HomeMy WebLinkAboutZIGGI'S COFFEE - PDP - PDP170021 - SUBMITTAL DOCUMENTS - ROUND 2 - REVISIONSAugust 3, 2017 Ziggi’s Coffee 6533 South College Avenue Fort Collins, CO 80525 First Round Meeting Response Letter •• See highlighted comments below stated comment. July 21, 2017 Michael Hunsinger MAH Architectural Group 1385 S. Colorado Blvd. Penthouse Denver, CO 80222 RE: Ziggi's Coffee, PDP170021, Round Number 1 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Ted Shepard, at 970-221-6343 or tshepard@fcgov.com. Comment Summary: Department: Engineering Development Review Contact: Katie Andrews, 970-221-6501, kandrews@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/18/2017 07/18/2017: Please provide the Engineering Department with a copy of the stacking exhibit. ••Stacking exhibit has been provided. Comment Number: 2 Comment Originated: 07/18/2017 07/18/2017: Prior to FDP approval, we will need to confirm that the non-exclusive ROW easement will fulfill our requirement for the standard utility easement. If it does not we will require that the utility easement be dedicated on top of the existing easement. ••Comment is noted. A request to obtain this information has been placed with the project surveyor. Confirmation will be provided or a new easement will be dedicated prior to FDP approval.. 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 Comment Number: 3 Comment Originated: 07/18/2017 07/18/2017: Please note that there is a 2 foot horizontal clearance distance between the public sidewalk and any shrubs/grasses, per LCUASS Figure 16-1. ••Proposed shrubs/grasses are now to be located 2 feet from public sidewalks. Comment Number: 4 Comment Originated: 07/18/2017 07/18/2017: The reception numbers listed on the plans for the ROW and the non-exclusive ROW easement do not appear to be correct. ••The reception numbers have been corrected. Comment Number: 5 Comment Originated: 07/18/2017 07/18/2017: Please fill in General Notes 19 and 41 with project-specific information. ••The aforementioned General Notes have been updated. Comment Number: 6 Comment Originated: 07/18/2017 07/18/2017: When the Traffic and Engineering departments are comfortable with the car stacking, Engineering will be ready for the project to go to hearing. Engineering does not need another formal round of PDP review. Comments 2-5 can be addressed at FDP. ••The aforementioned General Notes have been updated. Department: Environmental Planning Contact: Rebecca Everette, 970-416-2625, reverette@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/12/2017 07/12/2017: LANDSCAPE PLAN: There is significant existing landscaping on the site, which was approved as part of the previous Eckerd Drug project that was approved in the county. Please include an existing conditions plan that documents the number, species and location of existing trees and shrubs. Please note which plants will be protected and which will be removed with this project. Please include a table comparing the number of trees and shrubs to be removed with the number to be planted as part of this project. ••The requested existing conditions plan and the table have been provided. Comment Number: 2 Comment Originated: 07/12/2017 07/12/2017: LANDSCAPE PLAN: The site plan references an area seeded with native grasses. Is this existing or proposed? If proposed, please provide details for the seed mix to be used (species, amounts, etc.). ••The seeded area is existing. Plans have been updated to reflect this. Comment Number: 3 Comment Originated: 07/12/2017 07/12/2017: LANDSCAPE PLAN: It appears that street trees were included in the original landscape plan for Eckerd Drug but were never planted. Street trees will be required along the College Avenue frontage with this project. 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 ••The street trees will now be planted along College Avenue frontage. Comment Number: 4 Comment Originated: 07/12/2017 07/12/2017: LANDSCAPE PLAN: The existing landscaping along College Avenue (mostly junipers) is in poor condition and missing entirely in some sections. These areas need to be brought up to current landscaping standards. Please update the landscape plan to reflect additional planting in these areas. ••The landscape plan has been updated to this requirement. Comment Number: 5 Comment Originated: 07/12/2017 07/12/2017: LANDSCAPE PLAN: Please add a sheet that documents the hydrozones on the site and water budget chart for all landscaping, per LUC section 3.2.1(E)(3). ••A hydrozone plan with water budget chart have been included in the resubmittal. Comment Number: 6 Comment Originated: 07/12/2017 07/12/2017: LANDSCAPE PLAN: Perovskia atriplicifolia (Russian sage) and Frangula alnus (tallhedge buckthorn) are not on the City's approved plant list. Please replace with rabbitbrush, fourwing saltbush, Wood's rose, or other similar species. ••The Russian Sage and Tallhedge Buckthorn have been replaced with plants on the City’s approved plant list. Comment Number: 7 Comment Originated: 07/12/2017 07/12/2017: LANDSCAPE PLAN: The plant list