HomeMy WebLinkAboutFTC MUGS COFFEE SC, WTE (VERIZON) - FDP - FDP180014 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSFTC MUGS COFFEE SC 714 S COLLEGE AVE FT. COLLINS, COLORADO 80524 SMALL CELL CONSTRUCTION DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: MERGE ONTO I-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W TOWARD DENVER. KEEP RIGHT AT THE FORK TO CONTINUE ON I-270 W, FOLLOW SIGNS FOR FORT COLLINS/BOULDER. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARD FT COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W, TURN LEFT ONTO S COLLEGE AVE, CONTINUE SOUTH ON COLLEGE AVE PAST LAUREL STREET, THE SITE AND PARKING ENTRANCE WILL BE ON THE LEFT. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER VENTUREPRO LLLP, ROBIN & CHRISTIAN BACHELET CONTACT: ROBIN BACHELET PHONE: 970-566-2586 EMAIL: RBACHELET@MAC.COM CONTACT: KENT McDERMOTT KENT.MCDERMOTT@VERIZONWIRELESS.COM AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: Ram.Nandiraju@verizonwireless.com RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 C-1 C-2 GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 07/18/17. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES.ANY WORK ASSOCIATED WITH THE ROOFING MEMBRANE SUCH AS ANCHORAGE, CONDUIT PLACEMENT, ADDED ISOLATION PADS, ETC. MUST BE INSTALLED BY A ROOFER THAT IS APPROVED BY THE MANUFACTURER OF THE INSTALLED ROOF MEMBRANE. 9. FINAL WORK SHALL BE PROPERLY SEALED AND WATERTIGHT. ALL DEBRIS SHALL BE REMOVED FROM THE ROOF AND PHOTOGRAPHIC RECORD OF FINAL CONDITION OF THE ROOF SHALL BE SENT TO THE OWNER'S REPRESENTATIVE. NOTIFICATION OF COMPLETION OF WORK SHALL BE DONE VIA THE AGREED UPON CHANNELS OF COMMUNICATION. 10. RF SIGNAGE TO BE INSTALLED AT ANY/ALL ROOF ACCESS POINTS ON THE BUILDING. GENERAL NOTES GN-1 2 LEGEND W W SS SS SS F F F GAS GAS GAS GAS GAS OE OE UT UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs PHOTOSIMULATION VIEWS PH-1 3 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING EAST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST) N.T.S. EM EM VP EM ET ET VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP (R/W VARIES) N 1 Z-1 SITE PLAN (ROOF LEVEL) SCALE: 1"=30'-0" SITE PLAN (ROOF LEVEL) Z-1 4 EXISTING CURB EM EM EM ET ET N 1 Z-2 SITE PLAN (GARAGE LEVEL) SCALE: 1"=30'-0" SITE PLAN (GARAGE LEVEL) 5 EXISTING CURB (TYP) EXISTING SIDEWALK PROPOSED VERIZON EQUIPMENT MOUNTED ON PARKING GARAGE WALL PROPOSED SHROUDED CABLE TRAY (SHROUD TO MATCH EXISTING DOWN SPOUTS) PROPOSED COAX ROUTED ALONG EXTERIOR OF BUILDING TO SHROUDED CABLE TRAY (SHROUD TO MATCH EXISTING DOWN SPOUTS) S COLLEGE AVE EXISTING FIBER LINE PROPOSED TRAFFIC RATED 2'-0"x3'-0" FIBER VAULT (SEE DETAIL 2/C-6) PROPOSED 5'-0" WIDE ACCESS AND UTILITY EASEMENT PROPOSED 5'-0"x10'-0" VERIZON LEASE AREA 2 C-3 2 C-2 EXISTING TREE (TYP) PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT (SEE DETAIL 1/C-6) PROPOSED ELECTRICAL FROM EXISTING ELECTRICAL PANEL IN GARAGE TO NEW EQUIPMENT (PANEL H1A) REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 EM EM EM 10'-0" 5'-0" VP VP VP VP VP VP VP 4'-3" 17'-6" A SECTOR CABLE TABLE N/A AZIMUTH 80'-0" LENGTH 2 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 7/8" COAX N PROPOSED EQUIPMENT CABINET MOUNTED TO PARKING GARGAE WALL (SEE DETAIL 1/C-5) PROPOSED POWER PANEL MOUNTED TO PARKING GARAGE WALL PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE (SEE SHEET C-5 FOR MORE DETAIL) PROPOSED AWS RRH MOUNTED ON UNISTRUT TO PARKING GARAGE WALL (SEE DETAIL 1/A-2) PROPOSED QUASI-OMNI ANTENNA MOUNTED ON CUSTOM NON-PENETRATING PEAK MOUNT (SEE DETAIL 2/A-1) PROPOSED CUSTOM NON-PENETRATING PEAK ROOF MOUNT (SEE SHEETS ST-1 THROUGH ST-5 FOR MORE DETAIL) 1 C-1 EQUIPMENT PLAN (ROOF LEVEL) SCALE: 1/8"=1'-0" 2 C-1 EQUIPMENT PLAN (GARAGE LEVEL) SCALE: 1/8"=1'-0" 1 C-2 44'-9" 48'-4" 40'-0" 40'-0" REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs NOTE: FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE. 2 