HomeMy WebLinkAboutHANSEN FARM - PDP - PDP170036 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSS. TIMBERLINE DRIVE RD. KECHTER RD ZEPHRY RD. CS1 COVER SHEET 1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEPTEMBER 2017 PROJECT LOCATION VICINITY MAP NORTH I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: Northern Engineering Services, Inc. Project No. HNP Date: March 1, 2004 Additional Field Survey: Project No. 911-015 Date: May 10, 2017 ORIGINAL FIELD SURVEY BY: CONTACT INFORMATION PROJECT TEAM: Danny Weber, PE Northern Engineering Services, Inc. 301 North Howes Street, Sutie 100 Fort Collins, Colorado 80521 (970) 221-4158 Bob Tessely, PLS Northern Engineering Services, Inc. 301 North Howes Street, Sutie 100 Fort Collins, Colorado 80521 (970) 221-4158 CONTACT INFORMATION PROJECT TEAM: Jeff Mark Lorson South Land Corp A. GENERAL NOTES 1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Preliminary Drainage and Erosion Control Report for Hansen Property dated September 12, 2017 by Northern Engineering Services, Inc., shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction 9' UTIL. 59' ROW ESMT. 4.5' WALK 9' UTIL. ESMT. 4.5' WALK LOCAL CONNECTOR STREET SECTION 8' PARKING 8' PARKING 10' TRAVEL LANE 7' PKWY 36' - 7' PKWY 10' TRAVEL LANE 57.5' HALF ROW 15' UTIL. ESMT. 2-LANE ARTERIAL- INTERIM STREET SECTION 6' BIKE LANE 8' BIKE LANE 58.5' -EOA 6' PKWY 8.5' GORE AREA PRIVATE STREET SECTION 12' TRAVEL LANE 24' - 12' TRAVEL LANE SECTION LINE 4-LANE ARTERIAL- ULTIMATE STREET SECTION 115' ROW (MIN.) 83' ROADWAY 15' Esmt. Util. Util. Esmt. 15' 12' TRAVEL LANE 12' TRAVEL LANE 12' TRAVEL LANE 12' TRAVEL LANE 8' BIKE LANE 6' PKWY 10' PKWY 6' WALK (MIN.) 10' TRAIL 19' CENTER MEDIAN 8' BIKE LANE 12' TRAVEL LANE 12' LEFT TURN LANE 12' TRAVEL LANE 10' TRAIL 12' LEFT TURN 9' UTIL. 76' ROW X X B M 12" W 12" W X ST VAULT F.O. T ELEC ELEC GAS VAULT F.O. VAULT ELEC VAULT ELEC TRAFFIC VAULT C VAULT F.O. VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC ELEC ELEC T VAULT F.O. B M X X TELE X X X X X X X X X X X X X X M F.O. MM GAS X X B M 12" W 12" W X VAULT F.O. T ELEC ELEC GAS VAULT F.O. VAULT ELEC VAULT ELEC TRAFFIC VAULT C VAULT F.O. VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC ELEC ELEC T VAULT F.O. B M X X TELE X X X X X X X X X X X X X X M F.O. MM GAS M F.O. X X X X X X X X X X X X X X X X X X X X X X X X SSMH 4-11 SSMH 15 SSMH 4-10 SSMH 14 SSMH 4-9 SSMH 13 SSMH 4-8 SSMH 4-7 SSMH 4-6 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 9' UTILITY EASEMENT STREET A STREET B STREET A STREET B 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' UE 3' DRAINAGE EASEMENT (TYP.) LOT 37 LOT 36 LOT 38 LOT 39 LOT 40 LOT 33 LOT 34 LOT 35 LOT 32 LOT 31 LOT 27 LOT 30 LOT 29 E E CTV CTV CTV VAULT ELEC TRAFFIC VAULT C ST TELE X X X X X X X X X M F.O. MM X 16" W SSMH 4-4 SSMH 4-5 INLET E1 CLEANOUT E2 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER LOT 39 LOT 43 LOT 40 LOT 42 LOT 44 LOT 45 LOT 41 LOT 52 LOT 46 LOT 47 LOT 48 LOT 49 LOT 50 LOT 51 LOT 53 LOT 54 END HORZ. DEFLECTION N:101534.65 E:204707.98 BEGIN HORZ. DEFLECTION N:101522.80 E:204735.46 8"x6" SWIVEL TEE 1 - 6" GV (N) N:101660.94 E:204451.19 FH ASSEMBLY N:101671.90 E:204456.58 286.17 LF 8" PVC N63°48'45"W SSMH 12 SSMH 11 SSMH 11-1 SSMH 10 SSMH 9 INLET F1 FES F CLEANOUT F2 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER LOT 10 LOT 9 LOT 8 LOT 3 LOT 7 LOT 5 LOT 4 LOT 2 LOT 1 LOT 19 LOT 18 LOT 17 LOT 16 LOT 12 LOT 14 LOT 13 LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 5 LOT 6 TRACT F LOT 6 LOT 15 ALLEY 8"x6" SWIVEL TEE 1 - 6" GV (SW) N:101149.82 E:203995.57 FH ASSEMBLY N:101140.86 E:203987.28 BEGIN HORZ. DEFLECTION N:101686.80 E:203390.56 END HORZ. DEFLECTION N:101588.48 E:203521.79 8"x8" CROSS w/TB 4 - 8" GV (NE,NW,SE,SW) N:101510.58 E:203605.94 8"x6" SWIVEL TEE E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV V AULT F.O. TELE ST M X GAS M F.O. 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W SSMH 7 SSMH 6 SSMH 8 SSMH 5 SSMH 4-4 SSMH 3 SSMH 4-3 SSMH 4-1 SSMH 4 SSMH 4-2 STMH A7 STMH A6 STMH A5 STMH A3-2 STMH A8 STMH A2 E E E E E E E E E E E E 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 16" W CTV CTV CTV CTV GG X X X SS ST VAULT F.O. T ELEC ELEC GAS VAULT F.O. VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC ELEC ELEC T VAULT F.O. B M X X X X X X X B M 12" W 12" W X VAULT F.O. T ELEC ELEC GAS VAULT F.O. VAULT ELEC VAULT ELEC TRAFFIC VAULT C VAULT F.O. VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC ELEC ELEC T VAULT F.O. B M X X TELE X X X X X X X X X X X X X X M F.O. MM GAS M F.O. X X X X X X X X X X X X X X X X X X X X X X X X 9' UTILITY EASEMENT STREET A STREET B STREET A STREET B 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' UE 3' DRAINAGE EASEMENT (TYP.) ALLEY ALLEY 59' ROW 36' FL-FL 24' FL-FL 10' CONCRETE TRAIL 10' CONCRETE TRAIL 6' UE 3' DRAINAGE EASEMENT (TYP.) STREET A 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT STREET C 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 36' FL-FL 59' ROW 9' UTILITY EASEMENT 9' UTILITY EASEMENT E E CTV CTV CTV VAULT ELEC TRAFFIC VAULT C ST TELE X X X X X X X X X M F.O. MM X TIMBERLINE RD STREET A 10' CONCRETE TRAIL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 36' FL-FL 59' ROW 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) 10' CONCRETE TRAIL 100' ROW TRACT A LOT 41 LOT 52 LOT 46 LOT 47 LOT 48 LOT 49 LOT 50 LOT 51 LOT 53 LOT 54 LOT 39 LOT 43 LOT 40 LOT 42 LOT 44 LOT 45 LOT 29 LOT 27 LOT 35 LOT 34 LOT 32 ALLEY 9' UTILITY EASEMENT 9' UTILITY EASEMENT 24' FL-FL 36' FL-FL 59' ROW 9' UTILITY EASEMENT 9' UTILITY EASEMENT 59' ROW 36' FL-FL 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) STREET B STREET B STREET C STREET C 9' UTILITY EASEMENT 9' UTILITY EASEMENT STORM DRAIN F LOT 6 TRACT F LOT 6 LOT 15 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 7 LOT 6 LOT 5 LOT 7 LOT 6 LOT 5 LOT 1 LOT 2 LOT 3 LOT 21 LOT 18 LOT 13 LOT 22 LOT 20 LOT 10 LOT 9 LOT 8 E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV V AULT F.O. TELE ST M X GAS M F.O. 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT TIMBERLINE RD TIMBERLINE RD 59' ROW 36' FL-FL 36' FL-FL 59' ROW 59' ROW 36' FL-FL STREET A STREET A 6' UE E E E E E E E E E E E E 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W CTV CTV CTV CTV FO FO GG X X X SS ST VAULT F.O. T ELEC ELEC GAS VAULT F.O. VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC ELEC ELEC T VAULT F.O. B M X X X X ∆ LOT 7 LOT 6 LOT 5 LOT 24 LOT 26 LOT 22 LOT 23 LOT 25 STA. = 10+00.00 (STREET A) STA. = 10+00.00 (STREET B) LOT 2 LOT 3 LOT 1 BLOCK 10 BLOCK 9 BLOCK 2 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT STREET A STREET B 59' ROW 36' FL-FL ALLEY TRACT G 4.5' SIDEWALK 4.5' SIDEWALK 4960 4965 4970 4975 4980 4960 4965 4970 4975 4980 9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 -0.70% PVI STA = 10+00.00 PVI ELEV = 4970.77 EXISTING GROUND PROPOSED GRADE 4970.77 4970.59 4970.42 4970.24 4970.07 4969.89 4969.72 4969.54 4969.37 4969.19 4969.02 4968.84 4968.67 ∆ LOT 4 LOT 3 TRACT G LOT 5 LOT 4 LOT 1 LOT 2 LOT 3 LOT 5 LOT 6 LOT 7 LOT 29 LOT 23 LOT 24 LOT 25 LOT 26 LOT 27 LOT 32 LOT 33 LOT 31 LOT 30 LOT 28 TRACT A LOT 41 TRACT F LOT 36 LOT 37 LOT 38 LOT 39 LOT 43 LOT 40 LOT 42 LOT 33 LOT 34 LOT 35 LOT 32 BLOCK 3 BLOCK 2 BLOCK 2 STREET C SEE SHT R8 STREET A BLOCK 14 9' UTILITY EASEMENT 36' FL-FL 59' ROW 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT STA. = 18+43.54 (STREET A) STA. = 10+00.00 (STREET C) R20' R20' 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 36' FL-FL 59' ROW DRIVE-OVER CURB & GUTTER DRIVE-OVER CURB & GUTTER 4955 4960 4965 4970 ∆ LOT 42 LOT 34 LOT 35 LOT 32 LOT 33 LOT 31 LOT 45 LOT 44 LOT 43 LOT 38 LOT 40 LOT 41 LOT 36 LOT 39 LOT 37 LOT 46 LOT 47 LOT 48 LOT 49 LOT 50 LOT 51 LOT 52 LOT 56 LOT 53 LOT 54 LOT 55 LOT 57 LOT 43 LOT 44 LOT 45 STREET A 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 10' CONCRETE PAN BLOCK 2 BLOCK 3 BLOCK 3 BLOCK 2 TRACT A TRACT F 2' SIDEWALK CHASE 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 59' ROW 36' FL-FL DRIVE-OVER CURB & GUTTER DRIVE-OVER CURB & GUTTER 4955 4960 4965 4970 4975 4955 4960 4965 4970 4975 23+50 24+00 25+00 26+00 27+00 28+00 29+00 30+00 30+50 2.00% 