Loading...
HomeMy WebLinkAboutFORT COLLINS JEEP - PDP - PDP170013 - SUBMITTAL DOCUMENTS - ROUND 3 - SITE PLANCG UE RL UE HC VICINITY MAP NO SCALE TITLE CERTIFICATION I, ____________________ AN AUTHORIZED REPRESENTATIVE OF _______________________ A TITLE INSURANCE COMPANY LICENSED TO DO BUSINESS IN THE STATE OF COLORADO, HAVE MADE AN EXAMINATION OF THE PUBLIC RECORDS AND STATE THAT ALL OWNERS, MORTGAGEES AND LIEN HOLDERS OF THE PROPERTY ARE LISTED IN THE CERTIFICATE OF OWNERSHIP AND LIENHOLDER SUBORDINATION CERTIFICATE. ______________________________________ AUTHORIZED REPRESENTATIVE AND TITLE ______________________________________ TITLE INSURANCE COMPANY SIGNED THIS _______ DAY OF ______________, 20___ SURVEYOR'S CERTIFICATE I, JOHN E. KRATZ, A REGISTERED PROFESSIONAL LAND SURVEYOR IN THE STATE OF COLORADO, DO HEREBY CERTIFY THAT THE SURVEY AND LEGAL DESCRIPTION REPRESENTED BY THE THIS SITE DEVELOPMENT PLAN WAS MADE UNDER MY SUPERVISION AND THIS SITE DEVELOPMENT PLAN ACCURATELY REPRESENTS THAT SURVEY. . . JOHN E. KRATZ P.L.S. 20142 DATE FOR AND ON BEHALF OF RED ROCK LAND SURVEYS LARIMER COUNTY CLERK AND RECORDER'S CERTIFICATE THIS SITE DEVELOPMENT PLAN WAS FILED FOR RECORD IN THE OFFICE OF THE COUNTY CLERK AND RECORDER OF LARIMER COUNTY AT ________, ON THE ________ DAY OF _________________, AD 20___. AT RECEPTION NO. ____________________ LARIMER COUNTY CLERK AND RECORDER BY: ____________________________ DEPUTY THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _____ DAY OF____________ AD, 20___ BY: _____________________________. WITNESS MY HAND AND OFFICIAL SEAL ____________________________________ NOTARY PUBLIC MY COMMISSION EXPIRES ___________________ OWNERSHIP CERTIFICATE THE UNDERSIGNED ARE ALL OF THE OWNERS OF CERTAIN LANDS DESCRIBED HEREON. BY:_____________________________________________________________________ NAME: TITLE: MORELAND PROPERTIES, LLC. A COLORADO LIMITED LIABILITY COMPANY SIGNED THIS ______ DAY OF ________________ AD, 20___ THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _____ DAY OF____________ AD, 20___ BY: ___________________________, AS _________________ OF MORELAND PROPERTIES, LLC. WITNESS MY HAND AND OFFICIAL SEAL ____________________________________ NOTARY PUBLIC MY COMMISSION EXPIRES ___________________ OWNER/DEVELOPER: COMMERCIAL BUILDING SERVICES 7561 S. GRANT STREET, SUITE A-4 LITTLETON, COLORADO 80122 PHONE: (303) 730-3001 CONTACT: STEVE MORE ENGINEER / PLAN PREPARER: PARAGON ENGINEERING CONSULTANTS, INC. GENERAL NOTES: 1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. [IF APPLICABLE -- INCLUDE LANGUAGE FOR ANY MODIFICATIONS AND CONDITIONS APPROVED WITH PDP/ODP]. 7. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 8. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 9. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 10. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED TO CONCRETE AND NOT INTERFERE WITH WALKWAYS OR LANDSCAPING. 11. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSIBLE PARKING SPACES. ACCESSIBLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 12. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS’ ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. AND, IF APPLICABLE: 13. THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT. 14. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 15. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 16. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. 17. NO VEHICLE DISPLAY ON DESIGNATED LANDSCAPE. 18. ALL CHAIN LINK FENCING TO BE VINYL-CLAD INCLUDING THE ROLLING GATES. FORT COLLINS JEEP PROJECT DEVELOPMENT PLAN GENERAL NOTES TWD 03/15/2017 N/A JLC 16-018 SS SS S S S S S S W W W W W W W W W W S S S S S S S S S W W W W W W W W W W W W W S S S S S X X X X X X X X X X X X X X X X X X X X S89°53'00"E 2649.99' (BASIS OF BEARINGS) POINT OF COMMENCEMENT SE COR. SEC. 35 T.7N, R.69W, 6TH P.M. FOUND 2-1/2" ALUM. CAP IN RANGE BOX PLS 17497 S. 1/4 COR. SEC. 35 T.7N, R.69W, 6TH P.M. FOUND 3-1/4" ALUM. CAP IN RANGE BOX, PLS 5028 MEDIAN CURB (ASPHALT) WEST HARMONY ROAD SOUTH MASON STREET (60' R.O.W.) (R.O.W. WIDTH VARIES) CONC. BIKE PARK GAS LINE MARKER "BIKE LANE" MEDIAN CURB (ASPHALT) SOUTH MASON STREET TEL. (ASPHALT) TRANSFORT BUS STOP (967.13') 23' 16' 7' 16' X X X X X X X X X X X X X X X X X X X X X X X ONLY ONLY 20.3' 20.1' 67.7' 23' 8.5' X X X X X X X X X X X X X X X X X X X X 5046 5046 5044 5044 5044 5042 5044 5046 5042 5040 5044 5048 5046 5046 5046 5042 S89°53'00"E 2649.99' (BASIS OF BEARINGS) (GRASS & TREES) METAL VEHICLE SHED W/ OVERHANG 126' X 31' (TO REMAIN) LOT 1 PEDERSEN AUTO PLAZA SUBDIVISION 2ND FILING (CONC. INTERSECTION) (R.O.W. WIDTH VARIES) SE COR. SEC. 35 T.7N, R.69W, 6TH P.M. FOUND 2-1/2" ALUM. CAP IN RANGE BOX PLS 17497 S. 1/4 COR. SEC. 35 T.7N, R.69W, 6TH P.M. FOUND 3-1/4" ALUM. CAP IN RANGE BOX PLS 5028 EX. "BIKE LANE" SIGN TO BE RELOCATE TRAFFIC LIGHT POLE BACK OF CURB BUS ROAD STORAGE SHED 8'X10' (TO REMAIN) EXCEPTED PARCEL EXCEPTED PARCEL 20100010805 20100015829 EXIST. WATER METER EXISTING TREES EXISTING SHRUBS EXISTING SHRUBS EX. LIGHT POLE TO BE RELOCATED EXIST. FENCE EXIST. FIRE HYDRANT "BUS STOP" TRANSFORMER (TO REMAIN) EXIST. FIRE HYDRANT (ASPHALT PARKING LOT) 27.0' 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 