Loading...
HomeMy WebLinkAboutST. ELIZABETH ANN SETON CATHOLIC CHURCH EXPANSION - MAJOR AMENDMENT - MJA170001 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTCOLORADO CIVIL GROUP, INC. DRAINAGE AND EROSION CONTROL REPORT FOR THE ST. ELIZABETH ANN SETON CATHOLIC CHURCH EXPANSION CITY OF FORT COLLINS JULY 7, 2017 COLORADO CIVIL GROUP, INC.  5110 Granite St, Unit D  Loveland, Colorado 80538  970-278-0029 July 7, 2017 Ms. Heather McDowell, PE Water Utilities Engineering City of Fort Collins 281 N College Avenue Fort Collins, CO 80524 Re: St. Elizabeth Ann Seton Catholic Church Expansion Project No. 0031.0012.00 Dear Ms. McDowell, We are pleased to submit this Final Drainage and Erosion Control Report for the St. Elizabeth Ann Seton Catholic Church Expansion project. This report was prepared based on current City of Fort Collins and UDFCD storm drainage criteria. Please let me know if you have any questions or comments. Sincerely, COLORADO CIVIL GROUP, INC. David A. Huwa, PE St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 i Table of Contents 1 Project Summary ...................................................................................................................................................... 1 1.1 Site Location ..................................................................................................................................................... 1 1.2 Project Description ........................................................................................................................................... 2 2 Project Imperviousness ............................................................................................................................................ 2 3 Proposed Drainage Facility Design ........................................................................................................................... 3 3.1 Four‐Step Process ............................................................................................................................................. 3 3.1.1 Step 1: Runoff Reduction .......................................................................................................................... 3 3.1.2 Step 2: Treat and Slowly Release Runoff .................................................................................................. 4 3.1.3 Step 3: Stabilize Drainageways ................................................................................................................. 5 3.1.4 Step 4: Implementation of Source Controls ............................................................................................. 5 3.2 BMP Selection Considerations .......................................................................................................................... 5 3.2.1 Soils ........................................................................................................................................................... 5 3.2.2 Watershed Size ......................................................................................................................................... 6 3.2.3 Base Flows ................................................................................................................................................ 6 3.3 BMP Design ....................................................................................................................................................... 6 3.3.1 Grass Swale ............................................................................................................................................... 6 3.3.2 Rain Garden .............................................................................................................................................. 6 4 Hydrologic Analysis ................................................................................................................................................... 7 5 Stormwater Detention Analysis................................................................................................................................ 