Loading...
HomeMy WebLinkAboutFTC AUSTI8NS SC2, WTE (VERIZON) - PDP - PDP170038 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC AUSTINS SC 02 107 N. COLLEGE AVE. FT. COLLINS, COLORADO 80524 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: HEAD SOUTH TOWARD S VAUGHN WAY. TURN RIGHT ONTO S VAUGHN WAY. TURN LEFT TO MERGE ONTO CO-83 N TOWARD INTERSTATE 225. MERGE ONTO CO-83 N. USE THE RIGHT 3 LANES TO TAKE THE INTERSTATE 225 S EXIT. MERGE ONTO I-225 S. USE THE RIGHT 2 LANES TO TAKE EXIT 1B FOR INTERSTATE 25 N TOWARD FT. COLLINS. KEEP RIGHT AND MERGE ONTO I-25 N. TAKE EXIT 269B TO MERGE ONTO CO-14 W/E MULBERRY ST TOWARD FT. COLLINS. CONTINUE ON MULBERRY ST. TURN RIGHT ONTO RIVERSIDE AVE. TURN LEFT ONTO MOUNTAIN AVE. THE BUILDING WILL BE ON THE RIGHT. VEHICLES CAN TEMPORARILY PARK ALONG MOUNTAIN AVE. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PHONE: 913-344-2030 COLLEGE AND MOUNTAIN PROPERTIES LLC CONTACT: STEVE TAYLOR PHONE:970-222-8909 107 N COLLGE AVE FT. COLLINS, CO 80524 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT STREET, UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: Ram.Nandiraju@verizonwireless.com RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2012 (W/ LOCAL AMENDMENTS) NEC 2014 NFPA-1 (2006) U - UTILITY REVISION SCHEDULE REV A DATE 02-24-17 BY MRG 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 7 SITE NAME: FTC AUSTINS SC 02 SITE ADDRESS: 107 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0122 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-06-17 KRC REVISED C 04-26-17 KRC REVISED D 09-25-17 RPH REVISED E 11-13-17 LCW REVISED F 12-14-17 GAC REVISED PHOTOSIMULATION VIEWS PH-1 2 4 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING NORTH) N.T.S. 3 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTH) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTHWEST) N.T.S. 2 PH-1 PHOTOSIMULATION VIEW (ATFER, LOOKING NORTHWEST) N.T.S. AC AC AC AC AC AC AC V V V V V V V V ET V V V V UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL V V V W S S FV FV WV GV EM EM EM EM EM GM WV WV WV WM FO FO FO FO FO FO W SD SD W W W W UGE UGE UGE UGE UGE SD GAS GAS R D EF 9'-0" 9'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH AC V V UTIL UTIL UTIL UTIL 11'-0" 11'-0" 5'-0" 5'-0" 9'-0" AC V ET UTIL UTIL W W FV EM EM EM EM EM GM W W W W W W W W W W GAS E E F F AC UTIL UTIL FE 10'-0" 5'-0" REVISION SCHEDULE REV A DATE 02-24-17 BY MRG 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 7 SITE NAME: FTC AUSTINS SC 02 SITE ADDRESS: 107 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0122 5555 CENTRAL AVENUE #100 32'-7" 32'-0" 40'-6" 26'-0" 38'-0" 32'-7" 32'-0" 26'-0" 39'-8" 41'-4" 40'-6" TOP OF PARAPET 32'-7" AGL GRADE 0'-0"± AGL TOP OF ROOF 32'-0" AGL REVISION SCHEDULE REV A DATE 02-24-17 BY MRG 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 7 SITE NAME: FTC AUSTINS SC 02 SITE ADDRESS: 107 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0122 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-06-17 KRC REVISED C 04-26-17 KRC REVISED D 09-25-17 RPH REVISED E 11-13-17 LCW REVISED F 12-14-17 GAC REVISED EXISTING STOREFRONT 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS Z-3 5 116'-0" Know what's below. Call before you dig. REVISION SCHEDULE REV A DATE 02-24-17 BY MRG 