C-2 PROPOSED WEST ELEVATION SCALE: 1/8" = 1'-0" PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S FACADE PROPOSED VERIZON RAD CENTER 44'-9" AGL TOP OF ROOF 40'-0" AGL TOP OF PROPOSED SHROUD 48'-4" AGL 1 C-2 EXISTING WEST ELEVATION SCALE: 1/8" = 1'-0" TOP OF ROOF 40'-0" AGL PROPOSED COAX ROUTED ALONG EXTERIOR OF BUILDING TO SHROUDED CABLE TRAY 40'-0" 44'-9" 48'-6" 40'-0" REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 2 C-3 PROPOSED NORTH ELEVATION SCALE: 1/8" = 1'-0" 1 C-3 EXISTING NORTH ELEVATION SCALE: 1/8" = 1'-0" PROPOSED VERIZON RAD CENTER 44'-9" AGL TOP OF ROOF 40'-0" AGL TOP OF PROPOSED SHROUD 48'-4" AGL PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S FACADE PROPOSED COAX ROUTED ALONG EXTERIOR OF BUILDING TO SHROUDED CABLE TRAY (SHROUD TO MATCH EXISTING DOWN SPOUTS) PROPOSED QUASI-OMNI ANTENNA MOUNTED ON CUSTOM NON-PENETRATING PEAK MOUNT (SEE DETAIL 2/A-1) PROPOSED CUSTOM NON-PENETRATING REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 1 C-4 FAUX CHIMNEY DETAILS SCALE: 1"=1'-0" TOP OF EXISTING ROOF PROPOSED ANTENNA MOUNTING PIPE (TYP) PROPOSED QUASI OMNI ANTENNA WITHIN CHIMNEY CONCEALMENT SHROUD PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH SPARK ARRESTOR (SHROUD TO BE PAINTED AND TEXTURED TO MATCH BUILDING) PROPOSED CHIMNEY CAP RF TRANSPARENT MATERIAL SPECIFICATIONS FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES: 1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES. 2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING. 3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL. 4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPE. 5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION. 6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN DRAWINGS. 7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS FOLLOWS: 1/2" DIAMETER NUTS 8 FT-LBS TORQUE 5/8" DIAMETER NUTS 16 FT-LBS TORQUE 3/4" DIAMETER NUTS 24 FT-LBS TORQUE FIBERGLASS PANEL NOTES: BY LARSON CAMOFLAGE, LLC 2'-8" 1'-11" 1'-0" 2'-1" 2'-1" 1'-10" CHARLES CUBE SMALL CELL CABINET MODEL: RL11411AN1 CABINET WEIGHT: 82LBS. (AS SHIPPED) U.L. SYSTEM NO. CAJI150 METAL PIPE/CONDUIT THROUGH CONCRETE FLOOR OR WALL F RATING = 3-HR T RATING = 0-HR TOP VIEW A A SECTION A-A REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 1 C-5 EQUIPMENT CABINET DETAIL N.T.S. 2 C-5 WALL PENETRATION DETAIL N.T.S. NOTES: 1. EXISTING CORES TO BE INSPECTED FOR EVIDENCE OF CUT RE-BAR, IF 4" 2'-6" 1'-6" 6" MIN. (TYP) 4" MIN. TO SECONDARY ELECTRIC 12" MIN. TO PRIMARY ELECTRIC NOTES: 1. CONTRACTOR TO ORDER HANDHOLE BOX WITH THE CORRECT NUMBER AND SIZE OF KNOCKOUTS NEEDED. 2. VERIFY DIMENSIONS OF UNIT. 24" 26" 30" BOX COVER 37 5/8" 35 3/8" REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs NOTE: SEPARATION DIMENSIONS TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS. 1 C-6 UTILITY TRENCH DETAIL N.T.S. 2 C-6 PULLBOX DETAIL N.T.S. FINISHED GRADE OR PAVING. 1'-8" 4" 2 1/8" 2 1/4" 1 1/2" 7'-2 7/8" 9 1/4" TOP OF PEAK 40'-0" 6" 3" RAD CENTER 44'-9" 1'-5" 1'-8" 1 1/2" TYP. 1 1/2" TYP. 1" TYP. 3" 1 1/4" 1 1/4" 2 1/4" 1 1/2" 1'-5" 1 ST-1 CUSTOM SHROUD (ELEVATION) N.T.S. PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED 1/2" A325 THRU BOLT (TYP OF 8) PROPOSED L4x4x1/4 FRP TOP ANGLE, THRU BOLT TO FRP TUBE (TYP OF 4) PROPOSED 1/2" U-BOLT (TYP OF 2) PROPOSED 1'-9" LONG 2.0" STD MOUNTING PIPE PROPOSED L6x3.5x5/16 COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE (REF 2/ST-3) NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. PROPOSED 3"x6" WELDED PLATE WITH SLOTTED HOLES 2 ST-1 3 ST-1 3'-10" 1'-8" 8 1/2" TYP. 3" TYP. 8'-0" 3'-1 11/16" 3'-1 11/16" 1" 1 1/4" 1 1/4" 3'-10" 1 ST-2 CUSTOM BALLAST TRAY (PLAN) N.T.S. PROPOSED 2"X3" SPACER PLATE (TYP. OF 2) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 1/2" A325 BOLT ST-2 2 ST-2 3 NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 6" 3 1/2" 5 1/2" 5" 2" 6" 2 1/8" 2 1/16" 1 3/4" 2 3/16" 13/16" 5'-3 3/8" 3 1/2" 3'-5 3/8" 2 ST-3 FRP COLUMN CONNECTION N.T.S. 1 ST-3 PEAK CONNECTION DETAIL N.T.S. 4 ST-3 3D RENDERING N.T.S. PROPOSED 1/2" A325 THRU BOLT (TYP. 2 PER CONNECTION) PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) 3 ST-3 BALLAST TO FRAME CONNECTION N.T.S. NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: STRUCTURAL NOTES: 1. DESIGN INFORMATION AND GENERAL REQUIREMENTS 1.1 CODES a. DESIGN CONFORMS TO 2015 INTERNATIONAL BUILDING CODE. b. ASCE 7-10 MIN. DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES. c. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, ANSI/AISC 360-10. 1.2 MISCELLANEOUS a. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. 2. STRUCTURAL STEEL 2.1 MATERIALS a. STRUCTURAL STEEL. . . . . . . . ASTM A992 CHANNEL . . . . . . . . . . . . . . . . . . .ASTM A36 ANGLES, PLATE & MISC. . . . . . ASTM A36 RECTANGULAR HSS . . . . . . . . . ASTM A500, GRADE B, Fy=46 ksi ROUND HSS . . . . . . . . . . . . . . . . ASTM A500, GRADE B, Fy=42 ksi PIPES . . . . . . . . . . . . . . . . . . . . . ASTM A53, GRADE B b. BOLTS . . . . . . . . . . . . . . . . . . . . ASTM A325 U.N.O. c. WELDING ELECTRODES . . . . . . . . AWS A5.1 (E70XX) d. STEEL CONSTRUCTION SHALL CONFORM TO "SPECIFICATION FOR STRUCTURAL STEEL FOR BUILDINGS - 14TH EDITION". e. WELDING SHALL CONFORM TO AWS D1.1 "STRUCTURAL WELDING CODE". f. THE FABRICATOR SHALL FURNISH CHECKED SHOP AND ERECTION DRAWINGS TO THE ENGINEER, AND OBTAIN APPROVAL PRIOR TO FABRICATING ANY STRUCTURAL STEEL. SHOP DRAWINGS SHALL CONFORM TO AISC "DETAILING FOR STEEL CONSTRUCTION". 2.2 CONNECTIONS a. SHOP CONNECTIONS MAY BE BOLTED OR WELDED. b. FIELD CONNECTIONS SHALL BE BOLTED WITH A325-N BOLTS, (INSTALLED SNUG TIGHT) UNLESS OTHERWISE SPECIFIED OR IF WELDED CONNECTIONS ARE NOTED ON DRAWINGS. c. FIELD CONNECTIONS SHALL BE MADE WITH HIGH TENSILE BOLTS AND HARDENED WASHERS EXCEPT AS INDICATED ON THE DESIGN DRAWINGS. d. CONNECTIONS NOT SHOWN ON DRAWINGS SHALL BE DESIGNED BY THE STEEL FABRICATOR. CONNECTIONS SHALL BE DESIGNED IN ACCORDANCE WITH AISC "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" AND AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". e. DO NOT FIELD CUT OR ALTER STRUCTURAL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL OF ENGINEER. 2.3 FINISHES a. STRUCTURAL STEEL SHALL BE HOT DIP GALVANIZED AFTER FABRICATION PER ASTM A123 b. ALL STEEL SHALL BE CLEANED OF RUST, LOOSE MILL SCALE AND OTHER FOREIGN MATERIALS AND BE HOT DIPPED GALVANIZED OR STAINLESS STEEL IF OTHERWISE INDICATED ON PLAN. c. FIELD FABRICATIONS SHALL BE TREATED WITH ZRC COLD GALVANIZING COMPOUND OR EQUAL PRIOR TO ASSEMBLY. d. BOLTS AND NUTS SHALL BE HOT DIP GALVANIZED PER ASTM A153. 3.1 MATERIALS a. USE STRONGWELL EXTREN FIBERGLASS STRUCTURES SERIES 625 TUBES AND ANGLES UNLESS OTHERWISE NOTED. b. FRP PANELS ARE TO BE UV RESISTANT FOR EXTERIOR EXPOSURE AND MUST BE RF TRANSPARENT TO ALLOW UNIMPEDED ANTENNA/MICROWAVE DISH SIGNAL PROPAGATION. c. ATTACH PANEL ACCORDING TO MANUFACTURERS RECOMMENDATIONS. d. FRP MATERIALS ARE TO BE CONSTRUCTED TO MEET ALL OF THE MANUFACTURERS REQUIREMENTS. e. DO NOT ALTER STRUCTURAL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL OF ENGINEER OF RECORD. f. FRP MEMBERS MAY BE SAWED, DRILLED, ROUTED, AND TURNED ON A LATHE OR OTHER MACHINE TOOL. PUNCHING SHALL NOT BE PERMITTED. CARBIDE OR DIAMOND TIPPED TOOLS ARE RECOMMENDED. g. FRP MEMBERS MAY BE FASTENED MECHANICALLY USING SCREWS, BOLTS, OR RIVETS. FIBERBOLT FIBERGLASS STUDS AND HEX HEADS SHOULD BE USED ONLY WHERE SPECIFICALLY SHOWN IN THE DESIGN DRAWINGS. h. FRP MEMBERS MAY BE CONNECTED WITH ADHESIVE ONLY IF USED IN CONJUNCTION WITH THE SPECIFIED MECHANICAL FASTENERS. 3. FIBER REINFORCED POLYMER REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC 4'-9" REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. 