Loading...
HomeMy WebLinkAboutJOHNSON DRIVE APARTMENTS - PDP - PDP170034 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTPRELIMINARY DRAINAGE REPORT Johnson Drive Apartments Fort Collins, Colorado September 6, 2017 Prepared for: Next Chapter Properties 217 S. Neil Street, Suite B Champaign IL, 61820 Prepared by: 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 Phone: 970.221.4158 Fax: 970.221.4159 www.northernengineering.com Project Number: 1285-001  This Drainage Report is consciously provided as a PDF. Please consider the environment before printing this document in its entirety. When a hard copy is absolutely necessary, we recommend double-sided printing. September 6, 2017 City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80521 RE: Preliminary Drainage Report for Johnson Drive Apartments Dear Staff: Northern Engineering is pleased to submit this Preliminary Drainage Report for your review. This report has been prepared in accordance with the City of Fort Collins Stormwater Criteria Manual (FCSCM) and the Urban Drainage and Flood Control District (UDFCD) Urban Storm Drainage Criteria Manual and serves to document the stormwater impacts associated with the proposed Johnson Drive Apartments project. We understand that review by the City of Fort Collins is to assure general compliance with standardized criteria. If you should have any questions as you review this report, please feel free to contact us. Sincerely, NORTHERN ENGINEERING SERVICES, INC. Cody Snowdon, PE Blaine Mathisen Project Manager Project Engineer Johnson Drive Apartments Preliminary Drainage Report TABLE OF CONTENTS I. GENERAL LOCATION AND DESCRIPTION ................................................................... 1 A. Location ............................................................................................................................................. 1 B. Description of Property ..................................................................................................................... 2 C. Floodplain.......................................................................................................................................... 3 II. DRAINAGE BASINS AND SUB-BASINS ....................................................................... 5 A. Major Basin Description .................................................................................................................... 5 B. Sub-Basin Description ....................................................................................................................... 5 III. DRAINAGE DESIGN CRITERIA ................................................................................... 7 A. Regulations........................................................................................................................................ 7 B. Four Step Process .............................................................................................................................. 7 C. Development Criteria Reference and Constraints ............................................................................ 8 D. Hydrological Criteria ......................................................................................................................... 8 E. Hydraulic Criteria .............................................................................................................................. 8 F. Floodplain Regulations Compliance .................................................................................................. 9 G. Modifications of Criteria ................................................................................................................... 9 IV. DRAINAGE FACILITY DESIGN .................................................................................... 9 A. General Concept ............................................................................................................................... 9 B. Specific Details ................................................................................................................................ 10 V. CONCLUSIONS ...................................................................................................... 11 A. Compliance with Standards ............................................................................................................ 11 B. Drainage Concept ............................................................................................................................ 12 References ....................................................................................................................... 13 APPENDICES: APPENDIX A – Hydrologic Computations APPENDIX B – Hydraulic Computations B.1 – Storm Sewers (Future) B.2 – Inlets (Future) B.3 – Detention Facilities APPENDIX C – Water Quality Design Computations APPENDIX D – Erosion Control Report APPENDIX E – Soils Resource Report Johnson Drive Apartments Preliminary Drainage Report LIST OF TABLES AND FIGURES: Figure 1 Vicinity Map .......................................................................................................... 1 Figure 2 Aerial Photograph ................................................................................................... 2 Figure 3 Proposed Site Plan ................................................................................................. 3 Figure 4 FEMA Map ............................................................................................................ 4 Figure 5 City Floodplain Mapping .......................................................................................... 5 MAP POCKET: C4.00 – Proposed Drainage Exhibit Historic Drainage Exhibit Johnson Drive Apartments Preliminary Drainage Report 1 I. GENERAL LOCATION AND DESCRIPTION A. Location 1. Vicinity Map Figure 1 Vicinity Map 2. Johnson Drive Apartments project site is located in the replat of lots 13, 14, 15, 16, and 17 Spring Court Subdivision which is located in the northeat quarter of Section 23, Township 7 North, Range 69 West of the 6th Principal Meridian, City of Fort Collins, County of Larimer, State of Colorado. 