7 6 Conclusions ............................................................................................................................................................... 9 Appendix A: Existing Soil Properties ................................................................................................................................. A Appendix B: BMP Sizing and Detention Calculations ...................................................................................................... B Appendix C: Grading and Erosion Control Plan, Drainage Plan ....................................................................................... C Index of Figures and Tables Figure 1‐1: Vicinity Map ................................................................................................................................................... 1 Table 2‐1: UDFCD Percent Impervious Recommendations .............................................................................................. 2 Table 2‐2: New & Future Improvements Imperviousness ............................................................................................... 3 Table 3‐1: LID Treatment .................................................................................................................................................. 7 St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 1 1 Project Summary 1.1 Site Location The St. Elizabeth Ann Seton (SEAS) site, approximately 11.7 acres, is located in the Southwest Quarter of Section 6, Township 7 North, Range 68 West of the 6th Principal Meridian, City of Fort Collins, County of Larimer, Colorado. The site is bounded on the north by Seton Street and on the west by South Lemay Avenue, on the South by Southridge Greens Blvd., and on the east by Southridge Golf Course. A vicinity map is presented in Figure 1-1 below. The project area is generally located at Latitude 40° 30’35.82” and Longitude -105° 03’23.96”. The site is part of the Fossil Creek Drainage Basin and is included as part of the Fossil Creek Drainage Base Master Drainageway Planning Restudy Phase A. Figure 1-1: Vicinity Map ST. ELIZABETH ANN SETON S LEMAY AVE S COLLGE AVE SOUTHRIDGE GREENS BLVD. FOSSILL CREEK PKWY St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 2 1.2 Project Description The SEAS site consists of the existing St. Elizabeth Ann Seton Church, existing parking lots, outdoor sheds, and an existing stormwater drainage system. The existing drainage system includes a detention pond at the southwest corner of the property. The project site is located within Community-Panel Number 08069C1000F. A note on the panel indicates that “No Special Flood Hazard Areas” are present, and so panel is not printed. The FEMA Map Index showing this is found in Appendix A of this report. The proposed improvements include a new worship area, additional concrete walkways, and a concrete paved access for emergency fire equipment. Several storm drainage improvements will also be required due to the additional impervious area. Additionally, this report includes an evaluation of a future impervious improvement, likely an onsite residence for the Church’s Father and additional parking, and will be located in undeveloped areas. The future impervious area will be included in the LID and detention requirements discussed in this report. 2 Project Imperviousness In order to determine the type of stormwater detention and treatment necessary for the project site, the area of the planned improvements was totaled to determine new impervious area. The Urban Drainage and Flood Control District (UDFCD) recommendations for percent impervious were used to determine the overall imperviousness and are presented in Table 2- 1. Table 2-1: UDFCD Percent Impervious Recommendations Land Use of Surface Characteristics Percentage Imperviousness Paved Streets 100% Drives and Walks 90% Roofs 90% Landscaped Areas 2% St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 3 The new and future improvements areas and imperviousness are presented in Table 2-2 below. Table 2-2: New & Future Improvements Imperviousness Area Identification Basin Categories and Areas (SF) Percent Streets Impervious Drives, Walks, & Roofs 100% 90% Concrete Emergency Access 6,774 0 100% Concrete Walkways 0 3,939 90% Church Addition 0 10,981 90% Future Parking 9,341 0 100% Future Residence 0 5,000 90% TOTAL 16,115 19,920 94% This imperviousness has been used to evaluate the existing detention pond, and additional detention required. Additionally, this imperviousness has been used to determine the LID requirements for the project. 