Loading...
HomeMy WebLinkAboutFTC UNIFY SC1, WTE (VERIZON) - FDP - FDP180013 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSFTC UNIFY SC 01 185 N. COLLEGE AVE FORT COLLINS, CO 80524 SMALL CELL NSB CONSTRUCTION DRAWINGS PROJECT AREA SITE DIRECTIONS FROM 3131 SOUTH VAUGHN WAY: MERGE ONTO I-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W, KEEP RIGHT AT THE FORK TO CONTINUE ON I-270 W, TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FT. COLLINS, TAKE EXIT 289 TO MERGE ONTO CO-14 W/E MULBERRY STREET TOWARD FORT COLLINS, TURN RIGHT ONTO RIVERSIDE AVE, CONTINUE ONTO JEFFERSON STREET , SHARP LEFT ONTO N COLLEGE AVENUE, SITE WILL BE ON YOUR RIGHT. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER PICKLE JUICE, LLC 185 N. COLLEGE AVE FORT COLLINS, CO 80524 CONTACT: DAVID FRY PHONE: 970-484-9655 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2012 (W/ LOCAL AMENDMENTS) NEC 2014 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 ENLARGED SITE PLAN C-1 EQUIPMENT PLAN PROJECT DESCRIPTION 1. INSTALL NEW EQUIPMENT ON ROOFTOP BEHIND EXISTING PARAPET WALL. 2. INSTALL (1) NEW CUSTOM NON-PENETRATING SLED MOUNT ON ROOFTOP NOT VISIBLE FROM STREET VIEW. 3. INSTALL (1) NEW FAUX CHIMNEY ATTACHED TO CUSTOM SLED MOUNT MOUNT WITH CONCEALED ANTENNA INSIDE (PAINTED TO MATCH SECOND FLOOR OF BUILDING). 4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN ON STREET LEVEL. 5. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT. 6. INSTALL NEW COAX CABLES 7. INSTALL NEW LADDER WITH CAGE FROM GROUND TO LOWER ROOF WITH SMALL LADDER FROM TOP OF PARAPET TO LOWER ROOF(PAINTED TO MATCH WALL MOUNTED ON). 8. INSTALL NEW LADDER WITH CAGE FROM LOWER ROOF TO UPPER ROOF WITH TURNAROUND GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 06/03/17. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES.ANY WORK ASSOCIATED WITH THE ROOFING MEMBRANE SUCH AS ANCHORAGE, CONDUIT PLACEMENT, ADDED ISOLATION PADS, ETC. MUST BE INSTALLED BY A ROOFER THAT IS APPROVED BY THE MANUFACTURER OF THE INSTALLED ROOF MEMBRANE. 9. ACCESS SHALL BE MADE VIA PROPER AREAS EITHER THROUGH THE ROOF HATCH. 10. FINAL WORK SHALL BE PROPERLY SEALED AND WATERTIGHT. 11. RF SIGNAGE TO BE INSTALLED AT ANY/ALL ROOF ACCESS POINTS ON THE BUILDING. GENERAL NOTES GN-1 LEGEND W W SS SS SS F F F GAS GAS GAS GAS GAS OE OE UT UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD SD SD SD E E E REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A UTIL UTIL V V V V S AC AC AC AC AC AC S S D ET GM EM EM AC= SD SD GAS GAS UGE SS F F E E E E REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL AC V AC AC AC= F F F E E E 10'-0" 5'-0" 10'-0" 10'-0" REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N F F F E E E 56'-10" 10'-0" 10'-0" REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S UTIL REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N X X X X X X X X X X X X X X X X 35'-8" 24'-8" X X X X X X X X X X X X X X X X 35'-8" 41'-0" 44'-4" 24'-8" REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A 8'-4" 8'-8" 2'-2" 8'-4" 8'-8" REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S CHARLES CUBE SMALL CELL CABINET MODEL: RL11411AN1 CABINET WEIGHT: 82LBS. (AS SHIPPED) 2'-8" 1'-11" 2'-1" 1'-0" 2'-1" 1'-10" U.L. SYSTEM NO. CAJI150 METAL PIPE/CONDUIT THROUGH CONCRETE FLOOR OR WALL F RATING = 3-HR T RATING = 0-HR TOP VIEW A A SECTION A-A MIN. 1/2" DEPTH CROWN OF HILTI FS601 SEALANT AT POINT OF CONTACT PROPOSED EMT CONDUIT REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O 2'-6" 1'-6" 4" 6" MIN. (TYP) 4" MIN. TO SECONDARY ELECTRIC 12" MIN. TO PRIMARY ELECTRIC NOTES: 1. CONTRACTOR TO ORDER HANDHOLE BOX WITH THE CORRECT NUMBER AND SIZE OF KNOCKOUTS NEEDED. 2. VERIFY DIMENSIONS OF UNIT. 24" 26" 30" BOX COVER 37 5/8" 35 3/8" REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I 2'-4" 1'-8" 3'-6" MIN 7" MIN 6'-0" TYP 1'-7" 7'-0" MIN 8'-0" MAX REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F 10'-0 1/2" 2'-5 3/4" 1'-6 1/2" 1'-5 1/2" 3'-0 3/4" 8'-10 1/4" 9'-0 1/2" 5'-0 1/4" 1'-0 3/4" 10 1/2" 2'-0" REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P 10'-0" 10'-0 1/2" 2'-5" 1'-6" 1'-6" 1'-2" 1'-6 1/2" 6'- 11 1/2" 8'-5 3/4" 10'-0" 10'-0 1/2" 1'-5 1/2" 2'-5" 1'-9" 3'-8" 11" 11" 1'-9" 2'-0" 1'-5 1/2" 1'-2" 7 13/16" 1'-4 1/2" REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O 1 1/4" 1 1/4" 1 1/4" " 3" 3" 1 3/4" TYP 4 3/4" TYP 1 1/2" TYP 1 1/4" 1 1/4" 4 3/4" 1 1/4" TYP 1 3/4" 1 15/16" 2 11/16" 2 1/4" 1 13/16" 2 1/4" 1 7/8" 1 1/8" PROPOSED 1/2" A325 BOLT - FROM TOP PLATE TO TOP