HomeMy WebLinkAboutPLATTE RIVER POWER AUTHORITY CAMPUS - FDP - FDP180004 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLAN (3)FINAL PLAN SITE PLAN PLATTE RIVER POWER AUTHORITY 1603 Oakridge Drive Fort Collins, CO 80525 970-223-7577 1 OF 2 FEBRUARY 14, 2018 REVISIONS: DATE: ____________________________ ______________ ____________________________ ______________ ____________________________ ______________ ____________________________ ______________ By: ______________________________________________ Date: __________________________________ COUNTY OF LARIMER ) VICINITY MAP SCALE: N.T.S. LOT 1, PLATTE RIVER POWER AUTHORITY HEADQUARTERS P.U.D. AND LOT 2, COLLINDALE INDUSTRIAL PARK LEGAL DESCRIPTION OWNERS CERTIFICATION The foregoing instrument was acknowledged before me this _____ day of__________________, 20_____, by________________________________________________ Signature of Notary: _______________________________________________ My commission expires: ____________________________________________ address: ____________________________________________ city, state, zip: ________________________________________ NAME STATE OF COLORADO) ) ss. Name : Title : Notary Seal MMN E. HORSETOOTH RD S. TIMBERLINE RD E. DRAKE RD E POL LMN LMN UE RL RL RL LMN LMN LMN RL NC NC MMN E E E RL RL SITE E. HORSETOOTH RD EXISTING ZONING E - EMPLOYMENT PROPOSED LAND USE OFFICE MAX. BUILDING HEIGHT PERMITTED 4 STORIES FLOOR AREA RATIO 0.11 FAR 6' 2" 1" SQ. x 0.065" WALL PICKET 2.5" SQ. x 0.080" WALL POST 8' O.C. NOM. 1-3/4" FORERUNNER RAIL NOTE: FENCE SHALL BE FACTORY POWDERCOATED BLACK CHAINLINK 2" GALV. STEEL POST 2" GALV. STEEL TOP RAIL 8' O.C. TYP 6' G G G G G EXISTING SIDEWALK TO REMAIN 280'-1" 25'-8" 30' 17' 7' P.A. P.A. PA P.A. P.A. P.A. MONUMENT SIGN EXISTING BUS STOP CROSSWALK HEADQUARTERS BUILDING PA PA POOL CAR GARAGE VISITOR PARKING (29 SPACES) EMPLOYEE PARKING (81 SPACES) EMPLOYEE PARKING (77 SPACES) MICROWAVE BUILDING WAREHOUSE MAINTENANCE SHOP/ TRUCK WASH EXISTING PARKING LOT TO REMAIN (EQUIPMENT LAYDOWN AREA) NOT COUNTED TOWARD PARKING TOTAL SUBSTATION GARAGE FLEET GARAGE A POND HORSETOOTH ROAD TIMBERLINE ROAD DANFIELD COURT VEHICLE PARKING GARAGE B PROPERTY LINE PROPERTY LINE UNION PACIFIC RAILROAD TRASH ENCLOSURE, TRASH COMPACTOR, RECYCLING, 2 GENERATORS BIKE PARKING (6 SPACES) DROP OFF BIKE PARKING (10 SPACES) 177'-4" 108'-11" 34'-10" 17' 24' 30'-2" 19' 19' 26' 17' 30' 17' 27' 19' 19' 26' 17' 17' 27' 19' 19' 27' 17' P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. 47'-1" 4 EXISTING FENCE TO REMAIN EXISTING FENCE TO REMAIN SITE LIGHT, TYP. MICROWAVE TOWER (2) TRANSFORMER ENCLOSED BIKE PARKING (4 SPACES) P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. 7' LIFTING VEHICLE GATES LIFTING VEHICLE GATES 9' PROPERTY LINE BIKE PARKING (6 SPACES) 15 14 8 9 13 5 5 15 13 13 5 5 5 9 9 13 9 10 12 PERIMETER FENCE CRUSHER FINES TRAIL WITH CONCRETE HEADERS LIFTING VEHICLE GATES SLIDING VEHICLE GATE LEGEND PERIMETER FENCE SITE PLAN NORTH 0 25' 50' 100' 1603 Oakridge Drive Fort Collins, CO 80525 970-223-7577 2 OF 2 FEBRUARY 14, 2018 FINAL PLAN PLATTE RIVER POWER AUTHORITY REVISIONS: DATE: ____________________________ ______________ ____________________________ ______________ ____________________________ ______________ ____________________________ ______________ P.A. PLANTING AREA PARKING COUNT 1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 7. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 8. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 9. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 10. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 11. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS' ASSOCIATION. THE PROPERTY OWNERS' ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 12. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 13. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 14. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. SITE PLAN NOTES EXISTING FENCE LINE 5 EXISTING FENCE PERIMETER FENCE SITE AREA LOT 1 - PRPA PUD 11.797 ACRES 513,499 SF LOT 2 - COLLINDALE 4.872 ACRES 213,184 SF TOTAL 16.669 ACRES 726,683 SF LAND USE DATA BUILDING COVERAGE 68,584 SF 9% PARKING AND DRIVES 208,333 SF 29% PUBLIC ROW 0 SF 0% OPEN SPACE/LANDSCAPED AREA 452,235 SF 62% BUILDING SQUARE FOOTAGE HEADQUARTERS 55,575 SF POOL CAR GARAGE 3,264 SF WAREHOUSE (3,336 MEZZANINE OFFICE) 9,998 SF MAINTENANCE SHOP/TRUCK WASH 6,580 SF SUBSTATION GARAGE 7,930 SF FLEET PARKING A 7,948 SF FLEET PARKING B 5,912 SF TOTAL 97,207 SF PARKING DATA GENERAL OFFICE (1/1,000 SF MIN - 3/1,000 SF MAX VEHICLE SERVICE AND MAINTENANCE (2/1,000 SF MIN - 5/1,000 SF MAX) PARKING ALLOWED HEADQUARTERS (GENERAL OFFICE) 55 - 167 SPACES POOL CAR GARAGE (NO EMPLOYEES) 0 SPACES WAREHOUSE (3,400 MEZZANINE OFFICE) 3 - 10 SPACES MAINTENANCE SHOP/TRUCK WASH (VEHICLE SERVICE AND MAINTENANCE) 13 - 33 SPACES SUBSTATION GARAGE (NO EMPLOYEES) 0 SPACES FLEET PARKING A (NO EMPLOYEES) 0 SPACES FLEET PARKING B (NO EMPLOYEES) 0 SPACES TOTAL 71 - 210 SPACES PARKING PROVIDED VISITOR PARKING 29 SPACES (2 HANDICAP) EMPLOYEE PARKING 158 SPACES (6 HANDICAP) MICROWAVE BUILDING 4 SPACES _ TOTAL 191 SPACES (8 HANDICAP) BICYCLE PARKING PARKING REQUIRED (75,417/4,000) 19 SPACES (4 ENCLOSED) PARKING PROVIDED 26 SPACES PARKING LOT LANDSCAPING EMPLOYEE PARKING LOT 74,880 SF LANDSCAPE AREA 10,363 SF 13.8% VISITOR PARKING LOT 10,985 SF LANDSCAPE AREA 1,241 SF 11.3% LAND USE TABLE