HomeMy WebLinkAboutFTC AUSTI8NS SC2, WTE (VERIZON) - PDP - PDP170038 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC AUSTINS SC 02
107 N. COLLEGE AVE.
FT. COLLINS, COLORADO 80524
SMALL CELL
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
DEPART 3131 S VAUGHN WAY, AURORA, CO 80014:
HEAD SOUTH TOWARD S VAUGHN WAY. TURN RIGHT ONTO S VAUGHN WAY. TURN LEFT TO MERGE
ONTO CO-83 N TOWARD INTERSTATE 225. MERGE ONTO CO-83 N. USE THE RIGHT 3 LANES TO
TAKE THE INTERSTATE 225 S EXIT. MERGE ONTO I-225 S.
USE THE RIGHT 2 LANES TO TAKE EXIT 1B FOR INTERSTATE 25 N TOWARD FT. COLLINS. KEEP
RIGHT AND MERGE ONTO I-25 N. TAKE EXIT 269B TO MERGE ONTO CO-14 W/E MULBERRY ST
TOWARD FT. COLLINS. CONTINUE ON MULBERRY ST. TURN RIGHT ONTO RIVERSIDE AVE. TURN
LEFT ONTO MOUNTAIN AVE. THE BUILDING WILL BE ON THE RIGHT. VEHICLES CAN TEMPORARILY
PARK ALONG MOUNTAIN AVE.
FORT COLLINS, COLORADO
CLIENT
PROPERTY OWNER
JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 66211
PHONE: 913-344-2030
COLLEGE AND MOUNTAIN PROPERTIES LLC
CONTACT: STEVE TAYLOR
PHONE:970-222-8909
107 N COLLGE AVE
FT. COLLINS, CO 80524
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JASON SHELLEDY
PHONE: 970-646-1283
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
1196 GRANT STREET, UNIT 313
DENVER, CO 80203
CONTACT: RYAN SAGAR
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: Ram.Nandiraju@verizonwireless.com
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2012 (W/ LOCAL AMENDMENTS)
NEC 2014
NFPA-1 (2006)
U - UTILITY
REVISION SCHEDULE
REV
A
DATE
02-24-17
BY
MRG 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 7
SITE NAME:
FTC AUSTINS SC 02
SITE ADDRESS:
107 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0122
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 04-06-17 KRC REVISED
C 04-26-17 KRC REVISED
D 09-25-17 RPH REVISED
E 11-13-17 LCW REVISED
F 12-14-17 GAC REVISED
PHOTOSIMULATION
VIEWS
PH-1
2
4
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING NORTH)
N.T.S.
3
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTH)
N.T.S.
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTHWEST)
N.T.S.
2
PH-1
PHOTOSIMULATION VIEW (ATFER, LOOKING NORTHWEST)
N.T.S.
AC
AC
AC
AC AC
AC
AC
V
V
V V
V
V
V
V
ET
V V
V
V
UTIL UTIL UTIL UTIL
UTIL
UTIL
UTIL UTIL
V
V
V
W
S
S
FV
FV
WV
GV
EM
EM
EM
EM
EM
GM
WV
WV
WV
WM
FO
FO FO FO FO
FO
W
SD SD
W W W W
UGE
UGE UGE UGE UGE
SD
GAS GAS
R
D
EF
9'-0"
9'-0"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
AC
V
V
UTIL
UTIL UTIL UTIL
11'-0"
11'-0"
5'-0"
5'-0"
9'-0"
AC
V
ET
UTIL UTIL
W
W
FV
EM
EM
EM
EM
EM
GM
W
W W W W W W W W W
GAS
E
E
F
F
AC
UTIL UTIL
FE
10'-0"
5'-0"
REVISION SCHEDULE
REV
A
DATE
02-24-17
BY
MRG 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 7
SITE NAME:
FTC AUSTINS SC 02
SITE ADDRESS:
107 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0122
5555 CENTRAL AVENUE #100
32'-7"
32'-0"
40'-6"
26'-0"
38'-0"
32'-7"
32'-0"
26'-0"
39'-8"
41'-4"
40'-6"
TOP OF PARAPET
32'-7" AGL
GRADE
0'-0"± AGL
TOP OF ROOF
32'-0" AGL
REVISION SCHEDULE
REV
A
DATE
02-24-17
BY
MRG 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 7
SITE NAME:
FTC AUSTINS SC 02
SITE ADDRESS:
107 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0122
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 04-06-17 KRC REVISED
C 04-26-17 KRC REVISED
D 09-25-17 RPH REVISED
E 11-13-17 LCW REVISED
F 12-14-17 GAC REVISED
EXISTING
STOREFRONT
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ELEVATIONS
Z-3
5
116'-0"
Know what's below.
