Loading...
HomeMy WebLinkAboutFTC MUGS COFFEE SC, WTE (VERIZON) - PDP - PDP170031 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSITEM NO 2 of 3 MEETING DATE January 24, 2018 STAFF Kai Kleer ADMINISTRATIVE HEARING OFFICER Planning Services 281 N College Ave – PO Box 580 – Fort Collins, CO 80522-0580 fcgov.com/developmentreview/ 970.221.6750 STAFF REPORT PROJECT: FTC Mugs Coffee SC, PDP170031 APPLICANT: LRK Consulting Ryan Sagar 1196 Grant Street Suite 313 Denver, CO 80203 OWNER: Venturepro LLLP 706 S College Avenue Fort Collins, CO 80524 PROJECT DESCRIPTION: This is a request for a Project Development Plan (PDP) to install wireless telecommunication equipment concealed within an eight-foot, 11-inch faux chimney on an existing three-story building. The site is located at 706 South College Avenue in the Community Commercial (C-C) zone district. The use is permitted in the zone district, subject to approval by a Hearing Officer. RECOMMENDATION: Staff recommends approval of the FTC Mugs Coffee SC Wireless Telecommunication Equipment, PDP170031. EXECUTIVE SUMMARY: Staff finds the proposed FTC Mugs Coffee SC Project Development Plan complies with the applicable requirements of the City of Fort Collins Land Use Code (LUC), more specifically: • The Project Development Plan complies with process located in Division 2.2 – Common Development Review Procedures for Development Applications of Article 2 – Administration. • The Project Development Plan complies with relevant standards of Article 3 – General Development Standards. Staff Report – FTC Mugs Coffee SC, PDP170031 Administrative Hearing 1-24-2018 Page 2 • The Project Development Plan complies with relevant standards located in Division 4.18 – Community Commercial (C-C) of Article 4 – Districts. Staff Report – FTC Mugs Coffee SC, PDP170031 Administrative Hearing 1-24-2018 Page 3 VICINITY MAP Staff Report – FTC Mugs Coffee SC, PDP170031 Administrative Hearing 1-24-2018 Page 4 COMMENTS: 1. Background The surrounding zoning and land uses to each side of the project site are as follows: Direction Zone District Existing Land Uses North Community Commercial District (C-C) Retail Establishment (One Love Fort Collins), Bar (The R Bar and Lounge), Restaurant (Thai Pepper), South Community Commercial District (C-C) Offices (Alpine Dental Health) East Neighborhood Conservation Buffer (NCB) Multi-Family residential (Remington Row) West CSU Colorado State University Main Campus (Spruce Hall, Rout Hall) The site is located within Block 127 of the Original Town Site Plat on Lot 4. The Plat was established and incorporated on February 3, 1873. Currently, the site contains a three- story mixed-use building built in 2003. The building comprises retail stores, offices, seven residential units and a parking garage. A zoning map is presented on the following page. Staff Report – FTC Mugs Coffee SC, PDP170031 Administrative Hearing 1-24-2018 Page 5 Map 1: FTC Mugs Coffee SC, Zoning Map Staff Report – FTC Mugs Coffee SC, PDP170031 Administrative Hearing 1-24-2018 Page 6 2. Compliance with Article 4 of the Land Use Code – Community Commercial zone district: The project complies with all applicable Article 4 standards as follows: A. Section 4.18(B)(2)(E) – Permitted Uses Wireless telecommunication equipment is a permitted use in the Community Commercial zone district subject to Administrative (Type 1) review. The project proposes the installation of an eight-foot 11-inch faux chimney that contains a single wireless telecommunication antenna. 