notes 21 Russian sage plants, but I counted 25 on the landscape plan. Please double check all plant counts and update as needed. ••The plant counts have been corrected. Comment Number: 8 Comment Originated: 07/12/2017 07/12/2017: LIGHTING PLAN: To improve clarity, please update note #1 under "Detail Notes" to read: "All existing site light fixtures to remain…" ••The note has been updated. Comment Number: 9 CommentOriginated: 07/12/2017 07/12/2017: LIGHTING PLAN: It is not clear how the Prisma light fixture will be mounted on the building and whether it is full cutoff, fully shielded and down-directional. Please include a detail on the lighting plan that shows how the fixture will be mounted to meet the requirements in LUC section 3.2.4. ••A new light fixture specification has been selected that meets these requirements. Comment Number: 10 Comment Originated: 07/12/2017 07/12/2017: LIGHTING PLAN: Please extend the boundary of the photometrics 20 feet past the northern property line to ensure there are no adverse impacts to that property. ••The photometric boundaries have been extended 20 feet as requested. 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 Department: Forestry Contact: Molly Roche, , mroche@fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 07/19/2017 7/19/2017: Are there existing trees in the parkway? If so, please show them on the landscape plans. If there are no trees in the parkway, please add new trees as needed to meet Land Use Code requirements. Please use the City Street Tree list for approved species. ••The Landscape Plan has been updated to show new trees as requested. Department: Light And Power Contact: Luke Unruh, 9704162724, lunruh@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/19/2017 07/19/2017: Light and Power requires the transformer location be within 10 feet of a drive able surface. In this case I would like to see the proposed transformer location moved to the North West closer to the main entrance, or directly due south. L&P trucks are too big to access the transformer from the drive-thru. ••The transformer has been moved directly due south. Department: PFA Contact: Cal Sheesley, 970-416-2599, csheesley@poudre-fire.org Topic: General Comment Number: 1 Comment Originated: 07/18/2017 07/18/2017: FIRE LANE SIGNS Two additional signs are required and one sign can be relocated. Sign locations are to follow the requirements set forth in LUCASS drawing #1419 (75' spacing). -Two additional signs are required along the south edge of Lot 2. One located near the parking lot light, identifying the Emergency Access Easement (EAE) to the south and one located at the curb between the two side walk curb ramps south west of the proposed building. -The three proposed signs along the east side of the proposed EAE can be reconfigured. two signs can cover the east side of the EAE, spaced 75' apart. The third sign can be relocated to the west side of the EAE, on the small landscape peninsula between the two parking spans. **"FIRE LANE NO PARKING" with directional arrows below is the sign detail the fire department prefers.** 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 ••The fire lane signs have been reconfigured as requested, and the fire lane sign design has been updated to the preferred design. Comment Number: 2 Comment Originated: 07/18/2017 07/18/2017: LANDSCAPE PLAN The proposed Landscape Plan indicates that tree canopy diameters may encroach on the fire lane over time. Four proposed trees appear exist within the proposed EAE. PFA would like to ensure the integrity of the EAE remains as the trees mature and a canopy develops. The EAE shall be maintained to 14' in height. This comment is aimed to preserve the trees and the fire apparatus. ••The trees that may encroach upon the EAE have been relocated. Comment Number: 3 Comment Originated: 07/18/2017 07/18/2017: FIRE LANE For clarity and consistency, the EAE shall be expanded to the full width of the proposed north-south drive lane. Revised plans indicating the fire lane as the full width shall be required. Aligning the proposed EAE with the existing EAE on lot 1 would clean the plans up and prevent confusion moving forward. ••The EAE has been updated to be the full width of the north-south drive lane. Revised linework for a 25-foot wide EAE (full width of the proposed north and south drive lane) has been drafted and supplied to the project surveyor for the preparation of an Easement Dedication Exhibit. Revised linework and labels have added to the affected plan sheets for this submittal. Department: Planning Services Contact: Ted Shepard, 970-221-6343, tshepard@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/19/2017 07/19/2017: Section 3.2.1 of the Land Use Code requires five street trees along College, between the curb and sidewalk, spaced at approximately 40-foot intervals. The selection of species must be made from the approved list per the City Forester. ••The tree species selected is in accordance with the City-approved list. Comment Number: 2 Comment Originated: 07/19/2017 07/19/2017: The Landscape Plan indicates a small turf area, approximately 10¿ x 50¿ located behind the sidewalk near the front of the store. This is a relatively small area and may be difficult to irrigate and mow over the long term. Staff recommends that this area be filled in with shrubs and perennials, featuring a mix of Evergreen and Deciduous plants, with drip irrigation instead. Be sure to select plants of sufficient height in order to contribute to screening the drive-through lane. Staff recommends adding a cluster of Iseli Fastigiate (Columnar Spruce) for excellent vertical form and year-round color. ••The recommended landscaping has been included in the Landscape Plan. Comment Number: 3 Comment Originated: 07/19/2017 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 07/19/2017: The Site Plan indicates 13 parking spaces and a landscape island along the west side of the development. Please show these spaces on the Landscape Plan as well and note that the island needs a shade tree and shrubs to cover. ••The shade tree and shrubs have been added. The Landscape Plan has been updated. Comment Number: 4 Comment Originated: 07/19/2017 07/19/2017: With the southwest elevation being the back of the building, please adjust the Landscape Plan so that a sufficient amount of trees and shrubs are placed in such a way as to screen the electrical meter, electrical panel, gas meter and any other appurtenances that are associated with utilities or other mechanical equipment. This elevation faces north-bound College Avenue traffic and is highly visible. ••The landscaping has been redesigned to mask the equipment at the southwest elevation of the building. Comment Number: 5 Comment Originated: 07/19/2017 07/19/2017: On the Site Plan, Note Number Four, please delete the sentence that begins “In cases where building parapets do not accomplish sufficient screening,…”. This plan needs to ensure, not suggest, that all rooftop mechanical equipment will, in fact, be totally screened by the extent of the parapets. The building is too small to have visible rooftop R.T.U.’s. ••The sentence has been omitted and the note reworded to ensure total screening. Comment Number: 6 Comment Originated: 07/19/2017 07/19/2017: Will there be any future development on this parcel? If so, please indicate on the Site Plan. ••There are no plans for future development at this time. The Site Plan has been updated to reflect this. Comment Number: 7 Comment Originated: 07/19/2017 07/19/2017: Regarding the Lighting Plan, the wall-mount fixture, ALU 2 180 degrees – 120-177 10 x 45 degrees by Performance in Lighting is a combination down-light / up-light fixture. Up-lighting is not allowed per Section 3.2.4.. Please make a new selection that is fully-shielded and down-directional only. ••A new light fixture specification has been selected that meets these requirements. Comment Number: 8 Comment Originated: 07/19/2017 07/19/2017: On the architectural elevations, it would be helpful to designate the dispensing windows. ••The dispensing windows have been designated on the architectural elevations. Comment Number: 9 Comment Originated: 07/19/2017 07/19/2017: Please be aware that the Sign Code has limitations on the extent of window signage. 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 07/13/2017 07/13/2017: Current Erosion Control Materials Submitted do not meet requirements. Please submit; an Erosion Control Plan (based upon returned redlines), an Erosion Control Report (based upon returned comments), and an Escrow / Security Calculation (recalculated based upon plan changes). If you need clarification concerning the erosion control section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com ••Erosion Control Plan, Report, and Escrow / Security Calculation have revised Based on the returned materials.n Erosion Control Plan has been included with the resubmittal. Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General Comment Number: 2 Comment Originated: 07/21/2017 07/21/2017: The plan, as proposed, is not meeting the City's Storm Water LID requirements. The LID mitigation is required to be volume based. This would require a bio-retention basin, or the use of porous pavers. The City suggests a meeting to discuss options. •• Response: The water quality section of the Drainage Letter has been expanded to show that the Approved Drainage Report for Eckerd Drug included volume based water quality mitigation analysis for the areas of the proposed site tributary to the existing pond. The required water quality capture volume has been reduced from the approved to the proposed conditions and the existing pond is adequately sized to treat flows from the tributary areas of the proposed site. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Construction Drawings Comment Number: 10 Comment Originated: 07/19/2017 07/19/2017: Please provide the following information for the Benchmark Statement in the EXACT format shown below. 