Loading...
HomeMy WebLinkAboutCHRISTIAN BROTHERS AUTOMOTIVE - FDP - FDP170034 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTPrepared For: CHRISTIAN BROTHERS AUTOMOTIVE CENTER 17725 KATY FREEWAY, SUITE 200 HOUSTON, TX 77094 BLOCK 1– UPLANDS PROSPECT BUSINESS PARK P.U.D. FORT COLLINS, CO FINAL DRAINAGE REPORT October 25, 2017 Job #co 15298 PROJECT SITE INDEX ITEM PAGE GENERAL LOCATION & DESCRIPTION......................................................................... 1 DRAINAGE BASINS & SUB-BASINS............................................................................... 2 DRAINAGE DESIGN CRITERIA...................................................................................... 2 DRAINAGE FACILITY DESIGN........................................................................................ 4 CONCLUSIONS.............................................................................................................. 6 REFERENCES................................................................................................................. 6 ATTACHMENTS Appendix A: Vicinity Map Appendix B: Hydrologic Computations Historic and Developed  Weighted C Factor  Time of Concentration  Peak Runoff  Design Tables Appendix C: Hydraulic Computations Appendix D: NRCS Soils Map Appendix E: Proposed Drainage Plan Page | 1 I. GENERAL LOCATION AND DESCRIPTION A. Location 1. A vicinity map has been provided in Appendix A. 2. The project is located in Block 1, Uplands Prospect Business Park P.U.D. in the East ½ of Section 18, Township 7 North, Range 68 West of the 6th Prime Meridian, City of Fort Collins, County of Larimer, State of Colorado. 3. The project site is located at the northeast corner of the intersection of East Prospect Road and Academy Court. 4. There are no major drainage ways, facilities or drainage easements within or adjacent to the site. 5. To the northeast, the property is bound by the Great Western Railway, to the south by East Prospect Road and to the west, Academy Court. Life Church of Fort Collins and Front Range Community College are located on the west side of Academy Court, The Coterie Natural Area lies south of East Prospect Road, and Bath Garden Center and Nursery lies to the east of the site. B. Description of Property 1. The total area of the Lot is 1.147 acres. The project will disturb approximately 0.790 acres of the western lot area. The remaining 0.357 acres is covered by a 35- foot wide Platte River Power Authority easement and an overall 40.5-foot wide Utility Easement, minimal disturbance will occur in the easement. 2. The eastern 40.5 feet of the property is an occupied utility easement, City of Fort Collins storm and sanitary mains have been installed, and along the eastern edge is a Platte River Power Authority transmission line. The remainder of the property is undeveloped and is covered primarily with native grass and vegetation. The site was over-lot graded at the time of development of the subdivision. The majority of the site has a slight 1 to 3 percent slope to the northeast; the eastern edge has a slope of 3 to 5 percent to the east. The NRCS Soil Report classifies the soil as well drained. A copy of the report is provided in Appendix D. 3. No major drainage ways directly impact the site. The Cache La Poudre River lies to the north and Spring Creek lies to the south. 4. The project will include the construction of the service facility, parking, associated utility installation & landscaping. On-site detention is provided on the east side of the service facility. 5. There are no irrigation facilities on or near the project site. 6. Proposed land use is for a light automotive repair and service facility. The site is zoned Industrial District (I) which allows this use. Page | 2 C. Floodplain Submittal Requirements 1. The site is not in a floodplain. 2. The FEMA FIRM panel number 08069C0983H, revised May 2, 2012, was referenced and a copy is included in Appendix E. II. DRAINAGE BASINS AND SUB-BASINS A. Major Basin Description 1. This project is in the Spring Creek Drainage Basin. 2. The area of the Spring Creek Drainage Basin, the project is located in is mostly developed. The project site is a single lot infill development. 3. No irrigation facilities are known to influence or be influenced by the local drainage design of this project. B. Sub-Basin Description 1. Historic drainage patterns for the property are typically from west to east and northeast. The subdivision currently has internal streets and utility infrastructure installed. 2. This Lot is protected from offsite flows, on the west and south sides by the existing curb & gutters of Academy Court and E Prospect Road respectively. This site slopes away from the existing streets and has no offsite flow impacts. III. DRAINAGE DESIGN CRITERIA A. Regulations 1. There are no deviations from the criteria. The site was designed to accommodate the allowable parking numbers, and emergency vehicle easements with the most efficient layout. Runoff from impervious surfaces is conveyed to a rain garden above the detention pond or overland on landscape surfaces to the on-site detention pond. The detention pond was designed with Water Quality Capture Volume (WQCV) in addition to the 100-year storm developed runoff volume. The outlet structure is designed to slowly release flows from frequent storm events and release flows up to a 100-year storm event at no more than the 2-year historic runoff rate. 2. The project site has an existing storm sewer with catch basins installed in the utility easement along the east boundary. The site’s detained flows will be released into this existing storm sewer. By releasing site flows up to a 100-year storm event at the 2-year historic rate into the existing storm sewer, flows to the existing catch basins will be reduced over current condition events which exceed a 2-year event. Page | 3 B. Directly Connected Impervious Area (DCIA) and Four Step Process Compliance 1. Employ Runoff Reduction Practices: This site uses a rain garden to treat sediment and convey site runoff from the building, drive isle and parking areas to the detention pond. 2. Implement BMPs that provide a WQCV with slow release: This site uses a rain garden in addition to a WQCV. The release rate of the WQCV is 40 hours. 3. Stabilize Drainage ways: This site will release developed flows at a 2-yr historic rate into an existing storm sewer system on the project site. 4. Implement Site Specific and Other Source Control BMPs: A separate Erosion and Sediment Control Plan has been developed with source control BMPs used from ground breaking operations to permanent stabilization installations. C. Development Criteria Reference and Constraints 1. No adjacent drainage studies were available at the time this report was written. All developed lots in the subject subdivision have on-site detention ponds. This project site is protected from off-site runoff by existing curb and gutter on the upslope sides. Developed flow from this site will be detained on-site and released directly into the existing storm sewer at the 2-year historic rate. 2. There are no known adjacent drainage studies. The Uplands Prospect Business Park is bound on the east and west sides by existing railroad tracts. There are no effects from adjacent drainage studies. 