ANGLES (TYP OF 4) PROPOSED 1/4" THICK TOP PLATE NOT SHOWN FOR CLARITY PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED 1/2" A325 THRU BOLT (TYP OF 8) PROPOSED L3x3x1/4 TOP ANGLE - THRU BOLT TO FRP TUBE (TYP OF 4) PROPOSED 1/2" A325 BOLT - FROM TOP PLATE TO TOP ANGLES PROPOSED FRP 3"x3"x1/4" TUBE PROPOSED 1/2" A325 THRU BOLT PROPOSED L3x3x1/4 TOP ANGLE - THRU BOLT TO FRP TUBE PROPOSED 1/4" THICK TOP PLATE BOLTED TO TOP ANGLES REVISION SCHEDULE REV 0 DATE 2" 1" 1" 2" 1'-1 7/8" 1' 4 3/8" 6 15/16" 1 1/4" 1 3/8" 1'-9" 1'-9" PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED 1/2" A325 THRU BOLT (TYP OF 16) PROPOSED L6x4x5/16 INTERIOR ANGLE WELDMENT. THRU BOLT TO FRP TUBE (TYP OF 4) REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A 9'-0 1/2" 6'-8 1/2" 10'-0 1/2" 10'-0" 10'-0" 3'-0" (MAX) REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F 25.8" RRH WEIGHT: 56.8 LBS ISOMETRIC VIEW 7.3" 12" TOP VIEW BOTTOM VIEW 7.2" 12" TOP VIEW BOTTOM VIEW 21.4" ISOMETRIC VIEW RRH WEIGHT: 53 LBS REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A PROPOSED UNISTRUT PROPOSED RRH'S (2) #2 GREEN THHN GROUND WIRE TO GROUND ROD AT GRADE (FOLLOW FIBER ROUTE TO GRADE) 5/8"Ø x 10' LONG COPPER GROUND ROD (BURY 36" BFG) PROPOSED EQUIPMENT GROUND BAR #6 GREEN THHN GROUND WIRE PROPOSED COAX GROUND LEAD FROM MOUNT STEEL TO GROUND BAR PROPOSED ANTENNA GROUND BAR PROPOSED COAX GROUNDING KIT #6 SOLID TINNED GROUND WIRE PROPOSED ANTENNA PROPOSED CUSTOM MOUNT PROPOSED EQUIPMENT CABINET REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) TYPE NC TYPE GT TYPE GL LUG TYPE HA TYPE GR TYPE VS TYPE HS TYPE SS TYPE XA TYPE PT WEATHERPROOFING KIT (TYP) RX1/RX2 TX1/TX2 STANDARD GROUND KIT (TYP) #6 AWG STRANDED Cu WIRE WITH GREEN, 600V, THWN INSULATION GROUND BAR, MOUNTED NEAR/BELOW ANTENNA #2 AWG Cu STRANDED WIRE WITH GREEN, 600V, THWN INSULATION BONDED TO GROUND BAR AT GRADE JUMPER REQUIRED ONLY FOR EASE OF CONNECTION AND STRESS REDUCTION ON ANTENNA CONNECTORS (TYP) CONNECTOR WATERPROOFING KIT (TYP) TO ANTENNA NOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO CRGB (2) (3) (5) (4) (1) GALVANIZED STEEL GROUND BAR, BY ELECTRIC MOTION COMPANY (SEE SCHEDULE BELOW). INSULATORS, BY HARGER CAT. #5263-A5. 5/8 " LOCKWASHERS, STAINLESS STEEL. WALL MOUNTING BRACKET, HARGER CAT. #WBKT-2. 5/8-11x3" H.H.C.S. BOLTS, STAINLESS STEEL. LEGEND "GALV STEEL" STEEL STAMPED ON EITHER END CADWELD AT TWO LOCATIONS REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 CABLE TO ANTENNA CABLE GROUNDING CLAMP KIT #6 AWG GREEN INSULATED COPPER GROUNDING CONDUCTOR CABLE TO EQUIPMENT 3M SCOTCH SUPER 33+ VINYL ELECTRICAL TAPE (OR APPROVED EQUAL) PROPOSED COAX VAPOR WRAP SEALANT COAX TO JUMPER CONNECTION PROPOSED JUMPER GROUNDING DETAILS G-2 23 1 G-2 TYPICAL CABLE GROUNDING SCALE: N.T.S. 2 G-2 WEATHERPROOFING DETAIL SCALE: N.T.S. 3 G-2 TYPICAL CADWELD TYPE CONNECTIONS SCALE: N.T.S. 4 G-2 ANTENNA GROUND BAR CONNECTIONS SCALE: N.T.S. 5 G-2 GROUND BAR DETAIL SCALE: N.T.S. 03/30/18 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 GROUNDING PLAN G-1 22 1 G-1 ANTENNA/RRH GROUNDING DETAIL SCALE: 3/4"=1'-0" 03/30/18 L E N G I N E E R 52731 NOTES: 1. ELECTRICAL SERVICE SHALL BE 30A. 2. SERVICE SHALL BE INSTALLED WITH A LEVER TYPE DISCONNECT. 3. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT, REFER TO VENDOR PRINTS PROVIDED BY EQUIPMENT CABINET MANUFACTURER. 4. METER BY FT. COLLINS L&P. SEE INTERNAL WIRING DIAGRAM PROVIDED BY MANUFACTURER FOR DETAILS. 5. VERIZON TO PULL 19.25A FROM ELECTRICAL SERVICE. PROPOSED 2" EMT CONDUIT (3)-#1 AWG CU CONDUCTORS, (1)-#8 GROUND (100' RUN) PROPOSED 100A METER PROPOSED 100A LEVER-TYPE SERVICE DISCONNECT FAULT: 7,017A (L-L) PROPOSED (3) - #1 AWG CU CONDUCTORS IN 2" PVC CONDUIT (90' RUN) EXISTING 300KVA 120/208V 3 TRANSFORMER. FAULT: 37,010 A PROPOSED 100A LEVER-TYPE DISCONNECT FAULT: 3,645A PROPOSED 100A ELECTRICAL PANEL EXISTING 120/208V 3 PHASE TRANSFORMER FAULT: 31,010 PROPOSED 100A METER PROPOSED 2" EMT CONDUIT (3) #1 AWG CU CONDUCTOR (90' RUN) PROPOSED 2" EMT CONDUIT (3) - #1 AWG CU CONDUCTORS (1) - #8 AWG CU GROUND PROPOSED 100A LEVER-TYPE DISCONNECT PROPOSED 100A LEVER-TYPE DISCONNECT PROPOSED VZW CABINET PROPOSED 100A, 120/208V, 1Ø, 3W PANEL SCHEDULE LOAD SERVED RECTIFIER #1 SPARE GFCI VOLT AMPS VOLT AMPERES (WATTS) L1 L2 500 20A 25A TRIP CKT # PHASE CKT # TRIP L1 VOLT AMPERES L2 VOLT AMPERES 500 180 L1 L2 680 500 RECTIFIER #2 RECTIFIER #3 VOLT AMPERES (WATTS) LOAD SERVED 1 3 5 7 A B A B 2 4 6 8 25A 25A 500 500 500 500 L1 AMPS L2 AMPS MAX AMPS MAX