Call before you dig.
REVISION SCHEDULE
REV
A
DATE
02-24-17
BY
MRG 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 7
SITE NAME:
FTC AUSTINS SC 02
SITE ADDRESS:
107 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0122
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 04-06-17 KRC REVISED
C 04-26-17 KRC REVISED
D 09-25-17 RPH REVISED
E 11-13-17 LCW REVISED
F 12-14-17 GAC REVISED
LINE OF SIGHT
ELEVATIONS
Z-4
6
PROPOSED LINE OF
SIGHT FROM 5'8" IN THE
MIDDLE OF THE
SIDEWALK ACROSS W
MOUNTAIN AVE
L.O.S.
NOTE:
THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS
A VISUAL REPRESENTATION OF HOW THE SITE
WOULD APPEAR TO A 5' 8" PERSON STANDING
ON THE SIDEWALK ACROSS WEST MOUNTAIN AVE
EXISTING
CURB EXISTING DOOR
1
Z-4
PROPOSED LINE OF SIGHT ELEVATION
N.T.S.
2
Z-4
PROPOSED PERSPECTIVE ELEVATION
8'-3"
5'-5"
8'-10"
2'-10"
7'-5"
8'-0"
2'-10"
REVISION SCHEDULE
REV
A
DATE
02-24-17
BY
MRG 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 7
SITE NAME:
FTC AUSTINS SC 02
SITE ADDRESS:
107 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0122
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 04-06-17 KRC REVISED
C 04-26-17 KRC REVISED
D 09-25-17 RPH REVISED
E 11-13-17 LCW REVISED
F 12-14-17 GAC REVISED
FAUX CHIMNEY
DETAIL
Z-5
7
1
Z-5
FAUX CHIMNEY DETAIL
SCALE: 1/2"=1'-0"
1/2 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROPOSED SPARK ARRESTOR
(FINAL DESIGN TBD)
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH SPARK ARRESTOR
(SHROUD TO BE PAINTED AND TEXTURED TO
MATCH EXISTING CHIMNEY)
PROPOSED ANTENNA WITHIN
CHIMNEY CONCEALMENT
SHROUD
PROPOSED ANTENNA
MOUNTING PIPE
TOP OF EXISTING PARAPET
PROPOSED ANTENNA MOUNTING
HARDWARE
EXISTING CHIMNEY
PROPOSED 2" SNAP
IN HANGERS
PROPOSED 2" EMT
CONDUIT FOR POWER
PROPOSED 2" EMT
FOR FIBER
PROPOSED UNISTRUT
ANCHORED TO INTERIOR
OF EXISTING PARAPET
EXISTING PARAPET
WALL
PROPOSED HILTI HIT HY-70
ADHESIVE WITH 1/2" HAS-E
RODS EMBEDDED 6"
(INSTALL AS PER HILTI SPECS)
2
Z-5
CONDUIT MOUNTING DETAIL
SCALE: NTS
RF TRANSPARENT MATERIAL SPECIFICATIONS
FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES:
1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES.
2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING.
3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL.
4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN
MATRIX USED IN THE STRUCTURAL SHAPE.
5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO
PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT
BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION.
6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN
DRAWINGS.
7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS
FOLLOWS:
1/2" DIAMETER NUTS 8 FT-LBS TORQUE
5/8" DIAMETER NUTS 16 FT-LBS TORQUE
3/4" DIAMETER NUTS 24 FT-LBS TORQUE
FIBERGLASS PANEL NOTES: BY LARSON CAMOFLAGE, LLC
- FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN.