3. This Project Site is an infill development in an existing subdivision. Development of this site will not cause any drainage impact any existing infrastructure. D. Hydrological Criteria 1. Rainfall data was obtained from the City of Fort Collins Storm Drainage Design Criteria Manual, Table RA-8. Rainfall data used for this design is as follows: 2 year 0.82 in. 10 year 1.40 in. 100 year 2.86 in. 2. The Rational Method was used to calculate runoff. Per the Fort Collins Storm water Criteria, the runoff coefficients were adjusted for infrequent storms. Therefore the C100 was applied a frequency factor of Cf=1.25. Storm Return Period Frequency Factor, Cf 2 to 10 1.00 11 to 25 1.10 26 to 50 1.20 51 to 100 1.25 Page | 4 3. Detention pond sizing, outlet structure configuration, and discharge rates were calculated using the City of Fort Collins, Rational Method Spreadsheet Template. The detention storage was sized for WQCV plus the 100-year developed flows, the release rate is the 2-year historic flow. The stage storage volume of the pond was calculated using the UDFCD spreadsheet UD-Detention. Calculations in this study are based on the disturbed area of 0.735 acres per discussions with City of Fort Collins staff. 4. For the purposes of this design, the 2-year storm will be considered the Minor storm, and the 100-year storm will be considered the Major storm. 5. No other calculation methods were used for this report. E. Hydraulic Criteria 1. Per the Fort Collins Storm Water Criteria, detention volume is calculated using the Rational FAA method and per criteria, increased by 20% to account for the larger resulting storage volume that would be obtained from SWMM modeling. Per discussions with City of Fort Collins staff, the volume increase is not required. This site is also less than 5 acres. 2. No additional drainage facility design criteria were used. 3. No modifications to any 100-year floodplain or floodway are proposed as part of this project. 4. No modifications to any natural drainage ways are proposed as part of this project. F. Floodplain Regulations Compliance 1. The site is not in a floodplain or floodway. G. Modifications of Criteria 1. There is no modification of criteria requested. H. Modifications of Criteria 2. There is no modification of criteria requested. IV. DRAINAGE FACILITY DESIGN A. General Concept 1. Typical drainage patterns for this Lot are generally to the east and northeast, toward the existing Great Western Railway tracks. Developed flows will be a combination of sheet flow, concentrated gutter flow and grass swale. The time of concentration for the project was calculated to the detention pond outlet. 2. There are no off-site flows to consider on this project site. Page | 5 3. Input and Output results of the Historic Condition and Developed Condition Fort Collins Rational Method Spreadsheet analysis are in Appendix B. Input and Output results of the Detention Volume (Mass Balance), WQCV and Stage Storage Table are in Appendix C. 4. The proposed drainage pattern will generally follow existing drainage patterns of west to east. B. Specific Details 1. This site has a triangular shape with the low point being at the narrow end of the lot and a wide utility easement on the east side of the lot. Detention area was obtained by moving the building west on the lot to minimize impervious areas and using the open space between the back of the building and utility easement. Of the 0.79 acres impacted by this project, 0.67 acres of the project will drain to the rain garden and or detention pond. Areas of landscaping adjacent to Academy Court and Prospect Road will follow historic drainage patterns in existing swales to on-site catch basins or towards the street. These undetained flows will remain at historic rates. The LID requirements are met by designing a rain garden above the detention pond, to provide water quality benefits prior to entering the detention area. The rain garden is sized to treat the impervious area of the parking and drive aisles and the west half of the building. The east half of the building will drain across grass slopes into the detention pond which will provide additional water quality control for frequent, low intensity storms. The total impervious area of the project is 19,012 S.F. A minimum of 75% or 14,259 S.F. of the impervious area is required to flow to the rain garden. The project will direct 16,354 S.F. of impervious area runoff, or 86% of runoff from impervious areas to the rain garden. The rain garden is sized based on 16,354 S.F. of impervious area from the west half of the building and the parking and paved areas. The required flat area is 326 S.F., the provided flat area is 465 S.F. The required volume is 543 C.F., the provided volume is 683 C.F. The depth of the rain garden is 12-inches. Calculations for the rain garden are included in Appendix C. 2. Detention storage & outlet design: The calculated 100-yr detention volume plus Water Quality Capture Volume (WQCV) is 0.222 acre-ft using the City of Fort Collins Rational Method spreadsheet. The outlet will consist of a single stage structure, to pond the WQCV, then release excess runoff at the 2-year historic runoff rate up to the 100-yr plus WQCV elevation. WQCV of 0.025 acre-feet is provided in addition to the rain garden volume benefits. 3. An overflow weir is designed to release flows that exceed the 100-yr storm event runoff volume. The emergency flows will be directed towards existing inlets installed on the storm sewer on the site. 4. Summary table: The required information can be found in Appendix C of this report. Page | 6 5. Maintenance access: The maintenance access will be from the east side of the pond. 6. Easements: No easements are impacted as part of this project. 7. Offsite facilities: No new offsite facilities are required as part of this project. V. CONCLUSIONS A. Compliance with standards 1. This report and drainage design is in compliance with all known criteria published by the City of Fort Collins. 2. This drainage plan complies with the Spring Creek Master Plan based on criteria conveyed from the City of Fort Collins. 3. Compliance w/ City floodplain regulations. This site is not in a floodplain and no floodplains are impacted as part of this project. 4. Compliance w/ State & Federal regulations. This project is in compliance with all known City, State and Federal regulations. B. Drainage Concept 1. The concepts put forth in this study will be effective in maintaining the historic flow rates for this site while providing adequate water quality treatment. 2. This drainage plan complies with the City of Fort Collins Storm water Criteria Manual and all know Master Drainage Plan recommendations. VI. REFERENCES 1. Stormwater Criteria Manual, City of Fort Collins, Colorado, as adopted December-2011 and February-2013. 