30,766 S.F. FINISHED FLOOR = 5045.9 ZONED - CG 7 7 4 5 5 WEST HARMONY ROAD VEHICLE DISPLAY CUSTOMER CUSTOMER CUSTOMER 6 EMPLOYEE EX. 1-STORY METAL BUILDING TO REMAIN EX. 1-STORY OPEN METAL GARAGE TO REMAIN AREA OF CONC. ENCROACHMENT CITY OF FORT COLLINS REC. NO. 20120033213 INLET GRATE EXISTING TREES 17' 36' 23' 36' 23' 23' 16' 28' 18' 36' 23' 16' 18' 25' 16' 16' 16' 23' 36' 16' 36' 22.1' 24' 9' 9' 9' 9' 9' 18' 18' 18' 9' 8.5' 9' 9' 9' 9' 8' 9' 9' 9' 12.8' 9' 9' 9' 9' 8' 9' 9' 9' 9' 9' 9.5' 10.2' 23.7' 20.4' 10.8' 2.9' 11.4' 8.7' 23' 29.5' 149.9' 83.2' 82.8' 88.1' 12' 12' 9' EX. 5' U.E. 2' 2' 15' U.E. 15' U.E. 8.5' BIKE LANE 12' TURN LANE 6.5' TREELAWN 8' SIDEWALK 20' EMERGENCY ACCESS ESMT. 12' DRIVE LANE 16' 20' EMERGENCY ACCESS ESMT. 25.3' 15' DRAINAGE ESMT. EXIST. 60' R.O.W. PROPOSED 72' R.O.W. 15' DRAINAGE ESMT. 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 15' DRAINAGE ESMT. 20' EMERGENCY ACCESS ESMT. 9' 100' (ASPHALT PARKING LOT) COMMS EXISTING 5' CONC. WALK 19' 17' BIKE RACK (4) 12 12 11 11 16 14 14 9 13 13 11 10 15 7 6 9 9 12 12 11 12 12 7 13 PROPOSED BUS STOP 5707 S.F. R.O.W. DEDICATED TO CITY PROPOSED COVERED CANOPY PROPOSED 6' VINYL-CLAD CHAIN-LINKED FENCE CONC. DRAINAGE CHANNEL CONC. DRAINAGE CHANNEL PROPOSED 6' VINYL-CLAD CHAIN-LINKED FENCE END PROPOSED 6' CHAIN-LINK FENCE ALONG WEST PROPERTY LINE PROPOSED ROLLING GATE 4"Ø X 30" H, PIPE BOLLARDS, FILL WITH CONC. CAP AND PAINT, TYP. INSTALL @ 6' 0.C. 4"Ø X 30" H, PIPE BOLLARDS, FILL WITH CONC. CAP AND PAINT, TYP. INSTALL @ 6' 0.C. EXIST. 6' CHAIN-LINKED FENCE ALONG PARKWAY PROPOSED ROLLING GATE JEEP HILL DISPLAY 8' WIDE CONC. PATH FROM SIDEWALK TO BLDG., LIGHT BOLLARDS ON BOTH SIDES OF AREAS WHERE PARKING IS ADJACENT VEHICLE STORAGE EMPLOYEE EMPLOYEE 15 TRASH ENCLOSURE METAL PANEL W/ GATES COLOR TO MATCH BLDG. 214 S.F. R.O.W. DEDICATED TO CITY PROPOSED TRANSIT ESMT. EXIST. FENCE W/ GATE PROPERTY LINE EXIST. CURB CUT EXIST. SIDEWALK CONC. DRAINAGE CHANNEL DRIVE AISLE (DIRT) (ASPHALT PARKING LOT) 12' DRIVE LANE 5' BIKE LANE BNSF RAIL-ROAD R.O.W. 5' PEDESTRIAN ACCESS ESMT. 5' 5' PEDESTRIAN ACCESS ESMT. 5' EX. 5' U.E. RELOCATED "BIKE LANE" SIGN 20' W.L. ESMT. KENSINGTON DRIVE (54' R.O.W.) GATEWAY AT HARMONY ROAD PUD 2ND FILING GATEWAY AT HARMONY ROAD PUD 3ND FILING GATEWAY AT HARMONY ROAD PUD 3ND FILING 6.9' 54' 54' 15' LANDSCAPE WALL LANDSCAPE WALL X EX. 1-STORY OPEN METAL GARAGE PROPERTY LINE 100' BNSF RAIL-ROAD R.O.W. Feet 0 30 60 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION PROPERTY LINE LOT / TRACT LINE LEGEND: S S W W EXISTING SANITARY LINE W/ MH EXISTING STORM LINE W/ MH EXISTING WATER LINE