Loading...
HomeMy WebLinkAboutFORT COLLINS JEEP - FDP - FDP170035 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSSOUTH MASON STREET (CROSS-SECTION G) NOT TO SCALE WALK 72' R.O.W. 6' PROPOSED VERTICAL CURB & GUTTER EXISTING VERTICAL CURB & GUTTER 12' PROPOSED R.O.W. EXISTING R.O.W. CONC. SIDEWALK 5' 12' BIKE LANE LEFT TURN LANE EXISTING THRU LANE EXISTING R.O.W. THRU LANE 2.5' 12' 12' RIGHT TURN LANE 8' 2.5' 12' 60' SOUTH MASON STREET (CROSS-SECTION H) NOT TO SCALE 72' R.O.W. 6' 2.5' PROPOSED VERTICAL CURB & GUTTER 5.5' 12' PLANTING AREA PROPOSED R.O.W. EXISTING R.O.W. CONC. SIDEWALK 5' BIKE LANE 5' THRU LANE EXISTING THRU LANE EXISTING BIKE LANE EXISTING R.O.W. 2.5' 2.5' 12' 8' EXISTING WALK EXISTING VERTICAL GENERAL NOTES (CITY OF FORT COLLINS AND LARIMER COUNTY): 1. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF PUBLIC IMPROVEMENTS SHALL MEET OR EXCEED THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LARIMER COUNTY URBAN AREA STREET STANDARDS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE MOST RESTRICTIVE STANDARD SHALL APPLY. ALL WORK SHALL BE INSPECTED AND APPROVED BY THE LOCAL ENTITY. 2. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE. 3. THESE PUBLIC IMPROVEMENT CONSTRUCTION PLANS SHALL BE VALID FOR A PERIOD OF THREE YEARS FROM THE DATE OF APPROVAL BY THE LOCAL ENTITY ENGINEER. USE OF THESE PLANS AFTER THE EXPIRATION DATE WILL REQUIRE A NEW REVIEW AND APPROVAL PROCESS BY THE LOCAL ENTITY PRIOR TO COMMENCEMENT OF ANY WORK SHOWN IN THESE PLANS. 4. THE ENGINEER WHO HAS PREPARED THESE PLANS, BY EXECUTION AND/OR SEAL HEREOF, DOES HEREBY AFFIRM RESPONSIBILITY TO THE LOCAL ENTITY, AS BENEFICIARY OF SAID ENGINEER’S WORK, FOR ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS, AND APPROVAL OF THESE PLANS BY THE LOCAL ENTITY ENGINEER SHALL NOT RELIEVE THE ENGINEER WHO HAS PREPARED THESE PLANS OF ALL SUCH RESPONSIBILITY. FURTHER, TO THE EXTENT PERMITTED BY LAW, THE ENGINEER HEREBY AGREES TO HOLD HARMLESS AND INDEMNIFY THE LOCAL ENTITY, AND ITS OFFICERS AND EMPLOYEES, FROM AND AGAINST ALL LIABILITIES, CLAIMS, AND DEMANDS WHICH MAY ARISE FROM ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS. 5. ALL SANITARY SEWER, STORM SEWER, AND WATER LINE CONSTRUCTION, AS WELL AS POWER AND OTHER “DRY” UTILITY INSTALLATIONS, SHALL CONFORM TO THE LOCAL ENTITY STANDARDS AND SPECIFICATIONS CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENTITY ENGINEER. 6. THE TYPE, SIZE, LOCATION AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK BEFORE COMMENCING NEW CONSTRUCTION. THE DEVELOPER SHALL BE RESPONSIBLE FOR UNKNOWN UNDERGROUND UTILITIES. 7. THE ENGINEER SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) AT 1- 800-922-1987, AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING EXCAVATION OR GRADING, TO HAVE ALL REGISTERED UTILITY LOCATIONS MARKED. OTHER UNREGISTERED UTILITY ENTITIES (I.E. DITCH / IRRIGATION COMPANY) ARE TO BE LOCATED BY CONTACTING THE RESPECTIVE REPRESENTATIVE. UTILITY SERVICE LATERALS ARE ALSO TO BE LOCATED PRIOR TO BEGINNING EXCAVATION OR GRADING. IT SHALL BE LARIMER COUNTY URBAN AREA STREET STANDARDS – REPEALED AND REENACTED APRIL 1, 2007 ADOPTED BY LARIMER COUNTY, CITY OF LOVELAND, CITY OF FORT COLLINS PAGE E-1-FC/LAR-1 THE RESPONSIBILITY OF THE DEVELOPER TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 8. THE DEVELOPER SHALL BE RESPONSIBLE FOR PROTECTING ALL UTILITIES DURING CONSTRUCTION AND FOR COORDINATING WITH THE APPROPRIATE UTILITY COMPANY FOR ANY UTILITY CROSSINGS REQUIRED. IF A CONFLICT EXISTS BETWEEN EXISTING AND PROPOSED UTILITIES AND/OR A DESIGN MODIFICATION IS REQUIRED, THE DEVELOPER SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. DESIGN MODIFICATION(S) MUST BE APPROVED BY THE LOCAL ENTITY PRIOR TO BEGINNING CONSTRUCTION. 9. THE DEVELOPER SHALL COORDINATE AND COOPERATE WITH THE LOCAL ENTITY, AND ALL UTILITY COMPANIES INVOLVED, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION AND WITH A MINIMUM DISRUPTION OF SERVICE. THE DEVELOPER SHALL BE RESPONSIBLE FOR CONTACTING, IN ADVANCE, ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE AS WELL AS THE UTILITY COMPANIES. 10. NO WORK MAY COMMENCE WITHIN ANY PUBLIC STORM WATER, SANITARY SEWER OR POTABLE WATER SYSTEM UNTIL THE DEVELOPER NOTIFIES THE UTILITY PROVIDER. NOTIFICATION SHALL BE A MINIMUM OF 2 WORKING DAYS PRIOR TO COMMENCEMENT OF ANY WORK. AT THE DISCRETION OF THE WATER UTILITY PROVIDER, A PRE-CONSTRUCTION MEETING MAY BE REQUIRED PRIOR TO COMMENCEMENT OF ANY WORK. 11. THE DEVELOPER SHALL SEQUENCE INSTALLATION OF UTILITIES IN SUCH A MANNER AS TO MINIMIZE POTENTIAL UTILITY CONFLICTS. IN GENERAL, STORM SEWER AND SANITARY SEWER SHOULD BE CONSTRUCTED PRIOR TO INSTALLATION OF THE WATER LINES AND DRY UTILITIES. 12. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 13. A STATE CONSTRUCTION DEWATERING WASTEWATER DISCHARGE PERMIT IS REQUIRED IF TRAFFIC SIGNING AND PAVEMENT MARKING CONSTRUCTION NOTES: 1. ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE. 2. ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC. 3. ALL SIGNAGE SHALL BE PER LOCAL ENTITY STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. 4. ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS. 5. ALL LANE LINES FOR CONCRETE PAVEMENT SHOULD BE EPOXY PAINT. 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMENT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE LOCAL ENTITY ENGINEER PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS. 7. PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS. 8. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. 9. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. 10. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS. 11. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE LOCAL ENTITY ENGINEER. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. 12. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 13. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. 14. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD, THE LOCAL ENTITY ENGINEER RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE LOCAL ENTITY ENGINEER DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). 15. SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC CONTROL DEVICES, FOR ADDITIONAL DETAIL. REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE X X X X X X X X X X X X X X X X X X X X EXIST. MEDIAN CURB (EXIST. ASPHALT ROADWAY) WEST HARMONY ROAD SOUTH MASON STREET (60' R.O.W.) (R.O.W. WIDTH VARIES) EXIST. TRAFFIC LIGHT POLE TO REMAIN EXIST. 2-STORY METAL BUILDING W/ ADD-ONS TO REMAIN (REFERENCE ARCHITECTURAL PLANS) LOT 1 PEDERSON AUTO PLAZA SUBDIVISION (EXIST. ASPHALT ROADWAY) TRANSFORT BUS STOP EXIST. BACK OF CURB BUS ROAD TO REMAIN CITY OF FORT COLLINS REC. NO. 20120033213 5040 5042 5044 5042 5042 5042 5046 5044 5044 5050 5046 5048 5046 5042 5044 5040 5044 5042 5044 5046 5046 5046 5046 5048 5046 5046 5046 X X X X X X X X X X X X X X X X X X X X MEDIAN CURB (ASPHALT) WEST HARMONY ROAD SOUTH MASON STREET (60' R.O.W.) (R.O.W. WIDTH VARIES) TRAFFIC LIGHT POLE 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 31,553 S.F. FINISHED FLOOR = 5045.9 LOT 1 PEDERSEN AUTO PLAZA SUBDIVISION 2ND FILING (ASPHALT) TRANSFORT BUS STOP BACK OF CURB BUS ROAD CITY OF FORT COLLINS REC. NO. 20120033213 SS SS S S S S S S W W W W W W W W W W S S S S S S S S S W W W W W W W W W W W W W S S S S S EXIST. METAL SHED EXIST. METAL SHED TRANSFORMER N 1434390.80 E 3116578.59 N 1434320.81 E 3116577.26 X X X X X X X X X X X X X X X X MEDIAN CURB (ASPHALT) WEST HARMONY ROAD SOUTH MASON STREET (60' R.O.W.) (R.O.W. WIDTH VARIES) 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 31,553 S.F. FINISHED FLOOR = 5045.9 LOT 1 PEDERSEN AUTO PLAZA SUBDIVISION 2ND FILING (ASPHALT) TRANSFORT BUS STOP CITY OF FORT COLLINS REC. NO. 20120033213 5040 5042 5044 5042 5042 5042 5046 5044 5044 5050 5046 5048 5046 5042 5044 5040 5044 5042 5044 5046 5046 5046 5046 5048 5046 5046 5046 SS SS S S S S S S W W W W W W X X X X X X X X X X X X X X X X X X X X 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 