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX’. •• Benchmark statement has been updated to follow the above format exactly. Comment Number: 11 Comment Originated: 07/20/2017 07/20/2017: There is text that needs to be rotated 180°. See redlines. ••The plans have been updated accordingly.Text has been rotated 180°. Comment Number: 12 Comment Originated: 07/20/2017 07/20/2017: All benchmark statements must match on all sheets. ••The plans have been updated accordingly. Benchmark statement has been updated to follow the above format exactly. Comment Number: 13 Comment Originated: 07/21/2017 07/21/2017: There are line over text issues. See redlines. ••The plans have been updated accordingly.Background masks have been added to all labels. Comment Number: 14 Comment Originated: 07/21/2017 07/21/2017: There is text that needs to be masked. Mask all text in hatched areas. See redlines. ••The plans have been updated accordingly.Background masks have been added to all labels. Topic: Landscape Plans Comment Number: 5 Comment Originated: 07/19/2017 07/19/2017: Please revise the title & sub-title as marked. See redlines. ••The plans have been updated accordingly. Comment Number: 6 Comment Originated: 07/19/2017 07/19/2017: There is text that needs to be masked. Mask all text in hatched areas. See redlines. ••The plans have been updated accordingly. Comment Number: 7 Comment Originated: 07/19/2017 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 07/19/2017: There are text over text issues. See redlines. ••The plans have been updated accordingly. Comment Number: 8 Comment Originated: 07/19/2017 07/19/2017: There are line over text issues. See redlines. ••The plans have been updated accordingly. Topic: Lighting Plan Comment Number: 9 Comment Originated: 07/19/2017 07/19/2017: Please revise the title & sub-title as marked. See redlines. ••The plans have been updated accordingly. Topic: Site Plan Comment Number: 1 Comment Originated: 07/19/2017 07/19/2017: Please revise the title & sub-title as marked. See redlines. ••The plans have been updated accordingly. Comment Number: 2 Comment Originated: 07/19/2017 07/19/2017: Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See redlines. ••The plans have been updated accordingly. Comment Number: 3 Comment Originated: 07/19/2017 07/19/2017: There are line over text issues. See redlines. ••The plans have been updated accordingly. Comment Number: 4 Comment Originated: 07/19/2017 07/19/2017: There is text that needs to be masked. Mask all text in hatched areas. See redlines. ••The plans have been updated accordingly. Department: Traffic Operation Contact: Nicole Hahn, 970-221-6820, nhahn@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/19/2017 07/19/2017: The traffic study indicated that both eastbound and westbound turn lanes are warranted at the Trilby and College intersection with the addition of the traffic from this development. The City of Fort Collins has a funded project for this intersection, and a proportional contribution towards the installation of these turn lanes is required as part of this development. •• City to determine cash in lieu for turn lanes based on impact to the College/ Trilby intersection. Comment Number: 2 Comment Originated: 07/19/2017 07/19/2017: There are some conclusions in the Traffic study that we would like to work with your traffic engineer to better understand. •• Resolved after discussion with City staff. 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609 Comment Number: 3 Comment Originated: 07/19/2017 07/19/2017: We would like to see a queuing analysis to ensure backups will not occur onto arterial roadways. ••A queuing analysis has been provided with the resubmittal. Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/18/2017 07/18/2017: A landscape plan shall contain accurate and identifiable hydrozones, including a water budget chart that shows the total annual water use, which shall not exceed fifteen (15) gallons per square foot over the site. If you have questions contact Eric Olson at eolson@fcgov.com or 970-221-6704. ••A hydrozone plan with water budget chart have been included in the resubmittal. Comment Number: 2 Comment Originated: 07/18/2017 07/18/2017: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Department: Zoning Contact: Marcus Glasgow, 970-416-2338, mglasgow@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/17/2017 07/17/2017: Light levels measured twenty (20) feet beyond the property line of the development site (adjacent to residential uses or public rights-of-way) shall not exceed one-tenth (0.1) foot-candle as a direct result of the on-site lighting. Please update Photometric site plan to show compliance. ••The photometric plan has been updated to reflect these requirements. Comment Number: 2 Comment Originated: 07/17/2017 07/17/2017: Please remove signage from elevations. ••Signage has been removed from the architectural elevations. Comment Number: 3 Comment Originated: 07/17/2017 07/17/2017: Street trees will be required along College Ave. ••The street trees will now be planted along College Avenue frontage. 1385 S. Colorado Blvd, Penthouse Denver, CO 80222 (O)303.778.0608 (F) 303.778.0609