HomeMy WebLinkAboutTHE STANDARD AT FORT COLLINS - FDP - FDP170023 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLAN1
THE STANDARD AT FORT COLLINS
FORT COLLINS, COLORADO
OWNER (SIGNED) Date
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME
WITNESS MY HAND AND OFFICIAL SEAL.
NOTARY PUBLIC ADDRESS
THIS DAY OF
MY COMMISSION EXPIRES:
AS .
(PRINT NAME)
A.D., 20 . BY
THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL
PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE
CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN.
OWNER'S CERTIFICATE
Director Signature
PLANNING CERTIFICATE
APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND
NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO
ON THIS ________ DAY OF ________, 20__.
SITE PLAN NOTES
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE
PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY
CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM
DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET
IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS
OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM
ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT
ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE
PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS
CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING
BUILDING SURFACES.
5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A
PHASING PLAN IS SHOWN WITH THESE PLANS.
6. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN
SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE
WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND
UNNECESSARY DIFFUSION.
7. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE
APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN
CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY.
8. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST
PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM.
9. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED.
10. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE
PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING
SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL
ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE
THAN 1:48 CROSS SLOPE.
11. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND
TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A
PROPERTY OWNERS’ ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR
SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE
AREAS.
12. PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE
COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR
UP
D.S.
D.S.
R.D.
D.S.
D.S. D.S.
D.S.
D.S.
D.S.
D.S.
R.D.
D.S.
PROPERTY LINE
EXISTING ROW LINE
ROW LINE
FUTURE BIKE LANE BY OTHERS
FUTURE PLANT BED BY OTHERS
PROPOSED ROW LINE
PROPERTY LINE
EMERGENCY ACCESS ONLY
PARKING
GARAGE
BUILDING
A
BUILDING
B
LEASING
OFFICE
TRASH/
RECYCLING
TRASH/
RECYCLING
PROSPECT ROAD
LAKE STREET
GARAGE
ENTRY
THE
STADIUM
APARTMENTS
(5-STORY)
THE SLAB
APARTMENTS
(3-STORY)
PLYMOUTH
CONGREGATIONAL
CHURCH
ALLEY
COVERED BIKE PARKING
LOADING AREA
COLORED CONCRETE, TYP. OF HATCH
PERMEABLE PAVERS, TYP. OF HATCH
PERMEABLE PAVERS
DECORATIVE POLE LIGHTS, TYP
EXISTING FLOW LINE
UTILITY EASEMENT
E
E E
E E E E
E
E
WALL ALONG PROPERTY LINE (ENDS AT
SOUTH EDGE OF BUILDING A)
SEATWALL
COVERED BIKE PARKING
REMOVABLE BOLLARDS INDICATES END OF
EMERGENCY ACCESS ONLY
30' X 6' BUS STOP
PEDESTRIAN
CONNECTION
PROPERTY LINE
BENCH, TYP
SIGNAGE TO INDICATE
SERVICE AREA - NO CARS
P
S
RP RP RP RP
RP RP
METAL FENCE
ACCESSIBLE SIDEWALK
WALL, TYP.
WALL, TYP.
GENERAL
RETAIL
1,500 SF
OUTDOOR TABLES
E E E E
P
E
E E
FIRE ACCESS AND
BIKE/PEDESTRIAN
CONNECTION TO
STADIUM
APARTMENTS
SIGNAGE TO INDICATE FIRE ACCESS
E
E
E
26'
EAE
13'-11"
15' UE
26' EAE
15'-7"
13'-11"
5'
16'-2"
19'-2"
12'-11"
17'-9"
21' 25'-10"
36'-6"
20'
EAE
42'-9"
8'
12'
10'-1"
6'-7"
15'
10' SIDEWALK
16'-1"
9' UE
9'-1"
16'-6"
7'-6"
5' 5' 5' 5'
5' 5' 5'
26'-6"
7'-2"
34'-11" 8'-1"
5'
26'
6'-7"
7'-11"
9'-9"
37'-7"
10'-6"
7'-4"
18'-1"
METAL
FENCE
FIRE ACCESS &
BIKE/PED CONNECTION
SIGNAGE TO
INDICATE
FIRE ACCESS WALL, TYP.