31,553 S.F. FINISHED FLOOR = 5045.9 LOT 1 PEDERSEN AUTO PLAZA SUBDIVISION 2ND FILING CITY OF FORT COLLINS REC. NO. 20120033213 SS SS S S S S S S W W W W W W W W W W S S S S S S S S W W W W W W W W W W W W W S S S S S OIL AND SAND INTERCEPTOR (SEE DETAIL THIS SHEET) 6" - 90° BEND FIRELINE 6" WET TAP W/ TB W W W W S S S S S S S S S S S S S M S S S S S S S S W W W W W W W 4 EX. STREET LIGHT TO BE RELOCATED W W W W W W W W W W W W W W W W W W W W W W W W S S S S S S S SOUTH MASON STREET 60' EXISTING R.O.W. 72' PROPOSED R.O.W. 15.5' 8.5' BEGIN CONSTRUCTION MATCH EXIST. C&G N 1434389.88 E 3117026.69 END CONSTRUCTION MATCH EXIST. C&G N 1433898.76 E 3116977.24 WEST HARMONY ROAD 7.3' ASPHALT PAVEMENT 4 0+00 1+00 2+00 3+00 4+00 5+00 5+41 BP: 0+00.00 EP: 5+41.15 PI: 0+04.06 PI: 0+24.23 PI: 0+36.74 PI: 1+12.99 PI: 5+11.41 PI: 2+31.02 PI: 3+09.29 PC: 4+69.65 PT: 5+11.31 STA: 4+50.00 / 2.00' (R) ELEV: 5038.32 FL STA: 4+00.00 / 2.00' (R) STA: 3+50.00 / 2.00' (R) ELEV: 5038.69 FL ELEV: 5039.17 FL STA: 3+00.00 / 1.99' (R) ELEV: 5039.68 FL STA: 2+50.00 / 1.99' (R) ELEV: 5040.13 FL STA: 2+00.00 / 2.00' (R) ELEV: 5040.43 FL STA: 1+50.00 / 2.00' (R) ELEV: 5040.68 FL EXIST. LIP OF PAN STA: 1+12.99 / 2.00' (R) ELEV: 5040.90 FL STA: 0+35.63 / 2.00' (R) ELEV: 5041.46 FL 4 STA: 4+69.60 / 2.00' (R) 0+07 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 0+74 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 SECTION DATA 2+00 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 SECTION DATA PROPOSED R.O.W. PROPOSED R.O.W. PROPOSED R.O.W. 5041.80 5041.73 5041.80 5041.82 5042.56 5042.29 5041.50 5041.42 5041.70 5041.36 5042.59 5041.79 5044.25 5042.01 5044.45 5042.76 5044.60 5042.87 5040.85 5040.76 5041.26 5040.60 5043.24 5042.57 5044.35 5043.42 3+18 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 4+00 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 SECTION DATA 4+69 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 SECTION DATA PROPOSED R.O.W. PROPOSED R.O.W. PROPOSED R.O.W. 5040.06 5040.37 5039.93 5041.27 5039.66 5042.66 5040.14 5043.66 5043.58 5044.12 5043.89 5044.56 5044.19 5039.56 5039.39 5039.34 5040.29 5038.86 5041.09 5039.34 5041.77 5043.04 5042.37 5043.27 5043.21 5043.50 X X X X X X X X X X X 6' 11' 21' 15' U.E. REMOVE EXISTING TREE RELOCATED "BUS STOP" SIGN R10' R25' SS SS S S S S S S S S S W W W W W W W W W W W W W W S S S S S S S S S S S S W W W W REMOVE AND RELOCATE STREET LIGHT CONCRETE SIDEWALK 0+00 1+00 1+53 STA: 0+12.47 / 2.00' (L) ELEV: 5046.17 STA: 0+16.34 / 2.73' (L) ELEV: 5046.14 STA: 0+45.35 / 12.26' (L) ELEV: 5045.95 STA: 0+50.03 / 13.01' (L) ELEV: 5045.92 STA: 0+95.53 / 13.00' (L) ELEV: 5044.94 STA: 0+99.64 / 12.43' (L) ELEV: 5044.82 STA: 1+22.96 / 5.79' (L) ELEV: 5044.15 STA: 1+32.00 / 7.65' (L) ELEV: 5044.28 STA: 1+41.07 / 26.43' (L) ELEV: 5045.13 N 1433890.51 E 3116595.07 N 1433895.00 E 3116747.70 ONLY ONLY EXIST. BIKE LANE STRIPE TO REMAIN EXIST. STOP BAR TO REMAIN 12' 12.3' 12' 120' 150' 16.5' 8.5' ±13.4' EXIST. BIKE LANE SIGN TO BE RELOCATED EXISTING STOP BAR STRIPE TO BE EXTENDED TO NEW LIP OF PAN PROPOSED PEDESTRIAN CROSS WALK STRIPING EXISTING DOUBLE YELLOW STRIPING TO BE REMOVED EXIST. BIKE LANE STRIPE TO REMAIN SOUTH MASON STREET EXIST. TRAFFIC SIGNAL POLE TO REMAIN EXIST. R.O.W. PROPOSED R.O.W. EXIST. CURB, GUTTER, & WALK EXIST. PEDESTRIAN SIGNAL BUTTON & POST TO BE RELOCATED 4 2 4 6 1 EXIST. BIKE LANE STRIPE TO BE REMOVED EXIST. R.O.W. "HANDICAP ACCESS LOCATED ON W. HARMONY ROAD" SIGN 10 5' 3 3 3 MATCH EXIST. DBL YELLOW STRIPING EXIST. BIKE LANE STRIPE TO BE REMOVED ±12' EXISTING TURNING LANE STRIPING TO BE REMOVED SOUTH MASON STREET ONLY ONLY 8 9 9 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 10 FORT COLLINS JEEP FIRE LANE SIGNAGE & STRIPING PLAN TWD 11/20/2017 1" = 30' WLB 16-018 C-12 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 FORT COLLINS JEEP DETAILS TWD 11/20/2017 N/A WLB 16-018 C-13 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE X-SECTION A-A: POROUS LANDSCAPE DETENTION POND (BIORETENTION) DETAILS N.T.S 8" THICK SECTION OF CDOT NO. 4 AGGREGATE 12" FILTER MEDIA (SEE SPECIFICATION ON THIS SHEET. CLEANOUT ORIFICE PLATE FOR 100-YR CONTROL AT PIPE INLET 100-YR GRATE PAVEMENT WQCV ELEV = "C" POND BOTTOM ELEV = "A" OUTLET PIPE INV.: "B" DEBRIS GRATE 2' CATCH GUTTER & 6" CURB HEAD 2' CATCH GUTTER FORT COLLINS JEEP DETAILS TWD 11/20/2017 N/A WLB 16-018 C-14 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE OUTLET STRUCTURE DETAIL N.T.S FORT COLLINS JEEP DETAILS TWD 11/20/2017 N/A WLB 16-018 C-15 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE FORT COLLINS JEEP DETAILS TWD 11/20/2017 N/A WLB 16-018 C-16 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE FORT COLLINS JEEP DETAILS TWD 11/20/2017 N/A WLB 16-018 C-17 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE FORT COLLINS JEEP DETAILS TWD 11/20/2017 N/A WLB 16-018 C-18 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE M W W W W W W W 4 X X X X X X X X X X X X X X X X SS SS S S S S S S W W W W W W W W W W S S S S S S W W W W W W W W W W W W W S S S S S ONLY ONLY . .. . .. . . . . . .. ... . . . .. . .. .... ..... . .. . .. . ..... . . . ... . .. ... .. .. ........ .. ..... . . ... .. .. . . . ... .. . . .... . . . ..... ... ..... ... ... ... . .. . . . ... . . . .. ... .. ...... ... ...... . . . .... . . . . .................................... ...... . ..... . .... . ........ . ...... ........ . .......... . .... . .......... . ... . . . ... ............ ........ .. ... . .... . . .. .. .. . .. ............... .. . .. . . .. . . . . . .. . .. ..... . ..... .. ..... . ..... .. .... .. .. . . .. . . . .. . .... . . .. . A 0.22 0.93 1.16 E 0.39 N/A N/A F 0.42 N/A N/A G 0.56 N/A N/A C 1.72 0.89 B 1.12 0.33 0.89 1.11 . . .. . . ... D 0.15 N/A N/A .... . .. .. . ... . .. .. . ......... . . . . . . .. . ... . .... . ... . .. . .. . . . . . .. . .. . ... . ...... . ... . . . . . . . . . . .. . .. . . . .. . .. . .. .... . 5045 5043 5044 5045 5044 5046 5045 5046 5047 5045 5044 5041 5042 5040 5045 5039 5041 5042 5043 5044 5045 5046 1 2 3 5045 5045 5043 5043 5044 5044 5046 5046 5040 5039 5039 5041 5042 4.43% 2.63% 3.14% 2.44% 1.56% 1.10% 1.63% 1.66% 4.51% 5045 5044 5045.59 FL 5045.07 FL 5044.49 FL 5044.42 FL 5043.76 FL 5044.12 FL 5043.59 FL 5043.3 FL 5043.48 FL 5043.7 FL 5043.9 FL 5043.4 FL 5043.95 FL 5044.63 FL 5044.05 FL 5044.18 FL 5042.37 FG 5041.58 FG WQ RELEASE STRUCTURE WQ RELEASE STRUCTURE WQ RELEASE STRUCTURE 6" 90° BEND 6" - TEE 6"-90° BEND 6" CLEANOUT 6" - 11.25° Bend 6" - Tee and 6" - 11.25° Bend 15 LF~ 6" HDPE 100 LF~ 6" HDPE 100 LF~ 6" HDPE 135 LF~ 6" HDPE 16 LF~ 6" HDPE 8 LF~ 6" 6" HDPE PIPE 43 LF~ 6" HDPE 99 LF~ 6" HDPE 15 LF~ 6" HDPE 31 LF~ 6" HDPE 113 LF~ 6" HDPE 4" CLEANOUT 4" CLEANOUT 26 LF~ 4" A-2000 SLOTTED PIPE 90 LF~ 4" A-2000 SLOTTED PIPE 88 LF~ 4" A-2000 SLOTTED PIPE 62 LF~ 4" A-2000 SLOTTED PIPE 5047.2 EOA 5045.76 FL 5045.10 FL 5044.52 FL 5042.36 FL ??? FG ??? FG 5045.97 FL 5044.54 FL 5044.88 FG 5044.78 FL 5045.04 FL 5045.88 FG 5045.90 FG 18 LF~ 4" A-2000 SLOTTED PIPE 18 LF~ 4" A-2000 SLOTTED PIPE WQ/BIORETENTION BASIN A VOLUME REQUIRED = 0.006 AC-FT VOLUME PROVIDED = 0.006 AC-FT WQ/BIORETENTION BASIN B VOLUME REQUIRED = 0.009 AC-FT VOLUME PROVIDED = 0.009 AC-FT WQ/BIORETENTION BASIN C VOLUME REQUIRED = 0.042 AC-FT VOLUME PROVIDED = 0.042 AC-FT 0.39% 0.04% 0.49% 0.50% 0.43% 0.46% 1.85% 1.59% 1.63% 1.67% 0.46% 0.42% 0.03% 1.26% 0.31% 0.37% 0.61% 1.00% Runoff Analysis Data Table Basin ID C2 C100 Q2 (cfs) Q100 (cfs) A 0.87 0.95 0.53 2.02 B 0.83 0.92 0.76 2.94 C 0.80 0.89 3.33 12.96 PROPOSED 15' TYPE R INLET PROPOSED 4' DIA. STORM MANHOLE CONNECT AND OUTLET TO EXISTING STORM SEWER EXISTING STORM SEWER REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R FORT COLLINS JEEP DRAINAGE PLAN TWD 11/20/2017 1" = 30' MSG 16-018 C-19 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 30 60 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION DRAINAGE LEGEND BASIN NAME 2yr C VALUE BASIN ACREAGE 100yr C VALUE 5820 5820 EX. MAJOR CONTOUR EX. MINOR CONTOUR PR. MAJOR CONTOUR PR. MINOR CONTOUR PROPOSED BASIN BOUNDARY LINE 1 BASIN AREA 2yr 100yr PR. STORM EX. STORM BASIN LABEL DESIGN POINT PROPOSED CONCRETE 10' "E" "F" & 6" CURB HEAD X-SECTION B-B: POROUS LANDSCAPE DETENTION POND (BIORETENTION) DETAILS N.T.S PAVEMENT WITH NO CURB AND GUTTER WQCV ELEV = "C" POND BOTTOM ELEV = "A" PAVEMENT WITH NO CURB AND GUTTER WHEEL STOP 2' 2' WHEEL STOP 8" 4 1 8" 4 1 18" THICK SECTION OF FILTER MEDIA (SEE "BIORETENTION/BIOSWALE CROSS SECTION" ON THIS SHEET) 8" THICK SECTION OF CDOT NO. 4 AGGREGATE "H" DIA HOLE ORIFICE PLATE FOR UNDERDRAIN 2' X 5' FENCE NOTE: 1. CONTRACTOR IS REQUIRED TO PROVIDE SAMPLE OF THE FILTER MEDIA MATERIALS AFTER DELIVERY AND PRIOR TO PLACEMENT. DETAIL AND SPECIFICATION NOTES: 1. REFER TO SECTION B DETAILS BELOW (PER UDFCD, VOL. 3 CHAPTER 4, SECTION T-3, PAGE B-16) FOR NO-INFILTRATION SECTION. 