HomeMy WebLinkAboutST. ELIZABETH ANN SETON CATHOLIC CHURCH EXPANSION - MAJOR AMENDMENT - MJA170001 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSMr. Michael D. DiTullio, Manager
DATUMS
VERTICAL:
BENCHMARK: CITY OF FORT COLLINS "27-94"
ELEVATION = 4927.80 (NAVD88)
HORIZONTAL:
COLORADO STATE PLAN COORDINATES NAD 83 (2011)
DATUM. HORIZONTAL CONTROL BASED UPON TRIMBLE
VRS NETWORK.
Mr. Terry Farrill, P.E., District Engineer
LOT 1, ST. ELIZABETH SETON CATHOLIC CHURCH, P.U.D., FTC; LESS RD ROW PER 99017865
LOCATED IN THE SOUTHWEST QUARTER OF SECTION 6,
TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE SIXTH PRINCIPAL MERIDIAN
CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
VICINITY MAP
APPROX. SCALE: 1"=1,000'
INDEX TO PLANS
SHEET TITLE SHEET NUMBER
COVER 1
UTILITY PLAN 2
GRADING & EROSION CONTROL PLAN 3
DRAINAGE PLAN 4
DATE DESCRIPTION
REVISIONS
0031.0012.00_GENERAL SHEETS
JULY 7, 2017
OF
DATE:
1413 W. 29TH STREET
LOVELAND, COLORADO 80538
(970) 278-0029
CCGCOLORADO
CIVIL
GROUP, INC.
ENGINEERING CONSULTANTS
SHEET:
N/A
SCALE:
0031.0012.00
JOB NO:
DAH
CHECKED:
DAH
DESIGNED:
FILE NAME:
CALL THE UTILITY NOTIFICATION CENTER OF COLORADO
3 DAYS BEFORE YOU DIG
811 OR 1-800-922-1987
www.UNCC.org
Date
Date
All changes, addendums, additions, deletions and modifications to these
drawings must be approved, in writing, by the Fort Collins-Loveland Water
District and the South Fort Collins Sanitation District.
SOUTH FORT COLLINS
SANITATION DISTRICT
COLLEGE AVE.
LEMAY AVE.
SITE
RAILROAD
GENERAL NOTES
1. CONTRACTOR SHALL VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF ALL UTILITIES,
AND SHALL CALL 811 TO HAVE UTILITIES MARKED.
2. ALL EXISTING SITE FEATURES AND UTILITIES SHALL BE PROTECTED IN PLACE UNLESS
OTHERWISE NOTED.
3. ANY EXISTING SITE FEATURE OR UTILITY DAMAGED BY CONTRACTOR SHALL BE REPLACED
OR REPAIRED AT CONTRACTORS EXPENSE, AND TO A CONDITION EQUAL-TO OR BETTER
THEN PRIOR TO CONSTRUCTION ACTIVITIES.
4. ANY DAMAGED CURB, GUTTER AND SIDWALK EXISTING PRIOR TO CONSTRUCTION, AS
WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR
REMOVED DUT TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED
TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE
ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE
FIRST CERTIFICATE OF OCCUPANCY.
5. SEE ARCHITECTURAL DRAWINGS FOR ALL PROPOSED OR RELOCATED DRY UTILITY
SERVICE CONNECTION POINTS TO BUILDING.
6. CITY OF FORT COLLINS LIGHT & POWER (L&P) SHALL INSTALL ANY PRIMARY LINE FROM
CONNECTION POINT TO ELECTRIC VAULT, SECONDARY LINES FROM VAULT TO METER,
AND BUILDING METER. CONTRACTOR SHALL COORDINATE WITH FORT COLLINS METER
GROUP FOR METER LOCATION. CONTACT CITY OF FORT COLLINS LIGHT & POWER FOR
THEIR CURRENT REQUIREMENTS.
WATERLINE NOTES
1. WATERLINE CONSTRUCTION IS NOT EXPECTED FOR THE EXPANSION. HOWEVER, IF
WATERLINES ARE TO BE CONSTRUCTED, REPAIRED, OR REPLACED, ALL WORK SHALL
CONFORM TO THE CURRENT CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS.
2. WATER MAINS, IF NEEDED, SHALL BE PVC (C-900) AS SPECIFIED BY THE CITY OF FORT
COLLINS STANDARD PLANS AND SPECIFICATIONS.
3. WATER SERVICES, IF NEEDED, SHALL BE PVC (C-900), AND BE CONSTRUCTED A MINIMUM
OF 5-FEET BELOW FINISHED GRADE AND FINISHED FLOOR ELEVATIONS.
