Loading...
HomeMy WebLinkAboutTHE UNION ON ELIZABETH (FORMERLY 1208 W. ELIZABETH STREET) - PDP/FDP - FDP170024 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSNo. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 17 AUGUST 2017 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: VICINITY MAP NORTH 1"=1500' PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 20-97 At the Southwest corner of West Elizabeth and Constitution Ave. on a concrete traffic signal base. ELEV.= 5050.15 City of Fort Collins Benchmark 19-97 At the Southeast corner of West Elizabeth and Shields St., on a concrete traffic signal base. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary X TF W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR VAULT VAULT ELEC ELEC VAULT TELE VAULT ELEC WV VAULT ELEC VAULT ELEC S WV WV H Y D VAULT F.O. FO T MH MH ELEC C.O. G G C.O. T G E ELEC BRKR ELEC BRKR EE E T ELEC BRKR E EE ELEC BRKR G C.O. G T CABLE ELEC G T ELEC CTV CTV T VAULT F.O. FO CABLE X X X X X X X X X X X X X X X X X X X X TF X LS 23524 FDC MATCH EXISTING FLOWLINE TIE PAN TO EXISTING FLOWLINE PROPOSED 2' CONCRETE PAN PROPOSED SAWCUT EXISTING SIDEWALK CHASE EXISTING SIGN (TYP.) WEST ELIZABETH STREET (80' ROW) PROPOSED SAWCUT PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 6' CONCRETE PAN PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 4' CONCRETE PAN N:126817.51 E:189133.38 N:126824.52 E:188773.78 N:126545.83 E:188770.94 N:126540.47 E:189130.90 MATCH EXISTING MATCH EXISTING FLOWLINE X TF X W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR UD UD UD UD UD UD UD UD UD UD UD UD TF W CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E TF W UD UD UD UD UD S W W F S S S VAULT ELEC VAULT TELE VAULT ELEC VAULT ELEC VAULT ELEC S WV H Y D VAULT F.O. FO T T CABLE CTV T E X X X X X E E E E E E E SS SS SS SS SS SS SS SS X X VAULT F.O. FO CABLE CTV T X X X X X X X X X X X X X X X X X X X FDC UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD X TF X LOT 3, CAMPUS WEST SHOPPING CENTER COLLINS CAMPUS WEST LLC 1110 W ELIZABETH ST LOT 1, CAMPUS WEST SHOPPING CENTER NCIC LLC 1232 W ELIZABETH ST TOWN SQUARE CONDOMINIUMS LOKAL FORT COLLINS CO LLC 1201 W PLUM ST CAMBRIDGE HOUSE LOFTS BRIDGE-CAMBRIDGE LP 1113 W PLUM ST LOT 1, SOUTH SHIELDS SUBDIVISION 825 S SHIELDS LLC 825 S SHIELDS ST 20' - 24' - (30.13) (30.00) (29.21) (29.09) (28.22) (28.05) (27.94) (27.03) (27.22) (28.91) (28.72) (31.00) (29.27) (29.10) (27.13) LS 23524 FDC PROPOSED 18" VERTICAL PROPOSED 8" HDPE INFLOW CURB & GUTTER STORM DRAIN (SEE SHEET C300) VAULT AREA PROPOSED OUTLET STRUCTURE (SEE DETAIL SHEET C502) 31.34 31.29 31.33 31.38 31.09 30.79 30.67 30.67 30.67 30.67 31.03 31.12 36.62 36.53 37.06 31.33 31.33 37.06 36.53 36.47 36.45 36.54 31.04 31.13 31.09 31.03 31.30 31.40 31.24 31.30 31.33 31.43 31.95 31.86 31.86 32.83 33.00 29.40 33.00 29.21 29.34 29.35 29.30 29.40 29.62 32.82 33.00 33.00 32.67 PROPOSED 2' SIDEWALK CHASE MATCH EXISTING CURB & GUTTER PROPOSED 31" DRIVE-OVER CURB & GUTTER MATCH EXISTING FLOWLINE MATCH EXISTING FLOWLINE DETENTION AREA TIE TO EXISTING WALK EXISTING VERTICAL CURB & GUTTER TIE TO EXISTING WALK (29.21) (29.09) (28.22) (28.05) (27.94) (28.91) (28.72) WEST ELIZABETH STREET (80' ROW) PROPOSED 8" HDPE STORM DRAIN (SEE SHEET C300) PROPOSED DETENTION OUTLET w/ ORIFICE PLATE (SEE DETAIL SHEET C502) TW=5029.20 TW=5029.20 (3) - 6.5" RISERS w/ 12" TREADS PROPOSED TRENCH DRAIN (SEE DETAILS) N:126545.83 E:188770.94 PROPOSED 18" CONCRETE WALL MATCH EXISTING FLOWLINE MATCH EXISTING FLOWLINE FFE=31.33 PROPOSED BIO-SWALE 28.35 28.68 29.20 (29.31) 29.11 28.44 28.48 29.09 29.20 UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD BASIN A5 (SOLID LID) INV.=5028.99 FG=5031.22 BASIN A4 (SOLID LID) INV.=5028.44 FG=5030.78 BASIN A3 (SOLID LID) INV.=5028.38 FG=5030.73 138.16 LF 8" PERF. HDPE @ 0.40% 14.10 LF 8" PERF. HDPE @ 0.40% 28.43 SUB 28.43 SUB 29.04 SUB 29.04 SUB 31.24 31.22 30.94 30.93 0.4% 0.5% 0.5% 0.4% 0.4% PROPOSED CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C500 UTILITY DETAILS A. Reese B. Ruch NTS No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C501 UTILITY DETAILS A. Reese B. Ruch NTS No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 12 of 17 City Engineer Date No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 13 of 17 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C503 SITE DETAILS A. Reese B. Ruch N/A NOT TO SCALE 400 C503 CURB AND GUTTER UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD X TF VAULT F.O. FO CABLE T X X X X X X X X X X X X X X X X X X X LS 23524 FDC VTC CWA CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF RS RS RS RS RS RS RS RS RS RS CF CF CF CF CF CF CF CF CF WD WD WD WD WD WD WD WD WD WD WD PROPOSED 2' CONCRETE PAN PROPOSED 2' SIDEWALK CHASE PROPOSED STORM DRAIN PROPOSED 2' SIDEWALK CHASE EXISTING 2' No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 15 of 17 C601 EROSION CONTROL DETAILS A. Reese B. Ruch 1"=20' VEHICLE TRACKING CONTROL PAD SHALL BE LOCATED AT EVERY ACCESS POINT TO THE CONSTRUCTION SITE. A SIGN SHALL BE PLACED NEXT TO THE VEHICLE TRACKING CONTROL PAD TO DESIGNATE THE LOCATION AS THE CONSTRUCTION ENTRANCE/EXIT. VEHICLE TRACKING CONTROL PADS SHALL CONSIST OF HARD, DENSE, DURABLE STONE, ANGULAR IN SHAPE AND RESISTANT TO WEATHERING. ROUNDED STONE (i.e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t t t X X X X T T T T T T T T T T X TF X UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD 1 1 0.30 2 0.51 3 1.04 4 0.35 2 3 4 5 0.02 5 PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE EXISTING 2' SIDEWALK CHASE PROPOSED 8" HDPE UNDERDRAIN PROPOSED TRENCH DRAIN PROPOSED X TF X W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR VAULT F.O. FO T T CABLE CTV T E E E E E E E E t t t T T T T T T T T T T UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD LS 23524 FDC 5028 (NAVD88) 5027 (NAVD88) 5029 (NAVD88) 5028.12 (NAVD88) 5028.60 (NAVD88) 5029.12 (NAVD88) 5029.85 (NAVD88) 493 584 804 677 324 5026.99 (NAVD88) FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 LOT 3, CAMPUS WEST SHOPPING CENTER COLLINS CAMPUS WEST LLC 1110 W ELIZABETH ST LOT 1, CAMPUS WEST SHOPPING CENTER NCIC LLC 1232 W ELIZABETH ST TOWN SQUARE CONDOMINIUMS LOKAL FORT COLLINS CO LLC 1201 W PLUM ST CAMBRIDGE HOUSE LOFTS BRIDGE-CAMBRIDGE LP 1113 W PLUM ST LOT 1, SOUTH SHIELDS SUBDIVISION 825 S SHIELDS LLC 825 S SHIELDS ST WEST ELIZABETH STREET (80' ROW) INTERPOLATED CSL 5029.60 (NAVD88) FFE=30.09 FFE =30.36 FFE =31.18 NORTHERN ENGINEERING PROJECT NO. 1252-006 DATE: APRIL 2017 PLS GROUP PROJECT NO. 16066.002 DATE: MAY 2017 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C800 FLOODPLAIN EXHIBIT A. Reese B. Ruch 1"=20' FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 17 of 17 LEGEND: PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER ST PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPOSED STORM INLET PROPOSED CONCRETE CROSS PAN (TYP.) PEDESTRIAN ACCESS RAMPS PROPERTY BOUNDARY CROSS-SECTION (CSL) XS#: 2446 NOTES: 1. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION 2. THIS PROJECT IS LOCATED WITHIN A CITY-REGULATED OLD TOWN 100-YEAR FLOODWAY AND FLOOD FRINGE AND MUST COMPLY WITH CHAPTER 10 OF THE CITY CODE. 3. ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE PER THE CITY OF FORT COLLINS VERTICAL CONTROL DATUM (NAVD 88). 4. ANY ITEMS LOCATED IN THE FLOODWAY THAT CAN FLOAT (E.G., PICNIC TABLES, BIKE RACKS, ETC.) MUST BE ANCHORED. 5. A FLOODPLAIN USE PERMIT SHALL BE REQUIRED FOR EACH SITE CONSTRUCTION ELEMENT IN THE FLOODPLAIN. 6. NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY. 7. REFER TO THE FINAL DRAINAGE REPORT FOR UNION ON ELIZABETH, DATED AUGUST 16, 2017 FOR ADDITIONAL INFORMATION. 8. A FLOODPLAIN USE PERMIT AND NO RISE CERTIFICATION IS REQUIRED PRIOR TO PERFORMING ANY WORK WITHIN THE FLOODWAY (I.E., CURB CUT REMOVAL, LANDSCAPING). 9. ALL HVAC EQUIPMENT IS TO BE LOCATED ON THE ROOFTOP OF THE STRUCTURE. 10. HORIZONTAL CONTROL: CITY OF FORT COLLINS GROUND MASTER CONTROL. FIELD SURVEY BY: BENCHMARKS: 5013 PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 20-97 AT THE SOUTHWEST CORNER OF WEST ELIZABETH AND CONSTITUTION AVE. ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.=5050.15 CITY OF FORT COLLINS BENCHMARK 19-97 AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.=5025.74 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.18' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE NORTH LINE OF LOT 4 AS BEARING SOUTH 88°52'58" EAST. LOWEST FLOOR ELEVATION = C BASE FLOOD ELEVATION (BFE) = A MINIMUM HVAC EQUIPMENT ELEVATION = B BASE FLOOD ELEVATION (BFE) = A 18" MIN. HVAC UNIT DETAIL NTS SLAB-ON-GRADE MIXED-USE BUILDING SUMMARY ELEV. DESIGNATION PROJECT ELEV. (NAVD 88) A 5029.60 FT B 5031.10 FT C 5031.10 FT REGULATORY FLOOD PROTECTION ELEVATION 5029.60 FT BASE FLOOD ELEVATION (BFE) ELEVATION NGVD 88 5000 EXISTING 100-YEAR CITY FLOODWAY EXISTING 100-YEAR CITY FLOODPLAIN OUTLET STRUCTURE VAULT AREA PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 2' CURB CUT PROPOSED 6' CONCRETE PAN PROPOSED 2' CURB CUT APPROXIMATE LOCATION EXISTING 24" RCP STORM DRAIN LOT 3, CAMPUS WEST SHOPPING CENTER COLLINS CAMPUS WEST LLC 1110 W ELIZABETH ST LOT 1, CAMPUS WEST SHOPPING CENTER NCIC LLC 1232 W ELIZABETH ST TOWN SQUARE CONDOMINIUMS LOKAL FORT COLLINS CO LLC 1201 W PLUM ST CAMBRIDGE HOUSE LOFTS BRIDGE-CAMBRIDGE LP 1113 W PLUM ST LOT 1, SOUTH SHIELDS SUBDIVISION 825 S SHIELDS LLC 825 S SHIELDS ST WEST ELIZABETH STREET (80' ROW) OS1 3.10 OS1 OS2 0.22 OS2 SEE DRAINAGE REPORT FOR HISTORIC DRAINAGE EXHIBIT SHOWING OFFSITE BASIN DELINEATION SEE DRAINAGE REPORT FOR HISTORIC DRAINAGE EXHIBIT SHOWING OFFSITE BASIN DELINEATION SAND FILTER AREA DETENTION AREA PROPOSED 12" RCP CULVTER PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED ROOF DRAIN CONNECTION PROPOSED ROOF DRAIN CONNECTION PROPOSED RAIN GARDEN PROPOSED BIO-SWALE PROPOSED 4' CONCRETE PAN PROPOSED TRENCH DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C700 DRAINAGE EXHIBIT A. Reese B. Ruch 1"=20' NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 16 of 17 LEGEND: 4953 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET DESIGN POINT A FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 1 1 NOTES: 1. REFER TO THE FINAL DRAINAGE REPORT FOR UNION ON ELIZABETH, DATED AUGUST 16, 2017 FOR ADDITIONAL INFORMATION. BASIN DESIGNATION AREA BASIN (AC) BENCHMARK FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION C 0.60 ac PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 20-97 AT THE SOUTHWEST CORNER OF WEST ELIZABETH AND CONSTITUTION AVE. ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.=5050.15 CITY OF FORT COLLINS BENCHMARK 19-97 AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.