1. FOR GEOMEMBRANE LINER/CONCRETE CONNECTION DETAILS, SEE FIGURE B-3 RIGHT. 2. FOR MATERIAL SPECIFICATION OF THE POROUS LANDSCAPE DETENTION (BIORETENTION) POND, AND IMPERMEABLE LINER SPECIFICATION REQUIREMENTS, SEE TABLE B-1 RIGHT. 3. FOR SEPARATOR FABRIC PHYSICAL REQUIREMENTS, SEE TABLE B-2. POND TABLE "A" "B" "C" "D" "E" "F" "G" "H" POND "A" 5043.70 5041.70 5044.90 N/A 27.13 3.52 0.91 0.38" POND "B" 5042.80 5040.80 5044.00 N/A 64.98 3.33 0.98 0.46" POND "C" 5041.70 5039.70 5042.90 82.65 (WEST)* 90.18 (EAST)* N/A 0.96 1.02" * (SEE PLAN) OUTLET STRUCTURE DETAIL N.T.S 4" CONTECH A-2000 SLOTTED PIPE UNDISTURBED EARTH 6" PEA GRAVEL DIAPHRAM WQCV 6" "G" 280' "D" "G" 22.7' 2" 2" 4" CONTECH A-2000 SLOTTED PIPE C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 30 60 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' SIGNAGE AND STRIPING LEGEND: 1 STOP BAR - PRE-FORMED 90 MIL THERMOPLASTIC 3 4" WIDE PAINTED SOLID WHITE EDGE LINE 6" WIDE SOLID WHITE TURNING LANE LINE 6" WIDE DASHED WHITE TURNING LANE LINE 4 4" WIDE DOUBLE YELLOW CENTERLINE STRIPING 5 "NO PARKING" SIGN (R, L, OR D) 6 PEDESTRIAN CROSS WALK - PRE-FORMED 90 MIL 2 THERMOPLASTIC 7 8 "NO PARKING FIRE LANE SIGN" 9 CURB PAINTED RED "FIRE LANE" R7-1 10 "HANDICAP ACCESS ON W. HARMONY ROAD" NOTE: SEE SHEET C-11 FOR SOUTH MASON STREET AND WEST HARMONY ROAD ROADWAY SIGNAGE & STRIPING PLAN. SS SS WEST HARMONY ROAD (R.O.W. WIDTH VARIES) EXIST. "STOP HERE ON RED" SIGN TO BE RELOCATED EXIST. STREET LIGHT WITH "40 MPH" SIGN TO BE RELOCATED EXIST. PEDESTRIAN CROSSING AHEAD SIGN TO REMAIN EXIST. STREET LIGHT WITH "RAIL ROAD CROSSING" SIGN TO REMAIN EXIST. BUS STOP SIGN TO BE RELOCATED EXIST. TRAFFIC SIGNAL POLE TO REMAIN ALL EXIST. W. HARMONY ROAD STRIPING TO REMAIN LOCATION OF RELOCATED "BUS STOP" SIGN 2 1 FORT COLLINS JEEP ROADWAY SIGNAGE & STRIPING PLAN TWD 11/20/2017 -1" = 20' WLB 16-018 C-11 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 20 40 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' SIGNAGE AND STRIPING LEGEND: 1 STOP BAR - PRE-FORMED 90 MIL THERMOPLASTIC 3 4" WIDE PAINTED SOLID WHITE EDGE LINE 6" WIDE SOLID WHITE TURNING LANE LINE 6" WIDE DASHED WHITE TURNING LANE LINE 4 4" WIDE DOUBLE YELLOW CENTERLINE STRIPING 5 "NO PARKING" SIGN (R, L, OR D) 6 PEDESTRIAN CROSS WALK - PRE-FORMED 90 MIL 2 THERMOPLASTIC 7 8 "NO PARKING FIRE LANE SIGN" 9 CURB PAINTED RED "FIRE LANE" R7-1 10 "HANDICAP ACCESS ON W. HARMONY ROAD" 2.00% WEST HARMONY ROAD (R.O.W. WIDTH VARIES) SOUTH MASON STREET (EX. 60' R.O.W.) N85°46'32"E 12.47' N88°30'17"E 125.18' N88°51'35"E 15.06' RELOCATED STREET LIGHT REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R FORT COLLINS JEEP BUS STOP PLAN TWD 11/20/2017 1" = 20' JLC 16-018 C-10 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 20 40 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION BUS STOP DETAIL REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Varies CONCRETE BUS PAD - ATTACHED Street Do not construct in wheel lane. 1/2" Expansion Joint Material (typical) Attached Sidewalk (width variable) 10" min. 2" 11'-0" 2'-0" 6" Thick Curb ASPHALT A A Lip F BOC BOW Existing 2'-0" Gutter 1/2" Pre-formed Sealed Expansion Joint Material 50'-0" min Contraction Joint 10'-0" Flow Line SECTION A-A (Typ) Existing Sidewalk Taper in accordance with the Table below. NOTE: 1. Length of bus pad varies as directed by the Local Entity. 2. All pads shall be a minimum of 10" thick concrete. 12'-0" or Lane Width 2'-0" CONCRETE BUS PAD - DETACHED Concrete in wheel lane. Do not construct 6" 1/2" Expansion Joint Material (typical) L T.C. F Lip BUS BAY TRANSITION LENGTHS Detached Sidewalk SPEED LIMIT LEAD IN LENGTH (Li) (FT.) LEAD OUT LENGTH (Lo) (FT.) <35 60 60 40 100 70 45 150 80 50 200 90 55 250 100 (width variable) Lo 15' R Li FL * Joints 15' R Provide Curved Connections R=15' The Local Entity Transit Authority shall specify this length. * BUS BAY BUS STOP L 2'-0" 6" 10'-0" min. 10'-0" 2'-0" Varies Street 12'-0" or Lane Width Concrete FL T.C. Lip 10'-0" min. 10'-0" 2'-0" 5038.81 5038.92 5038.68 5039.38 5038.47 5040.10 5038.94 5040.85 5040.42 5041.57 5041.98 CONC SW 8' CONC. SIDEWALK 8' CONC. SIDEWALK 6 STEPS 4:1 -2.00% -2.00% 5038.30 FL 5038.69 FL 5039.49 FL EL: 5040.00 EXIST LIP OF PAN EL: 5040.15 BACK SW -2.55% 5043.46 FL EL: 5039.5 EXIST LIP OF PAN EL: 5039.35 BACK SW -2.20% 5042.84 FL REPLACE ASPHALT PAVEMENT. EL: 5038.47 EXIST LIP OF PAN EL: 5038.94 BACK SW 5042.08 FL REPLACE ASPHALT PAVEMENT. REPLACE ASPHALT PAVEMENT. 13.5' 13.5' 6.6' NOTE: NEW ASPHALT PAVEMENT SHALL MATCH EXIST PAVEMENT SECTION DEPTH TO SUBGRADE. 5043.44 TS 5043.44 FL SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' LANDSCAPE WALL -2.00% -2.28% -0.85% -2.28% -0.85% -3.98% -0.84% -2.54% 4 N 1433898.69 3+00 4+00 5+00 PI: 5+11.41 PI: 3+09.29 PC: 4+69.65 PT: 5+11.31 STA: 3+18.30 STA: 4+00 STA: 4+69.22 PROPOSED R.O.W. EXIST. R.O.W. CONC. SIDEWALK STA: 4+00.00 / 2.00' (R) ELEV: 5038.69 FL STA: 4+69.22 / 2.00' (R) ELEV: 5038.30 FL STA: 3+18.30 / 2.00' (R) ELEV: 5039.49 FL 5044 5040 5042 5040 5040 5044 5042 R=26.94' L=41.66' Δ=88°35'00" S89°38'10"W 0.10' 8' EDGE OF EXIST LIP SOUTH MASON STREET Know what'sbelow. Call before you dig. R FORT COLLINS JEEP MASON STREET CROSS SECTIONS TWD 11/20/2017 1" = 10' NRM 16-018 C-9.2 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 10 20 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' 5044.58 5043.83 5044.79 5044.11 EXIST CONC SW 8' CONC. SIDEWALK 4:1 ASPH PVMT 4:1 5041.65 FL 5041.12 FL 5040.43 FL -2.00% EL: 5041.82 MEET & MATCH EXIST LIP OF PAN EL: 5042.26 BACK SW -6.22% EL: 5041.36 BACK SW EL: 5041.82 BACK SW EL: 5042.02 BACK SW EL: 5040.74 EXIST LIP OF PAN EL: 5042.71 BACK SW 5043.79 FL -2.86% NOTE: NEW ASPHALT PAVEMENT SHALL MATCH EXIST PAVEMENT SECTION DEPTH TO SUBGRADE. REPLACE ASPH PVMT REPLACE ASPHALT PAVEMENT. 3.2' 6.8' -2.00% 8.33% 10' ASPH PVMT ASPH PVMT -2.0% SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' -2.05% -0.85% -2.05% -0.85% 0.66% 60' EXISTING R.O.W. 72' PROPOSED R.O.W. N 1434393.94 E 3117026.80 0+00 1+00 2+00 BP: 0+00.00 PI: 0+04.06 PI: 0+24.23 PI: 0+36.74 PI: 1+12.99 PI: 2+31.02 STA: 0+06.81 STA: 0+73.69 STA: 2+00 PROPOSED R.O.W. EXIST. R.O.W. STA: 2+00.00 / 2.00' (R) ELEV: 5040.43 FL STA: 0+73.69 / 2.00' (R) ELEV: 5041.12 FL STA: 0+06.81 / 2.00' (R) ELEV: 5041.65 FL 5042 5044 5044 5042 5044 S01°34'26"W 4.06' S03°19'09"W 20.17' S01°22'45"W 12.51' S06°04'20"W 76.26' 10' 15' U.E. 2.00% 5041.8 FG 5042.02 FG 5042.0 FG SOUTH MASON STREET EDGE OF EXIST LIP REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE Know what'sbelow. Call before you dig. R FORT COLLINS JEEP MASON STREET CROSS SECTIONS TWD 11/20/2017 1" = 10' NRM 16-018 C-9.1 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 10 20 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' ELEV: 5038.30 FL STA: 5+11.45 / 2.00' (R) ELEV: 5039.41 FL KENSINGTON DRIVE S03°19'09"W 20.17' S06°04'20"W 76.26' R=26.94' L=41.66' Δ=88°35'00" S89°38'10"W 0.10' S01°34'26"W 4.06' S01°22'45"W 12.51' S01°03'05"W 118.03' S05°48'54"W 78.27' S01°03'05"W 160.36' EXIST. LIP OF PAN EXIST. LIP OF PAN EXIST.TRAFFIC SIGNAL POLE TO REMAIN EXIST. TRAFFIC SIGNAL CONTROL BOXES LANDSCAPE WALL