2. Urban Storm Drainage Criteria Manual, Vol. 1, 2 and 3, Urban Drainage and Flood Control District, Denver, Colorado, June 2001. APPENDIX A VICINITY MAP APPENDIX B HYDROLOGIC COMPUTATIONS 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 0 10 20 30 40 50 60 70 80 90 100 110 120 Rainfall Intensity (inches/hour) Storm Duration (minutes) 100-Year Storm 10-Year Storm 2-Year Storm Rational Method Runoff Coefficients for Composite Analysis Table RO-11 of the Fort Collins Amendments to the UDFCD Criteria Manual Character or Surface Runoff Coefficient Streets, Parking Lots, Drives: Asphalt 0.95 Concrete 0.95 Gravel 0.5 Roofs 0.95 Recycled Asphalt 0.8 Lawns, Sandy Soil, Flat < 2% 0.1 Lawns, Sandy Soil, Avg 2-7% 0.15 Lawns, Sandy Soil, Steep >7% 0.2 Lawns, Heavy Soil, Flat < 2% 0.2 Lawns, Heavy Soil, Avg 2-7% 0.25 Steep >7% 0.35 Equation RO-8 of the Fort Collins Amendments to the UDFCD Criteria Manual C=Composite Runoff Coefficient Ci=Runoff Coefficient for Specific Area (Ai) Ai=Area of Surface with Runoff Coefficient of Ci, acres or square feet n=number of different surfaces to be considered At=Total Area over which C is applicable, acres or square feet Rational Method Runoff Coefficients for Composite Analysis - Adjustment for Infrequent Storms Table RO-12 of the Fort Collins Amendments to the UDFCD Criteria Manual Storm Return Period Frequency Factor, Cf 2 to 10 1.00 11 to 25 1.10 26 to 50 1.20 51 to 100 1.25 Example Calculation Table Basin or Sub-Basin Total Area (acres) Roof Area (acres) Paved Area (acres) Sidewalk Area (acres) Gravel Area (acres) Landscape Area (acres) Composite Runoff Coefficient, C (2 to 10-yr) Composite Runoff Coefficient, C (11 to 25-yr) Composite Runoff Coefficient, C (26 to 50-yr) Composite Runoff Coefficient, C ( 51 to 100-yr) Historic 0.79 0.00 0.00 0.00 0.00 0.79 0.25 0.28 0.30 0.31 Developed 0.79 0.12 0.31 0.00 0.00 0.36 0.63 0.70 0.76 0.79 Basin 1 0.37 0.06 0.31 0.01 0.94 1.00 1.00 1.00 Basin 2 0.30 0.06 0.24 0.39 0.43 0.47 0.49 Basin Information Surface Type Runoff Coefficients Example Calculation Table Basin or Sub-Basin Total Area (acres) C (2-yr) C (100-yr) Length (ft) Slope (%) Ti (2-yr) Ti (100-yr) Length (ft) Slope (%) Ground Cover Velocity (ft/sec) (manual input) Tt Total Tc (2-yr) Total Tc (100-yr) Tc Maximum** for Urbanized Basins = (Length/180)+10 Final Tc (2-yr)* Final Tc (100-yr) * Historic 0.79 0.25 0.31 86.00 2.29 11.19 9.34 190 2.38 PL 1.1 2.88 14.07 12.21 11.53 11.53 11.53 Developed 0.79 0.63 0.79 35.00 2.00 4.10 0.88 254 0.65 PA 1.5 2.82 6.93 3.70 11.61 6.19 5.00 Total Time of Concentration - Initial Overland Flow - Ti C = Runoff Coefficient Cf = Frequency Adjustment Factor L = Length of Overland Flow (feet) (500' maximum) S = Slope (%) (not in ft/ft) Time of Concentration - Channelized Flow - Tt Slope (%) Ground Cover Type K Velocity (fps) Ground Cover Type K Velocity (fps) Ground Cover Type K Velocity (fps) Ground Cover Type K Velocity (fps) Ground Cover Type K Velocity (fps) Ground Cover Type K Velocity (fps) 0.5 PA 1.4 1.78 GW 1.11 0.91 BG 0.7 0.35 PL 0.5 0.22 TC 0.33 0.15 HG 0.18 0.11 1 PA 1.4 2.51 GW 1.11 1.29 BG 0.7 0.50 PL 0.5 0.32 TC 0.33 0.21 HG 0.18 0.15 2 PA 1.4 3.55 GW 1.11 1.82 BG 0.7 0.71 PL 0.5 0.45 TC 0.33 0.30 HG 0.18 0.21 3 PA 1.4 4.35 GW 1.11 2.23 BG 0.7 0.87 PL 0.5 0.55 TC 0.33 0.37 HG 0.18 0.26 4 PA 1.4 5.02 GW 1.11 2.58 BG 0.7 1.00 PL 0.5 0.63 TC 0.33 0.43 HG 0.18 0.30 5 PA 1.4 5.62 GW 1.11 2.88 BG 0.7 1.12 PL 0.5 0.71 TC 0.33 0.48 HG 0.18 0.34 6 PA 1.4 6.15 GW 1.11 3.16 BG 0.7 1.23 PL 0.5 0.77 TC 0.33 0.52 HG 0.18 0.37 7 PA 1.4 6.65 GW 1.11 3.41 BG 0.7 1.33 PL 0.5 0.84 TC 0.33 0.57 HG 0.18 0.40 8 PA 1.4 7.10 GW 1.11 3.64 BG 0.7 1.42 PL 0.5 0.89 TC 0.33 0.60 HG 0.18 0.43 9 PA 1.4 7.54 GW 1.11 3.86 BG 0.7 1.50 PL 0.5 0.95 TC 0.33 0.64 HG 0.18 0.45 10 PA 1.4 7.94 GW 1.11 4.07 BG 0.7 1.58 PL 0.5 1.00 TC 0.33 0.68 HG 0.18 0.48 20 PA 1.4 11.23 GW 1.11 5.76 BG 0.7 2.24 PL 0.5 1.41 TC 0.33 0.96 HG 0.18 0.68 30 PA 1.4 13.76 GW 1.11 7.06 BG 0.7 2.75 PL 0.5 1.73 TC 0.33 1.17 HG 0.18 0.83 40 PA 1.4 15.89 GW 1.11 8.15 BG 0.7 3.17 PL 0.5 2.00 TC 0.33 1.35 HG 0.18 0.96 50 PA 1.4 17.76 GW 1.11 9.11 BG 0.7 3.54 PL 0.5 2.24 TC 0.33 1.51 HG 0.18 1.07 60 PA 1.4 19.46 GW 1.11 9.98 BG 0.7 3.88 PL 0.5 2.45 TC 0.33 1.66 HG 0.18 1.17 Land Surface Types HG Forest with Heavy Ground Litter & Meadow 0.18 TC Fallow or Minimum Tillage Cultivation 0.33 PL Short Grass Pasture & Lawns 0.5 BG Nearly Bare Ground 0.7 Example Calculation Table Basin or Sub- Basin Total Area (acres) C (2-yr) C (100-yr) Tc (2-yr) Tc (100-yr) I (2-yr) I (100-yr) Q (2-yr) Q (100-yr) Historic 0.79 0.25 0.31 11.53 11.53 2.12 7.37 0.42 1.82 Developed 0.79 0.63 0.79 6.19 5.00 2.88 9.96 1.44 6.22 Total Basin Information Runoff Coefficients - C Time of Concentration - Tc (min) Rainfall Intensity - I (in/hr) Peak Discharge - Q (cfs) APPENDIX C HYDRAULIC COMPUTATIONS Detention Volume - Mass Balance Method -100-yr (Major Storm) Input 1.00 1.00 0.42 cfs 0.79 acres Results 0.170 0.170 Rainfall Duration (min) Rainfall Intensity (in/hr) Qin (cfs) Volumein (ft 3 ) Qout (cfs) Volumeout (ft 3 ) Volume detained (acre-feet) 5 9.96 7.87 2360.52 0.42 125.61 0.051 10 7.74 6.11 3668.76 0.42 251.22 0.078 15 6.52 5.15 4635.72 0.42 376.83 0.098 20 5.61 4.43 5318.28 0.42 502.44 0.111 25 4.97 3.92 5887.08 0.42 628.05 0.121 30 4.52 3.57 6427.44 0.42 753.66 0.130 35 4.08 3.22 6768.72 0.42 879.27 0.135 40 3.74 2.95 7081.56 0.42 1004.88 0.140 45 3.45 2.73 7365.96 0.42 1130.49 0.143 50 3.23 2.55 7650.36 0.42 1256.10 0.147 55 3.03 2.40 7906.32 0.42 1381.71 0.150 60 2.86 2.26 8133.84 0.42 1507.32 0.152 65 2.71 2.14 8361.36 0.42 1632.93 0.154 70 2.59 2.04 8588.88 0.42 1758.54 0.157 75 2.48 1.96 8816.40 0.42 1884.15 0.159 80 2.38 1.88 9015.48 0.42 2009.76 0.161 85 2.29 1.81 9214.56 0.42 2135.37 0.163 90 2.21 1.74 9413.64 0.42 2260.98 0.164 95 2.13 1.68 9584.28 0.42 2386.59 0.165 100 2.06 1.63 9783.36 0.42 2512.20 0.167 105 2.00 1.58 9954.00 0.42 2637.81 0.168 110 1.94 1.53 10124.64 0.42 2763.42 0.169 115 1.88 1.49 10266.84 0.42 2889.03 0.169 120 1.835 1.45 10437.48 0.42 3014.64 0.170 125 1.78 1.40 10527.18 0.42 3140.25 0.170 130 1.72 1.36 10607.30 0.42 3265.86 0.169 135 1.67 1.32 10661.19 0.42 3391.47 0.167 140 1.61 1.27 10688.85 0.42 3517.08 0.165 145 1.56 1.23 10690.29 0.42 3642.69 0.162 150 1.50 1.19 10665.49 0.42 3768.30 0.158 155 1.44 1.14 10614.47 0.42 3893.91 0.154 160 1.39 1.10 10537.22 0.42 4019.52 0.150 165 1.33 1.05 10433.74 0.42 4145.13 0.144 170 1.28 1.01 10304.03 0.42 4270.74 0.139 175 1.22 0.97 10148.10 0.42 4396.35 0.132 180 1.17 0.92 9965.93 0.42 4521.96 0.125 Water Quality Capture Volume, WQCV 1. Determine the WQCV in Watershed Inches WQCV = a (0.91I 3-1.19I 2+0.78I ) Where: WQCV = Water Quality Capture Volume, watershed inches a = coefficient corresponding to WQCV drain time I = Imperviousness (%/100) Drain Time (hrs) Coefficient (a ) 12 0.8 24 0.9 40 1.0 Coefficient, a 1.00 Imperviousness, I 90 WQCV = 0.40 watershed inches 2. Determine the required storage volume in Acre-Feet V = (WQCV/12)A Where: V = Required Storage Volume, acre-feet A = Tributary catchment area upstream, acres Area, A 0.79 acres V = 0.026 acre-feet Drain Time Coefficients Extended Detention Basin Outlet Structure Orifice Sizing 1. 