Loading...
HomeMy WebLinkAboutFTC SKIBOS SC, WTF (VERIZON) - PDP - PDP170039 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSFTC SKIBOS SC 1010 N. COLLEGE AVE. FT. COLLINS, COLORADO 80524 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: FROM SOUTH VAUGHN WAY, MERGE ONTO I-225 N. TAKE EXIT 12A TO MERGE ONTO I-70 W. KEEP RIGHT AT THE FORK TO CONTINUE ON I-270 W. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARD FORT COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 WEST/EAST MULBERRY STREET TOWARD FORT COLLINS. TURN RIGHT ONTO RIVERSIDE AVE. CONTINUE ONTO JEFFERSON ST. TURN RIGHT ONTO NORTH COLLEGE AVE. SITE WILL BE ON YOUR RIGHT. FT. COLLINS, COLORADO CLIENT PROPERTY OWNER JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PHONE: 913-344-2030 SCREAMING EAGLE PROPERTIES CONTACT: MARK PRALL PHONE:970-988-7810 1108 N COLLGE AVE FT. COLLINS, CO 80524 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT STREET, UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (w/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: REVISION SCHEDULE REV A DATE 05-25-17 BY KRC PRELIMINARY ZDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC SKIBOS SC SITE ADDRESS: 1010 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0098 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-19-17 KRC PRELIMINARY ZDs C 07-17-17 KRC REVISED ZDs 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 D 09-22-17 GAC REVISED ZDs - NEW POLE PHOTOSIMULATION VIEWS PH-1 2 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING EAST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST) N.T.S. EM ET GM ET ET E EM GM 25'-0" SETBACK THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 Z-1 SITE PLAN SCALE: 1"=30'-0" EXISTING BUILDING PROPOSED FIBER RUN TO NEW EQUIPMENT CABINET 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE 15 0 7.5 15 30 60 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 05-25-17 BY KRC PRELIMINARY ZDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC SKIBOS SC SITE ADDRESS: 1010 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0098 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-19-17 KRC PRELIMINARY ZDs C 07-17-17 KRC REVISED ZDs ET ET UE UE UE UE UE UE UE UE UE UE UE UE UE F F F F F 10'-0" 12'-0" F F F F F F F F F F F F F F F F F GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 06/18/17. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2012 REQUIREMENTS. 15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-2 ENLARGED SITE PLAN SCALE: 3/32"=1'-0" PROPOSED FIBER RUN ET ET UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE U E UE UE UE F F F F F F F F F F F F 12'-0" 10'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-3 EQUIPMENT PLAN SCALE: 3/16"=1'-0" EQUIPMENT PLAN EXISTING TRANSFORMER (TYP) REVISION SCHEDULE REV A DATE 05-25-17 BY KRC PRELIMINARY ZDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC SKIBOS SC SITE ADDRESS: 1010 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0098 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-19-17 KRC PRELIMINARY ZDs C 07-17-17 KRC REVISED ZDs 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 D 09-22-17 GAC REVISED ZDs - NEW POLE 0 1 2 4 8 (SCALE BASED ON 11"x17" SHEETS ONLY) 25'-0" 23'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 2 Z-4 PROPOSED EAST ELEVATION SCALE: 1/16"=1'-0" 1 Z-4 EXISTING EAST ELEVATION SCALE: 1/16"=1'-0" REVISION SCHEDULE REV A DATE 05-25-17 BY KRC PRELIMINARY ZDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC SKIBOS SC SITE ADDRESS: 1010 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0098 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-19-17 KRC PRELIMINARY ZDs C 07-17-17 KRC REVISED ZDs 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 D 09-22-17 GAC REVISED ZDs - NEW POLE EXISTING BILLBOARD 