HomeMy WebLinkAboutFTC CHIPPERS SC WTE VERIZON PDP - PDP170027 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC CHIPPERS SC
3517 S MASON ST
FT. COLLINS, COLORADO 80525
SMALL CELL
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
DEPART 3131 S VAUGHN WAY, AURORA, CO 80014:
HEAD SOUTH TOWARD S VAUGHN WAY. TURN RIGHT ONTO S VAUGHN WAY. TURN LEFT TO MERGE
ONTO CO-83 N TOWARD INTERSTATE 225. MERGE ONTO CO-83 N. USE THE RIGHT 3 LANES TO
TAKE THE INTERSTATE 225 S EXIT. MERGE ONTO I-225 S. USE THE RIGHT 2 LANES TO TAKE EXIT 1B
FOR INTERSTATE 25 N TOWARD FT. COLLINS. KEEP RIGHT AND MERGE ONTO I-25 N. CONTINUE ON
I-25 N TOWARDS FORT COLLINS. TAKE EXIT 265 FOR HARMONY RD. TURN LEFT ONTO E HARMONY
RD. CONTINUE ON HARMONY TO ZIEGLER RD. TURN RIGHT ON ZIEGLER RD. AT THE TRAFFIC
CIRCLE TAKE THE 3RD EXIT ONTO E. HORSETOOTH RD. CONTINUE ON HORSETOOTH RD TO
McCLELLAND DR. TURN RIGHT ON McCLELLAND DR. DESTINATION WILL BE ON THE RIGHT IN
PARKING LOT
FT. COLLINS, COLORADO
CLIENT
PROPERTY OWNER
JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 66211
PHONE: 913-344-2030
BLACO INVESTMENTS LLC
CONTACT: KATHRYN FOX
PHONE: 970-227-3381
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JASON SHELLEDY
PHONE: 970-646-1283
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
1196 GRANT STREET, UNIT 313
DENVER, CO 80203
CONTACT: RYAN SAGAR
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: Ram.Nandiraju@verizonwireless.com
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2012 (W/ LOCAL AMENDMENTS)
NEC 2014
NFPA-1 (2006)
U - UTILITY
IIB
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
PHOTOSIMULATION
VIEWS
PH-1
2
2
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING EAST)
N.T.S.
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST)
N.T.S.
ET
UGE
UGE
UGE UGE UGE UGE UGE UGE UGE UGE
UGE
UGE
UGE UGE
T T T T T T T T
T
T T T T
T T T T
T T
T T T T T T
T T T T T T T T T T
T T T
AC
AC
AC
S
S
S
EV
ET
X X X X
X X X X
F F F
E E E
UGE UGE UGE UGE UGE
(E) 6' UTILITY EASEMENT
(E) 10' DRAINAGE EASEMENT
(E) 10' UTILITY EASEMENT
41'-2"
T
HIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
1
Z-1
SITE PLAN
SCALE: 1"=30'-0"
1 inch = 30ft.
( IN FEET )
GRAPHIC SCALE
15 0 7.5 15 30 60
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
UGE
UGE UGE UGE
UGE UGE UGE UGE
UGE
UGE UGE
T T T T T
T T T T
T T T T T T T T T T T T T T
T T T T T T T T T T
T T
ET
X
F F F F F F F F
F
E E E E E E E E E
E
F
UGE
UGE UGE UGE UGE UGE UGE UGE U
GE UGE UGE UGE UGE UGE UGE
E E
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES,
LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER
PUBLIC AUTHORITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND
INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR
MUNICIPAL AUTHORITIES.
3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF
ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR
PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS
SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL
INTENT OF THESE DRAWINGS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE
IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR
SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS
FACILITY.
5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL
MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL
EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS.
6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO
VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS.
7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN
STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED.
8. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO
HANDICAP ACCESS REQUIRED).
10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR
SANITARY SERVICE.
11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER.
12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF
ENGINEERING PRIOR TO INSTALLATION.
13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET EIA/TIA-222-G AS PER IBC 2012
REQUIREMENTS.
14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL.
15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR
TO EXCAVATING.
