HomeMy WebLinkAbout4406 SENECA ST. GROUP HOME - PDP - PDP170024 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS (13)REMODEL FOR
LOT 14, BLOCK TWO - REGENCY PARK P.U.D.
FORT COLLINS, COLORADO
PROJECT:
P.O. BOX 2066 FORT COLLINS, CO. 80522 970-472-5667
P.O. BOX 2066 FORT COLLINS, CO. 80522 970-472-5667
ISSUE DATE:
REVISION:
5/25/17
4
4406 SENECA
A1.0 - SITE PLAN
A2.0 - EXISTING BASEMENT DEMO PLAN
A2.2 - EXISTING MAIN FLOOR DEMO PLAN
A2.3 - NEW MAIN FLOOR PLAN
A2.1 - NEW BASEMENT PLAN
INDEX OF DRAWINGS:
A. ALL WINDOWS TO BE MIN. (.35 U-FACTOR) U.N.O.
A. ALL EXTERIOR WALLS ARE 2X6 STUDS 2'-0" O.C. U.N.O.
B. ALL MAIN FLOOR WALLS ARE 9'-1
1
8" HIGH ON MAIN FLOOR U.N.O.
C. ALL ANGLED WALLS ON FLOOR PLANS ARE AT 45 DEGREE ANGLE, U.N.O.
D. ALL EXTERIOR HEADERS TO BE (2) 2x10 W/ 1-2x6 TRIMMER EA. END U.N.O.
E. ALL WINDOW HEADER HEIGHTS TO BE 7'-0" FROM A.F.F. U.N.O.
A. PROVIDE TEVEK HOUSE WRAP AS PER PENETRATION DETAILS, WRAP OVER TOP PLATE 12" TOWARD
INSIDE OF HOUSE PRIOR TO INSTALLING TRUSSES. SHEETROCK INSTALLERS SHALL STAPLE 12" OVERAGE
C. ALL OUTLETS AND SWITCHES TO BE INSTALLED PER LOCAL AND GOVERNMENTAL
CODES
D. VERIFY CABINET LAYOUTS WITH NOTES ON FLOOR OR WITH SUPER.
E. VERIFY DOOR SWINGS WITH NOTES ON JAMBS OR WITH SUPER.
GENERAL NOTES:
NOTE: ( REFER TO INDIVIDUAL SHEETS FOR ALL REVISIONS.)
A. ALL DIMENSIONS SHALL BE FIELD VERIFIED AND ARE THE SOLE RESPONSIBLITY OF
EACH TRADE TO VERIFY PRIOR TO CONSTRUCTION. ANY DISCREPENCIES SHOULD BE
REPORTED TO THE BUIDLING SUPERITENDENT BEFORE PROCEDING.
A. ALL CONSTRUCTION SHALL MEET ALL LOCAL, STATE AND FEDERAL CODES AND REQUIREMENTS.
ANY WORK COMPLETED NOT MEETING CODE SHALL BE CORRECTED AND THE COST FOR SUCH
REPAIRS SHALL BE THE RESPONSIBILITY OF THE SUB CONTRACTOR WHOM HAS CAUSED THE
VIOLATION.
F. FRAMER SHALL PROVIDE AND INSTALL 2X6 BLOCKING IN WALLS EXCEPTING MILLWOK
/ CABINETS @ 34" O.C. HORIZ. / 56" O.C. HORIZ. / 86" O.C. HORIZ. - TYP. ALL LOCATIONS.A.F.F.
GENERAL REQUIREMENTS:
B. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, INSTALLED,
ERECTED, USED, CLEANED AND CONDITIONED IN STRICT ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS.
C. ALL CONTRACTORS, SUBCONTRACTORS,SUPPLIERS AND FABRICATORS SHALL BE RESPONSIBLE FOR THE
CONTENT OF DRAWINGS AND SPECIFICATIONS AND FOR THE SUPPLY AND DESIGN OF APPROPRIATE
MATERIALS AND WORK PERFORMANCE.
CODES:
B. DRAWINGS WERE PREPARED TO COMPLY WITH THE FOLLOWING CODES:.
1. 2015 INTERNATIONAL BUILDING CODE (IBC)
A. PROVIDE SITE PREPARATION AS SPECIFIED BY SOILS ENGINEER AND / OR STRUCTURAL ENGINEER.
SITEWORK:
B. PROVIDE CONSISTANT COMPACTION OF THE TOP 8" OF SUBGRADE AND ALL FILL AND BACKFILL MATERIAL
BENEATH STRUCTURE, WALKS AND PAVEMENTS TO MEET THE STATED SOIL PRESSURE.
C. PROVIDE FOUNDATION DRAINAGE AS SPECIFIED BY SOIL ENGINEER.
D. PROVIDE TEMPOPARY EROSION CONTROL AS PER LOCAL, STATE AND FEDERAL CODES..
A. SEE STRUCTURAL DRAWINGS FOR ALL CONCRETE REQUIREMENTS.
CONCRETE:
4406 SENECA STREET
1
:
104.68'
1
(
100.00'
1
:
109.76'
LOT 14
5'-0"
B.S.
5'-0"
B.S.
10'-0"
EASEMENT.
STAIRS
DN
CONCRETE
EXISTING HOUSE
EXISTING
DRIVE
8'-6"
5'-8"
16'-0"
4'-0"
NEW CONCRETE
NEW CONCRETE
STAIRWELL. REFER
TO PLANS.
PROPERTY
LINE.-TYP.
SETBACK
LINE.-TYP.
NEW STEPPED
TIMBER WINDOW
WELL. ADJUST
LANDSCAPING AS
NEEDED.
S
SITE PLAN
LOT 14, BLOCK TWO
SCALE: 1" = 10'-0"
NEW WHOLE
HOUSE EMERGENCY
GENERATOR.
SIDEWALK.
EXISTING FENCE
EXISTING SHED.
EXISTING
ELECTRICAL
PIT.
EXISTING A/C
CONDENSER
TO REMAIN.
EXISTING A/C
CONDENSER
TO RELOCATED.
VERIFY
SHOWER
CLOSET
BEDROOM 5
CARPET
SHOWER
TUB
STAIRS
UP
CARPET
MECHANICAL
BATH
TILE
STORAGE
REMOVE WALL AS
NEEDED FOR NEW
DOOR.
REMOVE WALL AS
NEEDED FOR NEW
DOOR.