SIGNAGE TO INDICATE FIRE ACCESS
30'-9"
STAIRS
38'-4"
36'-8"
S S S
INTERNAL
COURTYARD INTERNAL
COURTYARD
COURTYARD 1
COURTYARD 2 COURTYARD 3
CLUBROOM
(TOP LEVEL)
POOL
AMENITY
AREA
37'-4" 255'-1"
18'-7"
E
S
E
ALLEY
E E
P P P
S
S
S
RAMP
PROPOSED FLOW LINE
WALK CONNECTION
WALK CONNECTION
DWELLING UNIT BREAKDOWN
UNIT TYPE: DWELLING UNITS TOTAL BEDROOMS % (DU)
ONE BEDROOM 42 42 18
TWO BEDROOM 29 58 12
THREE BEDROOM 36 108 15
FOUR BEDROOM 92 368 38
FIVE BEDROOM 40 200 17
TOTAL 239 776 100
GROSS
GROSS AREA 184,157 SF (4.23 AC)
TOTAL DWELLING UNITS 239
GROSS DENSITY 56.50 DU/AC
EXISTING ZONING HMN
NET
NET AREA 175,143 SF (4.0 AC)
TOTAL DWELLING UNITS 239
NET DENSITY 59.75 DU/AC
DENSITY
NET
AREA %
BUILDING COVERAGE 103,317 SF 60%
DRIVES AND PARKING 19,550 SF 11%
OPEN SPACE AND
LANDSCAPE
36,111 SF 21%
HARDSCAPE 13,636 SF 8%
TOTAL NET COVERAGE
175,143 SF
(4.0 AC) 100%
AREA COVERAGE
GROSS
AREA %
BUILDING COVERAGE 103,317 SF 57%
DRIVES AND PARKING 20,079 SF 11%
OPEN SPACE AND
LANDSCAPE
36,611 SF 20%
HARDSCAPE 14,136 SF 7%
RIGHT OF WAY 9,014 SF 5%
DRIVES 554 SF
HARDSCAPE 4,313 SF
LANDSCAPE 4,147 SF
TOTAL GROSS COVERAGE
184,157 SF
(4.23 AC) 100%
FLOOR AREA RATIO
BUILDING AREA 103,317 SF
LOT AREA 175,143 SF
FLOOR AREA RATIO .60
LAND USE CHART
BUILDING HEIGHT
MAXIMUM HEIGHT STORIES
BUILDING A 66' - 7" 5
BUILDING B 69' - 1" 5
BICYCLE PARKING
PROVIDED REQUIRED
ENCLOSED 489 (60%) 466 (60% MIN)
FIXED OUTSIDE 294 (40%) 311 (40%)
TOTAL 783 780
GENERAL RETAIL
AREA 1,500 SF
* REQUIRED BICYCLE SPACES ARE CALCULATED AS FOLLOWED:
776 BEDROOMS X 1 SPACE = 776 SPACES;
60% REQUIRED TO BE ENCLOSED, 40% FIXED.
GENERAL RETAIL: 1 X 4000 S.F. WITH A MINIMUM OF 4 = 4 SPACES;
PROJECT PARKING (LOCATED IN BUILDING B GARAGE)
PROVIDED REQUIRED
RESIDENTIAL PARKING TOTAL 567 582
STANDARD STALLS 552
ELECTRIC CAR SPACES 4
HANDICAP STALLS 11
RETAIL PARKING TOTAL 4 4
STANDARD STALLS 3
HANDICAP STALLS 1
CAR SHARE SPACES 3 3
CAR SHARE CREDIT -15
PROJECT TOTAL 574 574
* REQUIRED PARKING SPACES ARE CALCULATED AS FOLLOWED (PROJECT IS WITHIN TOD OVERLAY ZONE):
776 BEDROOMS (RENTED BY THE BEDROOM) X .75 = 582 SPACES; 15 SPACES ARE MITIGATED FOR BY
PROVIDING 3 CAR SHARE SPACES. 582 SPACES - 15 SPACES = 567 RESIDENTIAL SPACES REQUIRED
1,500 S.F. OF GENERAL RETAIL SPACE (2 SPACES PER 1,000 S.F. REQUIRED) = 4 SPACES.