3. The project site is located at 255 Johnson Drive at southwest corner of the intersection of Johnson Drive and Spring Court. The property is bounded to the north by Johnson Drive and further north by Spring Creek, to the east by Spring Court, to the south by and irrigation lateral and to the west by BNSF Railway and the Max route. 4. The project site lies within the Spring Creek Basin. The project site has historically drained towards Spring Court and Johnson Drive via overland flow from south to northeast. The site must provide current City Low-Impact Design (LID) requirements and water quality treatment as well. Water quality treatment methods are described Johnson Drive Apartments Preliminary Drainage Report 2 in further detail below. 5. As this is an in-fill site, the area surrounding the property is fully developed. 6. There are no off-site flows that enter the project area. B. Description of Property 1. Johnson Drive Apartments project is approximately 2.80 net acres. Figure 2 Aerial Photograph 2. There are currently five properties being utilized for this project; one commercial lot (Self-Storage) and four residential lots. The existing commercial lot routes stormwater via overland and gutter flow and releases undetained into Johnson Drive. Once in Johnson Drive, stormwater travels via gutter flow to the east where it is intercepted by an existing inlet and conveyed directly to Spring Creek. The four residential lots route stormwater via overland flow and releases undetained into Spring Court. Once in Spring Court, stormwater travel via gutter flow to the north to Johnson Drive, with the ultimate destination being Spring Court. The overall existing impervious area located within in the four properties is 76,857 sq. ft. and was released undetained. There are currently no water quality measures located on-site. 3. According to the United States Department of Agriculture (USDA) Natural Resources Conservation Service (NRCS) Soil Survey, the site consists of Altvan-Satanta and Kim loams, which fall into Hydrologic Soil Groups B. The NRCS soils report is provided in Appendix E. 4. The proposed development is primarily composed of a proposed student housing building. Associated site work that will be constructed with this project include water services, sanitary sewer services, storm sewer, landscaped swales and walls, and sidewalks along the north, south and east side of the building. Current City Low- Impact Design (LID) requirements will be implemented with the project, and will consist of sand filter, which is further discussed in Section IV, below. Johnson Drive Apartments Preliminary Drainage Report 3 Figure 3 Proposed Site Plan 5. There are no known irrigation laterals crossing the site. There is an irrigation lateral bordering the south side of the property. 6. The project site is within a General Commercial District (C-G). The proposed use is permitted within this zone district. C. Floodplain 1. The project site is encroached by the FEMA designated 100- Year High Risk Flood Fringe according to FIRM Panel 08069C87G for Larimer County, dated May 2, 2012. Currently, this area is under review by FEMA which will be adopting the recommendations set forth by the “Letter of Map Revision Application For The Mason Street Transportation Corridor Crossing Of Spring Creek”, prepared by Anderson Consulting Engineer, Inc. on August 10th 2016. This application process is in the latter stages and the FIRM map will be updated per the approved recommendations from Anderson Consulting Engineers, Inc. Johnson Drive Apartments Preliminary Drainage Report 4 2. Development is allowed within the flood fringe. It should be noted that the portion of the structure that will be constructed within the floodplain with the development of Johnson Drive Apartments will be elevated 18” above the Base Flood Elevation at all opening and flood proofing will not be required. Figure 4 FEMA Map Johnson Drive Apartments Preliminary Drainage Report 5 Figure 5 City Floodplain Mapping II. DRAINAGE BASINS AND SUB-BASINS A. Major Basin Description 1. The project site lies within the Spring Creek Basin. Detention requirements for this site are to detain the difference between the 100-yr developed flow rate and the historic 100-yr release of all existing impervious area and 2-yr release rate from the existing landscaping areas. The project is composed of five different lots, one is a commercial lot and the other four are single-family residential lots. Historically, the lots sheet flow into the surrounding streets undetained. However, Johnson Drive Apartments will release at a reduced historic rate and will also provide water quality. The proposed release rate will be reduced to summation of the historic 2-year event within the existing landscape areas and the historic 100-year event within all the existing impervious areas. Water quality will be provided for all the paved areas via a sand filter within the building. All other water quality will be provided by sheet flowing across landscape areas. 2. There are no previous drainage studies for the area associated with Johnson Drive Apartments project site. B. Sub-Basin Description Johnson Drive Apartments historically drains overland from south to north except for the southwest corner of the site which is picked up by an irrigation lateral running west to east. Runoff from the site has historically flowed overland north towards Spring Creek and eventually enters the Cache La Poudre. Johnson Drive Apartments Preliminary Drainage Report 6 Basin HW1 Pervious Historic Basin HW1 Pervious is 0.18 acres and is roughly the western 2/3 of the property, and it is only comprised of landscaping area. Runoff generated in this basin historically sheet flows north into Johnson Drive. Once in Johnson Drive runoff will be conveyed west to east via curb and gutter until it enters a curb inlet and is further conveyed to Spring Creek. Basin HW1 Pervious has a 2-yr runoff of 0.06 cfs. Basin HW1 Impervious Historic Basin HW1 Impervious is 1.56 acres and is roughly the western 