2 A-1 ANTENNA MOUNTING DETAIL SCALE: 3/8" = 1'-0" 1 A-1 PROPOSED ANTENNA LAYOUT SCALE: 1/4" = 1'-0" N ANTENNA & CABLE SCHEDULE SECTOR AZIMUTH MOUNTING HEIGHT ANTENNA MODEL TECHNOLOGY ANTENNA SPECIFICATIONS MECHANICAL DOWNTILT ELECTRICAL DOWNTILT CABLE SIZE CABLE LENGTH A N/A 44'-9" 25.8" RRH WEIGHT: 56.8 LBS ISOMETRIC VIEW 7.3" 12" TOP VIEW BOTTOM VIEW 7.2" 12" TOP VIEW BOTTOM VIEW 21.4" ISOMETRIC VIEW RRH WEIGHT: 53 LBS REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 1 A-2 AWS RRH DETAIL N.T.S. POWER (-48VDC) ALARM PORT AISG PORT CPRI 2 CPRI 1 ALARM PORT AISG PORT CPRI 2 CPRI 1 POWER (-48VDC) M REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 1 E-1 ONE-LINE DIAGRAM N.T.S. 2 E-1 ONE-LINE ELEVATION N.T.S. NEW 22K+ AIC-RATED 400A LOAD CENTER TO REPLACE EXISTING FAULT: 12,365A (L-L) EXISTING 500KVA, 120/208V 3Ø TRANSFORMER FAULT: 49,355 A EXISTING 400A METER (20' FROM DISCONNECT) FAULT: 19,667A EXISTING 3 1/2" PVC CONDUIT (4) 500 KCMIL AL CONDUCTOR (40' RUN) NOTES: 1. TOTAL VERIZON LOAD TO BE APPROX 19.25A. 2. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT, REFER TO VENDOR PRINTS PROVIDED BY EQUIPMENT CABINET MANUFACTURER.. 3. CONTRACTOR TO INSTALL SCH80 PVC FOR ALL CONDUIT SWEEPS, OTHERWISE SCH40 PVC IS ACCEPTABLE EXCEPT WHERE NOTED. 4. CONTRACTOR TO FURNISH PROPOSED PANEL WITH 22K AIC-RATED BREAKERS AND PROVIDE REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs LOAD STUDY 19 E-2 REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs LOAD STUDY 20 E-3 PROPOSED UNISTRUT PROPOSED RRH'S (2) #2 GREEN THHN GROUND WIRE TO GROUND ROD AT GRADE (FOLLOW FIBER ROUTE TO GRADE) 5/8"Ø x 10' LONG COPPER GROUND ROD (BURY 36" BFG) PROPOSED EQUIPMENT GROUND BAR #6 GREEN THHN GROUND WIRE PROPOSED COAX GROUND LEAD FROM MOUNT STEEL TO GROUND BAR PROPOSED ANTENNA GROUND BAR PROPOSED COAX GROUNDING KIT #6 SOLID TINNED GROUND WIRE PROPOSED ANTENNA PROPOSED CUSTOM MOUNT PROPOSED EQUIPMENT CABINET REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) TYPE NC TYPE GT TYPE GL LUG TYPE HA TYPE GR TYPE VS TYPE HS TYPE SS TYPE XA TYPE PT (2) (3) (5) (4) (1) GALVANIZED STEEL GROUND BAR, BY ELECTRIC MOTION COMPANY (SEE SCHEDULE BELOW). INSULATORS, BY HARGER CAT. #5263-A5. 5/8 " LOCKWASHERS, STAINLESS STEEL. WALL MOUNTING BRACKET, HARGER CAT. #WBKT-2. 5/8-11x3" H.H.C.S. BOLTS, STAINLESS STEEL. LEGEND "GALV STEEL" STEEL STAMPED ON EITHER END CADWELD AT TWO LOCATIONS REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 4 G-2 ANTENNA GROUND BAR CONNECTIONS N.T.S. 1 G-2 TYPICAL CABLE GROUNDING N.T.S. CABLE TO ANTENNA CABLE GROUNDING CLAMP KIT #6 AWG GREEN INSULATED COPPER GROUNDING CONDUCTOR CABLE TO EQUIPMENT 3M SCOTCH SUPER 33+ VINYL ELECTRICAL TAPE (OR APPROVED EQUAL) PROPOSED COAX VAPOR WRAP SEALANT COAX TO JUMPER CONNECTION PROPOSED JUMPER 3 G-2 TYPICAL CADWELD TYPE CONNECTIONS N.T.S. WEATHERPROOFING KIT (TYP) RX1/RX2 TX1/TX2 STANDARD GROUND KIT (TYP) #6 AWG STRANDED Cu WIRE WITH GREEN, 600V, THWN INSULATION GROUND BAR, MOUNTED NEAR/BELOW ANTENNA #2 AWG Cu STRANDED WIRE WITH GREEN, 600V, THWN INSULATION BONDED TO GROUND BAR AT GRADE JUMPER REQUIRED ONLY FOR EASE OF CONNECTION AND STRESS REDUCTION ON ANTENNA CONNECTORS (TYP) CONNECTOR WATERPROOFING KIT (TYP) TO ANTENNA NOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO CRGB 5 G-2 GROUND BAR DETAIL N.T.S. 2 G-2 WEATHERPROOFING DETAIL N.T.S. GROUNDING DETAILS 22 G-2 1 03-27-18 LCW 100% CDs 1 G-1 ANTENNA/RRH GROUNDING DETAIL SCALE: NTS GROUNDING PLAN 21 G-1 PROPER ARC FLASH WARNING LABELS ON PANEL EXISTING 500KVA 120/208V 3Ø TRANSFORMER FAULT = 49,355 A EXISTING 3 1/2" PVC CONDUIT WITH (4) 500 KCMIL AL CONDUCTORS (40' RUN) EXISTING 400A LEVER-TYPE DISCONNECT EXISTING 400A METER FAULT: 19,667A (L-L) PROPOSED E-MON D-MON CHECK METER NEW 22K+ AIC-RATED 400A LOAD CENTER TO REPLACE EXISTING FAULT: 12,365A (L-L) PROPOSED 2" PVC CONDUIT WITH (3) #4 AWG CU CONDUCTORS (1) #10 AWG CU GROUND (60' RUN) PROPOSED (3) - #4 AWG CU CONDUCTOR, (1)-#10 CU GND IN 2" PVC CONDUIT (60' RUN) PROPOSED 400A, 120/208V, 3Ø, 4W PANEL SCHEDULE LOAD SERVED 2ND FLR HALL LIGHTS VOLT AMPS VOLT AMPERES (WATTS) L1 L2 20A