3. Compliance with Article 3 of the Land Use Code – General Development Standards: Article 3 includes additional standards specific to wireless telecommunication facilities and equipment. Compliance with these standards is described in detail below: A. Section 3.8.13 – Wireless Telecommunication 3.8.13(B) – Co-location To reduce the impact of multiple carriers siting wireless telecommunication equipment in more than one location, no facility or equipment owner or lessee or employee thereof shall act to exclude or attempt to exclude any other wireless telecommunication provider from using the same building, structure or location. The proposed plan contains notes indicating that owners and employees shall cooperate to achieve future co-location efforts. 3.8.13(C)(3) – Wireless Telecommunication Equipment Wireless telecommunication equipment must be of the same color as the building or structure to which or on which such equipment is mounted. The proposed project mounts all equipment accessory to the antenna within the parking garage. Notes have been added so that the visible conduit is painted to match the building’s exterior color. Whenever a wireless telecommunication antenna is attached to a building roof, the height of the antenna must not be more than fifteen (15) feet over the height of the building. Staff Report – FTC Mugs Coffee SC, PDP170031 Administrative Hearing 1-24-2018 Page 7 The proposed height of the faux chimney is eight-feet 11-inches over the height of the building. The proposal therefore does not exceed the maximum height limit of 15 feet. All wireless telecommunication equipment must be located as far from the edge of the roof as possible. Even if the building is constructed at or above the building height limitations contained in Section 3.8.17, the additional fifteen (15) feet is permissible. The applicant proposes an eight-foot 11-inch faux chimney with a 39-foot setback from the front of the building. The applicant asserts that the proposed location is the best way to limit the impact of the concealment while also keeping in context with other typical rooftop elements found throughout the area. Whenever wireless telecommunication equipment is mounted to the wall of a building or structure, the equipment must be mounted in a configuration as flush to the wall as technically possible and must not project above the wall on which it is mounted. Such equipment must, to the maximum extent feasible, also feature the smallest and most discreet components that the technology will allow so as to have the least possible impact on the architectural character and overall aesthetics of the building or structure. Roof and ground-mounted wireless telecommunication equipment must be screened by parapet walls or screen walls in a manner compatible with the building’s design, color and material. The proposed project conceals all associated wireless equipment accessory to the antenna within a first-floor parking garage. The wireless antenna is concealed within the faux chimney and features a painted and textured brick design consistent with the buildings brick façade. 3.8.13(C)(8) – Color Telecommunication equipment must be painted to match as closely as possible the color and texture of the wall, building or surrounding built environment. Muted colors, earth tones and subdued colors must be used. Notes for all items associated with this proposal and within public view have been added to the plan to ensure that colors match the existing building. 