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS Z-4 6 EXISTING 25' LIGHT POLE EXISTING BUILDING GRADE 0'-0" AGL PROPOSED VERIZON RAD CENTER 23'-0" AGL TOP OF PROPOSED POLE 25'-0" AGL PROPOSED QUASI OMNI ANTENNA MOUNTED TO POLE (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 3/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 5 Z-3 PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED POWER (DESIGN TBD) EXISTING UNDERGROUND ELECTRIC PROPOSED 12'x10' LEASE AREA PROPOSED QUASI OMNI ANTENNA MOUNTED TO NEW ALL IN ONE POLE PROPOSED 10'-0" WIDE UTILITY EASEMENT PROPOSED 10'-0" WIDE ACCESS & UTILITY EASEMENT EXISTING BOLLARD (TYP) FROM VAULT TO NEW EQUIPMENT CABINET REVISION SCHEDULE REV A DATE 05-25-17 BY KRC PRELIMINARY ZDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC SKIBOS SC SITE ADDRESS: 1010 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0098 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-19-17 KRC PRELIMINARY ZDs C 07-17-17 KRC REVISED ZDs 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 D 09-22-17 GAC REVISED ZDs - NEW POLE 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 0 2 4 8 12 16 20 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 ENLARGED SITE PLAN Z-2 4 PROPOSED 2'x3' FIBER VAULT PROPOSED QUASI OMNI ANTENNA MOUNTED TO NEW ALL IN ONE POLE 2 Z-4 N PROPOSED 10' WIDE ACCESS/UTILITY EASEMENT PROPOSED 10'-0" X 12'-0" VERIZON LEASE AREA PROPOSED 20'-10" POLE PROPOSED 10' WIDE UTILITY EASEMENT PROPOSED POWER (DESIGN TBD) EXISTING UNDERGROUND ELECTRIC (TYP) 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 D 09-22-17 GAC REVISED ZDs - NEW POLE SITE PLAN Z-1 3 PROPOSED 2'x3' FIBER VAULT LONG LAT SITE COORDINATES 105° 04' 33.67" WEST (NAD 83) 40° 36' 03.46" NORTH (NAD83) COLLEGE AVENUE PROPOSED QUASI OMNI ANTENNA MOUNTED ON NEW ALL IN ONE POLE EXISTING BUILDING EXISTING BUILDING EXISTING CAR LOT EXISTING 12' SIGNAGE EXISTING LIGHTPOLE (TYP.) PROPOSED 10'-0" WIDE ACCESS/UTILITY EASEMENT PROPOSED 10'-0" X 12'-0" VERIZON LEASE AREA PROPOSED 10'-0" WIDE UTILITY EASEMENT LEGEND W W W SS SS SS F F F GAS GAS GAS GAS GAS OE OE UT UT X X X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD SD SD SD E E E UE UE UE OT OT OT EV D O O O O U/G U/G OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING C Z-2 1 Z-2 1 FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 ENLARGED SITE PLAN Z-3 PROJECT DESCRIPTION 1. INSTALL NEW ALL IN ONE SMALL CELL POLE. 2. INSTALL (2) NEW REMOTE RADIO HEADS WITHIN NEW POLE. 3. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN. 4. RUN FIBER TO PROPOSED EQUIPMENT. 5. INSTALL ASSOCIATED SERVICE EQUIPMENT WITHIN NEW POLE. 6. NEW COMMERCIAL POWER TO SITE. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: GC-GENERAL COMMERCIAL APN: 97114-05-001 PARCEL SIZE: 20,474 S.F. ELEVATION: 4971' (NAVD 88) STRUCTURE TYPE: NEW POLE STRUCTURE HEIGHT: 25'-0" ANTENNA RAD CENTER: 23'-0" APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 662211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV A DATE 05-25-17 BY KRC PRELIMINARY ZDs DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC SKIBOS SC SITE ADDRESS: 1010 N. COLLEGE AVE. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0098 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-19-17 KRC PRELIMINARY ZDs C 07-17-17 KRC REVISED ZDs 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 D 09-22-17 GAC REVISED ZDs - NEW POLE Z-4 ELEVATIONS EQUIPMENT PLAN LEGAL DESCRIPTION PARCEL 1: BEGINNING AT A POINT 360 FEET NORTH OF THE SW CORNER OF THE NW 1/4 OF THE SW 1/4 OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, AND CONSIDERING SAID SECTION LINE AS RUNNING DUE NORTH AND SOUTH; THENCE EAST 190 FEET; THENCE NORTH 60 FEET; THENCE WEST 190 FEET; THENCE SOUTH 60 FEET TO THE POINT OF BEGINNING; LESS THE WEST 40 FEET FOR STATE HIGHWAY. PH-1 PHOTOSIMULATION VIEW