HomeMy WebLinkAboutTHE HUB ON CAMPUS - PDP - PDP160038 - SUBMITTAL DOCUMENTS - ROUND 4 - SUPPORTING DOCUMENTATIONDRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Sam Coutts Layout: 15 SHADOW ANALYSIS Printed On: 11/7/2017 3:49 PM File Name: 9 BUILDING ELEVATIONS.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
Sam Coutts
419 Canyon Ave., Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
CORE CAMPUS INVESTMENTS PARTNERS LLC.
Chad Matesi / Mark Goehausen
2234 W. North Avenue
Chicago, IL 60647
p. 773.969.5741
ENGINEER
ARCHITECT
APPLICANT / LAND PLANNER
KIMLEY-HORN
Lesley Netzer
1001 Warrenville Road, Suite 350
Lisle, IL 60532
p. 630-487-5555
WARE MALCOMB
Grant Brandenburg
1900 Spring Road, Suite 210
Oak Brook, IL 60523
p. 630-570-6765
DEVELOPER
SHADOW ANALYSIS
PROJECT
DEVELOPMENT PLAN
HUB ON CAMPUS FORT
COLLINS
02 PDP 2 02/22/17
01 PDP 11/30/16
FORT COLLINS, CO
SC
R16-046
15 OF 19
NORTH
Shadow Study Summary
LUC 3.2.3(E)(1) Shading
The Land Use Code requires to the “maximum extent feasible” that structures on the property not cast a shadow greater than a 25 foot hypothetical wall along property lines would cast
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Sam Coutts Layout: 16 SHADOW ANALYSIS Printed On: 11/7/2017 3:49 PM File Name: 9 BUILDING ELEVATIONS.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
Sam Coutts
419 Canyon Ave., Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
CORE CAMPUS INVESTMENTS PARTNERS LLC.
Chad Matesi / Mark Goehausen
2234 W. North Avenue
Chicago, IL 60647
p. 773.969.5741
ENGINEER
ARCHITECT
APPLICANT / LAND PLANNER
KIMLEY-HORN
Lesley Netzer
1001 Warrenville Road, Suite 350
Lisle, IL 60532
p. 630-487-5555
WARE MALCOMB
Grant Brandenburg
1900 Spring Road, Suite 210
Oak Brook, IL 60523
p. 630-570-6765
DEVELOPER
SHADOW ANALYSIS
PROJECT
DEVELOPMENT PLAN
HUB ON CAMPUS FORT
COLLINS
02 PDP 2 02/22/17
01 PDP 11/30/16
FORT COLLINS, CO
SC
R16-046
16 OF 19
NORTH
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Sam Coutts Layout: 17 SHADOW ANALYSIS Printed On: 11/7/2017 3:49 PM File Name: 9 BUILDING ELEVATIONS.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
Sam Coutts
419 Canyon Ave., Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
CORE CAMPUS INVESTMENTS PARTNERS LLC.
Chad Matesi / Mark Goehausen
2234 W. North Avenue
Chicago, IL 60647
p. 773.969.5741
ENGINEER
ARCHITECT
APPLICANT / LAND PLANNER
KIMLEY-HORN
Lesley Netzer
1001 Warrenville Road, Suite 350
Lisle, IL 60532
p. 630-487-5555
WARE MALCOMB
Grant Brandenburg
1900 Spring Road, Suite 210
Oak Brook, IL 60523
p. 630-570-6765
DEVELOPER
SHADOW ANALYSIS
PROJECT
DEVELOPMENT PLAN
HUB ON CAMPUS FORT
COLLINS
02 PDP 2 02/22/17
01 PDP 11/30/16
FORT COLLINS, CO
SC
R16-046
17 OF 19
NORTH
SHADOW STUDY SUMMARY
LUC 3.5.1(G) Building Height Review
In regards to building height review, this standard applies to all buildings over forty feet tall. Since the main mixed use building on this site measures 75 feet in height, but the
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Sam Coutts Layout: 18 SHADOW ANALYSIS Printed On: 11/7/2017 3:49 PM File Name: 9 BUILDING ELEVATIONS.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
Sam Coutts
419 Canyon Ave., Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
CORE CAMPUS INVESTMENTS PARTNERS LLC.
Chad Matesi / Mark Goehausen
2234 W. North Avenue
Chicago, IL 60647
p. 773.969.5741
ENGINEER
ARCHITECT
APPLICANT / LAND PLANNER
KIMLEY-HORN
Lesley Netzer
1001 Warrenville Road, Suite 350
Lisle, IL 60532
p. 630-487-5555
WARE MALCOMB
Grant Brandenburg
1900 Spring Road, Suite 210
Oak Brook, IL 60523
p. 630-570-6765
DEVELOPER
SHADOW ANALYSIS
PROJECT
DEVELOPMENT PLAN
HUB ON CAMPUS FORT
COLLINS
02 PDP 2 02/22/17
01 PDP 11/30/16
FORT COLLINS, CO
SC
R16-046
18 OF 19
NORTH
multifamily measures 39' in height, this standard only applies to the main mixed use building. The shadow study shown on sheets x and
x show shadows cast by the main building (blue shadow) during the three months of the year that have the greatest potential for shadowing.
The following diagrams show that this project complies with LUC 3.5.1(G) for the following reasons:
1. The building casts a shadow on the property to the west during the morning, but it is completely out of the shadow by noon. The building casts a shadow on the property to the east
during the afternoon, but it is unaffected before noon.
2. The adjacent buildings are shaded only part of the day, which is not sufficient to preclude their use of solar energy technology.
3. The proposed building utilizes non-glare window materials.
4.The site lighting is designed so as to prevent intrusion to adjacent properties. This is achieved through pole height and downward direction cutoffs. The lighting plan meets all codes
relating to light spilling over property lines.
5.Although the property to the west has a parking lot that is shaded in the morning, the applicant has offered to mitigate accumulation of ice and snow through a maintenance agreement.
These talks will further as the development process continues.
6. The proposed building provides privacy to its tenants, as well as adjacent properties, through the use of landscaping, pedestrian areas and building orientation.
a. The residential building to the east is oriented in a way that the back of the units face this project with an existing fence on the property line. Beyond that fence is a proposed
raingarden and pedestrian area that provide privacy and a sense of place to this development.
b. The commercial building to the west, and its parking lot, is screened by a large landscape area to give residents of this development privacy from car headlights and commercial patrons.
7. The proposed buildings step back in height from the arterial right-of-way. The five story mixed use building steps down to a 4our story attached parking structure to the three story
multifamily building along the south of the property line. The multifamily buildings that neighbor this project to the south are
three stories. This stepping creates a massing that is compatible with the adjacent neighborhood.
on buildings on adjacent properties. This
requirement applies only to the proposed parking structure located within the MMN district along the southwestern property boundary. The main building along Elizabeth is specifically
exempt from the shading provision as it is within
the Community Commercial District.
The shadow study shows the shadows created by the proposed multifamily building as it would be on December 21st. The study shows the shadows created by the parking structure (blue) and
the shadow cast by a 25' wall at the
property line of the project (red). The proposed building will create a shadow greater than the 25' hypothetical wall, however, the shadow from the proposed building does not cast a
shadow onto any adjacent buildings. Therefore,
the project meets the shading requirements of the LUC 3.2.3(E)(1).