2/3 of the property, and it is only comprised of the paved and roof areas associated with Johnson Drive Storage. Runoff generated in this basin historically sheet flows north into Johnson Drive. Once in Johnson Drive runoff will be conveyed west to east via curb and gutter until it enters a curb inlet and is further conveyed to Spring Creek. Basin HW1 Impervious has a 100-yr runoff of 15.48 cfs. Overall Basin HW is 1.73 acres and has a combined release rate of 15.54 cfs (0.06 cfs + 15.48 cfs) from Basins HW1 Pervious 2-year event and HE1 Impervious 100- year event. Basin HE1 Pervious Historic Basin HE1 Pervious is 0.60 acres and is roughly the eastern 1/3 of the property, and it is only comprised of landscaping area. Runoff generated in this basin historically sheet flows directly into Spring Court and is then conveyed north via curb and gutter until it enters a curb inlet and is conveyed to Spring Creek. Basin HE1 Pervious has a 2-yr runoff of 0.15 cfs. Basin HE1 Impervious Historic Basin HE1 Impervious is 0.21 acres and is roughly the eastern 1/3 of the property, and it is comprised of the paved sidewalks and roof areas. Runoff generated in this basin historically sheet flows directly into Spring Court and is then conveyed north via curb and gutter until it enters a curb inlet and is conveyed to Spring Creek. Basin HE1 Impervious has a 100-yr runoff of 2.08 cfs. Overall Basin HE is 0.20 acres and has a combined release rate of 2.22 cfs (0.15 cfs + 2.08 cfs) from Basins HE1 Pervious 2-year event and HE1 Impervious 100-year event. Basin HS1 Pervious Historic Basin HS1 Pervious is 0.27 acres and is situated in the southwest corner of the project site. Runoff generated in this area will sheet flow into an existing irrigation lateral that runs west to east. There is also a small detention pond in this area that is serving the property to the south of the project site. This area will remain untouched during the development of Johnson Drive Apartments. Basin HW1 Pervious has a 2-yr runoff of 0.11 cfs. Basin HS1 Impervious Historic Basin HS1 Impervious is 0 acres because it is all vegetated. Basin HW1 Impervious has a 100-yr runoff of 0 cfs. Overall Basin HS1 is 0.27 acres and has a combined release rate of 0.11 cfs (0.11 cfs + 0 cfs) from Basins HS1 Pervious and HS1 Impervious. Therefore, the overall historic release rate from the site is 17.88 cfs (15.54 cfs + 2.22 cfs + 0.11 cfs). However, due to uncapturable flows from Johnson Drive Apartments, which is Johnson Drive Apartments Preliminary Drainage Report 7 discussed in Section IV.A, the allowable release rate is reduced to 13.09 cfs. 1. A more detailed description of the project’s proposed drainage patterns follows in Section IV.A.4. A full-size copy of the Historic and Proposed Drainage Exhibits can be found in the Map Pocket at the end of this report. III. DRAINAGE DESIGN CRITERIA A. Regulations There are no optional provisions outside of the FCSCM proposed with the Johnson Drive Apartments project. B. Four Step Process The overall stormwater management strategy employed with the Johnson Drive Apartments project utilizes the “Four Step Process” to minimize adverse impacts of urbanization on receiving waters. The following is a description of how the proposed development has incorporated each step. Step 1 – Employ Runoff Reduction Practices Several techniques have been utilized with the proposed development to facilitate the reduction of runoff peaks, volumes, and pollutant loads as the site is redeveloped from the current use by implementing multiple Low-Impact Development (LID) strategies including: Providing as much vegetated open areas as possible along the east, west and south portion of the site to reduce the overall impervious area and to minimize directly connected impervious areas (MDCIA). Selecting a site that has been previously developed to reduce development impacts. Routing flows, to the extent feasible, through a stormwater detention vault located internal to the building for water quality purposes. Stormwater will be routed through a sand filter to increase filtration. Providing on-site detention to increase time of concentration, and reduce loads on downstream storm infrastructure. Routing runoff from the roof directly into the sand filter. Step 2 – Implement BMPs That Provide a Water Quality Capture Volume (WQCV) with Slow Release The efforts taken in Step 1 will facilitate the reduction of runoff; however, urban development of this intensity will still generate stormwater runoff that will require additional BMPs and water quality. The stormwater runoff from the site will be intercepted and treated using an internal stormwater vault with a water quality capture volume. Step 3 – Stabilize Drainageways There are no major drainageways within the subject property. While this step may not seem applicable to proposed development, the project indirectly helps achieve stabilized drainageways nonetheless. By providing detention and water quality treatment where none previously existed, sediment and flash flows with erosion potential are removed from downstream drainageway systems. Furthermore, this project will pay one-time stormwater Johnson Drive Apartments Preliminary Drainage Report 8 development fees, as well as ongoing monthly stormwater utility fees, both of which help achieve City-wide drainageway stability. Step 4 – Implement Site Specific and Other Source Control BMPs. The proposed project includes one multi-story building, covered parking areas within the structure, retaining walls, and pedestrian sidewalks, all of which will require the need for site specific source controls including: A localized trash enclosure placed within the building. The proposed development will provide LID features within the stormwater vault internal to the building to provide enhanced water quality. The Sand Filter is designed to capture the first flush storm event; thus, eliminating sources of potential pollution previously left exposed to weathering and runoff processes. C. Development Criteria Reference and Constraints 1. There are no known drainage studies for the existing property. 