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 7 SITE NAME: FTC AUSTINS SC 02 SITE ADDRESS: 107 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0122 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-06-17 KRC REVISED C 04-26-17 KRC REVISED D 09-25-17 RPH REVISED E 11-13-17 LCW REVISED F 12-14-17 GAC REVISED LINE OF SIGHT ELEVATIONS Z-4 6 PROPOSED LINE OF SIGHT FROM 5'8" IN THE MIDDLE OF THE SIDEWALK ACROSS W MOUNTAIN AVE L.O.S. NOTE: THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS A VISUAL REPRESENTATION OF HOW THE SITE WOULD APPEAR TO A 5' 8" PERSON STANDING ON THE SIDEWALK ACROSS WEST MOUNTAIN AVE EXISTING CURB EXISTING DOOR 1 Z-4 PROPOSED LINE OF SIGHT ELEVATION N.T.S. 2 Z-4 PROPOSED PERSPECTIVE ELEVATION 8'-3" 5'-5" 8'-10" 2'-10" 7'-5" 8'-0" 2'-10" REVISION SCHEDULE REV A DATE 02-24-17 BY MRG 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 7 SITE NAME: FTC AUSTINS SC 02 SITE ADDRESS: 107 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0122 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-06-17 KRC REVISED C 04-26-17 KRC REVISED D 09-25-17 RPH REVISED E 11-13-17 LCW REVISED F 12-14-17 GAC REVISED FAUX CHIMNEY DETAIL Z-5 7 1 Z-5 FAUX CHIMNEY DETAIL SCALE: 1/2"=1'-0" 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED SPARK ARRESTOR (FINAL DESIGN TBD) PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH SPARK ARRESTOR (SHROUD TO BE PAINTED AND TEXTURED TO MATCH EXISTING CHIMNEY) PROPOSED ANTENNA WITHIN CHIMNEY CONCEALMENT SHROUD PROPOSED ANTENNA MOUNTING PIPE TOP OF EXISTING PARAPET PROPOSED ANTENNA MOUNTING HARDWARE EXISTING CHIMNEY PROPOSED 2" SNAP IN HANGERS PROPOSED 2" EMT CONDUIT FOR POWER PROPOSED 2" EMT FOR FIBER PROPOSED UNISTRUT ANCHORED TO INTERIOR OF EXISTING PARAPET EXISTING PARAPET WALL PROPOSED HILTI HIT HY-70 ADHESIVE WITH 1/2" HAS-E RODS EMBEDDED 6" (INSTALL AS PER HILTI SPECS) 2 Z-5 CONDUIT MOUNTING DETAIL SCALE: NTS RF TRANSPARENT MATERIAL SPECIFICATIONS FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES: 1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES. 2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING. 3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL. 4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPE. 5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION. 6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN DRAWINGS. 7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS FOLLOWS: 1/2" DIAMETER NUTS 8 FT-LBS TORQUE 5/8" DIAMETER NUTS 16 FT-LBS TORQUE 3/4" DIAMETER NUTS 24 FT-LBS TORQUE FIBERGLASS PANEL NOTES: BY LARSON CAMOFLAGE, LLC - FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN. - PANELS TO BE MINIMUM 1/4" THICKNESS. 1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF TRANSPARENT MATERIALS. 2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED APPEARANCE. 3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT. 4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT. 5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS: STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS. 6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE ULTRAVIOLET PROTECTION. 