TRIP CKT # PHASE CKT # TRIP VOLT AMPERES L1 L2 VOLT AMPERES (WATTS) LOAD SERVED 1 3 5 7 2 4 6 8 20A AMPS MAX AMPS MAX AMPS x125% 314.4 393.03 20A 9 11 13 15 10 12 14 16 SW WH 20A SW SPRKLER GARAGE/CLOSET 17 19 21 23 18 20 22 24 20A FACP POWER 25 27 29 31 26 28 30 32 33 35 34 36 30A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A SW BATH LIGHTS NE BATH HEAT 20A 30A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A PH. OUTLET 3RD FLR 20A 20A NE WH 30A EAST COURTYARD OUTLETS 125A ELEVATOR SHUNT TRIP NE BATHROOM 37 38 A SW CORRIDOR A 39 C 40 A A C C B C B A B A B B B C C 37731 37522 36903 314.4 312.7 307.5 41 42 A B C 175A ELEVATOR SHUNT TRIP L3 L2 L1 L2 L3 VOLT AMPS UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN 1500 1680 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - VERIZON PROPOSED 100A VZW SUB-PANEL FAULT: 4,315A (L-L) 100A, 120/208V, 1Ø, 3W PROPOSED SUB-PANEL SCHEDULE LOAD SERVED RECTIFIER #1 GFCI SPARE VOLT AMPS VOLT AMPERES (WATTS) L1 L2 500 20A 25A TRIP CKT # PHASE CKT # TRIP L1 VOLT AMPERES L2 VOLT AMPERES 500 - L1 L2 180 680 RECTIFIER #2 RECTIFIER #3 VOLT AMPERES (WATTS) LOAD SERVED 1 3 5 7 A C A C 2 4 6 8 25A 25A 500 500 500 500 L1 AMPS L2 AMPS MAX AMPS MAX AMPS x125% X 110% FOR MAIN 500 1000 1000 VOLT AMPS - PROPOSED VZW 100A SUB-PANEL FAULT: 4,315A (L-L) EXISTING 400A LEVER TYPE DISCONNECT PROPOSED E-MON D-MON CHECK METER COURTYARD LIGHTS ONE LINE DIAGRAM & PANEL SCHEDULE 18 E-1 EXISTING 400A LEVER TYPE DISCONNECT FAULT: 23,074A (L-L) EXISTING (4) 500 KCMIL CU OPEN AIR CONDUCTOR (20'' RUN) EXISTING JUNCTION BOX FAULT: 27,908A (L-L) EXISTING JUNCTION BOX FAULT: 27,908A (L-L) EXISTING (4)- 500 KCMIL CU OPEN AIR CONDUCTORS (20' RUN) EXISTING 400A LEVER TYPE DISCONNECT FAULT: 23,074A (L-L) EXISTING (4)- 500 KCMIL CU CONDUCTOR IN 3" PVC CONDUIT (80' RUN) EXISTING (4)- 500 KCMIL CU OPEN AIR CONDUCTORS (20' RUN) EXISTING (4)- 500 KCMIL CU CONDUCTOR IN 3" PVC CONDUIT (80' RUN) 2 A-2 PCS RRH DETAIL N.T.S. OVP & REMOTE RADIO HEAD DETAILS 17 A-2 OMNI ANTENNA PCS/AWS 39"(H) X 12"(D) 33.5 LBS 0° 0° (2) 7/8" COAX 80 FT. PROPOSED OMNI ANTENNA PROPOSED ANTENNA MOUNT(COMMSCOPE MC-MNT-TS1) PROPOSED 1'-9" LONG 2.0" STD MOUNTING PIPE PROPOSED CUSTOM NON-PENETRATING MOUNT (SEE SHEETS ST-1 THROUGH ST-5 FOR MORE DETAIL) ACCORDING TO THE STRUCTURAL ANALYSIS BY AERO SOLUTIONS, LLC DATED 11/17/17, THE PROPOSED MOUNT REQUIRES A MINIMUM OF 280 LBS OF BALLAST PER SIDE, 560 LBS TOTAL PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE (SEE SHEET C-5 FOR MORE DETAIL) PROPOSED QUASI-OMNI ANTENNA MOUNTED ON CUSTOM NON-PENETRATING PEAK MOUNT (SEE DETAIL 2/A-1) PROPOSED CUSTOM NON-PENETRATING PEAK ROOF MOUNT (SEE SHEETS ST-1 THROUGH ST-5 FOR MORE DETAIL) PROPOSED SHROUDED CABLE TRAY (SHROUD TO MATCH EXISTING DOWN SPOUTS) EXISTING LADDER PROPOSED EQUIPMENT CABINET MOUNTED TO PARKING GARGAE WALL (SEE DETAIL 1/C-5) PROPOSED AWS RRH MOUNTED ON UNISTRUT TO PARKING GARAGE WALL (SEE DETAIL 1/A-2) PROPOSED COAX ROUTED ALONG EXTERIOR OF BUILDING TO SHROUDED CABLE TRAY (SHROUD TO MATCH EXISTING DOWN SPOUTS) PROPOSED PCS RRH MOUNTED ON UNISTRUT TO PARKING GARAGE WALL (SEE DETAIL 2/A-2) 0.5 0 1 2 3 4 5 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 4 0 2 4 8 16 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ANTENNA SCHEDULE, MOUNTING PLAN & PLUMBING DIAGRAM 16 A-1 CONFIGURATION QUASI-OMNI ANTENNA PCS RRH DIPLEXER DIPLEXER AWS RRH EQUIPMENT CABINET 7/8" COAX (TYP) 1/2" COAX (TYP) DC CABLES & FIBER JUMPERS (TYP) 3 A-1 PLUMBING DIAGRAM SCALE: NTS SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs STRUCTURAL NOTES 15 ST-4 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs FRONT SIDE PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE PROPOSED 5"x1/4" SPACER PLATE (ONE SIDE) (TYP. OF 2) PROPOSED 6"x1/4" WELDED CONNECTION PLATE (TYP. OF 4) NOTE: CONNECTION BOLTS NOT SHOWN FOR CLARITY. SEE FRONT DETAIL PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE PROPOSED 