- PANELS TO BE MINIMUM 1/4" THICKNESS.
1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF
TRANSPARENT MATERIALS.
2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED
APPEARANCE.
3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT.
4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL
RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT.
5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS:
STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE
USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS.
6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE
ULTRAVIOLET PROTECTION.
7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN.
8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL
ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS.
9. CONTACT KEN PUEHL FOR ADDITIONAL INFORMATION AT 520-741-3115.
N.T.S.
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH SPARK ARRESTOR
(SHROUD TO BE PAINTED AND TEXTURED
TO MATCH EXISTING CHIMNEY)
PROPOSED VERIZON ANTENNA
MOUNTED ON CUSTOM NON-PENETRATING
SLED MOUNT UNDER SHROUD
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH SPARK ARRESTOR
(SHROUD TO BE PAINTED AND TEXTURED
TO MATCH EXISTING CHIMNEY)
EXISTING
DOOR
EXISTING
CHIMNEY
TOP OF ROOF
26'-0" AGL
PROPOSED PCS RRH MOUNTED
TO BACK OF PARAPET WALL
PROPOSED VERIZON ANTENNA MOUNTED ON CUSTOM
NON-PENETRATING SLED MOUNT UNDER SHROUD
GRADE
0'-0"± AGL
EXISTING
STOREFRONT
EXISTING
DOOR
TOP OF PARAPET
32'-7" AGL
TOP OF ROOF
32'-0" AGL
PROPOSED VERIZON RAD CENTER
38'-0" AGL
TOP OF PROPOSED VERIZON ANTENNA
39'-8" AGL
PROPOSED AWS RRH MOUNTED
TO BACK OF PARAPET WALL
PROPOSED VERIZON EQUIPMENT
CABINET MOUNTED TO BACK OF
PARAPET WALL
PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD
WITH SPARK ARRESTOR
(SHROUD TO BE PAINTED AND TEXTURED TO MATCH
EXISTING CHIMNEY)
TOP OF EXISTING CHIMNEY
40'-6" AGL
GRADE
0'-0"± AGL
TOP OF PROPOSED ANTENNA CONCEALMENT
41'-4" AGL
1
Z-3
EXISTING SOUTH ELEVATION
SCALE: 1/16"=1'-0"
2
Z-3
PROPOSED SOUTH ELEVATION
SCALE: 1/16"=1'-0"
TOP OF EXISTING CHIMNEY
40'-6" AGL
TOP OF ROOF
26'-0" AGL
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 04-06-17 KRC REVISED
C 04-26-17 KRC REVISED
D 09-25-17 RPH REVISED
E 11-13-17 LCW REVISED
F 12-14-17 GAC REVISED
3/32 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
EQUIPMENT PLAN
Z-2
4
2
Z-3
N
APPROXIMATE LOCATION
OF EXISTING
ELECTRICAL ROOM
WITHIN BUILDING
PROPOSED 11'x11'
VERIZON LEASE AREA
PROPOSED 3' WIDE TRAFFIC
MAT FROM ACCESS HATCH
FOR PROPOSED EQUIPMENT
(2) PROPOSED RRH'S AND (1) OVP MOUNTED TO
UNISTRUT ON PARAPET WALL
PROPOSED VERIZON EQUIPMENT CABINET
MOUNTED TO PARAPET WALL
PROPOSED 2'-0"X3'-0"
FIBER VAULT
(BY FIBER PROVIDER IF
REQUIRED)
PROPOSED FIBER RUN FROM
FIBER VAULT TO EQUIPMENT
CABINET MOUNTED TO
UNISTRUT ATTACHED TO
PARAPET INTERIOR WALL
(SEE DETAIL 2/Z-5)
PROPOSED ELECTRICAL RUN
FROM ELECTRICAL ROOM TO
EQUIPMENT CABINET MOUNTED
TO UNISTRUT ATTACHED TO
PARAPET INTERIOR WALL
(SEE DETAIL 2/Z-5)
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE
CODES ORDINANCES, LAWS AND REGULATIONS OF ALL
MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC
AUTHORITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY
BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR
MUNICIPAL AUTHORITIES.