100-yr Orifice (using orifice equation) a. Use Orifice Equation to solve for orifice diamter Q = Co A√2gh Where: Q = flow rate or allowable discharge, cfs Co = orifice coefficient, typically 0.61 A = cross-sectional area, ft 2 A0 = 88V (0.95/H^0.085) g = gravitational constant, 32.2 ft/sec 2 TD S 0.09 H (2.6/S^0.3) h = water surface elevation minus elevation of centroid of orifice, ft Q = 0.42 cfs Cd = 0.61 dimensionless h = 4.66 ft A = 0.040 ft 2 orifice diameter = 2.70 inches 2. WQCV Perforated Orifice a. Determine the required area per row of orifices a = WQCV 0.013DWQ 2 + 0.22DWQ -0.10 Where: Ao = Area per row of orifices spaced on 4" centers, in 2 WQCV = Water Quality Capture Volume or "Volume", acre-ft DWQ = Depth of volume, ft V = 0.026 acre-ft DWQ = 1.63 ft a = 0.107 in 2 per row or from Figure EDB-3 b. Determine diameter of circular perforations A0 = 0.107 in 2 per row Diameter = 0.370 inches c. Determine number of columns Number of Columns = 1 from Table 6a-1 d. Round Orifice Diameter to nearest 1/16 inch Area per Perforation = 0.1074 in 2 Project: Basin ID: Design Information (Input): Width of Basin Bottom, W = 25.00 ft Right Triangle OR… Length of Basin Bottom, L = 60.00 ft Isosceles Triangle X OR… Dam Side-slope (H:V), Zd = 4.00 ft/ft Rectangle OR… Circle / Ellipse OR… Irregular (Use Overide values in cells G32:G52) MINOR MAJOR Storage Requirement from Sheet 'Modified FAA': 0.03 0.19 acre-ft. Stage-Storage Relationship: Storage Requirement from Sheet 'Hydrograph': acre-ft. Storage Requirement from Sheet 'Full-Spectrum': acre-ft. Labels Water Side Basin Basin Surface Surface Volume Surface Volume Target Volumes for WQCV, Minor, Surface Slope Width at Length at Area at Area at Below Area at Below for WQCV, Minor, & Major Storage Elevation (H:V) Stage Stage Stage Stage Stage Stage Stage & Major Storage Stages ft ft/ft ft ft ft2 ft2 User ft3 acres acre-ft Volumes (input) (input) Below El. (output) (output) (output) Overide (output) (output) (output) (for goal seek) 4924.90 (input) 25.00 60.00 750.0 5 0.017 0.000 4925.00 4.00 25.98 62.36 810.2 38 7 0.001 0.000 4925.50 4.00 30.90 74.17 1,146.0 371 109 0.009 0.003 4926.00 4.00 35.82 85.97 1,539.9 1,052 465 0.024 0.011 WQCV@4926.47 4926.50 4.00 40.74 97.78 1,991.8 1,851 1,191 0.042 0.027 0.026 4927.00 4.00 45.66 109.59 2,501.9 2,570 2,296 0.059 0.053 4927.50 4.00 50.58 121.39 3,070.0 3,212 3,741 0.074 0.086 4928.00 4.00 55.50 133.20 3,696.2 3,798 5,494 0.087 0.126 100-yr @4928.47 4928.50 4.00 60.42 145.00 4,380.5 4,454 7,557 0.102 0.173 0.170 WQCV+100-yr @4928.70 4929.00 4.00 65.34 156.81 5,122.8 5,378 10,015 0.123 0.230 0.196 4929.50 4.00 70.26 168.62 5,923.2 6,496 12,983 0.149 0.298 4930.00 4.00 75.18 180.42 6,781.7 7,404 16,458 0.170 0.378 4930.25 4.00 77.64 186.33 7,232.7 7,898 18,371 0.181 0.422 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A 4.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Project: Basin ID: STAGE-STORAGE SIZING FOR DETENTION BASINS 4923.75 4924.75 4925.75 4926.75 4927.75 4928.75 4929.75 4930.75 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 Stage (ft. elev.) Storage (acre-feet) STAGE-STORAGE CURVE FOR THE POND 15298UD-Detention_v2.35Disturbedarea.xls, Basin 8/22/2017, 2:35 PM Project: Basin ID: Design Information (Input): #1 Horiz. #2 Horiz. #1 Vert. #2 Vert. Circular Opening: Diameter in Inches Dia. = 2.70 inches OR Rectangular Opening: Width in Feet W = 3.00 ft. Length (Height for Vertical) L or H = 3.00 ft. Percentage of Open Area After Trash Rack Reduction % open = 50 100 % Orifice Coefficient Co = 0.67 0.67 Weir Coefficient Cw = 3.00 Orifice Elevation (Bottom for Vertical) Eo = 4926.50 4,924.20 ft. Calculation of Collection Capacity: Net Opening Area (after Trash Rack Reduction) Ao = 4.50 0.04 sq. ft. OPTIONAL: User-Overide Net Opening Area Ao = sq. ft. Perimeter as Weir Length Lw = 9.00 ft. OPTIONAL: User-Overide Weir Length Lw = ft. Top Elevation of Vertical Orifice Opening, Top = 4924.43 ft. Center Elevation of Vertical Orifice Opening, Cen = 4924.31 ft. Horizontal Orifices Vertical Orifices Labels Water WQCV #1 Horiz. #1 Horiz. #2 Horiz. #2 Horiz. #1 Vert. #2 Vert. Total Target Volumes for WQCV, Minor, Surface Plate/Riser Weir Orifice Weir Orifice Collection Collection Collection for WQCV, Minor, & Major Storage Elevation Flow Flow Flow Flow Flow Capacity Capacity Capacity & Major Storage W.S. Elevations ft cfs cfs cfs cfs cfs cfs cfs cfs Volumes (input) (linked) (User-linked) (output) (output) (output) (output) (output) (output) (output) (link for goal seek) 4924.90 0.00 0.00 0.00 0.00 0.00 0.16 0.00 0.00 4925.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.00 4925.50 0.01 0.00 0.00 0.00 0.00 0.23 0.00 0.01 4926.00 0.01 0.00 0.00 0.00 0.00 0.28 0.00 0.01 4926.50 0.01 0.00 0.00 0.00 0.00 0.32 0.00 0.01 4927.00 0.02 9.55 17.11 0.00 0.00 0.35 0.00 0.35 4927.50 0.02 27.00 24.20 0.00 0.00 0.38 0.00 0.38 4928.00 0.02 49.60 29.63 0.00 0.00 0.41 0.00 0.41 4928.50 0.03 76.37 34.22 0.00 0.00 0.44 0.00 0.44 4929.00 0.03 106.73 38.26 0.00 0.00 0.46 0.00 0.46 4929.50 0.03 140.30 41.91 0.00 0.00 0.49 0.00 0.49 4930.00 0.04 176.79 45.27 0.00 0.00 0.51 0.00 0.51 4930.25 0.04 196.07 46.85 0.00 0.00 0.52 0.00 0.52 0.04 #N/A #N/A #N/A #N/A #N/A 0.00 #N/A 0.04 #N/A #N/A #N/A #N/A #N/A 0.00 #N/A 0.04 #N/A #N/A #N/A #N/A #N/A 0.00 #N/A 0.04 #N/A #N/A #N/A #N/A #N/A 0.00 #N/A 0.05 #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A Project: Basin ID: Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO STAGE-DISCHARGE SIZING OF THE WEIRS AND ORIFICES (INLET CONTROL) 4923.75 4924.75 4925.75 4926.75 4927.75 4928.75 4929.75 4930.75 0 0.1 0.2 0.3 0.4 0.5 0.6 Stage (feet, elev.) Discharge (cfs) STAGE-DISCHARGE CURVE FOR THE OUTLET STRUCTURE 15298UD-Detention_v2.35Disturbedarea.xls, Outlet 8/22/2017, 3:15 PM Project: Basin ID: Status: Culvert Data is valid! Design Information (Input): Circular Culvert: Barrel Diameter in Inches D = 15 in. Circular Culvert: Inlet Edge Type (choose from pull-down list) Square End with Headwall OR: Box Culvert: Barrel Height (Rise) in Feet Height (Rise) = ft. Box Culvert: Barrel Width (Span) in Feet Width (Span) = ft. Box Culvert: Inlet Edge Type (choose from pull-down list) Square Edge w/ 90-15 deg. Flared Wingwall Number of Barrels No = 1 Inlet Elevation at Culvert Invert Ielev = 4924.20 ft. elev. Outlet Elevation at Culvert Invert Oelev = 4923.60 ft. elev. Culvert Length in Feet L = 48.0 ft. Manning's Roughness n = 0.0130 Bend Loss Coefficient Kb = 0.00 Exit Loss Coefficient Kx = 1.00 Design Information (calculated): Entrance Loss Coefficient Ke = 0.50 Friction Loss Coefficient Kf = 1.11 Sum of All Loss Coefficients Ks = 2.61 Orifice Inlet Condition Coefficient Cd = 0.86 Minimum Energy Condition Coefficient KElow = -0.09 Calculations of Culvert Capacity (output): Water Surface Tailwater Culvert Culvert Flowrate Controlling Inlet Elevation Surface Inlet-Control Outlet-Control Into Culvert Culvert Equation From Sheet Elevation Flowrate Flowrate From Sheet Flowrate Used "Basin" ft cfs cfs "Outlet" cfs (ft., linked) (input if known) (output) (output) (cfs, linked) (output) (output) 4924.90 4922.50 1.60 3.21 0.00 0.00 Regression Eqn. 4925.00 4922.50 2.00 3.39 0.00 0.00 Regression Eqn. 4925.50 4922.50 4.20 4.26 0.01 0.01 Regression Eqn. 4926.00 4922.50 6.10 5.56 0.01 0.01 Regression Eqn. 4926.50 4922.50 7.50 6.68 0.01 0.01 Regression Eqn. 4927.00 4922.50 8.70 7.62 0.35 0.35 Regression Eqn. 4927.50 4922.50 9.70 8.45 0.38 0.38 Regression Eqn. 4928.00 4922.50 10.70 9.21 0.41 0.41 Orifice Eqn. 4928.50 4922.50 11.50 9.93 0.44 0.44 Orifice Eqn. 4929.00 4922.50 12.30 10.58 0.46 0.46 Orifice Eqn. 4929.50 4922.50 13.00 11.19 0.49 0.49 Orifice Eqn. 4930.00 4922.50 13.70 11.77 0.51 0.51 Orifice Eqn. 4930.25 4922.50 14.00 12.06 0.52 0.52 Orifice Eqn. 