S = UNIT ENTRY STOOPS
E = ENTRY
RP = RAISED PLANTER
= BENCH
= BIKE RACK (7 SPACES)
= DECORATIVE SITE LIGHTING
UE = UTILITY EASEMENT
EAE = EMERGENCY ACCESS EASEMENT
= PERMEABLE PAVERS
= COLORED CONCRETE
2
NORTH
0 15 30 60
SCALE: 1"=30'-0"
LEGEND
LAND USE BREAKDOWN
1 PROPOSED WALL ELEVATION ADJACENT TO CHURCH
TAN STUCCO
STONE COLUMN
NTS
24'-0"
6'
21'-0"
REVEAL
6.5'
3'
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Brent Layout: 2 Site Plan Printed On: 8/8/2017 5:12 PM File Name: 1 Site Plan.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
LCD ACQUISITIONS, LLC
455 Epps Bridge Parkway
Building 100, Suite 201
Athens, GA 30606
p. 678.835.2674
CIVIL ENGINEER
ARCHITECT
APPLICANT
NORTHERN ENGINEERING
301 N Howes St, Suite 100
Fort Collins, CO 80521
p. 970.221.4158
DWELL DESIGN STUDIO
3655 Brookside Parkway, Suite 150
Alpharetta, GA 30022
p. 770.864.1035
WILLIAMS & ASSOCIATES
2470 Daniells Bridge Rd, Building 100, Suite 161
Athens, GA 30606
p.706.310.0400
OWNER
PROJECT ENGINEER
SITE PLAN
FDP SUBMITTAL
THE STANDARD AT
FORT COLLINS
01 PDP SUPPLEMENT 10.31.16
04 FDP 08.09.17
03 PDP 2 11.30.16
02 PDP 10.19.16
01 PDR 08.10.16
FORT COLLINS, CO
R16-033
ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE
LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED
ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODORCONTROLLED COMPOST BINS, OR
WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF
GRASS.
13. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS
STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO
CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS
STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED
IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
14. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE
OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE
FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO
PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH
ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED
SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AND BE REPLACED OR
REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY.
15. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE
CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY.
UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW
WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED
BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET
OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A
CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING
CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE
USED TO IDENTIFY THE STRUCTURE.
16. FIRE PITS AND GRILLS SHALL HAVE A 10' SEPARATION TO COMBUSTIBLE CONSTRUCTION AND/OR TREES.
THIS DISTANCE IS MEASURED BOTH HORIZONTALLY AND VERTICALLY FROM THE FIRE SOURCE.
17. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE
SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT
BUFFER ZONE.
COVER
SITE PLAN
LANDSCAPE NOTES
LANDSCAPE PLAN
LANDSCAPE SPECIFICATIONS
MITIGATION PLAN
BUILDING A - ELEVATIONS
BUILDING A - ELEVATIONS
BUILDING A - ELEVATIONS
BUILDING A - ELEVATIONS
BUILDING B - ELEVATIONS
BUILDING B - ELEVATIONS
BUILDING B - ELEVATIONS
BUILDING B - ELEVATIONS
PERSPECTIVE
PHOTOMETRIC SITE PLAN
PHOTOMETRIC SITE PLAN SCHEDULES
PHOTOMETRIC SITE PLAN CUT SHEETS
PHOTOMETRIC GARAGE ROOF PLAN
PHOTOMETRIC GARAGE ROOF CUT-SHEET
PHOTOMETRIC GARAGE LVL 1 PLAN
PHOTOMETRIC GARAGE LVL 1 CUT-SHEETS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
SHEET INDEX (PLANNING SET)
VICINITY MAP
SITE
PROSPECT ROAD
SHIELDS STREET
LAKE STREET
PITKIN STREET
WHITCOMB STREET
LEGAL
SCALE: 1' = 500'
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Brent Layout: 1 Cover Sheet Printed On: 8/8/2017 5:12 PM File Name: 1 Site Plan.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
LCD ACQUISITIONS, LLC
455 Epps Bridge Parkway
Building 100, Suite 201
Athens, GA 30606
p. 678.835.2674
CIVIL ENGINEER
ARCHITECT
APPLICANT
NORTHERN ENGINEERING
301 N Howes St, Suite 100
Fort Collins, CO 80521
p. 970.221.4158
DWELL DESIGN STUDIO
3655 Brookside Parkway, Suite 150
Alpharetta, GA 30022
p. 770.864.1035
WILLIAMS & ASSOCIATES
2470 Daniells Bridge Rd, Building 100, Suite 161
Athens, GA 30606
p.706.310.0400
OWNER
PROJECT ENGINEER
COVER SHEET
FDP SUBMITTAL
THE STANDARD AT
FORT COLLINS
01 PDP SUPPLEMENT 10.31.16
04 FDP 08.09.17
03 PDP 2 11.30.16
02 PDP 10.19.16
01 PDR 08.10.16
FORT COLLINS, CO
R16-033