0.50% -0.60% -2.00% -0.60% PVI STA = 25+03.97 ∆ LOT 45 LOT 57 LOT 58 TRACT E TRACT B TRACT D STREET A 9' UTILITY EASEMENT 4.5' SIDEWALK STREET D SEE SHT R9 STREET B SEE SHT R7 9' UTILITY EASEMENT 4.5' SIDEWALK STA. = 31+65.81 (STREET A) STA. = 10+00.00 (STREET D) STA. = 36+19.31 (STREET A) STA. = 37+84.82 (STREET B) R20' R20' R20' R20' STORM DRAIN B STORM DRAIN C STORM DRAIN A STREET A ZEPHYR ROAD SEE SHT R10 SIGHT DISTANCE EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 36' FL-FL 59' ROW VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER 4950 4955 4960 4965 4970 4950 4955 4960 4965 4970 30+50 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 39+00 40+00 40+50 1.50% ∆ LOT 4 LOT 7 LOT 6 LOT 5 LOT 20 LOT 22 LOT 21 LOT 23 TRACT I 9' UTILITY EASEMENT 4.5' SIDEWALK STA. = 10+00.00 (STREET B) STA. = 10+00.00 (STREET A) STREET B ALLEY BLOCK 2 4960 4965 4970 4975 4980 4960 4965 4970 4975 4980 9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 18+50 0.60% -0.60% PVI STA = 10+00.00 PVI ELEV = 4970.77 75.0' VC HP ELEV = 4970.96 HP STA = 10+50.00 PVI STA = 10+50.00 PVI ELEV = 4971.07 BVCS: 10+12.50 BVCE: 4970.85 EVCS: 10+87.50 EVCE: 4970.85 A.D. = 1.20 K = 62.50 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE 4970.77 4970.77 4970.17 4969.57 4968.97 4968.37 4967.77 4967.17 ∆ LOT 3 LOT 5 LOT 4 LOT 2 LOT 1 LOT 6 LOT 19 LOT 18 LOT 17 LOT 16 LOT 14 LOT 12 LOT 13 LOT 11 LOT 10 LOT 9 TRACT F LOT 15 LOT 17 LOT 16 LOT 15 LOT 14 LOT 12 LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 13 9' UTILITY EASEMENT 4.5' SIDEWALK DRIVE-OVER CURB & GUTTER DRIVE-OVER CURB & GUTTER STREET B 9' UTILITY EASEMENT 4.5' SIDEWALK STREET B STREET C SEE SHT R8 STREET C SEE SHT R8 BLOCK 1 BLOCK 3 BLOCK 2 BLOCK 5 LOT 3 LOT 5 LOT 4 LOT 1 TRACT I TRACT F STA. = 22+14.93 (STREET B) STA. = 14+58.41 (STREET C) R20' R20' R20' R20' DRIVE-OVER CURB & GUTTER DRIVE-OVER CURB & GUTTER 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 59' ROW ∆ LOT 10 LOT 9 LOT 8 LOT 7 LOT 3 LOT 5 LOT 2 LOT 4 LOT 1 LOT 6 LOT 7 LOT 6 LOT 5 LOT 3 LOT 2 LOT 1 LOT 4 STREET B DRIVE-OVER CURB & GUTTER DRIVE-OVER CURB & GUTTER 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK STORM DRAIN A 36' FL-FL 59' ROW TRACT E TRACT B TRACT F BLOCK 1 BLOCK 3 4950 4955 4960 4965 4970 4950 4955 4960 4965 4970 28+50 29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 2.25% 0.60% -2.00% -0.60% -0.50% 0.50% PVI STA = 31+03.98 PVI ELEV = 4962.72 PVI STA = 34+77.45 PVI ELEV = 4962.29 PVI STA = 37+62.82 PVI ELEV = 4959.93 PVI STA = 37+68.82 PVI ELEV = 4959.93 PVI STA = 37+84.82 PVI ELEV = 4960.29 75.0' VC HP ELEV = 4963.51 ∆ STREET C STREET B SEE SHT R6 DRIVE-OVER CURB & GUTTER 9' UTILITY EASEMENT 4.5' SIDEWALK STOP SIGN w/ STREET NAME 9' UTILITY EASEMENT 4.5' SIDEWALK LOT 25 LOT 4 TRACT G LOT 3 LOT 7 LOT 6 LOT 5 LOT 1 LOT 2 LOT 21 LOT 18 LOT 22 LOT 17 LOT 19 LOT 20 LOT 23 LOT 24 LOT 2 LOT 1 LOT 4 LOT 5 LOT 3 DRIVE-OVER CURB & GUTTER STA. = 14+58.41 (STREET C) STA. = 22+14.93 (STREET B) STA. = 12+42.95 (STREET C) STA. = 19+08.87 (ALLEY) STA. = 10+00.00 (STREET C) STA. = 18+43.54 (STREET A) 10' CONCRETE PAN 2' SIDEWALK CHASE BLOCK 14 BLOCK 4 TRACT I TRACT F FUTURE STREET C STREET B SEE SHT R6 E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV M F.O. 16" W 16" W 16" W 16" W 16" W STREET D 9' UTILITY EASEMENT 4.5' SIDEWALK VERTICAL CURB & GUTTER STREET A SEE SHT R4 STA. = 10+00.00 (STREET D) STA. = 31+65.81 (STREET A) STREET A SEE SHT R4 STA. = 13+27.77 (STREET D) STA. = 17+45.85 (TIMBERLINE RD) 9' UTILITY EASEMENT 4.5' SIDEWALK VERTICAL CURB & GUTTER STORM DRAIN B STORM DRAIN A TIMBERLINE RD SEE SHT R14 TIMBERLINE RD SEE SHT R14 STOP SIGN w/ STREET NAME 36' FL-FL 59' ROW R20' R25' R25' R20' LOT 58 BLOCK 2 TRACT A TRACT D 4950 4955 9' UTILITY EASEMENT FUTURE ZEPHYR ROAD FUTURE 76' ROW FUTURE 50' FL-FL FUTURE VERTICAL CURB & GUTTER FUTURE VERTICAL CURB & GUTTER R40' R60' R20' 4945 4950 4955 4960 4965 4945 4950 4955 4960 4965 9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 4.00% -0.50% 0.50% PVI STA = 10+28.50 PVI ELEV = 4955.75 PVI STA = 12+77.50 PVI ELEV = 4954.50 BVCS: 17+12.85 BVCE: 4961.71 210.0' VC PVI STA = 15+69.12 PVI ELEV = 4955.96 BVCS: 14+64.12 BVCE: 4955.44 EVCS: 16+74.12 EVCE: 4960.16 A.D. = 3.50 K = 60.00 4955.64 4955.52 4955.39 4955.27 4955.14 4955.02 4954.89 4954.77 4954.64 4954.52 4954.62 4954.74 4954.87 4954.99 4955.12 4955.24 4955.37 X X X 9' UTILITY EASEMENT FUTURE ZEPHYR ROAD FUTURE VERTICAL CURB & GUTTER FUTURE VERTICAL CURB & GUTTER 9' UTILITY EASEMENT ROUNDABOUT DETAIL SEE SHEET HC1 4960 4965 4970 4975 4980 4960 4965 4970 4975 4980 18+00 19+00 20+00 21+00 21+50 4965.15 4965.63 4966.01 4966.28 4966.45 4966.51 4966.47 4966.33 4966.08 4965.73 PVI STA = 20+72.85 PVI ELEV = 4965.31 360.0' VC HP ELEV = 4966.51 HP STA = 19+52.85 PVI STA = 18+92.85 PVI ELEV = 4968.91 EVCS: 20+72.85 EVCE: 4965.31 A.D. = 6.00 K = 60.00 EXISTING GROUND FUTURE GRADE EXISTING GROUND FUTURE GRADE CTV CTV CTV CTV FO VAULT F.O. ST ST M MM X M 15' UTILITY EASEMENT TIMBERLINE ROAD 6' SIDEWALK STREET D SEE SHT R9 PROPOSED VERTICAL CURB & GUTTER EXISTING EDGE OF ASPHALT PROPOSED VERTICAL CURB & GUTTER STORM DRAIN A 108' ROW 59' FL-EOP STORM DRAIN H 15' UTILITY EASEMENT 10' SIDEWALK REMOVE AND MILL & OVERLAY REPLACE ASPHALT 69' FL-EOP 120' ROW STA. = 17+45.89 (TIMBERLINE ROAD) STA. = 13+26.75 (STREET D) PROPOSED ADDITIONAL ASPHALT MAIL CREEK DITCH 4955 4960 4965 4970 4975 4955 4960 4965 4970 4975 9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 4955 4960 4965 4970 4975 4955 4960 4965 4970 4975 9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 4955 4960 15' UTILITY EASEMENT TIMBERLINE ROAD 10' SIDEWALK PROPOSED VERTICAL CURB & GUTTER EXISTING CURB & GUTTER STORM DRAIN G STORM DRAIN A ZEPHYR ROAD SEE SHT R11 TIMBERLINE ROAD 119' ROW 95' FL-FL EXISTING EDGE OF ASPHALT PROPOSED VERTICAL CURB & GUTTER EXISTING CURB & GUTTER TIE TO EXISTING CURB & GUTTER 15' UTILITY EASEMENT FUTURE 6' SIDEWALK 108' ROW 128' ROW EXISTING CURB & GUTTER 95' FL-FL PROPOSED ADDITIONAL ASPHALT PROPOSED ADDITIONAL ASPHALT STA. = 26+15.85 (TIMBERLINE ROAD) STA. = 13+85.98 (ZEPHYR ROAD) REMOVE AND REPLACE ASPHALT 4955 4960 4965 4970 4975 4955 4960 4965 4970 4975 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 0.66% 500.0' VC HP ELEV = 4963.26 HP STA = 27+90.13 PVI STA = 28+51.78 PVI ELEV = 4964.45 BVCS: 25+51.78 BVCE: 4962.47 A.D. = 2.07 X IRR IRR TIMBERLINE ROAD EXISTING CURB & GUTTER EXISTING CURB & GUTTER 127' ROW 4945 4950 4955 4960 4965 4945 4950 4955 4960 4965 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 200.0' VC PVI STA = 33+13.62 PVI ELEV = 4957.33 BVCS: 32+13.62 BVCE: 4959.07 EVCS: 34+13.62 EVCE: 4954.65 A.D. = 0.95 K = 210.75 EVCS: 30+51.78 EVCE: 4961.62 -2.68% -1.41% -1.74% -2.37% PVI STA = 31+31.50 PVI ELEV = 4960.49 PVI STA = 36+03.77 PVI ELEV = 4949.54 PVI STA = 36+27.07 PVI ELEV = 4948.99 4960.94 4959.31 4957.39 4955.01 4952.33 4949.64 4961.98 4961.65 4961.29 4960.59 4960.17 4959.74 4958.87 4958.41 4957.91 4956.84 4956.26 4955.65 4954.34 M MM X M TIMBERLINE RD STREET D EX ~13' TRAVEL LANE PROPOSED 107.5' ROW PROPERTY BOUNDARY (TYP.) EX ~11' TWLTL LANE EX ~13' TRAVEL LANE EX ~6' BIKE LANE EX ~7' BIKE LANE 12' RIGHT-TURN LANE 12' TRAVEL LANE 8' BIKE LANE EXISTING 100.0' ROW EXISTING EDGE OF PAVEMENT EXISTING CURB AND GUTTER BEGIN PROPOSED RESTRIPING 235.0' DECEL AND BRAKING GORE AREA (WIDTH VARIES) EX ~6' BIKE LANE 200.0' BAY TAPER 8.5' SHOULDER PROPOSED 119.5' ROW 8' BIKE LANE 12' TRAVEL LANE 12' LEFT-TURN LANE EX ~12' TRAVEL LANE EX ~6.5' BIKE LANE END OF ULTIMATE IMPROVEMENTS FOR HALF RIGHT-OF-WAY FUTURE CURB AND GUTTER SHOULDER (WIDTH VARIES) PROPOSED 70.0' EOP-FL EX ~12' TRAVEL LANE PROPOSED 59.0' EOP-FL TIMBERLINE RD ZEPHYR RD 8.5' SHOULDER EX ~8' BIKE LANE EX ~12' LEFT-TURN LANE EX ~13' TRAVEL LANE EX ~7' BIKE LANE EX GORE AREA (WIDTH VARIES) EX ~13' TRAVEL LANE 200.0' BAY TAPER 235.0' DECEL AND BRAKING PROPOSED 119.5' ROW 12' RIGHT-TURN LANE EX RIGHT-TURN LANE ZEPHYR RD ZEPHYR RD PROPOSED 76.0' ROW 12' LEFT-TURN LANE 12' TRAVEL LANE 12' TRAVEL LANE 8' BIKE LANE 8' BIKE LANE TIMBERLINE RD ~11' TRAVEL LANE ~7' BIKE LANE EX ~12' LEFT-TURN LANE EX ~12' TRAVEL LANE EX ~7' BIKE LANE PROPOSED 50.0' FL-FL Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R16 