LANDSCAPE WALL STORM SEWER INLET EXIST. GROUND @ PROPOSED LIP OF GUTTER SCALE: HORIZONTAL 1"=20' VERTICAL 1"= 2' MASON STREET PROFILE 5035 5040 5050 5035 5040 5050 0+00 1+00 2+00 3+00 4+00 5+00 5+25 -0.90% -0.50% -0.70% -0.66% -0.50% -0.60% -0.90% -1.01% 0.00% 0.50% 3.00% PVI STA = 0+05.00 ELEV = 5041.84 PVI STA = 1+00.37 ELEV = 5041.17 PVI STA = 1+50.51 ELEV = 5040.84 PVI STA = 2+00.23 ELEV = 5040.60 PVI STA = 2+50.55 ELEV = 5040.29 PVI STA = 3+00.78 ELEV = 5039.84 PVI STA = 3+80.67 ELEV = 5039.03 PVI STA = 4+30.79 ELEV = 5038.58 PVI STA = 4+55.67 ELEV = 5038.46 PVI STA = 4+67.11 ELEV = 5038.46 PVI STA = 4+75.54 ELEV = 5038.50 PVI STA = 5+11.59 ELEV = 5039.58 -0.90% -0.50% -0.70% -0.66% -0.50% -0.60% -0.90% -1.01% 0.00% 0.50% 3.00% PVI STA = 0+05.00 ELEV = 5041.84 PVI STA = 1+00.37 ELEV = 5041.17 PVI STA = 1+50.51 ELEV = 5040.84 PVI STA = 2+00.23 ELEV = 5040.60 PVI STA = 2+50.55 ELEV = 5040.29 PVI STA = 3+00.78 ELEV = 5039.84 PVI STA = 3+80.67 ELEV = 5039.03 PVI STA = 4+30.79 ELEV = 5038.58 PVI STA = 4+55.67 ELEV = 5038.46 PVI STA = 4+67.11 ELEV = 5038.46 PVI STA = 4+75.54 ELEV = 5038.50 PVI STA = 5+11.59 ELEV = 5039.58 PROPOSED GROUND @ PROPOSED LIP OF GUTTER 5041.80 5041.33 5041.52 5041.69 5041.18 5041.46 5040.85 5041.26 5040.60 5041.15 5040.30 5041.85 5039.85 5039.96 5039.34 5040.29 5038.86 5039.97 5038.49 5039.22 5039.23 5039.79 5039.79 FORT COLLINS JEEP MASON STREET WIDENING PLAN TWD 11/20/2017 1" = 20' WLB 16-018 C-8 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 20 40 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). NOTE: SEE SHEET C-11 FOR E. MASON STREET SIGNAGE AND STRIPING PLAN. 67.7' MEDIAN CURB (ASPHALT) WEST HARMONY ROAD SOUTH MASON STREET (R.O.W. WIDTH VARIES) TEL. TRANSFORT BUS STOP EX. 8" WATER EX. 8" SANITARY 158 LF ~ 6" DIP 100 LF ~ 6" PVC CORP STOP CURB STOP 135 LF~TYPE ~ 1 1/2" TYPE 'K' COPPER 1-1/2" METER 19 LF ~ 6" DIP 71 LF ~ 6" PVC 100 LF ~ 6" PVC 6" SWIVEL TEE 6" PLUG W/ TB 30 LF ~ 6" DIP 6" SEWER SERVICE 6" SEWER SERVICE 115 LF ~ 6" PVC "BUS STOP" EX. TRAFFIC LIGHT POLE TO REMAIN EX. INLET GRATE EX. TRANSFORMER BIKE RACK (4) EXIST. WATER METER TO BE RECYCLED EXIST. FIRE HYDRANT TO BE RELOCATED EX. SEWER SERVICE TO BE ABANDONED IN PLACE EX. 10" AC WATER EX. 12 " STORM 15' U.E. EX. COMMS 15' U.E. EXIST. 5' U.E. 20' EMERGENCY ACCESS ESMT. RELOCATED STREET LIGHT 4 10' Type R Inlet N=1433933.28 E=3117002.26 INV. IN = 5036.91 Type 13 Inlet w/ Solid Cover N=1433933.28 E=3117013.60 Type C Outlet Structure N=1433985.53 E=3116858.01 INV. OUT = 5039.70 6" Cleanout N=1434094.50 E=3116645.37 INV. = 5041.77 Type C Outlet Structure N=1434194.50 E=3116662.07 INV. OUT = 5041.70 Type C Outlet Structure N=1434051.02 E=3116661.87 INV. OUT = 5040.80 6" - 90° Bend N=1434194.50 E=3116645.37 INV. = 5042.27 6" - Tee N=1434051.22 E=3116645.37 6" - 90° Bend N=1433952.53 E=3116645.37 INV. = 5041.06 6" - 11.25° Bend N=1433933.28 6" - Tee and E=3116969.86 6" - 11.25° Bend N=1433952.53 E=3116858.01 INV. = 5040.0 100LF ~ 6" HDPE SD 113LF 6" ~ 6" SD HDPE SD 6" Cleanout N=1433952.53 E=3116745.37 INV. = 5040.56 SEE SHEET C-10 FOR DETIALS SEE SHEET C-10 FOR DETAILS SEE SHEET C-10 FOR DETAILS 6" GV 5 LF~6" DIP 8' 3' RELOCATED FIRE HYDRANT EX. STORM INLET TO BE REPLACED :,7+ ‘0$1+2/( INV. OUT SW (12") = 5036.89 SEWER SERVICE TO BE ABANDONED AT MANHOLE RELOCATE EX. SIGN EX. STORM MANHOLE INV. IN NE (12") = 5035.96 ,19,11:   “ INV. OUT SW = 5032.51 EX. SAN. MANHOLE INV. OUT N = 5031.41 EX. SAN. MANHOLE INV. IN S = 5031.18 INV. IN E = 5031.20 INV. OUT N = 5031.03 EX. SAN. MANHOLE INV. IN S = 5031.00 INV. OUT NW = 5030.90 6" SERVICE INV. = 5031.27± VEHICLE STORAGE CUSTOMER EMPLOYEE EMPLOYEE VEHICLE DISPLAY CUSTOMER 4"Ø X 30" H, PIPE BOLLARDS, FILL WITH CONC. CAP AND PAINT, TYP. INSTALL @ 6' 0.C. 4" PVC STORM DRAIN CLEANOUT 4" PVC STORM DRAIN CLEANOUT 2' WIDE CURB-CUT 2' WIDE CURB-CUT 4" PVC STORM DRAIN CLEANOUT 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE 4" PVC STORM DRAIN CLEANOUT 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 15' DRAINAGE ESMT. 15' DRAINAGE ESMT. 15' DRAINAGE ESMT. 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE CONNECT TO EXIST. 8" WATERLINE WITH WET TAP 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE N 1434390.80 E 3116578.59 N 1434389.41 E 3117002.13 N 1433925.66 N 1433912.65 E 3116993.62 E 3116980.38 N 1433909.92 E 3116607.92 N 1434133.98 E 3116612.20 N 1434133.98 E 3116607.20 N 1434215.26 E 3116608.75 N 1434215.35 E 3116603.75 6" CLEAN-OUT N 1434336.00 E 3116767.37 6" CLEAN-OUT N 1434336.00 E 3116838.16 6" CLEAN-OUT N 1434336.00 E 3116938.16 6" CLEAN-OUT N 1434221.04 E 3116772.37 10' (ASPHALT PARKING LOT) 99LF ~ 6" HDPE SD 135LF ~ 6" HDPE SD 16LF ~ 6" HDPE SD 43LF ~ 6" HDPE SD 100LF ~ 6" HDPE SD 17LF ~ 6" HDPE SD 33LF ~ 6" HDPE SD 11LF ~ 6" HDPE SD 17LF ~ 6" HDPE SD 20' W.L. ESMT. 15' U.E. BNSF RAIL-ROAD R.O.W. 100' (ASPHALT PARKING LOT) (ASPHALT PARKING LOT) CONC. DRAINAGE CHANNEL Feet 0 30 60 FORT COLLINS JEEP OVERALL UTILITY PLAN TWD 03/15/2017 1" = 30' JLC 16-018 C-7 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE PROPERTY LINE LOT / TRACT LINE LEGEND: S S W W EXISTING SANITARY LINE W/ MH EXISTING STORM LINE W/ MH EXISTING WATER LINE EXISTING STORM AREA INLET EXISTING FIRE HYDRANT EXISTING WATER VALVE D Y H EXISTING STORM TYPE 'R' INLET RIGHT-OF-WAY E E EXISTING ELECTRIC LINE G G EXISTING GAS LINE X X EXISTING FENCE LINE 5530 PROPOSED CONTOUR 5530 EXISTING CONTOUR S S PROPOSED SANITARY SEWER W/ MH PROPOSED STREET SIGN PROPOSED STORM SEWER W/ MH W W PROPOSED WATER LINE PROPOSED FIRE HYDRANT CTV EXISTING CATV LINE CENTERLINE R.O.W. EXISTING CONCRETE PROPOSED EASEMENT LINE EXISTING EASEMENT LINE PROPOSED WATER VALVE PROPOSED WATER FITTINGS 4 5 PROPOSED TYPE 'R' INLET PROPOSED FLARED END SECTION EXISTING RIGHT-OF-WAY PROPOSED STREET LIGHT D S COM COM EXISTING COMMUNICATION LINE PROPOSED LANDSCAPE PROPOSED ASPHALT PROPOSED CONCRETE SIDEWALK REPAIR NOTE: ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. OIL AND SAND INTERCEPTOR Know what'sbelow. Call before you dig. R BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' STREET CUT NOTE: LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. W W W W S S S S S S W W W W W W W W W W W W W S S S S S 4 5045 5044 5046 5045 5043 5044 5045 5044 5045 5045 5045 5040 5041 EXIST. METAL SHED EXIST. METAL SHED SSA 30' X 60' VT 131 LF SF RS LOC CWA SF SF SF SF LOC LOC LOC 76 LF SF 271 LF SF SF SF SF SF SF SF SF SF SF SF 340 LF SF RS RS IP RS RS SF SF SF SF SF SF CF 225 LF RS RS RS RS RS SF SF SF SF SF SF SF SF 27 LF SF 342 LF SF 41 LF SF IP PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS N 1434390.80 E 3116578.59 N 1434320.81 E 3116577.26 N 1434215.35 E 3116603.75 N 1434215.26 E 3116608.75 N 1434133.98 E 3116607.20 N 1434133.98 E 3116612.20 N 1433909.92 E 3116607.92 N 1433912.65 E 3116980.38 N 1433925.66 E 3116993.62 N 1434389.41 E 3117002.13 3.0% 0.0% 2.8% 0.5% 1.9% 2.9% 0.6% 0.5% 2.4% 2.8% 3.7% 0.5% 1.6% 2.0% 0.9% 0.5% 1.8% 1.7% 0.5% 5.0% 1.4% ??? ??? 4.7% 0.6% 1.0% 2.0% 4.2% 2.6% 3.9% 5.2% 1.0% 2.4% 2.4% 2.1% 1.9% 1.3% 6.8% 2.0% 0.1% 1.6% 0.4% 0.4% 1.0% 1.1% 3.3% 1.3% 1.2% 3.5% TRAFFIC LIGHT POLE BACK OF CURB BUS ROAD TRANSFORMER TEMPORARY INLET PROTECTION TO BE REMOVED ON REMOVAL OF EXISTING INLET 100' BNSF RAIL-ROAD R.O.W. CONC. DRAINAGE CHANNEL Feet 0 30 60 FORT COLLINS JEEP EROSION CONTROL PLAN TWD 11/20/2017 1" = 30' JLC 16-018 C-6 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE SF LIMITS OF CONSTRUCTION SF CWA CF IP PS SSA VTC LOC CONCRETE WASHOUT AREA CONSTRUCTION FENCE INLET PROTECTION PERMANENT SEEDING SILT FENCE STABILIZED STAGING AREA VEHICLE TRACKING CONTROL BMP LEGEND RS ROCK SOCK BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Know what'sbelow. Call before you dig. R CONSTRUCTION SEQUENCE CHART PROPERTY LINE EXISTING LOT/TRACT LINE LEGEND: S W EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER MAIN EXISTING STORM MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING RIGHT-OF-WAY E G EXISTING GAS MAIN X EXISTING FENCE 5530 PROPOSED CONTOUR 5530 EXISTING CONTOUR PROPOSED AREA OUTLET PROPOSED STORM SEWER CTV EXISTING CATV LINE EXISTING UTILITY RISER EXISTING STREET SIGN 5537.30 FL 2% PROPOSED SLOPE PROPOSED FLOWLINE ELEVATION EXISTING VEGETATION EXISTING BURIED ELECTRIC LINE EXISTING SANITARY SEWER MH COM EXISTING COMMUNICATION LINE HIGH POINT LOW POINT HP LP FG FINISH GRADE N 1434215.35 E 3116603.75 N 1434215.26 E 3116608.75 N 1434133.98 E 3116607.20 N 1434133.98 E 3116612.20 N 1433909.92 E 3116607.92 N 1433912.65 E 3116980.38 N 1433925.66 E 3116993.62 N 1434389.41 E 3117002.13 3.0% 0.0% 2.8% 0.5% 1.9% 2.9% 0.6% 0.5% 2.4% 2.8% 3.7% 0.5% 1.6% 0.8% 0.5% 1.8% 1.7% 0.5% 5.0% 1.4% ??? ??? 