REMOVE WALLS AS
NEEDED FOR NEW
DOOR. - TYP.
REMOVE EXISTING
DOORS.
REMOVE WALLS AS
NEEDED FOR NEW
DOOR. - TYP.
REMOVE EXISTING
DOORS.
OPEN AREA
CARPET
OPEN AREA
CARPET
OPEN AREA
CARPET
OPEN AREA
CARPET
CAREGIVER
KITCHENETTE
TILE
CAREGIVER
BEDROOM
CARPET
CAREGIVER
FAMILYROOM
CARPET
CAREGIVER
NOOK
CARPET
CAREGIVER
W.I.C.
CARPET
CAREGIVER
BATH
TILE
CLOSET
REMOVE EARTH AS
NEEDED FOR NEW
EXTERIOR STAIRWAY.
REMOVE CONCRETE AS
SHOWER
SHOWER
TUB
STAIRS
UP
CARPET
CAREGIVER
KITCHENETTE
TILE
CAREGIVER
MECHANICAL
CLOSET
RESIDENT ROOM
#8
CARPET
BATH
TILE
CLOSET
ENTRY
WOOD
HALLWAY
WOOD
GATHERING ROOM
CARPET
STAIRS
UP
CONCRETE
4'-1"
4'-1"
5'-3"
9'-61
4"
13'-4
3
4"
2/10X6/8
1R1S
36V
1R1S
5S
2/10X6/8
2/10X6/8
RESIDENT ROOM
#7
CARPET
OFFICE
CARPET
CAREGIVER
BEDROOM
CARPET
CAREGIVER
FAMILYROOM
CARPET
CAREGIVER
NOOK
CARPET
CAREGIVER
W.I.C.
CARPET
CAREGIVER
DRYER
WASH.
2 - CAR GARAGE
CONCRETE
LAUNDRY
WOOD PWDR.
WOOD
FAMILY ROOM
WOOD
KITCHEN
WOOD
DBL. DESK
OVEN
ISLAND
D.W
COOKTOP
GATHERING ROOM
WOOD
STAIRS
DN.
CARPET
SPA POOL
CLOSET
CLOSET
BEDROOM 4
WOOD
CLOSET
BEDROOM 2
WOOD
CLOSET
CLOSET
TUB/SHOWER
BEDROOM 3
WOOD
BATH
TILE
COVERED PORCH
CONCRETE
HALLWAY
WOOD
W.I.C.
WOOD
MASTER
BEDROOM
WOOD
6' SOAKER TUB
CLOSET
SHOWER
MASTER BATH
TILE
REMOVE EXISTING MAN DOOR.
REMOVE EXISTING
GARAGE DOOR. - TYP.
REMOVE EXISTING
STEPS.
REMOVE EXISTING
WALL CABINETS. - TYP.
REMOVE EXISTING
DOORS.
REMOVE WALL AS
DRYER
WASH.
LAUNDRY
WOOD PWDR.
WOOD
FAMILY ROOM
WOOD
KITCHEN
WOOD
ISLAND
D.W
COOKTOP
GATHERING ROOM
WOOD
STAIRS
DN.
CARPET
SPA POOL
CLOSET
CLOSET
CLOSET
CLOSET
BATH
TILE
COVERED PORCH
CONCRETE
HALLWAY
WOOD
CLOSET
HALLWAY
WOOD
OFFICE
WOOD
STAIRS
DN
CONCRETE
CLOSET
LINEN
BATH
TILE
SHOWER
60"
30"
PANTRY
DBL.
OVEN
54"
REF.
54"
REF.
CLOSET
BATH
TILE
SHOWER
60"
30"
LINEN
SHOWER
60"
30"
REMOVE EXISTING MAN DOOR
AND FRAME. FILL IN AND FINISH
WITH MATERIAL TO MATCH
EXISTING.
EXISTING STUCCO
FINISH.
EXISTING
BRICK.
EXISTING
TILE ROOF.
EXISTING BRICK
FIREPLACE CHIMMNY.
1-1/2" DIA. STL. WT.
WELDED STEEL PIPE
GUARDRAIL. SEE DETAIL.
3'-0"
1" STL. PICKETS.
TYP.
4" SPHERE SHALL
NOT PASS THRU
CONCRETE STAIR WALL.
EXISTING STUCCO
FINISH.
EXISTING
BRICK.
EXISTING GARAGE
DOORS TO BE
REMOVED.
FILL IN REMOVED GARAGE
DOOR LOCATIONS WITH MATERIAL
TO MATCH EXISTING. TYP.
5/0X4/0 SL.
NEW WINDOW.
5/0X4/0 SL.
NEW WINDOW.
EXISTING DRIVEWAY.
EXISTING HOUSE.
EXISTING LANDSCAPING.
TYP.
A2.4
Sheet
Scale
Project
Date
No. Revision/Issue Date
PLAN NOTES:
"Seller reserves the right to make any
and all changes due to code
requirements, constructability, HOA
requirements, and or substitute any
material for a material of equal or
greater value at their sole and absolute
discretion. All measurements are
approximate. Home will be built in
substantial accordance with these
plans changes that are not a substantial
deviation from the plan are not
grounds for Buyer to cancel their sales
contract."
IF THIS IS NOT RED
DO NOT COPY
THESE DRAWINGS ARE PROPERTY
OF SAVANT HOMES, INC. AND CAN NOT
BE COPIED, MODIFIED OR DUPLICATED
WITHOUT THE WRITTEN CONSENT OF
SAVANT HOMES, INC.
P.O. BOX 2066 FORT COLLINS, CO. 80522 970-472-5667
1/4"=1'-0"
5/19/17
SENECA REMODEL
REMODEL FOR
4406 SENECA
LOT 14, BLOCK TWO REGENCY PARK P.U.D.
PROJECT:
FORT COLLINS, COLORADO
ELEVATIONS
LEGEND:
EXISTING CONSTRUCTION TO REMAIN.
NEW CONSTRUCTION.
1 FLOOR PLAN REVISION 5-21-17
2 REVISED WINDOW WELLS 5-25-17
3 PDP SUBMITTIAL 6/15/17
DIRECTOR OF COMMUNITY AND NEIGHBORHOOD SERVICES
APPROVED BY THE COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE DIRECTOR ON THIS
DAY OF , A.D. 2017
COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE DIRECTOR
OWNER CERTIFICATION
THE UNDERSIGNED DOES / DO HEREBY CERTIFY THAT I / WE ARE THE LAWFUL OWNERS OF REAL PROPERTY
DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I / WE ACCEPT THE CONDITIONS AND RESTRICTIONS
SET FORTH ON SAID PROJECT DEVELOPMENT PLAN WITHIN THE LIMIT OF DEVELOPMENT BOUNDARY.
