HomeMy WebLinkAboutFTC CHIPPERS SC WTE VERIZON PDP - PDP170027 - DOCUMENT MARKUPS - ROUND 1 -FTC CHIPPERS SC
3517 S MASON ST
FT. COLLINS, COLORADO 80525
SMALL CELL
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
DEPART 3131 S VAUGHN WAY, AURORA, CO 80014:
HEAD SOUTH TOWARD S VAUGHN WAY. TURN RIGHT ONTO S VAUGHN WAY. TURN LEFT TO MERGE
ONTO CO-83 N TOWARD INTERSTATE 225. MERGE ONTO CO-83 N. USE THE RIGHT 3 LANES TO
TAKE THE INTERSTATE 225 S EXIT. MERGE ONTO I-225 S. USE THE RIGHT 2 LANES TO TAKE EXIT 1B
FOR INTERSTATE 25 N TOWARD FT. COLLINS. KEEP RIGHT AND MERGE ONTO I-25 N. CONTINUE ON
I-25 N TOWARDS FORT COLLINS. TAKE EXIT 265 FOR HARMONY RD. TURN LEFT ONTO E HARMONY
RD. CONTINUE ON HARMONY TO ZIEGLER RD. TURN RIGHT ON ZIEGLER RD. AT THE TRAFFIC
CIRCLE TAKE THE 3RD EXIT ONTO E. HORSETOOTH RD. CONTINUE ON HORSETOOTH RD TO
McCLELLAND DR. TURN RIGHT ON McCLELLAND DR. DESTINATION WILL BE ON THE RIGHT IN
PARKING LOT
FT. COLLINS, COLORADO
CLIENT
PROPERTY OWNER
JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 66211
PHONE: 913-344-2030
BLACO INVESTMENTS LLC
CONTACT: KATHRYN FOX
PHONE: 970-227-3381
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JASON SHELLEDY
PHONE: 970-646-1283
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
1196 GRANT STREET, UNIT 313
DENVER, CO 80203
CONTACT: RYAN SAGAR
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: Ram.Nandiraju@verizonwireless.com
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2012 (W/ LOCAL AMENDMENTS)
NEC 2014
NFPA-1 (2006)
U - UTILITY
IIB
ET
AC
AC
AC
S
S
S
EV
ET
(E) 6' UTILITY EASEMENT
(E) 10' DRAINAGE EASEMENT
(E) 10' UTILITY EASEMENT
T
HIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
1
Z-1
SITE PLAN
SCALE: 1"=30'-0"
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
STEVEN MARK MUSTARO JR, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #52559 (EXP. 10/31/2017)
OF 5
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 06-06-17 KRC REVISED
35'-5"
32'-5"
35'-5"
8'-0"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
2
Z-4
PROPOSED SOUTH ELEVATION
SCALE: 3/32"=1'-0"
GRADE
0'-0" AGL
1
Z-4
EXISTING SOUTH ELEVATION
SCALE: 3/32"=1'-0"
ELEVATIONS
Z-4
5
PROPOSED VERIZON RAD CENTER
32'-5" AGL
TOP OF EXISTING LIGHT POLE
35'-5" AGL
GRADE
0'-0" AGL
PROPOSED AWS & PCS RRH
INSIDE 60W SHROUD
PROPOSED 60W
SHROUD
PROPOSED VERIZON ANTENNA
MOUNTED ON EXISTING POLE
PROPOSED H-FRAME WITH
METER AND DISCONNECT EXISTING
LANDSCAPING
(TYP)
EXISTING
BUILDING
TOP OF EXISTING LIGHT POLE
35'-5" AGL
PROPOSED 8' TALL
CEDAR FENCE
PROPOSED COAX ROUTED
OUTSIDE POLE
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
STEVEN MARK MUSTARO JR, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #52559 (EXP. 10/31/2017)
OF 5
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
Line Over Text
8/16/17
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
SITE PLAN
Z-1
2
APN:9726414040
PROPOSED 2'x3' FIBER
VAULT
EXISTING
LANDSCAPING
(37'-2")
EXISTING
BUILDING
(16')
EXISTING
BUILDING
(15')
EXISTING
BUILDING
(17')
EXISTING
BUILDING
(18'-4")
EXISTING
PARKING
LOT
PROPOSED FIBER RUN
FROM FIBER VAULT TO
EQUIPMENT SITE
EXISTING
LANDSCAPING
(35'-10")
EXISTING
LANDSCAPING
(31'-10")
PROPOSED 10' WIDE ACCESS
AND UTILITY EASEMENT
PROPOSED LEASE AREA
PROPOSED INSTALL OF ANTENNA
ON EXISTING 35' POLE
EXISTING
LANDSCAPING
(35'-8")
EXISTING CURB
EXISTING PROPERTY LINE
EXISTING
LANDSCAPING
(35'-8")
LEGEND
S
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
EV
D
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
PROPOSED 10' WIDE ACCESS EASEMENT
Rotate Text 180°.
Rotate Text 180°.
Line Over Text
8/16/17
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 EQUIPMENT PLAN & ANTENNA LAYOUT
Z-3 COMPOUND DETAILS
PROJECT DESCRIPTION
1. INSTALL NEW EQUIPMENT ON H-FRAME WITHIN LEASE AREA.
2. INSTALL (1) NEW ANTENNA ON EXISTING 35' POLE.
3. INSTALL (2) NEW REMOTE RADIO HEADS ON H-FRAME.
4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN.
5. RUN FIBER TO PROPOSED EQUIPMENT.
6. INSTALL ASSOCIATED SERVICE EQUIPMENT ON H-FRAME.
7. NEW COMMERCIAL POWER TO SITE.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
JURISDICTION: CITY OF FT. COLLINS
ZONING: GC-GENERAL COMMERCIAL
APN: 9726414040
PARCEL SIZE: 19,204 S.F.
ELEVATION: 5038' (NAVD 88)
STRUCTURE TYPE: ANTENNA TO EXISTING POLE
STRUCTURE HEIGHT: 35'-0"±
ANTENNA RAD CENTER: 32'-5" AGL
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 662211
PH: 913-344-2030
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: 720 279-8973
REVISION SCHEDULE
REV
A
DATE
05-12-17
BY
KRC PRELIMINARY
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
STEVEN MARK MUSTARO JR, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #52559 (EXP. 10/31/2017)
OF 5
SITE NAME:
FTC CHIPPERS SC
SITE ADDRESS:
3517 S MASON ST
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0101
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
B 06-06-17 KRC REVISED
C 06-08-17 KRC REVISED
D 07-05-17 GAC REVISED
E 07-10-17 KRC REVISED
Z-4 ELEVATIONS
Does not match the titles
on these sheets.
8/16/17
Plans must be 24"x36".
Add a legal description for the
property where this is located.