STRIPING PLAN ZEPHYR ROAD 32 KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH LEGEND: PROPOSED CURB & GUTTER CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE ST X X X X X X X X X X X X X X X X X X X X X LOT 97 ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ ∆ R66' R60' R40' R20' N:100375.77 E:204864.41 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN ST X X X X X X X X X X X X X X X X X X X X X LOT 97 64.44 64.29 65.61 60.99 61.35 61.77 62.83 63.90 64.51 64.66 64.20 63.98 63.58 62.28 62.27 62.47 62.94 62.94 63.31 63.49 60.99 61.30 62.67 62.15 62.80 62.72 62.20 61.57 61.34 61.11 61.11 61.37 62.68 62.79 62.84 62.98 63.12 63.37 63.41 63.27 63.16 63.36 63.98 64.21 65.27 X VAULT F.O. VAULT F.O. VAULT F.O. VAULT F.O. B M X X X X X X X X M F.O. 2a 2c 2b 2g 2j 2h 2f 3 4 1a 1m 1l 1k 1b 3 4 2F 2J 2H 2G 2E 2B 2A 2C 1A 1M 1L 1J 2D 2d 2e DETENTION POND 2B 100-YR VOL=1.61 ac PEAK RELEASE=6.58 cfs 100-YR VOL=1.20 ac PEAK RELEASE=0.86 cfs DETENTION POND 3 100-YR VOL=0.81 ac PEAK RELEASE=1.10 cfs FUTURE DETENTION POND 4 100-YR VOL=0.79 ac PEAK RELEASE=0.59 cfs DETENTION POND 1 100-YR VOL=7.86 ac PEAK RELEASE=1.45 cfs NORTHEAST RAIN GARDEN X X B M C X X X X X X X X M F.O. MM 1k 1b 1d 1e 1H 2A 1K 1G 1F 1B 1C 1D 1E 2j 2h 2g 2f 1c DETENTION POND 2A 100-YR VOL=1.20 ac NORTHWEST RAIN GARDEN DR1 DRAINAGE EXHIBIT OVERALL 35 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD LEGEND: ST PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY A DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY B2 1.45 ac DESIGN POINT FLOW ARROWS 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR HANSEN PROPERTY" BY NORTHERN ENGINEERING, DATED SEPTEMBER 12, 2017 FOR ADDITIONAL INFORMATION. 3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. NOTES: BASIN DESIGNATION BASIN AREA (AC) ( IN FEET ) 0 1 INCH = 150 FEET 150 150 300 450 NORTH DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) 1a 1A 10.99 0.45 0.57 13.6 12.6 9.71 43.82 1b 1B 0.44 0.54 0.68 10.4 8.4 0.53 2.53 1c 1C 1.56 0.79 0.99 9.5 7.0 2.84 14.00 1d 1D 1.06 0.61 0.76 10.6 7.8 1.39 6.90 1e 1E 8.14 0.58 0.72 25.4 22.8 6.71 30.84 1f 1F 2.27 0.57 0.71 14.4 12.7 2.48 11.39 1g 1G 2.35 0.81 1.00 12.0 8.9 3.95 19.26 1h 1H 9.81 0.56 0.70 24.8 22.2 7.99 36.78 1j 1J 1.04 0.70 0.88 5.0 5.0 2.09 9.13 1k 1K 0.75 0.55 0.69 8.8 6.8 0.97 4.67 1l 1L 2.85 0.65 0.82 6.1 5.2 4.97 23.15 1m 1M 3.21 0.65 0.81 13.7 10.7 4.08 19.78 2a 2A 2.85 0.37 0.47 11.8 10.8 2.23 10.11 2b 2B 1.32 0.75 0.93 9.1 6.5 2.27 11.15 2c 2C 1.38 0.59 0.74 20.8 15.4 1.29 6.62 2d 2D 0.54 0.83 1.00 5.7 5.0 1.24 5.34 2e 2E 0.80 0.72 0.90 10.9 6.3 1.25 6.70 2f 2F 4.65 0.69 0.86 12.0 7.5 6.59 35.35 2g 2G 2.54 0.68 0.85 13.9 9.1 3.37 17.37 2h 2H 3.92 0.32 0.40 20.4 18.8 2.04 9.23 2j 2J 0.87 0.79 0.98 10.5 6.2 1.49 7.98 3 3 3.35 0.95 1.00 5.0 5.0 9.08 33.37 4 4 3.10 0.95 1.00 6.7 5.3 7.63 30.80 75% On-Site Treatment by LID Summary Table Basin(s) LID Treatment Totale Basin(s) Area (Ac.) Rain Garden Req'd Min. Volume (Cu.-Ft.) 1A Grass Buffer 10.99 1B, 1C, 1D, & 1E NE Rain Garden 11.23 6,278 1F, 1G, 1H, 1J, & 1K NW Rain Garden 16.22 9,087 1L & 1M Grass Buffer 6.06 2A Grass Buffer 2.85 2B, 2C, 2D, 2J None 4.11 2E, 2F, 2G, 2H Site Specific 11.91 3 Site Specific 3.35 4 Site Specific 3.10 Total Site Area 69.82 Areas Requiring Site Specific LID Treatment Multi-family lots (Tract D) 4.39 Acres Multi-family lots (Tract E) 5.29 Acres Local Commerical (Tract C) 4.85 Acres Neighborhood Park 3.92 Acres Total Newly Developed Area less Site Specific Areas 51.37 Acres Total Newly Developed Area Treated 47.35 Acres Percent of Newly Developed Area Treated 92.18% 65.20 2.1% 2.0% 2.0% 2.0% Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com INT1 INTERSECTION DETAILS 34 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH PHONE: 970.221.4158 www.northernengineering.com HC1 HORIZONTAL CONTROL PLAN 33 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH CROSSPAN (TYP.) RIGHT-OF-WAY SIGNAGE NOTES: LOT LINE 1. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE LCUASS STANDARDS. 2. STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS ON SAME POLE, PER LCUASS DRAWING 1401. 3. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE TOWN OF TIMNATH TRAFFIC ENGINEER. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. 4. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 5. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. 6. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW, PRIOR TO INITIATION OF THE WARRANTY PERIOD. THE CITY OF FORT COLLINS RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE TOWN OF TIMNATH DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). 7. THE LAYOUT OF ALL SIGNING AND STRIPING USING 3-M TEMPORARY TAPE AT A MINIMUM OF 50' SPACING SHALL BE APPROVED BY THE CITY STREET INSPECTOR PRIOR TO TH E INSTALLATION 8" SOLID WHITE LINE (2) 4" SOLID LINES; 4" APART DOUBLE YELLOW LINE DOUBLE YELLOW LINE 4" SOLID LINE, 4" DASHED LINE; 4" APART STRIPING LEGEND: PAVEMENT STRIPING AND MARKINGS: 4" SOLID WHITE LINE PREFORMED PLASTIC PAVEMENT MARKING BICYCLIST AND ARROW 1 3 4 5 A 2 8" DASHED WHITE EXTENSION LINE PREFORMED PLASTIC PAVEMENT MARKING 24" WIDE STOP BAR PREFORMED PLASTIC PAVEMENT MARKING RIGHT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING LEFT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING "ONLY" (22.5 S.F. EA.) C B D E 2" SEGMENTS, 4" APART 6 4" BROKEN WHITE LINE 7 4" SOLID YELLOW LINE F 18" x 9' CROSS-WALK 10' SEGMENTS, 30' GAPS EXISTING 49.4' FL-FL EXISTING 79.0'ROW (WIDTH VARIES) EX ~13' RIGHT-TURN LANE EX ~6' BIKE LANE EX ~13' TRAVEL LANE GORE AREA (WIDTH VARIES) 12' LEFT-TURN LANE EX ~12' TRAVEL LANE EX ~8' BIKE LANE PROPOSED 127.5' ROW PROPOSED 57.5' PROPOSED 69.5' HALF ROW HALF ROW 235.0' DECEL AND BRAKING 200.0' BAY TAPER 12" W 12" W X IRR IRR IRR EX GORE AREA (WIDTH VARIES) EX ~12' TRAVEL LANE EX ~8' BIKE LANE EX RIGHT-TURN LANE (WIDTH VARIES) EX ~13' TWLTL LANE 200.0' BAY TAPER ROSEN DR TIMBERLINE RD END PROPOSED RESTRIPING Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R15 STRIPING PLAN TIMBERLINE ROAD 31 KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH LEGEND: PROPOSED CURB & GUTTER CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) RIGHT-OF-WAY SIGNAGE NOTES: LOT LINE 1. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE LCUASS STANDARDS. 2. STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS ON SAME POLE, PER LCUASS DRAWING 1401. 3. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE TOWN OF TIMNATH TRAFFIC ENGINEER. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. 4. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 5. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. 6. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW, PRIOR TO INITIATION OF THE WARRANTY PERIOD. THE CITY OF FORT COLLINS RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE TOWN OF TIMNATH DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). 7. THE LAYOUT OF ALL SIGNING AND STRIPING USING 3-M TEMPORARY TAPE AT A MINIMUM OF 50' SPACING SHALL BE APPROVED BY THE CITY STREET INSPECTOR PRIOR TO TH E INSTALLATION 8" SOLID WHITE LINE (2) 4" SOLID LINES; 4" APART DOUBLE YELLOW LINE DOUBLE YELLOW LINE 4" SOLID LINE, 4" DASHED LINE; 4" APART STRIPING LEGEND: PAVEMENT STRIPING AND MARKINGS: 4" SOLID WHITE LINE PREFORMED PLASTIC PAVEMENT MARKING BICYCLIST AND ARROW 1 3 4 5 A 2 8" DASHED WHITE EXTENSION LINE PREFORMED PLASTIC PAVEMENT MARKING 24" WIDE STOP BAR PREFORMED PLASTIC PAVEMENT MARKING RIGHT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING LEFT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING "ONLY" (22.5 S.F. EA.) C B D E 2" SEGMENTS, 4" APART 6 4" BROKEN WHITE LINE 7 4" SOLID YELLOW LINE F 18" x 9' CROSS-WALK 10' SEGMENTS, 30' GAPS EXISTING 80.0' ROW 4953.67 4953.00 4951.66 4950.99 4950.32 4949.04 EXISTING GROUND EXISTING GROUND Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R14 PLAN AND PROFILE TIMBERLINE ROAD 30 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH LINE MATCH STA 30+00 SEE SHT R13 R14 R13 R12 CENTERLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R13 STA 30+00 K = 241.31 400.0' VC LP ELEV = 4960.42 LP STA = 21+48.82 PVI STA = 21+31.77 PVI ELEV = 4959.71 ECVS: 