EXISTING STORM AREA INLET EXISTING FIRE HYDRANT EXISTING WATER VALVE D Y H EXISTING STORM TYPE 'R' INLET RIGHT-OF-WAY E E EXISTING ELECTRIC LINE G G EXISTING GAS LINE X X EXISTING FENCE LINE 5530 PROPOSED CONTOUR 5530 EXISTING CONTOUR S S PROPOSED SANITARY SEWER W/ MH PROPOSED STREET SIGN PROPOSED STORM SEWER W/ MH W W PROPOSED WATER LINE PROPOSED FIRE HYDRANT CTV EXISTING CATV LINE CENTERLINE R.O.W. EXISTING CONCRETE PROPOSED EASEMENT LINE EXISTING EASEMENT LINE PROPOSED WATER VALVE PROPOSED WATER FITTINGS 4 5 PROPOSED TYPE 'R' INLET PROPOSED FLARED END SECTION EXISTING RIGHT-OF-WAY PROPOSED STREET LIGHT D S COM COM EXISTING COMMUNICATION LINE PROPOSED LANDSCAPE PROPOSED ASPHALT PROPOSED CONCRETE FORT COLLINS JEEP PROJECT DEVELOPMENT PLAN SITE PLAN TWD 03/15/2017 1" = 30' JLC 16-018 4 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 09/07/2017 C SUBMITTED TO FTC 09/08/2017 SIDEWALK REPAIR NOTE: ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. MATCHLINE - LOWER RIGHT MATCHLINE - UPPER LEFT STREET CUT NOTE: LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. "PUSH TO WALK" (TO BE RELOCATED) BACKFLOW PREVENTER AND VALVE CONTROL BOX COBBLESTONE LANDSCAPE (TYPICAL, TO BE REMOVED AND STOCK PILED FOR LATER USE) COVERED BUS STOP (TO BE STORED AND RELOCATED) COMMS TEL. EX. TRAFFIC LIGHT POLE MAILBOX INLET GRATE (REMOVE) (ASPHALT PARKING LOT) GATE (REMOVE) (GATE) 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 25,430 S.F. FINISHED FLOOR = 5045.9 TRANSFORMER TO REMAIN (PROTECT DURING CONSTRUCTION) 100.3 27.0 20.4 116.7 19.8 44.0 36.0 26.0 65.0 80.0 20.0 20.0 20.5 20.5 39.1 40.5 27.0 15.0 12.5 8.7 (GATE) (GRASS & TREES) (RAISED CONC. DOCK) (DIRT) METAL VEHICLE SHED 126' X 31' W/ OVERHANG TO REMAIN (ASPHALT PARKING LOT) (ASPHALT PARKING LOT) LOT 1 PEDERSEN AUTO PLAZA SUBDIVISION 2ND FILING (CONC. INTERSECTION) (ASPHALT) TRANSFORT BUS STOP BACK OF CURB BUS ROAD (967.13') EX. CHAIN-LINK FENCE TO REMAIN ALONG PROPERTY LINE 8'X10' STORAGE SHED TO REMAIN 20.3' 20.1' 67.7' 80.9' 78.3' 108.7' EXCEPTED PARCEL 20100010805 EXCEPTED PARCEL 20100015829 5040 5042 5044 5042 5042 5042 5046 5044 5044 5050 5046 5048 5046 5042 5044 5040 5044 5042 5044 5046 5046 5046 5046 5048 5046 5046 10" AC EX. SEWER SERVICE EX. FIRE HYDRANT (TO BE RELOCATED) 8" WATER 8" SANITARY "PED X-ING" (GRASS & TREES) (GRASS & TREES) "BUS STOP" RELOCATE EX. CONCRETE TO BE REMOVED EX. CONCRETE TO BE REMOVED EX. CONCRETE PAD TO BE REMOVED EX. SEWER SERVICE TO BE ABANDONED AND DISCONECTED AT MANHOLE EX. TREES TO BE REMOVED EX. TREES TO BE REMOVED AND REPLACED REMOVE AND REPLACE EXISTING ASPHALT REMOVE AND REPLACE EXISTING ASPHALT