3 Proposed Drainage Facility Design This section of the report presents the design of drainage facilities required based on the addition of new and future impervious area as detailed above. The drainage design has been explained as it pertains to the “Four-Step Process for Stormwater Quality Management” as outlined by UDFCD and adopted by the City of Fort Collins. 3.1 Four‐Step Process 3.1.1 Step 1: Runoff Reduction The first step in stormwater quality management is to reduce runoff peaks, volumes, and pollutant loads from urbanizing areas by implementing Low Impact Development (LID) strategies. LID practices include reducing unnecessary impervious areas and routing runoff from impervious surfaces over permeable areas to slow runoff and promote infiltration. St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 4 The SEAS project does include an increase in impervious area with the construction of the proposed improvements detailed above. Runoff generated from the new impervious areas is discharged onto a vegetated buffer prior to entering the existing detention pond, which will promote filtering of the runoff and some infiltration which helps to reduce the peak discharge. The buffer width varies from roughly 50 feet to more than 100 feet. 3.1.2 Step 2: Treat and Slowly Release Runoff After reducing the runoff from a site, the second step in stormwater quality management is to capture and slowly release a Water Quality Capture Volume (WQCV). WQCV facilities may include bioretention, extended detention basins, sand filters, constructed wetland ponds, and retention ponds. The existing detention pond was designed with a WQCV and outlet. These facilities is not expected to be altered with the proposed improvements for the SEAS project. To address the additional impervious areas, and City of Fort Collins drainage requirements, a Rain Garden has been designed and will be constructed to capture a portion of the sites runoff prior to entering the detention pond. Since the proposed improvements span a wide area, it is difficult to capture all of the discharged runoff efficiently, so an ‘area-swap’ is being proposed. The new and future impervious areas total 36,035 square-feet. The existing southeast parking lot includes a total impervious area of approximately 37,600 square-feet, and runoff from the parking lot is conveyed through a small grass swale toward the existing detention pond. A rain garden has been designed to treat approximately 27,026 square-feet, 75% of the new and future impervious area, but will be located to intercept runoff from the existing southeast parking lot. St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 5 The exhibit at right shows new and future impervious areas in green. The existing parking lot, existing grass swale, and proposed rain garden are shown in orange. The rain garden will allow for infiltration and reducing the peak discharge from impervious areas of the site. 3.1.3 Step 3: Stabilize Drainageways Although steps 1 and 2 help to minimize the effects of runoff on downstream drainageways, natural drainageways are often subject to bed and bank erosion due to increases in the frequency, rate, duration, and volume of runoff. Step 3 includes measures to prevent drainageway erosion. There are no proposed drainageways planned for the SEAS site. By implementing steps 1 and 2, the project site does its part to reduce drainageway erosion downstream. Additionally, all disturbed areas will either be paved, re-seeded or landscaped in order to achieve stabilization. And all runoff from the site enters the existing detention pond, so off-site downstream drainageways should be adequately protected. 3.1.4 Step 4: Implementation of Source Controls The final step in stormwater quality management is source control. Site specific needs such as material storage or other site operations require consideration of targeted source control Best Management Practices (BMPs). These BMPs are shown on the Grading & Erosion Control Plan, found in Appendix C of this report. Expected source erosion control BMP’s include straw wattles, inlet and outlet protection, and re-seeding. 3.2 BMP Selection Considerations The following sections discuss the considerations for determining the best BMP or LID solution to implement for the project. 3.2.1 Soils The existing soil condition on the project site must be considered when designing BMPs. Soils with good permeability provide opportunities for infiltration of runoff and are well-suited for infiltration-based BMPs such as rain St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 6 gardens, permeable pavement, and grass swales. The soil on the SEAS site are in Hydrologic Soil Group B and C, which is defined as soils having a moderate to slow infiltration when thoroughly wet. Roughly 75% of the soils are Group B, and for this reason, infiltration based BMPs were considered a good option for the project site. Soil information for the site may be found in Appendix A. 3.2.2 Watershed Size The contributing drainage area is an important consideration for the design of BMPs. The SEAS site is approximately 11.7 acres. An existing detention pond and WQCV facility will continue to be utilized with the new improvements. A rain garden is proposed to filter runoff from a portion of the site prior to entering the existing detention pond. 3.2.3 Base Flows BMPs such as constructed wetlands ponds, retention ponds, and wetland channels require a base flow to prevent the BMPs from becoming dry and unable to support wetland vegetation. No base flow exists for the SEAS project site, so no BMPs that require a base flow were considered for the site. 3.3 BMP Design 3.3.1 Grass Swale Grass swales are vegetated channels with low longitudinal slopes and broad cross-sections that convey flow in a slow and shallow manner to facilitate sedimentation. For the SEAS project, much of the sites runoff is conveyed to small, shallow grass swales located along the west and south boundaries of the site and discharge runoff into the existing detention pond. These existing grass swales will continue to collected and convey runoff to the existing detention pond. 3.3.2 Rain Garden A rain garden utilizes bioretention to reduce the transportation of pollutants to downstream receiving waters through sedimentation, filtering, adsorption, St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 7 evapotranspiration, and biological uptake of constituents. The UDFCD provides guidelines and tools for the design of rain gardens, which have been used for the SEAS project. The sizing calculations` have been included in Appendix B. The City of Fort Collins LID ordinance requires that for 75% of all newly added or modified impervious areas be treated by LID techniques. Table 3-1 shows how the LID requirements have been met for this project. The table shows that a larger area is treated than is required by Ft. Collins ordinance, however, the rain garden has been sized in accordance with the ordinance, so excess flows will overflow into the existing detention pond without treatment. Table 3-1: LID Treatment 75% ON‐SITE TREATMENT BY LID FOR NEW & FUTURE IMPROVEMENTS PROJECT AREA NEW & FUTURE IMPERVIOUS AREAS 36,035 SF REQUIRED MINIMUM AREA TO BE TREATED BY LID (75% OF NEW COMMERCIAL IMPERVIOUS AREA) 27,026 SF EXISTING PARKING LOT AREA 37,600 SF PERCENT OF IMPERVIOUS AREA TREATED BY LID 139 % 4 Hydrologic Analysis Since the new improvements will not drain to existing drainage facilities, except the existing detention pond, a hydrologic analysis of the site has not been performed. If a hydrologic analysis were to be performed, per City of Fort Collins criteria, the Rational Formula Method would be used. The rainfall intensities from the Fort Collins Amendments to the UDFCD manual Table RA-7 were used for the calculation of runoff for a 100-year storm event. 