LOT 14, BLOCK TWO, REGENCY PARK P.U.D.
NAME DATE
NORTH LEFT SIDE ELEVATION
Scale: 1/4" = 1'-0"
WEST FRONT ELEVATION
Scale: 1/4" = 1'-0"
4 CITY CORRECTIONS 8/11/17
CLOSET
2/10X6/8
2/10X6/8
3/0X6/8
4/0X6/8 BI-FOLD
4/0X6/8 BI-FOLD
5/0X6/8 PAIR
2/10X6/8
2/10X6/8
2/10X6/8
2/10X6/8
4/0X6/8 BI-FOLD
4/0X6/8 BI-FOLD
3/0X6/8
2/10X6/8
2/10X6/8
2/10X6/8
2/10X6/8
48V
1R1S
1R1S
5S
48V
48V
1R1S
32V 32V
1R1S
5S
5S
RESIDENT ROOM
#6
CARPET
RESIDENT ROOM
#1
CARPET
RESIDENT ROOM
#5
CARPET
RESIDENT ROOM
#4
RESIDENT ROOM CARPET
#3
CARPET
RESIDENT ROOM
#2
CARPET
2/10X6/8
POCKET
2/10X6/8
POCKET
2/10X6/8
POCKET
1'-91
2"
1'-9"
6'-6" 3'-6"
3'-6"
3'-83
3'-4 4"
3
4"
5'-31
2" 5'-4
3
4"
3'-6"
1'-61
2"
3'-8
3
4"
4'-3"
2'-1"
4'-1"
4'-1"
3'-6"
ARCHWAY
TO MATCH
EXISTING
7'-101
4"
4'-4 5'-0"
1
2"
7'-0"
2'-41
2"
1'-11"
2'-9
1
2'-6 4"
1
4"
4'-6"
4'-6"
1'-9"
3'-3"
5'-0"
FILL IN WITH LIKE
MATERIAL.
EQUAL EQUAL
1'-91
2"
2'-1"
ROLL IN SHOWER
BASE.
ROLL IN SHOWER
BASE.
2X4 STUD WALL @ 16" O.C.
W/
1
2
" GYP. BD. EA. SIDE.
TYP.
S
S3
WP
S
S3
S3
S3
S3
WP
GFCI
GFCI
S3
S3
GFCI
S3
S
GFCI
F F
F
S S
F
F
F
S3
S3
S
CAT6/TV
S3
S
3
WP
F
SS
GFCI
4'-0"
16'-0" 5'-0"
FIELD VERIFY STEPS TO GRADE
AS PER CODE.
3'-101
4"
FILL IN WITH LIKE
MATERIAL.
FILL IN WINDOW WITH
LIKE MATERIAL.
EXISTING CONSTRUCTION
TO REMAIN. - TYP.
FILL IN ARCHWAY WITH
LIKE MATERIAL.
RELOCATED EXISTING
DBL. OVEN AND CABINET.
NEW MTL. SHELVING.
OWNER SUPPLIED.
2X4 STUD WALL @ 16" O.C.
W/
1
2
" GYP. BD. EA. SIDE.
TYP.
1-1/2" DIA. STL. WT.
WELDED STEEL PIPE
GUARDRAIL. SEE DETAIL.
5/0X4/0 SL. 5/0X4/0 SL.
7'-3" 9'-8 7'-3"
1
2"
3'-6"
ADD NEW BRICK / STUCCO
AS NEEDED TO MATCH EXISTING.
36" CONCRETE
WALL.
1
A2.3
NEW STEPPED TIMBER
WINDOW WELL. - TYP.
GFCI
GFCI
GFCI
GFCI GFCI
GFCI
3S
INSTALL TWO 15" DEEP SHELVES
STARTING AT 36" A.F.F. - 18" APART.
S3
S3
CAT5/TV
CAT5/TV
CAT5/TV
FUTURE
ELEVATOR
EMERGENCY
WHOLE HOUSE
GENERATOR
3'-0"
5'-0"
1-1/2" DIA. STL. WT.
WELDED STEEL PIPE
GUARDRAIL. SEE DETAIL.
1" STL. PICKETS.
TYP.
8" THK. CONCRETE WALL.
SEE STRUCTURALS.
4" THK. CONCRETE SLAB.
SLOPE TO CENTER DRAIN.
SEE STRUCTURALS.
CONCRETE STEPS.
AS PER CODE.
SEE STRUCTURALS.
1'-0"
71
8"
VERIFY
DRAIN. ATTACH TO SUMP PIT
IN STORAGE AREA.
6"
GRADE
3'-0"
4" SPHERE SHALL
NOT PASS THRU
NOTE: PROVIDE HANDRAIL
@ STAIRS AS PER
LOCAL CODES
DOWEL REBAR
INTO EXISTING
FOUNDATION.
LANDSCAPE BED.
3'-0"
FOOTINGS AS PER
STRUCTURAL
ENGINEER. TYP.
A2.3
MAIN FLOOR
Sheet
Scale
Project
Date
No. Revision/Issue Date
PLAN NOTES:
"Seller reserves the right to make any
and all changes due to code
requirements, constructability, HOA
requirements, and or substitute any
material for a material of equal or
greater value at their sole and absolute
discretion. All measurements are
approximate. Home will be built in
substantial accordance with these
plans changes that are not a substantial
deviation from the plan are not
grounds for Buyer to cancel their sales
contract."
IF THIS IS NOT RED
DO NOT COPY
THESE DRAWINGS ARE PROPERTY
OF SAVANT HOMES, INC. AND CAN NOT
BE COPIED, MODIFIED OR DUPLICATED
WITHOUT THE WRITTEN CONSENT OF
SAVANT HOMES, INC.
P.O. BOX 2066 FORT COLLINS, CO. 80522 970-472-5667
1/4"=1'-0"
NEW WORK MAIN FLOOR PLAN
SCALE: 1/4" = 1'-0"
GENERAL NOTES:
1) ALL SUB CONTRACTORS REFER TO COVER SHEET FOR GENERAL NOTES.