23+31.77 EVCE: 4961.02 A.D. = 1.44 K = 277.84 4955 4960 4965 4970 4975 4955 4960 4965 4970 4975 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 0.96% 0.50% 0.90% 0.59% -0.50% 0.58% 0.81% 0.96% PVI STA = 21+86.51 PVI ELEV = 4958.84 PVI STA = 23+26.58 PVI ELEV = 4959.54 PVI STA = 23+85.90 PVI ELEV = 4960.07 PVI STA = 25+11.06 PVI ELEV = 4960.81 PVI STA = 25+67.69 PVI ELEV = 4961.35 PVI STA = 26+65.20 PVI ELEV = 4961.92 PVI STA = 26+68.24 PVI ELEV = 4961.94 PVI STA = 27+13.38 PVI ELEV = 4962.37 4960.46 4960.47 4960.83 4961.47 4962.13 4962.76 4963.15 4963.26 4963.05 4960.70 4960.60 4960.52 4960.43 4960.42 4960.43 4960.53 4960.61 4960.71 4960.98 4961.14 4961.31 4961.64 4961.80 4961.97 4962.30 4962.46 4962.62 4962.88 4962.99 4963.07 4963.20 4963.24 4963.25 4963.24 4963.21 4963.15 4962.91 4962.74 4962.52 4959.64 4959.52 4959.39 4959.27 4959.14 4959.02 4958.89 4958.90 4959.03 4959.15 4959.28 4959.40 4959.53 4959.75 4959.97 4960.15 4960.30 4960.45 4960.60 4960.74 4960.94 4961.18 4961.40 4961.54 4961.68 4961.83 4962.00 4962.24 EXISTING GROUND EXISTING GROUND EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE TIE TO EXISTING CURB & GUTTER Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R13 PLAN AND PROFILE TIMBERLINE ROAD 29 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH LINE MATCH STA 30+00 SEE SHT R14 R14 R13 R12 CENTERLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R14 STA 30+00 MATCH LINE SEE SHEET R12 STA 20+00 MATCH LINE SEE SHEET R12 STA 20+00 LINE MATCH STA 20+00 S EE SHT R12 4965 4970 4975 4955 4960 4965 4970 4975 9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 0.70% -0.78% 0.91% PVI STA = 10+00.00 PVI ELEV = 4960.05 PVI STA = 10+69.85 PVI ELEV = 4960.54 300.0' VC HP ELEV = 4964.01 HP STA = 14+92.18 PVI STA = 15+11.56 PVI ELEV = 4964.55 BVCS: 14+11.56 BVCE: 4963.64 EVCS: 17+11.56 EVCE: 4962.99 A.D. = 1.69 K = 177.61 BCVS: 19+31.77 BVCE: 4961.27 0.72% -0.90% -0.30% -0.83% -0.50% -0.90% 0.92% 0.90% PVI STA = 10+00.00 PVI ELEV = 4959.23 PVI STA = 10+70.21 PVI ELEV = 4959.74 PVI STA = 13+00.00 PVI ELEV = 4961.85 PVI STA = 17+03.30 PVI ELEV = 4961.40 PVI STA = 17+86.46 PVI ELEV = 4961.15 PVI STA = 17+90.00 PVI ELEV = 4961.12 PVI STA = 18+66.44 PVI ELEV = 4960.44 198.0' VC HP ELEV = 4963.00 HP STA = 14+76.73 PVI STA = 14+76.73 PVI ELEV = 4963.44 BVCS: 13+77.73 BVCE: 4962.55 EVCS: 15+75.73 EVCE: 4962.55 A.D. = 1.80 K = 110.00 -0.50% -0.54% 0.70% PVI STA = 13+69.09 PVI ELEV = 4963.05 PVI STA = 16+97.62 PVI ELEV = 4962.83 PVI STA = 17+11.64 PVI ELEV = 4962.75 132.3' VC HP ELEV = 4963.69 HP STA = 14+98.34 PVI STA = 14+87.18 PVI ELEV = 4963.88 BVCS: 14+21.01 BVCE: 4963.42 EVCS: 15+53.34 EVCE: 4963.55 A.D. = 1.20 K = 110.00 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE 4963.09 4963.27 4963.45 4963.58 4963.67 4963.69 4963.66 4963.57 4963.44 4963.32 4963.19 4963.07 4962.94 4962.82 4960.05 4960.23 4960.40 4960.59 4960.82 4961.04 4961.27 4961.50 4961.72 4961.95 4962.18 4962.40 4962.63 4962.86 4963.09 4963.31 4963.54 4963.76 4963.91 4963.99 4964.01 4963.96 4963.88 4963.79 4963.69 4963.56 4963.42 4963.26 4963.08 4962.88 4962.69 4962.49 4962.30 4962.10 4961.91 4961.71 4961.52 4961.32 4961.13 4960.97 4959.23 4959.41 4959.59 4959.78 4960.01 4960.24 4960.47 4960.70 4960.93 4961.16 4961.39 4961.62 4961.85 4962.08 4962.30 4962.53 4962.73 4962.88 4962.96 4963.00 4962.97 4962.89 4962.75 4962.56 4962.33 4962.11 4961.88 4961.66 4961.43 4961.34 4961.26 4961.19 4961.03 4960.81 4960.58 4960.39 4960.27 4960.14 4960.02 4959.89 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE STA.=13+79.96 ELEV.= 4963.36 BEGIN MILL & OVERLAY STA.=17+02.87 ELEV.= 4963.06 END MILL & OVERLAY Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R12 PLAN AND PROFILE TIMBERLINE ROAD 28 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH LEFT FLOWLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 20+00 SEE SHT R13 R14 R13 R12 CENTERLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R13 STA 20+00 MATCH LINE STA SEE SHEET R13 20+00 TT VAULT F.O. 16" W 16" W 16" W 16" W 16" W 8" W 8" W 9' UTILITY EASEMENT ZEPHYR ROAD VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER 9' UTILITY EASEMENT ROUNDABOUT DETAIL SEE SHEET HC1 76' ROW 50' FL-FL STORM DRAIN G STORM DRAIN A STREET A TIMBERLINE ROAD 4.5' SIDEWALK 4.5' SIDEWALK STA. = 13+85.98 (ZEPHYR ROAD) STA. = 26+15.85 (TIMBERLINE ROAD) 4950 4955 4960 4965 4970 4950 4955 4960 4965 4970 9+75 10+00 11+00 12+00 13+00 14+00 1.59% -2.00% PVI STA = 10+56.57 PVI ELEV = 4963.55 PVI STA = 13+46.39 PVI ELEV = 4961.95 215.3' VC LP ELEV = 4961.05 LP STA = 12+41.94 PVI STA = 12+29.58 PVI ELEV = 4960.09 BCVS: 11+21.94 BVCE: 4962.25 ECVS: 13+37.22 EVCE: 4961.80 A.D. = 3.59 K = 60.00 4963.19 4962.69 4962.19 4961.75 4961.42 4961.19 4961.07 4961.05 4961.14 4961.33 4961.62 STA.=12+41.88 INV.= 4955.88 RCP STORM STA.=13+03.56 INV.= 4951.06 RCP STORM EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R11 PLAN AND PROFILE ZEPHYR DRIVE 27 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH NORTH MATCH LINE SEE SHEET R10 STA 18+00 FUTURE 50' FL-FL FUTURE 76' ROW CENTERLINE ZEPHYR ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 18+00 SEE SHT R10 R10 R11 CENTERLINE FUTURE ZEPHYR ROAD SCALE : 1" = 40' (H) 1" = 5' (V) 4955.50 4955.72 4956.05 4956.48 4957.02 4957.66 4958.40 4959.25 4960.20 4961.20 4962.19 4963.08 4963.88 EXISTING GROUND FUTURE GRADE EXISTING GROUND FUTURE GRADE X X X X FUTURE VERTICAL CURB & GUTTER 9' UTILITY EASEMENT FUTURE ZEPHYR ROAD FUTURE VERTICAL CURB & GUTTER FUTURE VERTICAL CURB & GUTTER 9' UTILITY EASEMENT FUTURE 50' FL-FL FUTURE 76' ROW ∆ R20' R40' R60' FUTURE ROUNDABOUT Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R10 PLAN AND PROFILE ZEPHYR DRIVE 26 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH NORTH MATCH LINE SEE SHEET R11 STA 18+00 LINE MATCH STA 13+00 CENTERLINE FUTURE ZEPHYR ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 18+00 SEE SHT R11 R10 R11 LINE MATCH STA 13+00 4960 4965 4970 4950 4955 4960 4965 4970 9+75 10+00 11+00 12+00 13+00 13+75 -2.25% 0.00% 2.00% -0.50% 2.38% PVI STA = 10+00.00 PVI ELEV = 4960.31 PVI STA = 10+16.00 PVI ELEV = 4959.95 PVI STA = 10+22.00 PVI ELEV = 4959.95 PVI STA = 13+04.53 PVI ELEV = 4962.09 75.0' VC HP ELEV = 4961.10 HP STA = 11+09.18 PVI STA = 10+86.68 PVI ELEV = 4961.25 BVCS: 10+49.18 BVCE: 4960.50 EVCS: 11+24.18 EVCE: 4961.06 A.D. = 2.50 K = 30.00 86.5' VC LP ELEV = 4960.67 LP STA = 12+09.30 PVI STA = 12+37.54 PVI ELEV = 4960.49 BCVS: 11+94.30 BVCE: 4960.71 ECVS: 12+80.79 EVCE: 4961.52 A.D. = 2.88 K = 30.00 4960.31 4960.01 4960.51 4960.90 4961.08 4961.05 4960.93 4960.80 4960.68 4960.71 4960.95 4961.39 4961.98 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE PROPOSED STORM MANHOLE STA.=12+08.96 INV.= 4955.61 RCP STORM STA.=12+59.54 INV.= 4952.80 RCP STORM 4960 4965 4970 4975 4980 4960 4965 4970 4975 4980 9+75 10+00 11+00 12+00 13+00 14+00 15+00 -1.00% 1.00% 1.40% PVI STA = 10+56.57 PVI ELEV = 4965.13 PVI STA = 11+65.93 PVI ELEV = 4966.22 PVI STA = 14+56.04 PVI ELEV = 4966.54 75.0' VC HP ELEV = 4967.88 HP STA = 13+06.25 PVI STA = 13+00.00 PVI ELEV = 4968.10 BVCS: 12+62.50 BVCE: 4967.57 EVCS: 13+37.50 EVCE: 4967.72 A.D. = 2.40 K = 31.25 4965.31 4965.56 4965.81 4966.06 4966.35 4966.70 4967.05 4967.40 4967.72 4967.87 4967.82 4967.60 4967.35 4967.10 4966.85 4966.60 EXISTING GROUND FUTURE GRADE EXISTING GROUND FUTURE GRADE X X X X X IRR ∆ COMMERCIAL CONNECTION 36' FL-FL 59' ROW FUTURE VERTICAL CURB & GUTTER FUTURE VERTICAL CURB & GUTTER FUTURE 4.5' SIDEWALK FUTURE 4.5' SIDEWALK TRACT C ZEPHYR ROAD Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R9 PLAN AND PROFILE STREET D & COMMERCIAL CONNECTION 25 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH NORTH STREET D CENTERLINE COMMERCIAL CONNECTION SCALE : 1" = 40' (H) 1" = 5' (V) CENTERLINE STREET D SCALE : 1" = 40' (H) 1" = 5' (V) COMMERCIAL CONNECTION STREET A SEE SHT R2 STREET A SEE SHT R2 59' ROW 36' FL-FL 2' SIDEWALK CHASE R20' R20' R20' R20' R20' R20' 4955 4960 4965 4970 4975 4955 4960 4965 4970 4975 19+25 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+75 -2.25% -0.50% 5.00% -1.85% 2.00% 0.50% -0.50% -2.00% PVI STA = 10+00.00 PVI ELEV = 4964.86 PVI STA = 10+16.00 PVI ELEV = 4964.50 PVI STA = 18+26.79 PVI ELEV = 4973.91 PVI STA = 12+73.91 PVI ELEV = 4961.92 110.0' VC HP ELEV = 4974.30 HP STA = 17+45.00 PVI STA = 17+00.00 PVI ELEV = 4974.55 BVCS: 16+45 BVCE: 4971.80 EVCS: 17+55 EVCE: 4974.27 A.D. = 5.50 K = 20.00 75.0' VC PVI STA = 12+23.91 PVI ELEV = 4962.92 BVCS: 11+86.41 BVCE: 4963.11 EVCS: 12+61.41 EVCE: 4962.17 A.D. = 1.50 K = 50.00 75.0' VC PVI STA = 13+23.91 PVI ELEV = 4962.92 BVCS: 12+86.41 BVCE: 4962.17 EVCS: 13+61.41 EVCE: 4963.11 A.D. = 1.50 K = 50.00 75.0' VC PVI STA = 10+55.94 PVI ELEV = 4963.76 BCVS: 10+18.44 BVCE: 4964.46 ECVS: 10+93.44 EVCE: 4963.58 A.D. = 1.35 K = 55.56 135.0' VC PVI STA = 14+83.50 PVI ELEV = 4963.72 BCVS: 14+16 BVCE: 4963.38 ECVS: 15+51 EVCE: 4967.10 A.D. = 4.50 K = 30.00 END PROPOSED ASPHALT STA.