HomeMy WebLinkAboutBOARDWALK OFFICE BUILDING - PDP - PDP170032 - SUBMITTAL DOCUMENTS - ROUND 2 - LANDSCAPE PLANKEY
SHADE/CANOPY TREES -
QTY RATIO SCIENTIFIC/COMMON NAME HEIGHT WIDTH
7
Gleditsia triacanthos inermis 'Shademaster'
HONEYLOCUST, SHADEMASTER (GTI)
Tilia americana 'Redmond'
LINDEN, REDMOND (TAN)
Juniperus scopulorum 'Skyrocket'
JUNIPER, SKY ROCKET (JSM)
3 12.0% 50'
2 8.0%
40'
50' 40'
Ulmus x 'Accolade'
2 8.0% ELM, ACCOLADE (UAC) 50' 40'
11 EVERGREEN TREES -
11 44.0% 20' 6'
7 ORNAMENTAL TREES -
Malus Royal Raindrops
7 28.0% CRABAPPLE, ROYAL RAINDROPS (MRR) 20' 15'
11 EVERGREEN SHRUBS -
DECIDUOUS SHRUBS -
Syringa patula 'Miss Kim'
LILAC, MISS KIM DWARF (SPK)
18 --- 3' 3'
Caryopteris x clandonensis 'Blue Mist'
12 SPIREA, BLUE MIST (CCM) 4'
4'
Euonymus alatus 'Compactus'
BURNING BUSH, DWARF (EAC)
14 --- 4' 4'
PERENNIALS/GRASSES -
Bouteloua gracilis 'Blonde Ambition'
GRASS, BLONDE AMBITION GRAMA (BGA)
Calamagrostis acutiflora 'Karl Foerster'
---GRASS, FEATHER REED (CAF)
23 ---
116
3' 2'
5' 2'
Hemerocallis 'Stella D'Oro'
--- DAYLILY, STELLA D'ORO (HSD)
90 3' 2'
44
229
---
Juniperus sabina 'Calgary Carpet'
JUNIPER, CALGARY CARPET (JSC) 1.5' 8'
11 ---
ABBREV.
GTI
TAN
JSM
UAC
MRR
SPK
CCM
EAC
BGA
KEY
SHADE/CANOPY TREES -
QTY RATIO SCIENTIFIC/COMMON NAME HEIGHT WIDTH SIZE NOTES
7
Gleditsia triacanthos inermis 'Shademaster'
HONEYLOCUST, SHADEMASTER (GTI)
Tilia americana 'Redmond'
LINDEN, REDMOND (TAN)
Juniperus scopulorum 'Skyrocket'
JUNIPER, SKY ROCKET (JSM)
50' 2.0" cal. BB
2.0" cal. BB
6' BB FULL SPECIMEN, EVENLY
AND WELL BRANCHED
3 12.0%
2 8.0%
40'
50' 40'
Ulmus x 'Accolade'
2 8.0% ELM, ACCOLADE (UAC) 50' 40' 2.0" cal. BB
WELL BRANCHED W/ STRAIGHT
TRUNK & CENTRAL LEADER
WELL BRANCHED W/ STRAIGHT
TRUNK & CENTRAL LEADER
11 EVERGREEN TREES -
11 44.0% 20' 6'
7 ORNAMENTAL TREES -
Malus Royal Raindrops
CRABAPPLE, ROYAL RAINDROPS (MRR)
FULL SPECIMEN, EVENLY
7 28.0% 20' 15' AND WELL BRANCHED
1.5" cal. BB
WELL BRANCHED W/ STRAIGHT
TRUNK & CENTRAL LEADER
11 EVERGREEN SHRUBS -
DECIDUOUS SHRUBS -
Syringa patula 'Miss Kim'
LILAC, MISS KIM DWARF (SPK)
5 Gallon FULL SPECIMEN, EVENLY
AND WELL BRANCHED
18 --- 3' 3'
Caryopteris x clandonensis 'Blue Mist'
SPIREA, BLUE MIST (CCM) 5 Gallon
FULL SPECIMEN, EVENLY
12 4' AND WELL BRANCHED
4'
Euonymus alatus 'Compactus'
BURNING BUSH, DWARF (EAC)
--- 5 Gallon FULL SPECIMEN, EVENLY
14 4' AND WELL BRANCHED
4'
PERENNIALS/GRASSES -
Bouteloua gracilis 'Blonde Ambition'
GRASS, BLONDE AMBITION GRAMA (BGA)
Calamagrostis acutiflora 'Karl Foerster'
GRASS, FEATHER REED (CAF)
1 Gallon
1 Gallon
WELL ROOTED
---WELL ROOTED
23 ---
116
3' 2'
5' 2'
Hemerocallis 'Stella D'Oro'
DAYLILY, STELLA D'ORO (HSD) 1 Gallon
90 --- 3' 2' WELL ROOTED
44
229
---
Juniperus sabina 'Calgary Carpet'
JUNIPER, CALGARY CARPET (JSC)
5 Gallon FULL SPECIMEN, EVENLY
1.5' 8' AND WELL BRANCHED
11 ---
ABBREV.
