August 23, 2017
Ryan Sagar
VERIZON WIRELESS
1196 GRANT ST UNIT 313
Denver, CO 80203
RE: FTC Eastside Park SC, PDP170029, Round Number 1
Comment Summary:
Department: Environmental Planning
Contact: Stephanie Blochowiak, 970-416-4290, sblochowiak@fcgov.com
Topic: General
08/14/2017: Generally, an Ecological Characterization Study (ECS) is required by
Section 3.4.1 (D)(1) as the site is within 500 feet of a known natural habitats and
features (Springer Natural Area and associated habitat). However, as there is
intervening infrastructure between the feature and this property the ECS is waived
for this site.
Comment Number: 1 Comment Originated: 08/14/2017
08/14/2017: If landscape updates are required with this development: note City of
Fort Collins Land Use Code [Section 3.2.1 (E)(3)], requires that to the extent
reasonably feasible, all plans be designed to incorporate water conservation
materials and techniques. This includes use of low-water-use plants and grasses in
landscaping or re-landscaping and reducing bluegrass lawns as much as possible.
Native plants and wildlife-friendly (ex: pollinators, butterflies, songbirds) landscaping
and maintenance are also encouraged. Please refer to the Fort Collins Native Plants
document available online and published by the City of Fort Collins Natural Areas
Department for guidance on native plants is:
http://www.fcgov.com/naturalareas/pdf/nativeplants2013.pdf. Also see the City of
Fort Collins Plant List : https://www.fcgov.com/forestry/plant_list.pdf.
Comment Number: 2 Comment Originated: 08/14/2017
Please see the following summary of comments from City staff and outside reviewing agencies for
your submittal of the above referenced project. If you have questions about any comments, you may
contact the individual commenter or direct your questions through the Project Planner, Kai Kleer, at
970-416-4284 or kkleer@fcgov.com.
Page 1 of 6
08/14/2017: If lighting updates will be incorporated into this development: note that
especially for LED light fixtures, cooler color temperatures are harsher at night and
cause more disruption to circadian (biological) rhythms for both humans and wildlife.
Warmer color temperature (warm white, 3000K or less) for any LED light fixtures is
preferred. Please also consider fixtures with dimming capabilities so that light levels
can be adjusted as needed. Site light sources shall be fully shielded and
down-directional to minimize up-light, light spillage and glare [see LUC 3.2.4(D)(3)].
For further information regarding health effects please see:
http://darksky.org/ama-report-affirms-human-health-impacts-from-leds/
Comment Number: 3 Comment Originated: 08/14/2017
08/14/2017: If any trees are to be impacted during construction or as part of this
development: note LUC Section 3.2.1(C) requiring developments to submit a
landscape and tree protection plan, and if receiving water service from the City, an
irrigation plan, that: "...(4) protects significant trees, natural systems, and habitat,
and (5) enhances the pedestrian environment.¿ Note that a significant tree is
defined as a tree having DBH (Diameter at Breast Height) of six inches or more. If
any of the trees within this site have a DBH of greater than six inches, a review of
the trees shall be conducted with Tim Buchanan, City Forester (970-221-6361 or
tbuchanan@fcgov.com) to determine the status of the existing trees and any
mitigation requirements that could result from the proposed development.
Comment Number: 4 Comment Originated: 08/14/2017
Department: Internal Services
Contact: Sarah Carter, 970-416-2748, scarter@fcgov.com
Topic: Building Insp Plan Review
08/11/2017: Construction shall comply with adopted codes as amended. Current
adopted codes are:
2015 International Building Code (IBC)
2015 International Residential Code (IRC)
2015 International Energy Conservation Code (IECC)
2015 International Mechanical Code (IMC)
2015 International Fuel Gas Code (IFGC)
2015 International Plumbing Code (IPC) as amended by the State of Colorado
2017 National Electrical Code (NEC) as amended by the State of Colorado
Fort Collins has amendments to most of the codes listed above. See the
fcgov.com/building web page to view them.
Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2017.
Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load: 129vult or 100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5
Energy Code Use
1. Single Family; Duplex; Townhomes: 2015 IRC Chapter 11 or 2015 IECC.
2. Multi-family and Condominiums 3 stories max: 2015 IECC residential chapter.
3. Commercial and Multi-family 4 stories and taller: 2015 IECC commercial chapter.
Comment Number: 1 Comment Originated: 08/11/2017
Department: Light And Power
Contact: Coy Althoff, 970-224-6150, CAlthoff@fcgov.com
Topic: General
Page 2 of 6
08/22/2017: Light and Power can serve the proposed site, but not based on the
current site plan. That plan proposes to serve the site with power from the north side
of Rivendale Dr. However, the existing U. G. cable has been abandoned in place and
de-energized. A recommendation would be to utilize an existing 300KVA transformer
located on the NW side of the property and extending a secondary service to the
proposed Tower location.
Comment Number: 1 Comment Originated: 08/22/2017
08/22/2017: Any changes to the existing electric capacity and or location will initiate
system modification charges. Charges like this will be billed T&M only. Please
coordinate power requirements with Light and Power Engineering at 221-6700.
Comment Number: 2 Comment Originated: 08/22/2017
08/22/2017: b.) Please provide a one line diagram and a C-1 form to Light and
Power Engineering. The C-1 form can be found at:
http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1Form.pdf
Comment Number: 3 Comment Originated: 08/22/2017
08/22/2017: As your project begins to move forward please contact Light and Power
Engineering to coordinate the transformer and electric meter locations, please show
the locations on the utility plans.
Comment Number: 4 Comment Originated: 08/22/2017
08/22/2017: You may contact FCU Light & Power, project engineering if you have
questions. (970) 221-6700. You may reference Light & Power’s Electric Service
Standards at
http://www.fcgov.com/utilities/img/site_specific/uploads/ElectricServiceStandards_F
INAL_18November2016_Amendment.pdf
You may reference our policies, development charge processes, and use our fee
estimator at http://www.fcgov.com/utilities/business/builders-and-developers
Comment Number: 5 Comment Originated: 08/22/2017
Department: PFA
Contact: Cal Sheesley, 970-416-2599, csheesley@poudre-fire.org
Topic: General
08/22/2017: FIRE LANES
Fire access is required to within 150' of all exterior portions of any facility as
measured by an approved route around the perimeter. When measured from
Rivendale Rd, access requirements appear to be met.
Code language follows:
> IFC 503.1.1: Approved fire Lanes shall be provided for every facility, building or
portion of a building hereafter constructed or moved into or within the jurisdiction.
The fire apparatus access road shall comply with the requirements of this section
and shall extend to within 150 feet of all portions of the facility and all portions of the
exterior walls of the first story of the building as measured by an approved route
around the exterior of the building or facility. When any portion of the facility or any
portion of an exterior wall of the first story of the building is located more than 150
feet from fire apparatus access, the fire code official is authorized to increase the
dimension if the building is equipped throughout with an approved, automatic
fire-sprinkler system.
Comment Number: 1 Comment Originated: 08/22/2017
Page 3 of 6
08/22/2017: WATER SUPPLY
Hydrant spacing and flow must meet minimum requirements based on type of
occupancy. A hydrant is required within 300' of any Commercial Building as
measured along an approved path of vehicle travel. The hydrant located at the
terminus of Rivendale Rd meets hydrant location requirements for this development.
Code language follows:
COMMERCIAL REQUIREMENTS
> IFC 507.5 and PFA Policy: Hydrants to provide 1,500 gpm at 20 psi residual
pressure, spaced not further than 300 feet to the building, on 600-foot centers
thereafter
Comment Number: 2 Comment Originated: 08/22/2017
08/22/2017: PREMISE IDENTIFICATION: ADDRESS POSTING & WAYFINDING
The address shall be posted on the proposed structure to aid in wayfinding. Per
Google Earth, it is unclear if signage requirements have been met an additional
signage may be deemed necessary at time of inspection. This may include signage
located at the intersection of Riverside and Rivendale to aid in wayfinding.