=15+98.16 EL. = 4969.455 4964.86 4964.34 4963.96 4963.70 4963.54 4963.42 4963.29 4963.17 4963.02 4962.77 4962.39 4961.95 4962.43 4962.80 4963.04 4963.18 4963.30 4963.44 4963.75 4964.26 4964.98 4965.91 4967.05 4968.30 4969.55 4970.80 4972.04 4973.07 4973.79 4974.20 4974.29 4974.17 4974.05 4973.92 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE FUTURE GRADE Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R8 PLAN AND PROFILE STREET C 24 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH CENTERLINE STREET C SCALE : 1" = 40' (H) 1" = 5' (V) R8 HP STA = 32+54.88 PVI STA = 32+54.88 PVI ELEV = 4963.63 BVCS: 32+17.38 BVCE: 4963.40 EVCS: 32+92.38 EVCE: 4963.40 A.D. = 1.20 K = 62.50 75.0' VC PVI STA = 37+00.32 PVI ELEV = 4961.18 BVCS: 36+62.82 BVCE: 4961.36 EVCS: 37+37.82 EVCE: 4960.43 A.D. = 1.50 K = 50.00 4961.58 4961.70 4961.82 4961.95 4962.08 4962.20 4962.32 4962.45 4962.58 4962.70 4962.85 4963.00 4963.15 4963.30 4963.44 4963.51 4963.48 4963.35 4963.20 4963.05 4962.90 4962.75 4962.60 4962.45 4962.30 4962.18 4962.05 4961.93 4961.80 4961.68 4961.55 4961.43 4961.29 4961.04 4960.67 4960.18 4960.06 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE TRACT E TRACT B STA. = 37+84.82 (STREET B) STA. = 36+19.31 (STREET A) STREET B STREET A SEE SHT R4 STREET A SEE SHT R4 R20' R20' VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK STORM DRAIN A 59' ROW 36' FL-FL TRACT E STOP SIGN w/ STREET NAME Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R7 PLAN AND PROFILE STREET B 23 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH NORTH CENTERLINE STREET B SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 28+50 SEE SHT R6 R7 R6 R5 MATCH LINE SEE SHEET R6 STA 28+50 LINE MATCH STA 33+00 LINE MATCH STA 33+00 36' FL-FL 10' CONCRETE PAN 2' SIDEWALK CHASE 6' CROSSPAN 6' CROSSPAN STOP SIGN w/ STREET NAME STOP SIGN w/ STREET NAME 4955 4960 4965 4970 4975 4955 4960 4965 4970 4975 18+50 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 28+50 2.25% -2.25% -2.00% -2.00% 2.00% 0.50% 2.00% -0.80% -0.60% PVI STA = 21+92.10 PVI ELEV = 4963.52 PVI STA = 21+98.10 PVI ELEV = 4963.52 PVI STA = 22+14.93 PVI ELEV = 4963.90 PVI STA = 22+31.77 PVI ELEV = 4963.52 PVI STA = 22+37.77 PVI ELEV = 4963.52 PVI STA = 27+50.00 PVI ELEV = 4960.20 75.0' VC PVI STA = 21+42.10 PVI ELEV = 4964.52 BVCS: 21+04.60 BVCE: 4964.74 EVCS: 21+79.60 EVCE: 4963.77 A.D. = 1.40 K = 53.57 75.0' VC HP ELEV = 4964.30 HP STA = 23+03.74 PVI STA = 22+87.77 PVI ELEV = 4964.52 BVCS: 22+50.27 BVCE: 4963.77 EVCS: 23+25.27 EVCE: 4964.22 A.D. = 2.80 K = 26.74 75.0' VC PVI STA = 27+00.00 PVI ELEV = 4961.20 BVCS: 26+62.50 BVCE: 4961.50 EVCS: 27+37.50 EVCE: 4960.45 A.D. = 1.20 K = 62.76 75.0' VC PVI STA = 28+00.00 PVI ELEV = 4961.20 BVCS: 27+62.50 BVCE: 4960.45 EVCS: 28+37.50 EVCE: 4961.39 A.D. = 1.50 K = 50.00 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE 4966.12 4965.97 4965.82 4965.67 4965.52 4965.37 4965.22 4965.07 4964.92 4964.77 4964.58 4964.28 4963.86 4963.56 4963.67 4963.76 4964.15 4964.30 4964.22 4964.02 4963.82 4963.61 4963.41 4963.21 4963.01 4962.81 4962.61 4962.41 4962.21 4962.00 4961.80 4961.60 4961.39 4961.09 4960.69 4960.20 4960.68 4961.06 4961.31 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R6 PLAN AND PROFILE STREET B 22 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH MATCH LINE SEE SHEET R6 STA 18+50 CENTERLINE STREET B SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 28+50 SEE SHT R7 R7 R6 R5 MATCH LINE SEE SHEET R5 STA 18+50 LINE MATCH STA 18+50 SEE SHT R5 4966.57 4970.91 4970.96 4970.91 4970.62 4970.47 4970.32 4970.02 4969.87 4969.72 4969.42 4969.27 4969.12 4968.82 4968.67 4968.52 4968.22 4968.07 4967.92 4967.62 4967.47 4967.32 4967.02 4966.87 4966.72 4966.42 ∆ ∆ ∆ 9' UTILITY EASEMENT STREET B LOT 4 LOT 3 LOT 7 LOT 6 LOT 3 LOT 2 LOT 1 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 5 LOT 4 LOT 2 LOT 19 LOT 14 LOT 18 LOT 15 LOT 16 LOT 13 LOT 17 LOT 9 LOT 8 LOT 7 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK LOT 1 TRACT I BLOCK 7 BLOCK 2 BLOCK 8 BLOCK 9 DRIVE-OVER CURB & GUTTER DRIVE-OVER CURB & GUTTER 36' FL-FL 59' ROW Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R5 PLAN AND PROFILE STREET B 21 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH NORTH MATCH LINE SEE SHEET R6 STA 18+50 LINE MATCH STA 12+00 CENTERLINE STREET B SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 18+50 SEE SHT R5 R7 R6 R5 LINE MATCH STA 12+00 0.50% -0.50% 0.50% -0.60% PVI STA = 39+66.27 PVI ELEV = 4963.24 75.0' VC HP ELEV = 4961.00 HP STA = 33+25.00 PVI STA = 33+25.00 PVI ELEV = 4961.09 BVCS: 32+87.50 BVCE: 4960.90 EVCS: 33+62.50 EVCE: 4960.90 A.D. = 1.00 K = 75.00 75.0' VC LP ELEV = 4960.20 LP STA = 31+29.91 PVI STA = 31+26.50 PVI ELEV = 4960.10 BCVS: 30+89 BVCE: 4960.32 ECVS: 31+64 EVCE: 4960.29 A.D. = 1.10 K = 68.18 75.0' VC LP ELEV = 4959.94 LP STA = 35+75.00 PVI STA = 35+75.00 PVI ELEV = 4959.84 BCVS: 35+37.50 BVCE: 4960.03 ECVS: 36+12.50 EVCE: 4960.03 A.D. = 1.00 K = 75.00 75.0' VC PVI STA = 38+22.22 PVI ELEV = 4961.08 BCVS: 37+84.72 BVCE: 4960.89 ECVS: 38+59.72 EVCE: 4961.64 A.D. = 1.00 K = 75.00 4960.27 4960.47 4960.96 4960.72 4960.22 4959.98 4960.47 4960.98 4962.25 4960.41 4960.20 4960.23 4960.34 4960.59 4960.72 4960.84 4961.00 4960.96 4960.84 4960.59 4960.47 4960.34 4960.09 4959.98 4959.94 4960.09 4960.22 4960.34 4960.59 4960.72 4960.84 4961.20 4961.50 4961.87 4962.62 4963.00 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE STA.=36+09.38 INV.= 4952.43 RCP STORM STA.=35+62.56 INV.= 4954.91 RCP STORM STA.=31+29.96 INV.= 4954.43 RCP STORM Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R4 PLAN AND PROFILE STREET A 20 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH CENTERLINE STREET A SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R3 STA 30+50 LINE MATCH STA 30+50 SEE SHT R3 R4 R3 R2 R1 PVI ELEV = 4960.20 75.0' VC PVI STA = 24+53.97 PVI ELEV = 4961.20 BVCS: 24+16.47 BVCE: 4961.42 EVCS: 24+91.47 EVCE: 4960.45 A.D. = 1.40 K = 53.57 75.0' VC PVI STA = 25+53.97 PVI ELEV = 4961.20 BVCS: 25+16.47 BVCE: 4960.45 EVCS: 25+91.47 EVCE: 4961.39 A.D. = 1.50 K = 50.00 75.0' VC HP ELEV = 4962.16 HP STA = 27+62.85 PVI STA = 27+66.26 PVI ELEV = 4962.26 BVCS: 27+28.76 BVCE: 4962.07 EVCS: 28+03.76 EVCE: 4962.04 A.D. = 1.10 K = 68.18 4961.67 4961.52 4961.37 4961.12 4960.75 4960.28 4960.61 4961.01 4961.28 4961.43 4961.56 4961.68 4961.81 4961.93 4962.06 4962.15 4962.15 4962.06 4961.91 4961.76 4961.61 4961.46 4961.31 4961.16 4961.01 4960.86 4960.71 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R3 PLAN AND PROFILE STREET A 19 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH MATCH LINE SEE SHEET R4 STA 30+50 CENTERLINE STREET A SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R2 STA 23+50 LINE MATCH STA 30+50 SEE SHT R4 LINE MATCH STA 23+50 SEE SHT R2 R4 R3 R2 R1 4975 4955 4960 4965 4970 4975 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 23+50 -0.60% -0.70% PVI STA = 18+43.54 PVI ELEV = 4964.86 EXISTING GROUND PROPOSED GRADE 4966.39 4966.22 4966.04 4965.87 4965.69 4965.52 4965.34 4965.17 4964.99 4964.82 4964.67 4964.52 4964.37 4964.22 4964.07 4963.92 4963.77 4963.62 4963.47 4963.32 4963.17 4963.02 4962.87 4962.72 4962.57 4962.42 4962.27 4962.12 4961.97 EXISTING GROUND PROPOSED GRADE Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R2 PLAN AND PROFILE STREET A 18 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH MATCH LINE SEE SHEET R3 STA 23+50 CENTERLINE STREET A SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R1 STA 