AMPS x125% X 110% FOR MAIN 1680 1500 12.5 14 14 17.5 19.25 1000 1000 VOLT AMPS PROPOSED 100A PANEL FAULT: 3559 A ONE-LINE DIAGRAM & PANEL SCHEDULE E-1 21 1 E-1 ONE-LINE DIAGRAM SCALE: N.T.S. 2 E-1 ONE-LINE ELEVATION SCALE: N.T.S. PROPOSED 2" EMT CONDUIT (3)-#1 AWG CU CONDUCTORS, (1)-#8 GROUND (5' RUN) PROPOSED 2" EMT CONDUIT (3) - #1 AWG CU CONDUCTORS (1) - #8 AWG CU GROUND 03/30/18 D P R O F E S S I O N A L E N G I N E E R 52731 OVP & REMOTE RADIO HEAD DETAILS A-2 20 1 A-2 AWS RRH DETAIL N.T.S. POWER (-48VDC) ALARM PORT AISG PORT CPRI 2 CPRI 1 ALARM PORT AISG PORT CPRI 2 CPRI 1 POWER (-48VDC) 2 A-2 PCS RRH DETAIL N.T.S. 03/30/18 E S S I O N A L E N G I N E E R 52731 NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. ANTENNA & CABLE SCHEDULE SECTOR AZIMUTH MOUNTING HEIGHT TECHNOLOGY ANTENNA SPECIFICATIONS MECHANICAL DOWNTILT ELECTRICAL DOWNTILT CABLE SIZE CABLE LENGTH A N/A 41'-0" AWS/PCS SMALL CELL 48.0"(L) X 14.6"(W) (4.65 FT³) 50 LBS 0° 0° (4) 7/8" COAX 70 FT. PROPOSED AWS RRH MOUNTED TO BACKSIDE OF PARAPET (SEE DETAIL 1/A-2) PROPOSED PCS RRH MOUNTED TO BACKSIDE OF PARAPET WALL (SEE DETAIL 2/A-2) PROPOSED 3'-0" WIDE TRAFFIC MAT FROM ROOF ACCESS POINT TO PROPOSED EQUIPMENT PLUMBING DIAGRAM TBD ACCORDING TO THE STRUCTURAL ANALYSIS BY AERO SOLUTIONS, LLC DATED 01/08/18, THE PROPOSED MOUNT REQUIRES A MINIMUM OF 120 LBS OF BALLAST PER SIDE, 480 LBS TOTAL ANTENNA SCHEDULE, MOUNTING PLAN & PLUMBING DIAGRAM A-1 19 N PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO BACKSIDE OF PARAPET WALL (SEE DETAIL 1/C-6) PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH CAP AND SPARK ARRESTOR(SHROUD TO MATCH EXISTING STUCCO FINISH OF BUILDING) (SEE SHEET C-5 FOR MORE DETAIL) PROPOSED EME SIGNAGE TO BE INSTALLED ON ANTENNA MOUNT (SEE SHEET C-2 FOR MORE DETAIL) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM NON-PENETRATING SLED MOUNT WITH CONCEALMENT SHROUD(PAINT TO MATCH) (SEE DETAIL 2/A-1) PROPOSED COAX ROUTED ON SLEEPERS FROM EQUIPMENT TO ANTENNA LOCATION (SEE DETAIL 2/C-6) 1 A-1 PROPOSED ANTENNA LAYOUT SCALE: 3/8"=1'-0" 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 6 8 10 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED ANTENNA MOUNT PROPOSED 4'-0" LONG 3.0" STD MOUNTING PIPE PROPOSED OMNI ANTENNA PROPOSED CUSTOM NON-PENETRATING MOUNT (SEE SHEETS ST-1 THROUGH ST-5 FOR MORE DETAIL) 2 A-1 ANTENNA MOUNTING DETAIL SCALE: 3/4"=1'-0" 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 PROPOSED 100A LEVER-TYPE DISCONNECT MOUNTED TO BACKSIDE OF PARAPET WALL PROPOSED 100A POWER PANEL MOUNTED TO BACKSIDE OF PARAPET WALL 03/30/18 L E N G I N E E R 52731 STRUCTURAL NOTES: 1. DESIGN INFORMATION AND GENERAL REQUIREMENTS 1.1 CODES a. DESIGN CONFORMS TO 2015 INTERNATIONAL BUILDING CODE. b. ASCE 7-10 MIN. DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES. c. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, ANSI/AISC 360-10. 1.2 MISCELLANEOUS a. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. 2. STRUCTURAL STEEL 2.1 MATERIALS a. STRUCTURAL STEEL. . . . . . . . ASTM A992 CHANNEL . . . . . . . . . . . . . . . . . . .ASTM A36 ANGLES, PLATE & MISC. . . . . . ASTM A36 RECTANGULAR HSS . . . . . . . . . ASTM A500, GRADE B, Fy=46 ksi ROUND HSS . . . . . . . . . . . . . . . . ASTM A500, GRADE B, Fy=42 ksi PIPES . . . . . . . . . . . . . . . . . . . . . ASTM A53, GRADE B b. BOLTS . . . . . . . . . . . . . . . . . . . . ASTM A325 U.N.O. c. WELDING ELECTRODES . . . . . . . . AWS A5.1 (E70XX) d. STEEL CONSTRUCTION SHALL CONFORM TO "SPECIFICATION FOR STRUCTURAL STEEL FOR BUILDINGS - 14TH EDITION". e. WELDING SHALL CONFORM TO AWS D1.1 "STRUCTURAL WELDING CODE". f. THE FABRICATOR SHALL FURNISH CHECKED SHOP AND ERECTION DRAWINGS TO THE ENGINEER, AND OBTAIN APPROVAL PRIOR TO FABRICATING ANY STRUCTURAL STEEL. SHOP DRAWINGS SHALL CONFORM TO AISC "DETAILING FOR STEEL CONSTRUCTION". 2.2 CONNECTIONS a. SHOP CONNECTIONS MAY BE BOLTED OR WELDED. b. FIELD CONNECTIONS SHALL BE BOLTED WITH A325-N BOLTS, (INSTALLED SNUG TIGHT) UNLESS OTHERWISE SPECIFIED OR IF WELDED CONNECTIONS ARE NOTED ON DRAWINGS. c. FIELD CONNECTIONS SHALL BE MADE WITH HIGH TENSILE BOLTS AND HARDENED WASHERS EXCEPT AS INDICATED ON THE DESIGN DRAWINGS. d. CONNECTIONS NOT SHOWN ON DRAWINGS SHALL BE DESIGNED BY THE STEEL FABRICATOR. CONNECTIONS SHALL BE DESIGNED IN ACCORDANCE WITH AISC "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" AND AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". e. DO NOT FIELD CUT OR ALTER STRUCTURAL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL OF ENGINEER. 