=5025.74 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.18' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE NORTH LINE OF LOT 4 AS BEARING SOUTH 88°52'58" EAST. DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) 1 1 0.30 0.33 0.41 8.4 7.9 0.2 1.1 2 2 0.51 0.71 0.89 9.3 8.8 0.8 3.7 3 3 1.04 0.95 1.19 5.0 5.0 2.8 12.3 4 4 0.35 0.51 0.64 9.2 8.7 0.4 1.8 5 5 0.017 0.25 0.31 5.0 5.0 0.012 0.054 CONSTRUCTION FENCE, TYP., TO DISCOURAGE VEHICLE ACCESS EXCEPT AT VTC SIGN "CONSTRUCTION ENTRANCE" \A1;R=5' PAVED SURFACE \A1;20' MIN. A SECTION A NO MATERIALS INCLUDING 2x4'S, PIPES, DIRT, GRAVEL OR ASPHALT, SHALL BE PLACED IN GUTTER TO FACILITATE MOUNTING CURB; HOWEVER, CURB MAY BE CUT DOWN TO A HEIGHT OF 2" OR HIGHER FOR EASIER ACCESS AND REPLACED AT PROJECT COMPLETION. OTHER ACCESS DEVICES MAY BE USED AS ACCEPTED BY THE CITY. 3" - 6" ROCK CURB CUT 50' MIN. 2" MIN. 6" MIN. 6" MIN. ALTHOUGH NOT NORMALLY USED, THE CITY RESERVES THE RIGHT TO REQUIRE VEHICLE TRACKING CONTROL WITH A TEMPORARY CATTLE GUARD AND/OR WHEEL WASH FACILITIES AT SITES WHERE TRACKING ONTO PAVED AREAS BECOMES A SIGNIFICANT PROBLEM AS DETERMINED BY THE CITY INSPECTOR. IF VEHICLE TRACKING CONTROL WITH WHEEL WASH FACILITIES ARE REQUIRED, ALL WHEELS ON EVERY VEHICLE LEAVING THE SITE SHALL BE CLEANED OF MUD USING A PRESSURE-WASHER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A WATER SOURCE AND CONSTRUCTING A WASHWATER SEDIMENT TRAP. 5. 6. IF VEHICLE WHEEL WASH FACILITIES ARE REQUIRED, CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL AND WHEEL WASH FACILITIES DAILY. ACCUMULATED SEDIMENTS SHALL BE REMOVED FROM THE PAD SURFACE. ACCUMULATED SEDIMENT IN THE WASHWATER/SEDIMENT TRAP SHALL BE REMOVED WHEN THE SEDIMENT REACHES AN AVERAGE DEPTH OF 12-INCHES. 4. 5. VTC 0" ON BEDROCK OR HARD SURFACE, 2" IN SOIL ROCK SOCK SECTION ROCK SOCK PLAN 4" TO 6" MAX AT CURBS, OTHERWISE 6"-10" DEPENDING ON EXPECTED SEDIMENT LOADS ROCK SOCK JOINTING \A1;12" \A1;12" {ROCK SOCK INSTALLATION NOTES }1.SEE PLAN VIEW FOR: - LOCATION (S) OF ROCK SOCKS. 2.CRUSHED ROCK SHALL BE 1{}" (MINUS) IN SIZE WITH A FRACTURED FACE (ALL SIDES) AND SHALL COMPLY WITH GRADATION SHOWN ON THIS SHEET (1{}" MINUS). 3.WIRE MESH SHALL BE FABRICATED OF 10 GAGE POULTRY MESH, OR EQUIVALENT, WITH A MAXIMUM OPENING OF {}", RECOMMENDED MINIMUM ROLL WIDTH OF 48". 4.WIRE MESH SHALL BE SECURED USING "HOG RINGS" OR WIRE TIES AT 6" CENTERS ALONG ALL JOINTS AND AT 2" CENTERS ON ENDS OF SOCKS. 5.SOME MUNICIPALITIES MAY ALLOW THE USE OF FILTER FABRIC AS AN ALTERNATIVE TO WIRE MESH FOR THE ROCK ENCLOSURE. GRADATION TABLE SIEVE SIZE MASS PERCENT PASSING SQUARE MESH SIEVES NO. 4 2" 100 1-1/2" 90-100 1" 20-55 3/4" 0-15 3/8" 0-5 MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE, ALL SIDES WIRE ENCLOSED 1 1/2" WASHED ROCK CURB AND GUTTER TUBULAR MARKER \A1;2' RS NOT TO SCALE 001 C601 CONCRETE WASHOUT AREA NOT TO SCALE 002 C601 ROCK SOCK NOT TO SCALE 003 C601 VEHICLE TRACKING BAG NOT TO SCALE 004 C601 CONSTRUCTION FENCE w/ ROCK SOCKS TEMPORARY CHAIN-LINK FENCE ROCK SOCK TEMPORARY CHAIN-LINK FENCE ROCK SOCK SIDE VIEW CF 1.CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. 2.VEHICLE TRACKING CONTROL IS REQUIRED IF ACCESS TO CONCRETE WASHOUT AREA IS OFF PAVEMENT. 3.SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. 4.THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. 5.THE CONCRETE WASHOUT SHOULD BE EMPTIED WHEN HALF OF TOTAL HOLDING CAPACITY HAS BEEN REACHED. 6.AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT AN ACCEPTED WASTE SITE. 7.WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. 8.LOCATION OF CONCRETE WASHOUT AREA ON SHEET EC1 IS CONCEPTUAL ONLY. FINAL LOCATION TO BE DETERMINED IN THE FIELD AT CONTRACTOR'S DISCRETION. {\LNOTES:} 3H:1V OR FLATTER SIDE SLOPES \A1;12" MIN 8'x 8' MIN OR AS REQUIRED TO CONTAIN WASTE CONCRETE \A1;12" \A1;2'-0" MIN. COMPACTED EMBANKMENT MATERIAL, TYP. BERM AROUND PERIMETER GROUND SURFACE SIGN TO INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA CWA * IMPERMEABLE LINER MAY BE NEEDED IF GROUND WATER IS ENCOUNTERED. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner SWALE WATTLE DIKE ENTRENCH 3" POINT A %%USECTION A-A POINTS A MUST BE HIGHER THAN POINT B %%UPLAN VIEW POINT B POINT A WATTLE POINT A FLOW POINT B POINT A WATTLE DIKE {DITCH INSTALLATION} A A THE CONTRACTOR SHALL INSPECT DIKES EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT UPSTREAM SEDIMENT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF DIKES SHALL BE REMOVED WHEN THE UPSTREAM SEDIMENT REACHES 1/2 OF THE DESIGN DEPTH. DIKES ARE TO REMAIN IN PLACE UNTIL THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. WHEN REINFORCED ROCK BERMS ARE REMOVED, ANY DISTURBED AREA SHALL BE SEEDED, CRIMPED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. {MAINTENANCE NOTES: }1. 2. 3. 4. STAKES SHOULD BE DRIVEN ACROSS FROM EACH OTHER AND ON EACH SIDE OF THE WATTLE. LEAVING 4"-6" OF STAKE PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR NYLON ROPE SHOULD BE TIED TO THE STAKES ACROSS THE WATTLE. STAKES SHOULD THEN BE DRIVEN UNTIL THE BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG TO THE WATTLE. STA %%uOR%%u OR (10" MIN. DIA.) 005 C601 NOT TO SCALE WD SIDEWALK CHASE PROPOSED OUTLET STRUCTURE VAULT AREA DETENTION AREA PROPOSED ROOF DRAIN PROPOSED ROOF DRAIN PROPOSED STORM DRAIN PROPOSED 4' CONCRETE PAN PROPOSED 6' CONCRETE PAN PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED STORM DRAIN PROPOSED CULVERT WEST ELIZABETH STREET (80' ROW) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION Project: Union on Elizabeth CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING BEST MANAGEMENT PRACTICES (BMPS) Structural "Installation" Flow Barriers (Bales, Wattles, etc.) (RS) UTILITIES INSTALLATION FLAT WORK INSTALLATION VERTICAL INSTALLATION LANDSCAPE DEMOBILIZATION Concrete Washout Area (CWA) * All Temporary BMPs to be Removed once Construction is Complete Vehicle Tracking Pad * (VTC) Construction Fence (CF) NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 BENCHMARK NOTE: ALL BMPS SHOWN ON THIS PLAN ARE GRAPHIC REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND DOCUMENTED ON THE DYNAMIC SITE PLAN. 1. CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2. TOTAL DISTURBED AREA = 2.29 ACRES 3. SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone________________________________ 4. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 5. REFER TO THE FINAL DRAINAGE REPORT FOR UNION ON ELIZABETH, DATED AUGUST 16, 2017, BY NORTHERN ENGINEERING, FOR ADDITIONAL INFORMATION. 6. FOR ADDITIONAL INFORMATION SEE SEPARATE STORMWATER MANAGEMENT PLAN / EROSION CONTROL REPORT FOR UNION ON ELIZABETH. GENERAL NOTES: LEGEND: 4953 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET VEHICLE TRACKING CONTROL PAD CONSTRUCTION FENCE w/ ROCK SOCK CF CONCRETE WASHOUT ROCK SOCK CWA RS VTC CF PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 20-97 AT THE SOUTHWEST CORNER OF WEST ELIZABETH AND CONSTITUTION AVE. ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.=5050.15 CITY OF FORT COLLINS BENCHMARK 19-97 AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE TRAFFIC SIGNAL BASE. ELEV.=5025.74 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.18' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE NORTH LINE OF LOT 4 AS BEARING SOUTH 88°52'58" EAST. WATTLE DIKE WD No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 14 of 17 C600 EROSION CONTROL PLAN A. Reese B. Ruch 1"=20' 1. IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL AUTHORITIES. 2. THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR EXACT LOCATION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND FOLLOWED. 4. CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE STABILIZATION. 5. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL STORM DRAINS, SWALES, PONDS AND RAIN GARDENS UNTIL SITE IS FULLY STABILIZED. 6. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS ESTABLISHED WITH DOWNSPOUT. 7. INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.) 8. CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS, TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE. 9. CONTRACTOR IS RESPONSIBLE FOR PREVENTING SEDIMENT FROM UNSTABILIZED LANDSCAPE AREAS FROM MIGRATING ONTO AND ENTERING THE PERMEABLE PAVER SYSTEMS UNTIL UPGRADIENT TRIBUTARY AREAS ARE FULLY STABILIZED. 10. ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO ENSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. WATTLES SHALL BE PROVIDED AROUND BUILDING PAD SIDES TO ENSURE AT NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS. 11. CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.) 12. FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. 13. CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS (CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND CONSTRUCTION TOILETS SHALL BE STAKED DOWN. 14. THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE. 15. WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS) INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION CONTROL STAFF TO PREVENT EROSION. 16. CONTRACTOR SHALL EXERCISE CAUTION TO PROTECT RAIN GARDENS AND MODIFIED RAIN GARDEN FROM SEDIMENTATION. THIS INCLUDES EDUCATING SUBCONTRACTORS ON-SITE. 17. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING, REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION METHODS. 18. DIRT AND DEBRIS FROM CONSTRUCTION ACTIVITIES TRACKED ON CITY STREETS SHALL BE KEPT TO A MINIMUM AND CLEANED NIGHTLY OR AT THE SUGGESTION OF THE CITY'S EROSION CONTROL INSPECTOR. 19. CONTRACTOR SHALL KEEP CONSTRUCTION VEHICLES ENTERING AND EXITING SITE TO A MINIMUM. EROSION CONTROL NOTES: NOT TO SCALE 401 C503 STANDARD DRIVEWAY APPROACH NOT TO SCALE 402 C503 DRAINAGE UNDER SIDEWALK NOT TO SCALE 403 C503 NOT TO SCALE 404 C503 6" 2"R. 2" 6" 6" 12" 1 1/2"R. 2'-6" 6" 4 1/2" 30" 9" R 0.5" 4.5" 18" 3.63" 21.75" R 0.13" 7" 2" 3.75" 12" ROLL-OVER VERTICAL (LOVELAND) Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) DATE: 03/01/02 CURB AND GUTTER URBAN AREA STREET STANDARDS LARIMER COUNTY CONSTRUCTION DRAWINGS REVISION NO: 1 701 DRAWING NOTES: 1. 6' wide pan for residential streets. 2. All intersections to have access ramps. 3. Standard Curb and Gutter Section, See Standard Drawing 701 4. 0" Curb Height, See Section A-A 5. All of these pedestrian improvements shall be in ROW or a pedestrian or public access easement. 6. Detectable Warning to extend the full width of the ramp and be 2'-0" in the direction of travel. Maximum slope in the direction of travel shall be no more than 5.0 percent (1:20). Material to be approved by local engineer 7. T = 6" for residential and 8" for commercial. 