7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN. 8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS. 9. CONTACT KEN PUEHL FOR ADDITIONAL INFORMATION AT 520-741-3115. N.T.S. PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH SPARK ARRESTOR (SHROUD TO BE PAINTED AND TEXTURED TO MATCH EXISTING CHIMNEY) PROPOSED VERIZON ANTENNA MOUNTED ON CUSTOM NON-PENETRATING SLED MOUNT UNDER SHROUD PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH SPARK ARRESTOR (SHROUD TO BE PAINTED AND TEXTURED TO MATCH EXISTING CHIMNEY) EXISTING DOOR EXISTING CHIMNEY TOP OF ROOF 26'-0" AGL PROPOSED PCS RRH MOUNTED TO BACK OF PARAPET WALL PROPOSED VERIZON ANTENNA MOUNTED ON CUSTOM NON-PENETRATING SLED MOUNT UNDER SHROUD GRADE 0'-0"± AGL EXISTING STOREFRONT EXISTING DOOR TOP OF PARAPET 32'-7" AGL TOP OF ROOF 32'-0" AGL PROPOSED VERIZON RAD CENTER 38'-0" AGL TOP OF PROPOSED VERIZON ANTENNA 39'-8" AGL PROPOSED AWS RRH MOUNTED TO BACK OF PARAPET WALL PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO BACK OF PARAPET WALL PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH SPARK ARRESTOR (SHROUD TO BE PAINTED AND TEXTURED TO MATCH EXISTING CHIMNEY) TOP OF EXISTING CHIMNEY 40'-6" AGL GRADE 0'-0"± AGL TOP OF PROPOSED ANTENNA CONCEALMENT 41'-4" AGL 1 Z-3 EXISTING SOUTH ELEVATION SCALE: 1/16"=1'-0" 2 Z-3 PROPOSED SOUTH ELEVATION SCALE: 1/16"=1'-0" TOP OF EXISTING CHIMNEY 40'-6" AGL TOP OF ROOF 26'-0" AGL BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-06-17 KRC REVISED C 04-26-17 KRC REVISED D 09-25-17 RPH REVISED E 11-13-17 LCW REVISED F 12-14-17 GAC REVISED 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EQUIPMENT PLAN Z-2 4 2 Z-3 N APPROXIMATE LOCATION OF EXISTING ELECTRICAL ROOM WITHIN BUILDING PROPOSED 11'x11' VERIZON LEASE AREA PROPOSED 3' WIDE TRAFFIC MAT FROM ACCESS HATCH FOR PROPOSED EQUIPMENT (2) PROPOSED RRH'S AND (1) OVP MOUNTED TO UNISTRUT ON PARAPET WALL PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO PARAPET WALL PROPOSED 2'-0"X3'-0" FIBER VAULT (BY FIBER PROVIDER IF REQUIRED) PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT CABINET MOUNTED TO UNISTRUT ATTACHED TO PARAPET INTERIOR WALL (SEE DETAIL 2/Z-5) PROPOSED ELECTRICAL RUN FROM ELECTRICAL ROOM TO EQUIPMENT CABINET MOUNTED TO UNISTRUT ATTACHED TO PARAPET INTERIOR WALL (SEE DETAIL 2/Z-5) GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 01/18/17. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET EIA/TIA-222-G AS PER IBC 2012 REQUIREMENTS. 15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. 18. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 19. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 20. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. 1 Z-2 EQUIPMENT PLAN SCALE: 3/32"=1'-0" EXISTING BUILDING PROPOSED VERIZON ANTENNA MOUNTED ON CUSTOM NON-PENETRATING SLED MOUNT UNDER SHROUD PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH SPARK ARRESTOR (SHROUD TO BE PAINTED AND TEXTURED TO MATCH EXISTING CHIMNEY) PROPOSED 5'x10' VERIZON LEASE AREA OVP DESIGNATION CABLE TABLE ±10' LENGTH 1 NO. TYPE CONDUIT WITH 3-CELL PLENUM FIBER IN CONDUIT 4" FIBER RUN ±130' 1 2" HYBRIFLEX 6x12 LOW INDUCTANCE SIZE MAXCELL INNERDUCT PROPOSED VERIZON EMON-DMON METER ATTACHED TO WALL INSIDE EXISTING ELECTRICAL ROOM ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N EXISTING BUILDING GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 01/18/17. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 15 0 7.5 15 30 60 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 02-24-17 BY MRG 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 7 SITE NAME: FTC AUSTINS SC 02 SITE ADDRESS: 107 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0122 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-06-17 KRC REVISED C 04-26-17 KRC REVISED D 09-25-17 RPH REVISED E 11-13-17 LCW REVISED F 12-14-17 GAC REVISED SITE PLAN Z-1 3 MOUNTAIN AVENUE N/F COLLEGE AND MOUNTAIN PROPERTIES C/O STEVE TAYLOR 107 N COLLEGE AVE. FT. COLLINS, CO 80524 PARCEL #: 97114-05-001 LONG LAT SITE COORDINATES 105° 07' 74.40" WEST (NAD 83) 40° 58' 72.79" NORTH (NAD 83) COLLEGE AVENUE APPROXIMATE LOCATION OF EXISTING ELECTRICAL ROOM WITHIN BUILDING EXISTING PARKING LOT PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT CABINET LEGEND W SS F GAS GAS OE UT X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD E UE OT EV D O U/G OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING PROPOSED 11'-0"x11'-0" VERIZON LEASE AREA PROPOSED ELECTRICAL RUN FROM ELECTRICAL ROOM TO EQUIPMENT CABINET APPROXIMATE LOCATION OF EXISTING ROOF ACCESS HATCH PROPOSED 3' WIDE TRAFFIC MAT FROM ACCESS HATCH FOR PROPOSED EQUIPMENT PROPOSED VERIZON ANTENNA MOUNTED ON CUSTOM 10'-0"x10'-0" NON-PENETRATING SLED MOUNT UNDER SHROUD PROPOSED FAUX CHIMNEY CONCEALMENT SHROUD WITH SPARK ARRESTOR (2'-0"x2'-0"x7'-9") (SHROUD TO BE PAINTED AND TEXTURED TO MATCH EXISTING CHIMNEY) (2) PROPOSED RRH'S AND (1) OVP MOUNTED TO UNISTRUT ON PARAPET WALL PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO PARAPET WALL PROPOSED 2'-0"X3'-0" FIBER VAULT BY FIBER PROVIDER (IF NECESSARY) 1 Z-1 SITE PLAN SCALE: 1"=30'-0" PROPOSED 5'-0"x10'-0" VERIZON LEASE AREA EXISTING 2'-6"x2'-6"x14'-6" CHIMNEY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 EQUIPMENT PLAN Z-3 ELEVATIONS PROJECT DESCRIPTION 1. INSTALL NEW EQUIPMENT ON ROOFTOP BEHIND EXISTING PARAPET WALL. 2. INSTALL (1) NEW NON-PENETRATING CUSTOM SLED MOUNT ON ROOFTOP NOT VISIBLE FROM STREET VIEW. 3. INSTALL (1) NEW FAUX CHIMNEY ATTACHED TO CUSTOM SLED MOUNT WITH CONCEALED ANTENNA INSIDE (CHIMNEY PAINTED AND TEXTURED TO MATCH EXISTING CHIMNEY). 4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN ON STREET LEVEL. 5. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT. 6. INSTALL NEW COAX CABLES. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 VERZION PROJECT # 20161498061 JURISDICTION: TOWN OF FT. COLLINS ZONING: D-DOWNTOWN DISTRICT APN: 97114-05-001 PARCEL SIZE: 20,474 S.F. ELEVATION: 4990' (NAVD 88) SITE COORDINATES: N 40° 58' 72.79" (NAD 83) W 105° 07' 74.40" (NAD 83) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 32'-7"± (TOP OF PARAPET) ANTENNA RAD CENTER: 38'-0" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 662211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV A DATE 02-24-17 BY MRG 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 7 SITE NAME: FTC AUSTINS SC 02 SITE ADDRESS: 107 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0122 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 04-06-17 KRC REVISED C 04-26-17 KRC REVISED D 09-25-17 RPH REVISED E 11-13-17 LCW REVISED F 12-14-17 GAC REVISED Z-4 LINE OF SIGHT ELEVATIONS LEGAL DESCRIPTION LOTS 1 AND 2 AND THE SOUTH 10 FEET OF LOT 3, BLOCK 21, TOWN OF FORT COLLINS COUNTY OF LARIMER, STATE OF COLORADO PH-1 PHOTOSIMULATION VIEW Z-5 FAUX CHIMNEY DETAIL