RE: 805 Remington Extra Occupancy Rental House, BDR170014, Round Number 1
Comment Summary:
Department: Forestry
Contact: Molly Roche, , mroche@fcgov.com
Topic: Landscape Plans
08/23/2017:
If any existing trees will be impacted, please contact City Forestry to schedule an
on-site meeting to obtain tree inventory and mitigation information.
Comment Number: 1 Comment Originated: 08/23/2017
Department: PFA
Contact: Cal Sheesley, 970-416-2599, csheesley@poudre-fire.org
Topic: General
Please see the following summary of comments from City staff and outside reviewing agencies for
your submittal of the above referenced project. If you have questions about any comments, you may
contact the individual commenter or direct your questions through the Project Planner, Meaghan
Overton, at 970-416-2283 or moverton@fcgov.com.
Page 1 of 4
08/23/2017: FIRE LANES
Fire access is required to within 150' of all exterior portions of any building as
measured by an approved route around the perimeter. For the purposes of this
section, fire access cannot be measured from an arterial road (Remington). When
measured from Plum, the house is roughly 40' out of perimeter access at the
southwest corner of the house. Considering the size, scope and existing street
conditions of the project, the 40' deficiency will not be enforced at this time.
Code language follows:
> IFC 503.1.1: Approved fire Lanes shall be provided for every facility, building or
portion of a building hereafter constructed or moved into or within the jurisdiction.
The fire apparatus access road shall comply with the requirements of this section
and shall extend to within 150 feet of all portions of the facility and all portions of the
exterior walls of the first story of the building as measured by an approved route
around the exterior of the building or facility. When any portion of the facility or any
portion of an exterior wall of the first story of the building is located more than 150
feet from fire apparatus access, the fire code official is authorized to increase the
dimension if the building is equipped throughout with an approved, automatic
fire-sprinkler system.
Comment Number: 1 Comment Originated: 08/23/2017
08/23/2017: WATER SUPPLY
Hydrant spacing and flow must meet minimum requirements based on type of
occupancy. A hydrant is required within 400' of any Residential Building as
measured along an approved path of vehicle travel. The hydrant located at the
northwest corner of Plum and Remington appears to meet hydrant location
requirements at 200' from the existing building.
Code language follows:
RESIDENTIAL REQUIREMENTS
> IFC 507.5 and PFA Policy: Within the Urban Growth Area, hydrants to provide
1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the
building, on 800-foot centers thereafter.
Comment Number: 2 Comment Originated: 08/23/2017
08/23/2017: PREMISE IDENTIFICATION: ADDRESS POSTING & WAYFINDING
The address shall be posted on the existing structure in accordance with the code
language below. Per Google Earth, it is unclear if the existing building currently
meets this requirement.
Code language provided below.
> IFC 505.1: New and existing buildings shall have approved address numbers,
building numbers or approved building identification placed in a position that is plainly
legible, visible from the street or road fronting the property, and posted with a
minimum of six-inch numerals on a contrasting background. Where access is by
means of a private road and the building cannot be viewed from the public way, a
monument, pole or other sign or means shall be used to identify the structure.
Comment Number: 3 Comment Originated: 08/23/2017
Department: Planning Services
Contact: Meaghan Overton, 970-416-2283, moverton@fcgov.com
Page 2 of 4
Topic: General
08/17/2017: Please show the location and number of bicycle parking spaces on the
site plan. One space per bedroom is required. The rack must be a permanent
(anchored, not freestanding) fixture.
Comment Number: 1 Comment Originated: 08/17/2017
08/17/2017: Is the home owner-occupied? If so, an additional parking space will be
required, as will an additional 400 square feet of habitable floor space.
Comment Number: 2 Comment Originated: 08/17/2017
08/17/2017: Please show the dimensions of the parking spaces in the parking area
off the alley. It appears that there may not be enough room for residents to access
the door to the back yard from the parking area if all three spaces are occupied.
Consider adding wheel stops for the parking spaces to ensure access to the gate.
Comment Number: 3 Comment Originated: 08/17/2017
08/17/2017: Please add an owners’ signature block and a signature block for the
Planning Director to the final site plan.
Comment Number: 4 Comment Originated: 08/17/2017
Department: Stormwater Engineering
Contact: Dan Mogen, 970-224-6192, dmogen@fcgov.com
Topic: General
08/14/2017: No proposed site changes were shown in this submittal; therefore, no
requirements apply at this time. If future submittals include site or grading changes
that are not shown on these plans, please contact Dan Mogen in Water Utilities
Engineering at (970)224-6192 or dmogen@fcgov.com to coordinate and determine
what requirements, if any, will apply.
Comment Number: 1 Comment Originated: 08/14/2017
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
Topic: Erosion Control
08/21/2017: No Comment from Erosion Control. Based upon the submitted Erosion
Control Materials it has been determined that this site; disturbs less than 10,000 sq.
ft., is not in a sensitive area, has no steep slopes (greater than 3H:1V), and is not in
a larger development under construction. Therefore, no submittal of Erosion Control
Materials are needed at this time. The site however, still must be swept and
maintained to prevent dirt, saw cuttings, concrete wash, trash & debris, landscape
materials and other pollutants from entering the storm sewer at all times in
accordance with City Code 26-498 or erosion and sediment control measures will
be required of the site. Near by area inlets should be protected as a good
preventative practice. If issues arrise when pulling applicable building permits please
email erosion@fcgov.com to ease getting these signed off. Current Erosion
Control Materials Submitted do not meet requirements. The erosion control
requirements are in the Stormwater Design Criteria under the Amendments of
Volume 3 Chapter 7 Section 1.3.3. a copy of the erosion control requirements can
be found at www.fcgov.com/eroison. If you need clarification concerning the
Erosion Control Material Requirements or Comments presented above please
contact myself. Jesse Schlam (970) 224-6015 jschlam@fcgov.com
Comment Number: 2 Comment Originated: 08/21/2017
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: General
Page 3 of 4
08/22/2017: EXISTING CONDITIONS: There are line over text issues. See redlines.
Comment Number: 1 Comment Originated: 08/22/2017
Department: Zoning
Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com
Topic: General
08/25/2017: Zoning has no additional comments from those already stated by
Planning.
Comment Number: 1 Comment Originated: 08/25/2017