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) Project: Basin ID: STAGE-DISCHARGE SIZING OF THE OUTLET CULVERT (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO 4926.00 4926.50 4927.00 4927.50 4928.00 4928.50 4929.00 4929.50 4930.00 4930.50 0.00 0.10 0.20 0.30 0.40 0.50 0.60 Stage (feet, elev.) Discharge (cfs) STAGE-DISCHARGE CURVE FOR THE FINAL OUTLET PIPE CULVERT 15298UD-Detention_v2.35Disturbedarea.xls, Culvert 8/22/2017, 3:16 PM Project: Basin ID: 75.96 4.00000 Design Information (input): Bottom Length of Weir L = 10.00 feet Angle of Side Slope Weir Angle = 75.96 degrees Elev. for Weir Crest EL. Crest = 4,929.00 feet Coef. for Rectangular Weir Cw = 3.00 Coef. for Trapezoidal Weir Ct = 3.00 Calculation of Spillway Capacity (output): Water Rect. Triangle Total Total Surface Weir Weir Spillway Pond Elevation Flowrate Flowrate Release Release ft. cfs cfs cfs cfs (linked) (output) (output) (output) (output) 4924.90 0.00 0.00 0.00 0.00 4925.00 0.00 0.00 0.00 0.00 4925.50 0.00 0.00 0.00 0.01 4926.00 0.00 0.00 0.00 0.01 4926.50 0.00 0.00 0.00 0.01 4927.00 0.00 0.00 0.00 0.35 4927.50 0.00 0.00 0.00 0.38 4928.00 0.00 0.00 0.00 0.41 4928.50 0.00 0.00 0.00 0.44 4929.00 0.00 0.00 0.00 0.46 4929.50 10.61 2.12 12.73 13.22 4930.00 30.00 12.00 42.00 42.51 4930.25 41.93 20.96 62.88 63.40 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Project: Basin ID: STAGE-DISCHARGE SIZING OF THE SPILLWAY Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 4924.9 4925.9 4926.9 4927.9 4928.9 4929.9 4930.9 0 10 20 30 40 50 60 70 Storage (Acre-Feet) Stage (feet, elev.) Pond Discharge (cfs) STAGE-STORAGE-DISCHARGE CURVES FOR THE POND TOTAL DISCHARGE SPILLWAY DISCHARGE POND STORAGE 15298UD-Detention_v2.35Disturbedarea.xls, Spillway 8/22/2017, 3:17 PM Sheet 1 of 2 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia Ia = 100.0 % (100% if all paved and roofed areas upstream of rain garden) B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 1.000 C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV = 0.40 watershed inches (WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i) D) Contributing Watershed Area (including rain garden area) Area = 16,354 sq ft E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = 545 cu ft Vol = (WQCV / 12) * Area F) For Watersheds Outside of the Denver Region, Depth of d6 = in Average Runoff Producing Storm G) For Watersheds Outside of the Denver Region, VWQCV OTHER = cu ft Water Quality Capture Volume (WQCV) Design Volume H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER = cu ft (Only if a different WQCV Design Volume is desired) 2. Basin Geometry A) WQCV Depth (12-inch maximum) DWQCV = 12 in B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical) Z = 4.00 ft / ft (Use "0" if rain garden has vertical walls) C) Mimimum Flat Surface Area AMin = 327 sq ft D) Actual Flat Surface Area AActual = 465 sq ft E) Area at Design Depth (Top Surface Area) ATop = 900 sq ft F) Rain Garden Total Volume VT= 683 cu ft (VT= ((ATop + AActual) / 2) * Depth) 3. Growing Media 4. Underdrain System A) Are underdrains provided? B) Underdrain system orifice diameter for 12 hour drain time i) Distance From Lowest Elevation of the Storage y = ft Volume to the Center of the Orifice ii) Volume to Drain in 12 Hours Vol12 = N/A cu ft iii) Orifice Diameter, 3/8" Minimum DO = N/A in Design Procedure Form: Rain Garden (RG) Todd Rand, PE Baseline Engineering Corporation August 18, 2017 Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO UD-BMP (Version 3.06, November 2016) Choose One Choose One 18" Rain Garden Growing Media Other (Explain): YES NO UD-BMP_v3.06.xlsm, RG 8/18/2017, 10:59 AM Sheet 2 of 2 Designer: Company: Date: Project: Location: 5. Impermeable Geomembrane Liner and Geotextile Separator Fabric A) Is an impermeable liner provided due to proximity of structures or groundwater contamination? 6. Inlet / Outlet Control A) Inlet Control 7. Vegetation 8. Irrigation A) Will the rain garden be irrigated? Notes: Design Procedure Form: Rain Garden (RG) Todd Rand, PE Baseline Engineering Corporation August 18, 2017 Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO Choose One Choose One Choose One Sheet Flow- No Energy Dissipation Required Concentrated Flow- Energy Dissipation Provided Plantings Seed (Plan for frequent weed control) Sand Grown or Other High Infiltration Sod Choose One YES NO YES NO UD-BMP_v3.06.xlsm, RG 8/18/2017, 10:59 AM APPENDIX D NRCS SOILS MAP United States Department of Agriculture A product of the National Cooperative Soil Survey, a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local participants Custom Soil Resource Report for Larimer County Area, Colorado CBA Fort Collins Prospect Site Natural Resources Conservation Service March 17, 2017 Preface Soil surveys contain information that affects land use planning in survey areas. They highlight soil limitations that affect various land uses and provide information about the properties of the soils in the survey areas. Soil surveys are designed for many different users, including farmers, ranchers, foresters, agronomists, urban planners, community officials, engineers, developers, builders, and home buyers. Also, conservationists, teachers, students, and specialists in recreation, waste disposal, and pollution control can use the surveys to help them understand, protect, or enhance the environment. Various land use regulations of Federal, State, and local governments may impose special restrictions on land use or land treatment. Soil surveys identify soil properties that are used in making various land use or land treatment decisions. The information is intended to help the land users identify and reduce the effects of soil limitations on various land uses. The landowner or user is responsible for identifying and complying with existing laws and regulations. Although soil survey information can be used for general farm, local, and wider area planning, onsite investigation is needed to supplement this information in some cases. Examples include soil quality assessments (http://www.nrcs.usda.gov/wps/ portal/nrcs/main/soils/health/) and certain conservation and engineering applications. For more detailed information, contact your local USDA Service Center (https://offices.sc.egov.usda.gov/locator/app?agency=nrcs) or your NRCS State Soil Scientist (http://www.nrcs.usda.gov/wps/portal/nrcs/detail/soils/contactus/? cid=nrcs142p2_053951). Great differences in soil properties can occur within short distances. Some soils are seasonally wet or subject to flooding. Some are too unstable to be used as a foundation for buildings or roads. Clayey or wet soils are poorly suited to use as septic tank absorption fields. A high water table makes a soil poorly suited to basements or underground installations. The National Cooperative Soil Survey is a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local agencies. The Natural Resources Conservation Service (NRCS) has leadership for the Federal part of the National Cooperative Soil Survey. Information about soils is updated periodically. Updated information is available through the NRCS Web Soil Survey, the site for official soil survey information. The U.S. Department of Agriculture (USDA) prohibits discrimination in all its programs and activities on the basis of race, color, national origin, age, disability, and where applicable, sex, marital status, familial status, parental status, religion, sexual orientation, genetic information, political beliefs, reprisal, or because all or a part of an individual's income is derived from any public assistance program. (Not all prohibited bases apply to all programs.) Persons with disabilities who require 2 alternative means for communication of program information (Braille, large print, audiotape, etc.) should contact USDA's TARGET Center at (202) 720-2600 (voice and TDD). To file a complaint of discrimination, write to USDA, Director, Office of Civil Rights, 1400 Independence Avenue, S.W., Washington, D.C. 20250-9410 or call (800) 795-3272 (voice) or (202) 720-6382 (TDD). USDA is an equal opportunity provider and employer. 