HomeMy WebLinkAboutFTC EASTSIDE PARK SC WTF VERIZON - PDP170029 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC EASTSIDE PARK SC
1201 RIVERSIDE AVENUE
FORT COLLINS, COLORADO 80524
SMALL CELL
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
FROM SOUTH VAUGHN WAY MERGE ONTO 1-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W, KEEP
RIGHT AT THE FORK TO CONTINUE ON I-270W, TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FT.
COLLINS. TAKE EXIT 268 FOR PROSPECT RD. TURN LEFT ONTO E PROSPECT RD. TURN RIGHT
ONTO RIVERSIDE AVE. SITE WILL BE ON YOUR LEFT
FORT COLLINS, COLORADO
CLIENT
PROPERTY OWNER
VERIZON WIRELESS REAL ESTATE
10740 NALL AVE. STE 400
OVERLAND PARK, KS 66211
CONTACT: JENNIFER THOMAS SCHNEIDER
PHONE: 913-344-2030
VINEYARD CHURCH OF FORT COLLINS/THE DBA
VINEYARD CHRISTIAN FELLOWSHIP
FORT COLLINS, CO 80524
CONTACT: MARYANN TAYLOR
PHONE: 970-484-5999 EXT206
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JASON SHELLEDY
PHONE: 970-646-1283
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
1196 GRANT ST. UNIT 313
DENVER, CO 80203
CONTACT: RYAN SAGAR
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2015 (W/ LOCAL AMENDMENTS)
NEC 2017
NFPA-1 (2006)
U - UTILITY
IIB
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
PHOTOSIMULATION
VIEWS
PH-1
2
2
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING EAST)
N.T.S.
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST)
N.T.S.
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
PHOTOSIMULATION
VIEWS
PH-1
3
2
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING WEST)
N.T.S.
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING WEST)
N.T.S.
4'-10"
32'-0"
2'-2"
2'-2"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
LINE DRAWING
LD-1
4
1
LD-1
METRO CELL LINE DRAWING
N.T.S.
ALL ASSOCIATED SERVICE
EQUIPMENT WITHIN POLE BASE
PROPOSED QUASI
OMNI ANTENNA
MOUNTED TO POLE
S
S
Y
VP
VP
VP
VP
VP
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
VP
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
RD
AC
V
VP
VP
RD
GM
(E) 10' PUBLIC UTILITY EASEMENT
(E) 6' PUBLIC UTILITY EASEMENT
53'-2"
SETBACK
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Y
12'-0"
20'-0"
53'-2"
16'-1"
10'-0"
5'-0"
5'-0"
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES
ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES,
UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY
FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES.
3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN
WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO
THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR
OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT
RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE
OVERALL INTENT OF THESE DRAWINGS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL
EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING
CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE
CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY.
5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE
PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO
COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO
SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE
CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS"
INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE
STRUCTURES ARE PROPOSED.
8. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION
(THERE IS NO HANDICAP ACCESS REQUIRED).
10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE
WATER OR SANITARY SERVICE.
11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE
METER.
12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH
WITH RF ENGINEERING PRIOR TO INSTALLATION.
13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER
IBC 2015 REQUIREMENTS.
14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED
STEEL.
15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL
UTILITIES PRIOR TO EXCAVATING.
16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST
LOCATE IT AND CONTACT OWNERS REPRESENTATIVE.
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
24'-5"
6'-0"
35'-0"
33'-4"
30'-9"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
GRADE
0'-0" AGL
TOP OF FENCE
6'-0" AGL
1
Z-3
EXISTING WEST ELEVATION
SCALE: 1/16"=1'-0"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ELEVATIONS
Z-3
7
S
S
S
Y
WV
WV
WV
WV
WV
W W W
UE
UE
UE
TV
TV TV
TV TV
SS SS
SS SS SS
TV TV
V
P
VP
VP
VP
VP
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
VP
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
RD
AC
V
S
S
S
S
S
S
Y
VP
VP
VP
VP
VP
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
VP
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
RD
AC
V
VP
VP
RD
GM
20'-0" PROPERTY LINE OFFSET
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
S
S
S
S
S
S
Y
VP
VP
VP
VP
VP
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
VP
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
RD
AC
V
VP
VP
RD
GM
20'-0" PROPERTY LINE OFFSET
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
1
PM-2
PHOTOMETRIC PLAN
SCALE: 1"=40'-0"
RIVENDALE DR
1 inch = 40ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
PHOTOMETRIC PLAN -
PROPOSED
PM-2
10
RIVERSIDE AVE
EXISTING
BUILDING
(24'-5")
INSTALL NEW ALL-IN-ONE SMALL
CELL POLE
EXISTING
PROPERTY LINE
EXISTING
CURB
EXISTING
LANDSCAPING
Know what's below.