4. Findings of Fact/Conclusion: Staff Report – FTC Mugs Coffee SC, PDP170031 Administrative Hearing 1-24-2018 Page 8 In evaluating the request for the FTC Mugs Coffee SC, Wireless Telecommunication Equipment Project Development Plan, staff makes the following findings of fact: A. The FTC Mugs Coffee SC – Wireless Telecommunication Equipment Project Development Plan complies with the process located in Division 2.2 – Common Development Review Procedures for Development Applications of Article 2 – Administration. B. The FTC Mugs Coffee SC – Wireless Telecommunication Equipment Project Development Plan complies with the applicable standards located in Article 3 – General Development Standards. C. The FTC Mugs Coffee SC – Wireless Telecommunication Equipment Project Development Plan complies with the applicable standards in Division 4.18, Community Commercial (C-C) of Article 4 – Districts. RECOMMENDATION: Staff recommends approval of the FTC Mugs Coffee SC – Wireless Telecommunication Equipment Project Development Plan, PDP170031. ATTACHMENTS: 1. Applicant’s Statement of Planning Objectives 2. FTC Mugs Coffee SC Plan Set a. Title Sheet b. Photosimulation Views c. Site Plan d. Equipment Plan e. Elevations f. Line of Site Elevations LRK CONSULTING ON BEHALF OF VERIZON WIRELESS August 16, 2017 Wireless-Telecommunications Equipment (Co-location) Review: Planning Objective FTC Mugs Coffee SC located at 706 S College Ave, Parcel ID# 9713219002 My client, Verizon Wireless, wishes to submit an application for Wireless-Telecommunications Equipment that will be located on top of a three-story building along College Avenue and the east side of Colorado State University. The installation of this new equipment will provide critical 4G-LTE voice and data services to a location with increasingly higher pedestrian and vehicular traffic providing an immediate benefit to the traveling public, emergency services, residents, employees, and customers who shop at the nearby commercial developments. Specifically, my client proposes the installation of the following equipment: • An antenna located inside a new square chimney structure. The total height of the new chimney is 8’-11” above the existing roof height and shall be painted to match the primary color of the building. • Telecommunications equipment including Remote Radio Heads (RRHs), Over-Voltage Protection Units (OVPs), and a radio cabinet wall-mounted inside the first floor of the existing parking garage. The RRHs are meant to limit line loss to the radio equipment, while the OVP is installed to protect the equipment from electrical surges. • An underground fiber optic cable vault located near the east property line. • Underground cabling from utility sources to the proposed wall-mounted ground equipment. • Cabling from the new ground level equipment to the proposed antenna located within a new shroud designed to match the existing downspouts. In accordance with the Communications and Technology section of the City Comprehensive Plan, this new wireless equipment will provide citizens access to high-quality, reliable wireless service in a part of the city that faces significant coverage and capacity demands. Access to this improved service will continue to be a critical component