3 Contents Preface.................................................................................................................... 2 Soil Map.................................................................................................................. 5 Soil Map................................................................................................................6 Legend..................................................................................................................7 Map Unit Legend.................................................................................................. 8 Map Unit Descriptions.......................................................................................... 8 Larimer County Area, Colorado...................................................................... 10 53—Kim loam, 1 to 3 percent slopes.......................................................... 10 54—Kim loam, 3 to 5 percent slopes...........................................................11 60—Larim gravelly sandy loam, 5 to 40 percent slopes..............................12 101—Stoneham loam, 1 to 3 percent slopes.............................................. 14 References............................................................................................................16 4 Soil Map The soil map section includes the soil map for the defined area of interest, a list of soil map units on the map and extent of each map unit, and cartographic symbols displayed on the map. Also presented are various metadata about data used to produce the map, and a description of each soil map unit. 5 6 Custom Soil Resource Report Soil Map 4490720 4490740 4490760 4490780 4490800 4490820 4490840 4490860 4490720 4490740 4490760 4490780 4490800 4490820 4490840 4490860 496430 496450 496470 496490 496510 496530 496430 496450 496470 496490 496510 496530 40° 34' 6'' N 105° 2' 32'' W 40° 34' 6'' N 105° 2' 26'' W 40° 34' 1'' N 105° 2' 32'' W 40° 34' 1'' N 105° 2' 26'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 35 70 140 210 Feet 0 10 20 40 60 Meters Map Scale: 1:820 if printed on A portrait (8.5" x 11") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more Map Unit Legend Larimer County Area, Colorado (CO644) Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI 53 Kim loam, 1 to 3 percent slopes 0.2 13.4% 54 Kim loam, 3 to 5 percent slopes 0.7 39.8% 60 Larim gravelly sandy loam, 5 to 40 percent slopes 0.6 30.6% 101 Stoneham loam, 1 to 3 percent slopes 0.3 16.2% Totals for Area of Interest 1.9 100.0% Map Unit Descriptions The map units delineated on the detailed soil maps in a soil survey represent the soils or miscellaneous areas in the survey area. The map unit descriptions, along with the maps, can be used to determine the composition and properties of a unit. A map unit delineation on a soil map represents an area dominated by one or more major kinds of soil or miscellaneous areas. A map unit is identified and named according to the taxonomic classification of the dominant soils. Within a taxonomic class there are precisely defined limits for the properties of the soils. On the landscape, however, the soils are natural phenomena, and they have the characteristic variability of all natural phenomena. Thus, the range of some observed properties may extend beyond the limits defined for a taxonomic class. Areas of soils of a single taxonomic class rarely, if ever, can be mapped without including areas of other taxonomic classes. Consequently, every map unit is made up of the soils or miscellaneous areas for which it is named and some minor components that belong to taxonomic classes other than those of the major soils. Most minor soils have properties similar to those of the dominant soil or soils in the map unit, and thus they do not affect use and management. These are called noncontrasting, or similar, components. They may or may not be mentioned in a particular map unit description. Other minor components, however, have properties and behavioral characteristics divergent enough to affect use or to require different management. These are called contrasting, or dissimilar, components. They generally are in small areas and could not be mapped separately because of the scale used. Some small areas of strongly contrasting soils or miscellaneous areas are identified by a special symbol on the maps. If included in the database for a given area, the contrasting minor components are identified in the map unit descriptions along with some characteristics of each. A few areas of minor components may not have been observed, and consequently they are not mentioned in the descriptions, especially where the pattern was so complex that it was impractical to make enough observations to identify all the soils and miscellaneous areas on the landscape. The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The objective of mapping is not to delineate Custom Soil Resource Report 8 pure taxonomic classes but rather to separate the landscape into landforms or landform segments that have similar use and management requirements. The delineation of such segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, however, onsite investigation is needed to define and locate the soils and miscellaneous areas. An identifying symbol precedes the map unit name in the map unit descriptions. Each description includes general facts about the unit and gives important soil properties and qualities. Soils that have profiles that are almost alike make up a soil series. Except for differences in texture of the surface layer, all the soils of a series have major horizons that are similar in composition, thickness, and arrangement. Soils of one series can differ in texture of the surface layer, slope, stoniness, salinity, degree of erosion, and other characteristics that affect their use. On the basis of such differences, a soil series is divided into soil phases. Most of the areas shown on the detailed soil maps are phases of soil series. The name of a soil phase commonly indicates a feature that affects use or management. For example, Alpha silt loam, 0 to 2 percent slopes, is a phase of the Alpha series. Some map units are made up of two or more major soils or miscellaneous areas. These map units are complexes, associations, or undifferentiated groups. A complex consists of two or more soils or miscellaneous areas in such an intricate pattern or in such small areas that they cannot be shown separately on the maps. The pattern and proportion of the soils or miscellaneous areas are somewhat similar in all areas. Alpha-Beta complex, 0 to 6 percent slopes, is an example. An association is made up of two or more geographically associated soils or miscellaneous areas that are shown as one unit on the maps. Because of present or anticipated uses of the map units in the survey area, it was not considered