HomeMy WebLinkAboutFTC SKIBOS SC, WTF (VERIZON) - PDP - PDP170039 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSFTC SKIBOS SC
1010 N. COLLEGE AVE.
FT. COLLINS, COLORADO 80524
SMALL CELL
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
DEPART 3131 S VAUGHN WAY, AURORA, CO 80014:
FROM SOUTH VAUGHN WAY, MERGE ONTO I-225 N. TAKE EXIT 12A TO MERGE ONTO I-70 W. KEEP
RIGHT AT THE FORK TO CONTINUE ON I-270 W. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARD FORT
COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 WEST/EAST MULBERRY STREET TOWARD FORT
COLLINS. TURN RIGHT ONTO RIVERSIDE AVE. CONTINUE ONTO JEFFERSON ST. TURN RIGHT ONTO
NORTH COLLEGE AVE. SITE WILL BE ON YOUR RIGHT.
FT. COLLINS, COLORADO
CLIENT
PROPERTY OWNER
JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 66211
PHONE: 913-344-2030
SCREAMING EAGLE PROPERTIES
CONTACT: MARK PRALL
PHONE:970-988-7810
1108 N COLLGE AVE
FT. COLLINS, CO 80524
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JASON SHELLEDY
PHONE: 970-646-1283
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
1196 GRANT STREET, UNIT 313
DENVER, CO 80203
CONTACT: RYAN SAGAR
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2015 (w/ LOCAL AMENDMENTS)
NEC 2017
NFPA-1 (2006)
U - UTILITY
IIB
BUILDING CODE:
ELECTRICAL CODE:
REVISION SCHEDULE
REV
A
DATE
05-25-17
BY
KRC PRELIMINARY ZDs
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC SKIBOS SC
SITE ADDRESS:
1010 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0098
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-19-17 KRC PRELIMINARY ZDs
C 07-17-17 KRC REVISED ZDs
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
D 09-22-17 GAC REVISED ZDs - NEW POLE
PHOTOSIMULATION
VIEWS
PH-1
2
2
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING EAST)
N.T.S.
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST)
N.T.S.
EM
ET
GM
ET
ET
E
EM
GM
25'-0" SETBACK
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
1
Z-1
SITE PLAN
SCALE: 1"=30'-0"
EXISTING
BUILDING
PROPOSED FIBER RUN TO
NEW EQUIPMENT CABINET
1 inch = 30ft.
( IN FEET )
GRAPHIC SCALE
15 0 7.5 15 30 60
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV
A
DATE
05-25-17
BY
KRC PRELIMINARY ZDs
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC SKIBOS SC
SITE ADDRESS:
1010 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0098
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-19-17 KRC PRELIMINARY ZDs
C 07-17-17 KRC REVISED ZDs
ET
ET
UE UE UE UE UE UE UE UE
UE UE UE UE UE
F F F F F
10'-0"
12'-0"
F F F F F F F F
F F F F
F F F
F F
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND
REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS
THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES.
3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY
CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF
WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE
CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE
IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR
ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY.
5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS,
EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE
INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT
THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL"
BY RLF CONSULTING, DATED 06/18/17.
8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF.
THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED.
9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS
REQUIRED).
11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE.
12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER.
13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR
TO INSTALLATION.
14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2012 REQUIREMENTS.
15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL.
16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO
EXCAVATING.
17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT
OWNERS REPRESENTATIVE.
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
1
Z-2
ENLARGED SITE PLAN
SCALE: 3/32"=1'-0"
PROPOSED FIBER RUN
ET
ET
UE UE UE
UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE
UE UE UE UE U
E UE
UE UE
F F F F F F F F F F F F
12'-0"
10'-0"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
1
Z-3
EQUIPMENT PLAN
SCALE: 3/16"=1'-0"
EQUIPMENT PLAN
EXISTING
TRANSFORMER (TYP)
REVISION SCHEDULE
REV
A
DATE
05-25-17
BY
KRC PRELIMINARY ZDs
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC SKIBOS SC
SITE ADDRESS:
1010 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0098
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-19-17 KRC PRELIMINARY ZDs
C 07-17-17 KRC REVISED ZDs
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
D 09-22-17 GAC REVISED ZDs - NEW POLE
0 1 2 4 8
(SCALE BASED ON 11"x17" SHEETS ONLY)
25'-0"