SANITARY SEWER NOTES
1. ALL SANITARY SEWER PIPE, AND SERVICES, SHALL BE PVC (SDR 35) UNLESS OTHERWISE
NOTED ON PLANS. SANITARY SEWER PIPE SHALL BE AS SPECIFIED BY THE SOUTH FORT
COLLINS SANITATION DISTRICT.
2. ALL SANITARY SEWER PIPE AND SERVICE FITTINGS SHALL BE PVC (SDR 35) UNLESS
OTHERWISE NOTED ON PLANS.
3. A PORTION OF THE EXISTING SANITARY SEWER LINE IS TO BE REPLACED AND RELOCATED
BELOW THE CHURCH EXPANSION AS SHOWN ON THE PLANS. THE SANITARY SEWER LINE
SHALL BE CONSTRUCTED WITH A CASING PIPE TO ALLOW FOR FUTURE MAINTENANCE.
SEE DETAIL THIS SHEET. SEWER LINE JOINTS SHALL BE RESTRAINED, OR WATER
PRESSURE PIPE SUBSTITUTED WITH RESTRAINED JOINTS THROUGH CASING.
4. CASING PIPE FOR SANITARY SEWER LINE BELOW BUILDING EXPANSION SHALL BE A
MINIMUM OF 22-INCHES IN DIAMETER, AND MAY BE UP TO 24-INCHES IN DIAMETER IF MORE
READILY AVAILABLE.
STORM SEWER NOTES
1. STORM SEWER PIPE SHALL BE RCP, PVC, OR ADS PIPE AND SHALL HAVE WATER TIGHT
JOINTS.
2. ROOF DRAIN COLLECTION PIPES SHALL BE ADS PIPE WITH NYLOPLAST GRATES.
3. ALL STORM SEWER SHALL BE INSPECTED BY THE CITY OF FORT COLLINS.
8'' SS 8'' SS 8'' SS
8'' SS
PROPOSED EXPANSION
EXISTING BUILDING
EXISTING ASPHALT
EXISTING CONCRETE
PROPOSED CONCRETE
EXISTING LANDSCAPING
EXISTING GAS LINE
EXISTING FIBER OPTIC
EXISTING STORM DRAIN
EXISTING WATER
8'' SS 8'' SS
8'' SS
8'' SS
1. THIS GRADING AND EROSION CONTROL PLAN CONSIDERS EROSION CONTROL DURING
CONSTRUCTION ACTIVITIES.
2. THE CONTRACTOR SHALL HAVE ON-SITE AT ALL TIMES THE STORMWATER MANAGEMENT
PLAN, AND FOLLOW ALL RECOMMENDATIONS CONTAINED WITHIN.
3. THE CONTRACTOR SHALL RECORD CHANGES TO THE SITE'S STORMWATER MANAGEMENT
PLAN AS CONSTRUCTION ACTIVITIES DICTATE.
4. THE CONTRACTOR SHALL SECURE A STAGING AREA IN COORDINATION WITH THE OWNER,
AND SHALL INCLUDE A SOLID WASTE DISPOSAL AREA, PORT-O-LETS, MATERIAL STORAGE
AND A DEDICATED RE-FUELING AND MAINTENANCE AREA.
5. THE CONTRACTOR CAN CHOOSE BETWEEN SILT FENCE AND SEDIMENT CONTROL LOGS
WHERE INDICATED ON THE PLANS.
6. THE CONTRACTOR SHALL ESTABLISH ONE LOCATION FOR A CONCRETE TRUCK WASHOUT.
7. GRADING CATCH SLOPES SHALL NOT EXCEED 4:1 UNLESS OTHERWISE NOTED ON TEH
PLANS.
8. IF POSSIBLE, AREAS ADJACENT TO THE CHURCH EXPANSION THAT DO NOT RECEIVE
CONCRETE PAVING, THE FINISHED GRADE SHALL FALL ONE FOOT IN THE FIRST 10 FEET
FROM BUILDING OR AT A GRADE OF 10%.
9. PROPOSED EMERGENCY ACCESS ROUTE SHALL BE CONSTRUCTION OF CDOT CLASS D
CONCRETE (4500 PSI), AND SHALL BE A MINIMUM OF 8" THICK OR AS DIRECTED BY A
GEOTECHNICAL ENGINEER.
10. CONTRACTOR SHALL PERFORM A PROOF-ROLL OF THE SUBGRADE BELOW THE
PROPOSED EMERGENCY ACCESS IN THE PRESENCE OF A GEOTECHNICAL ENGINEER.
11. THE LONGITUDINAL SLOPE OF THE EMERGENCY ACCESS DRIVE SHALL NOT EXCEED 10%
IN ANY LOCATION.
12. THE CROSS-SLOPE OF THE EMERGENCY ACCESS DRIVE SHALL BE 2% FALLING AWAY
FROM THE CHURCH AND TOWARD THE EXISTING DETENTION POND.