Call before you dig.
N
1
PM-1
PHOTOMETRIC PLAN
SCALE: 1"=40'-0"
RIVENDALE DR
1 inch = 40ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
PHOTOMETRIC PLAN -
EXISTING CONDITIONS
PM-1
9
RIVERSIDE AVE
EXISTING
BUILDING
(24'-5")
EXISTING
PROPERTY LINE
EXISTING
CURB
EXISTING
LANDSCAPING
VP
VP
E
E
E
E
E
E
E E
RD
GM
GAS
W
SS
S
S
S
Y
WV
WV
WV
WV
WV
W W W
UE
UE
UE
TV
TV TV
TV TV
SS SS
SS SS SS
TV TV
V
P
VP
VP
VP
VP
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
VP
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
RD
AC
V
VP
VP
E
E
E
E E
E
E E
RD
GM
GAS
W
SS
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
LANDSCAPE
PLAN
LS-1
8
1
LS-1
LANDSCAPE PLAN (BEFORE)
SCALE: 1/64"=1'-0"
32 0 16 32 64 128
1/64 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROPOSED 12'x20'
LEASE AREA
2
LS-1
LANDSCAPE PLAN (AFTER)
SCALE: 1/64"=1'-0"
32 0 16 32 64 128
1/64 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
TOP OF BUILDING
24'-5" AGL
EXISTING
FENCE
EXISTING
BUILDING
GRADE
0'-0" AGL
PROPOSED VERIZON RAD CENTER
33'-4" AGL
PROPOSED QUASI OMNI ANTENNA
MOUNTED TO POLE
TOP OF PROPOSED POLE
35'-0" AGL
NEW ALL-IN-ONE
SMALL CELL POLE
(PAINTED ROMAN
COFFEE COLOR)
2
Z-3
PROPOSED WEST ELEVATION
SCALE: 1/16"=1'-0"
EXISTING STONE
WALL
EXISTING
FENCE
EXISTING STONE
WALL
EXISTING
BUILDING
PROPOSED SLENDERFORM 48
LED, 240V LIGHTING (TYP OF 2)
NOTE:
PROPOSED LIGHTING TO CONFORM TO
SECTION 3.2.4 OF THE FORT COLLINS
LAND USE CODE
TOP OF PROPOSED LIGHT
30'-9" AGL
PROPOSED FUTURE
CO-LOCATION
Know what's below.
Call before you dig.
1
Z-2
EQUIPMENT PLAN
SCALE: 3/32"=1'-0"
A
SECTOR
CABLE TABLE
N/A
AZIMUTH
45'
LENGTH
2
NO. TYPE
NOTES:
1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL
FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING.
2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE.
3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED
HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS.
SIZE
1/2" COAX
N
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
3/32 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
EQUIPMENT PLAN
Z-2
PROPOSED 2'x3' 6
FIBER VAULT
INSTALL NEW ALL-IN-ONE
SMALL CELL POLE
2
Z-3
PROPOSED 10' WIDE ACCESS
AND UTILITY EASEMENT
PROPOSED 20'x12'
VERIZON LEASE AREA
PROPOSED POWER TO BE PULLED
FROM EXISTING TRANSFORMER
PROPOSED FUTURE
CO-LOCATION
PROPOSED 5' WIDE
UTILITY EASEMENT
PROPOSED FIBER RUN FROM VAULT
TO NEW EQUIPMENT CABINET
PROPOSED QUASI
OMNI ANTENNA
MOUNTED TO POLE
PROPOSED 5'-0" UTILITY
EASEMENT
PROPOSED 6"Ø CONCRETE
BOLLADS (TYP OF 4)
Call before you dig.