REMOVE AND REPLACE EXISTING ASPHALT REMOVE AND REPLACE EXISTING ASPHALT EX. CONCRETE TO BE REMOVED EX. CONCRETE TO BE REMOVED EX. TREES AND SHRUBS TO BE REMOVED AND REPLACED EX. TREES AND SHRUBS TO BE REMOVED EX. TREE TO BE REMOVED AND REPLACED EX. TREES TO BE REMOVED AND REPLACED EX. CONCRETE TO BE REMOVED EX. FENCE TO BE REMOVED EX. SIGN (REMOVE) EX. STREET LIGHT TO BE RELOCATED EX. FENCE TO BE REMOVED EX. FENCE AND GATE TO BE REMOVED EX. WATER METER (TO BE REMOVED) STORM INLET (TO BE REPLACED) DEMO EX. CURB, GUTTER AND SIDEWALK DEMO EX. DRIVECUT AND SIDEWALK DEMO EX. CURB, GUTTER AND SIDEWALK DEMO EX. CONCRETE PAD AT BUS STOP EX. FENCE TO BE REMOVED EX. FENCE TO BE REMOVED REMOVE EX. CURB, GUTTER, SIDEWALK AND TREES AT NEW BUS STOP TURN OUT 5' UTILITY EASEMENT PROPERTY LINE PROPERTY LINE CITY OF FORT COLLINS REC. NO. 20120033213 EXIST. BLDG TO REMAIN EX. CURB CUT ±33' PROPERTY LINE 100' BNSF RAIL-ROAD R.O.W. GATEWAY AT HARMONY ROAD PUD 2ND FILING GATEWAY AT HARMONY ROAD PUD 3ND FILING GATEWAY AT HARMONY ROAD PUD 3ND FILING X EXIST. BLDG TO REMAIN PROPERTY LINE 100' BNSF RAIL-ROAD R.O.W. Feet 0 30 60 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION PROPERTY LINE LOT / TRACT LINE LEGEND: S S W W EXISTING SANITARY LINE W/ MH EXISTING STORM LINE W/ MH EXISTING WATER LINE EXISTING STORM AREA INLET EXISTING FIRE HYDRANT EXISTING WATER VALVE D Y H EXISTING STORM TYPE 'R' INLET RIGHT-OF-WAY E E EXISTING ELECTRIC LINE G G EXISTING GAS LINE X X EXISTING FENCE LINE 5530 EXISTING CONTOUR CTV EXISTING CATV LINE CENTERLINE R.O.W. EXISTING CONCRETE EXISTING EASEMENT LINE EXISTING RIGHT-OF-WAY D COM COM EXISTING COMMUNICATION LINE EXISTING TREE/SHRUB EXISTING LIGHT SS EXISTING FENCE EXISTING ELEC. BOX EXISTING IRRIGATION FORT COLLINS JEEP PROJECT DEVELOPMENT PLAN EXISTING CONDITIONS PLAN TWD 03/15/2017 1" = 30' JLC 16-018 3 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 MATCHLINE - LOWER RIGHT MATCHLINE - UPPER LEFT STREET CUT NOTE: LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEER INSPECTOR. ALL REPAIRS SHALL BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS 2 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION 7852 S. ELATI STREET, SUITE 106 LITTLETON, COLORADO 80120 PHONE: (303) 794-8604 FAX: (303) 795-3072 CONTACT: TROY DENNING, P.E. CONTACTS: CIVIL ENGINEER'S STATEMENT I, TROY W. DENNING, BEING A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF COLORADO, HEREBY ATTEST THAT ALL GRADING, UTILITY AND DRAINAGE IMPROVEMENTS IDENTIFIED ON THIS SITE DEVELOPMENT PLAN HAVE BEEN DESIGNATED AND ENGINEERED IN CONFORMANCE WITH ALL CITY OF FORT COLLINS PUBLIC WORKS CONSTRUCTION STANDARDS. . . TROY W. DENNING P.E. 34200 DATE PARAGON ENGINEERING CONSULTANTS, INC. PLANNING COMMISSION RECOMMENDATION THIS SITE DEVELOPMENT PLAN DEPICTED HEREON WAS RECOMMENDED FOR APPROVAL BY THE PLANNING COMMISSION OF THE CITY OF FORT COLLINS, COLORADO ON THE _____ DAY OF __________. 