13. AN EMERGENCY OVERFLOW SECTION IS PROVIDED ALONG THE PROPOSED EMERGENCY
ACCESS DRIVE, IN THE EVENT THE 12-INCH CULVERT IS PLUGGED. THIS OVERFLOW
SECTION IS MORE THAN 12 INCHES BELOW GRADING ADJACENT TO BASEMENT OF
CHURCH.
PROPOSED EXPANSION
EXISTING BUILDING
EXISTING ASPHALT
EXISTING CONCRETE
PROPOSED CONCRETE
EXISTING LANDSCAPING
EXISTING GAS LINE
EXISTING FIBER OPTIC
EXISTING STORM DRAIN
EXISTING WATER
EXISTING SANITARY
EXISTING TELEPHONE
DATE DESCRIPTION
REVISIONS
0031.0012.00_GRADING
JULY 7, 2017
OF
DATE:
1413 W. 29TH STREET
LOVELAND, COLORADO 80538
(970) 278-0029
CCGCOLORADO
CIVIL
GROUP, INC.
ENGINEERING CONSULTANTS
SHEET:
1" = 40'
SWMM DRAINAGE BASIN BOUNDARY
SWMM BASIN DESIGNATION
SWMM DESIGN POINT
DRAINAGE ARROW
NEW & FUTURE IMPERVIOUS IMPROVEMENTS
EXISTING IMPERVIOUS AREA (LID TREATED)
PROPOSED CONTOURS
EXISTING CONTOURS
EXISTING BUILDING EXISTING CONCRETE
EXISTING LANDSCAPING
EXISTING GAS LINE
EXISTING FIBER OPTIC
EXISTING STORM DRAIN
EXISTING WATER
EXISTING SANITARY
EXISTING TELEPHONE
PROPOSED EXPANSION PROPOSED CONCRETE
EXISTING ASPHALT
8'' SS 8'' SS 8'' SS
8'' SS
30
70
60
25
20
15
10
35
50
45
THE EXISTING ST. ELIZABETH ANN SETON SITE WAS EVALUATED IN A DRAINAGE AND
EROSION CONTROL REPORT, PREPARED BY AYRES ASSOCIATES, AND DATED NOVEMBER
2, 1998. ALL VERTICAL DATA FOUND IN THIS REPORT IS BASED ON NGVD 29 DATUM.
2. THE ST. ELIZABETH ANN SETON SITE WAS EVALUATED FOR ADDITIONAL IMPROVEMENTS
IN A DRAINAGE AND EROSION CONTROL REPORT, PREPARED BY AYRES ASSOCIATES,
AND DATED JUNE 30, 2003. ALL VERTICAL DATA FOUND IN THIS REPORT IS BASED ON
NGVD 29 DATUM.
3. THE TOPOGRAPHY AND ALL ELEVATION INFORMATION SHOWN ON THIS PLAN IS BASED
ON THE NAVD 88 DATUM.
4. THE DRAINAGE BASINS SHOWN ON THIS PLAN ARE THE SAME SWMM BASINS IDENTIFIED
IN THE TWO FINAL DRAINAGE REPORTS LISTED ABOVE.
DATE REVISION DESCRIPTION
REVISIONS
FILENAME:
0031.0012.00_DRAINAGE
0031.0012.00
1" = 40'
JULY 7, 2017
OF
DESIGNED:
CHECKED:
JOB NO.:
SCALE:
DATE:
SHEET NO.:
1" = 40'
0 40 80
scale feet
CALL THE UTILITY NOTIFICATION CENTER OF COLORADO
3 DAYS BEFORE YOU DIG
811 OR 1-800-922-1987
www.UNCC.org
DAH
DAH
5110 GRANITE STREET, UNIT D
LOVELAND, COLORADO 80538
(970) 278-0029
CCGCOLORADO
CIVIL
GROUP, INC.
ENGINEERING CONSULTANTS
0" 1" BAR IS ONE INCH ON ORIGINAL DRAWING
Mr. Michael D. DiTullio, Manager
Mr. Terry Farrill, P.E., District Engineer
All changes, addendums, additions, deletions and modifications to these
drawings must be approved, in writing, by the Fort Collins-Loveland Water
District and the South Fort Collins Sanitation District.
SOUTH FORT COLLINS
SANITATION DISTRICT
SCALE:
0031.0012.00
JOB NO:
DAH
CHECKED:
DAH
DESIGNED:
FILE NAME:
0" 1" BAR IS ONE INCH ON ORIGINAL DRAWING
1" = 40'
0 40 80
scale feet
CALL THE UTILITY NOTIFICATION CENTER OF COLORADO
3 DAYS BEFORE YOU DIG
811 OR 1-800-922-1987
www.UNCC.org
Mr. Michael D. DiTullio, Manager
Mr. Terry Farrill, P.E., District Engineer
Date
Date
All changes, addendums, additions, deletions and modifications to these
drawings must be approved, in writing, by the Fort Collins-Loveland Water
District and the South Fort Collins Sanitation District.