5"x1/4" SPACER PLATE (ONE SIDE) (TYP. OF 2) PROPOSED 6"x1/4" WELDED CONNECTION PLATE (TYP. OF 4) PROPOSED 1/2" A325 CONNECTION BOLT IN SLOTTED HOLES (TYP.) PROPOSED 1/2" A325 SET BOLT FIELD DRILL FOR ROOF SLOPE PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE PROPOSED L6"x3.5"x5/16" BRACE ANGLE WELDED TO COLUMN SUPPORT ANGLES PROPOSED L3x3x3/16" CLIP ANGLES WELDED TO BALLAST TRAY PROPOSED L3x3x3/16"BALLAST ANGLE 1/8 1/8 TYP 1/8 1/8 TYP 1/8 1/8 TYP PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE EXISTING ROOF PEAK LINE NOTE: SHROUD AND RELATED MEMBERS ARE NOT SHOWN FOR CLARITY CUSTOM MOUNT ELEVATION DETAILS 14 ST-3 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 2 ST-2 BALLAST TRAY DETAIL (NEAR SHROUD) N.T.S. 3 ST-2 BALLAST TRAY DETAIL (AWAY FROM SHROUD) N.T.S. 4 ST-2 4 ST-2 BALLAST TRAY DETAIL (SIDE N.T.S. PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT COPE ANGLES AND WELD (ALL CORNERS) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 1/2" A325 BOLT (TYP.) PROPOSED L3x3x3/16 VERTICAL BALLAST ANGLE PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT COPE ANGLES AND WELD (ALL CORNERS) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED CMU BALLAST PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT PROPOSED 2"X3" SPACER PLATE (TYP. OF 2) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 1/2" A325 BOLT (TYP.) PROPOSED L3x3x3/16 VERTICAL BALLAST ANGLE PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT PROPOSED L3x3x3/16 BALLAST ANGLE ST-3 3 PROPOSED 2"X3" SPACER PLATE (TYP. OF 2) PROPOSED L3x3x3/16 BALLAST ANGLE (TYP.) PROPOSED 1/2" A325 BOLT (TYP.) PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT COPE ANGLES AND WELD (ALL CORNERS) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 1/2" A325 BOLT (TYP.) PROPOSED L6x3.5x5/16 ANGLE WELDED TO BALLAST TRAY CJP 1/8 CJP CUSTOM MOUNT BALLAST TRAY 13 ST-2 3 ST-1 CUSTOM SHROUD MOUNT DETAIL N.T.S. 2 ST-1 CUSTOM SHROUD TOP DETAIL N.T.S. 3 ST-1 1 2 ST-3 ST-3 PROPOSED L6x3.5x5/16 COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE (REF 2/ST-3) PROPOSED 1/2" A325 THRU BOLT (TYP OF 8) PROPOSED L4x4x1/4 FRP TOP ANGLE, THRU BOLT TO FRP TUBE (TYP OF 4) PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) TOP SIDE PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED L3x3x3/16 COLUMN SUPPORT ANGLE (TYP OF 4) PROPOSED 1/2" U-BOLT (TYP OF 2) PROPOSED 2'-4" LONG 2.0" STD MOUNTING PIPE PROPOSED 1/2" U-BOLT (TYP OF 2) PROPOSED 2'-4" LONG 2.0" STD MOUNTING PIPE PROPOSED 1/2" A325 THRU BOLT (TYP OF 8) PROPOSED 1/2" A325 THRU BOLT PROPOSED 1/2" A325 BOLT PROPOSED L3x3x3/16 COLUMN SUPPORT ANGLE (TYP OF 4) PROPOSED L6x3.5x5/16" MOUNT ANGLE (TYP OF 1) REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs PROPOSED L6x3.5x5/16 BRACING ANGLES WELDED TO FRP TUBE (REF 2/ST-3) CUSTOM MOUNT ELEVATION 12 ST-1 MATCH SLOPE AND THICKNESS OF EXISTING CONDITIONS 3"Ø SCH 40 PVC POWER CONDUIT (AS REQUIRED) BACKFILL (SAND OR NATIVE SOIL) PER ASTM STANDARDS UNDISTURBED SOIL UTILITY WARNING TAPE 2"Ø SCH 40 PVC FIBER CONDUIT (AS REQUIRED) 0.5 CDF SKID RESISTANT SURFACE 5/8"x4" PULL SLOT MAKE: HUBBELL 24"X36" FRP STRAIGHT WALL MODEL: B16243630A LIFTING INSERTS (4) CONSTRUCTION DETAILS (CONTINUED) 11 C-6 EVIDENCE OF CUT RE-BAR IS FOUND, CONTACT AERO SOLUTIONS LLC IMMEDIATELY TO INVESTIGATE FURTHER. 2. CONTRACTOR TO DRILL PILOT HOLES TO CHECK RE-BAR LOCATION BEFORE INSTALLATION OF ANY CONDUIT 4 C-5 GARAGE EQUIPMENT ELEVATION SCALE: 3/4" = 1'-0" PROPOSED NEMA 3R RATED EQUIPMENT CABINET MOUNTED TO GARAGE WALL (SEE DETAIL 1/C-5) PROPOSED 100A ELECTRICAL SUB P1000 GALVANIZED UNISTRUT PANEL MOUNTED TO GARAGE WALL (DETERMINE SPACING IN FIELD) PROPOSED AWS RRH MOUNTED ON UNISTRUT TO PARKING GARAGE WALL (SEE DETAIL 1/A-2) PROPOSED PCS RRH MOUNTED ON UNISTRUT TO PARKING GARAGE WALL (SEE DETAIL 2/A-2) 5 C-5 COAX ROUTING DETAIL SCALE: 1/2" = 1'-0" PROPOSED VERIZON ANTENNA PROPOSED SHROUDED CUSTOM SLED MOUNT (2) PROPOSED 7/8" COAX (2) PROPOSED 1/2" COAX JUMPERS PROPOSED SHROUD 5 C-5 COAX ATTACHMENT (HORIZONTAL) N.T.S. EXISTING WALL PROPOSED P1000 UNISTRUT (SPACED 3'-0" O.C MAX) PROPOSED 1/2"Øx4" LAG SCREW IN STUD OR 1/2" EXPANDING ANCHOR INTO CMU WALL (CONTRACTOR TO VERIFY) PROPOSED 7/8" COAX WITH SNAP STACK (TYP) PROPOSED P1000 UNISTRUT (SPACED 3'-0" O.C MAX) PROPOSED 1/2"Øx4" LAG SCREW IN STUD OR 1/2" EXPANDING ANCHOR INTO CMU WALL (CONTRACTOR TO VERIFY) PROPOSED SHROUD (BY CONTRACTOR) PROPOSED 7/8" COAX WITH SNAP STACK (TYP) EXISTING WALL 6 C-5 COAX ATTACHMENT (VERTICAL) N.T.S. PROPOSED SHROUD AND UNISTRUT TO BE PAINTED TO MATCH BUILDING 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 CONSTRUCTION DETAILS 10 C-5 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1/2" COAX 7/8" COAX DUPLEXERS - FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN. - PANELS TO BE MINIMUM 1/4" THICKNESS. 1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF TRANSPARENT MATERIALS. 2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED APPEARANCE. 3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT. 4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT. 5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS: STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS. 6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE ULTRAVIOLET PROTECTION. 7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN. 8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS. 9. CONTACT KEN PUEHL FOR ADDITIONAL INFORMATION AT 520-741-3115. PROPOSED CHIMNEY CAP TOP OF EXISTING ROOF 1 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 .5 1 2 4 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) FAUX CHIMNEY DETAILS 9 C-4 PEAK ROOF MOUNT (SEE SHEETS ST-1 THROUGH ST-5 FOR MORE DETAIL) PROPOSED AWS RRH MOUNTED ON UNISTRUT TO PARKING GARAGE WALL (SEE DETAIL 1/A-2) PROPOSED PCS RRH MOUNTED ON UNISTRUT TO PARKING GARAGE WALL (SEE DETAIL 2/A-2) PROPOSED EQUIPMENT CABINET MOUNTED TO PARKING GARGAE WALL (SEE DETAIL 1/C-5) PROPOSED POWER PANEL MOUNTED TO PARKING GARAGE WALL GRADE 0'-0" AGL GRADE 0'-0" AGL TOP OF ROOF 40'-0" AGL 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) NORTH ELEVATIONS 8 C-3 (SHROUD TO MATCH EXISTING DOWN SPOUTS) PROPOSED QUASI-OMNI ANTENNA MOUNTED ON CUSTOM NON-PENETRATING PEAK MOUNT (SEE DETAIL 2/A-1) PROPOSED CUSTOM NON-PENETRATING PEAK ROOF MOUNT (SEE SHEETS ST-1 THROUGH ST-5 FOR MORE DETAIL) WEST ELEVATIONS 7 C-2 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 C-3 PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT (SEE DETAIL 1/C-6) PROPOSED 5' WIDE ACCESS AND UTILITY EASEMENT PROPOSED SHROUDED CABLE TRAY (SHROUD TO MATCH EXISTING DOWN SPOUTS) PROPOSED COAX ROUTED ALONG EXTERIOR OF BUILDING TO SHROUDED CABLE TRAY (SHROUD TO MATCH EXISTING DOWN SPOUTS) EXISTING ROOF ACCESS LADDER PROPOSED ELECTRICAL FROM EXISTING ELECTRICAL PANEL(H1A) IN GARAGE TO NEW EQUIPMENT (ROUTE THROUGH DROP CEILING) (SEE DETAILS SHEET E-1) PROPOSED PCS RRH MOUNTED ON UNISTRUT TO PARKING GARAGE WALL (SEE DETAIL 2/A-2) REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs EQUIPMENT PLAN C-1 6 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 EXISTING UNDERGROUND GAS LINE SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 30 0 15 30 60 120 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) Z-2 (TYP) EXISTING SIDEWALK PROPOSED VERIZON EQUIPMENT MOUNTED ON PARKING GARAGE WALL PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE (SEE SHEET C-4 FOR MORE DETAIL) PROPOSED QUASI-OMNI ANTENNA MOUNTED ON PROPOSED NON-PENETRATING PEAK MOUNT (SEE SHEET A-1 FOR MORE DETAIL) PROPOSED COAX ROUTED ALONG EXTERIOR OF BUILDING TO SHROUDED CABLE TRAY (SHROUD TO MATCH EXISTING DOWN SPOUTS) S COLLEGE AVE EXISTING FIBER LINE PROPOSED TRAFFIC RATED 2'-0"x3'-0" FIBER VAULT (SEE DETAIL 2/C-6) PROPOSED 5'-0" WIDE ACCESS AND UTILITY EASEMENT PROPOSED 5'-0"x10'-0" VERIZON LEASE AREA (SEE DETAIL 2/Z-2) 2 C-2 1 C-2 NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. EXISTING TREE (TYP) PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT (SEE DETAIL 1/C-5) REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 30 0 15 30 60 120 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEC PULL BOX SD SD SD SD SD E E E UE UE UE OT OT OT EV D O O O U/G U/G OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING SKYLIGHT HVAC UNIT AC SECURITY CAMERA VENT PIPE VP BOLLARD COMM DISH GROUNDING NOTES: 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. 