8. Distance from back of curb to the beginning of Detectable Warning cannot be greater than 5'-0" TYPE III DETACHED WALK N.T.S. SECTIONS A-A CLASSIFICATION APPROACH TYPE Single Family 12' 24' Commercial I, II, III, or IV Multi Family 24' 36' 24' 36' MINIMUM WIDTH WIDTH MAXIMUM Industrial 24' 36' I, II, III, or IV I or II RESIDENTIAL: * * * * * DRIVEWAY WIDTHS LARIMER COUNTY DRAWINGS CONSTRUCTION REVISION NO: 1 707.DRAWING 1 STREET STANDARDS URBAN AREA DATE: 02/17/15 STANDARD DRIVEWAY APPROACH (HIGH VOLUME DRIVE TYPE III) High volume driveways (Type III or IV) allowed for 350 or greater trip ends/day. * 30' maximum for 3 car garages. * *No single opening shall exceed 36'. Wider driveways shall be divided w/a median not less than 6' wide. 1/4" per ft. 1" per ft. 1:50 Slope  T Walk 1:50 1:12 (max.) Gutter Parkway Sidewalk Detached 1:12 A A (max) 2' Flare See Note 4 See Note 3 If Concrete Driveway Expansion Joint NOT TO SCALE See Note 6 1/4" per ft. 1" per ft. 1:12 (max.) 1" per ft. Driveway FL See Note 8 I, II, III, or IV Sidewalk Detached or equivalent. (typical both sides) With curb walk, cover plate extends from property line to top of walk face. 6" VERTICAL CURB, GUTTER, AND SIDEWALK SECTION A-A (2 VIEWS) COMBINATION CURB, GUTTER, AND SIDEWALK center, Nelson Standard Anchor 3" #4 Bar Welded at 12" on L = 1 1/4" x 1 1/4" x 1/4" 5/8" Rolled Steel Tread Plate SECTION C-C 1.0' (minimum) approved by the Engineer. Right of Way line to flow line unless 2. Chase and cover plate run from 1. Length of steel plate varies. Notes: Dimension Variable (diamond pattern) 5/8" Rolled Steel Tread Plate 4'-0" or as Directed Retaining Screws at Top of Curb C B A C B PLAN VIEW A Street 10 3/8" SECTION B-B 6" 1 1/4" STANDARD DETAILS FOR DRAINAGE UNDER SIDEWALK STREET STANDARDS LARIMER COUNTY URBAN AREA CONSTRUCTION DRAWINGS DATE: REVISION 04/NO: 01/07 1 709 DRAWING Attached Ft. Collins only Detached Sidewalk finish 12" on center Screw Brass or Electro-galv. 1/2" x 1" Flat Head Mach. threaded to receive screw. Angle iron to be drilled and screw to extend into the Concrete to be drilled to allow Lip of Gutter concrete (typical both sides). (typical both sides) F L Sidewalk X (Varies, See Plans Xmax=2.0') d (Varies, See Plans) ATTACHED SIDEWALK DETAIL Slope sidewalk to curb 1/4" per foot. NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4" 1/4 SLAB THICKNESS 1/4" 1/2" Expansion Joint material DETACHED SIDEWALK DETAIL Variable Landscaping Slope sidewalk to curb 1/4" per foot. 2' min. Slope: Minumum 1 4"/ft Maximum 3"/ft CONSTRUCTION SIDEWALK DETAIL LARIMER COUNTY STREET URBAN STANDARDS AREA DRAWINGS 1602 DRAWING REVISION DATE: 04/NO: 01/07 2 02/17/15 STANDARD SIDEWALK URBAN AREA STREET STANDARDS LARIMER COUNTY CONSTRUCTION DRAWINGS REVISION NO: 1601 DRAWING DATE: 4 Driveway Driveway Sidewalk SECTION A-A Detached Sidewalk Attached Sidewalk Detached Attached All Sidewalk Thickness Shall Be 6" minimum. Sidewalk NOTE: 1. Sidewalk grade shall remain consistent across driveway 2. For driveway design requirements, see CONST. DWG. Series 706 & 707 3. This detail applies to Residential & Commercial driveways. 6" 2'-0" 6'-0" T.C. F.L. Lip 1/2" Expansion Joint Material 1/2" Expansion Joint Material 8" Commercial 6" Residential A A Sidewalk Min. NOT TO SCALE STANDARD SIDEWALK SIDEWALK DETAIL CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOT TO SCALE 414 C503 5" TRENCH DRAIN MINIMUM 0.5' DEPTH VARIES PER PLANS MINIMUM 0.5' MINIMUM 0.25' TO BE MONOLITHICALLY POURED WITH ADJACENT CONCRETE MINIMUM 1' VARIES PER PLANS 0.5' 1' - 5" 5" NOTES: ALL SITE GRADING, SUBGRADE PREPARATION AND PAVING SHALL FOLLOW THE GEOTECHNICAL RECOMMENDATIONS CONTAINED IN THE "GEOTECHNICAL ENGINEERING REPORT ELIZABETH STREET PROJECT 1208 AND 1220 WEST ELIZABETH STREET, FORT COLLINS, COLORADO" PROJECT NO. 20165099 DATED NOVEMBER 18, 2016, AND ANY SUBSEQUENT ADDENDA. 1. REFER TO PLANS BY RIPLEY DESIGN, INC. FOR ADDITIONAL HARDSCAPE INFORMATION. 2. CONCRETE JOINTING SHALL CONFORM TO CDOT DETAIL M-412-1 OR APPROVED EQUAL. 3. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR PAVER SECTION AND INSTALLATION. (NOTE: SECTION SHALL MEET THE SAME STRUCTURAL REQUIREMENTS AS 'HEAVY DUTY' ABOVE) 4. THE ENTIRE PERIMETER OF THE PERMEABLE PAVER AREAS SHALL RECEIVE SOME FORM OF EDGE RESTRAINT. FOLLOW MANUFACTURER'S RECOMMENDATIONS AND DETAILS ON THIS SHEET. 5. NOTE THAT THESE PAVING SECTIONS ARE TO BE USED ONLY FOR AREAS OUTSIDE OF PUBLIC RIGHT-OF-WAY. PAVING SECTIONS WITHIN PUBLIC RIGHT-OF-WAY WILL BE REQUIRED BY THE CITY OF FORT COLLINS TO BE PER AN APPROVED PAVEMENT DESIGN REPORT. THICKENED CONCRETE EDGE 4" CONCRETE PRIVATE CONCRETE FLATWORK PAVEMENT SECTION NOT TO SCALE 405 C503 PERMEABLE PAVER SECTION 2" BEDDING SUB-BASE DEPTH VARIES 27"-39" (SEE SHEET G2) SUB-GRADE 1 4" JOINTS HAND TIGHT 4" BASE FILTRAPAVE (31 8" DEPTH) \A1;12" \A1;10" NOT TO SCALE 413 C503 12" BARRIER CURB {\L12" EDGE RESTRAINT} 4000 PSI CONCRETE 1'-6" R2" 6" 41 2" 11 2" 6" R1 1/2" 13 8" 6" 12" INFALL SECTION 1'-6" R2" 6" 41 2" 11 2" 6" R1 1/2" 13 8" OUTFALL SECTION 6" 12" PRIVATE 18" VERTICAL CURB & GUTTER NOT TO SCALE 411 C503 2' 6" CURB NOT TO SCALE 410 CURB CUT C503 1' 1' 6" 2' 1 1/2" 1' 1' NOT TO SCALE 412 C503 2' CONCRETE PAN 4" 4" R2" 4" 4" R2" 6" OUTLET PIPE FRONT VIEW SIDE VIEW NOT TO SCALE 409 C503 CONCRETE COLLAR (PRIVATE ON-SITE) 6" 2' 4' 2' NOTE: PROVIDE CONTROL JOINTS AT 10' INTERVALS. SLOPE 1"/FT. SLOPE 1"/FT. NOT TO SCALE 407 C503 4' CONCRETE CROSS PAN (PRIVATE ON-SITE) 6" 3' 6' 3' NOTE: PROVIDE CONTROL JOINTS AT 10' INTERVALS. SLOPE 1"/FT. SLOPE 1"/FT. NOT TO SCALE 408 C503 6' CONCRETE CROSS PAN (PRIVATE ON-SITE) 6" CONCRETE PUBLIC CONCRETE FLATWORK PAVEMENT SECTION CONCRETE FLATWORK SECTIONS VEHICULAR PAVING SECTIONS 36" MINIMUM d 0.2d OR 2" MIN.** **FOR AREAS ADJACENT TO PERMEABLE PAVING, THICKENED EDGE SHALL BE A MINIMUM OF 10" THICK. ASPHALT PAVEMENT SECTION 6" HOT BITUMINOUS PAVEMENT (S OR SX) LIGHT DUTY PAVING ASPHALT PAVEMENT SECTION HEAVY DUTY PAVING 7" HOT BITUMINOUS PAVEMENT (S OR SX) 7" APPROVED SUBGRADE 8" APPROVED SUBGRADE 4" HOT BITUMINOUS PAVEMENT (S OR SX) 5" HOT BITUMINOUS PAVEMENT (S OR SX) PAVING SECTIONS NOT TO SCALE 406 C503 Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C502 STORMWATER DETAILS A. Reese B. Ruch NTS CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOT TO SCALE 300 C502 STORMWATER BEDDING NOT TO SCALE 301 C502 CURB, GUTTER AND SIDEWALK CLASS B BEDDING LOWER LIMIT OF UNIFORM GRADED CLASS A BEDDING LOWER LIMIT OF LOWER LIMIT OF MATERIAL TRENCH WIDTHS SHALL BE AS SPECIFIED ON PLANS. REFER TO THE STORM SRAINAGE CONSTRUCTION STANDARDS, SECTION 6, "BEDDING MATERIALS" FOR GRADATIONS. SUBDRAIN DETAIL TRENCH WIDTH AS SPECIFIED TRENCH WIDTH AS SPECIFIED ROCK EXCAVATION TRENCH WIDTH AS SPECIFIED GRANULAR MATERIAL UNSTABLE SUBGRADE TRENCH WIDTH AS SPECIFIED ROCK 1 1/2 IN. COMPACTED GRANULAR OR TRENCH WALL SLOPE COMPACTED MATERIAL GRANULAR %%UNOTES: 2. 1. 6 IN. MIN. 4 IN. MIN. \A1;1/8 PIPE O.D. OR 4 IN. MIN. SLOTTED PIPE PERFORATED OR GRAVEL FILTER BACKFILL COMPACTED DENSELY TRENCH WIDTH AS SPECIFIED CLASS C BEDDING TRENCH WIDTH AS SPECIFIED \A1;1/4 PIPE O.D. SLOPE MATERIAL COMPACTED TRENCH DENSELY WALL \A1;PIPE O.D. + 8 IN. \A1;1/4 PIPE O.D. MATERIAL COMPACTED DENSELY SLOPE TRENCH WALL MATERIAL \A1;PIPE O.D. OR 6 IN. MIN. \A1;1/8 PIPE O.D. 3000 CONCRETE P.S.I. TRENCH WALL LOWER LIMIT OF UNIFORMLY SELECTED GRADED SLOPE GRADED COMPACTED ROCK OR MATERIAL GRANULAR COMPACTED \A1;PIPE O.D. TRENCH WALL LOWER LIMIT OF SLOPE COMPACTED DENSELY FILTER 6 IN. MIN. \A1;PIPE O.D. \OR A1;4 1/IN. 8 PIPE MIN. O.D. \A1;PIPE O.D. BROKEN LARGE (IF CONCRETE, REQUIRED) STONES, ETC. MATERIAL LOWER LIMIT OF TRENCH WALL SLOPE APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 STORMWATER BEDDING REQUIREMENTS 1/12/00 D-1 SKC APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 CURB, GUTTER AND SIDEWALK DETAILS 11/13/00 D-6 NBJ DRIVE-OVER CURB, GUTTER AND SIDEWALK VERTICAL 6 IN. CURB, GUTTER AND SIDEWALK DUMMY JOINT FOR WALKS COMBINATION CURB, GUTTER AND SIDEWALK "HOLLYWOOD" (OBSOLETE - FOR REPLACEMENT ONLY) EDGED 1/8 IN. R. 1/8 IN. 3/4 IN. MIN. SURFACE 4 FT. MIN. .30 FT. 6 IN. .11 FT. .09 FT. 4.43 FT. 1.18 FT. .58 FT. 2.67 FT. 6 IN. 12 IN. 6 IN. 2 FT 6 IN. 2 IN. 6 IN. 1 1/2 IN. 4 1/2 IN. 1 1/2 IN. R 2 IN. R WHERE WALK ADJOINS A CURB, IT SHALL BE CONSTRUCTED 1/4 INCH ABOVE THE CURB. SLOPE SIDEWALK TO CURB - 1/4 IN. TO 1/2 IN. PER FT. 6 IN. 1 3/8 IN. (.11 FT.) 3 3/8 IN. (.28 FT.) 18 IN. (1.5 FT.) (1.5 FT.) 18 IN. (1.17 FT.) LIMITS OF C & G (1.42 FT.) (3.75 FT.) 3 FT. 9 IN. FLOW LINE (1.33 FT) 16 IN. R (1.33 FT.) 16 IN. R 6 IN. 1 1/2 IN. NOT TO SCALE 303 C502 ORIFICE PLATE (CONCRETE OUTLET STRUCTURE) ORIFICE OPENING (3.5" Ø) PLATE CENTERED OVER PIPE OPENING IN WALL 1 2" Ø HOLES FOR 3 8" Ø EXPANSION BOLTS EMBEDDING 2" INTO CONCRETE WALL @ 6" O.C. MIN. 5 16" THICK GALVANIZED STEEL PLATE D D+4" D+4" ORIFICE INVERT SHALL MATCH PIPE INVERT 120° 90° 60° A \A1;C \\A1;B A1;D SCREEN SLOT TABLE A B C D E F PIPE SIZE ROWS OF SLOTS SLOT LENGTH MAXIMUM SLOT WIDTH APPROX. SLOT/ROW PER FOOT APPROX. SLOT SPACING OPEN AREA PER FOOT 6" 3 (MIN.) - 6 (MAX.) 1.38"-2.35" 0.032" 14 1/2"-3/4" 1.98-3.15 SQ. IN. NOTES: 1. "SLOTTED HDPE" AND "PERFORATED HDPE" SHALL MEAN THE SAME THING WHEN REFERRING TO UNDERDRAINS IN THIS PLAN SET. 2. ALTERNATE SLOT DIMENSIONS AND PERFORATIONS REQUIRE EXPLICIT APPROVAL OF THE ENGINEER. NOT TO SCALE DIMENSIONS FOR SLOTTED HDPE PIPE NOT TO SCALE 307 C502 CONCRETE OUTLET STRUCTURE PRIVATE UNDERDRAIN BASIN 4" MIN EXTEND MIN. 6" INTO SUBGRADE 6" VARIES (REFER TO STORM DRAIN PLAN) INTEGRATED DUCTILE IRON FRAME & SOLID GRATE TO MATCH BASIN O.D. NOTES: 1 - GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS SEE DRAWING NO. 7001-110-065 4 - PERFORATIONS SHOULD NOT BE ON OR WITHIN 1" OF ADAPTERS. 5 - HOLES SHOULD BE STAGGERED EVERY OTHER ROW, AS SHOWN. 6 - MIN. 90° SEPARATION BETWEEN HOLES (MAX. 4 HOLES PER ROW) 2" MIN Ø .375" MAX SIDE VIEW HOLE SIZE & LOCATION NTS ENLARGED TO SHOW DETAIL 6" THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. TOP 10" TO BE SOLID, WITHOUT PERFORATIONS 10" SOLID TOP NO PERFORATIONS WITHIN 1" OF ADAPTORS OPEN BOTTOM (NO BOTTOM CAP) NOT TO SCALE 308 C502 8" MIN. THICKNESS GUIDELINE 12" MIN WIDTH GUIDELINE 3/8 IN. BRASS SCREW-18 IN. O.C. W/ COUNTERSUNK HEAD FLUSH W/ PLATE 5/8 IN. GALVANIZED PLATE ANCHOR-18 IN. O.C. NO. 3 REBAR ANGLE GALVANIZED 3x2x3/8 IN. 3 IN. 2 FT. 0 IN. 3 IN. 3 IN. 2:1 SLOPE 3 FT. 0 IN. 5 FT. 6 IN. 4 5/8 IN. 6 IN. MIN. 7 1/2 IN. 2:1 SLOPE PLACE FIRST SCREW SEE DETAIL "A" OF PLATE 6 IN. FRONT EDGE 10 FT. 0 IN. RAISED PATTEREN NON-SKID GALV. 5/8 IN. X 2 FT. 6 IN. X 4 FT. 6 IN. STEEL PLATE (AASHTO M-111) SECTION A-A 1/2 IN. FLOWLINE (AS SHOWN ON PLANS) 6 IN. 2 FT. 0 IN. 4 FT. 6 IN. SLOPE PLATE TO MATCH SIDEWALK 6 IN. 4 FT. 0 IN. 6 IN. FL APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 NBJ 12/12/00 D-10 METAL SIDEWALK CULVERT FOR VERT. CURB & GUTTER AND SIDEWALK DETAIL "A" PLAN VIEW A A B B x x x x x x x x x x x x x x x x x x x MIN. SECTION SECTION B-B NOT TO SCALE 302 C502 METAL SIDEWALK CULVERT NOT TO SCALE 304 C502 NOT TO SCALE 305 C502 POND OUTLET WALL 5029.21 5030.21 5031.21 5033.00 4' 4' 12" N/A N/A N/A N/A CAD FILE NAME: DETAILS (MODIFIED) DRAWN BY: T. COX D46.dwg OUTLET STRUCTURE DATE DRAWN: 8/15/05 C C A A 1' Ls 3'-6" (MIN.) 6" Ws 6" 6" VARIES VARIES 6" Ws/2 Ws/2 CENTERLINE OF OUTLET PIPE 2" LIP (TYP.) SECTION C-C SECTION A-A WELL SCREEN #4@12" #4@12" #4@18" #4@12" 6" Wo Wo INTO CONCRETE SIDES STEEL CHANNEL FORMED 3/8"x1" FLAT BAR HOLDING FRAME INTERMITTANT WELDS ON TOP AND SIDES STAINLESS STEEL ANCHOR BOLTS OR 51"x51" GRATING (3/8" ROUND OR TWISTED CROSS BARS AT 3" O.C., WELDED TO 1"x3/8" BEARING BARS AT 2 1/2" O.C.) 3/8" ROUND OR TWISTED CROSS BAR BAR BEARING 1"x3/8" PLAN 3" CLR. TO FASTEN GRATE DOWN 3/8"x6" THREADED BOLT D 1 4 OR 3 4. ALL TRASH RACKS SHALL BE MOUNTED USING STAINLESS STEEL HARDWARE AND PROVIDED WITH HINGED AND LOCKABLE OR BOLTABLE ACCESS PANELS. 