HomeMy WebLinkAboutFTC MUGS COFFEE SC, WTE (VERIZON) - PDP - PDP170031 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC MUGS COFFEE SC
714 S COLLEGE AVE
FT. COLLINS, COLORADO 80524
SMALL CELL
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
DEPART 3131 S VAUGHN WAY, AURORA, CO 80014:
MERGE ONTO I-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W TOWARD DENVER. KEEP RIGHT AT
THE FORK TO CONTINUE ON I-270 W, FOLLOW SIGNS FOR FORT COLLINS/BOULDER. TAKE EXIT 0
TO MERGE ONTO I-25 N TOWARD FT COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W, TURN
LEFT ONTO S COLLEGE AVE, CONTINUE SOUTH ON COLLEGE AVE PAST LAUREL STREET, THE SITE
AND PARKING ENTRANCE WILL BE ON THE LEFT.
FT. COLLINS, COLORADO
CLIENT
PROPERTY OWNER
JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 66211
PHONE: 913-344-2030
VENTUREPRO LLLP, ROBIN & CHRISTIAN BACHELET
CONTACT: ROBIN BACHELET
PHONE: 970-566-2586
EMAIL: RBACHELET@MAC.COM
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JASON SHELLEDY
PHONE: 970-646-1283
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
1196 GRANT ST. UNIT 313
DENVER, CO 80203
CONTACT: RYAN SAGAR
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: Ram.Nandiraju@verizonwireless.com
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2015 (W/ LOCAL AMENDMENTS)
NEC 2017
NFPA-1 (2006)
U - UTILITY
IIB
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
REVISION SCHEDULE
REV
A
DATE
06-19-17
BY
EGW PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0099
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 07-10-17 KRC FINAL ZONING
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
C 09-22-17 GAC REVISED
PHOTOSIMULATION
VIEWS
PH-1
2
2
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING EAST)
N.T.S.
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST)
N.T.S.
EM
EM
EM
ET
ET
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
VP VP VP
VP
VP VP
VP
VP VP
VP
VP VP
VP
VP
VP
VP
VP
VP VP
VP
VP
VP
VP
VP
VP
VP
VP
VP
N
1
Z-1
SITE PLAN
SCALE: 1"=30'-0"
REVISION SCHEDULE
REV
A
DATE
06-19-17
BY
VP VP
VP
VP VP
VP
VP VP
3'-0"
3'-0"
EM
EM
EM
ET
ET
10'-0"
5'-0"
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES,
LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR
OTHER PUBLIC AUTHORITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND
INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR
MUNICIPAL AUTHORITIES.
3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING,
OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF
BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID
DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY
FOR THE OVERALL INTENT OF THESE DRAWINGS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING
SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE
CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF
CONSTRUCTION OF THIS FACILITY.
5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL
MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT.
ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID
TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH
THE CONTRACT DOCUMENTS.
7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN
STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE
PROPOSED.
8. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO
HANDICAP ACCESS REQUIRED).
10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR
SANITARY SERVICE.
11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER.
12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF
ENGINEERING PRIOR TO INSTALLATION.
13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015
REQUIREMENTS.
14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL.
15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES
PRIOR TO EXCAVATING.
16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT
AND CONTACT OWNERS REPRESENTATIVE.
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
39'-5"
44'-9"
47'-9"
39'-5"
REVISION SCHEDULE
REV
A
DATE
06-19-17
BY
EGW PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0099
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 07-10-17 KRC FINAL ZONING
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
C 09-22-17 GAC REVISED
ELEVATIONS
Z-3
5
PROPOSED QUASI-OMNI ANTENNA
WITHIN FAUX CHIMNEY
NOTE:
FAUX CHIMNEY PAINTED & TEXTURED TO MATCH
EXISTING BUILDING'S BRICK FACADE.
2
Z-3
ELEVATION
SCALE: 1/16" = 1'-0"
PROPOSED FAUX CHIMNEY PAINTED
& TEXTURED TO MATCH EXISTING
BUILDING'S FACADE
PROPOSED NON-PENETRATING PEAK
MOUNT
PROPOSED VERIZON RAD CENTER
44'-9" AGL
TOP OF ROOF
39'-5" AGL
TOP OF PROPOSED SHROUD
47'-9" AGL
1
Z-3
ELEVATION
SCALE: 1/16" = 1'-0"
130'-0"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
1
Z-4
PROPOSED LINE OF SIGHT
SCALE: N.T.S.
REVISION SCHEDULE
REV
A
DATE
06-19-17
BY
EGW PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0099
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 07-10-17 KRC FINAL ZONING
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
C 09-22-17 GAC REVISED
LINE OF SIGHT
Z-4
6
S COLLEGE AVE
EXISTING BUILDING'S CROSS SECTION
EXISTING SIDEWALK
EXISTING CURB
PROPOSED LINE OF SIGHT FROM 5'8" IN
THE MIDDLE OF THE SIDEWALK
ACROSS S COLLEGE AVE
EXISTING CURB
PROPOSED QUASI-OMNI ANTENNA
WITHIN CONCEALING SHROUD
PROPOSED FAUX CHIMNEY PAINTED
& TEXTURED TO MATCH EXISTING
BUILDING'S BRICK FACADE
PROPOSED NON-PENETRATING
PEAK MOUNT
TOP OF ROOF
39'-5" AGL
PROPOSED COAX ROUTED IN CONDUIT
WITH SHROUD TO MATCH EXISTING
DOWNSPOUT
8 0 4 8 16 32
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
8 0 4 8 16 32
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
A
SECTOR
CABLE TABLE
N/A
AZIMUTH
80'-0"
LENGTH
2
NO. TYPE
NOTES:
1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION
MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING.
2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED
OTHERWISE.