2. The subject property is a redevelopment project and is surrounded by currently developed properties. As such, several constraints have been identified during the course of this analysis that will impact the proposed drainage system including: Existing elevations along the north, south, east, and west property lines will be maintained. Overall drainage patterns of the existing site will be maintained. Release rates can not adversely impact existing infrastructure. D. Hydrological Criteria 1. The City of Fort Collins Rainfall Intensity-Duration-Frequency Curves, as depicted in Figure RA-16 of the FCSCM, serve as the source for all hydrologic computations associated with this development. Tabulated data contained in Table RA-7 has been utilized for Rational Method runoff calculations. 2. The Rational Method has been employed to compute stormwater runoff utilizing coefficients contained in Tables RO-11 and RO-12 of the FCSCM. 3. The Rational Formula-based Modified Federal Aviation Administration (FAA) procedure has been utilized for detention storage calculations. 4. Two separate design storms have been utilized to address distinct drainage scenarios. The first event analyzed is the “Minor,” or “Initial” Storm, which has a 2-yr recurrence interval. The second event considered is the “Major Storm,” which has a 100-yr recurrence interval. 5. No other assumptions or calculation methods have been used with this development that are not referenced by current City of Fort Collins criteria. E. Hydraulic Criteria 1. As previously noted, the subject property maintains historic drainage patterns. 2. All drainage facilities proposed with the Johnson Drive Apartments project are designed in accordance with criteria outlined in the FCSCM and/or the Urban Drainage and Flood Control District’s (UDFCD) Urban Storm Drainage Criteria Manual. 3. As stated in Section I.C.1, above, the subject property is encroaching a FEMA 100- Year High Risk Flood Fringe. Johnson Drive Apartments Preliminary Drainage Report 9 F. Floodplain Regulations Compliance As previously mentioned, the project site is encroaching a FEMA 100-Year High Risk Flood Fringe along the northwest corner of the property. Development is allowed within the flood fringe pursuant to Chapter 10 of the City of Fort Collins Municipal Code. It should be noted that no structures will be constructed within the floodplain with the development of Johnson Drive Apartments. G. Modifications of Criteria The proposed Johnson Drive Apartments development is not requesting any modifications. IV. DRAINAGE FACILITY DESIGN A. General Concept 1. The main objectives of the Johnson Drive Apartments drainage design are to maintain existing drainage patterns and ensure no adverse impacts to any adjacent properties or existing infrastructure. 2. As previously mentioned, there are no off-site flows draining onto the existing property. Additionally, on-site LID feature will be provided which will enhance downstream water quality. These measures are discussed further below. 3. A list of tables and figures used within this report can be found in the Table of Contents at the front of the document. The tables and figures are located within the sections to which the content best applies. 4. The proposed Johnson Drive Apartments project is has been divided into five (5) major drainage basins, designated as Basins A1, OW1, OS1, OS2, and ON1. Drainage patterns for basins shown on the Proposed Drainage Exhibit are described below. Basin A1 Basin A1 has a net area of 1.668 acres, which corresponds to the entire building footprint. Runoff generated in Basin A1 will be generated by the roof which will then convey the runoff to an internal storm vault via roof leaders. The internal storm vault will also be a sand filter therefore, 100% of the treatable runoff is treated via LID. Basin A1 will provide onsite detention that is required for the runoff volume difference between the 100-year developed inflow rate and the 2-year historic release rate for any net new impervious area. After Basin A1 is detained and treated, it will be conveyed to Spring Creek via ADS pipe. The 100-year flow rate for Basin A1 is 16.59 cfs. Basin OW1 Basin OW1 is located between the proposed apartment building and the Mason Street corridor retaining wall and has a net area of 0.093 acres. This area is all landscaping but due to existing grades this area will be getting free released into Spring Creek via a Nyloplast inline drain that is connected to the outfall pipe of Basin A1. Since Basin OW1 is leaving the site undetained and untreated the overall release rate will be modified to reflect this. The 100-year release rate for Basin OW1 is 0.17 cfs. Johnson Drive Apartments Preliminary Drainage Report 10 Basin OS1 Basin OS1 has a net area of 0.301 acre, and is associated with the Sherwood Irrigation lateral and detention pond that occupy the southwest corner of the site. This area has historically bypassed the site flowing east via the irrigation lateral. Johnson Drive apartments will not be developing anything in this area therefore this runoff will continue to flow east via the irrigation lateral. Because Johnson Drive Apartments is not able to capture and treat this area runoff the max allowable release rate will be reduced to reflect this. The 100-year release rate for Basin OS1 is 1.03 cfs. Basin OS2 Basin OS2 has a net area of 0.30 acres, and is located along the southern edge of the proposed apartment building and northern side of the irrigation lateral. All the runoff generated in Basin OS2 will flow east towards Spring Court via a swale. Runoff generated in Basin OS2 will freely discharge into Spring Court via a concrete chase. Therefore, the max allowable release rate will be reduced to reflect that Basin OS2 is not being detained or treated. The 100-year release rate for Basin OS2 is 0.41 cfs. Basin ON1 Basin ON1 has a net area of 0.48 acres, and is located along the eastern and northern edge of the proposed apartment building. All the flow generated in Basin ON1 will leave the site undetained and untreated via overland flow. The runoff