16+00 LINE MATCH STA SEE SHT 23+50 R3 LINE MATCH STA 16+00 SEE SHT R1 R4 R3 R2 R1 4968.49 4968.32 4968.14 4967.97 4967.79 4967.62 4967.44 4967.27 4967.09 4966.92 4966.74 EXISTING GROUND PROPOSED GRADE ∆ ∆ LOT 4 LOT 3 LOT 2 LOT 32 LOT 31 LOT 27 LOT 30 LOT 29 LOT 28 LOT 26 LOT 25 LOT 2 LOT 3 LOT 1 BLOCK 10 BLOCK 2 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT STREET A 59' ROW 36' FL-FL STREET A BLOCK 13 TRACT G TRACT G TRACT A TRACT A 4.5' SIDEWALK 4.5' SIDEWALK 59' ROW 36' FL-FL DRIVE-OVER CURB & GUTTER DRIVE-OVER CURB & GUTTER Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com R1 PLAN AND PROFILE STREET A 17 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE KEYMAP B M VAULT ELEC TIMBERLINE RD CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH NORTH MATCH LINE SEE SHEET R2 STA 16+00 LINE MATCH STA 12+00 LINE MATCH STA 12+00 CENTERLINE STREET A SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 16+00 SEE SHT R2 R4 R3 R2 R1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 8" W IRR IRR IRR IRR IRR IRR IRR 9' UTILITY EASEMENT 9' UTILITY EASEMENT ZEPHYR ROAD 50' FL-FL 76' ROW TIMBERLINE RD 15' UTILITY EASEMENT 128' ROW 127' ROW STORM DRAIN G STORM DRAIN A TRACT C STMH A1 EX STMH A OUTLET A1-1 INLET G2 INLET G1 FES G TRACT D ZEPHYR ROAD ROSEN RD THE TIMBERS PUD WESTCHASE PUD CROWNE ON TIMBERLINE CONNECT TO EXISTING STORM MANHOLE 1.5% RENNAT, HARRY O TRUST DETENTION POND 3 100-YR VOL=0.81 ac PEAK RELEASE=1.10 cfs FUTURE DETENTION POND 4 100-YR VOL=0.79 ac PEAK RELEASE=0.59 cfs G5 GRADING PLAN 16 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH G1 G3 G2 G4 G5 MATCHLINE-SEE SHEET G5 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) STREET B STREET D 15' UTILITY EASEMENT 15' UTILITY EASEMENT 15' UTILITY EASEMENT 108' ROW 120' ROW 120' ROW STORM DRAIN A STORM DRAIN D SIGHT DISTANCE EASEMENT STORM DRAIN A STORM DRAIN B STORM DRAIN A STORM DRAIN E STORM DRAIN C TRACT E TRACT B TRACT D LOT 6 LOT 56 LOT 54 LOT 55 LOT 57 LOT 58 LOT 42 LOT 4 LOT 7 LOT 3 LOT 5 LOT 2 LOT 4 LOT 1 LOT 8 LOT 7 LOT 6 LOT 5 LOT 2 LOT 3 LOT 1 LOT 45 LOT 44 LOT 43 LOT 38 LOT 40 LOT 41 LOT 39 TRACT F TRACT A RAIN GARDEN 2 INLET B2 INLET B3 INLET B1-1 INLET B1-2 STMH B1 FES B STMH A7 STMH A6 STMH A5 STMH A3-2 STMH A8 STMH A2 STMH A4 STMH A3 STMH A3-1 OUTLET STRUCTURE A9 OUTLET STRUCTURE A3-1.1 OUTLET STRUCTURE A3-3 INLET C2 INLET C1 FES C STMH D1 INLET D2 FES D INLET E1 FES E FES H 2' CONCRETE PAN 2' CONCRETE PAN 2' CONCRETE PAN 2' CONCRETE PAN 6' CROSSPAN 6' CROSSPAN 1.1% 0.5% 0.5% 1.1% 0.6% 0.7% 15.4% 12.9% 21.3% 11.6% 0.6% 0.6% 2.1% 2.2% 2.4% 2.0% 2.1% 2.1% 5.7% 12.0% 16.9% 10.7% 8.5% 10.7% 16.1% 2.1% 1.7% 2.4% 1.9% 1.9% 1.9% 2.4% 1.3% 1.9% 2.0% 1.3% 1.7% 1.1% 1.1% 1.6% 3.2% 3.1% 10.5% 14.6% 9.3% 10.0% 2.3% STORM DRAIN H LIEBL MRD CITY OF FORT COLLINS BACON ELEMENTARY POUDRE SCHOOL DISTRICT DITCH LATERAL 0.5% 0.5% 0.5% 0.5% 0.5% RENNAT, HARRY O TRUST DETENTION POND 1 100-YR VOL=7.86 ac PEAK RELEASE=1.45 cfs DETENTION POND 2B 100-YR VOL=1.61 ac PEAK RELEASE=6.58 cfs DETENTION POND 2A 100-YR VOL=1.20 ac PEAK RELEASE=0.86 cfs BLOCK 1 BLOCK 3 BLOCK 2 BLOCK 3 G4 GRADING PLAN 15 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH G1 G3 G2 G4 G5 MATCHLINE-SEE SHEET G3 MATCHLINE-SEE SHEET G2 MATCHLINE-SEE SHEET G5 LOT 3 LOT 7 LOT 5 LOT 4 LOT 2 LOT 1 LOT 19 LOT 18 LOT 17 LOT 16 LOT 12 LOT 14 LOT 13 LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 4 LOT 4 LOT 3 LOT 19 LOT 17 LOT 23 LOT 24 LOT 25 LOT 26 LOT 27 LOT 28 LOT 16 LOT 15 LOT 14 LOT 11 LOT 12 LOT 10 LOT 9 LOT 8 LOT 7 TRACT A DETENTION POND 1 RAIN GARDEN 1 INLET F1 FES F CLEANOUT F2 2' CONCRETE PAN 2' CONCRETE PAN 10' CONCRETE PAN 10' CONCRETE PAN 6' CROSSPAN 6' CROSSPAN TRACT I 2.1% 2.4% 2.2% 2.2% 2.1% 4.0% 9.7% 9.8% 9.6% 8.4% 6.5% 9.4% 8.8% 2.1% 2.1% 2.1% 1.2% 2.5% 2.2% 2.1% 2.1% 1.3% 2.0% 1.7% 3.8% 2.3% 1.3% 4.5% 1.2% 3.1% 3.6% 2.3% 6.4% 2.3% 1.1% 2' CURB CUT & SIDEWALK CHASE 2' CURB CUT & SIDEWALK CHASE 2' CURB CUT & SIDEWALK CHASE RENNAT, HARRY O TRUST DITCH LATERAL 0.5% 0.5% PROPOSED TYPE III BARRICADE BLOCK 5 BLOCK 14 BLOCK 3 BLOCK 4 BLOCK 2 BLOCK 1 BLOCK 3 DITCH LATERAL G3 GRADING PLAN 14 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH G1 G3 G2 G4 G5 MATCHLINE-SEE SHEET G3 MATCHLINE-SEE SHEET G1 MATCHLINE-SEE SHEET G2 LOT 33 LOT 31 LOT 30 LOT 28 LOT 38 LOT 40 LOT 36 LOT 39 LOT 37 TRACT F DETENTION POND 1 RAIN GARDEN 2 INLET E1 CLEANOUT E2 FES H1 10' CONCRETE PAN 2' CONCRETE PAN 10.7% 16.1% 2.1% 1.2% 2.0% 1.3% 1.1% 1.1% 2.1% 2.3% 2.1% 7.5% 11.6% 7.0% 6.1% 2.8% 2.8% STORM DRAIN H 2' CURB CUT & SIDEWALK CHASE WILLOW SPRINGS PUD MAIL CREEK DITCH LIEBL MRD WILLOW SPRINGS PUD BLOCK 2 BLOCK 2 BLOCK 3 G2 GRADING PLAN 13 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH G1 G3 G2 G4 G5 MATCHLINE-SEE SHEET G1 MATCHLINE-SEE SHEET G4 MATCHLINE-SEE SHEET G3 TRACT H LOT 17 LOT 3 LOT 3 LOT 37 LOT 36 LOT 38 LOT 39 LOT 34 LOT 33 LOT 35 LOT 32 LOT 31 LOT 27 LOT 30 LOT 29 LOT 28 LOT 24 LOT 26 LOT 21 LOT 22 LOT 23 LOT 25 LOT 20 LOT 19 LOT 14 LOT 18 LOT 15 LOT 16 LOT 13 LOT 11 LOT 5 LOT 1 LOT 2 LOT 5 LOT 4 LOT 4 LOT 1 LOT 2 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 LOT 2 LOT 5 LOT 4 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 LOT 2 LOT 5 LOT 4 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 7 LOT 6 LOT 5 LOT 12 LOT 10 LOT 4 LOT 3 LOT 4 LOT 3 TRACT G LOT 4 LOT 3 LOT 3 LOT 3 TRACT I LOT 1 LOT 2 LOT 7 LOT 6 LOT 5 LOT 3 LOT 7 LOT 6 LOT 1 LOT 2 LOT 3 LOT 23 LOT 24 LOT 25 LOT 26 LOT 27 TRACT A TRACT A 2.2% 2.1% 2.0% 2.0% 2.0% 2.0% 2.2% 2.1% 2.1% 2.1% 2.8% 1.0% 2.4% 0.6% 0.9% 7.2% 4.1% 6.2% 7.9% 5.7% 2.0% 2.1% 2.8% 4.9% 2.7% 2.0% 2.1% 1.2% 0.9% 1.6% 1.1% 1.1% 1.1% 1.2% 0.6% 1.1% WILLOW SPRINGS PUD BLOCK 10 BLOCK 9 BLOCK 8 BLOCK 11 BLOCK 12 BLOCK 6 BLOCK 7 BLOCK 5 BLOCK 13 BLOCK 14 BLOCK 2 BLOCK 2 BLOCK 2 BLOCK 3 G1 GRADING PLAN 12 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH G1 G3 G2 G4 G5 MATCHLINE-SEE SHEET G2 MATCHLINE-SEE SHEET G3 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W IRR BLOCK 3 BLOCK 2 BLOCK 10 BLOCK 9 BLOCK 8 BLOCK 11 BLOCK 12 BLOCK 13 BLOCK 14 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 7 BLOCK 1 BLOCK 3 BLOCK 2 BLOCK 3 BLOCK 2 TRACT E TRACT D TRACT F TRACT I TRACT G TRACT A TRACT B TRACT C DETENTION POND 2B STORM DRAIN G STORM DRAIN A STORM DRAIN A STORM DRAIN D STORM DRAIN A STORM DRAIN B STORM DRAIN A STORM DRAIN E STORM DRAIN F STORM DRAIN C STORM DRAIN H DETENTION POND 1 STREET A STREET B STREET A STREET B ALLEY ALLEY ZEPHYR ROAD TIMBERLINE RD TIMBERLINE RD STREET A STREET A STREET B STREET C STREET C STREET B STREET D DETENTION POND 2A DETENTION POND 3 FUTURE DETENTION POND 3 ( IN FEET ) 0 1 INCH = 150 FEET 150 150 300 450 OG1 GRADING PLAN OVERALL 11 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD LEGEND: ST 36.25 (36.25) PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NORTH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 8" W IRR IRR IRR IRR IRR IRR IRR SSMH 2 EX SSMH 1 STMH A1 EX STMH A OUTLET A1-1 INLET G2 INLET G1 FES G 10" PVC SANITARY SEWER 8" PVC SANITARY SEWER 12" PVC SANITARY SEWER TRACT C STORM DRAIN G 45° BEND w/ TB N:100357.01 E:204963.33 45° BEND w/ TB N:100408.16 E:204911.67 BEGIN HORZ. DEFLECTION N:100487.40 E:204911.29 STORM DRAIN A 9' UTILITY EASEMENT 9' UTILITY EASEMENT ZEPHYR ROAD 276.46 LF 8" PVC S89°43'20"W 72.70 LF 8" PVC N45°16'40"W 79.24 LF 8" PVC N00°16'40"W 50' FL-FL 76' ROW TIMBERLINE RD TRACT B TRACT D 15' UTILITY EASEMENT 128' ROW 127' ROW ZEPHYR ROAD ROSEN RD THE TIMBERS PUD WESTCHASE PUD CROWNE ON TIMBERLINE 16"x8" TEE w/TB 1 - 8" GV (W) N:100358.35 E:205239.79 CONNECT TO EXISTING 16" WATER CONNECT TO EXISTING STORM MANHOLE CONNECT TO EXISTING SANITARY MANHOLE DETENTION POND 3 U5 UTILITY PLAN 10 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTIONS SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE ELCO AND BOXELDER STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 10. ALL FITTINGS, TEES, PLUGS AND FIRE HYDRANTS SHALL BE PROVIDED WITH ANCHOR COUPLINGS AND/OR JOINT RESTRAINT IN ACCORDANCE WITH ELCO SPECIFICATIONS. THRUST BLOCKS SHALL BE USED ONLY AS REQUIRED PER FIELD CONDITIONS AND AS APPROVED OR DIRECTED BY THE ELCO FIELD INSPECTOR. W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH U1 U3 U2 U4 