Loading...
HomeMy WebLinkAboutFTC EASTSIDE PARK SC WTF VERIZON - PDP170029 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC EASTSIDE PARK SC 1201 RIVERSIDE AVENUE FORT COLLINS, COLORADO 80524 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS FROM SOUTH VAUGHN WAY MERGE ONTO 1-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W, KEEP RIGHT AT THE FORK TO CONTINUE ON I-270W, TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FT. COLLINS. TAKE EXIT 268 FOR PROSPECT RD. TURN LEFT ONTO E PROSPECT RD. TURN RIGHT ONTO RIVERSIDE AVE. SITE WILL BE ON YOUR LEFT FORT COLLINS, COLORADO CLIENT PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 10740 NALL AVE. STE 400 OVERLAND PARK, KS 66211 CONTACT: JENNIFER THOMAS SCHNEIDER PHONE: 913-344-2030 VINEYARD CHURCH OF FORT COLLINS/THE DBA VINEYARD CHRISTIAN FELLOWSHIP FORT COLLINS, CO 80524 CONTACT: MARYANN TAYLOR PHONE: 970-484-5999 EXT206 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING PHOTOSIMULATION VIEWS PH-1 2 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING EAST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST) N.T.S. REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING PHOTOSIMULATION VIEWS PH-1 3 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING WEST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING WEST) N.T.S. 4'-10" 32'-0" 2'-2" 2'-2" REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING LINE DRAWING LD-1 4 1 LD-1 METRO CELL LINE DRAWING N.T.S. ALL ASSOCIATED SERVICE EQUIPMENT WITHIN POLE BASE PROPOSED QUASI OMNI ANTENNA MOUNTED TO POLE S S Y VP VP VP VP VP RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD VP AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC RD AC V VP VP RD GM (E) 10' PUBLIC UTILITY EASEMENT (E) 6' PUBLIC UTILITY EASEMENT 53'-2" SETBACK THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Y 12'-0" 20'-0" 53'-2" 16'-1" 10'-0" 5'-0" 5'-0" GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 8. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. 24'-5" 6'-0" 35'-0" 33'-4" 30'-9" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. GRADE 0'-0" AGL TOP OF FENCE 6'-0" AGL 1 Z-3 EXISTING WEST ELEVATION SCALE: 1/16"=1'-0" REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS Z-3 7 S S S Y WV WV WV WV WV W W W UE UE UE TV TV TV TV TV SS SS SS SS SS TV TV V P VP VP VP VP RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD VP AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC RD AC V S S S S S S Y VP VP VP VP VP RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD VP AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC RD AC V VP VP RD GM 20'-0" PROPERTY LINE OFFSET THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. S S S S S S Y VP VP VP VP VP RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD VP AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC RD AC V VP VP RD GM 20'-0" PROPERTY LINE OFFSET THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 PM-2 PHOTOMETRIC PLAN SCALE: 1"=40'-0" RIVENDALE DR 1 inch = 40ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING PHOTOMETRIC PLAN - PROPOSED PM-2 10 RIVERSIDE AVE EXISTING BUILDING (24'-5") INSTALL NEW ALL-IN-ONE SMALL CELL POLE EXISTING PROPERTY LINE EXISTING CURB EXISTING LANDSCAPING Know what's below. Call before you dig. N 1 PM-1 PHOTOMETRIC PLAN SCALE: 1"=40'-0" RIVENDALE DR 1 inch = 40ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING PHOTOMETRIC PLAN - EXISTING CONDITIONS PM-1 9 RIVERSIDE AVE EXISTING BUILDING (24'-5") EXISTING PROPERTY LINE EXISTING CURB EXISTING LANDSCAPING VP VP E E E E E E E E RD GM GAS W SS S S S Y WV WV WV WV WV W W W UE UE UE TV TV TV TV TV SS SS SS SS SS TV TV V P VP VP VP VP RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD VP AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC RD AC V VP VP E E E E E E E E RD GM GAS W SS REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING LANDSCAPE PLAN LS-1 8 1 LS-1 LANDSCAPE PLAN (BEFORE) SCALE: 1/64"=1'-0" 32 0 16 32 64 128 1/64 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED 12'x20' LEASE AREA 2 LS-1 LANDSCAPE PLAN (AFTER) SCALE: 1/64"=1'-0" 32 0 16 32 64 128 1/64 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) TOP OF BUILDING 24'-5" AGL EXISTING FENCE EXISTING BUILDING GRADE 0'-0" AGL PROPOSED VERIZON RAD CENTER 33'-4" AGL PROPOSED QUASI OMNI ANTENNA MOUNTED TO POLE TOP OF PROPOSED POLE 35'-0" AGL NEW ALL-IN-ONE SMALL CELL POLE (PAINTED ROMAN COFFEE COLOR) 2 Z-3 PROPOSED WEST ELEVATION SCALE: 1/16"=1'-0" EXISTING STONE WALL EXISTING FENCE EXISTING STONE WALL EXISTING BUILDING PROPOSED SLENDERFORM 48 LED, 240V LIGHTING (TYP OF 2) NOTE: PROPOSED LIGHTING TO CONFORM TO SECTION 3.2.4 OF THE FORT COLLINS LAND USE CODE TOP OF PROPOSED LIGHT 30'-9" AGL PROPOSED FUTURE CO-LOCATION Know what's below. Call before you dig. 1 Z-2 EQUIPMENT PLAN SCALE: 3/32"=1'-0" A SECTOR CABLE TABLE N/A AZIMUTH 45' LENGTH 2 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 1/2" COAX N REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EQUIPMENT PLAN Z-2 PROPOSED 2'x3' 6 FIBER VAULT INSTALL NEW ALL-IN-ONE SMALL CELL POLE 2 Z-3 PROPOSED 10' WIDE ACCESS AND UTILITY EASEMENT PROPOSED 20'x12' VERIZON LEASE AREA PROPOSED POWER TO BE PULLED FROM EXISTING TRANSFORMER PROPOSED FUTURE CO-LOCATION PROPOSED 5' WIDE UTILITY EASEMENT PROPOSED FIBER RUN FROM VAULT TO NEW EQUIPMENT CABINET PROPOSED QUASI OMNI ANTENNA MOUNTED TO POLE PROPOSED 5'-0" UTILITY EASEMENT PROPOSED 6"Ø CONCRETE BOLLADS (TYP OF 4) Call before you dig. N 1 Z-1 SITE PLAN SCALE: 1"=40'-0" RIVENDALE DR 1 inch = 40ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING SITE PLAN Z-1 5 RIVERSIDE AVE EXISTING BUILDING (24'-5") PROPOSED FIBER RUN TO EQUIPMENT PROPOSED 2'x3' FIBER VAULT LONG LAT SITE COORDINATES 105° 03' 21.26" WEST (NAD 83) 40° 34' 33.29" NORTH (NAD83) INSTALL NEW ALL-IN-ONE SMALL CELL POLE PROPOSED 10' WIDE ACCESS/UTILITY EASEMENT PROPOSED 12'-0" x 20'-0" VERIZON LEASE AREA EXISTING PROPERTY LINE EXISTING UNDERGROUND ELECTRICAL LINE EXISTING CURB EXISTING LANDSCAPING EXISTING PARKING LOT GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 06/01/17. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. LEGEND S T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX EV D STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GRAY-EXISTING PROPOSED 5' WIDE UTILITY EASEMENT PROPOSED FUTURE CO-LOCATION PROPOSED 5'-0" UTILITY EASEMENT USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 EQUIPMENT PLAN Z-3 ELEVATIONS PROJECT DESCRIPTION 1. INSTALL NEW ALL-IN-ONE SMALL CELL POLE WITH LIGHTS TO MATCH EXISTING. 2. INSTALL (2) NEW REMOTE RADIO HEADS WITHIN NEW POLE. 3. INSTALL NEW FIBER VAULT NEAR PROPERTY LINE. 4. RUN FIBER TO PROPOSED EQUIPMENT. 5. INSTALL ASSOCIATED SERVICE EQUIPMENT WITHIN NEW POLE. 6. INSTALL NEW POWER TO PROPOSED EQUIPMENT. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FORT COLLINS ZONING: EMPLOYMENT DISTRICT APN: 8718215901 PARCEL SIZE: N/A ELEVATION: 4959' (NAVD 88) STRUCTURE TYPE: NEW POLE STRUCTURE HEIGHT: 35'-0"± (TOP OF ANTENNA) ANTENNA RAD CENTER: 33'-4"± AGL APPLICANT: VERIZON WIRELESS REAL ESTATE APPLICANT CONTACT: JENNIFER THOMAS SCHNEIDER 10740 NALL AVE. STE 400 OVERLAND PARK, KS 66211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 10 SITE NAME: FTC EASTSIDE PARK SC SITE ADDRESS: 1201 RIVERSIDE AVE FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT #: 097-17-0103 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 05-08-17 KRC ZONING B 06-06-17 MFF FINAL ZONING C 07-06-17 GAC REVISED FINAL ZONING D 08-08-17 KRC REVISED FINAL ZONING SHEET NUMBER: E 10-16-17 GAC REVISED FINAL ZONING F 11-3-17 LCW REVISED FINAL ZONING LEGAL DESCRIPTION A PORTION OF LOT 1 AND THAT PART OF TRACT "A' OF RIVERSIDE COMMERCIAL PLANNED UNIT DEVELOPMENT, FIRST FILING, AND REPLAT OF LOT 2 OF RIVERSIDE SUBDIVISION, FOURTH FILING, ACCORDING TO THE RECORDED PLAT THEREOF, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. PH-1 PHOTOSIMULATION VIEWS LS-1 LANDSCAPE PLAN PM-1 PHOTOMETRIC PLAN - EXISTING CONDITIONS PM-2 PHOTOMETRIC PLAN - PROPOSED PH-2 PHOTOSIMULATION VIEWS LD-1 LINE DRAWING