5/19/17
SENECA REMODEL
REMODEL FOR
4406 SENECA
LOT 14, BLOCK 2 REGENCY PARK SUBDIVISON
PROJECT:
2) ALL DIMENSIONS SHALL BE FIELD VERIFIED AND ARE THE SOLE RESPONSIBLITY OF
EACH TRADE TO VERIFY PRIOR TO CONSTRUCTION. ANY DISCREPENCIES SHOULD BE
REPORTED TO THE BUIDLING SUPERITENDENT BEFORE PROCEDING.
SUBDIVISION 1631, PARCEL 97344-11-014
FORT COLLINS, COLORADO
NEW WORK
PLAN
LEGEND:
EXISTING CONSTRUCTION TO REMAIN.
EXISTING CONSTRUCTION TO REMOVED.
NEW CONSTRUCTION.
EXTERIOR STAIRWELL / GUARDRAIL SECTION
SCALE: 1/4" = 1'-0"
1 FLOOR PLAN REVISION 5-21-17
1
2 ADDED WINDOW WELL 5-25-17
ADDED ELECTRICAL
ADDED ELECTRICAL
ADDED ELECTRICAL AND
SHELVING.
REVISED ARCH AND
ADDED FUTURE ELEVATOR.
ADDED GENERATOR.
REVISED DESIGN.
3 PDP SUBMITTIAL 6/15/17
4 CITY CORRECTIONS 8/11/17
NEEDED FOR NEW
CONSTRUCTION.
REMOVE SHELVING AS
NEEDED FOR NEW
CONSTRUCTION.
REMOVE EXISTING
DOORS. -TYP.
REMOVE WALL AS
NEEDED FOR NEW
CONSTRUCTION.
TYP.
REMOVE EXISTING
WINDOW AND FILL
IN WITH MATERIAL
TO MATCH EXISTING.
REMOVE EXISTING TUB
AND DECK. RELOCATE
PLUMBING AS NEEDED
FOR NEW CONSTRUCTION.
REMOVE WALL AS
NEEDED FOR NEW
ARCHWAY.
REMOVE HANDRAIL AS
NEEDED FOR NEW
CONSTRUCTION.
REMOVE EXISTING
COUNTERTOP, SINKS
AND CABINETS AS
NEEDED FOR NEW
CONSTRUCTION.
REMOVE EXISTING
DOOR.
REMOVE EXISTING TUB
AND DECK. RELOCATE
PLUMBING AS NEEDED
FOR NEW CONSTRUCTION.
REMOVE EXISTING
COUNTERTOP, SINKS
AND CABINETS AS
NEEDED FOR NEW
CONSTRUCTION.
REMOVE EXISTING TOILET.
RELOCATE PLUMBING AS NEEDED
FOR NEW CONSTRUCTION.
REMOVE EXISTING SHOWER.
RELOCATE PLUMBING AS NEEDED
FOR NEW CONSTRUCTION.
REMOVE AND RELOCATE EXISTING
DBL. OVEN AND CABINET. SEE NEW
CONSTRUCTION FLOOR PLAN.
REMOVE EXISTING
CABINETS AS SHOWN.
A2.2
MAIN FLOOR
Sheet
Scale
Project
Date
No. Revision/Issue Date
PLAN NOTES:
"Seller reserves the right to make any
and all changes due to code
requirements, constructability, HOA
requirements, and or substitute any
material for a material of equal or
greater value at their sole and absolute
discretion. All measurements are
approximate. Home will be built in
substantial accordance with these
plans changes that are not a substantial
deviation from the plan are not
grounds for Buyer to cancel their sales
contract."
IF THIS IS NOT RED
DO NOT COPY
THESE DRAWINGS ARE PROPERTY
OF SAVANT HOMES, INC. AND CAN NOT
BE COPIED, MODIFIED OR DUPLICATED
WITHOUT THE WRITTEN CONSENT OF
SAVANT HOMES, INC.
P.O. BOX 2066 FORT COLLINS, CO. 80522 970-472-5667
1/4"=1'-0"
EXISTING MAIN FLOOR DEMO PLAN
SCALE: 1/4" = 1'-0" GENERAL NOTES:
1) ALL SUB CONTRACTORS REFER TO COVER SHEET FOR GENERAL NOTES.
5/19/17
SENECA REMODEL
REMODEL FOR
4406 SENECA
LOT 14, BLOCK 2 REGENCY PARK SUBDIVISON
PROJECT:
2) ALL DIMENSIONS SHALL BE FIELD VERIFIED AND ARE THE SOLE RESPONSIBLITY OF
EACH TRADE TO VERIFY PRIOR TO CONSTRUCTION. ANY DISCREPENCIES SHOULD BE
REPORTED TO THE BUIDLING SUPERITENDENT BEFORE PROCEDING.
SUBDIVISION 1631, PARCEL 97344-11-014
FORT COLLINS, COLORADO
EXIST / DEMO
PLAN
LEGEND:
EXISTING CONSTRUCTION TO REMAIN.
EXISTING CONSTRUCTION TO REMOVED.
1 FLOOR PLAN REVISION 5-21-17
2 ADDED WINDOW WELL. 5-25-17
3 PDP SUBMITTIAL 6/15/17
4 CITY CORRECTIONS 8/11/17
BATH
TILE
CAREGIVER
BEDROOM
CARPET
CAREGIVER
STORAGE
CONCRETE
CAREGIVER
BATH
TILE
6/0X6/8 BI-FOLD
5/0X6/8 BI-FOLD
3/0X6/8
3/0X6/8
3/0X6/8
2/10X6/8
2/10X6/8
SHOWER
60"
30"
2'-6" 1'-7" 1'-10"
3'-6"
4'-6"
2'-01
2"
2'-41
2"
2'-6" 1'-9"
2'-11"
2'-1" 11
1
2"
4'-6" 1'-5"
5'-0"
2'-6"
4'-0"
16'-0" 5'-0"
FIELD VERIFY STEPS TO GRADE
AS PER CODE.
ROLL IN SHOWER
BASE.
2X4 FLOATING STUD WALL @
16" O.C. W/
1
2
" GYP. BD. EA.
SIDE. - TYP.
FILL IN WITH LIKE
MATERIAL.
8" THK. CONCRETE WALL
W/ CONCRETE STEPS AS
PER CODE AND STRUCTURAL
ENGINEER.
