HomeMy WebLinkAboutST. ELIZABETH ANN SETON CATHOLIC CHURCH EXPANSION - ODP - ODP170002 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSGENERAL NOTES 1. CONTRACTOR SHALL VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF ALL UTILITIES, AND SHALL CALL 811 TO HAVE UTILITIES MARKED. 2. ALL EXISTING SITE FEATURES AND UTILITIES SHALL BE PROTECTED IN PLACE UNLESS OTHERWISE NOTED. 3. ANY EXISTING SITE FEATURE OR UTILITY DAMAGED BY CONTRACTOR SHALL BE REPLACED OR REPAIRED AT CONTRACTORS EXPENSE, AND TO A CONDITION EQUAL-TO OR BETTER THEN PRIOR TO CONSTRUCTION ACTIVITIES. 4. ANY DAMAGED CURB, GUTTER AND SIDWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUT TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5. SEE ARCHITECTURAL DRAWINGS FOR ALL PROPOSED OR RELOCATED DRY UTILITY SERVICE CONNECTION POINTS TO BUILDING. 6. CITY OF FORT COLLINS LIGHT & POWER (L&P) SHALL INSTALL ANY PRIMARY LINE FROM CONNECTION POINT TO ELECTRIC VAULT, SECONDARY LINES FROM VAULT TO METER, AND BUILDING METER. CONTRACTOR SHALL COORDINATE WITH FORT COLLINS METER GROUP FOR METER LOCATION. CONTACT CITY OF FORT COLLINS LIGHT & POWER FOR THEIR CURRENT REQUIREMENTS. WATERLINE NOTES 1. WATERLINE CONSTRUCTION IS NOT EXPECTED FOR THE EXPANSION. HOWEVER, IF WATERLINES ARE TO BE CONSTRUCTED, REPAIRED, OR REPLACED, ALL WORK SHALL CONFORM TO THE CURRENT CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS. 2. WATER MAINS, IF NEEDED, SHALL BE PVC (C-900) AS SPECIFIED BY THE CITY OF FORT COLLINS STANDARD PLANS AND SPECIFICATIONS. 3. WATER SERVICES, IF NEEDED, SHALL BE PVC (C-900), AND BE CONSTRUCTED A MINIMUM OF 5-FEET BELOW FINISHED GRADE AND FINISHED FLOOR ELEVATIONS. SANITARY SEWER NOTES 1. ALL SANITARY SEWER PIPE, AND SERVICES, SHALL BE PVC (SDR 35) UNLESS OTHERWISE NOTED ON PLANS. SANITARY SEWER PIPE SHALL BE AS SPECIFIED BY THE SOUTH FORT COLLINS SANITATION DISTRICT. 2. ALL SANITARY SEWER PIPE AND SERVICE FITTINGS SHALL BE PVC (SDR 35) UNLESS OTHERWISE NOTED ON PLANS. 3. A PORTION OF THE EXISTING SANITARY SEWER LINE IS TO BE REPLACED AND RELOCATED BELOW THE CHURCH EXPANSION AS SHOWN ON THE PLANS. THE SANITARY SEWER LINE SHALL BE CONSTRUCTED WITH A CASING PIPE TO ALLOW FOR FUTURE MAINTENANCE. SEE DETAIL THIS SHEET. SEWER LINE JOINTS SHALL BE RESTRAINED, OR WATER PRESSURE PIPE SUBSTITUTED WITH RESTRAINED JOINTS THROUGH CASING. 4. CASING PIPE FOR SANITARY SEWER LINE BELOW BUILDING EXPANSION SHALL BE A MINIMUM OF 22-INCHES IN DIAMETER, AND MAY BE UP TO 24-INCHES IN DIAMETER IF MORE READILY AVAILABLE. STORM SEWER NOTES 1. STORM SEWER PIPE SHALL BE RCP, PVC, OR ADS PIPE AND SHALL HAVE WATER TIGHT JOINTS. 2. ROOF DRAIN COLLECTION PIPES SHALL BE ADS PIPE WITH NYLOPLAST GRATES. 3. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS. 8'' SS 8'' SS 8'' SS 8'' SS PROPOSED EXPANSION EXISTING BUILDING EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE EXISTING LANDSCAPING EXISTING GAS LINE EXISTING FIBER OPTIC EXISTING STORM DRAIN EXISTING WATER SWMM DRAINAGE BASIN BOUNDARY SWMM BASIN DESIGNATION SWMM DESIGN POINT DRAINAGE ARROW NEW & FUTURE IMPERVIOUS IMPROVEMENTS EXISTING IMPERVIOUS AREA (LID TREATED) PROPOSED CONTOURS EXISTING CONTOURS EXISTING BUILDING EXISTING CONCRETE EXISTING LANDSCAPING EXISTING GAS LINE EXISTING FIBER OPTIC EXISTING STORM DRAIN EXISTING WATER EXISTING SANITARY EXISTING TELEPHONE PROPOSED EXPANSION PROPOSED CONCRETE EXISTING ASPHALT 8'' SS 8'' SS 8'' SS 8'' SS 30 70 60 25 20 15 10 35 50 45 THE EXISTING ST. ELIZABETH ANN SETON SITE WAS EVALUATED IN A DRAINAGE AND EROSION CONTROL REPORT, PREPARED BY AYRES ASSOCIATES, AND DATED NOVEMBER 2, 1998. ALL VERTICAL DATA FOUND IN THIS REPORT IS BASED ON NGVD 29 DATUM. 2. THE ST. ELIZABETH ANN SETON SITE WAS EVALUATED FOR ADDITIONAL IMPROVEMENTS IN A DRAINAGE AND EROSION CONTROL REPORT, PREPARED BY AYRES ASSOCIATES, AND DATED JUNE 30, 2003. ALL VERTICAL DATA FOUND IN THIS REPORT IS BASED ON NGVD 29 DATUM. 3. THE TOPOGRAPHY AND ALL ELEVATION INFORMATION SHOWN ON THIS PLAN IS BASED ON THE NAVD 88 DATUM. 4. THE DRAINAGE BASINS SHOWN ON THIS PLAN ARE THE SAME SWMM BASINS IDENTIFIED IN THE TWO FINAL DRAINAGE REPORTS LISTED ABOVE. DATE REVISION DESCRIPTION REVISIONS FILENAME: 0031.0012.00_DRAINAGE 0031.0012.00 1" = 40' JULY 7, 2017 OF DESIGNED: CHECKED: JOB NO.: SCALE: DATE: SHEET NO.: 1" = 40' 0 40 80 scale feet CALL THE UTILITY NOTIFICATION CENTER OF COLORADO 3 DAYS BEFORE YOU DIG 811 OR 1-800-922-1987 www.UNCC.org DAH DAH 5110 GRANITE STREET, UNIT D LOVELAND, COLORADO 80538 (970) 278-0029 CCGCOLORADO CIVIL GROUP, INC. ENGINEERING CONSULTANTS 0" 1" BAR IS ONE INCH ON ORIGINAL DRAWING EXISTING SANITARY EXISTING TELEPHONE DATE REVISION DESCRIPTION REVISIONS FILENAME: 0031.0012.00_UTILITY 0031.0012.00 1" = 40' JULY 7, 2017 OF DESIGNED: CHECKED: JOB NO.: SCALE: DATE: SHEET NO.: 1" = 40' 0 40 80 scale feet CALL THE UTILITY NOTIFICATION CENTER OF COLORADO 3 DAYS BEFORE YOU DIG 811 OR 1-800-922-1987 www.UNCC.org DAH DAH 5110 GRANITE STREET, UNIT D LOVELAND, COLORADO 80538 (970) 278-0029 CCGCOLORADO CIVIL GROUP, INC. ENGINEERING CONSULTANTS 0" 1" BAR IS ONE INCH ON ORIGINAL DRAWING MANUFACTURERS