will either enter Spring Court or Johnson Drive. Once in the public right of way the runoff will make its way to an existing inlet near the northeast corner of the intersection of Johnson Drive and Spring Court. From there the runoff will be conveyed to Spring Creek via pipe. The 100-year release rate for Basin ON1 is 3.18 cfs. Max Allowable Release Rate The max allowable release rate for Johnson Drive Apartments is 13.09 cfs. This was calculated by summing up the historic release rates from Basins HW1, HE1, and HS1 2-year pervious and 100-year impervious rates. Following the calculations laid out in Section II.B yields a historic release rate of 17.88 cfs. Due to the Basins OS1, OS2, ON1, and OW1 free releasing off the site the 17.88 cfs was reduced by summation of the aforementioned basins 100-year release rates which is 4.79 cfs. Therefore, the max allowable release rate is 17.88 cfs – 4.79 cfs = 13.09 cfs. B. Specific Details 1. The main drainage problems associated with this project site are the deficiency of existing stormwater infrastructure present, steep existing grades, an existing irrigation lateral running across the site, and FEMA floodplain. Currently the site drains to the northeast. The proposed site will mitigate these issues by instituting the following water quality and detention facilities: Johnson Drive Apartments will be utilizing a sand filter to treat all the runoff generated by Basin A1. The sand filter will be incorporated into the internal storm chamber within the apartment building. Johnson Drive Apartments Preliminary Drainage Report 11 All the free released runoff will be generated by landscaping areas which will provide minimal water quality via grass buffers. 2. Detention Pond Calculations Using the FAA Method to detain Basin A1 with a reduced release rate of 13.09 cfs yields an overall detention volume of 1946 cu. ft. This required volume will be stored in conjunction with the WQCV within the internal storm chamber. 3. Water Quality Results Following UDFCD criteria and using the characteristics from Basin A1 wields an overall water quality capture volume (WQCV) of 2,187 cu. ft. This water quality will be getting provided via sand filter. With the current configuration of the internal stomr chamber the actual WQCV is 2,250 cu. ft. The treated runoff will be conveyed to Spring Creek via HDPE pipe. 4. Below is a breakdown of the LID treatment of the proposed project site. V. CONCLUSIONS A. Compliance with Standards 1. The drainage design proposed with the Johnson Drive Apartments project complies with the City of Fort Collins’ Stormwater Criteria Manual. 2. The drainage design proposed with the Johnson Drive Apartments project complies with the City of Fort Collins’ Master Drainage Plan for the Spring Creek Basin. 3. The project site is encroached by a 100-Year High Floodplain Fringe along the northwest corner of the property. However, the development will not adversely impact any of the downstream infrastructure, as this floodplain is caused by the obstruction of the College Avenue bridge. 4. The drainage plan and stormwater management measures proposed with the Johnson Drive Apartments development are compliant with all applicable State and Federal regulations governing stormwater discharge. Basin ID Basin Impervious Area Treatment Type LID System Area Treated by Percent of Impervious Area A1 1.668 ac. Sand Filter Yes 1.668 ac. 84% OW1 0.000 ac. Grass Buffer No N/A 0% OS1 0.047 ac. Grass Buffer No N/A 0% OS2 0.002 ac. Grass Buffer No N/A 0% ON1 0.271 ac. Grass Buffer No N/A 0% Total 1.988 ac. 1.668 ac. 84% Johnson Drive Apartments Preliminary Drainage Report 12 B. Drainage Concept 1. The drainage design proposed with this project will effectively limit potential damage associated with its stormwater runoff. The total difference in impervious area between historic and proposed conditions is only 9,801 sq. ft., which is only 8,801 sq. ft. above the maximum threshold for detention according to the City of Fort Collins Stormwater Criteria Manual. 2. Johnson Drive Apartments will be releasing at reduced runoff rates from the historic condition to both Johnson Drive and Spring Court; therefore, there will be no downstream impacts from this development. 3. Johnson Drive Apartments will provide water quality for a majority of the site (1.668 acres out of 2.80 acreas) with accepted LID treatments. The remaining portion of the project site will receive water quality by crossing over landscaped areas. The areas receiving water quality via landscaping were uncatchable and only include the perimeter areas along the north, south, east, and west. 4. The proposed Johnson Drive Apartments development will not impact the Master Drainage Plan recommendations for the Spring Creek major drainage basin. Johnson Drive Apartments Preliminary Drainage Report 13 References 1. City of Fort Collins Landscape Design Guidelines for Stormwater and Detention Facilities, November 5, 2009, BHA Design, Inc. with City of Fort Collins Utility Services. 2. Fort Collins Stormwater Criteria Manual, City of Fort Collins, Colorado, as adopted by Ordinance No. 174, 2011, and referenced in Section 26-500 (c) of the City of Fort Collins Municipal Code. 3. Larimer County Urban Area Street Standards, Adopted January 2, 2001, Repealed and Reenacted, Effective October 1, 2002, Repealed and Reenacted, Effective April 1, 2007. 4. Soils Resource Report for Larimer County Area, Colorado, Natural Resources Conservation Service, United States Department of Agriculture. 5. Urban Storm Drainage Criteria Manual, Volumes 1-3, Urban Drainage and Flood Control District, Wright-McLaughlin Engineers, Denver, Colorado, Revised April 2008. Johnson Drive Apartments Preliminary Drainage Report 14 APPENDIX A HYDROLOGIC COMPUTATIONS CHARACTER OF SURFACE: Runoff Coefficient Percentage Impervious Project: Johnson Drive Apartments Streets, Parking Lots, Roofs, Alleys, and Drives: Calculations By: C. Snowdon Asphalt ……....……………...……….....…...……………….………………………………….. 0.95 100% Date: Concrete …….......……………….….……….………………..….………………………………… 0.95 90% Gravel ……….…………………….….