16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT
UGE UGE UGE UGE UGE UGE
F F F F F F F
F F
E E E E E E E E
E E E
UGE UGE
UGE UGE UGE UGE UGE UGE UGE U
GE UGE UGE UGE UGE UGE
10'-0"
10'-0"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
1
Z-3
PROPOSED EQUIPMENT DETAIL
SCALE: 3/16"=1'-0"
EQUIPMENT
PLAN
EXISTING
CURB
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
35'-0"
30'-0"
35'-0"
33'-3"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
2
Z-4
PROPOSED ELEVATION - LOOKING EAST
SCALE: 3/32"=1'-0"
GRADE
0'-0" AGL
1
Z-4
EXISTING ELEVATION - LOOKING EAST
SCALE: 3/32"=1'-0"
3/32 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
0 2 4 8 12 16 20
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
2
ELEVATIONS
Z-4
6
TOP OF PROPOSED LIGHT
30'-0" AGL
TOP OF EXISTING LIGHT POLE
35'-0" AGL
GRADE
0'-0" AGL
EXISTING LANDSCAPING
EXISTING (TYP)
BUILDING
TOP OF PROPOSED POLE
35'-0" AGL
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
UGE
UGE
UGE UGE UGE UGE UGE
UGE
UGE
UGE UGE
T T
T
T T T T T T T T
T T
T T T T T T
T T T T T
T T T T T
T T T
S
S
S
EV
ET
X X X X
X X X X
UGE UGE UGE UGE UGE
(E) 10' UTILITY EASEMENT
U
GE
UGE
UGE UGE UGE UGE UGE
UGE
UGE
UGE UGE
T T
T
T T T T T T
T T
T T
T T T T T
T
T T T T T T T T T T
T T T
S
S
S
EV
ET
X X X X
X X X X
UGE UGE UGE UGE UGE
(E) 10' UTILITY EASEMENT
T
HIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
ET
AC
AC
AC
S
S
S
EV
ET
X X X X
X X X X
20'-0" PROPERTY
LINE OFFSET
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
1
PM-1
PHOTOMETRIC PLAN - EXISTING
SCALE: 1"=30'-0"
1 inch = 30ft.
( IN FEET )
GRAPHIC SCALE
15 0 7.5 15 30 60
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
ET
AC
AC
AC
S
S
S
EV
ET
X X X X
X X X X
20'-0" PROPERTY
LINE OFFSET
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
1
PM-1
PHOTOMETRRIC PLAN - PROPOSED
SCALE: 1"=30'-0"
1 inch = 30ft.
( IN FEET )
GRAPHIC SCALE
15 0 7.5 15 30 60
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
4'-10"
32'-0"
2'-2"
2'-2"
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
LINE DRAWING
LD-1
10
1
LD-1
METRO CELL LINE DRAWING
N.T.S.
ALL ASSOCIATED SERVICE
EQUIPMENT WITHIN POLE BASE
PROPOSED CONCEALED
QUASI OMNI ANTENNA
NOTE:
POLE TO BE PAINTED AND
TEXTURED TO MATCH
EXISTING LIGHT POLES
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
PHOTOMETRIC PLAN -
PROPOSED
PM-2
9
McCLELLAND DR
EXISTING
LANDSCAPING
(37'-2")
EXISTING
BUILDING
(16')
EXISTING
BUILDING
(15')
EXISTING
BUILDING
(17')
EXISTING
BUILDING
(18'-4")
EXISTING
LANDSCAPING
(35'-10")
EXISTING
LANDSCAPING
(31'-10")
REMOVE EXISTING LIGHT POLE AND INSTALL
NEW ALL-IN-ONE SMALL CELL POLE
(PAINTED AND TEXTURED TO MATCH
EXISTING LIGHT POLES)
EXISTING
LANDSCAPING
(35'-8")
EXISTING CURB
EXISTING PROPERTY LINE
EXISTING
LANDSCAPING
(35'-8")
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
PHOTOMETRIC PLAN -
EXISTING CONDITIONS
PM-1
8
McCLELLAND DR
EXISTING
LANDSCAPING
(37'-2")
EXISTING
BUILDING
(16')
EXISTING
BUILDING
(15')
EXISTING
BUILDING
(17')
EXISTING
BUILDING
(18'-4")
EXISTING
LANDSCAPING
(35'-10")
EXISTING
LANDSCAPING
(31'-10")
EXISTING
LANDSCAPING
(35'-8")
EXISTING CURB
EXISTING PROPERTY LINE
EXISTING
LANDSCAPING
(35'-8")
1
Z-5
LANDSCAPING PLAN - EXISTING
SCALE: 1"=30'-0"
1 inch = 30ft.