U5 MATCHLINE-SEE SHEET U4 STMH A4 STMH A3 STMH A3-1 OUTLET STRUCTURE A9 OUTLET STRUCTURE A3-1.1 OUTLET STRUCTURE A3-3 INLET B2 INLET B3 INLET B1-1 INLET B1-2 STMH B1 FES B INLET C2 INLET C1 FES C STMH D1 INLET D2 FES D INLET E1 FES E 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER 8" PVC SANITARY SEWER LOT 58 LOT 3 LOT 5 LOT 2 LOT 4 LOT 1 TRACT A LOT 56 LOT 54 LOT 55 LOT 57 TRACT E TRACT B TRACT D BEGIN HORZ. DEFLECTION N:100487.40 E:204911.29 PRC HORIZ. DEFLECTION N:100544.49 E:204916.49 8"x6" SWIVEL TEE 1 - 6" GV (E) N:100546.82 E:204916.93 FH ASSEMBLY N:100544.09 E:204931.68 END HORZ. DEFLECTION N:100683.58 E:204929.50 8"x8" TEE w/TB 3 - 8" GV (N,W,S) N:100764.00 E:204929.50 STORM DRAIN A STORM DRAIN D 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT SIGHT DISTANCE EASEMENT BEGIN HORZ. DEFLECTION N:100764.00 E:204598.41 8"x6" SWIVEL TEE 1 - 6" GV (SW) N:100815.82 E:204382.67 FH ASSEMBLY N:100807.10 E:204378.24 END HORZ. DEFLECTION N:100890.45 E:204275.71 STORM DRAIN A BEGIN HORZ. DEFLECTION N:101178.86 E:204929.50 PRC HORZ. DEFLECTION N:101208.75 E:204930.99 FH ASSEMBLY N:101280.86 E:204939.92 79.24 LF 8" PVC N00°16'40"W 100.42 LF 8" PVC N00°00'00"E 331.09 LF 8" PVC N90°00'00"E 381.77 LF 8" PVC S47°12'15"E 5 7 . 4 1 L F 8 " P V C R = 3 0 0 . 0 0 ' 29.94 LF 8" PVC R=300.00' 130 . 8 4 L F 8 " P V C R = 47 5 .0 0 ' 28.80 LF 8" PVC R=303.00' 42.05 LF 8" PVC R=303.00' 3 2 7 . 09 L F 8 " P V C R = 3 03 . 0 0 ' 305.08 LF 8" PVC N90°00'00"W TIMBERLINE RD TIMBERLINE RD 8"x6" SWIVEL TEE 1 - 6" GV (E) N:101279.42 E:204929.78 59' ROW 36' FL-FL 36' FL-FL 59' ROW 59' ROW 36' FL-FL STORM DRAIN B STORM DRAIN A STREET A STREET A 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) STORM DRAIN E LOT 44 LOT 43 LOT 45 LOT 38 LOT 40 LOT 41 LOT 39 LOT 42 LOT 6 LOT 5 LOT 3 LOT 4 LOT 1 BLOCK 1 BLOCK 3 BLOCK 3 BLOCK 2 TRACT F STREET B STREET D 15' UTILITY EASEMENT 15' UTILITY EASEMENT 15' UTILITY EASEMENT 108' ROW 120' ROW 120' ROW STORM DRAIN C LIEBL MRD CITY OF FORT COLLINS BACON ELEMENTARY POUDRE SCHOOL DISTRICT DITCH LATERAL 16"x8" TEE w/TB 1 - 8" GV (W) N:101237.49 E:205237.57 8"x8" CROSS w/TB 4 - 8" GV (N,E,W,S) N:101237.49 E:204932.50 CONNECT TO EXISTING 16" WATER STORM DRAIN H FES H 157.72 LF 8" PVC N00°00'00"E 237.14 LF 8" PVC N00°00'00"E TEMP FH ASSEMBLY w/ 8"x6" REDUCER N:101021.14 E:204958.00 8"x8" TEE w/TB 1 - 8" GV (E) N:101021.14 E:204929.50 TEMP FH ASSEMBLY w/ 8"x6" REDUCER N:101237.49 E:204881.00 TEMP FH ASSEMBLY w/ 8"x6" REDUCER N:100610.14 E:204955.40 8"x8" TEE w/TB 1 - 8" GV (E) N:100612.91 E:204926.16 7 0 .7 7 L F 8 " PV C R = 75 0 . 0 0 ' 6 9 . 12 L F 8 " PV C R = 750. 00 ' PROPOSED SANITARY SEWER STUB PROPOSED SANITARY SEWER STUB PROPOSED SANITARY SEWER STUB DETENTION POND 2B DETENTION POND 2A DETENTION POND 1 18 7 .1 2 L F 8 " P V C R = 47 5. 0 0 ' 1 8 7 .12 L F 8 " P V C R = 4 75 . 00 ' 8"x8" TEE w/TB 1 - 8" GV (NE) N:100800.38 E:204416.09 TEMP FH ASSEMBLY w/ 8"x6" REDUCER N:100847.58 E:204435.63 36.83 LF 8" PVC R=475.00' U4 UTILITY PLAN 9 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTIONS SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE ELCO AND BOXELDER STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 10. ALL FITTINGS, TEES, PLUGS AND FIRE HYDRANTS SHALL BE PROVIDED WITH ANCHOR COUPLINGS AND/OR JOINT RESTRAINT IN ACCORDANCE WITH ELCO SPECIFICATIONS. THRUST BLOCKS SHALL BE USED ONLY AS REQUIRED PER FIELD CONDITIONS AND AS APPROVED OR DIRECTED BY THE ELCO FIELD INSPECTOR. W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH U1 U3 U2 U4 U5 MATCHLINE-SEE SHEET U3 MATCHLINE-SEE SHEET U2 MATCHLINE-SEE SHEET U5 1 - 6" GV (SW) N:101540.81 E:203573.28 FH ASSEMBLY N:101531.85 E:203564.99 TEMP FH ASSEMBLY w/ 8"x6" REDUCER N:101408.03 E:203510.99 BEGIN HORZ. DEFLECTION N:101670.67 E:203754.16 285.00 LF 8" PVC S59°07'06"E 381.77 LF 8" PVC S47°12'15"E 70.17 LF 8" PVC S47°12'15"E 44.50 LF 8" PVC S47°12'15"E 531.00 LF 8" PVC S47°12'15"E 164 .27 L F 8 " P V C R = 7 9 0 . 0 0 ' 218.18 LF 8" PVC S42°47'45"W 139.75 LF 8" PVC S42°47'45"W 1 5 3 . 6 5 L F 8 " PV C R = 3 0 0 .0 0 ' LOT 26 LOT 27 LOT 28 LOT 29 LOT 23 LOT 24 LOT 25 LOT 19 LOT 21 LOT 18 LOT 22 LOT 20 LOT 17 LOT 16 LOT 15 LOT 14 LOT 11 LOT 12 LOT 10 LOT 9 LOT 13 LOT 15 LOT 8 LOT 7 LOT 6 LOT 5 LOT 23 LOT 3 LOT 7 LOT 6 LOT 5 LOT 4 LOT 7 LOT 6 LOT 5 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 4 LOT 1 LOT 2 LOT 3 BLOCK 2 BLOCK 14 BLOCK 4 STORM DRAIN F BLOCK 5 9' UTILITY EASEMENT 9' UTILITY EASEMENT 24' FL-FL 36' FL-FL 59' ROW 9' UTILITY EASEMENT 9' UTILITY EASEMENT TRACT G TRACT I 59' ROW 36' FL-FL BLOCK 1 BLOCK 3 BLOCK 3 BLOCK 3 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) STREET B STREET B STREET C STREET C 9' UTILITY EASEMENT 9' UTILITY EASEMENT DETENTION POND 1 RENNAT, HARRY O TRUST DITCH LATERAL PROPOSED TYPE III BARRICADE DITCH LATERAL U3 UTILITY PLAN 8 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTIONS SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE ELCO AND BOXELDER STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 10. ALL FITTINGS, TEES, PLUGS AND FIRE HYDRANTS SHALL BE PROVIDED WITH ANCHOR COUPLINGS AND/OR JOINT RESTRAINT IN ACCORDANCE WITH ELCO SPECIFICATIONS. THRUST BLOCKS SHALL BE USED ONLY AS REQUIRED PER FIELD CONDITIONS AND AS APPROVED OR DIRECTED BY THE ELCO FIELD INSPECTOR. W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH U1 U3 U2 U4 U5 MATCHLINE-SEE SHEET U4 MATCHLINE-SEE SHEET U1 MATCHLINE-SEE SHEET U2 375.81 LF 8" PVC N63°48'45"W 29.94 LF 8" PVC R=300.00' TIMBERLINE RD STREET A 10' CONCRETE TRAIL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 36' FL-FL 59' ROW 6' UE 3' DRAINAGE EASEMENT (TYP.) 6' UE 3' DRAINAGE EASEMENT (TYP.) LOT 38 LOT 40 LOT 39 LOT 35 LOT 34 LOT 32 LOT 33 LOT 31 LOT 36 LOT 37 LOT 30 LOT 29 10' CONCRETE TRAIL TRACT A BLOCK 3 BLOCK 2 BLOCK 2 TRACT F 100' ROW DETENTION POND 1 WILLOW SPRINGS PUD MAIL CREEK DITCH LIEBL MRD FES H1 STORM DRAIN H WILLOW SPRINGS PUD U2 UTILITY PLAN 7 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTIONS SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE ELCO AND BOXELDER STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 10. ALL FITTINGS, TEES, PLUGS AND FIRE HYDRANTS SHALL BE PROVIDED WITH ANCHOR COUPLINGS AND/OR JOINT RESTRAINT IN ACCORDANCE WITH ELCO SPECIFICATIONS. THRUST BLOCKS SHALL BE USED ONLY AS REQUIRED PER FIELD CONDITIONS AND AS APPROVED OR DIRECTED BY THE ELCO FIELD INSPECTOR. W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 NORTH U1 U3 U2 U4 U5 MATCHLINE-SEE SHEET U1 MATCHLINE-SEE SHEET U4 MATCHLINE-SEE SHEET U3 LOT 28 LOT 24 LOT 26 LOT 21 LOT 22 LOT 23 LOT 25 LOT 20 LOT 19 LOT 14 LOT 18 LOT 15 LOT 16 LOT 13 LOT 11 LOT 12 LOT 10 LOT 17 TRACT G TRACT I ALLEY ALLEY 59' ROW 36' FL-FL 24' FL-FL 10' CONCRETE TRAIL 10' CONCRETE TRAIL 6' UE 3' DRAINAGE EASEMENT (TYP.) FH ASSEMBLY N:101904.94 E:203893.64 8"x6" SWIVEL TEE 1 - 6" GV (N) N:101893.06 E:203890.80 8"x8" TEE w/TB 3 - 8" GV (N,W,S) N:101902.99 E:203849.31 BEGIN HORZ. DEFLECTION N:101941.12 E:203689.84 END HORZ. DEFLECTION N:102158.16 E:203469.08 8"x6" SWIVEL TEE 1 - 6" GV (NE) N:102310.29 E:203429.95 FH ASSEMBLY N:102315.18 E:203448.94 45° BEND w/ TB N:102338.25 E:203422.76 22.5° BEND w/ TB N:102351.64 E:203400.09 END HORZ. DEFLECTION N:102354.57 45° BEND w/ TB E:203352.96 N:102350.81 E:203127.07 45° BEND w/ TB N:102311.90 E:203096.54 11.25° BEND w/ TB N:102332.94 E:203109.79 BEGIN HORZ. DEFLECTION N:102184.81 E:203125.42 8"x6" SWIVEL TEE 1 - 6" GV (W) N:101942.17 E:203143.52 FH ASSEMBLY N:101942.49 E:203131.32 END HORZ. DEFLECTION N:101988.42 E:203144.77 11.25° BEND w/ TB N:101855.69 E:203141.19 45° BEND w/ TB N:101833.08 E:203145.96 END HORZ. DEFLECTION N:101804.71 E:203825.80 26.32 LF 8" PVC N59°25'28"W 225.92 LF 8" PVC S89°02'47"W 24.86 LF 8" PVC S44°02'47"W 24.86 LF 8" PVC S32°11'50"W 130.34 LF 8" PVC S12°48'10"E 120.01 LF 8" PVC N76°33'00"W 42.66 LF 8" PVC N76°33'00"W 163.96 LF 8" PVC N76°33'00"W 157.08 LF 8" PVC N14°25'28"W 28.87 LF 8" PVC N14°25'28"W 86.50 LF 8" PVC N01°32'47"E 46.28 LF 8" PVC N01°32'47"E 11 3 . 38 L F 8 " P V C R = 5 1 0 . 0 0 ' 3 2 5 . 2 9 L F 8 " P V C R = 3 0 0 . 0 0 ' 47.28 LF 8" PVC R=300.00' 1 9 7 . 8 5 L F 8 " P V C R = 7 9 0 . 