5 Stormwater Detention Analysis The earliest Drainage and Erosion Control Report for the SEAS site found, was prepared by Ayers Associates, Inc., and dated November 2, 1998. Within this report, the 11.7 acre SEAS site was described with an existing detention pond having a 100-year volume of 0.907 acre-foot at an elevation of 4934.55. The detention pond had a release rate of 12.27 cfs with 2.65 feet of freeboard. The vertical datum used in this drainage report was NGVD St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 8 1929, while the current site survey is the NAVD 1988 datum. A vertical datum shift has been performed using the VERTCON website, and shows that the NAVD 1988 datum is 3.01 feet higher than the NGVD 1929 datum. A later site improvement at SEAS required a new Drainage and Erosion Control Report. This report was prepared by Ayers Associates, Inc., and dated June 30, 2003. Within this report, the 11.7 acre SEAS site was again described with an existing detention pond and was modified to include a WQCV outlet structure. The detention pond was modified to detain 1.79 acre-feet at a depth of 5.66 feet, and release runoff at a rate of 12.0 cfs. The 100-year water surface elevation was 4936.41, and the pond had 1.0 feet of freeboard. The vertical datum again used in this drainage report was the NGVD 1929 datum. The 100-year water surface elevation is 4939.42 using the NAVD 1988 datum. Detention Pond Release Rate The SEAS site is located within the Fossil Creek Drainage Basin, a basin that was evaluated in 2004 and determined should have reduced release rates for developed properties. After conversations with the City of Fort Collins Engineering Department, it was determined that the SEAS site will be grand-fathered with regard to release rates, and the existing release rate of 12.0 cfs can be used as the release rate moving forward with new and future improvements. An email from the Engineering Department describing this decision is provided in Appendix B. An orifice calculation was performed for the existing 12-inch outlet pipe. UDFCD Equation 12-19 was used to estimate the discharge capacity of the existing 12-inch outlet pipe. The expected discharge is 8.6 cfs with a ponding depth of 5.66 feet from the 2003 drainage report, and assumes no tailwater influence. This is significantly less than previous drainage reports have indicated, which was 12 cfs. Detention Pond with New & Future Improvements A UDFCD Modified FAA evaluation was performed to determine the required detention volume for the new and future improvements. The 100-year required volume was determined assuming a release rate of 1.02 cfs/acre (12 cfs / 11.7 acres). The required volume (0.13 acre-feet) was added to the existing volume (1.79 acre-feet) described in the previous drainage reports, and a new ponding depth was determined. The existing ponding St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 9 depth was described as 5.66 feet, and the new ponding depth considering the new and future improvements is 6.03 feet, resulting in a new 100-year water surface elevation of . The UDFCD orifice equation was used with a new ponding depth of 6.03 feet. The result shows a discharge of 8.89 cfs, which is still less than the 12 cfs that has been approved by the City of Fort Collins Engineering Department. The freeboard of the existing detention pond will be reduced from 1.0 feet to 0.63 feet, which is considered an acceptable reduction, and does not require raising of the perimeter berm of the detention pond. The calculations are found in Appendix B. 6 Conclusions The final drainage design for the St. Elizabeth Ann Seton Catholic Church Expansion project, as outlined in this Final Drainage and Erosion Control Report, meets or exceeds the drainage criteria set forth by the City of Fort Collins and the UDFCD. The design safely and effectively collects and conveys runoff per the applicable criteria and mimics existing drainage patterns where possible. The Final Drainage Plan map is found in Appendix C. St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 A Appendix A: Existing Soil Properties Drainage Class—Larimer County Area, Colorado (DRAINAGE CLASS) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 1 of 3 4484250 4484290 4484330 4484370 4484410 4484450 4484490 4484250 4484290 4484330 4484370 4484410 4484450 4484490 495030 495070 495110 495150 495190 495230 495270 495310 495350 495390 495030 495070 495110 495150 495190 495230 