for community interactions as well as economic growth now that 4G-LTE has become widely utilized and as the nation begins to transition into 5G capabilities. Furthermore, this design carefully took into consideration and meets the standards as outlined in Paragraph C Standards of Chapter 3.8.13 of the Municipal Code specifically relating to not exceeding the height allowance, using the smallest and most discreet components that technology will allow, and proposing screening of the antenna through the installation of a chimney structure that promotes a stealth design. Please let me know if there is anything else I can provide you with to aid in the review of this project. I look forward to working with your department as Verizon Wireless continues to invest in reliable, fast, and strong wireless services in the City of Fort Collins. Sincerely, Senior Site Acquisition Consultant, LRK Consulting LLC 1196 Grant Street, Unit 313, Denver, CO 80203 mrsagar45@gmail.com 219-477-0099 FTC MUGS COFFEE SC 714 S COLLEGE AVE FT. COLLINS, COLORADO 80524 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: MERGE ONTO I-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W TOWARD DENVER. KEEP RIGHT AT THE FORK TO CONTINUE ON I-270 W, FOLLOW SIGNS FOR FORT COLLINS/BOULDER. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARD FT COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W, TURN LEFT ONTO S COLLEGE AVE, CONTINUE SOUTH ON COLLEGE AVE PAST LAUREL STREET, THE SITE AND PARKING ENTRANCE WILL BE ON THE LEFT. FT. COLLINS, COLORADO CLIENT PROPERTY OWNER JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PHONE: 913-344-2030 VENTUREPRO LLLP, ROBIN & CHRISTIAN BACHELET CONTACT: ROBIN BACHELET PHONE: 970-566-2586 EMAIL: RBACHELET@MAC.COM VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: Ram.Nandiraju@verizonwireless.com RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED PHOTOSIMULATION VIEWS PH-1 2 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING EAST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST) N.T.S. EM EM EM ET ET VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP N 1 Z-1 SITE PLAN SCALE: 1"=30'-0" REVISION SCHEDULE REV A DATE 06-19-17 BY EM EM VP VP VP VP VP VP VP VP 1'-6" EM EM EM ET ET 10'-0" 5'-0" GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 8. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH 39'-5" 44'-9" 48'-4" 39'-5" REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED ELEVATIONS Z-3 5 PROPOSED QUASI-OMNI ANTENNA WITHIN FAUX CHIMNEY NOTE: FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE. 2 Z-3 ELEVATION SCALE: 1/16" = 1'-0" PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S FACADE PROPOSED CUSTOM NON-PENETRATING PEAK MOUNT PROPOSED VERIZON RAD CENTER 44'-9" AGL TOP OF ROOF 39'-5" AGL TOP OF PROPOSED SHROUD 48'-4" AGL 1 Z-3 130'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-4 PROPOSED LINE OF SIGHT SCALE: N.T.S. REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED LINE OF SIGHT Z-4 6 S COLLEGE AVE EXISTING BUILDING'S CROSS SECTION EXISTING SIDEWALK EXISTING CURB PROPOSED LINE OF SIGHT FROM 5'8" IN THE MIDDLE OF THE SIDEWALK ACROSS S COLLEGE AVE EXISTING CURB PROPOSED QUASI-OMNI ANTENNA WITHIN CONCEALING SHROUD PROPOSED FAUX CHIMNEY PAINTED REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED FAUX CHIMNEY DETAIL Z-5 7 1 Z-5 FAUX CHIMNEY DETAILS SCALE: 1/2"=1'-0" 1 0 0.5 1 2 4 