SOUTH FORT COLLINS
SANITATION DISTRICT
NOTES:
1. SUB-GRADE BELOW ALL PAVEMENT SECTIONS SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 12" , ADJUSTED IN MOISTURE CONTENT (+ 2%)
AND COMPACTED TO AT LEAST 95% OF THE MATERIAL'S MAXIMUM STANDARD PROCTOR DRY DENSITY AS DETERMINED IN ACCORDANCE
WITH ASTM SPECIFICATION D698. CONTRACTOR SHALL PROOF-ROLL COMPACTED SUB-GRADE IN THE PRESENCE OF A GEOTECHNICAL
ENGINEER OR CITY INSPECTOR.
2. IF SUB-GRADE MATERIAL IS UNSUITABLE (EXHIBITS PUMPING DURING PROOF-ROLL) IT SHALL EITHER BE RECONDITIONED OR REPLACED WITH
SUITABLE ON-SITE MATERIALS. IF CONTRACTOR CHOOSES, STRUCTURAL FILL MAY BE IMPORTED, AT NO EXTRA COST TO OWNER, AND SHALL
BE GRADED SIMILARLY TO CDOT CLASS 5 OR 6 AGGREGATE BASE. CONTRACTOR SHALL PROOF-ROLL ANY RE-WORKED SUB-GRADE PRIOR TO
PLACEMENT OF AGGREGATE BASE COURSE.
3. IF CALLED FOR, AGGREGATE BASE COURSE SHALL BE ADJUSTED IN MOISTURE CONTENT (+ 2%) AND COMPACTED TO ACHIEVE A MINIMUM OF
95% OF THE MATERIAL'S MAXIMUM STANDARD PROCTOR DRY DENSITY AS DETERMINED IN ACCORDANCE WITH ASTM SPECIFICATION D698.
CDOT CLASS D CONCRETE (4500 PSI)
RECONDITIONED SUBGRADE
EXISTING SANITARY
EXISTING TELEPHONE
DATE REVISION DESCRIPTION
REVISIONS
FILENAME:
0031.0012.00_UTILITY
0031.0012.00
1" = 40'
JULY 7, 2017
OF
DESIGNED:
CHECKED:
JOB NO.:
SCALE:
DATE:
SHEET NO.:
1" = 40'
0 40 80
scale feet
CALL THE UTILITY NOTIFICATION CENTER OF COLORADO
3 DAYS BEFORE YOU DIG
811 OR 1-800-922-1987
www.UNCC.org
DAH
DAH
5110 GRANITE STREET, UNIT D
LOVELAND, COLORADO 80538
(970) 278-0029
CCGCOLORADO
CIVIL
GROUP, INC.
ENGINEERING CONSULTANTS
0" 1" BAR IS ONE INCH ON ORIGINAL DRAWING
Mr. Michael D. DiTullio, Manager
Mr. Terry Farrill, P.E., District Engineer
Date
Date
All changes, addendums, additions, deletions and modifications to these
drawings must be approved, in writing, by the Fort Collins-Loveland Water
District and the South Fort Collins Sanitation District.
SOUTH FORT COLLINS
SANITATION DISTRICT
MANUFACTURERS
FOSSIL CREEK TRAIL
TIMBERLINE RD.
ENGINEER
NAME: COLORADO CIVIL GROUP, INC.
CONTACT: DAVID A. HUWA, PE
ADDRESS: 1413 W. 29TH STREET
LOVELAND, COLORADO 80538
PHONE: (970) 278-0029 EXT. 107
FAX: N/A
E-MAIL: dhuwa@ccginc.us
SURVEYOR
NAME: KING SURVEYORS, INC.
CONTACT: LARRY PEPEK
ADDRESS: 650 E. GARDEN DRIVE
WINDSOR, CO 80550
PHONE: (970) 686-5011
E-MAIL: larryp@kingsurveyors.com
ARCHITECT
NAME: EIDOS ARCHITECTS, PC
CONTACT: JON ROSENTHAL
ADDRESS: 5400 GREENWOOD PLAZA BLVD.
GREENWOOD VILLAGE, CO 80111
PHONE: (720) 200-0630
PLANNER/LANDSCAPE ARCHITECT
NAME: TB GROUP
CONTACT: CATHY MATHIS
ADDRESS: 444 MOUNTAIN AVENUE
BERTHOUD, CO 80513
PHONE: (970) 532-5891
S. BOARDWALK DR.