2. ALL GROUNDING DEVICES SHALL BE U.L. APPROVED OR LISTED FOR THEIR INTENDED USE. 3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE. 4. GROUND WIRES SHALL BE #2 AWG BARE SOLID COPPER UNLESS NOTED OTHERWISE. 5. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC ("CADWELDS") TO GROUND RODS, GROUND RING WIRE, AND FENCE POSTS UNLESS NOTED OTHERWISE. CLEAN SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED TO GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZED PAINT. 6. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO-HOLE BRASS MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING SCREW SET.) CLEAN GROUND BAR TO SHINY METAL AFTER MECHANICAL CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING. 7. GROUND CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING KITS. 8. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 8" RADIUS. 9. PRIOR TO INSTALLING LUGS ON GROUND WIRES, APPLY THOMAS & BETTS KOPR-SHIELD (TM OF JET LUBE, INC.) PRIOR TO BOLTING GROUND WIRE LUGS TO GROUND BARS, APPLY KOPR-SHIELD OR EQUAL. 10. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY REMOVING ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING CONNECTION, APPLY APPROPRIATE ANTI-OXIDIZATION PAINT. REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs PROJECT DESCRIPTION 1. INSTALL (2) RRHS, (1) POWER PANEL, AND (1) EQUIPMENT CABINET ON WALL IN THE LOWER PARKING STRUCTURE. 2. INSTALL NEW CUSTOM NON-PENETRATING PEAK ROOF MOUNT WITH A QUASI-OMNI ANTENNA WITHIN A FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE. 3. INSTALL UNDERGROUND FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE. 4. INSTALL NEW COAX CABLE FROM THE EQUIPMENT CABINET THROUGH THE DROP CEILING, UP AN EXTERIOR CONDUIT PAINTED TO MATCH THE BUILDING'S EXTERIOR TO THE PROPOSED ROOF EQUIPMENT. 5. RUN NEW ELECTRICAL FROM THE EXISTING POWER PANEL IN THE PARKING STRUCTURE TO THE PROPOSED POWER PANEL AND EQUIPMENT BOX. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FORT COLLINS ZONING: COMMUNITY COMMERCIAL DISTRICT APN: 9713219004 PARCEL SIZE: 14,000 S.F. ELEVATION: 4995' (NAVD 88) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 40'-0"± AGL ANTENNA RAD CENTER: 44'-9" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: BRANDON KISER 9656 S. PROSPERITY RD WEST JORDAN, UT 84088 PH: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV 0 DATE 01-24-18 BY RPH PRELIM CDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 22 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: DANIEL F RECKERT, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52731 (EXP. 10/31/2019) 1 03-27-18 LCW 100% CDs LEGAL DESCRIPTION THE SOUTH 1/2 OF LOT 3; AND ALL OF LOT 4; IN BLOCK 127, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO C-3 PH-1 ST-1 ST-2 ST-3 C-4 ST-4 GN-1 VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 GENERAL NOTES PHOTOSIMULATION VIEWS SITE PLAN (ROOF LEVEL) EQUIPMENT PLAN PROPOSED WEST ELEVATIONS PROPOSED NORTH ELEVATIONS FAUX CHIMNEY DETAILS C-5 CONSTRUCTION DETAILS A-1 A-2 E-3 G-1 G-2 CUSTOM MOUNT ELEVATION CUSTOM MOUNT BALLAST TRAY CUSTOM MOUNT ELEVATION DETAILS STRUCTURAL NOTES ANTENNA SCHEDULE & MOUNTING PLAN OVP & REMOTE RADIO HEAD DETAILS GROUNDING PLAN GROUNDING DETAILS LOAD STUDY Z-2 SITE PLAN (GARAGE) C-6 CONSTRUCTION DETAILS (CONTINUED) E-2 LOAD STUDY E-1 ONE LINE DIAGRAM & PANEL SCHEDULE PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION