Loading...
HomeMy WebLinkAboutFTC CHIPPERS SC WTE VERIZON PDP - PDP170027 - DOCUMENT MARKUPS - ROUND 1 - CITY STAFFFTC CHIPPERS SC 3517 S MASON ST FT. COLLINS, COLORADO 80525 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: HEAD SOUTH TOWARD S VAUGHN WAY. TURN RIGHT ONTO S VAUGHN WAY. TURN LEFT TO MERGE ONTO CO-83 N TOWARD INTERSTATE 225. MERGE ONTO CO-83 N. USE THE RIGHT 3 LANES TO TAKE THE INTERSTATE 225 S EXIT. MERGE ONTO I-225 S. USE THE RIGHT 2 LANES TO TAKE EXIT 1B FOR INTERSTATE 25 N TOWARD FT. COLLINS. KEEP RIGHT AND MERGE ONTO I-25 N. CONTINUE ON I-25 N TOWARDS FORT COLLINS. TAKE EXIT 265 FOR HARMONY RD. TURN LEFT ONTO E HARMONY RD. CONTINUE ON HARMONY TO ZIEGLER RD. TURN RIGHT ON ZIEGLER RD. AT THE TRAFFIC CIRCLE TAKE THE 3RD EXIT ONTO E. HORSETOOTH RD. CONTINUE ON HORSETOOTH RD TO McCLELLAND DR. TURN RIGHT ON McCLELLAND DR. DESTINATION WILL BE ON THE RIGHT IN PARKING LOT FT. COLLINS, COLORADO CLIENT PROPERTY OWNER JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PHONE: 913-344-2030 BLACO INVESTMENTS LLC CONTACT: KATHRYN FOX PHONE: 970-227-3381 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT STREET, UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: Ram.Nandiraju@verizonwireless.com RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2012 (W/ LOCAL AMENDMENTS) NEC 2014 NFPA-1 (2006) U - UTILITY IIB ET AC AC AC S S S EV ET (E) 6' UTILITY EASEMENT (E) 10' DRAINAGE EASEMENT (E) 10' UTILITY EASEMENT T HIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 Z-1 SITE PLAN SCALE: 1"=30'-0" REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: STEVEN MARK MUSTARO JR, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52559 (EXP. 10/31/2017) OF 5 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 06-06-17 KRC REVISED ET GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 8. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET EIA/TIA-222-G AS PER IBC 2012 REQUIREMENTS. 14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-2 EQUIPMENT PLAN SCALE: 3/32"=1'-0" A SECTOR CABLE TABLE N/A AZIMUTH TBD LENGTH 2 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. Know what's below. Call before you dig. 1 Z-4 PROPOSED COMPOUND DETAIL SCALE: 3/16"=1'-0" REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: STEVEN MARK MUSTARO JR, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52559 (EXP. 10/31/2017) OF 5 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED 4 Z-3 35'-5" 32'-5" 35'-5" 8'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 2 Z-4 PROPOSED SOUTH ELEVATION SCALE: 3/32"=1'-0" GRADE 0'-0" AGL 1 Z-4 EXISTING SOUTH ELEVATION SCALE: 3/32"=1'-0" ELEVATIONS Z-4 5 PROPOSED VERIZON RAD CENTER 32'-5" AGL TOP OF EXISTING LIGHT POLE 35'-5" AGL GRADE 0'-0" AGL PROPOSED AWS & PCS RRH INSIDE 60W SHROUD PROPOSED 60W SHROUD PROPOSED VERIZON ANTENNA MOUNTED ON EXISTING POLE PROPOSED H-FRAME WITH METER AND DISCONNECT EXISTING LANDSCAPING (TYP) EXISTING BUILDING TOP OF EXISTING LIGHT POLE 35'-5" AGL PROPOSED 8' TALL CEDAR FENCE PROPOSED COAX ROUTED OUTSIDE POLE REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: STEVEN MARK MUSTARO JR, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52559 (EXP. 10/31/2017) OF 5 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 1/2" COAX REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: STEVEN MARK MUSTARO JR, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52559 (EXP. 10/31/2017) OF 5 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED EQUIPMENT PLAN Z-2 3 2 Z-3 N PROPOSED 2'x3' FIBER VAULT PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED 10' WIDE ACCESS AND UTILITY EASEMENT PROPOSED LEASE AREA PROPOSED H-FRAME WITH METER AND DISCONNECT PROPOSED POWER PROPOSED 8' TALL CEDAR FENCE OFFSET 6" FROM EDGE OF LEASE AREA PROPOSED 2' WIDE ICE BRIDGE PROPOSED 2" CONDUIT WITH 3-CELL PLENUM MAXCELL INNERDUCT TO MEET POINT IN R.O.W. PROPOSED VERIZON ANTENNA MOUNTED ON EXISTING 35' POLE PROPOSED SMALL CELL CABINET MOUNTED TO H-FRAME PROPOSED PCS RRH MOUNTED TO H-FRAME PROPOSED AWS RRH MOUNTED TO H-FRAME PROPOSED 10' WIDE ACCESS EASEMENT C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED SITE PLAN Z-1 2 APN:9726414040 PROPOSED 2'x3' FIBER VAULT EXISTING LANDSCAPING (37'-2") EXISTING BUILDING (16') EXISTING BUILDING (15') EXISTING BUILDING (17') EXISTING BUILDING (18'-4") EXISTING PARKING LOT PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE EXISTING LANDSCAPING (35'-10") EXISTING LANDSCAPING (31'-10") PROPOSED 10' WIDE ACCESS AND UTILITY EASEMENT PROPOSED LEASE AREA PROPOSED INSTALL OF ANTENNA ON EXISTING 35' POLE EXISTING LANDSCAPING (35'-8") EXISTING CURB EXISTING PROPERTY LINE EXISTING LANDSCAPING (35'-8") LEGEND S T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX EV D STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING PROPOSED 10' WIDE ACCESS EASEMENT BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 EQUIPMENT PLAN & ANTENNA LAYOUT Z-3 COMPOUND DETAILS PROJECT DESCRIPTION 1. INSTALL NEW EQUIPMENT ON H-FRAME WITHIN LEASE AREA. 2. INSTALL (1) NEW ANTENNA ON EXISTING 35' POLE. 3. INSTALL (2) NEW REMOTE RADIO HEADS ON H-FRAME. 4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN. 5. RUN FIBER TO PROPOSED EQUIPMENT. 6. INSTALL ASSOCIATED SERVICE EQUIPMENT ON H-FRAME. 7. NEW COMMERCIAL POWER TO SITE. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: GC-GENERAL COMMERCIAL APN: 9726414040 PARCEL SIZE: 19,204 S.F. ELEVATION: 5038' (NAVD 88) STRUCTURE TYPE: ANTENNA TO EXISTING POLE STRUCTURE HEIGHT: 35'-0"± ANTENNA RAD CENTER: 32'-5" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 662211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV A DATE 05-12-17 BY KRC PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: STEVEN MARK MUSTARO JR, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52559 (EXP. 10/31/2017) OF 5 SITE NAME: FTC CHIPPERS SC SITE ADDRESS: 3517 S MASON ST FORT COLLINS, CO 80525 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0101 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 B 06-06-17 KRC REVISED C 06-08-17 KRC REVISED D 07-05-17 GAC REVISED E 07-10-17 KRC REVISED Z-4 ELEVATIONS