495270 495310 495350 495390 40° 30' 40'' N 105° 3' 31'' W 40° 30' 40'' N 105° 3' 15'' W 40° 30' 32'' N 105° 3' 31'' W 40° 30' 32'' N 105° 3' 15'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 50 100 200 300 Feet 0 25 50 100 150 Meters Map Scale: 1:1,700 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons Excessively drained Somewhat excessively drained Well drained Moderately well drained Somewhat poorly drained Poorly drained Very poorly drained Subaqueous Not rated or not available Soil Rating Lines Excessively drained Somewhat excessively drained Well drained Moderately well drained Somewhat poorly drained Poorly drained Very poorly drained Subaqueous Not rated or not available Soil Rating Points Excessively drained Somewhat excessively drained Well drained Moderately well drained Somewhat poorly drained Poorly drained Very poorly drained Subaqueous Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Drainage Class Drainage Class— Summary by Map Unit — Larimer County Area, Colorado (CO644) Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 27 Cushman fine sandy loam, 3 to 9 percent slopes Well drained 3.1 26.6% 35 Fort Collins loam, 0 to 3 percent slopes Well drained 0.3 2.1% 55 Kim loam, 5 to 9 percent slopes Well drained 0.4 3.4% 103 Stoneham loam, 5 to 9 percent slopes Well drained 6.1 52.3% 119 Wiley silt loam, 3 to 5 percent slopes Well drained 1.8 15.6% Totals for Area of Interest 11.7 100.0% Description "Drainage class (natural)" refers to the frequency and duration of wet periods under conditions similar to those under which the soil formed. Alterations of the water regime by human activities, either through drainage or irrigation, are not a consideration unless they have significantly changed the morphology of the soil. Seven classes of natural soil drainage are recognized-excessively drained, somewhat excessively drained, well drained, moderately well drained, somewhat poorly drained, poorly drained, and very poorly drained. These classes are defined in the "Soil Survey Manual." Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Tie-break Rule: Higher Drainage Class—Larimer County Area, Colorado DRAINAGE CLASS Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 3 of 3 Hydrologic Soil Group—Larimer County Area, Colorado (HYDROLOGIC SOIL GROUP) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 1 of 4 4484250 4484290 4484330 4484370 4484410 4484450 4484490 4484250 4484290 4484330 4484370 4484410 4484450 4484490 495030 495070 495110 495150 495190 495230 495270 495310 495350 495390 495030 495070 495110 495150 495190 495230 495270 495310 495350 495390 40° 30' 40'' N 105° 3' 31'' W 40° 30' 40'' N 105° 3' 15'' W 40° 30' 32'' N 105° 3' 31'' W 40° 30' 32'' N 105° 3' 15'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 50 100 200 300 Feet 0 25 50 100 150 Meters Map Scale: 1:1,700 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A A/D B B/D C C/D D Not rated or not available Soil Rating Points A A/D B B/D C C/D D Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as Hydrologic Soil Group Hydrologic Soil Group— Summary by Map Unit — Larimer County Area, Colorado (CO644) Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 27 Cushman fine sandy loam, 3 to 9 percent slopes C 3.1 26.6% 35 Fort Collins loam, 0 to 3 percent slopes C 0.3 2.1% 55 Kim loam, 5 to 9 percent slopes B 0.4 3.4% 103 Stoneham loam, 5 to 9 percent slopes B 6.1 52.3% 119 Wiley silt loam, 3 to 5 percent slopes B 1.8 15.6% Totals for Area of Interest 11.7 100.0% Hydrologic Soil Group—Larimer County Area, Colorado HYDROLOGIC SOIL GROUP Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 3 of 4 Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Tie-break Rule: Higher Hydrologic Soil Group—Larimer County Area, Colorado HYDROLOGIC SOIL GROUP Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 4 of 4 Wind Erodibility Group—Larimer County Area, Colorado (WIND ERODIBILITY GROUP) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 1 of 3 4484250 4484290 4484330 4484370 4484410 4484450 4484490 4484250 4484290 4484330 4484370 4484410 4484450 4484490 495030 495070 495110 495150 495190 495230 495270 495310 495350 495390 495030 495070 495110 495150 495190 495230 495270 