SUMP PIT WITH PUMP
ATTACHED TO EXTERIOR
DRAIN. DRAIN TO LEACH
FIELD IN YARD.
EXISTING FURRDOWN.
TYP.
EXISTING WALLS.
TYP.
EXISTING CONCRETE
FOUNDATION WALLS.
TYP.
GARAGE ABOVE
EXTERIOR DRAIN. SLOPE
CONCRETE TO DRAIN.
1
4
"
PER FOOT.
EMERGENCY EXIT ONLY.
1'-8"
S3
S3
S3
S
3
S3
S3
F WP
S
3
S3
GFCI
S4
S4
2X4 STUD WALL @ 16" O.C.
W/
1
2
" GYP. BD. EA. SIDE.
TYP.
CUT IN NEW DOOR
INTO EXISTING WALL.
1'-10"
EXISTING CONSTRUCTION
TO REMAIN. - TYP.
S
3' TALL.
3' NEW PLANTER AREA.
3'-6"
S3
S3S
4
S3
S3
S4
S4
S4
NEW STEPPED TIMBER
WINDOW WELL.
GFCI
CAT5/TV
CAT5/TV
FUTURE
ELEVATOR
3'-0"
5'-0"
uc
WP
SD
SINGLE POLE SWITCH
3-WAY SWITCH
DIMMER SWTICH
GARAGE DOOR OPENER
GARBAGE DISPOSAL
S3
SG
SGD
110V OUTLET
220V OUTLET
HALF-SWITCHED OUTLET
GFCI OUTLET
WATER PROOF 110V
110V FLOOR OUTLET
FL
LIGHTS
SURFACE MOUNT LIGHT
RECESSED CAN LIGHT
WALL MOUNT LIGHT
PENDANT LIGHT
WALL SCONCE
KEYLESS LIGHT
K
T THERMOSTAT
F FAN
FAN/LIGHT COMBO
PHONE
TELEVISION
CEILING FAN
CEILING FAN w/ LIGHT
NOTES: OUTLETS NOT SHOWN, BUT WILL BE
INSTALLED PER CODE. IF OUTLETS ARE
SHOWN, THEY ARE ON PLAN FOR SPECIFIC
LOCATION
NOTE 1: WIRE SMOKE DETECTORS IN
SERIES
NOTE 2: ALL OUTLETS AND SWITCHES TO BE
INSTALLED PER LOCAL AND GOVERNING
CODES
NOTE 3: VERIFY CABINET LAYOUT w/ NOTES
ON FLOOR OR w/ SUPERINTENDENT
NOTE 4: VERIFY ALL DOOR SWINGS WITH
NOTES ON JAMBS OR w/ SUPERINTENDENT
NOTE 5: PROVIDE ONE WORKING OUTLET ON
EACH LEVEL & 220V UPON COMPLETION OF
ROUGH-IN
NOTE 6: WIRE ALL APPLIANCES SHOWN ON
PLAN
NOTE 7: WIRING DIAGRAM FOR
CONCEPTUAL, WIRE ACCORDING TO LOCAL
CODES
NOTES
UNDER CABINET LIGHT
OUTLETS
SWITCHES
F
MISC. FIXTURES
S
WATER PROOF RECESSED
CAN LIGHT
W
LIGHT BAR (4) LIGHT
LIGHT BAR (3) LIGHT
D DEDICATED CURCUIT
4' FLOU. STRIP LIGHT
GFCI
4' FLOU. LIGHT
A2.1
BASEMENT
Sheet
Scale
Project
Date
No. Revision/Issue Date
PLAN NOTES:
"Seller reserves the right to make any
and all changes due to code
requirements, constructability, HOA
requirements, and or substitute any
material for a material of equal or
greater value at their sole and absolute
discretion. All measurements are
approximate. Home will be built in
substantial accordance with these
plans changes that are not a substantial
deviation from the plan are not
grounds for Buyer to cancel their sales
contract."
IF THIS IS NOT RED
DO NOT COPY
THESE DRAWINGS ARE PROPERTY
OF SAVANT HOMES, INC. AND CAN NOT
BE COPIED, MODIFIED OR DUPLICATED
WITHOUT THE WRITTEN CONSENT OF
SAVANT HOMES, INC.
P.O. BOX 2066 FORT COLLINS, CO. 80522 970-472-5667
1/4"=1'-0"
NEW BASEMENT PLAN
SCALE: 1/4" = 1'-0" GENERAL NOTES:
1) ALL SUB CONTRACTORS REFER TO COVER SHEET FOR GENERAL NOTES.
5/19/17
SENECA REMODEL
REMODEL FOR
4406 SENECA
LOT 14, BLOCK 2 REGENCY PARK SUBDIVISON
PROJECT:
2) ALL DIMENSIONS SHALL BE FIELD VERIFIED AND ARE THE SOLE RESPONSIBLITY OF
EACH TRADE TO VERIFY PRIOR TO CONSTRUCTION. ANY DISCREPENCIES SHOULD BE
REPORTED TO THE BUIDLING SUPERITENDENT BEFORE PROCEDING.
SUBDIVISION 1631, PARCEL 97344-11-014
FORT COLLINS, COLORADO
NEW WORK
LEGEND:
EXISTING CONSTRUCTION TO REMAIN.
EXISTING CONSTRUCTION TO REMOVED.
NEW CONSTRUCTION.
ELECTRICAL LEGEND:
1 FLOOR PLAN REVISION 5-21-17
2 ADDED WINDOW WELL. 5-25-17
ADDED ELECTRICAL
ADDED WINDOW WELL.
REVISED DOOR LOCATION,
ADDED FUTURE ELEVATOR.
REVISED DESIGN AND LOCATION,
3 PDP SUBMITTIAL 6/15/17
4 CITY CORRECTIONS 8/11/17
NEEDED TO INSTALL NEW
SUMP PIT AND DRAIN LINES.
REMOVE WALLS AS
NEEDED FOR NEW
CONSTRUCTION.
DEMO EXISTING WINDOW
WELL AND EARTH AS NEEDED
FOR NEW STACKED TIMBER
WINDOW WELL.
DEMO EXISTING WINDOW
WELL AND EARTH AS NEEDED
FOR NEW CONSTRUCTION.
DEMO EXISTING WINDOW
WELL AND EARTH AS NEEDED
FOR NEW STACKED TIMBER
WINDOW WELL.