2.3 FINISHES a. STRUCTURAL STEEL SHALL BE HOT DIP GALVANIZED AFTER FABRICATION PER ASTM A123 b. ALL STEEL SHALL BE CLEANED OF RUST, LOOSE MILL SCALE AND OTHER FOREIGN MATERIALS AND BE HOT DIPPED GALVANIZED OR STAINLESS STEEL IF OTHERWISE INDICATED ON PLAN. c. FIELD FABRICATIONS SHALL BE TREATED WITH ZRC COLD GALVANIZING COMPOUND OR EQUAL PRIOR TO ASSEMBLY. d. BOLTS AND NUTS SHALL BE HOT DIP GALVANIZED PER ASTM A153. 3.1 MATERIALS a. USE STRONGWELL EXTREN FIBERGLASS STRUCTURES SERIES 625 TUBES AND ANGLES UNLESS OTHERWISE NOTED. b. FRP PANELS ARE TO BE UV RESISTANT FOR EXTERIOR EXPOSURE AND MUST BE RF TRANSPARENT TO ALLOW UNIMPEDED ANTENNA/MICROWAVE DISH SIGNAL PROPAGATION. c. ATTACH PANEL ACCORDING TO MANUFACTURERS RECOMMENDATIONS. d. FRP MATERIALS ARE TO BE CONSTRUCTED TO MEET ALL OF THE MANUFACTURERS REQUIREMENTS. e. DO NOT ALTER STRUCTURAL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL OF ENGINEER OF RECORD. f. FRP MEMBERS MAY BE SAWED, DRILLED, ROUTED, AND TURNED ON A LATHE OR OTHER MACHINE TOOL. PUNCHING SHALL NOT BE PERMITTED. CARBIDE OR DIAMOND TIPPED TOOLS ARE RECOMMENDED. g. FRP MEMBERS MAY BE FASTENED MECHANICALLY USING SCREWS, BOLTS, OR RIVETS. FIBERBOLT FIBERGLASS STUDS AND HEX HEADS SHOULD BE USED ONLY WHERE SPECIFICALLY SHOWN IN THE DESIGN DRAWINGS. h. FRP MEMBERS MAY BE CONNECTED WITH ADHESIVE ONLY IF USED IN CONJUNCTION WITH THE SPECIFIED MECHANICAL FASTENERS. 3. FIBER REINFORCED POLYMER STRUCTURAL NOTES ST-5 18 03/30/18 O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 PROPOSED L3x3x1/4 BALLAST TRAY ANGLE (TYP) BACKGOUGE (TYP) 3/16" PROPOSED BOTTOM ANGLE (TYP) (SIZE VARIES) COPE AND WELD L6x4x5/16 ANGLES BELOW FRP TUBE (SEE DETAIL 1/ST-4) PROPOSED 4'-0" LONG 3.0" STD MOUNTING PIPE PROPOSED 1/2" U-BOLT PROPOSED L3X3X1/4 BRACE ANGLE PROPOSED L3x3x1/4 CLIP ANGLE 2.75" LONG PROPOSED 1/2" A325 BOLT, FROM BALLAST ANGLES TO CLIP ANGLE NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. CUSTOM MOUNT PLAN DETAILS ST-4 17 1 ST-4 ANGLE WELDMENT DETAIL SCALE: N.T.S. 3 ST-4 CLIP ANGLE DETAIL SCALE: N.T.S. 2 ST-4 INTERIOR ANGLE CONNECTION DETAIL SCALE: N.T.S. 4 ST-4 MOUNT PIPE BRACE DETAIL SCALE: N.T.S. 03/30/18 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 PROPOSED 1/2" A325 THRU BOLT PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED L3x3x1/4 ANGLE PROPOSED 1/2" U-BOLT PROPOSED 4'-0" LONG 3.0" STD MOUNTING PIPE PROPOSED L3X3X1/4 BRACE ANGLE PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED 1/2" A325 THRU BOLT (TYP OF 4 PER TUBE) PROPOSED L6x4x5/16 INTERIOR ANGLE WELDMENT- THRU BOLT TO FRP TUBE, COPE AND WELD ANGLES PROPOSED 3/4" THRU BOLT (TYP OF FRP ANGLE BRACE CONNECTIONS) NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. 1 ST-3 TOP CONNECTION DETAIL SCALE: N.T.S. CUSTOM MOUNT ELEVATION DETAILS ST-3 16 3 ST-3 BRACING PLATE & ANGLE DETAIL SCALE: N.T.S. 5 ST-3 FRP & ANGLE DETAIL SCALE: N.T.S. 2 ST-3 TOP ANGLE DETAIL SCALE: N.T.S. 4 ST-3 MOUNT PIPE DETAIL SCALE: N.T.S. 03/30/18 R A D O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 PROPOSED L3x3x1/4 CLIP ANGLE (TYP OF 16) (SEE DETAIL 3/ST-4) PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED 1/2" A325 THRU BOLT FROM INTERIOR ANGLE WELDMENT TO FRP TUBE (TYP OF 4 PER POST) PROPOSED L3x3x1/4 BALLAST ANGLE - COPED AND WELDED (TYP OF 8) PROPOSED L6x4x5/16 INTERIOR ANGLE WELDMENT- THRU BOLTED TO FRP TUBE (TYP OF 4) PROPOSED L3x3x1/4 BALLAST ANGLE - BOLTED TO CLIP ANGLES (TYP OF 4) PROPOSED 1/2" A325 BOLT, FROM ANGLE TO CLIP ANGLE (TYP OF 32) COPE ANGLE AND WELD BELOW FRP TUBE ALL LOCATIONS (SEE DETAIL 1/ST-4) 1 ST-1 ST-4 3 ST-4 1 NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. PROPOSED L3X3X1/4 BRACE ANGLE (TYP OF 3) CUSTOM MOUNT PLAN ST-2 15 1 ST-2 CUSTOM SHROUD (PLAN) SCALE: N.T.S. 03/30/18 R O F E S S I O N A L E N G I N E E R 52731 2 ST-3 1 ST-2 NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. 