20_____. __________ _________________ ______________________________________ CHAIR DATE ATTEST: __________ ____________________________ _______________________________________ DIRECTOR OF DEVELOPMENT SERVICES DATE PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 FORT COLLINS JEEP - PROJECT DEVELOPMENT PLAN LOCATED IN THE SOUTHEAST ONE-QUARTER OF SECTION 35, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Reviewed by:____________________________________________________________ LARIMER COUNTY ENGINEERING DATE LANDSCAPE PLANNER: CENTENNIAL, CO. 80120 PHONE: (303) 741-3467 CONTACT: PEGGY GOLDEN, RLA,ASLA #261 TOWN COUNCIL APPROVAL THIS SITE DEVELOPMENT PLAN WAS APPROVED BY THE TOWN COUNCIL OF THE CITY OF FORT COLLINS, COLORADO, ON THE ______ DAY OF _______________________, 20______. __________ __________________________ _____________________________ MAYOR DATE ATTEST: __________ __________________________ _____________________________ TOWN CLERK DATE LAND SURVEYOR: RED ROCK LAND SURVEYS 7865 W. ONTARIO PLACE LITTLETON, COLORADO 80128 PHONE: (303) 994-6300 CONTACT: JOHN E. KRATZ, PLS GOLDEN ENTERPRISES CONSULTING 7442 S. BIRCH ST. SITE I _______________________________ CERTIFY ALL PUBLIC WATER AND WASTEWATER SYSTEM IMPROVEMENTS SHOWN HEREIN, INCLUDING ANY NOTED CHANGES OR REVISIONS, ARE IN GENERAL CONFORMANCE WITH THE DESIGN/CONSTRUCTION DOCUMENTS, PURSUANT TO THIS RECORD DRAWING COPY OF THE FINAL PICPS. 2.3.4 SUBMITTAL SUMMARY TABLE: QUANTITIES USE AREAS S.F. ACREAGE PERCENTAGE BUILDING AREA 34,752 0.8 18.3 LANDSCAPE AREA 30,390 0.70 16.0 NEW PAVEMENT AREA 111,854 2.57 59.2 CONCRETE 12,389 0.28 6.5 TOTAL 189,385 4.35 100.00 VEHICLE STORAGE PARKING 272 STALLS EMPLOYEE PARKING 35 STALLS CUSTOMER PARKING 18 STALLS HANDICAP PARKING 3 STALLS BIKE 4 STALLS FORT COLLINS JEEP PROJECT DEVELOPMENT PLAN COVER SHEET TWD 03/15/2017 N/A JLC 16-018 1 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION 5 LANDSCAPE PLAN 6 7 PHOTOMETRIC PLAN BUILDING ELEVATIONS LEGAL DESCRIPTION: KNOW ALL MEN BY THESE PRESENTS, THAT THE UNDERSIGNED, BEING OWNERS OF THE FOLLOWING DESCRIBED LAND: A PARCEL OF LAND LOCATED IN THE SOUTHEAST ONE-QUARTER OF SECTION 35, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHEAST CORNER OF SAID SOUTHEAST ONE-QUARTER AND CONSIDERING THE SOUTH LINE OF SAID SOUTHEAST ONE-QUARTER