A2.0
BASEMENT
Sheet
Scale
Project
Date
No. Revision/Issue Date
PLAN NOTES:
"Seller reserves the right to make any
and all changes due to code
requirements, constructability, HOA
requirements, and or substitute any
material for a material of equal or
greater value at their sole and absolute
discretion. All measurements are
approximate. Home will be built in
substantial accordance with these
plans changes that are not a substantial
deviation from the plan are not
grounds for Buyer to cancel their sales
contract."
IF THIS IS NOT RED
DO NOT COPY
THESE DRAWINGS ARE PROPERTY
OF SAVANT HOMES, INC. AND CAN NOT
BE COPIED, MODIFIED OR DUPLICATED
WITHOUT THE WRITTEN CONSENT OF
SAVANT HOMES, INC.
P.O. BOX 2066 FORT COLLINS, CO. 80522 970-472-5667
1/4"=1'-0"
EXISTING / DEMO BASEMENT PLAN
SCALE: 1/4" = 1'-0" GENERAL NOTES:
1) ALL SUB CONTRACTORS REFER TO COVER SHEET FOR GENERAL NOTES.
5/19/17
SENECA REMODEL
REMODEL FOR
4406 SENECA
LOT 14, BLOCK 2 REGENCY PARK SUBDIVISON
PROJECT:
2) ALL DIMENSIONS SHALL BE FIELD VERIFIED AND ARE THE SOLE RESPONSIBLITY OF
EACH TRADE TO VERIFY PRIOR TO CONSTRUCTION. ANY DISCREPENCIES SHOULD BE
REPORTED TO THE BUIDLING SUPERITENDENT BEFORE PROCEDING.
SUBDIVISION 1631, PARCEL 97344-11-014
FORT COLLINS, COLORADO
EXIST / DEMO
LEGEND:
EXISTING CONSTRUCTION TO REMAIN.
EXISTING CONSTRUCTION TO REMOVED.
1 FLOOR PLAN REVISION 5-21-17
2 REVISED WINDOW WELLS 5-25-17
3 PDP SUBMITTIAL 6/15/17
4 CITY CORRECTIONS 8/11/17
EXISTING
ELECTRICAL
METER.
E
E
E
G
G
G
EXISTING
GAS METER.
W
W
W
W
S
S
S
9'-0"
UTILITY
EASEMENT.
EXISTING LANDSCAPING
TO REMAIN AND BE PROTECTED.
TYP. - U.N.O.
10'-0"
A1.0
SITE PLAN
Sheet
Scale
Project
Date
No. Revision/Issue Date
PLAN NOTES:
"Seller reserves the right to make any
and all changes due to code
requirements, constructability, HOA
requirements, and or substitute any
material for a material of equal or
greater value at their sole and absolute
discretion. All measurements are
approximate. Home will be built in
substantial accordance with these
plans changes that are not a substantial
deviation from the plan are not
grounds for Buyer to cancel their sales
contract."
IF THIS IS NOT RED
DO NOT COPY
THESE DRAWINGS ARE PROPERTY
OF SAVANT HOMES, INC. AND CAN NOT
BE COPIED, MODIFIED OR DUPLICATED
WITHOUT THE WRITTEN CONSENT OF
SAVANT HOMES, INC.
P.O. BOX 2066 FORT COLLINS, CO. 80522 970-472-5667
1/4"=1'-0"
SITE: = 10,468 SF.
5/19/17
SENECA REMODEL
REMODEL FOR
4406 SENECA
LOT 14, BLOCK TWO REGENCY PARK P.U.D.
PROJECT:
FORT COLLINS, COLORADO
LEGEND:
EXISTING CONSTRUCTION TO REMAIN.
NEW CONSTRUCTION.
1 FLOOR PLAN REVISION 5-21-17
2 REVISED WINDOW WELLS 5-25-17
3 PDP SUBMITTIAL 6/15/17
DIRECTOR OF COMMUNITY AND NEIGHBORHOOD SERVICES
APPROVED BY THE COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE DIRECTOR ON THIS
DAY OF , A.D. 2017
COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE DIRECTOR
OWNER CERTIFICATION
THE UNDERSIGNED DOES / DO HEREBY CERTIFY THAT I / WE ARE THE LAWFUL OWNERS OF REAL PROPERTY
DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I / WE ACCEPT THE CONDITIONS AND RESTRICTIONS
SET FORTH ON SAID PROJECT DEVELOPMENT PLAN WITHIN THE LIMIT OF DEVELOPMENT BOUNDARY.
LOT 14, BLOCK TWO, REGENCY PARK P.U.D.
NAME DATE
HOUSE: = 5,300 SF.
GARAGE: = 493 SF.
FRONT PORCH = 112 SF.
POOL ROOM = 391 SF.
EXISTING CONCRETE WALK: = 482 SF.
EXISTING CONCRETE DRIVE: = 1,192 SF.
NEW CONCRETE WALK/STAIRWAY: = 274 SF.
4 CITY CORRECTIONS 8/11/17
GENERAL NOTES:
1. RESIDENTS WILL NOT BE ALLOWED TO OWN CARS.
2. A MAXIMUM OF 8 RESIDENTS WILL BE ALLOWED PLUS CARETAKER.
3. MAXIMUM OF THREE EMPLOYEES WITH ONE CAR EACH. PARKING PROVIDED
SITE PLAN NOTES:
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL
PLANS, AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY
THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION
INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND
SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS,
AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS
AND OTHER SURVEY INFORMATION.
4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE
SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS, IN
CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT
SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE
PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER
MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE
SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES.
5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN
ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS.
6. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE
REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A
CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY.
SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY
DIFFUSION.
7. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING
DOCUMENT AND MUST BE APPROVED BY SEPERATE CITY PERMIT PRIOR TO
CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A
SPECIFIC VARIANCE IS GRANTED BY THE CITY.
8. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS.
ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM.
9. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE
RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT
ALL DESIGNATED ACCESSIBLE PARKING SPACES. ACCESSIBLE PARKING
SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE
ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH
NO MORE THAN 1:48 CROSS SLOPE.
10. THE PROPERTY OWNER SHALL BE RESPONSIBLE FOR SNOW REMOVAL ON
ALL STREET SIDEWALKS ADJACENT TO THE RESIDENCE.
11. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO
CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS,
DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS
STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF
COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST
CERTIFICATE OF OCCUPANCY.
12. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND
APPROVED BY THE FIRE OFFICAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE
OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL. APPROVED
SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING
FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO
IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS
BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND
LEGIBLE CONDITION AT ALL TIMES AND BE REPLACED OR REPAIRED WHEN
NECESSARY TO PROVIDE ADEQUATE VISIBILITY.
STREET TREE NOTES:
1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES
OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN
THE PUBLIC RIGHT-OF-WAY. THIS INCULDES ZONES BETWEEN THE SIDEWALK
AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE
THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT
IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION
(SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES
SND A HOLD ON CERTIFICATE OF OCCUPANCY.
2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT
THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE
INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE
PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE.
3. STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN
ACCORDANCE WITH ALL CITY CODES AND POLICES, ALL TREE PRUNING AND
REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORT COLLINS LICENSED
ARBORS WHERE REQUIRED BY CODE. STREET TREES SHALL BE SUPPLIED AND
PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR.
4. THE DEVELOPER SHALL REPLACE DEAD OR DYING TREES AFTER
PLANTING UNTIL FINAL MAINTANCE INSPECTION AND ACCEPTANCE BY THE
CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE
PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF
ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE.
5. SUBJECT TO APPROVAL BY THE CITY FORESTER - STREET TREE LOCATIONS
MAY BE ADJUSTED TO ACCOMMADTE DRIVEWAY LOCATIONS, UTILITY
SEPERATIONS BEWTWEEN TREES, STREET SIGNS AND STREET LIGHTS, STREET
TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE.
QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS
APPROVED BY THE CITY TO MEET SEPERATION STANDARDS.
TREE PROTECTION NOTES:
1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY
NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS
NOTED ON THESE PLANS FOR REMOVAL.
2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE. THERE SHALL BE NO
CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR
FORESTER HAS EVALUATED AND APPROVED THE DISTURBRANCE.
3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT
COLLINS FORESTRY STANDARDS. TREE PRUING AND REMOVAL SHALL BE
PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS
ARBORIST LICENSE WHERE REQUIRED BY CODE.
4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND
ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE ORANGE
FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-
POSTS. NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF(1/2) OF
THE DRIP LINE. EHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR
MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED
TREE PROTECTED ZONE.
5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT. THE APPLICANT SHALL
PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND
DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT,
CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A
TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO
ANY PROTECTED TREE.
7. LARGE PROPERTY AREA CONTAINING PROTECTED TREES AND SEPERATED
FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHT-OF-WAY AND
UTILIT EASEMENTS MAY BE "RIBBONED OFF". RATHER THAN ERECTING
PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3)
ABOVE. THIS MAY BE ACCOMPLSHED BY PLACING METAL T-POST STAKES A
MAXIMUM OF FITY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-
TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED.
8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND
FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE
ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED
EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE
AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK)
AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE
CHART BELOW.
TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET)
0-2
3-4
5-9
10-14
15-19
OVER 19
1
2
5
10
12
15
9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD
NESTING SEASON (FEB 1- JULY 31) OR CONDUCT A SURVEY OF TREES
ENSURING NO ACTIVE NESTS IN THE AREA.
FOR FOUR SPACES.
GENREAL LANDSCAPE NOTES:
1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE-
FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND
SPREAD APPROPRIATE TO THE SPECIES AS DIFINED BY THE AMERICAN
ASSOCIATION OF NURSRYMAN (AAN) STANDARDS. ALL TREES SHALL BE BALL
AND BURLAP OR EQUIVALENT.
2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB
BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION
SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE
CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSANCE
OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN
AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES,
INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC
DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE
APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM
SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL
PLANT MATERIAL.
3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED
DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON
AREAS REQUIRING REVEGETATION AND LANDSCAPING.
4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED
IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE
AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE THROUGHLY
LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT (8) INCHES AND SOIL
AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL
LANDSCAPEAREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING
OR OTHER SUITABLE METHOD. AT A RATE OF AT LEAST THREE (3) CUBIC YARDS
OF SOIL AMENDMENT PER ONE THOUSAND 91,000) SQUARE FEET OF LANDSCAPE
AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. A
WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED
AREAS, OR AREAS TO BE PLANED, HAVE BEEN THOROUGHLY LOOSENED AND
THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN
SECTION 12-132.
5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED
ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO
ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING
FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE
SECURED WITH AN IRREVOCABLE LETTER OF CREDIT. PERFORANCE BOND, OR
ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND
LABOR PRIOR TO ISSANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY
BUILDING IN SUCH PHASE.
6. MAINTANCE: TREES, AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS
AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE
CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS
PARKING. BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT,
LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY
RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING
ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE
FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES
SUCH AS FENCES AND WALLS SHALL BE REPIRED AND REPLACED
PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION.
7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE
REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE
REQUIREMENTS OF THESE PLANS.
8. THE FOLLOWING SEPERATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS
AND UTILITIES:
40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS
15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS
10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER
MAIN LINES.
6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER
SERVICE LINES.
4 FEET BETWEEN SHRUBS AND PUBLIC WATERAND SANITARY AND STORM
SEWER LINES.
4 FEET BETWEEN TREES AND GAS LINES.
9. ALL STREET TREES SHALL BE PLACEDD A MINIMUM EIGHT (8) FEET AWAY FROM
THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a).
10. PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT
DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO
STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE
ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT WITH THE
EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST BRANCH IS AT
LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR
EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN.
FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES
SUCH AS FENCES AND WALLS SHALL BE REPIRED AND REPLACED
PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION.
11. THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL
PLAN ELEMENTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE, AND
OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE
INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN.
12. MINOR CHANGES IN SPEICES AND PLANT LOCATIONS MAY BE MADE DURING
CONSTRUCTION - AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY.
OVERALL QUANTITY, QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENT
WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES
INCLUDED IN THE PLANT LIST. SPECIES AND QUANTITIES ILLUSTRATED SHALL BE
PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE
WRITTEN APROVAL BY THE CITY PRIOR TO INSTALLATION.
13. ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE
INCHES.
NATIVE SEEDING NOTES:
DOES NOT APPLY
FLOODPLAIN AND FLOODWAY NOTES:
DOES NOT APPLY - (PROJECT NOT IN FLOODPLAIN)
4. THE EXISTING DRIVEWAY EXCEEDS THE 40% COVERAGE, NO ADDITIONAL PARKING
WILL BE ADDED OR NEEDED.