5. TRASH RACKS SHALL BE STAINLESS STEEL, ALUMINUM, OR STEEL. STEEL TRASH RACKS SHALL BE HOT DIP GALVANIZED AND MAY BE HOT POWDER PAINTED AFTER GALVANIZING. 3 1/2" x1 1/2" KEY OUTLET PIPE 4% 4% CLR. 3" BAR #4 HOOP PIPE CONCRETE METAL OR F L LAP 12" #4@12" O.C. O.C. #4@12" CONCRETE SHALL BE CLASS B. MAY BE CAST-IN-PLACE OR PRECAST. GENERAL NOTES 1. 2. 3. STEPS SHALL BE PROVIDED WHEN VERTICAL DIMENSION EXCEEDS 3'-6" AND SHALL BE IN ACCORDANCE WITH AASHTO M 199. HAVE A MINIMUM 2" CLEARANCE. REINFORCING BARS SHALL BE EPOXY COATED AND DEFORMED, AND SHALL #4 DIAGONAL (TYP.) SECTION B-B ELEV. B ELEV. A ELEV. C WQ WATER QUALITY 100-YEAR OUTLET ORIFICE PLATE B B ELEV. A (POND INV.) ELEV. B ELEV. C SPILL ELEV. WQ HOLE DIA. # OF ROWS # OF COLUMNS SECTION LINE A-A (ARROWS POINT IN DIRECTION SECTION IS VIEWED) A A OPP. OPPOSITE CLR. CLEARANCE ABBREVIATIONS MINIMUM MAXIMUM ON CENTER DIAMETER TYPICAL WIDTH OF CONCRETE OPENING WIDTH OF PLATE NUMBER @ AT # Wp Wo TYP. DIA. O.C. MAX. MIN. LEGEND WQ WATER QUALITY DWQ INV. INVERT ELEV. ELEVATION 6" Ls Ws 6" Ls LENGTH OF STRUCTURE Ws WIDTH OF STRUCTURE Wo (12" MIN.) STEEL OR EQUAL) (NOTE 5) TRASH RACK (U.S. FILTER STAINLESS WELL SCREEN NO. 93 TRASH RACK STEEL OR EQUAL) (U.S. FILTER STAINLESS WELL SCREEN NO. 93 EQUAL) FILTER STAINLESS NO. 93 (U.S. WELL SCREEN STEEL OR DETAIL LAST DATE REVISED: 4/7/11 D-46 3/8"x6" THREADED BOLT TO FASTEN GRATE DOWN GRATE (TYP. OPP. SIDE) 2 1/4" FROM EDGE OF TO HOLD HINGE IN PLACE, 3/8"x6" BOLTS 12" O.C. TO COVER OPENING (FASTEN WITH 3/8"x6" 1/4" METAL PLATE TREADED BOLTS) TO GRATE, WITH TO GRATE, WITH (TYP. OPP. SIDE) GRATE (TYP. OPP. SIDE) 2 1/4" FROM EDGE OF TO HOLD HINGE IN PLACE, 3/8"x6" BOLTS 12" O.C. 1/4" PLATE, WELDED 1/4" PLATE, WELDED STORMWATER CONSTRUCTION DETAILS (970) 221-6700 P.O. BOX 580, FORT COLLINS, CO. 80522 CITY OF FORT COLLINS UTILITIES EXTERIOR WALL NOT TO SCALE 305 C502 BIO-SWALE SECTION / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / MIN. 8" GRAVEL LAYER MEETING CDOT #4 COARSE AGGREGATE SPECIFICATION COBBLE SWALE 8" BIO-RETENTION SAND MEDIA MIN. 6" PEA GRAVEL NOTES: 1. REFER TO THE CITY OF FORT COLLINS BIORETENTION SAND MEDIA SPECIFICATION FOR MORE INFORMATION ON THE SOIL MIX. 2. BIORETENTION SAND MEDIA SHALL BE PROVIDED BY HAGEMAN EARTH CYCLE OR APPROVED EQUAL. 3. REFER TO LANDSCAPE PLANS BY RIPLEY DESIGNS, INC. FOR ADDITIONAL INFORMATOIN REGARDING COBBLE, SWALE PLANTINGS, ETC. 2'-0" CLASS III CDOT DRAINAGE GEOTEXTILE 12" MIN. FFE-FG Building FFE CONCRETE ALLEY 12" MIN. FL-FG WALK 2' 2' - 4" 2' CHASE (DETAIL D-10) 0.5 (MIN.) % CONCRETE WALL WALK 6" 0.5 (MIN.) % WATER QUALITY PLATE ORIFICE PLATE WATER QUALITY PLATE 6" 12" 4" (TYP.) 1' (MAX.) ORIFICE PLATE 6" 12" 1' (MAX.) 6" ORIFICE OPENING AT INVERT OF PLATE (3.5" Ø) BOTTOM HOLE TO BE AT INVERT OF PLATE STAINLESS STEEL ANCHOR BOLT (TYP.) 1 4" (MIN.) THICK STEEL PLATE 1 4" (MIN.) THICK STEEL PLATE 1 8" Ø WATER QUALITY HOLE (TYP.) STAINLESS STEEL ANCHOR BOLT (TYP.) GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 11 of 17 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL NOT TO SCALE Environmental Planner 204 C501 BEDDING REQUIREMENTS NOT TO SCALE 205 C501 STANDARD MANHOLE COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 LOWER LIMIT OF TRENCH WALL SLOPING INITIAL LIFT * 12 IN. MIN. PIPE O.D. 4 IN. MIN. TRENCH WIDTH AS SPECIFIED IN SECTION 02221 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 * DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL BEDDING REQUIRMENTS WW-1 NBJ 4/11/11 ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE 2 IN. MIN. SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 18 IN. TO 30 IN. 60 IN. OVER 30 INCHES 72 IN. MIN. MANHOLE MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE 5 FT. MIN. DEPTH CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 30 IN. MIN. 48 IN. MAX. VARIABLE 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL STANDARD MANHOLE WW-3 NBJ 4/11/11 NOT TO SCALE 206 C501 TRAFFIC RATED CLEANOUT W/ SEWER STAMPED ON LID VALVE BOX \A1;6" MIN \A1;WATER TIGHT SCREW CAP \A1;4" HARD ASPHALT SURFACE OR OTHER FLOW DIRECTION DATE REVISED: SEWER CONSTRUCTION DETAILS APPROVED: DRAWN BY: DETAIL TRAFFIC RATED CLEANOUT WW-15 NBJ 4/11/11 CP TEST STATION U S A \A1;1 1/8" 7/16" 3 1/2" 7 5/16" 5/2" 8" A S U I E J W STATION LOCATOR LID PLAN VIEW LID SECTION VIEW VALVE BOX SECTION VIEW 9" 6 1/8" 10" \A1;7 9/16" 2 1/16" CLOSED PICKHOLE (TYPICAL OPPOSITE SIDE) 1/2" RAISED LETTERING (RECESSED FLUSH) REFERENCE SPECIFICATIONS 02622-2 THROUGH 02622-4 FOR LOCATOR FOR CP TEST STATION INFORMATION. REFERENCE SPECIFICATIONS 16640-5 STATION BOX INFORMATION. REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 CP TEST AND LOCATOR STATION BOX 25 W J E I NOT TO SCALE 203 C501 CP TEST AND LOCATOR STATION BOX GENERAL NOTES: 1/4" HOLE IN HANDLE 1 1/2" BALL VALVE 6. %METER %INSTALLATION UPLAN DESIGN FOR 6 VIEW IN. AND LARGER METERS SHALL BE DETERMINED BY THE 1 1/UTILITY. 2" CAP 5. FOR IRRIGATION ONLY SERVICES, NO BYPASS ALLOWED. 4. 3. GATE VALVES MUST OPEN RIGHT AND BE EPOXY COATED, RESILIENT SEAT WITH A HAND WHEEL ASSIST. ALL PIPING WITHIN VAULT SHALL BE D.I.P. WITH FLANGED FITTINGS, EXCEPT FOR THE SOLID SLEEVES. 2. ALL JOINTS OUTSIDE OF VAULT SHALL BE RESTRAINED MECHANICAL JOINTS. (REFERENCE SECTION 02615) 1. THE BUILDING IMMEDIATELY FOLLOWING THE MAIN SHUT OFF VALVE. IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, INSTALL VALVE INSIDE 7. LOCATION AND ALIGNMENT OF AMR POD(S) ON VAULT TOP CAN VARY. %%UTEST-TEE SIDE VIEW SEE DETAIL TEST-TEE BELOW LID) 24" DIA. FOR H-20 BRIDGE LOADING PRECAST CONCRETE VAULT DESIGNED STRAINER 7'-0" 1'-6" 2'-6" METER (PLACED FLOW SLEEVE SOLID VALVE VALVE GATE GATE SLEEVE SOLID 8'-6" AMR POD(S) (FORD YOKE BOX PART #YUC-7 WITH FORD YOKE BOX LID PART #YL-TP WITH 1 27/32" DIA. HOLE AND REMOVABLE PLUG) ANCHOR RODS PROTECTIVE COATING (TYP.) WITH GATE VALVE FLOW FLOW FLOW ACCESS OPENING LADDER RUNG VAULT ACCESS PRECAST CONCRETE OR FOOTING CAST IN PLACE 18" DIA. PERFORATED PIPE SUMP 8. A SEPERATE AMR POD MUST BE INSTALLED FOR EACH METER REGISTER. REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (PLAN VIEW) 17A 4/11/11 1. DO NOT INSTALL IN ANY STREET, ALLEY, PARKING AREA, DRIVEWAY, SIDEWALK DRAINAGE DITCH OR DETENTION BASIN. 2. NO LANDSCAPING (SHRUBS, BOULDERS, ECT.) OR STRUCTURES TO BE WITHIN 4 FT. OR TREES WITHIN 10 FT. OF METER VAULT. 3. SLOPE GROUND SURROUNDING METER VAULT AWAY FROM LID AT 2%%% GRADE OR GREATER. 4. MAKE NO PLUMBING CONNECTIONS (TEES, COUPLINGS, ECT.) IN METER VAULT. 5. GRADE ACCEPTANCE AFTER METER PIT INSTALLATION REQUIRES THAT THE OWNER ADJUST METER VAULT COVER TO 1/2 IN. ABOVE FINAL GRADE. 6. IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, IT SHALL BE INSTALLED INSIDE THE BUILDING, IMMEDIATELY FOLLOWING THE MAIN SHUT-OFF VALVE. GENERAL NOTES: ADJUSTABLE PIPE SUPPORT UNDER VALVES AND METER 3/4" TO 1-1/2" GRAVEL ASPHALTIC GROUT SOLID PAVING BRICK (TYPICAL) PRE-FORMED PLASTIC GASKETS PIPE ENCASED WITH MASTIC GATE VALVE STRAINER SOLID SLEEVE GATE VALVE MANHOLE RUNGS 12 INCHES O.C. FINISHED GRADE 2% SLOPE INSTALL LID 1/2" ABOVE FINAL GRADE ALUMINUM MANHOLE COVER AND RING WITH LID LOCK MORTAR OR LIFTING HOOK MASTIC FLOW BLOCK-OUT TO BE GROUTED 54" (MIN.) 6" (MAX.) 7" (MIN.) 16" (MAX.) GRADE PRE-RINGS CAST CONCRETE (IF REQUIRED) 10" 30" 8" 8" (TYPICAL) ANCHOR RODS (TYP.) WITH PROTECTIVE 1" (MAX.) CONDUIT THROUGH INTO YOKEBOX VAULT OR PIT TOP 1/2" EMT OR PVC 3" (MAX.) AND REMOVABLE PLUG) YOKE WITH PART BOX #1 YUC-27/LID 32" 7 PART WITH DIA. HOLE FORD #YL-TP AMR POD (FORD YOKE BOX FINISHED GRADE BE 1/2" ABOVE TOP OF AMR LID TO 2' 3/4" ROCK FOR GRADE ADJUSTMENT (MAX.) (IF REQ'D) (TYP.) (TYP.) 66" (MAX.) 12" (TYP.) PRECAST OR CAST IN PLACE CONCRETE FOOTING (TYP.) PIPE 18" SUMP DIA. PERFORATED REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (SIDE VIEW) 17B 4/11/11 COATING SERVICE LINE BY-PASS 30" 54" (MIN.) 8" 8" 10" 6" (MAX.) 12 INCHES MANHOLE O.RUNGS C. AND RING WITH LID LOCK ALUMINUM MANHOLE COVER MORTAR OR MASTIC PRE-CAST GRADE CONCRETE RINGS (IF PLASTIC GASKETS PRE-FORMED LIFTING HOOK REQUIRED) 3/4" TO 1-1/2" GRAVEL PRECAST OR CAST IN PLACE CONCRETE FOOTING (TYP.) (TYP.) 66" (MAX.) 12" (TYP.) REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (END VIEW) 17C 4/11/11 NOT TO SCALE 200 C501 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (PLAN VIEW) NOT TO SCALE 201 C501 NOT TO SCALE 202 C501 STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (SIDE VIEW) STANDARD SETTING FOR 3 IN. AND 4 IN. WATER METERS (END VIEW) GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 10 of 17 NOT TO SCALE 100 C500 WATER MAIN BEDDING BOTTOM OF PIPE AND A MINIMUM OF 12 INCHES ABOVE TOP OF PIPE. GRANULAR BEDDING MATERIAL SHALL BE A MINIMUM OF 4 INCHES BELOW INITIAL 12 IN. LIFT MIN. PIPE O.D. 4 IN. MIN. GRANULAR MATERIAL BEDDING ZONE %%UNOTE: * INITIAL LIFT SHALL NOT EXCEED 2 FEET IN DEPTH. TRENCH WALL LOWER LIMIT OF SLOPING TRENCH IN WIDTH SECTION AS 02221 SPECIFIED * REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 WATER MAIN BEDDING REQUIREMENTS (DIP & PVC) 1 4/8/11 PIPE SIZE BENDS TEE OR DEAD END 22 1/2%%D 45%%D 90%%D 6" 8" 12" 1.0 1.5 3.0 1.5 2.5 4.5 2.5 4.5 9.0 4.5 8.0 16.5 3.5 5.5 12.0 MINIMUM BEARING SURFACE AREA (SQ. FT.) Bearing surface areas shown in chart are minimum. All fittings to be wrapped with polyethylene. Pipe installed under conditions different from those normally encountered shall require thrust blocks designed for those particular conditions. Thrust blocks on pipe larger than 16 inches diameter shall be designed for conditions existing at the installation site. Refer to Section 03300 for concrete requirements. 1. 2. 3. 4. 5. GENERAL NOTES: UNDISTURBED SOIL POLYETHYLENE BOND BREAKER UNDISTURBED SOIL BOND BREAKER POLYETHYLENE BEARING SURFACE POLYETHYLENE BOND BREAKER UNDISTURBED SOIL BEARING SURFACE SOIL UNDISTURBED BEARING SURFACE POLYETHYLENE BOND BREAKER BEDDING MATERIAL 2/3 DIA. %%UTEE %%UTYPICAL BEND %%UTYPICAL CROSS-SECTION %%UDEAD END BEARING SURFACES ARE A MINIMUM REQUIREMENT AND DO NOT RELIEVE DESIGN ENGINEER OF RESPONSIBILITY TO DESIGN EACH THRUST BLOCK. 