GTI
TAN
JSM
UAC
MRR
SPK
CCM
EAC
BGA
CAF
HSD
JSC
3
NOTES, SCHEDULES & DETAILS
Sheet Number:
Fort Collins, CO
Boardwalk Office
Building
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Behtroud,CO 80513
TEL
WEB
970.532.5891
TBGroup.us
PROJECT TITLE
REVISIONS
ISSUE DATE
SHEET TITLE
SHEET INFORMATION
DATE
SEAL
August 22, 2017
DATE
PREPARED FOR
r4 Architects
226 Remington Street
Suite 3
Fort Collins CO 80524
Staff Comments 10.17.17
General Landscape Notes
GENERAL LANDSCAPE NOTES:
1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES
AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR EQUIVALENT.
2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN
MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED
WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION
SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS
OF THE INDIVIDUAL PLANT MATERIAL.
3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION
AND LANDSCAPING.
4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING
PARKWAYS AND MEDIANS, SHALL BE THOROUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE
SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL
AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE
SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET
FORTH IN SECTION 12-132.
5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK
ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF
CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY
BUILDING IN SUCH PHASE.
6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE
PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND
SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS,
WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION.
7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS.
8. THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES:
40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS
15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS
10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES
6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES.
4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES
4 FEET BETWEEN TREES AND GAS LINES
9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a).
10. PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE
ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST
BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN.
11. THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT
IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN.
12. MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND
DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST, SPECIES AND QUANTITIES
ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION.
13. ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES.
Street Tree Notes
1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY.
THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE
TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A
HOLD ON CERTIFICATE OF OCCUPANCY.
2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE
LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE.
3. STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE
PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED
LANDSCAPE CONTRACTOR.
4. THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY
DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE.
5. SUBJECT TO APPROVAL BY THE CITY FORESTER -- STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES,
STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A
REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS.
Grass Seed Mix
NON IRRIGATED NATIVE GRASS -
NATIVE GRASS - CITY OF FORT COLLINS NATIVE PRAIRIE SEED MIX
1. SEED SHALL BE AS MANUFACTURED BY ARKANSAS VALLEY SEED SOLUTIONS, 4625 COLORADO BOULEVARD,
DENVER, CO 80216, (877) 957-3337 OR APPROVED EQUAL. APPROVAL MUST BE PROVIDED BY CITY
ENVIRONMENTAL PLANNER. SEED SHALL CONTAIN NAME; LOT NUMBER; NET WEIGHT; AND PERCENTAGES OF
PURITY, GERMINATION, HARD SEED, AND MAXIMUM WEED SEED CONTENT CLEARLY MARKED.