practical or necessary to map the soils or miscellaneous areas separately. The pattern and relative proportion of the soils or miscellaneous areas are somewhat similar. Alpha-Beta association, 0 to 2 percent slopes, is an example. An undifferentiated group is made up of two or more soils or miscellaneous areas that could be mapped individually but are mapped as one unit because similar interpretations can be made for use and management. The pattern and proportion of the soils or miscellaneous areas in a mapped area are not uniform. An area can be made up of only one of the major soils or miscellaneous areas, or it can be made up of all of them. Alpha and Beta soils, 0 to 2 percent slopes, is an example. Some surveys include miscellaneous areas. Such areas have little or no soil material and support little or no vegetation. Rock outcrop is an example. Custom Soil Resource Report 9 Larimer County Area, Colorado 53—Kim loam, 1 to 3 percent slopes Map Unit Setting National map unit symbol: jpwx Elevation: 4,800 to 5,600 feet Mean annual precipitation: 13 to 15 inches Mean annual air temperature: 48 to 50 degrees F Frost-free period: 135 to 150 days Farmland classification: Prime farmland if irrigated Map Unit Composition Kim and similar soils: 90 percent Minor components: 10 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Kim Setting Landform: Fans Landform position (three-dimensional): Base slope Down-slope shape: Linear Across-slope shape: Linear Parent material: Mixed alluvium Typical profile H1 - 0 to 7 inches: loam H2 - 7 to 60 inches: loam, clay loam, sandy clay loam H2 - 7 to 60 inches: H2 - 7 to 60 inches: Properties and qualities Slope: 1 to 3 percent Depth to restrictive feature: More than 80 inches Natural drainage class: Well drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.60 to 2.00 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum in profile: 15 percent Salinity, maximum in profile: Nonsaline to slightly saline (0.0 to 4.0 mmhos/cm) Available water storage in profile: Very high (about 26.5 inches) Interpretive groups Land capability classification (irrigated): 2e Land capability classification (nonirrigated): 4e Hydrologic Soil Group: B Ecological site: Loamy Plains (R067XY002CO) Hydric soil rating: No Custom Soil Resource Report 10 Minor Components Fort collins Percent of map unit: 6 percent Hydric soil rating: No Stoneham Percent of map unit: 3 percent Hydric soil rating: No Aquic haplustolls Percent of map unit: 1 percent Landform: Swales Hydric soil rating: Yes 54—Kim loam, 3 to 5 percent slopes Map Unit Setting National map unit symbol: jpwy Elevation: 4,800 to 5,600 feet Mean annual precipitation: 13 to 15 inches Mean annual air temperature: 48 to 50 degrees F Frost-free period: 135 to 150 days Farmland classification: Farmland of statewide importance Map Unit Composition Kim and similar soils: 90 percent Minor components: 10 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Kim Setting Landform: Fans Landform position (three-dimensional): Base slope Down-slope shape: Linear Across-slope shape: Linear Parent material: Mixed alluvium Typical profile H1 - 0 to 7 inches: loam H2 - 7 to 60 inches: loam, clay loam, sandy clay loam H2 - 7 to 60 inches: H2 - 7 to 60 inches: Properties and qualities Slope: 3 to 5 percent Depth to restrictive feature: More than 80 inches Natural drainage class: Well drained Runoff class: Low Custom Soil Resource Report 11 Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.60 to 2.00 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum in profile: 15 percent Salinity, maximum in profile: Nonsaline to slightly saline (0.0 to 4.0 mmhos/cm) Available water storage in profile: Very high (about 26.5 inches) Interpretive groups Land capability classification (irrigated): 3e Land capability classification (nonirrigated): 4e Hydrologic Soil Group: B Ecological site: Loamy Plains (R067XY002CO) Hydric soil rating: No Minor Components Thedalund Percent of map unit: 4 percent Hydric soil rating: No Stoneham Percent of map unit: 3 percent Hydric soil rating: No Fort collins Percent of map unit: 2 percent Hydric soil rating: No Aquic haplustolls Percent of map unit: 1 percent Landform: Swales Hydric soil rating: Yes 60—Larim gravelly sandy loam, 5 to 40 percent slopes Map Unit Setting National map unit symbol: jpx5 Elevation: 4,800 to 6,300 feet Mean annual precipitation: 13 to 15 inches Mean annual air temperature: 47 to 49 degrees F Frost-free period: 135 to 150 days Farmland classification: Not prime farmland Map Unit Composition Larim and similar soils: 85 percent Minor components: 15 percent Estimates are based on observations, descriptions, and transects of the mapunit. Custom Soil Resource Report 12 Description of Larim Setting Landform: Benches, terraces, fans Landform position (three-dimensional): Side slope, base slope, riser Down-slope shape: Linear Across-slope shape: Linear Parent material: Mixed alluvium Typical profile H1 - 0 to 4 inches: gravelly sandy loam H2 - 4 to 15 inches: very gravelly sandy clay loam, very gravelly clay loam H2 - 4 to 15 inches: very gravelly loamy sand, very gravelly sand H3 - 15 to 60 inches: H3 - 15 to 60 inches: Properties and qualities Slope: 5 to 40 percent Depth to restrictive feature: More than 80 inches Natural drainage class: Well drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.60 to 2.00 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum in profile: 15 percent Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Available water storage in profile: Low (about 5.4 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 6e Hydrologic Soil Group: B Ecological site: Gravelly Foothill (R049BY214CO) Hydric soil rating: No Minor Components Midway Percent of map unit: 8 percent Hydric soil rating: No Tassel Percent of map unit: 7 percent Hydric soil rating: No Custom Soil Resource Report 13 101—Stoneham loam, 1 to 3 percent slopes Map Unit Setting National map unit symbol: jptt Elevation: 4,800 to 5,600 feet Mean annual precipitation: 13 to 15 inches Mean annual air temperature: 48 to 50 degrees F Frost-free period: 135 to 150 days Farmland classification: Prime farmland if irrigated Map Unit Composition Stoneham and similar soils: 90 percent Minor components: 10 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Stoneham Setting Landform: Benches, terraces Landform position (three-dimensional): Base slope, tread Down-slope shape: Linear Across-slope shape: Linear Parent material: Mixed alluvium and/or eolian deposits Typical profile H1 - 0 to 4 inches: loam H2 - 4 to 10 inches: clay loam, sandy clay loam, loam H2 - 4 to 10 inches: loam, clay loam, sandy clay loam H2 - 4 to 10 inches: H3 - 10 to 60 inches: H3 - 10 to 60 inches: H3 - 10 to 60 inches: Properties and qualities Slope: 1 to 3 percent Depth to restrictive feature: More than 80 inches Natural drainage class: Well drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.60 to 2.00 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum in profile: 15 percent Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Available water storage in profile: Very high (about 27.5 inches) Interpretive groups Land capability classification (irrigated): 2e Custom Soil Resource Report 14 Land capability classification (nonirrigated): 3e Hydrologic Soil Group: B Ecological site: Loamy Plains (R067XY002CO) Hydric soil rating: No Minor Components Kim Percent of map unit: 5 percent Hydric soil rating: No Fort collins Percent of map unit: 5 percent Hydric soil rating: No Custom Soil Resource Report 15 References American Association of State Highway and Transportation Officials (AASHTO). 