…………………………..……………………………….0.15 . 0.50 40% Roofs …….…….………………..……………….…………………………………………….. 0.95 90% Pavers…………………………...………………..…………………………………………….. 0.40 22% Lawns and Landscaping Sandy Soil ……..……………..……………….…………………………………………….. 0.15 0% Clayey Soil ….….………….…….…………..………………………………………………. 0.25 0% 2-year C f = 1.00 100-year C f = 1.25 Basin ID Basin Area (s.f.) Basin Area (ac) Area of Asphalt (ac) Area of Concrete (ac) Area of Roofs (ac) Area of Gravel (ac) Area of Lawns and Landscaping (ac) 2-year Composite Runoff Coefficient 10-year Composite Runoff Coefficient 100-year Composite Runoff Coefficient Composite % Imperv. HW1 75478 1.73 0.86 0.01 0.69 0.00 0.18 0.87 0.87 1.00 86% HE1 35074 0.81 0.00 0.07 0.14 0.00 0.60 0.36 0.36 0.45 23% HS1 11546 0.27 0.00 0.00 0.00 0.00 0.27 0.15 0.15 0.19 0% Total 122098 2.80 0.86 0.09 0.82 0.00 1.04 0.65 0.65 0.82 60% HW1 (Impervious) 67772 1.56 0.86 0.01 0.69 0.00 0.00 0.95 0.95 1.00 96% HW1 (Pervious) 7706 0.18 0.00 0.00 0.00 0.00 0.18 0.15 0.15 0.19 0% HE1 (Impervious) 9085 0.21 0.00 0.07 0.14 0.00 0.00 0.95 0.95 1.00 90% HE1 (Pervious) 25989 0.60 0.00 0.00 0.00 0.00 0.60 0.15 0.15 0.19 0% HS1 (Impervious) 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0% Overland Flow, Time of Concentration: Project: Johnson Drive Apartments Calculations By: Date: Gutter/Swale Flow, Time of Concentration: 0.15 0 Tt = L / 60V Tc = Ti + Tt (Equation RO-2) Velocity (Gutter Flow), V = 20·S½ Velocity (Swale Flow), V = 15·S½ NOTE: C-value for overland flows over grassy surfaces; C = 0.25 Is Length >500' ? C*Cf (2-yr Cf=1.00) C*Cf (10-yr Cf=1.00) C*Cf (100-yr Cf=1.25) Length, L (ft) Slope, S (%) Ti 2-yr (min) Ti 10-yr (min) Ti 100-yr (min) Length, L (ft) Slope, S (%) Velocity, V (ft/s) Tt (min) Length, L (ft) Slope, S (%) Velocity, V (ft/s) Tt (min) 2-yr Tc Rational Method Equation: Project: Johnson Drive Apartments Calculations By: Date: From Section 3.2.1 of the CFCSDDC Rainfall Intensity: hw1 HW1 1.73 5 5 5 0.87 0.87 1.00 2.85 4.87 9.95 4.29 7.33 17.24 he1 HE1 0.81 16 16 15 0.36 0.36 0.45 1.81 3.08 6.62 0.52 0.89 2.38 hs1 HS1 0.27 5 5 5 0.15 0.15 0.19 2.85 4.87 9.95 0.11 0.19 0.49 N/A HW1 (Impervious) 1.56 5 5 5 0.95 0.95 1.00 2.85 4.87 9.95 4.21 7.20 15.48 N/A HW1 (Pervious) 0.18 10 10 10 0.15 0.15 0.19 2.26 3.86 7.88 0.06 0.10 0.26 N/A HE1 (Impervious) 0.21 6 6 5 0.95 0.95 1.00 2.67 4.56 9.95 0.53 0.90 2.08 N/A HE1 (Pervious) 0.60 19 19 18 0.15 0.15 0.19 1.65 2.82 5.92 0.15 0.25 0.66 N/A HS1 (Impervious) 0.00 5 5 5 0.00 0.00 0.00 2.85 4.87 9.95 0.00 0.00 0.00 N/A HS1 (Pervious) 0.27 5 5 5 0.15 0.15 0.19 2.85 4.87 9.95 0.11 0.19 0.49 Total Release = 17.88 HISTORIC RUNOFF COMPUTATIONS Intensity, i2 (in/hr) Intensity, i10 (in/hr) Intensity, i100 (in/hr) Notes C. Snowdon September 6, 2017 Rainfall Intensity taken from the City of Fort Collins Storm Drainage Design Criteria (CFCSDDC), Figure 3.1 Design Point Basin(s) Area, A (acres) 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) Flow, Q2 (cfs) Total allowable release from Basin Hs1 = 0.11 C2 Total allowable release from Basin Hs1 = 2.22 Total allowable release from Basin HN1 = 15.54 Flow, Q10 (cfs) Flow, Q100 (cfs) C10 CHARACTER OF SURFACE: Runoff Coefficient Percentage Impervious Project: Johnson Drive Apartments Streets, Parking Lots, Roofs, Alleys, and Drives: Calculations By: Asphalt ……....……………...……….....…...……………….………………………………….0.. 95 100% Date: Concrete …….......……………….….……….………………..….………………………………… 0.95 90% Gravel ……….…………………….….………………………….0..……………………………….15 0.. 50 40% Roofs …….…….………………..……………….…………………………………………….. 0.95 90% Pavers…………………………...………………..…………………………………………….. 0.40 22% Lawns and Landscaping Sandy Soil ……..……………..……………….…………………………………………….. 0.15 0% Clayey Soil ….….………….…….…………..………………………………………………. 0.25 0% 2-year C f = 1.00 100-year C f = 1.25 Basin ID Basin Area (s.f.) Basin Area (ac) Area of Asphalt (ac) Area of Concrete (ac) Area of Roofs (ac) Area of Gravel (ac) Area of Pavers (ac) Area of Lawns and Landscaping (ac) 2-year Composite Runoff Coefficient 10-year Composite Runoff Coefficient 100-year Composite Runoff Coefficient Composite % Imperv. A1 72641 1.668 0.000 0.000 1.668 0.000 0.000 0.000 0.95 0.95 1.00 90% OW1 4061 0.093 0.000 0.000 0.000 0.000 0.000 0.093 0.15 0.15 0.19 0% OS1 13093 0.301 0.000 0.047 0.000 0.000 0.000 0.254 0.27 0.27 0.34 14% OS2 11338 0.260 0.000 0.000 0.000 0.000 0.000 0.260 0.15 0.15 0.19 0% ON1 20964 0.481 0.105 0.166 0.000 0.000 0.000 0.210 0.60 0.60 0.75 53% TOTAL 122097 2.80 0.105 0.213 1.668 0.000 0.000 0.818 0.72 0.72 0.90 64% Overland Flow, Time of Concentration: Project: Johnson Drive Apartments Calculations By: Date: Gutter/Swale Flow, Time of Concentration: Tt = L / 60V Tc = Ti + Tt (Equation RO-2) Velocity (Gutter Flow), V = 20·S ½ Velocity (Swale Flow), V = 15·S ½ NOTE: C-value for overland flows over grassy surfaces; C = 0.25 Is Length >500' ? C*Cf (2-yr Cf =1.00) C*Cf (10-yr Cf =1.00) C*Cf (100-yr Cf =1.25) Length, L (ft) Slope, S (%) Ti 2-yr (min) Ti 10-yr (min) Ti 100-yr (min) Length, L (ft) Slope, S (%) Velocity, V (ft/s) Tt (min) Length, L (ft) Slope, Rational Method Equation: Project: Johnson Drive Apartments Calculations By: Date: From Section 3.2.1 of the CFCSDDC Rainfall Intensity: a1 A1 1.67 5 5 5 0.95 0.95 1.00 2.85 4.87 9.95 4.52 7.72 16.59 13.09 ow1 OW1 0.09 5 5 5 0.15 0.15 0.19 2.85 4.87 9.95 0.04 0.07 0.17 0.17 os1 OS1 0.30 5 5 5 0.27 0.27 0.34 2.85 4.87 9.95 0.24 0.40 1.03 1.03 os2 OS2 0.26 9 9 8 0.15 0.15 0.19 2.35 4.02 8.38 0.09 0.16 0.41 0.41 on1 ON1 0.48 9 9 7 0.60 0.60 0.75 2.30 3.93 8.80 0.66 1.14 3.18 3.18 Total 17.88 DEVELOPED RUNOFF COMPUTATIONS C100 Design Point Flow, Q100 (cfs) Flow, Q2 (cfs) 10-yr Tc (min) 2-yr Tc (min) C2 Flow, Q10 (cfs) Intensity, i100 (in/hr) Basin(s) C. Snowdon September 6, 2017 Intensity, i10 (in/hr) Rainfall Intensity taken from the City of Fort Collins Storm Drainage Design Criteria (CFCSDDC), Figure 3.1 C10 Area, A (acres) Intensity, i2 (in/hr) 100-yr Tc (min) 100-year Release Rate Q = C f ( C )( i )( A ) Page 6 of 23 D:\Projects\1285-001\Drainage\Hydrology\1285-001_Rational-Calcs.xlsx\Direct-Runoff DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) a1 