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) TOP OF EXISTING ROOF PROPOSED ANTENNA MOUNTING PIPE (TYP) PROPOSED QUASI OMNI ANTENNA WITHIN CHIMNEY CONCEALMENT SHROUD PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH SPARK ARRESTOR (SHROUD TO BE PAINTED AND TEXTURED TO MATCH BUILDING) PROPOSED SPARK ARRESTOR (FINAL DESIGN TBD) RF TRANSPARENT MATERIAL SPECIFICATIONS FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES: 1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES. 2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING. 1'-8" 4" 2 1/8" 2 1/4" 1 1/2" 7'-2 7/8" 9 1/4" TOP OF PEAK 39'-5" 6" 3" RAD CENTER 44'-9" 1'-5" 1'-8" 1 1/2" TYP. 1 1/2" TYP. 1" TYP. 3" 1 1/4" 1 1/4" 2 1/4" 1 1/2" 1'-5" 1 ST-1 CUSTOM SHROUD (ELEVATION) N.T.S. PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED 1/2" A325 THRU BOLT (TYP OF 8) PROPOSED L4x4x1/4 FRP TOP ANGLE, THRU BOLT TO FRP TUBE (TYP OF 4) PROPOSED 1/2" U-BOLT (TYP OF 2) PROPOSED 2'-4" LONG 2.0" STD MOUNTING PIPE PROPOSED L6x3.5x5/16 COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE (REF 2/ST-3) CUSTOM MOUNT ELEVATION ST-1 NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. PROPOSED 3"x6" WELDED PLATE WITH SLOTTED HOLES 2 3'-10" 1'-8" 8 1/2" TYP. 3" TYP. 8'-0" 3'-1 11/16" 3'-1 11/16" 1" 1 1/4" 1 1/4" 3'-10" 1 ST-2 CUSTOM BALLAST TRAY (PLAN) N.T.S. CUSTOM MOUNT BALLAST TRAY ST-2 PROPOSED 2"X3" SPACER PLATE (TYP. OF 2) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 1/2" A325 BOLT ST-2 2 ST-2 3 NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 6" 3 1/2" 5 1/2" 5" 2" 6" 2 1/8" 2 1/16" 1 3/4" 2 3/16" 13/16" 5'-3 3/8" 3 1/2" 3'-5 3/8" 2 ST-3 FRP COLUMN CONNECTION N.T.S. 1 ST-3 PEAK CONNECTION DETAIL N.T.S. 4 ST-3 3D Rendering N.T.S. PROPOSED 1/2" A325 THRU BOLT (TYP. 2 PER CONNECTION) PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) CUSTOM MOUNT ELEVATION DETAILS ST-3 3 ST-3 BALLAST TO FRAME CONNECTION N.T.S. NOTE: RF TRANSPARENT PANELS TO BE ATTACHED TO OUTSIDE OF VERTICAL FRAME AND PAINTED TO MATCH BUILDING. PANEL CONNECTIONS TO BE DESIGNED BY MANUFACTURER. MANUFACTURER TO PROVIDE ACCESS PANEL BEHIND ANTENNA MOUNT LOCATION. REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 STRUCTURAL NOTES ST-4 STRUCTURAL NOTES: 1. DESIGN INFORMATION AND GENERAL REQUIREMENTS 1.1 CODES a. DESIGN CONFORMS TO 2015 INTERNATIONAL BUILDING CODE. b. ASCE 7-10 MIN. DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES. c. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, ANSI/AISC 360-10. 1.2 MISCELLANEOUS a. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. 2. STRUCTURAL STEEL 2.1 MATERIALS a. STRUCTURAL STEEL. . . . . . . . ASTM A992 CHANNEL . . . . . . . . . . . . . . . . . . .ASTM A36 ANGLES, PLATE & MISC. . . . . . ASTM A36 RECTANGULAR HSS . . . . . . . . . ASTM A500, GRADE B, Fy=46 ksi ROUND HSS . . . . . . . . . . . . . . . . ASTM A500, GRADE B, Fy=42 ksi PIPES . . . . . . . . . . . . . . . . . . . . . ASTM A53, GRADE B b. BOLTS . . . . . . . . . . . . . . . . . . . . ASTM A325 U.N.O. c. WELDING ELECTRODES . . . . . . . . AWS A5.1 (E70XX) d. STEEL CONSTRUCTION SHALL CONFORM TO "SPECIFICATION FOR STRUCTURAL STEEL FOR BUILDINGS - 14TH EDITION". e. WELDING SHALL CONFORM TO AWS D1.1 "STRUCTURAL WELDING CODE". f. THE FABRICATOR SHALL FURNISH CHECKED SHOP AND ERECTION DRAWINGS TO THE ENGINEER, AND OBTAIN APPROVAL PRIOR TO FABRICATING ANY STRUCTURAL STEEL. SHOP DRAWINGS SHALL CONFORM TO AISC "DETAILING FOR STEEL CONSTRUCTION". 