2. SEED SHALL BE A MIXTURE THAT MATCHES THE FOLLOWING:
SCIENTIFIC NAME (VAR.) COMMON NAME PLS LBS./ACRE*
GRASSES
ARISTIDA PURPUREA PURPLE THREE-AWN 2
BUCHLOE DACTYLOIDES BUFFALOGRASS 8
CHONDROSUM GRACILE BLUE GRAMA 3
ELYMUS ELYMOIDES SQUIRRELTAIL 2
PASCOPYRUM SMITHII (ARRIBA) WESTERN WHEATGRASS 6
POA SECUNDA SANDBERG BLUEGRASS 1/2
STIPA COMATE NEEDLE AND THREAD 4
SUBTOTAL 25 ½
FORBES
ASTERMISIA FRIGIDA FRINGED SAGE 1/16
COREOPSIS TINCTORIA PLAINS COREOPSIS 1/16
ERYSIMUM ASPERMUM PLAINS WALLFLOWER 1/8
GAILARDIA PULCHELLA BLANKET FLOWER 1/2
LIATRIS PUNCTATE DOTTED GAYFEATHER 1/2
PENSTEMON ANGUSTIFOLIUS NARROWLEAF PENSTEMON 1/2
RATIBIDA COLUMNIFERA PRAIRIE CONEFLOWER 1/8
RUDBECKIA HIRTA GLORIOSA DAISY 1/16
SPHAERALCEA COCCINIA SCARLET GLOBEMALLOW 1/16
SUBTOTAL 2
TOTAL 27 ½
3. DRILL SEED APPLICATION RECOMMENDED PER SPECIFIED APPLICATION RATE TO NO MORE THAN 1 INCH DEPTH.
FOR BROADCAST SEEDING INSTEAD OF DRILL SEEDING METHOD - DOUBLE SPECIFICIED APPLICATION RATE
ABOVE AND HAND RAKE INTO SOIL TO NO MORE THAN 1 INCH DEPTH.
NON IRRIGATED NATIVE GRASS (CONT.) -
4. ADEQUATE TEMPORARY IRRIGATION OR BY WATER TRUCK WILL BE PROVIDED BY CONTRACTOR FOR THE ESTABLISHMENT
AND MAINTENANCE OF THESE SEEDED AREAS, AND THAT NATIVE GRASSES SHALL BE MAINTAINED IN A CONDITION OF
ACCEPTABLE, COVERAGE, HEIGHT, FREE OF WEEDS, TRASH AND DEBRIS, AND SHALL NOT BECOME A NUISANCE SITE FOR
WATER OR WIND EROSION NOR REPRESENT A FIRE HAZARD.
5. TREAT AREA PRIOR TO INSTALLATION OF SEED WITH APPROPRIATE HERBICIDE TO HELP CONTROL HERBACEOUS WEED
SPECIES. ONLY AFTER APPROPRIATE TIME PERIOD THEN APPLY NATIVE GRASS AND FORB SEED AS CALLED FOR ON
APPROVED PLANS.
6. INSTALL NATIVE GRASS AND FORB SEED MIX AT APPROPRIATE TIME IN SPRING OR FALL.
7. NATIVE GRASS AND FORB SEED MIX AREA INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. MOWING SHOULD ONLY
OCCUR IF AND WHEN PHYSICAL METHODS OF WEED MANAGEMENT ARE NECESSARY. IF AND WHEN MOWING OCCURS IN
NATIVE GRASS AND FORB SEED MIX AREAS DO NOT MOW LOWER THAN 6 INCHES IN HEIGHT TO AVOID INHIBITING NATIVE
PLANT GROWTH.
MULCH IN ALL NATIVE SEED AREAS:
1. IMMEDIATELY FOLLOWING THE RAKING / SEEDING OPERATION, ADD STRAW MULCH TO THE SEEDED AREAS.
2. APPLY STRAW MULCH AT A MINIMUM OF 1.5 TONS PER ACRE OF AIR DRY MATERIAL. SPREAD STRAW MULCH UNIFORMLY
OVER THE AREA WITH MECHANICAL MULCH SPREADER / CRIMPER. DO NOT MULCH WHEN WIND VELOCITY EXCEEDS 10 MPH.