16" 4.8 9.6 18.9 34.7 24.5 REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD CONCRETE THRUST BLOCKS 2 4/8/11 DESIGNATED SPRINKLER SERVICE FLOW 5 FT. MIN. METER PIT AIR-INJECTION PORT (TOP OF PIPE MAX. 1/4" PIT METER 5 FT. MIN. FLOW SPRINKLER TAP OFF DOMESTIC SERVICE SERVICE MAIN VACUUM BREAKER VACUUM BREAKER (FROM OUTLET SIDE OF METER PIT TO SHUT-OFF VALVE TEE) IRRIGATION SHUT-OFF VALVE AIR-INJECTION PORT DOWNSTREAM OF VACUUM BREAKER SPRINKLER TEE) METER PIT TO (FROM OUTLET SIDE OF (STOP AND WASTE VALVE NOT PERMITTED) IRRIGATION SHUT-OFF VALVE (STOP AND WASTE VALVE NOT PERMITTED) DIA. WITH CAP OR PLUG) AIR-INJECTION PORT (TOP OF PIPE MAX. 1/4" DIA. WITH CAP OR PLUG) (3/4" OR LARGER RECOMMENDED) RECOMMENDED) (3/4" OR LARGER PORT DOWNSTREAM OF VACUUM BREAKER AIR-INJECTION REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 SPRINKLER SYSTEM DETAIL 13 8/4/15 NOT TO SCALE 101 C500 STANDARD CONCRETE TRUST BLOCKS NOT TO SCALE 103 C500 SPRINKLER SYSTEM DETAIL Compact trench as required by Development Construction Standard to support valve box. Locate curb box and water meter according to the approved utility drawings. GENERAL NOTES 2. 1. PAVEMENT CURB STOP CURB BOX 66 INCH MAX. 54 INCH MIN. W/ WATER STAMPED ON LID VALVE BOX \A1;8-12" MIN REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 TRAFFIC-RATED CURB STOP INSTALLATION 11A 7/17/2014 NOT TO SCALE 102 C500 TRAFFIC-RATED CURB STOP INSTALLATION NOT TO SCALE 104 C500 DO NOT INSTALL IN ANY STREET, ALLEY, PARKING AREA, DRIVEWAY, SIDEWALK, DRAINAGE DITCH OR DETENTION NO LANDSCAPING (SHRUBS, BOULDERS, ETC.) OR STRUCTURES TO BE WITHIN 4 FEET OF METER BOX, OR SLOPE GROUND SURROUNDING METER BOX AWAY FROM LID AT 2% MINIMUM GRADE. MAKE NO PLUMBING CONNECTIONS (TEES, COUPLINGS, ETC.) IN METER BOX. ALL TEES AND CONNECTION FITTINGS TO BE A MINIMUM OF 5 FEET FROM METER BOX WALL ON OUTLET SIDE. GRADE ACCEPTANCE AFTER METER BOX INSTALLATION REQUIRES THAT THE OWNER ADJUST METER BOX COVER TO 1/2 INCH ABOVE FINAL GRADE. IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, INSTALL VALVE INSIDE THE BUILDING, IMMEDIATELY FOLLOWING THE MAIN SHUT-OFF VALVE. 1. 2. 3. 4. 5. 6. 7. 14 IN. MIN. ALLOWED CAST IRON FROST PROOF METER BOX COVER COMPRESSION TYPE CONNECTION LOCK TYPE INLET VALVE TYPE "K" COPPER PIPING 48 IN. 10 IN. INSTALL LID 1/2 INCH ABOVE FINAL LANDSCAPED GRADE FLOW METER BOX METER GENERAL NOTES 2 FT. MAX. CURB BOX 64 IN. (NO OR EXTENSIONS) ALTERATIONS CAST IRON RECESSED LID WITH WORM LOCK RUBBER OR PLASTIC INNER LID NO TREES WITHIN 10 FEET OF METER BOX. NO FOR FITTINGS MIN. OF 5 FT. 18 IN. MAX. ALLOWED 15 IN. RECOMMENDED C.L. OF METER CONNECTION 6 INCH LAYER OF GRAVEL (3/4 IN.- 1 1/2 IN.) UNDER METER BOX CURB STOP REVISED DATE: DETAIL TITLE OF DRAWING FIELD OPERATIONS (970) 221-6700 UTILITIES - WATER FORT COLLINS, CO. 80550 CITY OF FORT COLLINS P.O. BOX 580 STANDARD EXTERIOR SETTING FOR 3/4 IN. AND 1 IN. WATER METERS 15 4/11/11 BASIN. STANDARD SETTING FOR 3/4 IN. AND 1 IN. WATER METERS WATER MAIN SEAT VALVE RESILIENT CAST IRON VALVE BOX CAST IRON PER CITY OF FORT COLLINS AND AWWA SPECS. ALL VALVES TO BE 8 MIL POLY WRAPPED. T-BOLTS, NUTS AND RODS ALL VALVE BOXES TO BE OF CAST IRON CONSTRUCTION, TWO PIECE TO BE TAR COATED BEFORE WRAPPED. THREADED ADJUSTABLE DESIGN PER CITY OF FORT COLLINS SPECS. VALVE BOX W\CAST IRON LID MARKED "WATER" ALL VALVES TO BE RESILIENT SEAT, EPOXY COATED INSIDE AND OUT UNEXCAVATED A EARTH SECTION A-A ASPHALT A HAND BACKFILL AND IN TAMP 3" LAYERS OPERATING NUT BACKFILL IN 6" LAYERS AND TAMP 2" SQUARE OPEN RIGHT BACKFILL METHOD DEPENDING ON LOCATION NOT TO SCALE 105 C500 VALVE ASSEMBLY BOX STORM DRAIN (SEE SHEET C300) PROPOSED STORM DRAIN (SEE SHEET C300) PROPOSED STORM DRAIN (SEE SHEET C300) DETENTION AREA PROPOSED TRENCH DRAIN PROPOSED 12" BARRIER CURB PROPOSED 12" BARRIER CURB PROPOSED PERMEABLE PAVER AREA 0.5% 0.5% 0.5% 0.5% 28.99 SUB 31.21 28.38 SUB 30.73 RD CONNECTION 2 INV.=5029.34 FG=5031.24 RD BASIN 2 (SOLID LID) INV.=5029.03 FG=5031.23 RD CONNECTION 1 INV.=5028.70 FG=5031.19 RD BASIN 1 (SOLID LID) INV.=5028.61 FG=5031.09 4.63 LF 8" HDPE @ 2.00% 107.87 LF 8" PERF. HDPE @ 0.40% 15.49 LF 8" HDPE @ 2.00% 138.15 LF 8" PERF. HDPE @ 0.40% BASIN A4-1.1 (SOLID LID) INV.=5029.03 FG=5031.25 BASIN A4-1 (SOLID LID) INV.=5028.48 FG=5030.95 28.80 SUB 28.80 SUB 31.16 31.16 28.68 SUB 30.99 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 17 C403 SUBGRADE PLAN A. Reese B. Ruch 1" = 10' LEGEND: NOTES: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 9 PROPOSED SUBGRADE SPOT ELEVATION 33.43 PROPOSED SUBGRADE SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SUBDRAIN PROPOSED HDPE STORM UD PROPOSED FINISHED GRADE SPOT ELEVATION 33.43 (33.43) SUB 1. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 2. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 3. ALL SPOTS SHOWN ARE FISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER AND THE CITY OF FORT COLLINS STORMWATER UTILITY A MINIMUM OF ONE WEEK IN ADVANCE SO AS TO ALLOW FOR FIELD OBSERVATION AND DOCUMENTATION OF THE FOLLOWING SYSTEM ITEMS IN THE SUBGRADE AREA: - SUBGRADE - INSTALLATION OF GEOTEXTILE FABRIC - INSTALLATION OF UNDERDRAIN - PLACEMENT AND COMPACTION OF SUB-BASE MATERIAL - PLACEMENT AND COMPACTION OF BASE MATERIAL - PLACEMENT OF SETTING BED 5. SUBGRADE AREAS ARE TO BE FIELD SURVEYED BY A LICENSED PROFESSIONAL. THE DESIGN ENGINEER MUST CONFIRM THE SUBGRADE ELEVATIONS AND DIMENSIONS PRIOR TO PLACEMENT OF GEOTEXTILE FABRIC, SUB-BASE, OR ANY OTHER MATERIAL. 6. THE CONTRACTOR SHOULD PROVIDE SLACK IN GEOTEXTILE FABRIC TO ENSURE PROPER INSTALLATION AND AGGREGATE PLACEMENT WITHOUT DAMAGE. PROVIDE SUFFICIENT SLACK SO THE FABRIC IS NOT TORN WHEN ROCK IS PLACED. IF TEARS ARE SEEN OR DISCOVERED, REPAIR THEM AS RECOMMENDED BY MANUFACTURER WITH NO LESS THAN 18 INCHES OF OVERLAP ON ALL SIDES OF THE TEAR. 7. THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION, PREVENT SEDIMENT, DEBRIS, AND DIRT FROM ANY SOURCE FROM ENTERING THE VAULT SYSTEM. 8. SEE DETAIL SHEETS FOR ADDITIONAL DESIGN INFORMATION. 9. CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE AND ELECTRIC LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY PROVIDERS TO FACILITATE THE INSTALLATION OF THE PROPOSED STORM DRAIN AND UTILITY SERVICES. PERMEABLE PAVER SECTION W/ UNDERDRAIN NOT TO SCALE 002 C403 \A1;2" \A1;4" \A1;VARIES FILTRAPAVE PAVER (3{}" DEPTH) 30 MIL PVC GEOMEMBRANE WITH CDOT CLASS B GEOTEXTILE SEPARATOR FABRIC ABOVE AND BELOW LINER \A1;SUBGRADE \A1;\pxqr;SUB-BASE COURSE (ASTM NO. 2) BASE COURSE (ASTM NO. 57) BEDDING COURSE (ASTM NO. 8) NOT TO SCALE 001 C403 PERMEABLE PAVER SECTION {NOTES: }PVC GEOMEMBRANE MAY BE OMITTED AND A SINGLE LAYER OF CLASS B GEO-FABRIC MAY BE USED ALONG PERIMETER OF CENTRAL ISLAND. DWG SIZE A SCALE 1:40 SHEET 1 OF 1 DWG NO. 7001-110-042 REV C 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 8 IN - 30 IN TYPICAL INSTALLATION OPTIONS TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 8-10-00 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY AWA NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 8-10-00 CJA DUCTILE IRON DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST T S A L P O L Y N D U C T I L E I R O N S T A L P O L Y N D U C T I L E I R O N DUCTILE IRON DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST WHEN ARE DRAIN BASINS USED? 2808AG _ _ X 2810AG _ _ X 2812AG _ _ X 2815AG _ _ X 2818AG _ _ X 2824AG _ _ X 2830AG _ _ X WHEN ARE INLINE DRAINS USED? 2708AG _ _ X 2710AG _ _ X 2712AG _ _ X 2715AG _ _ X 2718AG _ _ X 2724AG _ _ X 2730AG _ _ X TYPICAL INSTALLATIONS TYPICAL INSTALLATION OF NYLOPLAST DRAIN BASIN AND INLINE DRAIN 1: TO ENTER AN EXISTING LINE USING A TEE & RISER 2: AT THE BEGINNING OF A DRAIN LINE USING AN ELBOW & RISER TEE ELBOW 12" DRAIN BASIN 2 INLET & OUTLET ADAPTERS CAN BE PUT ON ANY ANGLE 1: TO CHANGE ELEVATION 2: TO CHANGE PIPE DIAMETER 3: TO CHANGE PIPE TYPE 4: FOR SHALLOW APPLICATIONS 5: TO CHANGE DIRECTION A° RISER DRAIN BASIN INLINE DRAIN 10" INLINE DRAIN 10" INLINE DRAIN 3 VARIABLE ELEVATION WATERTIGHT ADAPTERS AVAILABLE FOR MOST COMMON PLASTIC PIPING SYSTEMS 8" 6" CORRUGATED HDPE PIPE SMOOTH WALL PVC 1 - STRUCTURES & ADAPTERS AVAILABLE IN SIZES 8" - 30" 2 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°, TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012, 7001-110-013, & 7001-110-014 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS SEE DRAWING NO. 7001-110-065 NOT TO SCALE 004 C403 DISCHARGE BASIN TYPICAL INSTALLATION OPTIONS 8" NOTES: 1 - GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS SEE DRAWING NO. 7001-110-065 4 - PERFORATIONS SHOULD NOT BE ON OR WITHIN 1" OF ADAPTERS. 5 - HOLES SHOULD BE STAGGERED EVERY OTHER ROW, AS SHOWN. 6 - MIN. 90° SEPARATION BETWEEN HOLES (MAX. 4 HOLES PER ROW) 2" MIN 4" Ø PERFORATED PVC EACH WAY SIDE VIEW HOLE SIZE & LOCATION NTS ENLARGED TO SHOW DETAIL 6" THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. TOP 12" TO BE SOLID, WITHOUT PERFORATIONS 6" SOLID BOTTOM NO PERFORATIONS WITHIN 1" OF ADAPTORS BOTTOM 6" TO BE SOLID, WITHOUT PERFORATIONS (BOTTOM CAP TO BE FLUSH WITH SUBGRADE) {NOTE}: CONTRACTOR SHALL USE SQUARE COLLAR IN PERMEABLE PAVER AREAS. COLLAR SHALL BE ORIENTED WITH PAVERS SO AS TO REDUCE IRREGULAR CUTS OR PAVER SHAPES. 003 C403 8" MIN. THICKNESS GUIDELINE 12" MIN WIDTH GUIDELINE VARIES (REFER TO STORM DRAIN PLAN) 3' LONG 4" Ø PERFORATED PVC 3' LONG 4" Ø PERFORATED PVC Ø 0.375" MAX 28.93 28.60 28.88 28.74 28.20 28.28 30.26 30.66 29.64 29.64 31.33 31.33 31.26 29.68 29.36 28.15 28.17 28.07 28.04 28.17 (28.45) (28.40) 28.01 28.01 (28.65) (27.84) (27.60) (28.11) (28.27) (28.25) (28.20) 29.82 31.18 31.33 31.00 30.15 31.07 29.81 31.23 31.33 29.15 28.50 29.64 29.64 31.23 31.23 29.23 FFE=31.33 28.55 0.5% 0.5% 0.5% 0.5% 0.5% 2.0% 1.5% (2.7%) 5.0% 3.6% 5.0% 2.0% 2.0% (2.7%) (1.8%) (1.8%) (4.5%) (2.1%) (28.76) 2.4% 3.1% 5:1 5:1 29.64 28.80 4:1 4:1 6.2% 2.7% 28.21 28.44 28.02 28.86 0.5% 0.4% 2.0% (1.5%) 28.74 2.0% 0.5% X VAULT F.O. FO X X X X X X X X X X X X X X X X X X X X X X X X X X X PROPOSED 2' CONCRETE PAN CAMBRIDGE HOUSE LOFTS BRIDGE-CAMBRIDGE LP 1113 W PLUM ST (33.12) PROPOSED 8" HDPE STORM DRAIN (SEE SHEET C300) PROPOSED 18" LANDSCAPE WALL (RE: LANDSCAPE PLANS) N:126817.51 E:189133.38 FFE=31.33 (30.81) (30.83) (31.92) (31.68) EXISTING WOOD FENCE (32.13) (33.39) (32.68) (32.71) (33.52) (33.98) (32.88) (32.00) (33.78) EXISTING WOOD FENCE 29.22 29.16 30.79 30.09 30.77 29.27 30.83 30.66 30.83 30.83 30.66 30.66 30.83 30.83 30.66 30.66 30.83 30.83 30.66 30.66 30.66 30.66 30.57 30.16 30.66 30.66 29.60 29.68 29.76 30.79 29.96 HP 30.79 29.89 (33.50) 29.36 29.43 29.47 29.54 29.60 29.63 29.83 29.75 30.79 29.67 30.79 30.79 30.79 30.79 30.79 30.79 30.79 30.79 30.79 30.79 0.5% 0.5% 0.5% 0.5% PROPOSED PIPE END w/ CONCRETE COLLAR 0.6% 0.5% 3:1 3:1 3:1 5:1 9:1 3:1 4:1 5:1 5:1 5:1 5.0% 4:1 7:1 30.79 1.0% No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 17 C402 DETAILED GRADING PLAN A. Reese B. Ruch 1" = 10' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 8 LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. THE BOTTOM OF MASONRY SHALL GENERALLY FOLLOW FINISHED GRADES. THERE SHALL BE A MAXIMUM OF 12" EXPOSED CONCRETE BETWEEN THE FINISHED GRADE AND ALL MASONRY. 6. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL CURBS AND GUTTERS AT THE POINTS OF CONNECTION SHOWN ON THE PLANS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 7. ADD 5000-FT TO PROPOSED CONTOURS, SPOT ELEVATIONS, AND FFE LABELS, WHERE TRUNCATED. 8. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED ARCHITECTURAL AND LANDSCAPE ARCHITECTURE DRAWINGS FOR ALL STEPS, RAMPS, LANDSCAPING WALLS, SEATWALLS, RAILINGS, AND PLANTERS. 9. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED STRUCTURAL DRAWINGS FOR ELEVATIONS AND GRADE CONDITIONS ALONG BUILDING PERIMETER. NOTIFY OWNER, ARCHITECT, AND ENGINEER(S) OF ANY DISCREPANCIES PRIOR TO MOBILIZATION. 10. THE FINISHED FLOOR ELEVATIONS SHOWN ARE ABOVE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SWALE FRONT ENTRANCE GRADING DETAIL SCALE: 1" = 10' REAR PAN GRADING DETAIL SCALE: 1" = 10' 30.98 30.77 30.82 31.00 30.88 30.94 FFE=30.36 FFE=30.09 TRASH ENCLOSURE MAINTENANCE ELECTRICAL RISER ROOM 0.5% 0.5% 0.5% 1.5% 0.5% 0.5% 0.6% 1.2% 0.5% 0.5% 0.5% 0.5% 0.5% 1.9% 6.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1.9% 0.5% 2.0% 0.5% 0.5% 0.5% 0.5% 1.7% 0.5% 0.5% 0.4% 31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 31.33 31.00 0.5% 0.5% 6.0% 6.0% 29.49 29.50 32.50 SAND FILTER AREA 29.49 29.37 32.50 29.36 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 17 C401 DETAILED GRADING PLAN A. Reese B. Ruch 1" = 10' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 7 LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. THE BOTTOM OF MASONRY SHALL GENERALLY FOLLOW FINISHED GRADES. THERE SHALL BE A MAXIMUM OF 12" EXPOSED CONCRETE BETWEEN THE FINISHED GRADE AND ALL MASONRY. 6. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL CURBS AND GUTTERS AT THE POINTS OF CONNECTION SHOWN ON THE PLANS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 7. ADD 5000-FT TO PROPOSED CONTOURS, SPOT ELEVATIONS, AND FFE LABELS, WHERE TRUNCATED. 8. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED ARCHITECTURAL AND LANDSCAPE ARCHITECTURE DRAWINGS FOR ALL STEPS, RAMPS, LANDSCAPING WALLS, SEATWALLS, RAILINGS, AND PLANTERS. 9. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED STRUCTURAL DRAWINGS FOR ELEVATIONS AND GRADE CONDITIONS ALONG BUILDING PERIMETER. NOTIFY OWNER, ARCHITECT, AND ENGINEER(S) OF ANY DISCREPANCIES PRIOR TO MOBILIZATION. 10. THE FINISHED FLOOR ELEVATIONS SHOWN ARE ABOVE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SWALE PARKING GARAGE GRADING DETAIL SCALE: 1" = 10' (26.83) (26.50) (30.36) (30.18) (30.28) (33.12) 29.96 HP 29.60 29.16 29.65 29.55 29.43 30.00 30.67 30.67 30.08 28.55 28.16 27.70 28.91 29.03 28.99 29.01 29.04 29.20 29.33 28.27 28.83 28.72 27.51 27.39 27.16 27.05 26.96 (26.41) 27.32 27.39 27.25 27.20 27.13 29.16 29.20 30.18 30.33 28.20 29.09 29.11 29.89 29.13 30.10 30.24 30.52 30.33 30.31 31.28 30.71 31.25 29.23 29.36 28.02 28.00 (28.63) FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 FFE=31.33 30.66 31.33 30.58 30.40 30.28 30.74 31.68 31.33 31.33 30.83 31.28 31.28 31.28 31.28 31.16 31.06 31.33 31.33 31.23 31.23 31.18 31.00 31.04 31.23 29.15 28.55 28.39 28.52 (27.91) (27.73) 30.66 30.66 28.63 28.63 28.40 27.83 (27.77) (27.58) (28.20) (27.82) (28.27) (28.45) (27.84) (27.60) 30.38 29.16 29.27 31.23 28.52 29.04 28.93 28.39 28.75 28.62 31.33 31.33 31.24 31.33 30.26 30.19 30.66 29.82 30.39 29.96 29.75 29.64 30.66 29.89 31.18 28.88 28.74 (27.41) FFE=31.33 30.33 30.66 30.66 30.66 30.83 30.66 30.66 30.83 30.66 30.66 30.83 30.66 30.66 30.79 29.76 30.79 30.16 29.99 30.66 30.66 30.66 30.66 29.66 31.33 29.04 30.79 WEST ELIZABETH STREET (80' ROW) 28.56 28.17 28.15 29.64 28.44 28.28 28.44 TW=5029.20 TW=5029.20 28.07 28.86 TW=5029.20 31.33 31.33 31.10 30.17 30.11 29.36 29.56 30.55 29.21 28.35 29.64 28.48 28.40 31.33 N:126824.52 E:188773.78 N:126817.51 E:189133.38 N:126540.47 E:189130.90 N:126545.83 E:188770.94 30.47 30.41 28.49 28.39 29.02 30.45 30.50 30.56 31.33 31.25 31.27 31.33 31.32 31.26 31.22 N:126781.59 E:188811.77 N:126765.65 E:188869.27 N:126809.04 E:188912.60 N:126805.29 E:189108.19 N:126571.51 E:189087.74 N:126610.13 E:188906.01 N:126610.19 E:188860.84 N:126582.46 E:188803.05 FFE =31.18 31.18 31.08 31.25 31.33 31.32 31.26 31.22 31.24 31.03 30.61 29.60 29.60 29.82 31.33 29.37 30.79 29.63 30.79 29.89 30.79 31.23 28.50 31.23 (28.28) 28.76 28.97 FFE =30.36 FFE =30.09 30.83 30.83 30.66 30.83 30.83 30.66 29.71 29.33 31.30 31.30 28.74 27.71 (27.71) 27.61 (27.61) 27.53 (27.53) 27.41 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.6% 0.7% 3:1 5.2% 7.7% 2.1% 2.7% 2.1% 1.0% 1.0% 3.8% 5.6% 0.5% 0.5% 0.5% 0.5% 6:1 4:1 7:1 5:1 0.5% 2.0% 0.9% 0.5% 1.6% 0.3% 0.9% 0.9% 0.3% 2.1% 2.1% 0.3% 2.0% 1.8% 3.6% 5.0% 2.0% 2.0% 5.0% 2.0% 2.0% 2.0% 2.0% 0.5% 1.8% 2.2% 1.5% 2.9% 0.5% DETENTION AREA RAIN GARDEN VAULT AREA PARKING GARAGE (SEE SHEET C401) SAND FILTER AREA EXISTING SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 6' CONCRETE PAN PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 4' CONCRETE PAN MATCH EXISTING CURB & GUTTER MATCH EXISTING FLOWLINE MATCH EXISTING CURB & GUTTER PROPOSED 31" DRIVE-OVER CURB & GUTTER MATCH EXISTING FLOWLINE MATCH EXISTING FLOWLINE MATCH EXISTING PAVEMENT MATCH EXISTING PAVEMENT TIE TO EXISTING PAN FLOWLINE PROPOSED 4' CONCRETE PAN PROPOSED 2' CONCRETE PAN (SEE SHEET C402 PROPOSED 2' CONCRETE PAN TIE TO EXISTING WALK TIE TO EXISTING WALK TIE TO EXISTING WALK MATCH EXISTING FLOWLINE MATCH EXISTING FLOWLINE EXISTING VERTICAL CURB & GUTTER EXISTING VERTICAL CURB & GUTTER TIE TO EXISTING WALK PROPOSED 18" VERTICAL OUTFALL CURB & GUTTER PROPOSED 18" VERTICAL OUTFALL CURB & GUTTER PROPOSED 18" VERTICAL INFLOW CURB & GUTTER MATCH EXISTING PAVEMENT PROPOSED 18" VERTICAL INFLOW CURB & GUTTER PROPOSED BIO-SWALE (SEE DETAILS) MATCH EXISTING PAVEMENT TIE TO EXISTING WALK MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER PROPOSED 8" PERF. HDPE UNDERDRAIN (SEE SHEET C300) PROPOSED 8" HDPE STORM DRAIN (SEE SHEET C300) PROPOSED 8" HDPE STORM DRAIN (SEE SHEET C300) PROPOSED 18" LANDSCAPE WALL (RE: LANDSCAPE PLANS) PROPOSED 8" HDPE STORM DRAIN (SEE SHEET C300) PROPOSED DETENTION OUTLET w/ ORIFICE PLATE (SEE DETAIL SHEET C502) (3) - 6.5" RISERS w/ 12" TREADS (5) - 6.5" RISERS w/ 12" TREADS (5) - 6.5" RISERS w/ 12" TREADS (4) - 7" RISERS w/ 12" TREADS PROPOSED TRENCH DRAIN (SEE DETAILS) PROPOSED TRENCH DRAIN (SEE DETAILS PROPOSED OUTLET STRUCTURE (SEE DETAIL SHEET C502) (4) - 6" RISERS w/ 12" TREADS PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 8" HDPE ROOF DRAIN CONNECTION (SEE SHEET C300) PROPOSED 8" HDPE ROOF DRAIN CONNECTION (SEE SHEET C300) FRONT ENTRANCE (SEE SHEET C402) SUBGRADE (SEE SHEET C403) 30.67 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 17 C400 GRADING PLAN A. Reese B. Ruch 1" = 20' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 6 LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. THE BOTTOM OF MASONRY SHALL GENERALLY FOLLOW FINISHED GRADES. THERE SHALL BE A MAXIMUM OF 12" EXPOSED CONCRETE BETWEEN THE FINISHED GRADE AND ALL MASONRY. 6. THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL CURBS AND GUTTERS AT THE POINTS OF CONNECTION SHOWN ON THE PLANS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 7. ADD 5000-FT TO PROPOSED CONTOURS, SPOT ELEVATIONS, AND FFE LABELS, WHERE TRUNCATED. 8. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED ARCHITECTURAL AND LANDSCAPE ARCHITECTURE DRAWINGS FOR ALL STEPS, RAMPS, LANDSCAPING WALLS, SEATWALLS, RAILINGS, AND PLANTERS. 9. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED STRUCTURAL DRAWINGS FOR ELEVATIONS AND GRADE CONDITIONS ALONG BUILDING PERIMETER. NOTIFY OWNER, ARCHITECT, AND ENGINEER(S) OF ANY DISCREPANCIES PRIOR TO MOBILIZATION. 10. THE FINISHED FLOOR ELEVATIONS SHOWN ARE ABOVE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SWALE X X X X X X X X t t t X X X X E E E E E E E E E E E E E E E E W W G G G G G E E E E E E E E E E E E E E T T T T T T T T T T E C W W W W W W W W W W W W W W W W L S 23524 FDC EXISTING SIDEWALK CHASE WEST ELIZABETH STREET (80' ROW) PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 6' CONCRETE PAN PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED 4' CONCRETE PAN TIE PAN TO EXISTING FLOWLINE PROPOSED 4' CONCRETE PAN RAIN GARDEN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 18" VERTICAL OUTFALL CURB & GUTTER 20' - 24' - PROPOSED BIO-SWALE (SEE DETAILS) EXISTING 8" CLAY SANITARY SEWER APPROXIMATE LOCATION EXISTING 8" CLAY SANITARY SEWER APPROXIMATE LOCATION EXISTING 8" WATER APPROXIMATE LOCATION EXISTING 14" CSU IRRIGATION EXISTING FH EXISTING SIDEWALK CHASE EXISTING FLOW LINE SECTION LINE EXISTING MANHOLE RIM TO BE ADJUSTED APPROXIMATE LOCATION EXISTING 24" RCP STORM DRAIN PROPOSED 4" WATER SERVICE BASIN A4-2 (SOLID LID) INV.=5028.74 FG=5031.19 OUTLET A4-3 INV. OUT=5029.21 (S) FG=5029.21 BASIN A5 (SOLID LID) INV.=5028.99 FG=5031.22 BASIN A4 (SOLID LID) INV.=5028.44 FG=5030.78 45° BEND A2 INV.=5028.33 FG=5030.45 PIPE END A FG=5028.15 8.31 LF 8" HDPE @ 0.40% 138.16 LF 8" PERF. HDPE @ 0.40% 14.10 LF 8" PERF. HDPE @ 0.40% 64.79 LF 8" HDPE @ 0.40% 118.37 LF 8" HDPE @ 0.40% LOT 3, CAMPUS WEST SHOPPING CENTER COLLINS CAMPUS WEST LLC 1110 W ELIZABETH ST LOT 1, CAMPUS WEST SHOPPING CENTER NCIC LLC 1232 W ELIZABETH ST TOWN SQUARE CONDOMINIUMS LOKAL FORT COLLINS CO LLC 1201 W PLUM ST CAMBRIDGE HOUSE LOFTS BRIDGE-CAMBRIDGE LP 1113 W PLUM ST LOT 1, SOUTH SHIELDS SUBDIVISION 825 S SHIELDS LLC 825 S SHIELDS ST EXISTING TRANSFORMER PROPOSED TRANSFORMER PROPOSED 18" VERTICAL OUTFALL CURB & GUTTER PROPOSED 18" VERTICAL INFLOW CURB & GUTTER PROPOSED 2' CURB CUT N:126824.52 E:188773.78 N:126817.51 E:189133.38 N:126540.47 E:189130.90 N:126545.83 E:188770.94 PROPOSED RELOCATED UTILITIES PROPOSED TRENCH DRAIN PROPOSED RELOCATED UTILITIES PROPOSED RELOCATED UTILITIES 45 ° BEND A1 INV.=5028.18 FG=5029.62 36.82 LF 8" HDPE @ 0.40% 12.79 LF 8" HDPE @ 0.40% PROPOSED TRENCH DRAIN VAULT AREA PROPOSED POND OUTLET w/ WEIR PLATE DETENTION AREA Structure - (37) INV. IN=5025.68 (W) INV. IN=5025.88 (N) INV. OUT=5025.68 (E) FG=5028.13 SSMH INV. IN=5024.87 (W) INV. IN=5025.07 (N) INV. OUT=5024.87 (E) FG=5027.72 COM SSERV 1 INV.=5026.69 FG=5031.23 90° BEND INV.=5026.57 FG=5028.48 COM SSERV 2 INV.=5026.56 FG=5031.23 RES SSERV 1 INV.=5026.20 FG=5029.59 GREASE TRAP 2 INV.=5026.53 FG=5028.46 GREASE TRAP 1 INV.=5026.48 FG=5027.68 4"x4" TEE INV.=5026.44 FG=5027.66 RES SSERV 2 INV.=5025.39 FG=5027.38 8"x4" TEE INV. IN=5025.36 (N) INV. IN=5025.52 (W) INV. OUT=5025.36 (S) FG=5028.21 58.33 LF 8" PVC @ 0.50% 5.92 LF 8" PVC @ 0.50% 45.71 LF 4" PVC @ 2.00% 2.00 LF 4" PVC @ 2.00% 6.02 LF 4" PVC @ 2.00% 6.02 LF 4" PVC @ 2.00% 63.06 LF 8" PVC @ 0.50% 2.00 LF 4" PVC @ 2.00% PROPOSED ±20 LF 12" RCP CULVERT @ 0.50% BASIN A3 (SOLID LID) INV.=5028.38 FG=5030.73 9.92 LF 8" HDPE @ 0.40% BASIN A4-1 (SOLID LID) w/ WEIR STRUCTURE INV.=5028.48 FG=5030.95 138.15 LF 8" PERF. HDPE @ 0.40% 107.87 LF 8" PERF. HDPE @ 0.40% RD CONNECTION 1 INV.=5028.70 FG=5031.19 4.63 LF 8" HDPE @ 2.00% RD BASIN 2 (SOLID LID) INV.=5029.03 FG=5031.23 15.49 LF 8" HDPE @ 2.00% RD CONNECTION 2 INV.=5029.34 FG=5031.24 RD BASIN 1 (SOLID LID) INV.