Loading...
HomeMy WebLinkAboutFTC CHIPPERS SC WTE VERIZON PDP - PDP170027 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC CHIPPERS SC 3517 S MASON ST FT. COLLINS, COLORADO 80525 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: HEAD SOUTH TOWARD S VAUGHN WAY. TURN RIGHT ONTO S VAUGHN WAY. TURN LEFT TO MERGE ONTO CO-83 N TOWARD INTERSTATE 225. MERGE ONTO CO-83 N. USE THE RIGHT 3 LANES TO TAKE THE INTERSTATE 225 S EXIT. MERGE ONTO I-225 S. USE THE RIGHT 2 LANES TO TAKE EXIT 1B FOR INTERSTATE 25 N TOWARD FT. COLLINS. KEEP RIGHT AND MERGE ONTO I-25 N. CONTINUE ON I-25 N TOWARDS FORT COLLINS. TAKE EXIT 265 FOR HARMONY RD. TURN LEFT ONTO E HARMONY RD. CONTINUE ON HARMONY TO ZIEGLER RD. TURN RIGHT ON ZIEGLER RD. AT THE TRAFFIC CIRCLE TAKE THE 3RD EXIT ONTO E. HORSETOOTH RD. CONTINUE ON HORSETOOTH RD TO McCLELLAND DR. TURN RIGHT ON McCLELLAND DR. DESTINATION WILL BE ON THE RIGHT IN PARKING LOT FT. COLLINS, COLORADO CLIENT PROPERTY OWNER JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PHONE: 913-344-2030 BLACO INVESTMENTS LLC CONTACT: KATHRYN FOX PHONE: 970-227-3381 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT STREET, UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: Ram.Nandiraju@verizonwireless.com RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2012 (W/ LOCAL AMENDMENTS) NEC 2014 NFPA-1 (2006) U - UTILITY IIB REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED PHOTOSIMULATION VIEWS PH-1 2 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING EAST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST) N.T.S. ET UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T AC AC AC S S S EV ET X X X X X X X X F F F E E E UGE UGE UGE UGE UGE (E) 6' UTILITY EASEMENT (E) 10' DRAINAGE EASEMENT (E) 10' UTILITY EASEMENT 41'-2" T HIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 Z-1 SITE PLAN SCALE: 1"=30'-0" 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 15 0 7.5 15 30 60 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 05-12-17 BY UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T ET X F F F F F F F F F E E E E E E E E E E F UGE UGE UGE UGE UGE UGE UGE UGE U GE UGE UGE UGE UGE UGE UGE E E GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 8. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET EIA/TIA-222-G AS PER IBC 2012 REQUIREMENTS. 14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT UGE UGE UGE UGE UGE UGE F F F F F F F F F E E E E E E E E E E E UGE UGE UGE UGE UGE UGE UGE UGE UGE U GE UGE UGE UGE UGE UGE 10'-0" 10'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-3 PROPOSED EQUIPMENT DETAIL SCALE: 3/16"=1'-0" EQUIPMENT PLAN EXISTING CURB REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 35'-0" 30'-0" 35'-0" 33'-3" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 2 Z-4 PROPOSED ELEVATION - LOOKING EAST SCALE: 3/32"=1'-0" GRADE 0'-0" AGL 1 Z-4 EXISTING ELEVATION - LOOKING EAST SCALE: 3/32"=1'-0" 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 0 2 4 8 12 16 20 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 ELEVATIONS Z-4 6 TOP OF PROPOSED LIGHT 30'-0" AGL TOP OF EXISTING LIGHT POLE 35'-0" AGL GRADE 0'-0" AGL EXISTING LANDSCAPING EXISTING (TYP) BUILDING TOP OF PROPOSED POLE 35'-0" AGL REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T S S S EV ET X X X X X X X X UGE UGE UGE UGE UGE (E) 10' UTILITY EASEMENT U GE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T S S S EV ET X X X X X X X X UGE UGE UGE UGE UGE (E) 10' UTILITY EASEMENT T HIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N ET AC AC AC S S S EV ET X X X X X X X X 20'-0" PROPERTY LINE OFFSET THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 PM-1 PHOTOMETRIC PLAN - EXISTING SCALE: 1"=30'-0" 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 15 0 7.5 15 30 60 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED ET AC AC AC S S S EV ET X X X X X X X X 20'-0" PROPERTY LINE OFFSET THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 PM-1 PHOTOMETRRIC PLAN - PROPOSED SCALE: 1"=30'-0" 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 15 0 7.5 15 30 60 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED 4'-10" 32'-0" 2'-2" 2'-2" REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED LINE DRAWING LD-1 10 1 LD-1 METRO CELL LINE DRAWING N.T.S. ALL ASSOCIATED SERVICE EQUIPMENT WITHIN POLE BASE PROPOSED CONCEALED QUASI OMNI ANTENNA NOTE: POLE TO BE PAINTED AND TEXTURED TO MATCH EXISTING LIGHT POLES D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED PHOTOMETRIC PLAN - PROPOSED PM-2 9 McCLELLAND DR EXISTING LANDSCAPING (37'-2") EXISTING BUILDING (16') EXISTING BUILDING (15') EXISTING BUILDING (17') EXISTING BUILDING (18'-4") EXISTING LANDSCAPING (35'-10") EXISTING LANDSCAPING (31'-10") REMOVE EXISTING LIGHT POLE AND INSTALL NEW ALL-IN-ONE SMALL CELL POLE (PAINTED AND TEXTURED TO MATCH EXISTING LIGHT POLES) EXISTING LANDSCAPING (35'-8") EXISTING CURB EXISTING PROPERTY LINE EXISTING LANDSCAPING (35'-8") D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED PHOTOMETRIC PLAN - EXISTING CONDITIONS PM-1 8 McCLELLAND DR EXISTING LANDSCAPING (37'-2") EXISTING BUILDING (16') EXISTING BUILDING (15') EXISTING BUILDING (17') EXISTING BUILDING (18'-4") EXISTING LANDSCAPING (35'-10") EXISTING LANDSCAPING (31'-10") EXISTING LANDSCAPING (35'-8") EXISTING CURB EXISTING PROPERTY LINE EXISTING LANDSCAPING (35'-8") 1 Z-5 LANDSCAPING PLAN - EXISTING SCALE: 1"=30'-0" 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 15 0 7.5 15 30 60 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED LANDSCAPING PLAN Z-5 7 McCLELLAND DR EXISTING LANDSCAPING (37'-2") EXISTING PARKING LOT EXISTING LANDSCAPING (35'-10") EXISTING LANDSCAPING (31'-10") EXISTING LANDSCAPING (35'-8") EXISTING CURB EXISTING PROPERTY LINE EXISTING LANDSCAPING (35'-8") McCLELLAND DR EXISTING LANDSCAPING (37'-2") EXISTING PARKING LOT EXISTING LANDSCAPING (35'-10") EXISTING LANDSCAPING (31'-10") EXISTING LANDSCAPING (35'-8") EXISTING CURB EXISTING PROPERTY LINE EXISTING LANDSCAPING (35'-8") EXISTING LIGHTPOLE (TO BE REMOVED) REMOVE EXISTING LIGHT POLE AND REPLACE WITH NEW ALL-IN-ONE SMALL CELL POLE (PAINTED AND TEXTURED TO MATCH EXISTING LIGHT POLES) EXISTING LANDSCAPING (ANY DISTURBED OR REMOVED LANDSCAPING WILL BE RELOCATED AND REPLACED ELSEWHERE ON THE PROPERTY) EXISTING LANDSCAPING SHRUBS WITHIN ISLAND (TYP) 2 Z-5 LANDSCAPING PLAN - PROPOSED SCALE: 1"=30'-0" 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 15 0 7.5 15 30 60 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED EXISTING BUILDING EXISTING LANDSCAPING (TYP) REMOVE EXISTING LIGHT POLE AND REPLACE WITH NEW ALL-IN-ONE SMALL CELL POLE (PAINTED AND TEXTURED TO MATCH EXISTING LIGHT POLES) PROPOSED CONCEALED QUASI OMNI ANTENNA PROPOSED VERIZON RAD CENTER 33'-3" AGL PROPOSED SLENDERFORM 48 LED, 240V LIGHTING EXISTING LIGHT POLE (TO BE REMOVED AND REPLACED) EXISTING LANDSCAPING (ANY DISTURBED OR REMOVED LANDSCAPING WILL BE RELOCATED AND REPLACED ELSEWHERE ON THE PROPERTY) FAX: (720) 304-6883 G 11-09-17 LCW REVISED 0 1 2 4 8 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 3/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 5 Z-3 PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED POWER RUN FROM EXISTING 150KVA TRANSFORMER TO EQUIPMENT SITE EXISTING UNDERGROUND ELECTRIC PROPOSED 10'x10' LEASE AREA REMOVE EXISTING LIGHT POLE AND INSTALL NEW ALL-IN-ONE SMALL CELL POLE (PAINTED AND TEXTURED TO MATCH EXISTING LIGHT POLES) PROPOSED CONCEALED QUASI OMNI ANTENNA PROPOSED 10' WIDE ACCESS AND UTILITY EASEMENT EXISTING LANDSCAPING (ANY DISTURBED OR REMOVED LANDSCAPING WILL BE RELOCATED AND REPLACED ELSEWHERE ON THE PROPERTY) AND CONTACT OWNERS REPRESENTATIVE. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-2 ENLARGED SITE PLAN SCALE: 3/32"=1'-0" REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 0 2 4 8 12 16 20 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 ENLARGED SITE PLAN Z-2 4 2 Z-3 N PROPOSED 2'x3' FIBER VAULT PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED 10' WIDE ACCESS AND UTILITY EASEMENT PROPOSED 10'x10' LEASE AREA PROPOSED POWER RUN FORM EXISTING 150 KVA TRANSFORMER TO PROPOSED EQUIPMENT AREA PROPOSED 2" CONDUIT WITH 3-CELL PLENUM MAXCELL INNERDUCT TO MEET POINT IN R.O.W. REMOVE EXISTING LIGHT POLE AND INSTALL NEW ALL-IN-ONE SMALL CELL POLE (PAINTED AND TEXTURED TO MATCH EXISTING LIGHT POLES) PROPOSED 10' WIDE ACCESS EASEMENT PROPOSED CONCEALED QUASI OMNI ANTENNA EXISTING UNDERGROUND ELECTRIC EXISTING 150 KVA TRANSFORMER TO BE UTILIZED FOR POWER RUN KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED SITE PLAN Z-1 3 McCLELLAND DR APN:9726414040 PROPOSED 2'x3' FIBER VAULT EXISTING LANDSCAPING (37'-2") EXISTING BUILDING (16') EXISTING BUILDING (15') EXISTING BUILDING (17') EXISTING BUILDING (18'-4") EXISTING PARKING LOT PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE EXISTING LANDSCAPING (35'-10") EXISTING LANDSCAPING (31'-10") PROPOSED 10' WIDE ACCESS AND UTILITY EASEMENT PROPOSED 10'x10' LEASE AREA REMOVE EXISTING LIGHT POLE AND INSTALL NEW ALL-IN-ONE SMALL CELL POLE EXISTING LANDSCAPING (35'-8") EXISTING CURB EXISTING PROPERTY LINE EXISTING LANDSCAPING (35'-8") LEGEND W SS F GAS GAS OE UT X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD E UE OT EV D O U/G OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING PROPOSED 10' WIDE ACCESS EASEMENT EXISTING 150 KVA TRANSFORMER TO BE UTILIZED FOR POWER RUN NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 ENLARGED SITE PLAN Z-3 EQUIPMENT PLAN PROJECT DESCRIPTION 1. REMOVE EXISTING LIGHT POLE AND INSTALL NEW ALL-IN-ONE SMALL CELL POLE WITH LIGHT TO MATCH EXISTING. 2. INSTALL (2) NEW REMOTE RADIO HEADS WITHIN NEW POLE. 3. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN. 4. RUN FIBER TO PROPOSED EQUIPMENT. 5. INSTALL ASSOCIATED SERVICE EQUIPMENT WITHIN NEW POLE. 6. NEW COMMERCIAL POWER TO SITE. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: GC-GENERAL COMMERCIAL APN: 9726414040 PARCEL SIZE: 19,204 S.F. ELEVATION: 5038' (NAVD 88) STRUCTURE TYPE: ALL-IN-ONE SMALL CELL POLE STRUCTURE HEIGHT: 35'-0"± ANTENNA RAD CENTER: 33'-3" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 662211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED F 09-21-17 RPH REVISED 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 G 11-09-17 LCW REVISED Z-4 ELEVATIONS LEGAL DESCRIPTION SITUATED IN THE COUNTY OF LARIMER AND IN THE STATE OF COLORADO: A PART OF LOT 23, SOUTH MESA SUBDIVISION, IN THE CITY OF FORT COLLINS, WHICH BEGINS AT THE SOUTHWEST CORNER OF SAID LOT 23, AND RUN THENCE N 00°54' E 103.01 FEET TO THE NORTHWEST CORNER LOT 23; THENCE N 89°55' E 189.23 FEET ALONG THE NORTH LINE OF SAID LOT 23; THENCE S 00°05' E 103.00 FEET TO A POINT ON THE SOUTH LINE OF SAID LOT 23; THENCE S 89°55'W 191.00 FEET TO THE POINT OF BEGINNING. PH-1 PHOTOSIMULATION VIEWS PM-1 PHOTOMETRIC PLAN - EXISTING CONDITIONS PM-2 PHOTOMETRIC PLAN - PROPOSED LD-1 LINE DRAWING Z-5 LANDSCAPING PLAN