4.7% 2.0% 4.2% 2.7% 3.9% 5.2% 1.0% 2.4% 2.4% 2.1% 1.9% 1.3% 6.7% 2.0% 0.1% 1.6% 0.4% 0.4% 1.0% 1.1% 3.3% 1.3% 1.2% 3.5% 1.2% 2.5% 100' BNSF RAIL-ROAD R.O.W. 5040 5042 5044 5042 5042 5042 5046 5044 5044 5050 5046 5048 5046 5040 5044 5042 5044 5046 5046 5046 5046 5048 5046 5046 5046 5040 5041 5044.85 FL 5044.38 FL 5044.56 FL 5044.25 FL 5043.22 FL 5043.68 FL 5043.55 FL 5043.16 FL 5043.08 LP 5043.36 FL 5043.41 FL 5043.52 FL 5044.71 FL 5045.49 FL 5045.16 FL 5043.84 FL 5043.71 FL 5044.24 FL 5044.12 FL 5044.31 FL 5044.18 FL 5044.43 FL 5044.25 FL 5044.43 FL 5044.88 FL 5044.71 FL 5045.00 FL 5045.16 FL 5045.35 FL 5044.76 FL 5044.92 FL 5045.06 FL 5045.68 FL 5045.47 FL 5045.70 FL 5044.63 FL 5044.44 FL 5044.66 FL 5043.97 FL 5043.86 FL 5044.17 FL 5044.25 FL 5044.31 FL 5044.93 FL 5044.61 FL 5045.14 FL 5044.66 FL 5044.74 FL 5045.19 HP 5045.39 FL 5045.90 FL 5044.92 FL 5045.47 FL 5045.25 FL 5045.19 FL 5045.40 FL 5044.86 FL 5045.17 FL 5045.07 FL 5045.51 FL 5045.97 FL 5045.91 FL 5045.91 FL 5045.90 FL 5045.95 FL 5045.76 FL 5045.89 FL 5045.54 FL 5045.68 FL 5045.68 FL 5045.55 FL 5045.86 FL 5045.75 FL 5046.02 FL 5045.95 FL 5046.03 FL 5044.15 FL 5044.03 FL 5044.52 FL 5044.57 FL 5042.34 FL 5042.77 FL 5042.56 FL 5045.77 FL 5045.51 FL 5045.13 FL 5045.47 FL 5045.61 FL 5045.48 FL 5045.56 FL 5045.05 FL 5045.28 FL 5045.26 FL 5045.02 FL 5044.34 FL 5044.77 FL 5045.00 FL 5044.72 FL 5044.22 FL 5043.88 FL 5044.09 FL 5045.13 HP 5043.22 FL 5043.73 FL 5046.11 FG 5046.05 FG 5045.79 FG 5045.72 FG 5046.69 FG 5046.66 FG 5046.38 FG 5046.35 FG 5047.17 FG 5045.40 FL 5044.72 FL ??? FG 5046.65 FG 5039.95 FG 5046.08 FG 5046.27 FG ??? FG ??? FG ??? FG ??? FG 5046.50 FG 5046.01 FG 5041.66 FL 5041.46 FL 5040.90 FL 5045.60 FL 5045.04 FL 5044.99 FL 5045.90 FL 5044.68 FL 5043.75 FL 5044.27 FL 5042.01 FL 5042.52 FL 5043.85 FL 5044.22 FL 5044.25 FL 5043.73 FL 5043.85 FL 5043.88 FL 5044.05 FL 5042.46 FL 5042.33 FL 5042.06 FL 5043.59 FL 5043.74 FL 5043.78 FG 5043.95 FL 5045.90 FL 5042.23 FL 5044.54 FL 5042.96 FL 5042.67 FL 5042.35 FL 5042.32 FL 5042.41 FL 5044.06 FL 5044.48 FL 5044.54 FL 5042.24 FL 5045.90 FL 5045.90 FL 5042.17 LP 5042.90 FL 5045.83 FL 5044.59 FL 5044.59 FL 5044.43 FL 5044.45 FL 5044.56 FL 5042.82 FL 5042.76 HP 5044.15 FL 5043.82 FL CONC. DRAINAGE CHANNEL 5045 5046 5044 5040 5041 5042 5040 5042 5043 5040 5044 5043 5045 5044 5044 G G H H TOW=5039.77 BOW=5039.65 TOW=5043.41 BOW=5041.11 TOW=5043.40 BOW=5042.36 TOW=5043.99 BOW=5043.91 5044.34 FL LANDSCAPE WALL LANDSCAPE WALL 5044.11 FL 5044.15 FL 5045.90 FL 5045.63 FL 5045.73 FL 5045.84 FL 5045.90 FL 5045.74 FL 5044.41 FL 5045.23 FL 5.0% 5042.36 FL 2.0% 1.5% 2.0% 0.5% 1.2% Feet 0 30 60 FORT COLLINS JEEP GRADING PLAN TWD 11/20/2017 1" = 30' JLC 16-018 C-5 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 PROPERTY LINE EXISTING LOT/TRACT LINE LEGEND: S W EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER MAIN EXISTING STORM MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING RIGHT-OF-WAY E G EXISTING GAS MAIN X EXISTING FENCE 5530 PROPOSED CONTOUR 5530 EXISTING CONTOUR PROPOSED AREA OUTLET S PROPOSED SANITARY SEWER PROPOSED SIGN > > PROPOSED C.L. SWALE PROPOSED STORM SEWER W PROPOSED WATER MAIN PROPOSED FIRE HYDRANT CTV EXISTING CATV LINE EXISTING UTILITY RISER EXISTING STREET SIGN 5537.30 FL 2% PROPOSED SLOPE PROPOSED FLOWLINE ELEVATION PROPOSED STREET LIGHT EXISTING VEGETATION PROPOSED PHASING LINE EXISTING BURIED ELECTRIC LINE EXISTING SANITARY SEWER MH EXISTING ASPHALT PAVEMENT PROPOSED ROADWAY STRIPING PROPOSED ASPHALT PAVEMENT PROPOSED CONCRETE PAVEMENT PROPOSED DRAINAGE FLOW ARROW COM EXISTING COMMUNICATION LINE PROPOSED CLEANOUT HIGH POINT LOW POINT HP LP FG FINISH GRADE REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Know what'sbelow. Call before you dig. R SS SS S S S S S S W W W W W W W W W W S S S S S S S S S W W W W W W W W W W W W W S S S S S EXIST. METAL SHED TO REMAIN EXIST. METAL SHED TO REMAIN EXIST. BUS STOP SHELTER , PAD, & 57.2 LF SIDEWALK TO EXIST. CURB & GUTTER BE REMOVED TO BE REMOVED EXIST. CURB & GUTTER TO BE REMOVED ±178.7' EXIST. ASPHALT TO BE REMOVED EXIST. CURB & GUTTER TO BE REMOVED EXIST. CURB, GUTTER, & ADA RAMPS TO BE REMOVED EXIST. SHRUBS TO BE REMOVED EXIST. BUSHES & TREES TO BE REMOVED EXIST. INLET TO BE REMOVED “/)2)(;,67&85% GUTTER & SIDEWALK TO BE REMOVED EXIST. CURB & GUTTER TO BE REMOVED EXIST. HYDRANT TO BE RELOCATED EXIST. SAN SEWER SERVICE LINE TO BE ABANDONED IN PLACE EXIST. WATER METER TO BE RECYCLED EXIST. CONC. TO BE REMOVED EXIST. ASPHALT TO BE REMOVED EXIST. ASPHALT TO BE REMOVED EXIST. CURB & GUTTER TO BE REMOVED EXIST. ELEC. TRANSFORMER TO REMAIN EXIST. ROADWAY STRIPING TO BE ERADICATED EXIST. CONC. TO BE REMOVED EXIST. "STOP HERE ON RED" SIGN TO BE RELOCATED EXIST. STREET LIGHT WITH "40 MPH" SIGN TO BE RELOCATED EXIST. PEDESTRIAN CROSSING AHEAD SIGN TO REMAIN EXIST. STREET LIGHT WITH "RIAL ROAD CROSSING" SIGN TO REMAIN EXIST. BUS STOP SIGN TO BE RELOCATED EXIST. TREES & SHRUBS TO REMAIN EXIST. DRAINAGE PAN & SIDEWALK CHASE TO REMAIN EXIST. TREE TO REMAIN EXIST. AREA LIGHT EXIST. TREES TO BE REMOVED TO REMAIN EXIST. AREA LIGHTS TO BE REMOVED 57.2' EXIST. BIKE LANE STRIPE TO REMAIN EXIST. STOP BAR TO REMAIN PROPERTY LINE R.O.W. R.O.W. PROPERTY LINE EXIST. CHAIN-LINK FENCE TO REMAIN EXIST. WOOD FENCE TO REMAIN EXIST. CHAIN-LINK FENCE TO BE REMOVED EX. CONC. PAN TO BE REMOVED EXIST. CONC. PAN AND ADA RAMPS TO BE REMOVED ± 91 LF EXIST. CONC. SIDEWALK TO BE REMOVED EXIST. GRAVEL DRIVEWAY / PARKING 100' BNSF RAIL-ROAD R.O.W. Feet 0 30 60 FORT COLLINS JEEP DEMOLITION PLAN TWD 11/20/2017 1" = 30' JLC 16-018 C-4 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Know what'sbelow. Call before you dig. R STREET CUT NOTE: LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPERTY LINE EXISTING LOT/TRACT LINE LEGEND: S W EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER MAIN EXISTING STORM MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING RIGHT-OF-WAY E G EXISTING GAS MAIN X EXISTING FENCE 5530 EXISTING CONTOUR CTV EXISTING CATV LINE EXISTING UTILITY RISER EXISTING STREET SIGN EXISTING BURIED ELECTRIC LINE EXISTING SANITARY SEWER MH EXISTING ASPHALT PAVEMENT COM EXISTING COMMUNICATION LINE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE FORT COLLINS JEEP CONSTRUCTION NOTES TWD 11/20/2017 1" = 30' JLC 16-018 C-3 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 STORM DRAINAGE NOTES: 1. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S). 19. ALL RECOMMENDATIONS OF THE FINAL DRAINAGE REPORT FORT COLLINS JEEP DEALERSHIP BY PARAGON ENGINEERING DATED MAY 26, 2017 AND EROSION AND SEDIMENT CONTROL ASSOCIATED WITH CONSTRUCTION ACTIVITIES FOR FORT COLLINS JEEP DEALERSHIP BY PARAGON ENGINEERING DATED AUGUST 29, 2017 SHALL BE FOLLOWED AND IMPLEMENTED. 20. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS, CERTIFICATION OF THE DRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BY SUBMITTED TO AND APPROVED BY THE STORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BY SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT. DEWATERING IS REQUIRED IN ORDER TO INSTALL UTILITIES OR WATER IS DISCHARGED INTO A STORM SEWER, CHANNEL, IRRIGATION DITCH OR ANY WATERS OF THE UNITED STATES. 14. THE DEVELOPER SHALL COMPLY WITH ALL TERMS AND CONDITIONS OF THE COLORADO PERMIT FOR STORM WATER DISCHARGE (CONTACT COLORADO DEPARTMENT OF HEALTH, WATER QUALITY CONTROL DIVISION, (303) 692-3590), THE STORM WATER MANAGEMENT PLAN, AND THE EROSION CONTROL PLAN. 15. THE LOCAL ENTITY SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S). 17. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE LOCAL ENTITY, CERTIFICATION OF THE DRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BE SUBMITTED TO AND APPROVED BY THE STORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT. 18. THE LOCAL ENTITY SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES OR INJURIES SUSTAINED IN THIS DEVELOPMENT AS A RESULT OF GROUNDWATER SEEPAGE, WHETHER RESULTING FROM GROUNDWATER LARIMER COUNTY URBAN AREA STREET STANDARDS – REPEALED AND REENACTED APRIL 1, 2007 ADOPTED BY LARIMER COUNTY, CITY OF LOVELAND, CITY OF FORT COLLINS PAGE E-1-FC/LAR-2 FLOODING, STRUCTURAL DAMAGE OR OTHER DAMAGE UNLESS SUCH DAMAGE OR INJURIES ARE SUSTAINED AS A RESULT OF THE LOCAL ENTITY FAILURE TO PROPERLY MAINTAIN ITS WATER, WASTEWATER, AND/OR STORM DRAINAGE FACILITIES IN THE DEVELOPMENT. 19. ALL RECOMMENDATIONS OF THE FINAL DRAINAGE REPORT FORT COLLINS JEEP DEALERSHIP BY PARAGON ENGINEERING DATED MAY 26, 2017 AND EROSION AND SEDIMENT CONTROL ASSOCIATED WITH CONSTRUCTION ACTIVITIES FOR FORT COLLINS JEEP DEALERSHIP BY PARAGON ENGINEERING DATED AUGUST 29, 2017 SHALL BE FOLLOWED AND IMPLEMENTED. 20. TEMPORARY EROSION CONTROL DURING CONSTRUCTION SHALL BE PROVIDED AS SHOWN ON THE EROSION CONTROL PLAN. ALL EROSION CONTROL MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE DEVELOPER, UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS IS STABILIZED WITH HARD SURFACE OR LANDSCAPING. 21. THE DEVELOPER SHALL BE RESPONSIBLE FOR INSURING THAT NO MUD OR DEBRIS SHALL BE TRACKED ONTO THE EXISTING PUBLIC STREET SYSTEM. MUD AND DEBRIS MUST BE REMOVED WITHIN 24 HOURS BY AN APPROPRIATE MECHANICAL METHOD (I.E. MACHINE BROOM SWEEP, LIGHT DUTY FRONT-END LOADER, ETC.) OR AS APPROVED BY THE LOCAL ENTITY STREET INSPECTOR. 22. NO WORK MAY COMMENCE WITHIN ANY IMPROVED OR UNIMPROVED PUBLIC RIGHT-OF-WAY UNTIL A RIGHT-OF-WAY PERMIT OR DEVELOPMENT CONSTRUCTION PERMIT IS OBTAINED, IF APPLICABLE. 23. THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FOR ALL APPLICABLE AGENCIES PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DEVELOPER SHALL NOTIFY THE LOCAL ENTITY ENGINEERING INSPECTOR (FORT COLLINS - 221-6605) AND THE LOCAL ENTITY EROSION CONTROL INSPECTOR (FORT COLLINS – 221-6700) AT LEAST 2 WORKING DAYS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY, OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS. IF THE LOCAL ENTITY ENGINEER IS NOT AVAILABLE AFTER PROPER NOTICE OF CONSTRUCTION ACTIVITY HAS BEEN PROVIDED, THE DEVELOPER MAY COMMENCE WORK IN THE ENGINEER ABSENCE. HOWEVER, THE LOCAL ENTITY RESERVES THE RIGHT NOT TO ACCEPT THE IMPROVEMENT IF SUBSEQUENT TESTING REVEALS AN IMPROPER INSTALLATION. REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE FORT COLLINS JEEP CONSTRUCTION NOTES TWD 11/20/2017 1" = 30' JLC 16-018 C-2 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 1. THE EROSION CONTROL INSPECTOR MUST BE NOTIFIED AT LEAST TWENTY-FOUR (24) HOURS PRIOR TO ANY CONSTRUCTION ON THIS SITE. 2. THERE SHALL BE NO EARTH-DISTURBING ACTIVITY OUTSIDE THE LIMITS DESIGNATED ON THE ACCEPTED PLANS. 3. ALL REQUIRED PERIMETER SILT AND CONSTRUCTION FENCING SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBING ACTIVITY (STOCKPILING, STRIPPING, GRADING, ETC). ALL OTHER REQUIRED EROSION CONTROL MEASURES SHALL BE INSTALLED AT THE APPROPRIATE TIME IN THE CONSTRUCTION SEQUENCE AS INDICATED IN THE APPROVED PROJECT SCHEDULE, CONSTRUCTION PLANS, AND EROSION CONTROL REPORT. 4. AT ALL TIMES DURING CONSTRUCTION, THE DEVELOPER SHALL BE RESPONSIBLE FOR PREVENTING AND CONTROLLING ON-SITE EROSION INCLUDING KEEPING THE PROPERTY SUFFICIENTLY WATERED SO AS TO MINIMIZE WIND BLOWN SEDIMENT. THE DEVELOPER SHALL ALSO BE RESPONSIBLE FOR INSTALLING AND MAINTAINING ALL EROSION CONTROL FACILITIES SHOWN HEREIN. 5. PRE-DISTURBANCE VEGETATION SHALL BE PROTECTED AND RETAINED WHEREVER POSSIBLE. REMOVAL OR DISTURBANCE OF EXISTING VEGETATION SHALL BE LIMITED TO THE AREA(S) REQUIRED FOR IMMEDIATE CONSTRUCTION OPERATIONS, AND FOR THE SHORTEST PRACTICAL PERIOD OF TIME. 6. ALL SOILS EXPOSED DURING LAND DISTURBING ACTIVITY (STRIPPING, GRADING, UTILITY INSTALLATIONS, STOCKPILING, FILLING, ETC.) SHALL BE KEPT IN A ROUGHENED CONDITION BY RIPPING OR DISKING ALONG LAND CONTOURS UNTIL MULCH, VEGETATION, OR OTHER PERMANENT EROSION CONTROL BMPS ARE INSTALLED. NO SOILS IN AREAS OUTSIDE PROJECT STREET RIGHTS-OF-WAY SHALL REMAIN EXPOSED BY LAND DISTURBING ACTIVITY FOR MORE THAN THIRTY (30) DAYS BEFORE REQUIRED TEMPORARY OR PERMANENT EROSION CONTROL (E.G. SEED/MULCH, LANDSCAPING, ETC.) IS INSTALLED, UNLESS OTHERWISE APPROVED BY THE LOCAL ENTITY. 7. IN ORDER TO MINIMIZE EROSION POTENTIAL, ALL TEMPORARY (STRUCTURAL) EROSION CONTROL MEASURES SHALL: A. BE INSPECTED AT A MINIMUM OF ONCE EVERY TWO (2) WEEKS AND AFTER EACH SIGNIFICANT STORM EVENT AND REPAIRED OR RECONSTRUCTED AS NECESSARY IN ORDER TO ENSURE THE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. B. REMAIN IN PLACE UNTIL SUCH TIME AS ALL THE SURROUNDING DISTURBED AREAS ARE SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. C. BE REMOVED AFTER THE SITE HAS BEEN SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. 8. WHEN TEMPORARY EROSION CONTROL MEASURES ARE REMOVED, THE DEVELOPER SHALL BE RESPONSIBLE FOR THE CLEAN UP AND REMOVAL OF ALL SEDIMENT AND DEBRIS FROM ALL DRAINAGE INFRASTRUCTURE AND OTHER PUBLIC FACILITIES. 9. THE CONTRACTOR SHALL CLEAN UP ANY INADVERTENT DEPOSITED MATERIAL IMMEDIATELY AND MAKE SURE STREETS ARE FREE OF ALL MATERIALS BY THE END OF EACH WORKING DAY. 10. ALL RETAINED SEDIMENTS, PARTICULARLY THOSE ON PAVED ROADWAY SURFACES, SHALL BE REMOVED AND DISPOSED OF IN A MANNER AND LOCATION SO AS NOT TO CAUSE THEIR RELEASE INTO ANY WATERS OF THE UNITED STATES. 11. NO SOIL STOCKPILE SHALL EXCEED TEN (10) FEET IN HEIGHT. ALL SOIL STOCKPILES SHALL BE PROTECTED FROM SEDIMENT TRANSPORT BY SURFACE ROUGHENING, WATERING, AND PERIMETER SILT FENCING. ANY SOIL STOCKPILE REMAINING AFTER THIRTY (30) DAYS SHALL BE SEEDED AND MULCHED. 12. THE STORMWATER VOLUME CAPACITY OF DETENTION PONDS WILL BE RESTORED AND STORM SEWER LINES WILL BE CLEANED UPON COMPLETION OF THE PROJECT AND BEFORE TURNING THE MAINTENANCE OVER TO THE LOCAL ENTITY OR HOMEOWNERS ASSOCIATION (HOA). 13. CITY ORDINANCE AND COLORADO DISCHARGE PERMIT SYSTEM (CDPS) REQUIREMENTS MAKE IT UNLAWFUL TO DISCHARGE OR ALLOW THE DISCHARGE OF ANY POLLUTANT OR CONTAMINATED WATER FROM CONSTRUCTION SITES. POLLUTANTS INCLUDE, BUT ARE NOT LIMITED TO DISCARDED BUILDING MATERIALS, CONCRETE TRUCK WASHOUT, CHEMICALS, OIL AND GAS PRODUCTS, LITTER, AND SANITARY WASTE. THE DEVELOPER SHALL AT ALL TIMES TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THE PROPER CONTAINMENT AND DISPOSAL OF POLLUTANTS ON THE SITE IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. 14. A DESIGNATED AREA SHALL BE PROVIDED ON SITE FOR CONCRETE TRUCK CHUTE WASHOUT. THE AREA SHALL BE CONSTRUCTED SO AS TO CONTAIN WASHOUT MATERIAL AND LOCATED AT LEAST FIFTY (50) FEET AWAY FROM ANY WATERWAY DURING CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION ACTIVITIES THE CONCRETE WASHOUT MATERIAL WILL BE REMOVED AND PROPERLY DISPOSED OF PRIOR TO THE AREA BEING RESTORED. 15. TO ENSURE THAT SEDIMENT DOES NOT MOVE OFF OF INDIVIDUAL LOTS ONE OR MORE OF THE FOLLOWING SEDIMENT/EROSION CONTROL BMPS SHALL BE INSTALLED AND MAINTAINED UNTIL THE LOTS ARE SUFFICIENTLY STABILIZED, AS DETERMINED BY THE EROSION CONTROL INSPECTOR, (WITHIN LOVELAND GMA AND CITY LIMITS ONLY). A. BELOW ALL GUTTER DOWNSPOUTS. B. OUT TO DRAINAGE SWALES. C. ALONG LOT PERIMETER. D. OTHER LOCATIONS, IF NEEDED. 16. CONDITIONS IN THE FIELD MAY WARRANT EROSION CONTROL MEASURES IN ADDITION TO WHAT IS SHOWN ON THESE PLANS. THE DEVELOPER SHALL IMPLEMENT WHATEVER MEASURES ARE DETERMINED NECESSARY, AS DIRECTED BY THE CITY/COUNTY. 