TO BEAR N89°53'00”W; THENCE N89°53'00”W, ALONG SAID SOUTH LINE, A DISTANCE OF 967.13 FEET; THENCE N1°05'37”E A DISTANCE OF 50.00 FEET TO THE POINT OF BEGINNING ON THE NORTHERLY RIGHT-OF-WAY LINE OF WEST HARMONY ROAD; THENCE ALONG THE EASTERLY LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20120033213 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER, THE FOLLOWING SEVEN (7) COURSES: 1. N1°05'37”E A DISTANCE OF 224.10 FEET; 2. N89°58'15”W A DISTANCE OF 5.00 FEET; 3. N1°05'37”E A DISTANCE OF 81.29 FEET; 4. N88°54'23”W A DISTANCE OF 5.00 FEET TO A POINT OF NON-TANGENT CURVE; 5. NORTHWESTERLY, ALONG THE ARC OF SAID CURVE TO THE LEFT, HAVING A CENTRAL ANGLE OF 28°33'29”, A RADIUS OF 150.50 FEET, AN ARC LENGTH OF 75.01 FEET AND A CHORD BEARING AND DISTANCE OF N12°44'40”W, 74.24 FEET TO A POINT OF REVERSE CURVE; 6. NORTHWESTERLY, ALONG THE ARC OF SAID CURVE TO THE RIGHT, HAVING A CENTRAL ANGLE OF 20°00'08”, A RADIUS OF 99.50 FEET, AN ARC LENGTH OF 34.74 FEET AND A CHORD BEARING AND DISTANCE OF N17°01'11”W, 34.56 FEET; 7. N1°05'37”E A DISTANCE OF 70.00 FEET TO THE SOUTH LINE OF LOT 1, PEDERSON AUTO PLAZA SUBDIVISION; THENCE S89°48'40”E, ALONG SAID SOUTH LINE, A DISTANCE OF 435.54 FEET TO THE WESTERLY RIGHT-OF-WAY LINE OF SOUTH MASON STREET; THENCE S1°03'05”W, ALONG SAID WESTERLY LINE, A DISTANCE OF 462.10 FEET TO THE NORTHWESTERLY LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20100010805 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER; THENCE S43°16'52”W, ALONG SAID NORTHWESTERLY LINE, A DISTANCE OF 20.21 FEET TO THE NORTH LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20100015829 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER AND SAID NORTHERLY RIGHT-OF-WAY LINE OF WEST HARMONY ROAD; THENCE ALONG SAID LINE THE FOLLOWING THREE (3) COURSES: 1. N89°53'01”W A DISTANCE OF 280.33 FEET; 2. S73°53'58”W A DISTANCE OF 12.50 FEET; 3. N89°53'00”W A DISTANCE OF 91.54 FEET TO THE POINT OF BEGINNING. WHICH ABOVE DESCRIBED TRACT CONTAINS 195,092 SQUARE FEET OR 4.479 ACRES OF LAND, MORE OR LESS. THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). FOR THEMSELVES AND THEIR SUCCESSORS IN INTEREST (COLLECTIVELY, "OWNER") HAVE CAUSED THE ABOVE DESCRIBED LAND TO BE SURVEYED AND SUBDIVIDED IN TO A LOT AS SHOWN ON THIS PLAT TO BE KNOWN AS FORT COLLINS JEEP FINAL PLAT (THE "DEVELOPMENT"), SUBJECT TO ALL EASEMENTS AND RIGHTS-OF-WAY NOW OF RECORD OR EXISTING OR INDICATED ON THIS PLAT. THE RIGHTS AND OBLIGATIONS OF THE PLAT SHALL RUN WITH THE LAND. SHEET INDEX Sheet Number Sheet Title 1 COVER SHEET 2 GENERAL NOTES 3 EXISTING CONDITIONS PLAN 4 SITE PLAN 8 TREE INVENTORY PLAN