2.2 CONNECTIONS a. SHOP CONNECTIONS MAY BE BOLTED OR WELDED. b. FIELD CONNECTIONS SHALL BE BOLTED WITH A325-N BOLTS, (INSTALLED SNUG TIGHT) UNLESS OTHERWISE SPECIFIED OR IF WELDED CONNECTIONS ARE NOTED ON DRAWINGS. c. FIELD CONNECTIONS SHALL BE MADE WITH HIGH TENSILE BOLTS AND HARDENED WASHERS EXCEPT AS INDICATED ON THE DESIGN DRAWINGS. d. CONNECTIONS NOT SHOWN ON DRAWINGS SHALL BE DESIGNED BY THE STEEL FABRICATOR. CONNECTIONS SHALL BE DESIGNED IN ACCORDANCE WITH AISC "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" AND AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". e. DO NOT FIELD CUT OR ALTER STRUCTURAL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL OF ENGINEER. 2.3 FINISHES a. STRUCTURAL STEEL SHALL BE HOT DIP GALVANIZED AFTER FABRICATION PER ASTM A123 b. ALL STEEL SHALL BE CLEANED OF RUST, LOOSE MILL SCALE AND OTHER FOREIGN MATERIALS AND BE HOT DIPPED GALVANIZED OR STAINLESS STEEL IF OTHERWISE INDICATED ON PLAN. c. FIELD FABRICATIONS SHALL BE TREATED WITH ZRC COLD GALVANIZING COMPOUND OR EQUAL PRIOR TO ASSEMBLY. d. BOLTS AND NUTS SHALL BE HOT DIP GALVANIZED PER ASTM A153. 3.1 MATERIALS a. USE STRONGWELL EXTREN FIBERGLASS STRUCTURES SERIES 625 TUBES AND ANGLES UNLESS OTHERWISE NOTED. b. FRP PANELS ARE TO BE UV RESISTANT FOR EXTERIOR EXPOSURE AND MUST BE RF TRANSPARENT TO ALLOW UNIMPEDED ANTENNA/MICROWAVE DISH SIGNAL PROPAGATION. c. ATTACH PANEL ACCORDING TO MANUFACTURERS RECOMMENDATIONS. d. FRP MATERIALS ARE TO BE CONSTRUCTED TO MEET ALL OF THE MANUFACTURERS REQUIREMENTS. e. DO NOT ALTER STRUCTURAL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL OF ENGINEER OF RECORD. f. FRP MEMBERS MAY BE SAWED, DRILLED, ROUTED, AND TURNED ON A LATHE OR OTHER MACHINE TOOL. PUNCHING SHALL NOT BE PERMITTED. CARBIDE OR DIAMOND TIPPED TOOLS ARE RECOMMENDED. g. FRP MEMBERS MAY BE FASTENED MECHANICALLY USING SCREWS, BOLTS, OR RIVETS. FIBERBOLT FIBERGLASS STUDS AND HEX HEADS SHOULD BE USED ONLY WHERE SPECIFICALLY SHOWN IN THE DESIGN DRAWINGS. h. FRP MEMBERS MAY BE CONNECTED WITH ADHESIVE ONLY IF USED IN CONJUNCTION WITH THE SPECIFIED MECHANICAL FASTENERS. 3. FIBER REINFORCED POLYMER REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED FRONT SIDE PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE PROPOSED 5"x1/4" SPACER PLATE (ONE SIDE) (TYP. OF 2) PROPOSED 6"x1/4" WELDED CONNECTION PLATE (TYP. OF 4) NOTE: CONNECTION BOLTS NOT SHOWN FOR CLARITY. SEE FRONT DETAIL PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE PROPOSED 5"x1/4" SPACER PLATE (ONE SIDE) (TYP. OF 2) PROPOSED 6"x1/4" WELDED CONNECTION PLATE (TYP. OF 4) PROPOSED 1/2" A325 CONNECTION BOLT IN SLOTTED HOLES (TYP.) PROPOSED 1/2" A325 SET BOLT FIELD DRILL FOR ROOF SLOPE PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE PROPOSED L6"x3.5"x5/16" BRACE ANGLE WELDED TO COLUMN SUPPORT ANGLES PROPOSED L3x3x3/16" CLIP ANGLES WELDED TO BALLAST TRAY PROPOSED L3x3x3/16"BALLAST ANGLE 10 1/8 1/8 TYP 1/8 1/8 TYP 1/8 1/8 TYP PROPOSED L6"x3.5"x5/16" COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE EXISTING ROOF PEAK LINE NOTE: SHROUD AND RELATED MEMBERS ARE NOT SHOWN FOR CLARITY (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED 2 ST-2 BALLAST TRAY DETAIL (NEAR SHROUD) N.T.S. 3 ST-2 BALLAST TRAY DETAIL (AWAY FROM SHROUD) N.T.S. 4 ST-2 4 ST-2 BALLAST TRAY DETAIL (SIDE N.T.S. PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT COPE ANGLES AND WELD (ALL