1 ST-3 5 ST-4 4 ST-4 3 ST-3 1 ST-1 CUSTOM SHROUD (ELEVATION) SCALE: N.T.S. CUSTOM MOUNT ELEVATION ST-1 14 PROPOSED 1/4" THICK TOP PLATE PROPOSED 1/2" A325 THRU BOLT (TYP OF 8) PROPOSED 1/2" A325 BOLT, FROM TOP PLATE TO TOP ANGLES (TYP OF 4) PROPOSED L3x3x1/4 TOP ANGLE,THRU BOLT TO FRP TUBE (TYP OF 4) PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED 4'-0" LONG 3.0" STD MOUNTING PIPE PROPOSED 1/2" U-BOLT (TYP) PROPOSED L3x3x1/4 BRACE ANGLE (TYP OF 2) PROPOSED 1/2" A325 THRU BOLT (TYP OF 2) PROPOSED 3/4"Ø A325 THRU BOLT AT BRACE ANGLE TO POST CONNECTIONS (TYP) PROPOSED FRP L3x3x1/4 BRACE ANGLE - THRU BOLT TO FRP TUBE (TYP OF 2) PROPOSED L3x3x1/4 BALLAST ANGLE - COPED AND WELDED (TYP OF 8) PROPOSED 1/2" A325 THRU BOLT (TYP OF 2) PROPOSED L6x4x5/16 INTERIOR ANGLE WELDMENT - THRU BOLTED TO FRP TUBE - BOLTS NOT SHOWN FOR CLARITY (SEE DETAIL 5/ST-3) 03/30/18 E S S I O N A L E N G I N E E R 52731 PROPOSED LADDER CAGE PROPOSED LADDER TOP OF PARAPET (CONTRACTOR TO VERIFY EXACT HEIGHT PRIOR TO INSTALLATION) TOP OF ROOF TOP OF ROOF (CONTRACTOR TO VERIFY EXACT HEIGHT PRIOR TO INSTALLATION) CONSTRUCTION DETAILS (CONTINUED) C-8 13 1 C-8 CAGED LADDER ELEVATION DETAILS SCALE: 3/4" = 1'-0" 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 03/30/18 C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 NOTE: SEPARATION DIMENSIONS TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS. FINISHED GRADE OR PAVING. MATCH SLOPE AND THICKNESS OF EXISTING CONDITIONS 3"Ø SCH 40 PVC POWER CONDUIT (AS REQUIRED) BACKFILL (SAND OR NATIVE SOIL) PER ASTM STANDARDS UNDISTURBED SOIL UTILITY WARNING TAPE 2"Ø SCH 40 PVC FIBER CONDUIT (AS REQUIRED) 0.5 CDF SKID RESISTANT SURFACE 5/8"x4" PULL SLOT MAKE: HUBBELL 24"X36" FRP STRAIGHT WALL MODEL: B16243630A LIFTING INSERTS (4) CONSTRUCTION DETAILS (CONTINUED) C-7 12 1 C-7 UTILITY TRENCH DETAIL SCALE: N.T.S. 2 C-7 PULLBOX DETAIL SCALE: N.T.S. 03/30/18 R A D O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 INSTALL NEW FIBER FDP WITHIN PROPOSED EQUIPMENT CABINET (MULTILINK FWP-8SC-12SP) PROPOSED (4) 7/8" COAX CABLE PROPOSED COOPER DURA BLOK DB10 ROOFTOP SUPPORT PROPOSED SITE PRO 7/8" SNAP-IN HANGER W/SPRING NUT (TYP) NOTE: PROPOSED SPACING BETWEEN SLEEPERS IS 3' O.C. NOTES: 1. EXISTING CORES TO BE INSPECTED FOR EVIDENCE OF CUT RE-BAR, IF EVIDENCE OF CUT RE-BAR IS FOUND, CONTACT AERO SOLUTIONS LLC IMMEDIATELY TO INVESTIGATE FURTHER. 2. CONTRACTOR TO DRILL PILOT HOLES TO CHECK RE-BAR LOCATION BEFORE INSTALLATION OF ANY CONDUIT 3 C-6 WALL PENETRATION DETAIL SCALE: N.T.S. 1 C-6 EQUIPMENT CABINET DETAIL SCALE: N.T.S. 2 C-6 CABLE SLEEPER DETAIL SCALE: N.T.S. CONSTRUCTION DETAILS C-6 11 03/30/18 S I O N A L E N G I N E E R 52731 TOP OF EXISTING PARAPET RF TRANSPARENT MATERIAL SPECIFICATIONS FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES: 1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES. 2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING. 3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL. 4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPE. 5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION. 6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN DRAWINGS. 7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS FOLLOWS: 1/2" DIAMETER NUTS 8 FT-LBS TORQUE 5/8" DIAMETER NUTS 16 FT-LBS TORQUE 3/4" DIAMETER NUTS 24 FT-LBS TORQUE FIBERGLASS PANEL NOTES: BY LARSON CAMOFLAGE, LLC - FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN. - PANELS TO BE MINIMUM 1/4" THICKNESS. 1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF TRANSPARENT MATERIALS. 2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED APPEARANCE. 3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT. 4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT. 5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS: STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS. 6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE ULTRAVIOLET PROTECTION. 7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS. 8. CONTACT KEN PUEHL FOR ADDITIONAL INFORMATION AT 520-741-3115. PROPOSED SPARK ARRESTOR (BY OTHERS) (TO BE PAINTED TO MATCH SECOND FLOOR OF BUILDING) PROPOSED CHIMNEY CAP (BY OTHERS) (TO BE PAINTED TO MATCH SECOND FLOOR OF BUILDING) PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD (TO MATCH EXISTING STUCCO FINISH OF BUILDING) PROPOSED ANTENNA WITHIN CHIMNEY CONCEALMENT SHROUD PROPOSED ANTENNA MOUNTING PIPE WITHIN CHIMNEY CONCEALMENT SHROUD PROPOSED SPARK ARRESTOR (BY OTHERS) (TO BE PAINTED TO MATCH SECOND FLOOR OF BUILDING) PROPOSED CHIMNEY CAP (BY OTHERS) (TO BE PAINTED TO MATCH SECOND FLOOR OF BUILDING) PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD (TO MATCH EXISTING STUCCO FINISH OF BUILDING) FAUX CHIMNEY DETAIL C-5 10 1 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 .5 1 2 4 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 C-5 FAUX CHIMNEY DETAIL SCALE: 1"=1'-0" TOP OF EXISTING PARAPET 03/30/18 L E N G I N E E R 52731 LINE OF SIGHT NOTE: THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS A VISUAL REPRESENTATION OF HOW THE SITE WOULD APPEAR TO A 5'-8" PERSON STANDING ON THE SIDEWALK ACROSS N. COLLEGE AVE. LINE OF SIGHT ELEVATIONS C-4 9 PROPOSED LINE OF SIGHT FROM A 5'-8" PERSON STANDING IN THE MIDDLE OF THE SIDEWALK ACROSS N. COLLEGE AVE PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH CAP AND SPARK ARRESTOR (SHROUD TO MATCH EXISTING STUCCO FINISH OF BUILDING) (SEE SHEET C-5 FOR MORE DETAIL) NORTHERN LANES OF N. COLLEGE AVE. 