N
1
Z-1
SITE PLAN
SCALE: 1"=40'-0"
RIVENDALE DR
1 inch = 40ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
SITE PLAN
Z-1
5
RIVERSIDE AVE
EXISTING
BUILDING
(24'-5")
PROPOSED FIBER RUN TO
EQUIPMENT
PROPOSED 2'x3'
FIBER VAULT
LONG
LAT
SITE COORDINATES
105° 03' 21.26" WEST (NAD 83)
40° 34' 33.29" NORTH (NAD83)
INSTALL NEW ALL-IN-ONE SMALL
CELL POLE
PROPOSED 10' WIDE
ACCESS/UTILITY EASEMENT
PROPOSED 12'-0" x 20'-0"
VERIZON LEASE AREA
EXISTING
PROPERTY LINE
EXISTING
UNDERGROUND
ELECTRICAL LINE
EXISTING
CURB
EXISTING
LANDSCAPING
EXISTING
PARKING
LOT
GENERAL NOTES:
1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY
DETAIL" BY RLF CONSULTING, DATED 06/01/17.
2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF.
THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED.
3. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP
ACCESS REQUIRED).
5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY
SERVICE.
6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988).
7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE.
8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID
WASTE RECEPTACLES.
LEGEND
S
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
EV
D
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GRAY-EXISTING
PROPOSED 5' WIDE
UTILITY EASEMENT
PROPOSED FUTURE
CO-LOCATION
PROPOSED 5'-0" UTILITY EASEMENT
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 EQUIPMENT PLAN
Z-3 ELEVATIONS
PROJECT DESCRIPTION
1. INSTALL NEW ALL-IN-ONE SMALL CELL POLE WITH LIGHTS TO MATCH EXISTING.
2. INSTALL (2) NEW REMOTE RADIO HEADS WITHIN NEW POLE.
3. INSTALL NEW FIBER VAULT NEAR PROPERTY LINE.
4. RUN FIBER TO PROPOSED EQUIPMENT.
5. INSTALL ASSOCIATED SERVICE EQUIPMENT WITHIN NEW POLE.
6. INSTALL NEW POWER TO PROPOSED EQUIPMENT.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
JURISDICTION: CITY OF FORT COLLINS
ZONING: EMPLOYMENT DISTRICT
APN: 8718215901
PARCEL SIZE: N/A
ELEVATION: 4959' (NAVD 88)
STRUCTURE TYPE: NEW POLE
STRUCTURE HEIGHT: 35'-0"± (TOP OF ANTENNA)
ANTENNA RAD CENTER: 33'-4"± AGL
APPLICANT: VERIZON WIRELESS REAL ESTATE
APPLICANT CONTACT: JENNIFER THOMAS SCHNEIDER
10740 NALL AVE. STE 400
OVERLAND PARK, KS 66211
PH: 913-344-2030
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: 720 279-8973
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 10
SITE NAME:
FTC EASTSIDE PARK SC
SITE ADDRESS:
1201 RIVERSIDE AVE
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT #: 097-17-0103
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 05-08-17 KRC ZONING
B 06-06-17 MFF FINAL ZONING
C 07-06-17 GAC REVISED FINAL ZONING
D 08-08-17 KRC REVISED FINAL ZONING
SHEET NUMBER:
E 10-16-17 GAC REVISED FINAL ZONING
F 11-3-17 LCW REVISED FINAL ZONING
LEGAL DESCRIPTION
A PORTION OF LOT 1 AND THAT PART OF TRACT "A' OF RIVERSIDE COMMERCIAL PLANNED UNIT
DEVELOPMENT, FIRST FILING, AND REPLAT OF LOT 2 OF RIVERSIDE SUBDIVISION, FOURTH FILING,
ACCORDING TO THE RECORDED PLAT THEREOF, CITY OF FORT COLLINS, COUNTY OF LARIMER,
STATE OF COLORADO.
PH-1 PHOTOSIMULATION VIEWS
LS-1 LANDSCAPE PLAN
PM-1 PHOTOMETRIC PLAN - EXISTING CONDITIONS
PM-2 PHOTOMETRIC PLAN - PROPOSED
PH-2 PHOTOSIMULATION VIEWS
LD-1 LINE DRAWING