3. WHEREVER THE USE OF CRIMPING EQUIPMENT IS PRACTICAL, PLACE MULCH IN THE MANNER NOTED ABOVE AND ANCHOR IT
INTO THE SOIL. USE A DISC SUCH AS A MULCH TILLER, WITH A FLAT SERRATED DISC AT LEAS ¼ INCH IN THICKNESS, HAVING
DULL EDGES, AND SPACE NO MORE THAN 9 INCHES APART, WITH DISCS OF SUFFICIENT DIAMETER TO PREVENT THE FRAME
OF THE EQUIPMENT FROM DRAGGING THE MULCH. ANCHOR MULCH A MINIMUM DEPTH OF 2 INCHES AND ACROSS THE
SLOPE WHERE PRACTICAL WITH NO MORE THAN TWO PASSES OF THE ANCHORING EQUIPMENT.
4. IMMEDIATELY UPON COMPLETION OF THE MULCHING AND BINDING OPERATION, THE SEEDED AREAS SHALL BE IRRIGATED,
KEEPING THE TOP 2 INCHES OF SOIL EVENLY MOIST UNTIL SEED HAS UNIFORMLY GERMINATED AND GROWN TO A HEIGHT OF
2-INCHES.
5. WATERING APPLICATION SHALL BE DONE IN A MANNER WHICH WILL PROVIDE UNIFORM COVERAGE BUT WHICH WILL NOT
CAUSE EROSION, MOVEMENT, OR DAMAGE TO THE FINISHED SURFACE.
Plant List
CAF
HSD
JSC
KENTUCKY BLUEGRASS
IRRIGATED TURF
CEDAR WOOD MULCH
WOOD MULCH
STEEL EDGER
2
LANDSCAPE PLAN
Plant List
Landscape Plan
A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC
RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND
SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO
RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY.
PROPOSED
BUILDING
SCALE 1" = 20'-0"
0 20' 30' 40'
NORTH
Sheet Number:
Fort Collins, CO
Boardwalk Office
Building
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Behtroud,CO 80513
TEL
WEB
970.532.5891
TBGroup.us
PROJECT TITLE
REVISIONS
ISSUE DATE
SHEET TITLE
SHEET INFORMATION
DATE
SEAL
August 22, 2017
DATE
PREPARED FOR
r4 Architects
226 Remington Street
Suite 3
Fort Collins CO 80524
Staff Comments 10.17.17
Parking Lot Interior Landscape
TOTAL PARKING AREA : 11,947 SQ FT
TOTAL LANDSCAPE AREA 875 SQ FT
LANDSCAPE PERCENTAGE 7.3%
Legend
SIGN
STREET LIGHT
STREET LIGHT
STREET LIGHT
SIGN
Hydrozone Table
ZONE AREA WATER USE GALLONS
HIGH 5,610 SF 18 GAL/SF 100,980 GAL
MODERATE 0 SF 10 GAL/SF 0 GAL
LOW 2,684 SF 3 GAL/SF 8,052 GAL
VERY LOW X SF 0 GAL/SF 0 GAL
TOTAL / AVERAGE 8,294 SF 109,032 GAL 13.1 GAL/SF
SPK -3
JSM - 2
GTI - 1
HSD - 22
JSC - 4
CAF - 7
HSD - 11
HSD - 8
BGA - 5
JSC - 1
BGA - 5
SPK - 3
BGA - 7
GTI - 1
CAF - 8
HSD - 13
SPK - 3
MRR - 1
SPK - 3
MRR - 1
HSD - 5
SPK - 3
CAF - 5
EAC - 7
CCM - 1
JSM - 3
CCM - 1
CAF - 5
UAC - 1
HSD - 8
JSC - 1
EAC - 1
BGA - 6
CAF - 3
EAC - 1
JSC - 1
HSD - 7
MRR - 1
CAF - 3
HSD - 2
MRR - 2
UAC - 1
CAF - 12
HSD - 9
CAF - 4
JSM - 3
CAF - 11
CCM - 1
JSM - 3
CAF - 4
HSD - 3
CAF - 3
HSD - 2
MRR - 1
CCM - 1
CAF - 3
SPK - 3
JSC - 1
EAC - 5
CAF - 8
JSC - 1
CAF - 14
CCM - 5
CAF - 14
CAF - 4
CCM - 3
CAF - 4
CAF - 2
JSC - 2
CAF - 2
GTI - 1
TAN - 1
GTI - 1
TAN - 1