495310 495350 495390 40° 30' 40'' N 105° 3' 31'' W 40° 30' 40'' N 105° 3' 15'' W 40° 30' 32'' N 105° 3' 31'' W 40° 30' 32'' N 105° 3' 15'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 50 100 200 300 Feet 0 25 50 100 150 Meters Map Scale: 1:1,700 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons 1 2 3 4 4L 5 6 7 8 Not rated or not available Soil Rating Lines 1 2 3 4 4L 5 6 7 8 Not rated or not available Soil Rating Points 1 2 3 4 4L 5 6 7 8 Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Wind Erodibility Group Wind Erodibility Group— Summary by Map Unit — Larimer County Area, Colorado (CO644) Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 27 Cushman fine sandy loam, 3 to 9 percent slopes 3 3.1 26.6% 35 Fort Collins loam, 0 to 3 percent slopes 5 0.3 2.1% 55 Kim loam, 5 to 9 percent slopes 4L 0.4 3.4% 103 Stoneham loam, 5 to 9 percent slopes 6 6.1 52.3% 119 Wiley silt loam, 3 to 5 percent slopes 4L 1.8 15.6% Totals for Area of Interest 11.7 100.0% Description A wind erodibility group (WEG) consists of soils that have similar properties affecting their susceptibility to wind erosion in cultivated areas. The soils assigned to group 1 are the most susceptible to wind erosion, and those assigned to group 8 are the least susceptible. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Tie-break Rule: Lower Wind Erodibility Group—Larimer County Area, Colorado WIND ERODIBILITY GROUP Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 3 of 3 Wind Erodibility Index—Larimer County Area, Colorado (WIND ERODIBILITY INDEX) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 1 of 3 4484250 4484290 4484330 4484370 4484410 4484450 4484490 4484250 4484290 4484330 4484370 4484410 4484450 4484490 495030 495070 495110 495150 495190 495230 495270 495310 495350 495390 495030 495070 495110 495150 495190 495230 495270 495310 495350 495390 40° 30' 40'' N 105° 3' 31'' W 40° 30' 40'' N 105° 3' 15'' W 40° 30' 32'' N 105° 3' 31'' W 40° 30' 32'' N 105° 3' 15'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 50 100 200 300 Feet 0 25 50 100 150 Meters Map Scale: 1:1,700 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons 0 38 48 56 86 134 160 180 220 250 310 Not rated or not available Soil Rating Lines 0 38 48 56 86 134 160 180 220 250 310 Not rated or not available Soil Rating Points 0 38 48 56 86 134 160 180 220 250 310 Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed Wind Erodibility Index Wind Erodibility Index— Summary by Map Unit — Larimer County Area, Colorado (CO644) Map unit symbol Map unit name Rating (tons per acre per year) Acres in AOI Percent of AOI 27 Cushman fine sandy loam, 3 to 9 percent slopes 86 3.1 26.6% 35 Fort Collins loam, 0 to 3 percent slopes 56 0.3 2.1% 55 Kim loam, 5 to 9 percent slopes 86 0.4 3.4% 103 Stoneham loam, 5 to 9 percent slopes 48 6.1 52.3% 119 Wiley silt loam, 3 to 5 percent slopes 86 1.8 15.6% Totals for Area of Interest 11.7 100.0% Description The wind erodibility index is a numerical value indicating the susceptibility of soil to wind erosion, or the tons per acre per year that can be expected to be lost to wind erosion. There is a close correlation between wind erosion and the texture of the surface layer, the size and durability of surface clods, rock fragments, organic matter, and a calcareous reaction. Soil moisture and frozen soil layers also influence wind erosion. Rating Options Units of Measure: tons per acre per year Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Tie-break Rule: Higher Wind Erodibility Index—Larimer County Area, Colorado WIND ERODIBILITY INDEX Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 3 of 3 St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 B Appendix B: BMP Sizing and Detention Calculations 1 David Huwa From: Heather McDowell <hmcdowell@fcgov.com> Sent: Friday, June 23, 2017 2:07 PM To: David Huwa Subject: RE: St. Elizabeth Ann Seton - OLDER DRAINAGE REPORTS Hi David, I talked with others in our group about this one and basically you are grandfathered in the existing release rate from the site (I believe this is the 12.4 cfs or the 13.6 cfs release rate discussed in the 2003 drainage report) but should not be increasing this release rate with the new