17. A VEHICLE TRACKING CONTROL PAD SHALL BE INSTALLED WHEN NEEDED FOR CONSTRUCTION EQUIPMENT, INCLUDING BUT NOT LIMITED TO PERSONAL VEHICLES EXITING EXISTING ROADWAYS. NO EARTHEN MATERIALS, I.E. STONE, DIRT, ETC. SHALL BE PLACED IN THE CURB & GUTTER OR ROADWAY AS A RAMP TO ACCESS TEMPORARY STOCKPILES, STAGING AREAS, CONSTRUCTION MATERIALS, CONCRETE WASHOUT AREAS, AND/OR BUILDING SITES. 18. ADD NOTES TO REFLECT THE STORMWATER RUNOFF CONTROL PLAN OF THE INDIVIDUAL DEVELOPMENT. 24. THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING SOILS TESTS WITHIN THE PUBLIC RIGHT-OF-WAY AFTER STANDARD EROSION AND SEDIMENT CONTROL NOTES: RIGHT OF WAY GRADING AND ALL UTILITY TRENCH WORK IS COMPLETE AND PRIOR TO THE PLACEMENT OF CURB, GUTTER, SIDEWALK AND PAVEMENT. IF THE FINAL SOILS/PAVEMENT DESIGN REPORT DOES NOT CORRESPOND WITH THE RESULTS OF THE ORIGINAL GEOTECHNICAL REPORT, THE DEVELOPER SHALL BE RESPONSIBLE FOR A RE-DESIGN OF THE SUBJECT PAVEMENT SECTION OR, THE DEVELOPER MAY USE THE LOCAL ENTITY’S DEFAULT PAVEMENT THICKNESS SECTION(S). REGARDLESS OF THE OPTION USED, ALL FINAL SOILS/PAVEMENT DESIGN REPORTS SHALL BE PREPARED BY A LICENSED PROFESSIONAL ENGINEER. THE FINAL REPORT SHALL BE SUBMITTED TO THE INSPECTOR A MINIMUM OF 10 WORKING DAYS PRIOR TO PLACEMENT OF BASE AND ASPHALT. PLACEMENT OF CURB, GUTTER, SIDEWALK, BASE AND ASPHALT SHALL NOT OCCUR UNTIL THE LOCAL ENTITY ENGINEER APPROVES THE FINAL REPORT. 25. THE CONTRACTOR SHALL HIRE A LICENSED ENGINEER OR LAND SURVEYOR TO SURVEY THE CONSTRUCTED ELEVATIONS OF THE STREET SUBGRADE AND THE GUTTER FLOWLINE AT ALL INTERSECTIONS, INLETS, AND OTHER LOCATIONS REQUESTED BY THE LOCAL ENTITY INSPECTOR. THE ENGINEER OR SURVEYOR MUST CERTIFY IN A LETTER TO THE LOCAL ENTITY THAT THESE ELEVATIONS CONFORM TO THE APPROVED PLANS AND SPECIFICATIONS. ANY DEVIATIONS SHALL BE NOTED IN THE LETTER AND THEN RESOLVED WITH THE LOCAL ENTITY BEFORE INSTALLATION OF BASE COURSE OR ASPHALT WILL BE ALLOWED ON THE STREETS. 26. ALL UTILITY INSTALLATIONS WITHIN OR ACROSS THE ROADBED OF NEW RESIDENTIAL ROADS MUST BE COMPLETED PRIOR TO THE FINAL STAGES OF ROAD CONSTRUCTION. FOR THE PURPOSES OF THESE STANDARDS, ANY WORK EXCEPT C/G ABOVE THE SUBGRADE IS CONSIDERED FINAL STAGE WORK. ALL SERVICE LINES MUST BE STUBBED TO THE PROPERTY LINES AND MARKED SO AS TO REDUCE THE EXCAVATION NECESSARY FOR BUILDING CONNECTIONS. 27. PORTIONS OF LARIMER COUNTY ARE WITHIN OVERLAY DISTRICTS. THE LARIMER COUNTY FLOODPLAIN RESOLUTION SHOULD BE REFERRED TO FOR ADDITIONAL CRITERIA FOR ROADS WITHIN THESE DISTRICTS. 28. ALL ROAD CONSTRUCTION IN AREAS DESIGNATED AS WILD FIRE HAZARD AREAS SHALL BE DONE IN ACCORDANCE WITH THE CONSTRUCTION CRITERIA AS ESTABLISHED IN THE WILD FIRE HAZARD AREA MITIGATION REGULATIONS IN FORCE AT THE TIME OF FINAL PLAT APPROVAL. 29. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION, THE CONTRACTOR SHALL CONTACT THE LOCAL ENTITY FORESTER TO SCHEDULE A SITE INSPECTION FOR ANY TREE REMOVAL REQUIRING A PERMIT. 30. THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO, EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY. REFER TO OSHA PUBLICATION 2226, EXCAVATING AND TRENCHING. 31. THE DEVELOPER SHALL SUBMIT A CONSTRUCTION TRAFFIC CONTROL PLAN, IN ACCORDANCE WITH MUTCD, TO THE APPROPRIATE RIGHT-OF-WAY AUTHORITY. (LOCAL ENTITY, COUNTY OR STATE), FOR APPROVAL, PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN, OR AFFECTING, THE RIGHT-OF-WAY. THE DEVELOPER SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY THE CONSTRUCTION ACTIVITIES. 32. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION THAT WILL AFFECT TRAFFIC SIGNS OF ANY TYPE, THE CONTRACTOR SHALL CONTACT LOCAL ENTITY TRAFFIC OPERATIONS DEPARTMENT, WHO WILL TEMPORARILY REMOVE OR RELOCATE THE SIGN AT NO COST TO THE CONTRACTOR; HOWEVER, IF THE CONTRACTOR MOVES THE TRAFFIC SIGN THEN THE CONTRACTOR WILL BE CHARGED FOR THE LABOR, MATERIALS AND EQUIPMENT TO REINSTALL THE SIGN AS NEEDED. 33. THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR THE INITIAL INSTALLATION OF TRAFFIC SIGNING AND STRIPING FOR THE DEVELOPMENT RELATED TO THE DEVELOPMENT’S LOCAL STREET OPERATIONS. IN ADDITION, THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR TRAFFIC SIGNING AND STRIPING RELATED TO DIRECTING TRAFFIC ACCESS TO AND FROM THE DEVELOPMENT. 34. THERE SHALL BE NO SITE CONSTRUCTION ACTIVITIES ON SATURDAYS, UNLESS SPECIFICALLY APPROVED BY THE LOCAL ENTITY ENGINEER, AND NO SITE CONSTRUCTION ACTIVITIES ON SUNDAYS OR HOLIDAYS, UNLESS THERE IS PRIOR WRITTEN APPROVAL BY THE LOCAL ENTITY. 35. THE DEVELOPER IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS, SHOWN ON THESE DRAWINGS, OR DESIGNATED TO BE PROVIDED, INSTALLED, OR CONSTRUCTED, UNLESS SPECIFICALLY NOTED OTHERWISE. 36. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. IF PERTINENT DIMENSIONS ARE NOT SHOWN, CONTACT THE DESIGNER FOR CLARIFICATION, AND ANNOTATE THE DIMENSION ON THE AS-BUILT RECORD DRAWINGS. 37 THE DEVELOPER SHALL HAVE, ONSITE AT ALL TIMES, ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB. 38. IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE DEVELOPER SHALL CONTACT THE DESIGNER AND THE LOCAL ENTITY ENGINEER IMMEDIATELY. 39. THE DEVELOPER SHALL BE RESPONSIBLE FOR RECORDING AS-BUILT INFORMATION ON A SET OF RECORD DRAWINGS KEPT ON THE CONSTRUCTION SITE, AND AVAILABLE TO THE LOCAL ENTITY’S INSPECTOR AT ALL TIMES. UPON COMPLETION OF THE WORK, THE CONTRACTOR(S) SHALL SUBMIT RECORD DRAWINGS TO THE LOCAL ENTITY ENGINEER. 40. THE DESIGNER SHALL PROVIDE, IN THIS LOCATION ON THE PLAN, THE LOCATION AND DESCRIPTION OF THE NEAREST SURVEY BENCHMARKS (2) FOR THE PROJECT AS WELL AS THE BASIS OF BEARINGS. THE INFORMATION SHALL BE AS FOLLOWS: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' 41. ALL STATIONING IS BASED ON FLOWLINE OF ROADWAYS UNLESS OTHERWISE NOTED. 42. DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS EXISTING FENCES, TREES, STREETS, SIDEWALKS, CURBS AND GUTTERS, LANDSCAPING, STRUCTURES, AND IMPROVEMENTS DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED IN LIKE KIND AT THE DEVELOPER’S EXPENSE, UNLESS OTHERWISE INDICATED ON THESE PLANS, PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 43. WHEN AN EXISTING ASPHALT STREET MUST BE CUT, THE STREET MUST BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ITS ORIGINAL CONDITION. THE EXISTING STREET CONDITION SHALL BE DOCUMENTED BY THE LOCAL ENTITY CONSTRUCTION INSPECTOR BEFORE ANY CUTS ARE MADE. PATCHING SHALL BE DONE IN ACCORDANCE WITH THE LOCAL ENTITY STREET REPAIR STANDARDS. THE FINISHED PATCH SHALL BLEND IN SMOOTHLY INTO THE EXISTING SURFACE. ALL LARGE PATCHES SHALL BE PAVED WITH AN ASPHALT LAY-DOWN MACHINE. IN STREETS WHERE MORE THAN ONE CUT IS MADE, AN OVERLAY OF THE ENTIRE STREET WIDTH, INCLUDING THE PATCHED AREA, MAY BE REQUIRED. THE DETERMINATION OF NEED FOR A COMPLETE OVERLAY SHALL BE MADE BY THE LOCAL ENTITY ENGINEER AND/OR THE LOCAL ENTITY INSPECTOR AT THE TIME THE CUTS ARE MADE. 44. UPON COMPLETION OF CONSTRUCTION, THE SITE SHALL BE CLEANED AND RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED BEFORE CONSTRUCTION, OR TO THE GRADES AND CONDITION AS REQUIRED BY THESE PLANS. 45. STANDARD HANDICAP RAMPS ARE TO BE CONSTRUCTED AT ALL CURB RETURNS AND AT ALL “T” INTERSECTIONS. 46. AFTER ACCEPTANCE BY THE LOCAL ENTITY, PUBLIC IMPROVEMENTS DEPICTED IN THESE PLANS SHALL BE GUARANTEED TO BE FREE FROM MATERIAL AND WORKMANSHIP DEFECTS FOR A MINIMUM PERIOD OF TWO YEARS FROM THE DATE OF ACCEPTANCE. 47. DELETED 48. VARIANCES ARE LISTED AS FOLLOWS: PDP170013 VARIANCE REQUEST FOR LCUASS FIGURE 19-6 PDP170013 VARIANCE REQUEST FOR LCUASS TABLE 7-3 1. ALL STREET CONSTRUCTION IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF THESE PLANS AS WELL AS THE STREET IMPROVEMENTS NOTES LISTED HERE. 2. A PAVING SECTION DESIGN, SIGNED AND STAMPED BY A COLORADO LICENSED ENGINEER, MUST BE SUBMITTED TO THE LOCAL ENTITY ENGINEER FOR APPROVAL, PRIOR TO ANY STREET CONSTRUCTION ACTIVITY, (FULL DEPTH ASPHALT SECTIONS ARE NOT PERMITTED AT A DEPTH GREATER THAN 8 INCHES OF ASPHALT). THE JOB MIX SHALL BE SUBMITTED FOR APPROVAL PRIOR TO PLACEMENT OF ANY ASPHALT. 