5 CITY CORRECTIONS 8/25/17
6 CITY CORRECTIONS 8/30/17
FRAMING:
REVISIONS:
# DATE: DESCRIPTION:
GLAZING:
B. TEMPERED GLASS SHALL BE INSTALLED IN ALL WINDOWS AND DOORS AS NEEDED TO MEET
CODE.
G. PROVIDE FIRE BLOCKING AS NEEDED IN ACCODANCE WITH R602.8 OF THE 2006 IRC.
THERMAL BARRIER:
ELECTRICAL:
A. INFORMATION AND LAYOUTS SHOWN ON DRAWINGS ARE ONLY SCHEMATIC IN DESIGN AND SHALL
BE REVIEWED BY ELECTRICAL CONTRACTOR, SUPPLIERS AND BUILDING OFFICALS FOR
COMPLIANCE WITH GOVERNING CODES AND GOOD COMMON CONSTRUCTION PRACTICES.
B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI) MEETING THE
REQUIREMENTS OF ALL GOVERNING CODES. ALL OUTDOOR, BATH AND NON-DEDICATED GARAGE
WALL RECEPTACLIES SHALL BE PROVIDED WITH GROUND FAULT CIRCUIT PROTECTION..
F. INSTALL ALL EQUIPMENT AND APPLIANCES AS PER MANUFACTURES RECOMMEDATIONS.
VERIFY AND PROVIDE PROPER ELECTRICAL SUPPLIES TO EACH.
G. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE AND CARBON DETECTORS MEETING THE
REQUIREMENTS OF ALL GOVERNING CODES. SMOKE DECTORS SHALL BE 110 VOLT POWERED,
AND EQUIPPED WITH A BATTERY BACKUP AND SOUND AN ALARM AUDIBLE IN ALL SLEEPING
AREAS. WHEN MULTIPLE ALARMS ARE REQUIRED IN A DWELLING UNIT, THE ALARM DEVICES
SHALL BE INTERCONNECTED SO ACTUATION OF ONE ALARM ACTIVATES ALL ALARMS.
B. PROVIDE THERMAL BUILDING INSULATION AT ASSEMBLIES ADJACENT TO EXTERIOR SPACES IN
ACCORDANCE WITH MANUFACTURES SPECIFIACTIONS, LOCAL ORDINANCES AND CODES.
H. ALL ENGINEERED WOOD PRODUCTS SHALL BE HANDLED AND INSTALLED IN STRICT
ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND RECOMMENDATIONS.
I. ALL WOOD PLATES BEARING ON CONCRETE OR MASONRY SHALL BE DECAY-RESISTANT
AS REQUIRED BY GOVERNING COEDS..
SYMBOLS:
1
A2.1
SHEET NUMBER
DIRECTION ELEVATION OR
SECTION KEY.
= ROOF PITCH
12
8
= ANGLE
CL = CENTERLINE
HB = FREEZE PROOF HOSE BIB
G = GAS LINE STUB W/ CUTOFF.
O = ROUND OR DIAMETER
1R1S = CLOSET - (1) ROD (1) SHELF
2R2S = CLOSET - (2) RODS (2) SHELVES
5S = (5) STACK SHELVES
= LAVATORY - SEE SPEC.
= WATER CLOSET - SEE SPEC.
= TUB/SHOWER - SEE SPEC.
DW
= DOUBLE SINK- SEE SPEC.
= SINGLE SINK- SEE SPEC.
= RANGE / COOKTOP- SEE SPEC.
= DISHWASHER- SEE SPEC.
REF. = REFRIGERATOR- SEE SPEC.
6060SL = WINDOW (60"X60" SLIDER)
2/6X6/8 = DOOR (2'-8"X6'-8")
FP = FIREPLACE- SEE SPEC.
2. 2015 INTERNATIONAL RESIDENTIAL CODE (IRC)
3. 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
4. 2015 INTERNATIONAL MECHANICAL CODE (IMC)
5. 2015 INTERNATIONAL FUEL GAS CODE (IFGC).
6. 2015 INTERNATIONAL PLUMBING CODE IPC AS AMENDED BY THE STATE OF COLORADO.
7. 2017 INTERNATIONAL ELECTRIC CODE. NEC AS AMENDED BY THE STATE OF COLORADO
8. ACCESSIBILITY: STATE LAW CRS 9-5 & ICC / ANSI A117.1-2009.
9. SNOW LOAD - LIVE LOAD: 30 PSF / GROUND SNOW LOAD : 30 PSF.
10. FROST DEPTH; 30 INCHES.
11. WIND LOAD: 100 MPH. - 3 SECOND GUST.
12. SESMIC DESIGN CATAGORY B
13. ENERGY CODE COMPLIANCE - 2015 (IECC) RESIDENTIAL CHAPTER (CLIMATE ZONE 5).
TO BOTTOM OF TRUSSES PRIOR TO INSTALLING SHEETROCK, TYPICAL ALL EXTERIOR WALLS.
REMODEL FOR
LOT 14, BLOCK TWO - REGENCY PARK P.U.D.
FORT COLLINS, COLORADO
PROJECT:
4406 SENECA
1 5/21/17 Floor plan redesign mtg. 5-10-17
5/10/17
2 5/25/17 Added window well.
14. OCCUPANCY R4
3 6/15/17 PDP SUBMITTAL
4 8/11/17 CITY PDP MARKUP CORRECTIONS
A. PROVIDE FIRE PROTECTION AS PER CODE -IFC 903.2.8.3 PFA NOTES THAT THE BUILDING WILL BE
EQUIPPED WITH A FIRE SPRINKLER SYSTEM AS REQUIRED BY IFC 903.3.1.2 FOR CONDITION 2,
FIRE SPRINKLER / FIRE ALARM & DETECTION:
GROUP R-4 OCCUPANCIES. ATTICS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 903.2.8.3.2
C. FIRE ALARMS SYSTEMS AND SMOKE ALARMS SHALL BE INSTALLED IN GROUP R-4 OCCUPANCIES
AS REQUIRED IN SECTIONS 907.2.10.1 THROUGH 907.2.10.3
A2.4 - EXTERIOR ELEVATIONS
PERMITS:
1. PERMITS SHALL BE OBTAINED FOR ALL WORK AS PER FEDERAL, STATE, CITY AND LOCAL BUILDING CODES.