AREAS EITHER THROUGH THE ROOF HATCH OR VIA THE JIB CRANE AREA. 12. FINAL WORK SHALL BE PROPERLY SEALED AND WATERTIGHT. ALL DEBRIS SHALL BE REMOVED FROM THE ROOF AND PHOTOGRAPHIC RECORD OF FINAL CONDITION OF THE ROOF SHALL BE SENT TO THE WALMART REPRESENTATIVE. NOTIFICATION OF COMPLETION OF WORK SHALL BE DONE VIA THE AGREED UPON CHANNELS OF COMMUNICATION. 13. RF SIGNAGE TO BE INSTALLED AT ANY/ALL ROOF ACCESS POINTS ON THE BUILDING. LEGEND W SS F GAS GAS OE UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD E UE OT EV D O O U/G OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING PROPOSED FIBER ROUTED UP SIDE OF BUILDING IN 2" CONDUIT PROPOSED FIBER RUN TO NEW EQUIPMENT CABINET MOUNT TO INSIDE OF PARAPET PROPOSED 2'x3' FIBER VAULT PROPOSED LADDERS WITH CAGES, TURNAROUND PLATFORMS AND SMALL LADDERS GOING FROM PARAPET TO LOWER ROOF (INCLUDE ANTENNA ACCESS SIGNAGE) (TYP) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM SLED MOUNT (MOUNT TO BE PAINTED TO MATCH BUILDING COLOR: GLIDDEN PEACH PUFF, 80YR72/159) PROPOSED EME BARRIER FALLING WITHIN FCC REQUIREMENT INCLUDING SIGNAGE AND REQUIRED BARRICADES(DIMENSIONS TBD) PROPOSED EQUIPMENT MOUNTED BEHIND PARAPET WALL PROPOSED 5' x 10' EQUIPMENT LEASE AREA BY VERIZON (2) PROPOSED RRH'S MOUNTED BEHIND PARAPET WALL Z-2 1 BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET PROJECT DESCRIPTION 1. INSTALL NEW EQUIPMENT ON ROOFTOP BEHIND EXISTING PARAPET WALL. 2. INSTALL (1) NEW NON-PENETRATING TRIPOD MOUNT ON ROOFTOP NOT VISIBLE FROM STREET VIEW. 3. INSTALL (1) NEW CHIMNEY ATTACHED TO TRIPOD MOUNT WITH CONCEALED ANTENNA INSIDE (PAINTED PEACH PUFF OR MOST SIMILAR AVAILABLE COLOR TO MATCH EXISTING BUILDING). 4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN ON STREET LEVEL. 5. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT. 6. INSTALL NEW COAX CABLES. 7. INSTALL NEW LADDER WITH CAGE FROM GROUND TO LOWER ROOF WITH SMALL LADDER FROM TOP OF PARAPET TO LOWER ROOF. 8. INSTALL NEW LADDER WITH CAGE FROM LOWER ROOF TO UPPER ROOF WITH TURNAROUND AND SMALL LADDER DOWN FROM TOP OF PARAPET TO UPPER ROOF. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: D-DOWNTOWN DISTRICT APN: 97123-17-922 PARCEL SIZE: 14244 S.F. ELEVATION: 4983' (NAVD 88) SITE COORDINATES: N 40° 35' 19.43" (NAD 83) W 105° 04' 38.78" (NAD 83) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 35'-8"± (TOP OF PARAPET) ANTENNA RAD CENTER: 40'-4" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: JENNIFER THOMAS SCHNEIDER 10740 NALL AVE. STE 400 OVERLAND PARK, KS 66211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720-279-8973 Z-1 Z-3 Z-4 SITE PLAN ELEVATIONS LINE OF SITE ELEVATIONS Z-2 ENLARGED SITE PLAN PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 3131 S. VAUGHN WAY #550 OVERLAND PARK, KS 66211 CONTACT: JENNIFER THOMAS SCHNEIDER PHONE: 913-344-2030 PICKLE JUICE, LLC 185 N COLLEGE AVE FORT COLLINS, CO 80524 CONTACT: DAVID FRY PHONE: 970-484-9555 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: Ram.Nandiraju@verizonwireless.com RF ENGINEER LEGAL DESCRIPTION CONDOMINIUM UNIT 3, 185 NORTH COLLEGE CONDOMINIUMS, TO THE CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO ACCORDING TO THE CONDOMINIUM MAP RECORDED FEBRUARY 19, 2002 AT RECEPTION NO. 2002018370, AND IN ACCORDANCE WITH AND SUBJECT TO THE CONDOMINIUM DECLARATION RECORDED FEBRUARY 19, 2002 AT RECEPTION NO. 2002018371. Z-5 CONSTRUCTION DETAILS