( IN FEET )
GRAPHIC SCALE
15 0 7.5 15 30 60
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
LANDSCAPING PLAN
Z-5
7
McCLELLAND DR
EXISTING
LANDSCAPING
(37'-2")
EXISTING
PARKING
LOT
EXISTING
LANDSCAPING
(35'-10")
EXISTING
LANDSCAPING
(31'-10")
EXISTING
LANDSCAPING
(35'-8")
EXISTING CURB
EXISTING PROPERTY LINE
EXISTING
LANDSCAPING
(35'-8")
McCLELLAND DR
EXISTING
LANDSCAPING
(37'-2")
EXISTING
PARKING
LOT
EXISTING
LANDSCAPING
(35'-10")
EXISTING
LANDSCAPING
(31'-10")
EXISTING
LANDSCAPING
(35'-8")
EXISTING CURB
EXISTING PROPERTY LINE
EXISTING
LANDSCAPING
(35'-8")
EXISTING
LIGHTPOLE
(TO BE REMOVED) REMOVE EXISTING LIGHT POLE AND
REPLACE WITH NEW ALL-IN-ONE
SMALL CELL POLE
(PAINTED AND TEXTURED TO MATCH
EXISTING LIGHT POLES)
EXISTING LANDSCAPING
(ANY DISTURBED OR REMOVED LANDSCAPING
WILL BE RELOCATED AND REPLACED
ELSEWHERE ON THE PROPERTY)
EXISTING LANDSCAPING
SHRUBS WITHIN ISLAND (TYP)
2
Z-5
LANDSCAPING PLAN - PROPOSED
SCALE: 1"=30'-0"
1 inch = 30ft.
( IN FEET )
GRAPHIC SCALE
15 0 7.5 15 30 60
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
EXISTING
BUILDING
EXISTING
LANDSCAPING
(TYP)
REMOVE EXISTING LIGHT POLE AND
REPLACE WITH NEW ALL-IN-ONE
SMALL CELL POLE
(PAINTED AND TEXTURED TO MATCH
EXISTING LIGHT POLES)
PROPOSED CONCEALED
QUASI OMNI ANTENNA
PROPOSED VERIZON RAD CENTER
33'-3" AGL
PROPOSED SLENDERFORM 48 LED,
240V LIGHTING
EXISTING LIGHT POLE
(TO BE REMOVED AND REPLACED)
EXISTING LANDSCAPING
(ANY DISTURBED OR REMOVED LANDSCAPING
WILL BE RELOCATED AND REPLACED
ELSEWHERE ON THE PROPERTY)
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
0 1 2 4 8
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
3/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1
5
Z-3
PROPOSED FIBER RUN FROM
FIBER VAULT TO EQUIPMENT SITE
PROPOSED POWER
RUN FROM EXISTING 150KVA
TRANSFORMER TO EQUIPMENT SITE
EXISTING UNDERGROUND
ELECTRIC
PROPOSED 10'x10' LEASE AREA
REMOVE EXISTING LIGHT POLE AND INSTALL
NEW ALL-IN-ONE SMALL CELL POLE
(PAINTED AND TEXTURED TO MATCH
EXISTING LIGHT POLES)
PROPOSED CONCEALED
QUASI OMNI ANTENNA
PROPOSED 10' WIDE ACCESS AND
UTILITY EASEMENT
EXISTING LANDSCAPING
(ANY DISTURBED OR REMOVED LANDSCAPING
WILL BE RELOCATED AND REPLACED
ELSEWHERE ON THE PROPERTY)
AND CONTACT OWNERS REPRESENTATIVE.
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
1
Z-2
ENLARGED SITE PLAN
SCALE: 3/32"=1'-0"
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
3/32 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
0 2 4 8 12 16 20
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
2
ENLARGED
SITE PLAN
Z-2
4
2
Z-3
N
PROPOSED 2'x3' FIBER VAULT
PROPOSED FIBER RUN FROM FIBER
VAULT TO EQUIPMENT SITE
PROPOSED 10' WIDE ACCESS
AND UTILITY EASEMENT
PROPOSED 10'x10' LEASE AREA
PROPOSED POWER RUN FORM
EXISTING 150 KVA TRANSFORMER
TO PROPOSED EQUIPMENT AREA
PROPOSED 2" CONDUIT WITH 3-CELL PLENUM
MAXCELL INNERDUCT TO MEET POINT IN R.O.W.