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 C-4 LINE OF SIGHT ELEVATION SCALE: 1/8"=1'-0" 2 C-4 PERSPECTIVE ELEVATION SCALE: N.T.S. SOUTHERN LANES OF N. COLLEGE AVE. PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH CAP AND SPARK ARRESTOR (SHROUD TO MATCH EXISTING STUCCO FINISH OF BUILDING) (SEE SHEET C-5 FOR MORE DETAIL) EXISTING TREE (TYP) 03/30/18 R O F E S S I O N A L E N G I N E E R 52731 PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO BACKSIDE OF PARAPET WALL (SEE DETAIL 1/C-6) PROPOSED AWS RRH MOUNTED TO BACKSIDE OF PARAPET WALL (SEE DETAIL 1/A-2) PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH CAP AND SPARK ARRESTOR(SHROUD TO MATCH EXISTING STUCCO FINISH OF BUILDING) (SEE SHEET C-5 FOR MORE DETAIL) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM NON-PENETRATING SLED MOUNT WITH CONCEALMENT SHROUD(PAINT TO MATCH) (SEE DETAIL 2/A-1) 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS C-3 7 1 C-3 EXISTING NORTH ELEVATION SCALE: 1/8"=1'-0" 2 C-3 PROPOSED NORTH ELEVATION SCALE: 1/8"=1'-0" TOP OF UPPER PARAPET 35'-8" AGL GRADE 0'-0" AGL TOP OF LOWER PARAPET 24'-8" AGL TOP OF UPPER PARAPET 35'-8" AGL PROPOSED VERIZON RAD CENTER 41'-0" AGL TOP OF PROPOSED CONCEALMENT SHROUD 44'-4" AGL TOP OF LOWER PARAPET 24'-8" AGL GRADE 0'-0" AGL PROPOSED LADDERS WITH CAGES, TURNAROUND PLATFORMS AND SMALL LADDER FROM TOP OF PARAPET TO LOWER ROOF (INCLUDE ANTENNA ACCESS SIGNAGE) (LADDERS TO BE PAINTED TO MATCH WALL MOUNTED ON) (SEE SHEET C-8 FOR MORE DETAIL) EXISTING ROOF LINE EXISTING ROOF LINE PROPOSED PCS RRH MOUNTED TO BACKSIDE OF PARAPET WALL (SEE DETAIL 2/A-2) 03/30/18 A L E N G I N E E R 52731 N 1 C-2 EME PLAN SCALE: 3/8"=1'-0" 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 6 8 10 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EME PLAN C-2 7 QUANTITY: 1 QUANTITY: 3 QUANTITY: 2 RF NOTICE AND GUIDELINES SIGNS (2x) SHOULD BE INSTALLED ON THE FRONT AND REAR OF THE ANTENNA MOUNT GUIDELINES AND NOC SIGN SHOULD BE INSTALLED AT THE UPPER ROOF ACCESS LADDER NOTES: 1. FCC GUIDELINES AND NOC INFO SIGNS TO BE POSTED AT ALL PERMANENT ACCESS POINTS. 2. REFER TO FINAL EME DESIGN BY VERIZON PRIOR TO TURNING SITE ON. PROPOSED LADDER WITH CAGE, TURNAROUND PLATFORM AND SMALL LADDER FROM TOP OF PARAPET TO LOWER ROOF (INCLUDE ANTENNA ACCESS SIGNAGE) (LADDER TO BE PAINTED TO MATCH WALL MOUNTED ON) (SEE SHEET C-8 FOR MORE DETAIL) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM NON-PENETRATING SLED MOUNT WITH CONCEALMENT SHROUD(PAINT TO MATCH) (SEE DETAIL 2/A-1) 03/30/18 S I O N A L E N G I N E E R 52731 DESIGNATION CABLE TABLE LENGTH NO. TYPE CONDUIT WITH 3-CELL PLENUM FIBER IN CONDUIT FIBER RUN ±160' 1 2" SIZE MAXCELL INNERDUCT PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO BACKSIDE OF PARAPET WALL (SEE DETAIL 1/C-6) PROPOSED 5'-0"x10'-0" VERIZON LEASE AREA PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT (SEE DETAIL 1/C-7) (2) PROPOSED RRH'S MOUNTED TO BACKSIDE OF PARAPET WALL (SEE SHEET A-2 FOR MORE DETAIL) PROPOSED POWER ROUTED FROM NEW UTILITY METER MOUNTED ON LOWER EXTERIOR WALL N PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH CAP AND SPARK ARRESTOR(SHROUD TO MATCH EXISTING STUCCO FINISH OF BUILDING) (SEE SHEET C-5 FOR MORE DETAIL) PROPOSED EME SIGNAGE TO BE INSTALLED ON ANTENNA MOUNT (SEE SHEET C-2 FOR MORE DETAIL) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM NON-PENETRATING SLED MOUNT WITH CONCEALMENT SHROUD(PAINT TO MATCH) (SEE DETAIL 2/A-1) PROPOSED COAX ROUTED ON SLEEPERS FROM EQUIPMENT TO ANTENNA LOCATION (SEE DETAIL 2/C-6) PROPOSED 3'-0" WIDE TRAFFIC MAT FROM ROOF ACCESS POINT TO PROPOSED EQUIPMENT EXISTING UPPER ROOF 1 C-1 EQUIPMENT PLAN SCALE: 3/8"=1'-0" 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 6 8 10 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EQUIPMENT PLAN C-1 6 PROPOSED 100A LEVER-TYPE DISCONNECT MOUNTED TO BACKSIDE OF PARAPET WALL PROPOSED 100A POWER PANEL MOUNTED TO BACKSIDE OF PARAPET WALL 03/30/18 S E D P R O F E S S I O N A L E N G I N E E R 52731 1 Z-2 ENLARGED SITE PLAN SCALE: 1/4"=1'-0" 1/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 4 0 2 4 8 16 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO BACKSIDE OF