=5028.61 FG=5031.09 20' ACCESS, UTILITY, DRAINAGE, & EMERGENCY ACCESS EASEMENT 20' ACCESS, UTILITY, DRAINAGE, & EMERGENCY ACCESS EASEMENT 15' UTILITY EASEMENT PROPOSED 6' UTILITY EASEMENT 24' ACCESS, UTILITY, DRAINAGE, & EMERGENCY ACCESS EASEMENT UTILITY EASEMENT UTILITY, ACCESS, & DRAINAGE EASEMENT UTILITY, ACCESS, & DRAINAGE EASEMENT DRAINAGE EASEMENT PIPE END A4-1.2 w/ CONCRETE COLLAR FG=5029.22 45.88 LF 8" HDPE @ 0.40% BASIN A4-1.1 (SOLID LID) INV.=5029.03 FG=5031.25 PROPOSED 8" FIRE SERVICE CONNECT TO EXISTING 8" WATER MAIN 8"x4" TAPPING SADDLE w/ 4" GV (N), & TB N:126484.77 E:189101.38 CONNECT TO EXISTING 8" WATER MAIN 8"x8" TAPPING SADDLE w/ 8" GV (N), & TB N:126484.66 E:189110.50 132.93 LF 8" PVC N00°55'40"E 37.34 LF 8" PVC N89°04'20"W 90° BEND w/ TB N:126617.57 E:189112.66 PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT PROPOSED TRANSFORMER PROPOSED 1" WATER SERVICE PROPOSED 1" WATER METER PROPOSED 4" WATER METER POTENTIAL CROSSING CONFLICT (CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION) EXISTING SSMH CONNECT TO EXISTING 8" WATER MAIN 8"x1" TAPPING SADDLE N:126484.87 E:189094.34 POTENTIAL CROSSING CONFLICT (CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION) POTENTIAL CROSSING CONFLICT (CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION) PROPOSED SAWCUT PROPOSED SAWCUT PROPOSED SAWCUT PROPOSED SAWCUT PROPOSED SAWCUT PROPOSED SAWCUT PROPOSED 18" LANDSCAPE WALL PROPOSED GREASE INTERCEPTOR N:126582.46 E:188803.05 N:126781.59 E:188811.77 N:126765.65 E:188869.27 N:126809.04 E:188912.60 N:126805.29 E:189108.19 N:126571.51 E:189087.74 N:126610.13 E:188906.01 N:126610.19 E:188860.84 SAND FILTER AREA No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 17 C300 UTILITY PLAN A. Reese B. Ruch 1"=20' NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF CERTIFICATE OF OCCUPANCY. 9. REFER TO PLUMBING PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS, BOTH THE PLUMBING ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 10. ALL SANITARY SEWER SERVICE CONNECTION INVERTS AND LOCATIONS BASED ON BEST AVAILABLE DATA. CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 11. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 12. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443/C877 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). STORM DRAINS SHOWN ON THIS DRAWING AS POLYVINYL CHLORIDE (PVC) SHALL BE SDR-35 OR APPROVED EQUAL. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 14. CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, FIBER, GAS, AND ELECTRIC LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY PROVIDERS. 15. CONTRACTOR TO COORDINATE FINAL LOCATION OF ALL GAS AND ELECTRIC METERS WITH ARCHITECT AND UTILITY PROVIDERS. 16. THE PLUMBING CONTRACTOR SHALL TERMINATE UTILITY LATERALS 5' OUTSIDE OF BUILDING UNLESS NOTED OTHERWISE. EXACT LOCATIONS (HORIZONTAL AND VERTICAL) OF ALL UTILITY CONNECTIONS INTO THE PROPOSED BUILDING SHALL BE COORDINATED WITH APPROVED MECHANICAL/PLUMBING DRAWINGS. 17. REFER TO APPROVED SITE ELECTRICAL PLANS FOR ALL CONDUITS AND POWER LINE ROUTING FOR SITE LIGHTING. 18. THE LOCATION OF PROPOSED DRY UTILITIES AS SHOWN ON THIS DRAWING ARE SHOWN FOR HORIZONTAL ALIGNMENTS ONLY AND ARE APPROXIMATE. FINAL DESIGNS OF DRY UTILITIES WILL BE PERFORMED BY THE APPROPRIATE UTILITY COMPANY AND/OR ENGINEER. 19. PHONE, INTERNET AND TELEVISION SERVICE TO BE PROVIDED BY CENTURYLINK, COMCAST, OR OTHERS AT THE OWNER'S DISCRETION. APPLICABLE CONDUITS FOR PROSPECTIVE UTILITY COMPANIES SHALL BE PROVIDED. CONTRACTOR SHALL COORDINATE WITH OWNER, UTILITY COMPANIES, UTICOR, AND INFINISYS. 20. ALL CONDUIT PLACED BY THE CONTRACTOR FOR CABLE, PHONE AND INTERNET SHALL BE EQUIPPED WITH PULL TAPE AND LOCATE WIRE PER THE SPECIFICATIONS OF EACH UTILITY COMPANY AND INFINISYS. 21. ELECTRIC SERVICE TO BE PROVIDED BY THE CITY OF FORT COLLINS. THE CITY SHALL INSTALL THE TRANSFORMER AND PRIMARY LINE FROM THE CONNECTION POINT AT THE EXISTING MAIN TO EACH TRANSFORMER. THE COST OF THE PRIMARY LINE, TRANSFORMER, AND INSTALLATION OF THE SECONDARY LINE FROM THE TRANSFORMER TO THE BUILDING SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL ELECTRIC VAULTS ARE TO BE LOCATED IN THE LANDSCAPED PARKWAYS. 22. ELECTRIC TRANSFORMER PAD SIZE IS APPROXIMATE. COORDINATE FINAL LOCATION AND SIZE OF TRANSFORMER WITH APPROVED ELECTRICAL PLANS. 23. GAS SERVICE TO BE PROVIDED BY XCEL ENERGY. XCEL SHALL INSTALL ALL GAS SERVICES AND METERS. THE COST OF ALL THE SERVICE INSTALLATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. 24. CONTRACTOR SHALL COORDINATE OTHER SITE UTILITIES NOT SHOWN ON THESE DRAWINGS; INCLUDING, BUT NOT LIMITED TO, IRRIGATION, PRIVATE SITE ELECTRICAL AND GAS, LOW-VOLTAGE/TELECOMMUNICATIONS, AND POOL SYSTEMS. TYPICAL INSTALLATION DEPTH OF SAID UTILITIES SHALL BE ADJUSTED, AS NECESSARY, TO AVOID ANY POTENTIAL CONFLICTS WITH THE WATER, FIRE, SANITARY SEWER, AND STORM DRAIN LINES SHOWN ON THESE CIVIL DRAWINGS. EXISTING WATER MAIN LEGEND: W G T CTV EXISTING STORM SEWER EXISTING CABLE EXISTING TELEPHONE EXISTING GAS PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED WATER SERVICE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROPERTY BOUNDARY EXISTING LOTLINE W PROPOSED WATER MAIN PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC E PROPOSED FIRE DEPARTMENT CONNECTION FDC TF PROPOSED FIRE SERVICE F EXISTING ELECTRIC E NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner PROPOSED SUBDRAIN UD 5 PROPOSED CABLE CTV PROPOSED FIBRE OPTIC FO PROPOSED GAS G CURB & GUTTER PROPOSED 31" DRIVE-OVER CURB & GUTTER MATCH EXISTING FLOWLINE MATCH EXISTING PAVEMENT MATCH EXISTING PAVEMENT 20' EMERGENCY ACCESS EASEMENT DETENTION AREA PROPOSED 4' CONCRETE PAN PROPOSED 2' CONCRETE PAN LOT 3, CAMPUS WEST SHOPPING CENTER COLLINS CAMPUS WEST LLC 1110 W ELIZABETH ST RAIN GARDEN TOWN SQUARE CONDOMINIUMS LOKAL FORT COLLINS CO LLC 1201 W PLUM ST CAMBRIDGE HOUSE LOFTS BRIDGE-CAMBRIDGE LP 1113 W PLUM ST LOT 1, CAMPUS WEST SHOPPING CENTER NCIC LLC 1232 W ELIZABETH ST PROPOSED 18" VERTICAL INFLOW CURB & GUTTER R25' 20' ACCESS, UTILITY, DRAINAGE, & EMERGENCY ACCESS EASEMENT LOT 1, SOUTH SHIELDS SUBDIVISION 825 S SHIELDS LLC 825 S SHIELDS ST R25' 20' ACCESS, UTILITY, DRAINAGE, & EMERGENCY ACCESS EASEMENT TIE TO EXISTING WALK R15' MATCH EXISTING PAVEMENT TIE TO EXISTING WALK TIE TO EXISTING WALK MATCH EXISTING FLOWLINE MATCH EXISTING FLOWLINE EXISTING VERTICAL CURB & GUTTER EXISTING VERTICAL CURB & GUTTER TIE TO EXISTING WALK SECTION LINE PROPOSED 18" VERTICAL OUTFALL CURB & GUTTER PROPOSED 18" VERTICAL OUTFALL CURB & GUTTER TIE TO EXISTING WALK MATCH EXISTING PAVEMENT PROPOSED 18" VERTICAL INFLOW CURB & GUTTER 20' - 24' - PROPOSED BIO-SWALE PROPOSED EDGE OF PAVEMENT 15' UTILITY EASEMENT 15' UTILITY EASEMENT MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER PROPOSED 18" LANDSCAPE WALL DETENTION VAULT PROPOSED 6' UTILITY EASEMENT PROPOSED 18" CONCRETE WALL PROPOSED 12" BARRIER CURB PROPOSED THICKENED CONCRETE EDGE PROPOSED THICKENED CONCRETE EDGE PROPOSED 2' CURB CUT PROPOSED 2' CURB CUT TRANSITION TO FLUSH CURB R15' R25' 24' ACCESS, UTILITY, DRAINAGE, & EMERGENCY ACCESS EASEMENT UTILITY EASEMENT UTILITY, ACCESS, & DRAINAGE EASEMENT UTILITY, ACCESS, & DRAINAGE EASEMENT PROPOSED SAWCUT PROPOSED SAWCUT DRAINAGE EASEMENT STAIRS STAIRS STAIRS STAIRS STAIRS 21' DRAINAGE EASEMENT PROPOSED SAWCUT PROPOSED SAWCUT N:126781.59 E:188811.77 N:126765.65 E:188869.27 N:126765.11 E:188902.60 N:126582.46 E:188803.05 N:126610.19 E:188860.84 N:126610.13 E:188906.01 N:126809.04 E:188912.60 N:126805.29 E:189108.19 N:126571.51 E:189087.74 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C200 PAVING PLAN HORIZONTAL CONTROL & A. Reese B. Ruch 1"=20' 1. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2. PAVEMENT MARKINGS SHALL BE PER CITY STANDARDS AND PROJECT SPECIFICATION MANUAL. 3. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTER THAT ARE DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED IN LIKE KIND AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. THE LIMITS OF THE REPAIRS WILL BE IDENTIFIED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR PRIOR TO, AND OVER THE COURSE OF, THE PROJECT AND WILL NOT BE SHOWN ON THE PLANS. 5. ALL PUBLIC CONCRETE SIDEWALKS SHALL BE 6" THICK. DRIVEWAY/SIDEWALK CONCRETE SHALL BE 8" (MIN.) THICK. ACTUAL DRIVEWAY CONCRETE THICKNESS SHALL BE BASED ON FINAL PAVEMENT DESIGN. 6. CONTRACTOR SHALL REFER TO, AND COORDINATE WITH, THE APPROVED LANDSCAPE DRAWINGS FOR DETAILED SITE LAYOUT WITHIN THE COURTYARD AND POOL AREAS. IN ADDITION, THE CONTRACTOR SHALL REFER TO, AND COORDINATE WITH, THE APPROVED LANDSCAPE DRAWINGS FOR ALL HARDSCAPE, LANDSCAPE AND SITE FEATURES SUCH AS BIKE RACKS, BENCHES, TRASH RECEPTACLES, LANDSCAPE ROCK AND MULCH, LANDSCAPE WALL CONSTRUCTION DETAILS, TOP OF LANDSCAPE WALL ELEVATIONS, STAIR AND HANDRAIL DETAILS AND SPECIFICATIONS. 7. DUE TO THE NUMBER OF PROPOSED STREET CUTS IN PLUM STREET, THE ENTIRE FULL WIDTH SHALL BE MILLED AND OVERLAID PRIOR TO PROJECT COMPLETION. 8. FOR BUILDING LAYOUTS REFERENCE ARCHITECTURAL PLANS. LAYOUT AND DIMENSION INFORMATION SHOWN REPRESENTS OUTSIDE FACE OF FOUNDATION WALL (NOT STONE VENEER) AND IS SHOWN FOR INFORMATION ONLY. BUILDING POINTS ARE AT CORNERS OF NOMINAL BUILDING FOOTPRINT. CONTRACTOR SHALL CONFIRM ALL BUILDING CORNERS AND STRUCTURAL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO STAKING. 9. CONTRACTOR SHALL REFER TO, AND COORDINATE WITH, THE APPROVED LANDSCAPE DRAWINGS FOR ALL STAIR AND HANDRAIL DETAILS AND SPECIFICATIONS. 