3. WHERE PROPOSED PAVING ADJOINS EXISTING ASPHALT, THE EXISTING ASPHALT SHALL BE SAW CUT, A MINIMUM DISTANCE OF 12 INCHES FROM THE EXISTING EDGE, TO CREATE A CLEAN CONSTRUCTION JOINT. THE DEVELOPER SHALL BE REQUIRED TO REMOVE EXISTING PAVEMENT TO A DISTANCE WHERE A CLEAN CONSTRUCTION JOINT CAN BE MADE. WHEEL CUTS SHALL NOT BE ALLOWED UNLESS APPROVED BY THE LOCAL ENTITY ENGINEER IN LOVELAND. 4. STREET SUBGRADES SHALL BE SCARIFIED THE TOP 12 INCHES AND RE-COMPACTED PRIOR TO SUBBASE INSTALLATION. NO BASE MATERIAL SHALL BE LAID UNTIL THE SUBGRADE HAS BEEN INSPECTED AND APPROVED BY THE LOCAL ENTITY ENGINEER. 5. FT. COLLINS ONLY. VALVE BOXES AND MANHOLES ARE TO BE BROUGHT UP TO GRADE AT THE TIME OF PAVEMENT PLACEMENT OR OVERLAY. VALVE BOX ADJUSTING RINGS ARE NOT ALLOWED. 6. WHEN AN EXISTING ASPHALT STREET MUST BE CUT, THE STREET MUST BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ITS ORIGINAL CONDITION. THE EXISTING STREET CONDITION SHALL BE DOCUMENTED BY THE INSPECTOR BEFORE ANY CUTS ARE MADE. CUTTING AND PATCHING SHALL BE DONE IN CONFORMANCE WITH CHAPTER 25, RECONSTRUCTION AND REPAIR. THE FINISHED PATCH SHALL BLEND SMOOTHLY INTO THE EXISTING SURFACE. THE DETERMINATION OF NEED FOR A COMPLETE OVERLAY SHALL BE MADE BY THE LOCAL ENTITY ENGINEER. ALL OVERLAY WORK SHALL BE COORDINATED WITH ADJACENT LANDOWNERS SUCH THAT FUTURE PROJECTS DO NOT CUT THE NEW ASPHALT OVERLAY WORK. 7. ALL TRAFFIC CONTROL DEVICES SHALL BE IN CONFORMANCE WITH THESE PLANS OR AS OTHERWISE SPECIFIED IN M.U.T.C.D. (INCLUDING COLORADO SUPPLEMENT) AND AS PER THE RIGHT-OF-WAY WORK PERMIT TRAFFIC CONTROL PLAN. 8. THE DEVELOPER IS REQUIRED TO PERFORM A GUTTER WATER FLOW TEST IN THE PRESENCE OF THE LOCAL ENTITY INSPECTOR AND PRIOR TO INSTALLATION OF ASPHALT. GUTTERS THAT HOLD MORE THAN ¼ INCH DEEP OR 5 FEET LONGITUDINALLY, OF WATER, SHALL BE COMPLETELY REMOVED AND RECONSTRUCTED TO DRAIN PROPERLY. 9. PRIOR TO PLACEMENT OF H.B.P. OR CONCRETE WITHIN THE STREET AND AFTER MOISTURE/DENSITY TESTS HAVE BEEN TAKEN ON THE SUBGRADE MATERIAL (WHEN A FULL DEPTH SECTION IS PROPOSED) OR ON THE SUBGRADE AND BASE MATERIAL (WHEN A COMPOSITE SECTION IS PROPOSED), A MECHANICAL "PROOF ROLL" WILL BE REQUIRED. THE ENTIRE SUBGRADE AND/OR BASE MATERIAL SHALL BE ROLLED WITH A HEAVILY LOADED VEHICLE HAVING A TOTAL GVW OF NOT LESS THAN 50,000 LBS. AND A SINGLE AXLE WEIGHT OF AT LEAST 18,000 LBS. WITH PNEUMATIC TIRES INFLATED TO NOT LESS THAT 90 P.S.I.G. “PROOF ROLL” VEHICLES SHALL NOT TRAVEL AT SPEEDS GREATER THAN 3 M.P.H. ANY PORTION OF THE SUBGRADE OR BASE MATERIAL WHICH EXHIBITS EXCESSIVE PUMPING OR DEFORMATION, AS DETERMINED BY THE LOCAL ENTITY ENGINEER, SHALL BE REWORKED, REPLACED OR OTHERWISE MODIFIED TO FORM A SMOOTH, NON-YIELDING SURFACE. THE LOCAL ENTITY ENGINEER SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO THE “PROOF ROLL.” ALL “PROOF ROLLS” SHALL BE PREFORMED IN THE PRESENCE OF AN INSPECTOR. STREET IMPROVEMENT NOTES: CURB & GUTTER 12' 60' REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE VICINITY MAP NOT TO SCALE OWNER/DEVELOPER: COMMERCIAL BUILDING SERVICES 7561 S. GRANT STREET, SUITE A-4 LITTLETON, COLORADO 80122 PHONE: (303) 730-3001 CONTACT: STEVE MOORE ENGINEER / PLAN PREPARER: PARAGON ENGINEERING CONSULTANTS, INC. 7852 S. ELATI STREET, SUITE 106 LITTLETON, COLORADO 80120 PHONE: (303) 794-8604 FAX: (303) 795-3072 CONTACT: TROY DENNING, P.E. CONTACTS: CIVIL ENGINEER'S STATEMENT I, TROY W. DENNING, BEING A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF COLORADO, HEREBY ATTEST THAT ALL GRADING, UTILITY AND DRAINAGE IMPROVEMENTS IDENTIFIED ON THESE UTILITY PLANS HAVE BEEN DESIGNATED AND ENGINEERED IN CONFORMANCE WITH ALL CITY OF FORT COLLINS PUBLIC WORKS CONSTRUCTION STANDARDS. . . TROY W. DENNING P.E. 34200 DATE PARAGON ENGINEERING CONSULTANTS, INC. SITE LEGAL DESCRIPTION: A PARCEL OF LAND LOCATED IN THE SOUTHEAST ONE-QUARTER OF SECTION 35, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHEAST CORNER OF SAID SOUTHEAST ONE-QUARTER AND CONSIDERING THE SOUTH LINE OF SAID SOUTHEAST ONE-QUARTER TO BEAR N89°53'00”W; THENCE N89°53'00”W, ALONG SAID SOUTH LINE, A DISTANCE OF 967.13 FEET; THENCE N1°05'37”E A DISTANCE OF 50.00 FEET TO THE POINT OF BEGINNING ON THE NORTHERLY RIGHT-OF-WAY LINE OF WEST HARMONY ROAD; THENCE ALONG THE EASTERLY LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20120033213 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER, THE FOLLOWING SEVEN (7) COURSES: 1. N1°05'37”E A DISTANCE OF 224.10 FEET; 2. N89°58'15”W A DISTANCE OF 5.00 FEET; 3. N1°05'37”E A DISTANCE OF 81.29 FEET; 4. N88°54'23”W A DISTANCE OF 5.00 FEET TO A POINT OF NON-TANGENT CURVE; 5. NORTHWESTERLY, ALONG THE ARC OF SAID CURVE TO THE LEFT, HAVING A CENTRAL ANGLE OF 28°33'29”, A RADIUS OF 150.50 FEET, AN ARC LENGTH OF 75.01 FEET AND A CHORD BEARING AND DISTANCE OF N12°44'40”W, 74.24 FEET TO A POINT OF REVERSE CURVE; 6. NORTHWESTERLY, ALONG THE ARC OF SAID CURVE TO THE RIGHT, HAVING A CENTRAL ANGLE OF 20°00'08”, A RADIUS OF 99.50 FEET, AN ARC LENGTH OF 34.74 FEET AND A CHORD BEARING AND DISTANCE OF N17°01'11”W, 34.56 FEET; 7. N1°05'37”E A DISTANCE OF 70.00 FEET TO THE SOUTH LINE OF LOT 1, PEDERSON AUTO PLAZA SUBDIVISION; THENCE S89°48'40”E, ALONG SAID SOUTH LINE, A DISTANCE OF 435.54 FEET TO THE WESTERLY RIGHT-OF-WAY LINE OF SOUTH MASON STREET; THENCE S1°03'05”W, ALONG SAID WESTERLY LINE, A DISTANCE OF 462.10 FEET TO THE NORTHWESTERLY LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20100010805 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER; THENCE S43°16'52”W, ALONG SAID NORTHWESTERLY LINE, A DISTANCE OF 20.21 FEET TO THE NORTH LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20100015829 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER AND SAID NORTHERLY RIGHT-OF-WAY LINE OF WEST HARMONY ROAD; THENCE ALONG SAID LINE THE FOLLOWING THREE (3) COURSES: 1. N89°53'01”W A DISTANCE OF 280.33 FEET; 2. S73°53'58”W A DISTANCE OF 12.50 FEET; 3. N89°53'00”W A DISTANCE OF 91.54 FEET TO THE POINT OF BEGINNING. CONTAINING 195,092 SQUARE FEET OR 4.479 ACRES OF LAND, MORE OR LESS. BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGNS, REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS. THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BE THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. EXISTING UTILITIES SHOWN ON THESE IMPROVEMENT PLANS ARE APPROXIMATE ONLY. THEY HAVE BEEN LOCATED FROM FIELD SURVEYS AND UTILITY RECORDS. THE CONTRACTOR SHALL CONTACT ALL RESPECTIVE UTILITY COMPANIES TO HAVE ALL UTILITIES FIELD LOCATED PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONS TO PROTECT ALL EXISTING UTILITIES ENCOUNTERED, AND SHALL BE RESPONSIBLE FOR THE IMMEDIATE REPAIR OF ALL UTILITIES DAMAGED DURING CONSTRUCTION WHETHER SHOWN ON THESE PLANS OR NOT. IT SHALL BE THE CONTRACTOR'S FULL RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL EXISTING STRUCTURES AND UTILITIES SHOWN ON THESE IMPROVEMENT PLANS, TO ASCERTAIN WHETHER ANY STRUCTURES AND UTILITIES MAY EXIST, AND TO REPAIR OR REPLACE ANY STRUCTURES AND UTILITIES THAT MIGHT BE DAMAGED. IF ANY UNKNOWN SUBSURFACE STRUCTURES OR UTILITIES ARE ENCOUNTERED DURING CONSTRUCTION, IT SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CIVIL ENGINEER WHOSE NAME APPEARS ON THESE PLANS. FORT COLLINS JEEP COVER SHEET TWD 03/15/2017 N/A JLC 16-018 C-1 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 EXISTING UTILITIES DISCLAIMER : BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). SHEET INDEX Sheet Number Sheet Title C-1 COVER SHEET C-2 CONSTRUCTION NOTES C-3 CONSTRUCTION NOTES C-4 DEMOLITION PLAN C-5 GRADING PLAN C-6 EROSION CONTROL PLAN C-7 OVERALL UTILITY PLAN C-8 MASON STREET WIDENING PLAN C-9.1 MASON STREET CROSS SECTIONS C-9.2 MASON STREET CROSS SECTIONS C-10 BUS STOP PLAN C-11 ROADWAY SIGNAGE & STRIPING PLAN C-12 FIRE LANE SIGNAGE & STRIPING PLAN C-13 DETAILS C-14 DETAILS C-15 DETAILS C-16 DETAILS C-17 DETAILS C-18 DETAILS C-19 DRAINAGE PLAN FORT COLLINS JEEP UTILITY PLANS FOR LOCATED IN THE SOUTHEAST ONE-QUARTER OF SECTION 35, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO OCTOBER, 2017