A1 1.668 0.95 1.00 5.0 5.0 4.52 16.59 ow1 OW1 0.093 0.15 0.19 5.0 5.0 0.04 0.17 os1 OS1 0.301 0.27 0.34 5.0 5.0 0.24 1.03 os2 OS2 0.260 0.15 0.19 8.7 8.4 0.09 0.41 on1 ON1 0.481 0.72 0.75 9.4 7.4 0.66 3.18 DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) hw1 HW1 1.733 0.87 1.00 5.2 5.0 4.29 17.24 he1 HE1 0.805 0.36 0.45 16.3 14.7 0.52 2.38 Page 7 of 23 D:\Projects\1285-001\Drainage\Hydrology\1285-001_Rational-Calcs.xlsx\SUMMARY-TABLE APPENDIX B HYDRAULIC COMPUTATIONS B.1 – Storm Sewers (Future Use) B.2 – Inlets (Future Use) B.3 – Detention Facilities APPENDIX B.1 STORM SEWERS (FOR FUTURE USE) APPENDIX B.2 INLETS (FOR FUTURE USE) APPENDIX B.3 DETENTION FACILITIES Pond No : A1 100-yr 1.00 5.00 min 1946 ft3 1.67 acres 0.045 ac-ft Max Release Rate = 13.09 cfs Time (min) Ft Collins 100-yr Intensity (in/hr) Inflow Volume (ft3) Outflow Adjustment Factor Qav (cfs) Outflow Volume (ft3) Storage Volume (ft3) 5 9.950 4985 1.00 13.09 3927 1058 10 7.720 7735 0.75 9.82 5891 1845 15 6.520 9800 0.67 8.73 7854 1946 20 5.600 11222 0.63 8.18 9818 1405 25 4.980 12475 0.60 7.85 11781 694 30 4.520 13587 0.58 7.64 13745 -157 35 4.080 14309 0.57 7.48 15708 -1399 40 3.740 14990 0.56 7.36 17672 -2682 45 3.460 15601 0.56 7.27 19635 -4034 50 3.230 16182 0.55 7.20 21599 -5416 55 3.030 16698 0.55 7.14 23562 -6864 60 2.860 17194 0.54 7.09 25526 -8331 65 2.720 17715 0.54 7.05 27489 -9774 70 2.590 18166 0.54 7.01 29453 -11286 75 2.480 18637 0.53 6.98 31416 -12779 80 2.380 19078 0.53 6.95 33380 -14301 85 2.290 19504 0.53 6.93 35343 -15839 90 2.210 19930 0.53 6.91 37307 -17377 95 2.130 20275 0.53 6.89 39270 -18995 100 2.060 20641 0.53 6.87 41234 -20592 105 2.000 21042 0.52 6.86 43197 -22155 110 1.940 21383 0.52 6.84 45161 -23778 115 1.890 21778 0.52 6.83 47124 -25346 120 1.840 22124 0.52 6.82 49088 -26963 *Note: Using the method described in Urban Storm Drainage Criteria Manual Volume 2. A = Tc = Project Location : Design Point C = Design Storm DETENTION POND CALCULATION; MODIFIED FAA METHOD w/ Ft Collins IDF Input Variables Results Required Detention Volume Fort Collins, Colorado APPENDIX C WATER QUALITY DESIGN COMPUTATIONS Sheet 1 of 2 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia Ia = 90.0 % (100% if all paved and roofed areas upstream of sand filter) B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 0.900 C) Water Quality Capture Volume (WQCV) Based on 12-hour Drain Time WQCV = 0.36 watershed inches WQCV= 0.9 * (0.91* i3 - 1.19 * i2 + 0.78 * i) D) Contributing Watershed Area (including sand filter area) Area = 72,641 sq ft E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = 2,187 cu ft VWQCV = WQCV / 12 * Area F) For Watersheds Outside of the Denver Region, Depth of d6 = 0.43 in Average Runoff Producing Storm G) For Watersheds Outside of the Denver Region, VWQCV OTHER = 2,187 cu ft Water Quality Capture Volume (WQCV) Design Volume H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER = cu ft (Only if a different WQCV Design Volume is desired) 2. Basin Geometry A) WQCV Depth DWQCV = 1.5 ft B) Sand Filter Side Slopes (Horizontal distance per unit vertical, Z = 0.00 ft / ft 4:1 or flatter preferred). Use "0" if sand filter has vertical walls. C) Mimimum Filter Area (Flat Surface Area) AMin = 486 sq ft D) Actual Filter Area AActual = 1500 sq ft E) Volume Provided VT = 2250 cu ft 3. Filter Material 4. Underdrain System A) Are underdrains provided? B) Underdrain system orifice diameter for 12 hour drain time i) Distance From Lowest Elevation of the Storage y = 1.0 ft Volume to the Center of the Orifice ii) Volume to Drain in 12 Hours Vol12 = 2,187 cu ft iii) Orifice Diameter, 3/8" Minimum DO = 1 - 3 / 16 in Johnson Drive Apartments - Basin A1 Fort Collins, CO Design Procedure Form: Sand Filter (SF) Cody Snowdon Northern Engineering September 6, 2017 Choose One Choose One 18" CDOT Class C Filter Material Other (Explain): YES NO WQ - Basin A1 - UD-BMP_v3.03.xlsm, SF 9/6/2017, 10:01 AM Sheet 2 of 2 Designer: Company: Date: Project: Location: 5. Impermeable Geomembrane Liner and Geotextile Separator Fabric A) Is an impermeable liner provided due to proximity of structures or groundwater contamination? PROVIDE A 30 MIL (MIN) PVC GEOMEMBRANE PER TABLE SF-4 WITH SEPARATOR FABRIC (PER TABLE SF-3) ABOVE IT. PROVIDE SEPARATOR FABRIC BELOW THE GEOMEMBRANE AS WELL IF SUBGRADE IS ANGULAR OR COULD OTHERWISE PUNCTURE THE GEOMEMBRANE. 6-7. Inlet / Outlet Works A) Describe the type of energy dissipation at inlet points and means of conveying flows in excess of the WQCV through the outlet Notes: Design Procedure Form: Sand Filter (SF) Cody Snowdon Northern Engineering September 6, 2017 Johnson Drive Apartments - Basin A1 Fort Collins, CO Choose One YES NO WQ - Basin A1 - UD-BMP_v3.03.xlsm, SF 9/6/2017, 10:01 AM APPENDIX D EROSION CONTROL REPORT A comprehensive Erosion and Sediment Control Plan (along with associated details) will be included with the final construction drawings. It should be noted, however, that any such Erosion and Sediment Control Plan serves only as a general guide to the Contractor. Staging and/or phasing of the BMPs depicted, and additional or different BMPs from those included may be necessary during construction, or as required by the authorities having jurisdiction. It shall be the responsibility of the Contractor to ensure erosion control measures are properly maintained and followed. The Erosion and Sediment Control Plan is intended to be a living document, constantly adapting to site conditions and needs. The Contractor shall update the location of BMPs as they are installed, removed or modified in conjunction with construction activities. It is imperative to appropriately reflect the current site conditions at all times. The Erosion and Sediment Control Plan shall address both temporary measures to be implemented during construction, as well as permanent erosion control protection. Best Management Practices from the Volume 3, Chapter 7 – Construction BMPs will be utilized. Measures may include, but are not limited to, silt fencing along the disturbed perimeter, gutter protection in the adjacent roadways and inlet