Code language follows:
> IFC 505.1: New and existing buildings shall have approved address numbers,
building numbers or approved building identification placed in a position that is plainly
legible, visible from the street or road fronting the property, and posted with a
minimum of six-inch numerals on a contrasting background. Where access is by
means of a private road and the building cannot be viewed from the public way, a
monument, pole or other sign or means shall be used to identify the structure.
Comment Number: 3 Comment Originated: 08/22/2017
Department: Planning Services
Contact: Kai Kleer, 970-416-4284, kkleer@fcgov.com
Topic: General
08/16/2017:
Landscape Plan will be required. Please provide on separate sheet.
Comment Number: 1 Comment Originated: 08/16/2017
08/16/2017:
Since this facility fronts a public street street trees should be planted along the
roadway in accordance with the policies of the City Forester.
Comment Number: 2 Comment Originated: 08/16/2017
08/16/2017:
To comply with 3.8.13(B) the lease area must show that co-location space is
available for other providers. See redlines and images on Z-2 of plan set.
Comment Number: 3 Comment Originated: 08/16/2017
08/16/2017:
Make sure that the setback is indicated on the site plan. This tower will require 35'
setback from the property line unless it can be demonstrated that the tower will
collapse rather than topple.
Comment Number: 4 Comment Originated: 08/16/2017
Page 4 of 6
08/16/2017:
The antenna must meet our stealth regulations and be mounted on the inside of the
light-pole.
Comment Number: 5 Comment Originated: 08/16/2017
08/16/2017:
Please indicate the "paint to match color" on plan set
Comment Number: 6 Comment Originated: 08/16/2017
Department: Stormwater Engineering
Contact: Dan Mogen, 970-224-6192, dmogen@fcgov.com
Topic: General
08/08/2017: I see in the plan notes that "the proposed facility will cause 'de minimis'
increase in stormwater runoff." It is also assumed that these improvements will
match existing grade and not inhibit existing drainage patterns.
The proposed site changes shown in this submittal are not substantial enough to
trigger Stormwater requirements; therefore, no requirements apply at this time. If
future submittals include site or grading changes that are not shown on these plans,
please contact Dan Mogen in Water Utilities Engineering at (970)224-6192 or
dmogen@fcgov.com to coordinate and determine what requirements, if any, will
apply.
Comment Number: 1 Comment Originated: 08/08/2017
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: General
08/22/2017: All plan sheets must be 24"x36".
Comment Number: 1 Comment Originated: 08/22/2017
08/22/2017: A legal description of the property where this equipment is located will
need to be added to sheet T1.
Comment Number: 2 Comment Originated: 08/22/2017
08/22/2017: There are line over text issues. See redlines.
Comment Number: 3 Comment Originated: 08/22/2017
Department: Zoning
Contact: Marcus Glasgow, 970-416-2338, mglasgow@fcgov.com
Topic: General
08/18/2017: Please provide landscape plan for proposed landscaping around new
facility.
Comment Number: 1 Comment Originated: 08/18/2017
Page 5 of 6
08/18/2017: Please provide photometric site plan with cut sheets of proposed light
fixtures. Light levels measured twenty (20) feet beyond the property line of the
development site (adjacent to residential uses or public rights-of-way) shall not
exceed one-tenth (0.1) foot-candle as a direct result of the on-site lighting. Light
sources shall be concealed and fully shielded and shall feature sharp cut-off
capability so as to minimize up-light, spill-light, glare and unnecessary diffusion on
adjacent property. Light fixtures shall be attached to poles and buildings by use of
nonadjustable angle brackets or other mounting hardware
Comment Number: 2 Comment Originated: 08/18/2017