00 ' 23.12 LF 8" PVC R=300.00' 101.05 LF 8" PVC S13°27'00"W C STREET A 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 26 LOT 27 LOT 23 LOT 24 LOT 25 TRACT A TRACT A 9' UTILITY EASEMENT 9' UTILITY EASEMENT STREET C LOT 23 LOT 4 LOT 1 LOT 2 LOT 7 LOT 6 LOT 5 LOT 5 LOT 3 LOT 4 LOT 7 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 1 LOT 2 LOT 3 LOT 1 LOT 2 LOT 5 LOT 4 LOT 3 LOT 3 LOT 1 LOT 2 LOT 5 LOT 4 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 5 LOT 4 LOT 1 LOT 2 LOT 3 LOT 2 LOT 5 LOT 4 LOT 3 LOT 1 LOT 2 LOT 3 LOT 7 LOT 6 LOT 5 LOT 4 LOT 5 LOT 4 LOT 1 LOT 2 LOT 3 LOT 1 BLOCK 2 BLOCK 2 BLOCK 2 BLOCK 13 BLOCK 14 BLOCK 5 BLOCK 6 BLOCK 12 BLOCK 7 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT BLOCK 11 BLOCK 8 BLOCK 10 BLOCK 9 36' FL-FL 59' ROW BLOCK 2 9' UTILITY EASEMENT 9' UTILITY EASEMENT WILLOW SPRINGS PUD MAIL CREEK DITCH U1 UTILITY PLAN 6 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 5. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 6. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTIONS SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAINE CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 8. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE ELCO AND BOXELDER STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 10. ALL FITTINGS, TEES, PLUGS AND FIRE HYDRANTS SHALL BE PROVIDED WITH ANCHOR COUPLINGS AND/OR JOINT RESTRAINT IN ACCORDANCE WITH ELCO SPECIFICATIONS. THRUST BLOCKS SHALL BE USED ONLY AS REQUIRED PER FIELD CONDITIONS AND AS APPROVED OR DIRECTED BY THE ELCO FIELD INSPECTOR. W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE NORTH U1 U3 U2 U4 U5 MATCHLINE-SEE SHEET U2 MATCHLINE-SEE SHEET U3 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W IRR PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT 8" WATER 8" SANITARY 8" WATER 8" SANITARY 8" WATER 8" SANITARY 8" WATER 8" SANITARY 8" WATER 8" SANITARY 8" WATER 8" SANITARY STREET A STREET B STREET A STREET B ALLEY ALLEY ZEPHYR ROAD TIMBERLINE RD TIMBERLINE RD STREET A STREET A STREET B STREET C STREET C STREET B STREET D BLOCK 3 BLOCK 3 BLOCK 2 BLOCK 2 BLOCK 3 BLOCK 3 BLOCK 1 BLOCK 1 BLOCK 2 BLOCK 12 BLOCK 7 BLOCK 11 BLOCK 14 BLOCK 13 BLOCK 8 BLOCK 6 BLOCK 4 BLOCK 5 BLOCK 10 BLOCK 9 BLOCK 2 TRACT F TRACT E TRACT A TRACT D TRACT B TRACT C TRACT A TRACT G TRACT I 8" WATER 8" SANITARY 8" WATER 8" WATER PROPOSED TEMPORARY FIRE HYDRANT PROPOSED TEMPORARY FIRE HYDRANT PROPOSED TEMPORARY FIRE HYDRANT PROPOSED TEMPORARY FIRE HYDRANT EXISTING 16" WATER PROPOSED SANITARY STUB PROPOSED SANITARY STUB PROPOSED SANITARY STUB PROPOSED TEMPORARY FIRE HYDRANT PROPOSED FIRE HYDRANT ( IN FEET ) 0 1 INCH = 150 FEET 150 150 300 450 OU1 UTILITY PLAN OVERALL 5 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R KEYMAP B M VAULT ELEC TIMBERLINE RD EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE NORTH M F.O. 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W IRR / / / / / / / / / / / / / / / / / / / / / / / REMOVE AND REPLACE EXISTING 3'x7.5' BOX CULVERT - SEE UTILITY PLANS RELOCATE EXISTING FIRE HYDRANT REMOVE AND REPLACE EXISTING 18" RCP STORM SEWER - SEE UTILITY PLANS EXISTING DITCH TO REMAIN ABANDONED 18" CMP STORM CULVERT RELOCATE EXISTING FIBER OPTIC VAULT RELOCATE EXISTING TELEPHONE PED MILL AND OVERLAY TO CORRECT LOW CROSS-SLOPE 50' DITCH BUFFER 50' DITCH BUFFER ZEPHYR ROAD TIMBERLINE RD ROSEN RD BACON ELEMENTARY POUDRE SCHOOL DISTRICT CITY OF FORT COLLINS WILLOW SPRINGS PUD THE TIMBERS PUD WESTCHASE CROWNE ON PUD TIMBERLINE RENNAT, HARRY O TRUST LIEBL MRD MAIL CREEK DITCH DITCH LATERAL RED WILLOW DR EXISTING 79' ROW EXISTING DITCH LATERAL TO REMAIN UNION-PACIFIC RAILROAD 14° SPECIAL BEND INV=4954.53 EXISTING 30" IRRIGATION PIPE EXISTING IRRIGATION MH INV W=4953.43 EXISTING IRRIGATION MH INV=4956.16 EXISTING IRRIGATION STRUCTURE TO BE MOVED WITH PHASE 2 EXISTING IRRIGATION MH INV=4951.99 EXISTING 18" IRRIGATION PIPE ( IN FEET ) 0 1 INCH = 150 FEET 150 150 300 450 EX1 AND DEMOLITION PLAN EXISTING CONDITIONS 4 Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) APPROXIMATE LIMITS OF CONCRETE/ ASPHALT REMOVAL OR MILL & OVERLAY 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES KEYMAP B M VAULT ELEC TIMBERLINE RD NORTH EXISTING 80' ROW EXISTING 100' ROW ESMT. 50' - 11' TRAVEL 11' TRAVEL 5' WALK 8' BIKE 8' PKWY 8' PKWY 9' UTIL. ESMT. MINOR COLLECTOR STREET SECTION 5' WALK 8' BIKE 50' HALF ROW CS3 CROSS-SECTIONS STREET 3 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 2-02: East side of Timberland Road, 1/2 mile north of Trilby Road, on the middle concrete pad to an electric box. Elevation: 4964.37 City of Fort Collins Benchmark 16-01: South side of Willow Springs Way approx. 50 ft. west of the intersection of Willow Springs Way and Timberline Road on the southwest corner of a storm inlet. Elevation: 4956.98 Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datum. If NGVD29 Unadjusted datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.19 Basis of Bearings The Basis of Bearings is the East line of the Northeast Quarter of Section 11, as bearing North xx° xx' xx" West (assumed bearing) as monumented on drawing. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: N.A. CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Preliminary Drainage and Erosion Control Report for Hansen Property dated September 12, 2017 by Northern Engineering Services, Inc., shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal box and tracer wire test lid per City Water Detail 25. CS2 CONSTRUCTION NOTES GENERAL AND 2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com 212 N. Wahsatch Ave., Suite 301 Colorado Springs, Colorado 80903 (719) 635-3200 SHEET INDEX ENGINEER ING N O R T H E RN ENGINEER ING N O R T H E RN UTILITY CONTACT LIST: * UTILITY COMPANY PHONE NUMBER 1 CS1 COVER SHEET 2 CS2 GENERAL AND CONSTRUCTION NOTES 3 CS3 STREET CROSS-SECTIONS 4 EX1 EXISTING CONDITIONS AND DEMOLITION PLAN 5 OU1 OVERALL UTILITY PLAN 6-10 U1-U5 UTILITY PLAN 11 OG1 OVERALL GRADING PLAN 12-16 G1-G5 GRADING PLAN 17-20 R1-R4 STREET A PLAN AND PROFILE 21-23 R5-R7 STREET B PLAN AND PROFILE 24 R8 STREET C PLAN AND PROFILE 25 R9 STREET D & COMMERCIAL CONNECTION PLAN AND PROFILE 26-27 R10-R11 ZEPHYR ROAD PLAN AND PROFILE 28-30 R12-R14 TIMBERLINE ROAD PLAN AND PROFILE 31-32 R15-R16 STRIPING PLAN 33 HC1 HORIZONTAL CONTROL PLAN 34 INT1 INTERSECTION DETAILS 35 DR1 OVERALL DRAINAGE EXHIBIT A TRACT OF LAND LOCATED IN THE EAST HALF OF SECTION 7, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO HANSEN SUBDIVISION PRELIMINARY UTILITY PLANS FOR OWNER/APPLICANT SITE ENGINEER SURVEYOR GAS----------------- Xcel Energy---------------------------------Stephanie Rich (970) 225-7828 ELECTRIC-------- City of Fort Collins Light & Power----- Jim Spaulding (970) 416-2772 CABLE------------- Comcast------------------------------------- Don Kapperman (970) 567-0245 TELECOM.--------CenturyLink Local Network------------- Robert Rulli (970) 490-7503 WATER------------ City of Fort Collins Utilities--------------Shane Boyle (970) 221-6339 WASTEWATER--City of Fort Collins------------------------ Shane Boyle (970) 221-6339 STORMWATER- City of Fort Collins Utilities--------------Glen Schlueter (970) 224-6065 SANITATION----- City of Fort Collins Utilities--------------Shane Boyle (970) 221-6339 * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. Kristin Turner TB Group 444 Mountain Avenue Berthoud, Colorado 80513 (970) 532-5891 PLANNER/ LANDSCAPE ARCHITECT PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 2-02: East side of Timberland Road, 1/2 mile north of Trilby Road, on the middle concrete pad to an electric box. Elevation: 4964.37 City of Fort Collins Benchmark 16-01: South side of Willow Springs Way approx. 50 ft. west of the intersection of Willow Springs Way and Timberline Road on the southwest corner of a storm inlet. Elevation: 4956.98 Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datum. If NGVD29 Unadjusted datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.19 Basis of Bearings The Basis of Bearings is the East line of the Northeast Quarter of Section 11, as bearing North xx° xx' xx" West (assumed bearing) as monumented on drawing. PROJECT BENCHMARKS: Sheet of 35 HANSEN SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com