protection at proposed storm inlets. Vehicle tracking control pads, spill containment and clean-up procedures, designated concrete washout areas, dumpsters, and job site restrooms shall also be provided by the Contractor. Grading and Erosion Control Notes can be found on Sheet C0.01 and C3.00 of the Utility Plans. The Utility Plans will also contain a full-size Erosion Control Plan, as well as a separate sheet dedicated to Erosion Control Details. In addition to this report and the referenced plan sheets, the Contractor shall be aware of, and adhere to, the applicable requirements outlined in any existing Development Agreement(s) of record, as well as the Development Agreement, to be recorded prior to issuance of the Development Construction Permit. Also, the Site Contractor for this project will be required to secure a Stormwater Construction General Permit from the Colorado Department of Public Health and Environment (CDPHE), Water Quality Control Division – Stormwater Program, before commencing any earth disturbing activities. Prior to securing said permit, the Site Contractor shall develop a comprehensive StormWater Management Plan (SWMP) pursuant to CDPHE requirements and guidelines. The SWMP will further describe and document the ongoing activities, inspections, and maintenance of construction BMPs. MAP PACKET st st st st st D B M D ST X X X X X X X X X X JOHNSON DRIVE SPRING COURT BURLINGTON NORTHERN RAILWAY AND MAX GUIDEWAY PORTION OF LOT 3, BANK CENTER SQUARE 2' CONCRETE PAN a1 FFE=89.50 EXISTING DRAINAGE DITCH EXISTING STORM INLET EXISTING STORM MH EXISTING 12" ADS 4:1 9:1 5:1 5:1 4:1 43:1 6:1 7:1 7:1 17:1 5:1 4:1 11:1 6:1 (1.7:1) (1.7:1) (1.6:1) (1.5:1) (1.5:1) (1.4:1) (2.2:1) BFE=4985.17 BFE=4986.17 BFE=4987.17 100-YEAR FLOODPLAIN A1 OS1 OW1 ON1 OS2 ow1 os2 No. Revisions: By: Date: REVIEWED BY: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 09/06/2017 PROJECT: 1285-001 Sheet of 11 JOHNSON DRIVE APARTMENTS These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 C4.00 DRAINAGE EXHIBIT LEGEND: RUNOFF SUMMARY: PROJECT BOUNDARY DESIGN POINT PROPOSED STORM SEWER EXISTING STORM INLET PROPOSED CURB & GUTTER 1. REFER TO "PRELIMINARY DRAINAGE REPORT FOR JOHNSON DRIVE APARTMENTS DATED 09/05/2017" FOR ADDITIONAL INFORMATION BASE FLOOD ELEVATION (BFE) EXISTING STORM MANHOLE D A2 a3 (4:1) PROPOSED MAJOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED SLOPE (RISE:RUN) 4:1 DRAINAGE BASIN MINOR/MAJOR COEFF. DRAINAGE BASIN ID EXISTING SLOPE (RISE:RUN) EXISTING CONCENTRATED FLOW PROPOSED CONCENTRATED FLOW PROPOSED OVERLAND FLOW NOTES: 100-YEAR FLOODPLAIN EXISTING STORM SEWER ST BASIN ID TOTAL AREA (acres) C2 C100 Q2 (cfs) Q100 (cfs) A1 1.668 0.95 1.00 4.52 16.59 OW1 0.093 0.15 0.19 0.04 0.17 OS1 0.301 0.27 0.34 0.24 1.03 OS2 0.260 0.15 0.19 0.09 0.41 ON1 0.481 0.72 0.75 0.66 3.18 FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION 11 1285-001 Johnson Drive Apartments Project Number : Project Name : Pond A1 Page 1 of 1 1285-001_Pond A1_DetentionVolume_FAAModified Method.xls S (%) Velocity, V (ft/s) Tt (min) 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) a1 A1 No 0.95 0.95 1.00 N/A N/A N/A N/A 209 0.50% 1.41 2.5 N/A N/A N/A 5 5 5 ow1 OW1 No 0.15 0.15 0.19 20 25.00% 2.7 2.7 2.6 N/A N/A N/A 171 2.92% 2.56 1.1 5 5 5 os1 OS1 No 0.27 0.27 0.34 24 45.92% 2.1 2.1 1.9 N/A N/A N/A N/A N/A N/A 5 5 5 os2 OS2 No 0.15 0.15 0.19 34 5.11% 6.0 6.0 5.8 N/A N/A N/A 335 2.00% 2.12 2.6 9 9 8 on1 ON1 No 0.60 0.60 0.75 81 2.11% 6.6 6.6 4.6 264 0.59% 1.54 2.9 N/A N/A N/A 9 9 7 DEVELOPED TIME OF CONCENTRATION COMPUTATIONS Gutter/Internal Building Flow Swale Flow Design Point Basin Overland Flow C. Snowdon September 6, 2017 Time of Concentration (Equation RO-4) ( ) 3 1 1 . 87 1 . 1 * S C Cf L Ti = − Page 5 of 23 D:\Projects\1285-001\Drainage\Hydrology\1285-001_Rational-Calcs.xlsx\Tc-10-yr_&_100-yr DEVELOPED COMPOSITE % IMPERVIOUSNESS AND RUNOFF COEFFICIENT CALCULATIONS Runoff Coefficients are taken from the City of Fort Collins Storm Drainage Design Criteria and Construction Standards, Table 3-3. % Impervious taken from UDFCD USDCM, Volume I. 10-year Cf = 1.00 September 6, 2017 **Soil Classification of site is Sandy Loam** C. Snowdon Page 4 of 23 D:\Projects\1285-001\Drainage\Hydrology\1285-001_Rational-Calcs.xlsx\C-Values C100 Q = C f ( C )( i )( A ) Page 3 of 23 D:\Projects\1285-001\Drainage\Hydrology\1285-001_Rational-Calcs.xlsx\Hist-Direct-Runoff (min) 10-yr Tc (min) 100-yr Tc (min) hw1 HW1 No 0.87 0.87 1.00 35 5.00% 1.5 1.5 0.6 425 0.90% 1.90 3.7 N/A N/A N/A 5 5 5 he1 HE1 No 0.36 0.36 0.45 85 1.01% 12.8 12.8 11.2 298 0.50% 1.41 3.5 N/A N/A N/A 16 16 15 hs1 HS1 No 0.15 0.15 0.19 24 45.92% 2.4 2.4 2.3 299 100.50% 20.05 0.2 N/A N/A N/A 5 5 5 N/A HW1 (Impervious) No 0.95 0.95 1.00 35 5.00% 1.0 1.0 0.6 425 0.90% 1.90 3.7 N/A N/A N/A 5 5 5 N/A HW1 (Pervious) No 0.15 0.15 0.19 35 5.00% 6.1 6.1 5.9 425 0.90% 1.90 3.7 N/A N/A N/A 10 10 10 N/A HE1 (Impervious) No 0.95 0.95 1.00 85 1.01% 2.6 2.6 1.7 298 0.50% 1.41 3.5 N/A N/A N/A 6 6 5 N/A HE1 (Pervious) No 0.15 0.15 0.19 85 1.18% 15.5 15.5 14.9 298 0.50% 1.41 3.5 N/A N/A N/A 19 19 18 N/A HS1 (Impervious) No 0.00 0.00 0.00 24 45.92% 2.8 2.8 2.8 N/A N/A N/A N/A N/A N/A 5 5 5 N/A HS1 (Pervious) No 0.15 0.15 0.19 24 45.92% 2.4 2.4 2.3 N/A N/A N/A N/A N/A N/A 5 5 5 HISTORIC TIME OF CONCENTRATION COMPUTATIONS C. Snowdon September 6, 2017 Design Point Basin Overland Flow Gutter Flow Swale Flow Time of Concentration (Equation RO-4) ( ) 3 1 1 . 87 1 . 1 * S C Cf L Ti = − Page 2 of 23 D:\Projects\1285-001\Drainage\Hydrology\1285-001_Rational-Calcs.xlsx\Hist-Tc-10-yr_&_100-yr HS1 (Pervious) 11546 0.27 0.00 0.00 0.00 0.00 0.27 0.15 0.15 0.19 0% HISTORIC COMPOSITE % IMPERVIOUSNESS AND RUNOFF COEFFICIENT CALCULATIONS Notes September 6, 2017 10-year Cf = 1.00 **Soil Classification of site is Sandy Loam** Runoff Coefficients are taken from the City of Fort Collins Storm Drainage Design Criteria and Construction Standards, Table 3-3. % Impervious taken from UDFCD USDCM, Volume I. Existing Impervious Area Breakdown Page 1 of 23 D:\Projects\1285-001\Drainage\Hydrology\1285-001_Rational-Calcs.xlsx\Hist-C-Values