3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY
AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO
INSTALLING ANY ANTENNAS.
SIZE
7/8" COAX
REVISION SCHEDULE
REV
A
DATE
06-19-17
BY
EGW PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0099
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 07-10-17 KRC FINAL ZONING
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
C 09-22-17 GAC REVISED
EQUIPMENT PLAN
Z-2
4
N
PROPOSED EQUIPMENT CABINET
MOUNTED ON EXISTING WALL
PROPOSED POWER PANEL
MOUNTED ON EXISTING WALL
PROPOSED 3'x3'x8'-4" FAUX CHIMNEY
PAINTED & TEXTURED TO MATCH
EXISTING BUILDING'S BRICK FACADE
(2) PROPOSED RRH'S AND
DIPLEXERS MOUNTED ON EXISTING
WALL
PROPOSED QUASI-OMNI ANTENNA
MOUNTED ON PROPOSED
NON-PENETRATING PEAK MOUNT
PROPOSED COAX RUN THROUGH
DROP CEILING TO EXTERIOR
PROPOSED COAX RUN THROUGH
CONCEALED EXTERIOR CONDUIT
PAINTED TO MATCH BUILDING'S
EXTERIOR
EXISTING POWER PANEL
PROPOSED NON-PENETRATING
PEAK ROOF MOUNT
INSTALL CHECK METER TO
PROPOSED ELECTRICAL RUN
1
Z-2
EQUIPMENT PLAN UPPER LEVEL DETAIL
SCALE: 1/16"=1'-0"
2
Z-2
EQUIPMENT PLAN GROUND LEVEL DETAIL
SCALE: 1/16"=1'-0"
PROPOSED FIBER VAULT
PROPOSED FIBER RUN FROM FIBER
VAULT TO EQUIPMENT SITE
PROPOSED ELECTRICAL LINE TO
EXISTING POWER PANEL
1
Z-4
2
Z-3
8 0 4 8 16 32
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
8 0 4 8 16 32
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
EGW PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0099
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 07-10-17 KRC FINAL ZONING
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
C 09-22-17 GAC REVISED
SITE PLAN
Z-1
3
EXISTING
CURB (TYP)
EXISTING
SIDEWALK
LEGEND
W
SS
F
GAS GAS
OE
UT
X X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD
E
UE
OT
EV
D
O O
U/G
OHW
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
PROPOSED EQUIPMENT CABINET
MOUNTED ON EXISTING WALL
PROPOSED FAUX CHIMNEY PAINTED
& TEXTURED TO MATCH EXISTING
BUILDING'S BRICK FACADE
(2) PROPOSED RRH'S MOUNTED ON
EXISTING WALL
PROPOSED QUASI-OMNI ANTENNA
MOUNTED ON PROPOSED
NON-PENETRATING PEAK MOUNT
(SEE ELEVATION 2/Z-3)
PROPOSED COAX RUN TO
PROPOSED ROOF EQUIPMENT
EXISTING POWER PANEL
S COLLEGE AVE
EXISTING FIBER LINE
PROPOSED FIBER VAULT
PROPOSED 5' WIDE ACCESS
AND UTILITY EASEMENT
PROPOSED 5'x10' VERIZON LEASE
AREA
(SEE DETAIL 2/Z-2)
EXISTING 6' WIDE ELECTRICAL EASEMENT
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
2
Z-3
1
Z-4
NOTE:
NO WIRELESS TELECOMMUNICATION FACILITY OR
EQUIPMENT OWNER OR LESSEE OR EMPLOYEE
THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO
EXCLUDE ANY OTHER WIRELESS
TELECOMMUNICATION PROVIDER FROM USING THIS
BUILDING, STRUCTURE OR LOCATION.
15 0 7.5 15 30 60
1 inch = 30 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 EQUIPMENT PLAN
Z-3 ELEVATIONS
PROJECT DESCRIPTION
1. INSTALL: (2) RRHS, (1) POWER PANEL, AND (1) EQUIPMENT CABINET MOUNTED TO THE WALL
IN THE LOWER PARKING STRUCTURE.
2. INSTALL NEW NON-PENETRATING PEAK ROOF MOUNT WITH A QUASI-OMNI ANTENNA WITHIN
A FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE.
3. INSTALL UNDERGROUND FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE.
4. INSTALL NEW COAX CABLE FROM THE EQUIPMENT CABINET THROUGH THE DROP CEILING,
UP AN EXTERIOR CONDUIT PAINTED TO MATCH THE BUILDING'S EXTERIOR TO THE
PROPOSED ROOF EQUIPMENT.
5. RUN NEW ELECTRICAL FROM THE EXISTING POWER PANEL IN THE PARKING STRUCTURE
TO THE PROPOSED POWER PANEL AND EQUIPMENT BOX.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
JURISDICTION: CITY OF FT. COLLINS
ZONING: COMMUNITY COMMERCIAL DISTRICT
APN: 9713219004
PARCEL SIZE: 14,000 S.F.
ELEVATION: 4995' (NAVD 88)
STRUCTURE TYPE: BUILDING
STRUCTURE HEIGHT: 39'-5"± AGL
ANTENNA RAD CENTER: 44'-9" AGL
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 66211
PH: 913-344-2030
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: 720 279-8973
REVISION SCHEDULE
REV
A
DATE
06-19-17
BY
EGW PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0099
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 07-10-17 KRC FINAL ZONING
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
C 09-22-17 GAC REVISED
LEGAL DESCRIPTION
THE SOUTH 1/2 OF LOT 3; AND ALL OF LOT 4; IN BLOCK 127, CITY OF FORT COLLINS, COUNTY OF
LARIMER, STATE OF COLORADO
Z-4 LINE OF SIGHT
PH-1 PHOTOSIMULATION VIEW