CORNERS) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 1/2" A325 BOLT (TYP.) PROPOSED L3x3x3/16 VERTICAL BALLAST ANGLE PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT COPE ANGLES AND WELD (ALL CORNERS) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED CMU BALLAST PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT PROPOSED 2"X3" SPACER PLATE (TYP. OF 2) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 1/2" A325 BOLT (TYP.) PROPOSED L3x3x3/16 VERTICAL BALLAST ANGLE PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT PROPOSED L3x3x3/16 BALLAST ANGLE ST-3 3 PROPOSED 2"X3" SPACER PLATE (TYP. OF 2) PROPOSED L3x3x3/16 BALLAST ANGLE (TYP.) PROPOSED 1/2" A325 BOLT (TYP.) PROPOSED 3"1/4" BALLAST BRACE 3'-9 1/2" LONG. FIELD CUT CORNERS AS REQUIRED FOR FIT COPE ANGLES AND WELD (ALL CORNERS) PROPOSED L3x3x3/16 BALLAST ANGLE PROPOSED 1/2" A325 BOLT (TYP.) PROPOSED L6x3.5x5/16 ANGLE WELDED TO BALLAST TRAY 9 CJP 1/8 CJP ST-1 3 ST-1 3 ST-1 CUSTOM SHROUD MOUNT DETAIL N.T.S. 2 ST-1 CUSTOM SHROUD TOP DETAIL N.T.S. 3 ST-1 1 2 ST-3 ST-3 PROPOSED L6x3.5x5/16 COLUMN SUPPORT ANGLES THRU BOLTED TO FRP TUBE (REF 2/ST-3) PROPOSED 1/2" A325 THRU BOLT (TYP OF 8) PROPOSED L4x4x1/4 FRP TOP ANGLE, THRU BOLT TO FRP TUBE (TYP OF 4) PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) TOP SIDE PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED FRP 3"x3"x1/4" TUBE (TYP OF 4) PROPOSED L3x3x3/16 COLUMN SUPPORT ANGLE (TYP OF 4) PROPOSED 1/2" U-BOLT (TYP OF 2) PROPOSED 2'-4" LONG 2.0" STD MOUNTING PIPE PROPOSED 1/2" U-BOLT (TYP OF 2) PROPOSED 2'-4" LONG 2.0" STD MOUNTING PIPE PROPOSED 1/2" A325 THRU BOLT (TYP OF 8) PROPOSED 1/2" A325 THRU BOLT PROPOSED 1/2" A325 BOLT PROPOSED L3x3x3/16 COLUMN SUPPORT ANGLE (TYP OF 4) PROPOSED L6x3.5x5/16" MOUNT ANGLE (TYP OF 1) REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED 8 PROPOSED L6x3.5x5/16 BRACING ANGLES WELDED TO FRP TUBE (REF 2/ST-3) 3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL. 4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPE. 5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION. 6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN DRAWINGS. 7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS FOLLOWS: 1/2" DIAMETER NUTS 8 FT-LBS TORQUE 5/8" DIAMETER NUTS 16 FT-LBS TORQUE 3/4" DIAMETER NUTS 24 FT-LBS TORQUE FIBERGLASS PANEL NOTES: BY LARSON CAMOFLAGE, LLC - FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN. - PANELS TO BE MINIMUM 1/4" THICKNESS. 1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF TRANSPARENT MATERIALS. 2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED APPEARANCE. 3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT. 4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT. 5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS: STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS. 6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE ULTRAVIOLET PROTECTION. 