2004. Standard specifications for transportation materials and methods of sampling and testing. 24th edition. American Society for Testing and Materials (ASTM). 2005. Standard classification of soils for engineering purposes. ASTM Standard D2487-00. Cowardin, L.M., V. Carter, F.C. Golet, and E.T. LaRoe. 1979. Classification of wetlands and deep-water habitats of the United States. U.S. Fish and Wildlife Service FWS/OBS-79/31. Federal Register. July 13, 1994. Changes in hydric soils of the United States. Federal Register. September 18, 2002. Hydric soils of the United States. Hurt, G.W., and L.M. Vasilas, editors. Version 6.0, 2006. Field indicators of hydric soils in the United States. National Research Council. 1995. Wetlands: Characteristics and boundaries. Soil Survey Division Staff. 1993. Soil survey manual. Soil Conservation Service. U.S. Department of Agriculture Handbook 18. http://www.nrcs.usda.gov/wps/portal/ nrcs/detail/national/soils/?cid=nrcs142p2_054262 Soil Survey Staff. 1999. Soil taxonomy: A basic system of soil classification for making and interpreting soil surveys. 2nd edition. Natural Resources Conservation Service, U.S. Department of Agriculture Handbook 436. http:// www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?cid=nrcs142p2_053577 Soil Survey Staff. 2010. Keys to soil taxonomy. 11th edition. U.S. Department of Agriculture, Natural Resources Conservation Service. http:// www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?cid=nrcs142p2_053580 Tiner, R.W., Jr. 1985. Wetlands of Delaware. U.S. Fish and Wildlife Service and Delaware Department of Natural Resources and Environmental Control, Wetlands Section. United States Army Corps of Engineers, Environmental Laboratory. 1987. Corps of Engineers wetlands delineation manual. Waterways Experiment Station Technical Report Y-87-1. United States Department of Agriculture, Natural Resources Conservation Service. National forestry manual. http://www.nrcs.usda.gov/wps/portal/nrcs/detail/soils/ home/?cid=nrcs142p2_053374 United States Department of Agriculture, Natural Resources Conservation Service. National range and pasture handbook. http://www.nrcs.usda.gov/wps/portal/nrcs/ detail/national/landuse/rangepasture/?cid=stelprdb1043084 16 United States Department of Agriculture, Natural Resources Conservation Service. National soil survey handbook, title 430-VI. http://www.nrcs.usda.gov/wps/portal/ nrcs/detail/soils/scientists/?cid=nrcs142p2_054242 United States Department of Agriculture, Natural Resources Conservation Service. 2006. Land resource regions and major land resource areas of the United States, the Caribbean, and the Pacific Basin. U.S. Department of Agriculture Handbook 296. http://www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/? cid=nrcs142p2_053624 United States Department of Agriculture, Soil Conservation Service. 1961. Land capability classification. U.S. Department of Agriculture Handbook 210. http:// www.nrcs.usda.gov/Internet/FSE_DOCUMENTS/nrcs142p2_052290.pdf Custom Soil Resource Report 17 APPENDIX E PROPOSED DRAINAGE PLAN 5,140 SF AUTOMOTIVE REPAIR FACILITY FFE=4932.64' accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 11, Sep 23, 2016 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 22, 2011—Apr 28, 2011 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Custom Soil Resource Report 7 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A STAGE-DISCHARGE SIZING OF THE SPILLWAY Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO 15298UD-Detention_v2.35Disturbedarea.xls, Spillway 8/22/2017, 3:17 PM 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) 0.00 0.00 0.00 0.00 #N/A #N/A No Flow (WS < inlet) STAGE-DISCHARGE SIZING OF THE OUTLET CULVERT (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO 15298UD-Detention_v2.35Disturbedarea.xls, Culvert 8/22/2017, 3:16 PM #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 0.00 #N/A Routing 3: Single Stage - Water flows through WQCV plate and #1 horizontal opening into #1 vertical opening. This flow will be applied to culvert sheet (#2 vertical & horizontal openings is not used). STAGE-DISCHARGE SIZING OF THE WEIRS AND ORIFICES (INLET CONTROL) Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO Current Routing Order is #3 W.S. EL. WQ W.S. EL. Minor W.S. EL. Major WQ H1 H2 V1 V2 Routing Order #1 (Standard) V1 W.S. EL. WQ W.S. EL. Design Storm WQ H1 Routing Order #3 (Single Stage) Routing Order #4 V2 V1 H1 WQ W.S. EL. Major W.S. EL. Minor W.S. EL. WQ W.S. EL. Emergency Spillway Emergency Overflow into Pipe- H2 V2 H1 WQ W.S. EL. Major W.S. EL. Minor W.S. EL. WQ V1 Routing Order #2 15298UD-Detention_v2.35Disturbedarea.xls, Outlet 8/22/2017, 3:15 PM #N/A #N/A STAGE-STORAGE SIZING FOR DETENTION BASINS Christian Brothers Automotive 1500 Academy Court, Fort Collins, CO Check Basin Shape 15298UD-Detention_v2.35Disturbedarea.xls, Basin 8/22/2017, 2:35 PM Diameter per Perforation = 0.370 inches Actual Perforation Diameter = 3/8 inches user input (round to nearest 1/16th inch) Actual Area per Perforation = 0.1104 in 2 Actual Area per Row = 0.1104 in 2 per row Minimum Steel Plate Thickness = 1/4 inches from Figure 5 0.0625 1/16 0.1250 1/8 0.1875 3/16 0.2500 1/4 0.3125 5/16 0.3750 3/8 0.4375 7/16 0.5000 1/2 0.5625 9/16 0.6250 5/8 0.6875 11/16 0.7500 3/4 0.8125 13/16 0.8750 7/8 0.9375 15/16 1.0000 1 e. Trach Rack Opening Width Max Diameter of Perforations = 0.3750 inches DWQ = 1.86 ft Width of Trash Rack per Column of Holes = 3 inches user input from Table 6a-1 Total Trash Rack Opening Width = 3 inches Total Trash Rack Height = 24.32 inches Trash Rack Design Specs = use Table 6a-2 Diameter Conversion from decimal to architectural Micropools are typically not allowed in Fort Collins. Perforated orifice plate must be configured such that bottom orifice is at the very bottom of the plate and is a half perforation, like shown. Pond Bottom 185 1.11 0.88 9757.54 0.42 4647.57 0.117 190 1.06 0.84 9522.92 0.42 4773.18 0.109 195 1.00 0.79 9262.07 0.42 4898.79 0.100 200 0.95 0.75 8974.99 0.42 5024.40 0.091 205 0.89 0.70 8661.69 0.42 5150.01 0.081 210 0.84 0.66 8322.15 0.42 5275.62 0.070 215 0.78 0.62 7956.39 0.42 5401.23 0.059 220 0.73 0.57 7564.40 0.42 5526.84 0.047 225 0.67 0.53 7146.18 0.42 5652.45 0.034 230 0.61 0.49 6701.74 0.42 5778.06 0.021 235 0.56 0.44 6231.06 0.42 5903.67 0.008 240 0.50 0.40 5734.16 0.42 6029.28 -0.007 City of Fort Collins Criteria (120%) Runoff Coefficient, C = Frequency Factor, Cf = 2-yr Release, Qout = Area = Detention Volume Requirement (acre-feet) GW Grassed Waterway 1.11 PA Paved Area (Sheet Flow) & Shallow Gutter Flow 1.4 Total Time of Concentration (Tc ) = Initial Overland Flow (Ti ) + Channelized Flow (Tt ) Tc = Ti + Tt **Tc Maximum (check for Urbanized Basins) (L/180) + 10 *Tc Minimum 5 minute minimum Basin Information Runoff Coefficients Time of Concentration - Initial Overland Flow - Ti (minutes) Time of Concentration - Channelized Flow - Tt (minutes) Time of Concentration - Total - Tc (minutes) 0.10 1.00 10.00 100.00 0.1 1 10 100 Series1 Series2 Series3 Series4 Series5 Series6