23'-0"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
2
Z-4
PROPOSED EAST ELEVATION
SCALE: 1/16"=1'-0"
1
Z-4
EXISTING EAST ELEVATION
SCALE: 1/16"=1'-0"
REVISION SCHEDULE
REV
A
DATE
05-25-17
BY
KRC PRELIMINARY ZDs
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC SKIBOS SC
SITE ADDRESS:
1010 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0098
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-19-17 KRC PRELIMINARY ZDs
C 07-17-17 KRC REVISED ZDs
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
D 09-22-17 GAC REVISED ZDs - NEW POLE
EXISTING
BILLBOARD
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
8 0 4 8 16 32
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ELEVATIONS
Z-4
6
EXISTING 25'
LIGHT POLE
EXISTING
BUILDING
GRADE
0'-0" AGL
PROPOSED VERIZON RAD CENTER
23'-0" AGL
TOP OF PROPOSED POLE
25'-0" AGL
PROPOSED QUASI OMNI
ANTENNA MOUNTED TO POLE
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
3/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1
5
Z-3
PROPOSED FIBER RUN FROM
FIBER VAULT TO EQUIPMENT SITE
PROPOSED POWER
(DESIGN TBD)
EXISTING UNDERGROUND
ELECTRIC
PROPOSED 12'x10' LEASE AREA
PROPOSED QUASI OMNI
ANTENNA MOUNTED TO NEW
ALL IN ONE POLE
PROPOSED 10'-0" WIDE
UTILITY EASEMENT
PROPOSED 10'-0" WIDE
ACCESS & UTILITY EASEMENT
EXISTING BOLLARD (TYP)
FROM VAULT TO NEW
EQUIPMENT CABINET
REVISION SCHEDULE
REV
A
DATE
05-25-17
BY
KRC PRELIMINARY ZDs
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC SKIBOS SC
SITE ADDRESS:
1010 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0098
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-19-17 KRC PRELIMINARY ZDs
C 07-17-17 KRC REVISED ZDs
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
D 09-22-17 GAC REVISED ZDs - NEW POLE
3/32 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
0 2 4 8 12 16 20
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
2
ENLARGED SITE PLAN
Z-2
4
PROPOSED 2'x3'
FIBER VAULT
PROPOSED QUASI OMNI ANTENNA
MOUNTED TO NEW ALL IN ONE POLE
2
Z-4
N
PROPOSED 10' WIDE
ACCESS/UTILITY EASEMENT
PROPOSED 10'-0" X 12'-0" VERIZON
LEASE AREA
PROPOSED 20'-10" POLE
PROPOSED 10' WIDE UTILITY
EASEMENT
PROPOSED POWER
(DESIGN TBD)
EXISTING UNDERGROUND
ELECTRIC (TYP)
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
D 09-22-17 GAC REVISED ZDs - NEW POLE
SITE PLAN
Z-1
3
PROPOSED 2'x3'
FIBER VAULT
LONG
LAT
SITE COORDINATES
105° 04' 33.67" WEST (NAD 83)
40° 36' 03.46" NORTH (NAD83)
COLLEGE AVENUE
PROPOSED QUASI OMNI
ANTENNA MOUNTED
ON NEW ALL IN ONE POLE
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
CAR LOT
EXISTING 12'
SIGNAGE
EXISTING
LIGHTPOLE
(TYP.)
PROPOSED 10'-0" WIDE
ACCESS/UTILITY EASEMENT
PROPOSED 10'-0" X 12'-0"
VERIZON LEASE AREA
PROPOSED 10'-0" WIDE
UTILITY EASEMENT
LEGEND
W W W
SS SS SS
F F F
GAS GAS GAS GAS GAS
OE OE
UT UT
X X X X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD SD SD SD
E E E
UE UE UE
OT OT OT
EV
D
O O O O
U/G U/G
OHW OHW
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
C
Z-2
1
Z-2
1
FIRE SAFETY CODE:
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 ENLARGED SITE PLAN
Z-3
PROJECT DESCRIPTION
1. INSTALL NEW ALL IN ONE SMALL CELL POLE.
2. INSTALL (2) NEW REMOTE RADIO HEADS WITHIN NEW POLE.
3. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN.
4. RUN FIBER TO PROPOSED EQUIPMENT.
5. INSTALL ASSOCIATED SERVICE EQUIPMENT WITHIN NEW POLE.
6. NEW COMMERCIAL POWER TO SITE.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
JURISDICTION: CITY OF FT. COLLINS
ZONING: GC-GENERAL COMMERCIAL
APN: 97114-05-001
PARCEL SIZE: 20,474 S.F.
ELEVATION: 4971' (NAVD 88)
STRUCTURE TYPE: NEW POLE
STRUCTURE HEIGHT: 25'-0"
ANTENNA RAD CENTER: 23'-0"
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: JENNIFER SCHNEIDER
10740 NALL AVENUE, SUITE 400
OVERLAND PARK, KS 662211
PH: 913-344-2030
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: 720 279-8973
REVISION SCHEDULE
REV
A
DATE
05-25-17
BY
KRC PRELIMINARY ZDs
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 6
SITE NAME:
FTC SKIBOS SC
SITE ADDRESS:
1010 N. COLLEGE AVE.
FORT COLLINS, CO
80524
JURISDICTION:
CITY OF FT COLLINS
AERO PROJECT #: 097-17-0098
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
B 06-19-17 KRC PRELIMINARY ZDs
C 07-17-17 KRC REVISED ZDs
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
D 09-22-17 GAC REVISED ZDs - NEW POLE
Z-4 ELEVATIONS
EQUIPMENT PLAN
LEGAL DESCRIPTION
PARCEL 1:
BEGINNING AT A POINT 360 FEET NORTH OF THE SW CORNER OF THE NW 1/4 OF THE SW 1/4 OF
SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS,
COUNTY OF LARIMER, STATE OF COLORADO, AND CONSIDERING SAID SECTION LINE AS RUNNING
DUE NORTH AND SOUTH; THENCE EAST 190 FEET; THENCE NORTH 60 FEET; THENCE WEST 190
FEET; THENCE SOUTH 60 FEET TO THE POINT OF BEGINNING; LESS THE WEST 40 FEET FOR STATE
HIGHWAY.
PH-1 PHOTOSIMULATION VIEW