Loading...
HomeMy WebLinkAboutFTC EASTSIDE PARK SC WTF VERIZON - PDP170029 - SUBMITTAL DOCUMENTS - ROUND 1 - REDLINED PLANS AND REPORTSFTC EASTSIDE PARK SC 1201 RIVERSIDE AVENUE FORT COLLINS, COLORADO 80524 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS FROM SOUTH VAUGHN WAY MERGE ONTO 1-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W, KEEP RIGHT AT THE FORK TO CONTINUE ON I-270W, TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FT. COLLINS. TAKE EXIT 268 FOR PROSPECT RD. TURN LEFT ONTO E PROSPECT RD. TURN RIGHT ONTO RIVERSIDE AVE. SITE WILL BE ON YOUR LEFT FORT COLLINS, COLORADO CLIENT PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 10740 NALL AVE. STE 400 OVERLAND PARK, KS 66211 CONTACT: JENNIFER THOMAS SCHNEIDER PHONE: 913-344-2030 VINEYARD CHURCH OF FORT COLLINS/THE DBA VINEYARD CHRISTIAN FELLOWSHIP FORT COLLINS, CO 80524 CONTACT: MARYANN TAYLOR PHONE: 970-484-5999 EXT206 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: Ram.Nandiraju@verizonwireless.com RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2012 (W/ LOCAL AMENDMENTS) NEC 2014 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: S S Y VP VP VP VP VP RD RD RD RD RDRD RD RD RD RD RD RD RD RD RD RD VP AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC RD AC V VP VP RD GM (E) 10' PUBLIC UTILITY EASEMENT (E) 6' PUBLIC UTILITY EASEMENT THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 Y 12'-0" 11'-0" 20'-0" 19'-0" 8'-0" 4'-0" 5'-6" 53'-2" GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 8. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET EIA/TIA-222-G AS PER IBC 2012 REQUIREMENTS. 14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-2 EQUIPMENT PLAN SCALE: 3/32"=1'-0" A SECTOR CABLE TABLE N/A AZIMUTH 55' LENGTH 2 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE PROPOSED FIBER RUN FROM VAULT TO NEW EQUIPMENT CABINET PROPOSED VERIZON EQUIPMENT CABINET MOUNTED ON H-FRAME 1/2" COAX N PROPOSED PCS RRH MOUNTED ON H-FRAME PROPOSED AWS RRH MOUNTED ON H-FRAME REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 4 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING STEVEN MARK MUSTARO JR, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52559 (EXP. 10/31/2017) EQUIPMENT PLAN Z-2 PROPOSED 2'x3' 3 FIBER VAULT PROPOSED VERIZON ANTENNA MOUNTED ON NEW POLE 2 Z-3 PROPOSED 10' WIDE ACCESS AND UTILITY EASEMENT PROPOSED 20'x12' VERIZON LEASE AREA PROPOSED ICE BRIDGE NEW COMMERCIAL POWER TO SITE PROPOSED CEDAR FENCE TO MATCH EXISTING PROPOSED 5' WIDE UTILITY EASEMENT Line Over Text 8/23/17 Z-1 SITE PLAN SCALE: 1"=40'-0" REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 4 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING STEVEN MARK MUSTARO JR, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52559 (EXP. 10/31/2017) SITE PLAN Z-1 2 (2) PROPOSED RRH'S AND EQUIPMENT CABINET EXISTING BUILDING (24'-5") PROPOSED FIBER RUN TO NEW EQUIPMENT CABINET PROPOSED 2'x3' FIBER VAULT LONG LAT SITE COORDINATES ƒ :(67 1$' ƒ 1257+ 1$' PROPOSED VERIZON ANTENNA ON NEW POLE PROPOSED VERIZON EQUIPMENT CABINET PROPOSED 10' WIDE ACCESS/UTILITY EASEMENT PROPOSED 12'-0" x 20'-0" VERIZON LEASE AREA EXISTING PROPERTY LINE EXISTING UNDERGROUND ELECTRICAL LINE EXISTING CURB EXISTING LANDSCAPING EXISTING PARKING LOT GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 06/01/17. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. PROPOSED 11'-0" x 19'-0" FENCE TO MATCH EXISTING LEGEND S T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX EV D STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GRAY-EXISTING PROPOSED 5' WIDE UTILITY EASEMENT Line Over Text 8/23/17 USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 EQUIPMENT PLAN Z-3 ELEVATIONS PROJECT DESCRIPTION 1. INSTALL NEW POLE WITHIN LEASE AREA 2. INSTALL NEW RADIO EQUIPMENT CABINET ON H-FRAMES IN LEASE AREA. 3. INSTALL (1) NEW ANTENNA ON NEW POLE 4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN ON STREET LEVEL. 5. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT. 6. INSTALL NEW COAX CABLES. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: RIVERSIDE COMMERCIAL PUD APN: 8718215901 PARCEL SIZE: N/A ELEVATION: 4959' (NAVD 88) STRUCTURE TYPE: NEW POLE STRUCTURE HEIGHT:  “ 7232)$17(11$ ANTENNA RAD CENTER:  “$*/ APPLICANT: VERIZON WIRELESS REAL ESTATE APPLICANT CONTACT: JENNIFER THOMAS SCHNEIDER 10740 NALL AVE. STE 400 OVERLAND PARK, KS 66211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 4 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING STEVEN MARK MUSTARO JR, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #52559 (EXP. 10/31/2017) Add a legal description for the property where this is located. 8/23/17 Plans must be 24"x36".