REMOVE EXISTING LIGHT POLE AND INSTALL
NEW ALL-IN-ONE SMALL CELL POLE
(PAINTED AND TEXTURED TO MATCH
EXISTING LIGHT POLES)
PROPOSED 10' WIDE ACCESS EASEMENT
PROPOSED CONCEALED
QUASI OMNI ANTENNA
EXISTING UNDERGROUND
ELECTRIC
EXISTING 150 KVA
TRANSFORMER TO BE UTILIZED
FOR POWER RUN
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
SITE PLAN
Z-1
3
McCLELLAND DR
APN:9726414040
PROPOSED 2'x3' FIBER
VAULT
EXISTING
LANDSCAPING
(37'-2")
EXISTING
BUILDING
(16')
EXISTING
BUILDING
(15')
EXISTING
BUILDING
(17')
EXISTING
BUILDING
(18'-4")
EXISTING
PARKING
LOT
PROPOSED FIBER RUN
FROM FIBER VAULT TO
EQUIPMENT SITE
EXISTING
LANDSCAPING
(35'-10")
EXISTING
LANDSCAPING
(31'-10")
PROPOSED 10' WIDE ACCESS
AND UTILITY EASEMENT
PROPOSED 10'x10'
LEASE AREA
REMOVE EXISTING LIGHT POLE AND
INSTALL NEW ALL-IN-ONE SMALL CELL POLE
EXISTING
LANDSCAPING
(35'-8")
EXISTING CURB
EXISTING PROPERTY LINE
EXISTING
LANDSCAPING
(35'-8")
LEGEND
W
SS
F
GAS GAS
OE
UT
X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD
E
UE
OT
EV
D
O
U/G
OHW
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
PROPOSED 10' WIDE ACCESS EASEMENT
EXISTING 150 KVA
TRANSFORMER TO BE
UTILIZED FOR POWER RUN
NOTE:
NO WIRELESS TELECOMMUNICATION FACILITY OR
EQUIPMENT OWNER OR LESSEE OR EMPLOYEE
THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO
EXCLUDE ANY OTHER WIRELESS
TELECOMMUNICATION PROVIDER FROM USING THIS
BUILDING, STRUCTURE OR LOCATION.
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 ENLARGED SITE PLAN
Z-3 EQUIPMENT PLAN
PROJECT DESCRIPTION
1. REMOVE EXISTING LIGHT POLE AND INSTALL NEW ALL-IN-ONE SMALL CELL POLE WITH
LIGHT TO MATCH EXISTING.
2. INSTALL (2) NEW REMOTE RADIO HEADS WITHIN NEW POLE.
3. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN.
4. RUN FIBER TO PROPOSED EQUIPMENT.
5. INSTALL ASSOCIATED SERVICE EQUIPMENT WITHIN NEW POLE.
6. NEW COMMERCIAL POWER TO SITE.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
JURISDICTION: CITY OF FT. COLLINS
ZONING: GC-GENERAL COMMERCIAL
APN: 9726414040
PARCEL SIZE: 19,204 S.F.
ELEVATION: 5038' (NAVD 88)
STRUCTURE TYPE: ALL-IN-ONE SMALL CELL POLE
STRUCTURE HEIGHT: 35'-0"±
ANTENNA RAD CENTER: 33'-3" AGL
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 662211
PH: 913-344-2030
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: 720 279-8973
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
F 09-21-17 RPH REVISED
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
G 11-09-17 LCW REVISED
Z-4 ELEVATIONS
LEGAL DESCRIPTION
SITUATED IN THE COUNTY OF LARIMER AND IN THE STATE OF COLORADO:
A PART OF LOT 23, SOUTH MESA SUBDIVISION, IN THE CITY OF FORT COLLINS, WHICH BEGINS AT
THE SOUTHWEST CORNER OF SAID LOT 23, AND RUN THENCE N 00°54' E 103.01 FEET TO THE
NORTHWEST CORNER LOT 23; THENCE N 89°55' E 189.23 FEET ALONG THE NORTH LINE OF SAID
LOT 23; THENCE S 00°05' E 103.00 FEET TO A POINT ON THE SOUTH LINE OF SAID LOT 23; THENCE S
89°55'W 191.00 FEET TO THE POINT OF BEGINNING.
PH-1 PHOTOSIMULATION VIEWS
PM-1 PHOTOMETRIC PLAN - EXISTING CONDITIONS
PM-2 PHOTOMETRIC PLAN - PROPOSED
LD-1 LINE DRAWING
Z-5 LANDSCAPING PLAN