HomeMy WebLinkAboutHANSEN (FARM) - ODP - ODP170003 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS12" W 12" W T GAS C T B M TELE X X X M F.O. MM G AS M F.O. 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 2 1 4 ST ST ST ST ST ST ST ST ST ST DETENTION POND 1 ±10.3 AC-FT ±6.2 CFS RELEASE DETENTION POND 2 ±3.6 AC-FT ±1.5 CFS RELEASE DETENTION POND 3 ±1.0 AC-FT ±0.3 CFS RELEASE MMN PRIMARY AND/OR SECONDARY USES ±16.69 ACRES NC PRIMARY AND/OR SECONDARY USES ±6.33 ACRES POUDRE SCHOOL DISTRICT ZONED PUD LEHMAN PROPERTY LARIMER COUNTY TIMBERLINE ROAD (4-LANE ARTERIAL) PROPOSED RIGHT OF WAY DEDICATION TO 4-LANEARTERIAL STANDARDS EXISTING 18" STUB FOR STORM SEWER TIE-IN. MAX RELEASE 12" W 12" W T GAS C T B M TELE M F.O. MM G AS M F.O. 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W POUDRE SCHOOL DISTRICT ZONED PUD LEHMAN PROPERTY LARIMER COUNTY TIMBERLINE ROAD (4-LANE ARTERIAL) PROPOSED RIGHT OF WAY DEDICATION TO 4-LANEARTERIAL STANDARDS CONNECT TO EXISTING 16" WATERLINE CONNECT TO EXISTING 16" WATERLINE CONNECT TO EXISTING 12" WATERLINE STUB CONNECT TO EXISTING 12" SANITARY SEWER MANHOLE MMN PRIMARY AND/OR SECONDARY USES ±16.69 ACRES NC PRIMARY AND/OR SECONDARY USES ±6.33 ACRES EXISTING 16" FCLWD WATERLINE PROPOSED WATERLINE PROPOSED SANITARY SEWER PROPOSED SANITARY SEWER PROPOSED WATERLINE PROPOSED WATERLINE STUB TO ADJACENT PROPERTY NATURAL HABITAT BUFFER ZONE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R MUP 2 LEGEND: ( IN FEET ) 1 inch = ft. 1500Feet 150 150 300 450 W W SS SS NOTES: 1. ALL WATER LINES TIE INTO FORT COLLINS LOVELAND WATER DISTRICT. 2. ALL SANITARY SEWER LINES TIE INTO SOUTH FORT COLLINS SANITATION DISTRICT. 3. ALL STREET ALIGNMENTS AND PROPOSED UTILITIES SHOWN WITH THE MASTER UTILITY PLAN ARE CONCEPTUAL IN NATURE AND ARE SUBJECT TO CHANGE WITH SUBSEQUENT PROJECT DEVELOPMENT PLAN APPLICATIONS. 4. REFER TO HANSEN ODP BY THE BIRDSALL GROUP FOR ADDITIONAL INFORMATION. 5. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. 8 CFS PER TIMBERS DRAINAGE REPORT STORMLINE FOR POND RELEASE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R MDP 1 NOTES: 1. ALL STREET ALIGNMENTS AND PROPOSED DRAINAGE IMPROVEMENTS SHOWN WITH THE MASTER DRAINAGE PLAN ARE CONCEPTUAL IN NATURE AND ARE SUBJECT TO CHANGE WITH SUBSEQUENT PROJECT DEVELOPMENT PLAN APPLICATIONS. 2. REFER TO HANSEN ODP BY THE BIRDSALL GROUP FOR ADDITIONAL INFORMATION. 3. REFER TO HANSEN ODP DRAINAGE LETTER DATED 07/18/2017 FOR MORE INFORMATION REGARDING THE MASTER DRAINAGE PLAN. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. LEGEND: 1 1.45 ac ( IN FEET ) 1 inch = ft. 1500Feet 150 150 300 450