10. SEE GEOTECHNICAL REPORT FOR SUBGRADE PREPARATION AND PAVEMENT RECOMMENDATIONS. PROPOSED INFLOW VERTICAL CURB & GUTTER EASEMENTS PUBLIC CONCRETE FLATWORK PROPERTY BOUNDARY PROPOSED LOT LINE PROPOSED EDGE OF PAVEMENT PRIVATE CONCRETE FLATWORK ASPHALT PATCH NORTH LEGEND: NOTES: ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 4 of 17 PROPOSED OUTFALL VERTICAL CURB & GUTTER PAVERS T T T T T T T T T T T T T T T E E E G G G G G G G G / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV T T T T T E E E E E E X X X X X X / / / / / / / / E E E E E E E W X X X SS SS SS SS SS SS SS SS X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X e e g MB t t t i i i C X X X X w w E E E E E E E E E E E E E E E E E E E E E E E T T T T E E E E E E T T T T T T T T T T E E E E E E E E E E G G G G G G G G G G G E E W W W W W W W W W W W T T T T T T T T X C X / / / / / / / / / / / / / / / / W W W W W W W W W W W W W W W W W W SS SS SS SS LOT 3, CAMPUS WEST SHOPPING CENTER COLLINS CAMPUS WEST LLC 1110 W ELIZABETH ST LOT 1, CAMPUS WEST SHOPPING CENTER NCIC LLC 1232 W ELIZABETH ST TOWN SQUARE CONDOMINIUMS LOKAL FORT COLLINS CO LLC 1201 W PLUM ST CAMBRIDGE HOUSE LOFTS BRIDGE-CAMBRIDGE LP 1113 W PLUM ST LOT 1, SOUTH SHIELDS SUBDIVISION 825 S SHIELDS LLC 825 S SHIELDS ST EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING SANITARY SEWER MANHOLE EXISTING ASPHATT TO BE REMOVED EXISTING ASPHATT TO BE REMOVED EXISTING 8" CLAY SANITARY SEWER APPROXIMATE LOCATION EXISTING 8" CLAY SANITARY SEWER APPROXIMATE LOCATION APPROXIMATE LOCATION EXISTING 8" WATER EXISTING 24" RCP STORM EXISTING 6" FIRE SERVICE TO BE REMOVED EXISTING 1 1 2" WATER SERVICE TO BE REMOVED APPROXIMATE LOCATION EXISTING GAS EXISTING 14" CSU IRRIGATION PROPOSED SAWCUT EXISTING BOLLARDS TO BE REMOVED (TYP.) EXISTING UTILITIES TO BE RELOCATED AS NEEDED (TYP.) EXISTING UTILITIES TO BE RELOCATED AS NEEDED (TYP.) EXISTING UTILITIES TO BE RELOCATED AS NEEDED (TYP.) EXISTING LIGHT TO BE REMOVED EXISTING FH EXISTING TREE TO BE REMOVED (TYP.) EXISTING TREE TO REMAIN (TYP.) EXISTING CONCRETE TO BE REMOVED (TYP.) EXISTING CONCRETE TO BE REMOVED (TYP.) EXISTING SIGN TO BE REMOVED EXISTING SIDEWALK CHASE EXISTING SIDEWALK CHASE TO BE REMOVED EXISTING PAN FLOW LINE EXISTING LIGHT TO BE REMOVED EXISTING LIGHT TO BE REMOVED EXISTING LIGHT TO BE REMOVED EXISTING LIGHT TO BE RELOCATED EXISTING LIGHT TO REMAIN EXISTING LIGHT TO REMAIN EXISTING LIGHT TO BE RELOCATED EXISTING SIGN (TYP.) WEST ELIZABETH STREET (80' ROW) SECTION LINE EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING EDGE OF ASPHALT 10' UTILITY EASEMENT TO BE VACATED 12' UTILITY EASEMENT TO BE VACATED DRAINAGE EASEMENT TO BE VACATED UTILITY, PEDESTRIAN & SIDEWALK EASEMENT TO BE VACATED 10' UTILITY EASEMENT TO BE VACATED EXISTING FENCE TO BE REMOVED EXISTING TREES TO REMAIN UTILITY, PEDESTRIAN & SIDEWALK EASEMENT TO BE VACATED N:126540.47 E:189130.90 N:126817.51 E:189133.38 N:126824.52 E:188773.78 N:126545.83 E:188770.94 EXISTING MANHOLE RIM TO BE ADJUSTED EXISTING MANHOLE RIM TO BE ADJUSTED PROPOSED SAWCUT EXISTING CONCRETE PAN FLOWLINE EXISTING 3/4" WATER SERVICE TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / APPROXIMATE LOCATION EXISTING 4" SANITARY SEWER SERVICE TO BE REMOVED APPROXIMATE LOCATION EXISTING 4" SANITARY SEWER SERVICE TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / PROPOSED SAWCUT PROPOSED SAWCUT PROPOSED SAWCUT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING SIGN TO BE REMOVED EXISTING SHEDS TO BE REMOVED EXISTING WOOD ARBOR TO BE REMOVED EXISTING WOOD ARBOR TO BE REMOVED PROPOSED SAWCUT EXISTING ELECTRIC TO BE REMOVED CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH LEGEND: EXISTING STORM SEWER EXISTING VALVE EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 H Y D 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9. NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1-JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10. REFER TO LANDSCAPE AND IRRIGATION PLANS FOR ADDITIONAL TREE PROTECTION MEASURES. TREE PROTECTION NOTES: SUBSURFACE EXPLORATION BY: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7. ADDITIONAL TREES NOT SHOWN ON THESE PLANS MAY EXIST AND MAY REQUIRE REMOVAL. COORDINATION OF WHICH TREES ARE TO REMAIN AND WHICH ARE TO BE REMOVED SHOULD BE COORDINATED WITH THE CITY FORESTER. REFER TO LANDSCAPE PLANS AND TREE MITIGATION PLAN FOR ADDITIONAL INFORMATION. 8. CONTRACTOR SHALL COORDINATE WITH FORT COLLINS UTILITY FIELD OPERATIONS DEPARTMENT AT (970) 221-6700 FOR WATER AND SEWER SERVICE ABANDONMENT. 9. NO DEMOLITION MAY OCCUR ONSITE UNTIL THE APPROPRIATE PERMITS AND APPROVALS HAVE BEEN ISSUED BY THE CITY. THIS INCLUDES, BUT IS NOT LIMITED, TO THE DEMOLITION OF STRUCTURES AND THE REMOVAL OF TREES. 10. NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1-JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. THE SURVEY SHALL BE SENT TO THE CITY ENVIRONMENTAL PLANNER. IF ACTIVE NESTS ARE FOUND, THE CITY WILL COORDINATE WITH RELEVANT STATE AND FEDERAL REPRESENTATIVES TO DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 11. CURB GUTTER, AND SIDEWALK SHALL BE REMOVED TO NE NEAREST JOINT. 12. CONTRACTOR SHALL COORDINATE ALL UTILITY DEMOLITION AND/OR RELOCATION ITEMS WITH THE APPROPRIATE UTILITY PROVIDER PRIOR TO BEGINNING ANY ONSITE DEMOLITION. 13. THE REMOVAL OF UTILITY MAINS AND/OR SERVICES FOR GAS, WATER, AND SANITARY SEWER SHALL BE REMOVED ENTIRELY TO THE ORIGINATING UTILITY MAIN PER CURRENT STANDARDS AND/OR REQUIREMENTS OF THE APPROPRIATE UTILITY COMPANY. 14. DOMESTIC WATER SERVICES FROM THE METER PIT OR CURB STOP WERE NOT LOCATED OR SHOWN ON THIS DRAWING. CONTRACTOR SHALL REMOVE THE ENTIRETY OF THE WATER SERVICES FROM THE ORIGINATING MAIN TO THE EXISTING BUILDING. 15. UTILITY METERS SHOWN ON THIS DRAWING TO BE REMOVED ARE SHOWN PER THE TOPOGRAPHIC SURVEY PERFORMED FOR THE PROJECT AND ONLY INCLUDE THOSE METERS THAT WERE CLEARLY VISIBLE OR ACCESSIBLE AT THE TIME OF THE SURVEY. CONTRACTOR SHALL NOTE THAT ADDITIONAL EXISTING METERS MAY BE PRESENT FROM THOSE SHOWN AND SHALL ACCOUNT FOR AND REMOVE ALL EXISTING METERS. 16. ELECTRIC SERVICES TO EXISTING BUILDINGS TO BE REMOVED ARE SHOWN PER INFORMATION AVAILABLE. CONTRACTOR SHALL NOTE THAT ADDITIONAL UNDERGROUND ELECTRIC SERVICES AND CONDUITS MAY BE PRESENT ON SITE. ALL EXISTING ELECTRIC SERVICE LINES TO BUILDINGS TO BE REMOVED SHALL ALSO BE REMOVED. ALL ELECTRIC REMOVALS OR RELOCATIONS SHALL BE COORDINATED WITH THE CITY OF FORT COLLINS UTILITIES DEPARTMENT PRIOR TO BEGINNING ANY UTILITY DEMOLITIONS. 17. REFER TO AND COORDINATE WITH THE SITE ELECTRICAL PLANS FOR ALL RELOCATED SITE OR STREET LIGHTING. ALL STREET LIGHT RELOCATIONS SHALL BE COORDINATED WITH THE CITY OF FORT COLLINS UTILITIES DEPARTMENT PRIOR TO BEGINNING ANY UTILITY DEMOLITIONS. TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 VAULT ELEC ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 EXISTING CONCRETE TO BE REMOVED T WV W No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 17 C100 & DEMOLITION PLAN EXISTING CONDITIONS A. Reese B. Ruch 1" = 20' NORTHERN ENGINEERING PROJECT NO. 1252-006 DATE: APRIL 2017 PLS GROUP PROJECT NO. 16066.002 DATE: MAY 2017 TERRACON CONSULTANTS, INC. GEOTECHNICAL ENGINEERING REPORT ELIZABETH STREET PROJECT FORT COLLINS, COLORADO TERRACON PROJECT NO. 20165009 DATE: NOVEMBER 18, 2016 REVISED: APRIL 18, 2017 EXISTING TREES (TO BE REMOVED) 3 EXISTING ASPHALT TO BE REMOVED TF sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Final Drainage Report for Union on Elizabeth, dated August 16, 2017 by Northern Engineering shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by th e construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 20-97 At the Southwest corner of West Elizabeth and Constitution Ave. on a concrete traffic signal base. ELEV.=5050.15 City of Fort Collins Benchmark 19-97 At the Southeast corner of West Elizabeth and Shields St., on a concrete traffic signal base. ELEV.=5025.74 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.18' Basis of Bearings The Basis of Bearings is the North line of Lot 4 as bearing South 88°52'58" East. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: N.A. CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. For additional information see separate Stormwater Management Plan / Erosion Control Report for Union on Elizabeth. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage Report for Union on Elizabeth, dated August 16, 2017 by Northern Engineering shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal valve box and "water" lid per City Water Detail 11A. INFILL AND REDEVELOPMENT NOTE Despite everyone's best efforts, it is impossible to fully display subsurface information prior to excavation. This is especially true in areas of infill and redevelopment. Unknown subsurface conditions can have cost and schedule implications. Prior to finalizing contract terms, it is strongly recommended that the Owner and General Contractor have a candid discussion to formulate a strategy for dealing with such circumstances when they arise. The process and procures should be in place prior to excavation. Allowances and contingencies can address the cost implications, but additional measures are required to deal with scheduling and factors impacting sequence of work. The Architect, Engineer(s), and Construction Surveyor should be made aware of the protocol for dealing with such unknown subsurface conditions prior to starting work. C002 GENERAL & CONSTRUCTION NOTES A. Reese B. Ruch NTS No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: AUG. 16, 2017 PROJECT: 1252-005 Sheet UNION ON ELIZABETH These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 08/16/17 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 2 of 17 ELEV.= 5025.74 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.18' Basis of Bearings The Basis of Bearings is the North line of Lot 4 as bearing South 88°52'58" East. Northern Engineering Project No. 1252-006 Date: April 2017 PLS Group Project No. 16066.002 Date: May 2017 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 15, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO (1208 & 1220 WEST ELIZABETH STREET) OWNER/APPLICANT PROJECT TEAM: SITE ENGINEER Northern Engineering Services, Inc. Andy Reese 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SURVEYOR ARCHITECT CONTACT INFORMATION PROJECT TEAM: SHEET INDEX E N G I N E E R I N G N O R T H E RN PDP/FDP UTILITY PLANS FOR City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS----------------- Xcel Energy----------------------------- Pat Kreager (970) 225-7840 ELECTRIC-------- City of Fort Collins Light & Power-- Luke Unruh (970) 416-2724 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink------------------------------- William Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 WASTEWATER--City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 STORMWATER- City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 LANDSCAPE ARCHITECT GEOTECHNICAL ENGINEER PROJECT LOCATION UNION ON ELIZABETH Humphreys & Partners Architects, L.P. Max Reiner 717 17th Street, Suite 650 Denver, CO 80202 (972) 701-9636 Ripley Design, Inc. Stephanie Hansen, PLA, APA 419 Canyon Avenue, Suite 200 Fort Collins, Colorado 80513 (970) 224-5828 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 E N G I N E E R I N G N O R T H E RN Terracon Consultants, Inc. Eric Bernhardt, PE 1901 Sharp Point Drive, Suite C Fort Collins, CO 80525 (970) 484-0359 C001 COVER SHEET A. Reese B. Ruch NTS C001 COVER SHEET Terracon Consultants, Inc. Geotechnical Engineering Report Elizabeth Street Project 1208 and 1220 West Elizabeth Street Fort Collins, Colorado Terracon Project No. 20165099 Date: November 18, 2016 Revised: April 18, 2017 SUBSURFACE EXPLORATION BY: S. SHIELDS ST. W. MULBERRY ST. W. ELIZABETH ST. CSU W. PLUM ST. W. LAUREL ST. CITY PARK AVE. ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ Elizabeth Street CO Owner, LLC 999 South Shady Grove Road, Suite 600 Memphis, TN 38120 (901) 259-2500 MECHANICAL/PLUMBING/ELECTRICAL ENGINEER STRUCTURAL ENGINEER MSP Engineering Group, PLLC 16107 Kensington Dr #278, Sugar Land, TX 77479 (832) 431-4560 MSP Engineering Group, PLLC 16107 Kensington Dr #278, Sugar Land, TX 77479 (832) 431-4560 C002 GENERAL & CONSTRUCTION NOTES C100 EXISTING CONDITIONS & DEMOLITION PLAN C200 HORIZONTAL CONTROL & PAVING PLAN C300 UTILITY PLAN C400 GRADING PLAN 1 C500-C501 C502 UTILITY DETAILS STORMWATER DETAILS C503 SITE DETAILS C600 EROSION CONTROL PLAN C601 EROSION CONTROL DETAILS C700 DRAINAGE EXHIBIT C800 FLOODPLAIN EXHIBIT C403 SUBGRADE PLAN C401-C402 DETAILED GRADING PLAN