3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION
MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR
OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR
PERFORMANCE OF WORK. MINOR OMISSIONS OR
ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE
THE CONTRACTOR FROM RESPONSIBILITY FOR THE
OVERALL INTENT OF THESE DRAWINGS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR
TO COMMENCING CONSTRUCTION. THE CONTRACTOR
SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF
CONSTRUCTION OF THIS FACILITY.
5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE
PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR
REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT
SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR
TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN
BE CONSTRUCTED IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS.
7. THIS PLAN WAS PREPARED USING AN APPROVED
SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF
CONSULTING, DATED 01/18/17.
8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE
MINIMIS" INCREASE IN STORMWATER RUNOFF.
THEREFORE, NO DRAINAGE STRUCTURES ARE
PROPOSED.
9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM
THIS FACILITY.
10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN
HABITATION (THERE IS NO HANDICAP ACCESS
REQUIRED).
11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE
POTABLE WATER OR SANITARY SERVICE.
12. POWER TO THE FACILITY WILL BE MONITORED BY A
SEPARATE METER.
13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND
AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION.
14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET
EIA/TIA-222-G AS PER IBC 2012 REQUIREMENTS.
15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED
GALVANIZED STEEL.
16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO
LOCATE ALL UTILITIES PRIOR TO EXCAVATING.
17. IF ANY PIPING EXISTS BENEATH THE SITE AREA,
CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS
REPRESENTATIVE.
18. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR
CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL
LENGTHS PRIOR TO ORDERING.
19. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH,
UNLESS NOTED OTHERWISE.
20. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO
VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF
DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS.
1
Z-2
EQUIPMENT PLAN
SCALE: 3/32"=1'-0"
EXISTING
BUILDING
PROPOSED VERIZON ANTENNA
MOUNTED ON CUSTOM
NON-PENETRATING SLED MOUNT
UNDER SHROUD
PROPOSED FAUX CHIMNEY
CONCEALMENT SHROUD WITH
SPARK ARRESTOR
(SHROUD TO BE PAINTED AND
TEXTURED TO MATCH EXISTING
CHIMNEY)
PROPOSED 5'x10'
VERIZON LEASE AREA
OVP
DESIGNATION
CABLE TABLE
±10'
LENGTH
1
NO. TYPE
CONDUIT
WITH 3-CELL PLENUM
FIBER IN CONDUIT
4"
FIBER RUN ±130' 1 2"
HYBRIFLEX
6x12 LOW INDUCTANCE
SIZE
MAXCELL INNERDUCT
PROPOSED VERIZON
EMON-DMON METER
ATTACHED TO WALL
INSIDE EXISTING
ELECTRICAL ROOM
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
EXISTING
BUILDING
GENERAL NOTES:
1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED
"BOUNDARY DETAIL" BY RLF CONSULTING, DATED 01/18/17.
2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN
STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE
PROPOSED.
3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS
NO HANDICAP ACCESS REQUIRED).
5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER
OR SANITARY SERVICE.
6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988
(NAVD 1988).
7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF
ANY TYPE.
8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE
OR ANY SOLID WASTE RECEPTACLES.
1 inch = 30ft.
( IN FEET )
GRAPHIC SCALE
15 0 7.5 15 30 60
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV
A
DATE
02-24-17
BY
MRG 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 7
SITE NAME:
FTC AUSTINS SC 02
SITE ADDRESS:
107 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0122
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 04-06-17 KRC REVISED
C 04-26-17 KRC REVISED
D 09-25-17 RPH REVISED
E 11-13-17 LCW REVISED
F 12-14-17 GAC REVISED
SITE PLAN
Z-1
3
MOUNTAIN AVENUE
N/F
COLLEGE AND MOUNTAIN PROPERTIES
C/O STEVE TAYLOR
107 N COLLEGE AVE.
FT. COLLINS, CO 80524
PARCEL #: 97114-05-001
LONG
LAT
SITE COORDINATES
105° 07' 74.40" WEST (NAD 83)
40° 58' 72.79" NORTH (NAD 83)
COLLEGE AVENUE
APPROXIMATE LOCATION
OF EXISTING ELECTRICAL
ROOM WITHIN BUILDING
EXISTING
PARKING LOT
PROPOSED FIBER RUN
FROM FIBER VAULT TO
EQUIPMENT CABINET
LEGEND
W
SS
F
GAS GAS
OE
UT
X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD
E
UE
OT
EV
D
O
U/G
OHW
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
PROPOSED 11'-0"x11'-0"
VERIZON LEASE AREA
PROPOSED ELECTRICAL RUN
FROM ELECTRICAL ROOM TO
EQUIPMENT CABINET
APPROXIMATE LOCATION OF
EXISTING ROOF ACCESS HATCH
PROPOSED 3' WIDE TRAFFIC MAT
FROM ACCESS HATCH FOR
PROPOSED EQUIPMENT
PROPOSED VERIZON ANTENNA MOUNTED
ON CUSTOM 10'-0"x10'-0"
NON-PENETRATING SLED MOUNT UNDER
SHROUD
PROPOSED FAUX CHIMNEY
CONCEALMENT SHROUD WITH SPARK
ARRESTOR (2'-0"x2'-0"x7'-9")
(SHROUD TO BE PAINTED AND TEXTURED
TO MATCH EXISTING CHIMNEY)
(2) PROPOSED RRH'S AND (1)
OVP MOUNTED TO UNISTRUT ON
PARAPET WALL
PROPOSED VERIZON EQUIPMENT
CABINET MOUNTED TO PARAPET
WALL
PROPOSED 2'-0"X3'-0"
FIBER VAULT BY FIBER PROVIDER
(IF NECESSARY)
1
Z-1
SITE PLAN
SCALE: 1"=30'-0"
PROPOSED 5'-0"x10'-0"
VERIZON LEASE AREA
EXISTING 2'-6"x2'-6"x14'-6"
CHIMNEY
IIB
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 EQUIPMENT PLAN
Z-3 ELEVATIONS
PROJECT DESCRIPTION
1. INSTALL NEW EQUIPMENT ON ROOFTOP BEHIND EXISTING PARAPET WALL.
2. INSTALL (1) NEW NON-PENETRATING CUSTOM SLED MOUNT ON ROOFTOP NOT VISIBLE
FROM STREET VIEW.
3. INSTALL (1) NEW FAUX CHIMNEY ATTACHED TO CUSTOM SLED MOUNT WITH CONCEALED
ANTENNA INSIDE (CHIMNEY PAINTED AND TEXTURED TO MATCH EXISTING CHIMNEY).
4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN ON STREET LEVEL.
5. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT.
6. INSTALL NEW COAX CABLES.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
VERZION PROJECT # 20161498061
JURISDICTION: TOWN OF FT. COLLINS
ZONING: D-DOWNTOWN DISTRICT
APN: 97114-05-001
PARCEL SIZE: 20,474 S.F.
ELEVATION: 4990' (NAVD 88)
SITE COORDINATES: N 40° 58' 72.79" (NAD 83)
W 105° 07' 74.40" (NAD 83)
STRUCTURE TYPE: BUILDING
STRUCTURE HEIGHT: 32'-7"± (TOP OF PARAPET)
ANTENNA RAD CENTER: 38'-0" AGL
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 662211
PH: 913-344-2030
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: 720 279-8973
REVISION SCHEDULE
REV
A
DATE
02-24-17
BY
MRG 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 7
SITE NAME:
FTC AUSTINS SC 02
SITE ADDRESS:
107 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0122
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 04-06-17 KRC REVISED
C 04-26-17 KRC REVISED
D 09-25-17 RPH REVISED
E 11-13-17 LCW REVISED
F 12-14-17 GAC REVISED
Z-4 LINE OF SIGHT ELEVATIONS
LEGAL DESCRIPTION
LOTS 1 AND 2 AND THE SOUTH 10 FEET OF LOT 3, BLOCK 21, TOWN OF FORT COLLINS
COUNTY OF LARIMER, STATE OF COLORADO
PH-1 PHOTOSIMULATION VIEW
Z-5 FAUX CHIMNEY DETAIL