7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN. 8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS. 9. CONTACT KEN PUEHL FOR ADDITIONAL INFORMATION AT 520-741-3115. & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE PROPOSED CUSTOM NON-PENETRATING PEAK MOUNT ELEVATION SCALE: 1/16" = 1'-0" TOP OF ROOF 39'-5" AGL PROPOSED COAX ROUTED IN CONDUIT WITH SHROUD TO MATCH EXISTING DOWNSPOUT 8 0 4 8 16 32 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 8 0 4 8 16 32 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. A SECTOR CABLE TABLE N/A AZIMUTH 80'-0" LENGTH 2 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 7/8" COAX REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED EQUIPMENT PLAN Z-2 4 N PROPOSED EQUIPMENT CABINET MOUNTED ON EXISTING WALL PROPOSED POWER PANEL MOUNTED ON EXISTING WALL PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE (2) PROPOSED RRH'S AND DIPLEXERS MOUNTED ON EXISTING WALL PROPOSED QUASI-OMNI ANTENNA MOUNTED ON PROPOSED NON-PENETRATING PEAK MOUNT PROPOSED COAX RUN THROUGH DROP CEILING TO EXTERIOR PROPOSED COAX RUN THROUGH CONCEALED EXTERIOR CONDUIT PAINTED TO MATCH BUILDING'S EXTERIOR EXISTING POWER PANEL PROPOSED NON-PENETRATING PEAK ROOF MOUNT INSTALL CHECK METER TO PROPOSED ELECTRICAL RUN 1 Z-2 EQUIPMENT PLAN UPPER LEVEL DETAIL SCALE: 1/16"=1'-0" 2 Z-2 EQUIPMENT PLAN GROUND LEVEL DETAIL SCALE: 1/16"=1'-0" PROPOSED FIBER VAULT PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED ELECTRICAL LINE TO EXISTING POWER PANEL 1 Z-4 2 Z-3 8 0 4 8 16 32 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 8 0 4 8 16 32 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED SITE PLAN Z-1 3 EXISTING CURB (TYP) EXISTING SIDEWALK LEGEND W SS F GAS GAS OE UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD E UE OT EV D O O U/G OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET PROPOSED EQUIPMENT CABINET MOUNTED ON EXISTING WALL PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE (2) PROPOSED RRH'S MOUNTED ON EXISTING WALL PROPOSED QUASI-OMNI ANTENNA MOUNTED ON PROPOSED NON-PENETRATING PEAK MOUNT (SEE ELEVATION 2/Z-3) PROPOSED COAX RUN TO PROPOSED ROOF EQUIPMENT EXISTING POWER PANEL S COLLEGE AVE EXISTING FIBER LINE PROPOSED FIBER VAULT PROPOSED 5' WIDE ACCESS AND UTILITY EASEMENT PROPOSED 5'x10' VERIZON LEASE AREA (SEE DETAIL 2/Z-2) EXISTING 6' WIDE ELECTRICAL EASEMENT VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING 2 Z-3 1 Z-4 NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. 15 0 7.5 15 30 60 1 inch = 30 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 EQUIPMENT PLAN Z-3 ELEVATIONS PROJECT DESCRIPTION 1. INSTALL: (2) RRHS, (1) POWER PANEL, AND (1) EQUIPMENT CABINET MOUNTED TO THE WALL IN THE LOWER PARKING STRUCTURE. 2. INSTALL NEW CUSTOM NON-PENETRATING PEAK ROOF MOUNT WITH A QUASI-OMNI ANTENNA WITHIN A FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE. 3. INSTALL UNDERGROUND FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE. 4. INSTALL NEW COAX CABLE FROM THE EQUIPMENT CABINET THROUGH THE DROP CEILING, UP AN EXTERIOR CONDUIT PAINTED TO MATCH THE BUILDING'S EXTERIOR TO THE PROPOSED ROOF EQUIPMENT. 5. RUN NEW ELECTRICAL FROM THE EXISTING POWER PANEL IN THE PARKING STRUCTURE TO THE PROPOSED POWER PANEL AND EQUIPMENT BOX. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: COMMUNITY COMMERCIAL DISTRICT APN: 9713219004 PARCEL SIZE: 14,000 S.F. ELEVATION: 4995' (NAVD 88) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 39'-5"± AGL ANTENNA RAD CENTER: 44'-9" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 9-22-17 GAC REVISED D 11-29-17 LCW REVISED E 01-05-18 GAC REVISED LEGAL DESCRIPTION THE SOUTH 1/2 OF LOT 3; AND ALL OF LOT 4; IN BLOCK 127, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Z-4 LINE OF SIGHT PH-1 PHOTOSIMULATION VIEW ST-1 CUSTOM MOUNT ELEVATION ST-2 CUSTOM MOUNT BALLAST TRAY ST-3 CUSTOM MOUNT ELEVATION DETAILS ST-4 STRUCTURAL NOTES Z-5 FAUX CHIMNEY DETAIL