PARAPET WALL (SEE DETAIL 1/C-6) PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH CAP AND SPARK ARRESTOR(SHROUD TO MATCH EXISTING STUCCO FINISH OF BUILDING) (SEE SHEET C-5 FOR MORE DETAIL) PROPOSED 5'-0"x10'-0" VERIZON LEASE AREA 1 C-3 PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT (SEE DETAIL 1/C-7) PROPOSED EME SIGNAGE TO BE INSTALLED ON ANTENNA MOUNT (SEE SHEET C-2 FOR MORE DETAIL) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM NON-PENETRATING SLED MOUNT WITH CONCEALMENT SHROUD(PAINT TO MATCH) (SEE DETAIL 2/A-1) (2) PROPOSED RRH'S MOUNTED TO BACKSIDE OF PARAPET WALL (SEE SHEET A-2 FOR MORE DETAIL) EXISTING UPPER ROOF PROPOSED POWER ROUTED FROM NEW UTILITY METER MOUNTED ON LOWER EXTERIOR WALL PROPOSED COAX ROUTED ON SLEEPERS FROM EQUIPMENT TO ANTENNA LOCATION (SEE DETAIL 2/C-6) PROPOSED 3'-0" WIDE TRAFFIC MAT FROM ROOF ACCESS POINT TO PROPOSED EQUIPMENT N ENLARGED SITE PLAN Z-2 5 PROPOSED 100A LEVER-TYPE DISCONNECT MOUNTED TO BACKSIDE OF PARAPET WALL PROPOSED 100A POWER PANEL MOUNTED TO BACKSIDE OF PARAPET WALL 03/30/18 C O L O R A D O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 N 1 Z-1 SITE PLAN SCALE: 1"=30'-0" PROPOSED VERIZON EQUIPMENT MOUNTED TO BACKSIDE OF PARAPET WALL (SEE DETAIL 1/C-6) LAPORTE AVE PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH CAP AND SPARK ARRESTOR(SHROUD TO MATCH EXISTING STUCCO FINISH OF BUILDING) (SEE SHEET C-5 FOR MORE DETAIL) PROPOSED 5'-0"x10'-0" VERIZON LEASE AREA 1 C-3 NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT (SEE DETAIL 1/C-7) 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 30 0 15 30 60 120 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) N. COLLEGE AVE PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM NON-PENETRATING SLED MOUNT WITH CONCEALMENT SHROUD(PAINT TO MATCH) (SEE DETAIL 2/A-1) (2) PROPOSED RRH'S MOUNTED TO BACKSIDE OF PARAPET WALL (SEE SHEET A-2 FOR MORE DETAIL) EXISTING UPPER ROOF EXISTING LOWER ROOF PROPOSED LADDERS WITH CAGES, TURNAROUND PLATFORMS AND SMALL LADDER FROM TOP OF PARAPET TO LOWER ROOF (INCLUDE ANTENNA ACCESS SIGNAGE) (LADDERS TO BE PAINTED TO MATCH WALL MOUNTED ON) (SEE SHEET C-8 FOR MORE DETAIL) PROPOSED 10'-0" WIDE ACCESS & UTILITY EASEMENT PROPOSED 2'X3' FIBER VAULT (SEE DETAIL 2/C-7) SITE PLAN Z-1 4 PROPOSED EME SIGNAGE TO BE INSTALLED ON UPPER ROOF ACCESS LADDER (SEE SHEET C-2 FOR MORE DETAIL) EXISTING 3 PHASE 300 kVA PAD MOUNTED TRANSFORMER. PROPOSED NEW POWER RUN FROM EXISTING TRANSFORMER TO NEW UTILITY METER AND DISCONNECT MOUNTED TO EXTERIOR WALL PROPOSED NEW MOTOR 03/30/18 L E N G I N E E R 52731 PHOTOSIMULATION VIEWS PH-1 3 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING WEST) N.T.S. 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING WEST) N.T.S. 3 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTHWEST) N.T.S. 4 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING NORTHWEST) N.T.S. 03/30/18 UE UE UE OT OT OT EV D O O O U/G U/G OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING SKYLIGHT HVAC UNIT AC SECURITY CAMERA VENT PIPE VP BOLLARD COMM DISH GROUNDING NOTES: 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. 2. ALL GROUNDING DEVICES SHALL BE U.L. APPROVED OR LISTED FOR THEIR INTENDED USE. 3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE. 4. GROUND WIRES SHALL BE #2 AWG BARE SOLID COPPER UNLESS NOTED OTHERWISE. 5. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC ("CADWELDS") TO GROUND RODS, GROUND RING WIRE, AND FENCE POSTS UNLESS NOTED OTHERWISE. CLEAN SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED TO GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZED PAINT. 6. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO-HOLE BRASS MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING SCREW SET.) CLEAN GROUND BAR TO SHINY METAL AFTER MECHANICAL CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING. 7. GROUND CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING KITS. 8. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 8" RADIUS. 9. PRIOR TO INSTALLING LUGS ON GROUND WIRES, APPLY THOMAS & BETTS KOPR-SHIELD (TM OF JET LUBE, INC.) PRIOR TO BOLTING GROUND WIRE LUGS TO GROUND BARS, APPLY KOPR-SHIELD OR EQUAL. 10. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY REMOVING ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING CONNECTION, APPLY APPROPRIATE ANTI-OXIDIZATION PAINT. REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 2 ELECTRICAL NOTES: 1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. ANY QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTORS FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. 2. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO ROUGH-IN. 3. THE CONDUIT RUNS AS SHOWN ON THE PLANS ARE APPROXIMATE. EXACT LOCATION AND ROUTING SHALL BE PER EXISTING FIELD CONDITIONS. 4. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY NEC. 5. ALL CONDUITS SHALL BE MET WITH BENDS MADE IN ACCORDANCE WITH NEC CHAPTER 9, TABLE #2. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER. 6. ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PLASTIC THROAT INSULATING GROUNDING BUSHINGS. 7. ALL WIRE SHALL BE TYPE THHN/THWN, SOLID, ANNEALED COPPER UP TO SIZE #10 AWG (#8 AND LARGER SHALL BE CONCENTRIC STRANDED) 75° C (167° F), 98% CONDUCTIVITY, MINIMUM #12. 8. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J-BOXES, EQUIPMENT BOXES AND CABINETS WITH APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY, OR APPROVED EQUAL. 9. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL. 10. CONDUIT ROUGH-IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTRACTOR AND COMPLY AS REQUIRED. 11. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN NOT HAND WRITTEN. 12. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL DISCONNECT SWITCHES, STARTERS, AND EQUIPMENT CABINETS. 13. THE CONTRACTOR SHALL PREPARE AS-BUILT DRAWINGS, DOCUMENT ANY AND ALL WIRING AND EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS CONTRACT. SUBMIT AT SUBSTANTIAL COMPLETION. 14. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED LAMICOID NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM (NO EXCEPTIONS.) 15. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) AS ADOPTED BY THE APPLICABLE STATE. 16. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR RISERS THROUGH BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS WITHOUT CONSTRUCTION MANAGER'S APPROVAL. SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE PACKED WITH FIRE RATED MATERIAL WHICH SHALL MAINTAIN THE FIRE RATING OF THE WALL OR STRUCTURE. FILL FOR FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. 17. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND EXISTING) SHALL BE FIELD VERIFIED WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN OF CONDUIT AND WIRE. ALL EQUIPMENT SHALL BE PROPERLY CONNECTED ACCORDING TO THE NAMEPLATE DATA FURNISHED ON THE EQUIPMENT (THE DESIGN OF THESE PLANS ARE BASED UPON BEST AVAILABLE INFORMATION AT THE TIME OF DESIGN AND SOME EQUIPMENT CHARACTERISTICS MAY VARY FROM DESIGN AS SHOWN ON THESE DRAWINGS). LOCATION OF ALL OUTLET, BOXES, ETC., AND THE TYPE OF CONNECTION (PLUG OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR TO ROUGH-IN. 03/30/18 AND SMALL LADDER DOWN FROM TOP OF PARAPET TO UPPER ROOF. TITLE SHEET T-1 JURISDICTION: CITY OF FORT COLLINS ZONING: D-DOWNTOWN DISTRICT APN: 97123-17-922 PARCEL SIZE: 14,244 S.F. ELEVATION: 4,983 (NAVD 88) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 35'-8" (TOP OF PARAPET) ANTENNA RAD CENTER: 41'-0" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: BRANDON KISER 9656 S. PROSPERITY RD WEST JORDAN, UT 84088 PH: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, CO 80301 PH: 720 279-8973 C-2 EME PLAN REVISION SCHEDULE REV 0 DATE 07-27-17 BY RPH 90% CONSTRUCTION DWG'S DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 23 SITE NAME: FTC UNIFY SC 01 SITE ADDRESS: 185 N. COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-16-0125 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 01-16-18 RPH REVISED CDs 2 03-28-18 RPH REVISED CDs C O L O R A D O L I C E N S E D P R O F E S S I O N A L E N G I N E E R 52731 VICINITY MAP C-3 ELEVATIONS VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: KENT McDERMOTT EMAIL: KENT.MCDERMOTT@VERIZONWIRELESS.COM LRK CONSULTING 1196 GRANT STREET, UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 C-4 LINE OF SIGHT ELEVATIONS C-5 FAUX CHIMNEY DETAILS C-6 CONSTRUCTION DETAILS (CONTINUED) A-1 ANTENNA SCHEDULE, MOUNTING PLAN & PLUMBING DIAGRAM G-1 GROUNDING PLAN G-2 GROUNDING DETAILS A-2 OVP & REMOTE RADIO HEAD DETAILS C-7 CONSTRUCTION DETAILS (CONTINUED) LEGAL DESCRIPTION E-1 ONE LINE DIAGRAM & PANEL SCHEDULE PH-1 PHOTOSIMULATION VIEWS GN-1 GENERAL NOTES LOT 22 AND 23, BLOCK 21 CITY OF FORT COLLINS, LARIMER COUNTY, COLORADO ST-1 CUSTOM MOUNT ELEVATION ST-2 CUSTOM MOUNT PLAN ST-3 CUSTOM MOUNT ELEVATION DETAILS ST-4 CUSTOM MOUNT PLAN DETAILS ST-5 STRUCTURAL NOTES C-8 CONSTRUCTION DETAILS (CONTINUED) PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS 1 03/30/18