improvements to your site. Let me know if you want to discuss this any further. Thanks! Heather McDowell, P.E. Water Utilities Engineering City of Fort Collins Office 970.224.6065 Mobile 970.218.9225 hmcdowell@fcgov.com From: David Huwa [mailto:dhuwa@ccginc.us] Sent: Wednesday, June 21, 2017 1:55 PM To: Heather McDowell Cc: David Huwa Subject: St. Elizabeth Ann Seton - OLDER DRAINAGE REPORTS Heather, I’ve provided a DropBox link below so you can download the older drainage reports. Let me know what you think. Thanks. https://www.dropbox.com/sh/n42pl27n81gn45b/AABU8GPNLiGi9ztnwonjtFgka?dl=0 David A. Huwa, P.E. CCG Colorado Civil Group, Inc. 5110 Granite St., Unit D Loveland, CO 80538 www.ccginc.us p: 970.278.0029 c: 970.290.4325 dhuwa@ccginc.us DRAWING DISCLAIMER Colorado Civil Group, Inc. (CCG) transmits this electronic file(s) for reference only. The enclosed file(s) shall not be modified, altered, copied, distributed to third parties, or used on any Project: Basin ID: Design Information (Input): Design Information (Input): Catchment Drainage Imperviousness Ia = 94.00 percent Catchment Drainage Imperviousness I a = 94.00 percent Catchment Drainage Area A = 0.827 acres Catchment Drainage Area A = 0.827 acres Predevelopment NRCS Soil Group Type = B A, B, C, or D Predevelopment NRCS Soil Group Type = B A, B, C, or D Return Period for Detention Control T = 2 years (2, 5, 10, 25, 50, or 100) Return Period for Detention Control T = 100 years (2, 5, 10, 25, 50, or 100) Time of Concentration of Watershed Tc = 5 minutes Time of Concentration of Watershed Tc = 5 minutes Allowable Unit Release Rate q = 0.15 cfs/acre Allowable Unit Release Rate q = 1.02 cfs/acre One-hour Precipitation P1 = 0.83 inches One-hour Precipitation P 1 = 2.75 inches Design Rainfall IDF Formula i = C1* P1 /(C2+Tc )^C3 Design Rainfall IDF Formula i = C1 * P1/(C2 +Tc)^C3 Coefficient One C1 = 28.50 Coefficient One C 1 = 28.50 Coefficient Two C2 = 10 Coefficient Two C 2 =10 Coefficient Three C3 = 0.789 Coefficient Three C 3 = 0.789 Determination of Average Outflow from the Basin (Calculated): Determination of Average Outflow from the Basin (Calculated): Runoff Coefficient C = 0.77 Runoff Coefficient C = 0.86 Inflow Peak Runoff Qp-in = 1.78 cfs Inflow Peak Runoff Qp-in = 6.58 cfs Allowable Peak Outflow Rate Qp-out = 0.13 cfs Allowable Peak Outflow Rate Qp-out = 0.84 cfs Mod. FAA Minor Storage Volume = 1,885 cubic feet Mod. FAA Major Storage Volume = 5,550 cubic feet Mod. FAA Minor Storage Volume = 0.043 acre-ft Mod. FAA Major Storage Volume = 0.127 acre-ft 5 <- Enter Rainfall Duration Incremental Increase Value Here (e.g. 5 for 5-Minutes) Rainfall Rainfall Inflow Adjustment Average Outflow Storage Rainfall Rainfall Inflow Adjustment Average Outflow Storage Duration Intensity Volume Factor Outflow Volume Volume Duration Intensity Volume Factor Outflow Volume Volume minutes inches / hr acre-feet "m" cfs acre-feet acre-feet minutes inches / hr acre-feet "m" cfs acre-feet acre-feet (input) (output) (output) (output) (output) (output) (output) (input) (output) (output) (output) (output) (output) (output) 0 0.00 0.000 0.00 0.00 0.000 0.000 0 0.00 0.000 0.00 0.00 0.000 0.000 5 2.79 0.012 1.00 0.13 0.001 0.011 5 9.25 0.045 1.00 0.84 0.006 0.040 10 2.23 0.020 0.75 0.10 0.001 0.018 10 7.37 0.072 0.75 0.63 0.009 0.064 15 1.87 0.025 0.67 0.08 0.002 0.023 15 6.18 0.091 0.67 0.56 0.012 0.079 20 1.62 0.028 0.63 0.08 0.002 0.026 20 5.35 0.105 0.63 0.53 0.015 0.090 25 1.43 0.031 0.60 0.08 0.003 0.029 25 4.74 0.116 0.60 0.51 0.017 0.099 30 1.29 0.034 0.58 0.07 0.003 0.031 30 4.27 0.125 0.58 0.49 0.020 0.105 35 1.17 0.036 0.57 0.07 0.004 0.033 35 3.89 0.133 0.57 0.48 0.023 0.110 40 1.08 0.038 0.56 0.07 0.004 0.034 40 3.58 0.140 0.56 0.47 0.026 0.114 45 1.00 0.040 0.56 0.07 0.004 0.035 45 3.32 0.146 0.56 0.47 0.029 0.117 50 0.94 0.041 0.55 0.07 0.005 0.036 50 3.10 0.152 0.55 0.46 0.032 0.120 55 0.88 0.042 0.55 0.07 0.005 0.037 55 2.91 0.157 0.55 0.46 0.035 0.122 60 0.83 0.044 0.54 0.07 0.006 0.038 60 2.74 0.161 0.54 0.46 0.038 0.124 65 0.78 0.045 0.54 0.07 0.006 0.039 65 2.60 0.165 0.54 0.45 0.041 0.125 70 0.75 0.046 0.54 0.07 0.007 0.039 70 2.47 0.169 0.54 0.45 0.044 0.126 75 0.71 0.047 0.53 0.07 0.007 0.040 75 2.35 0.173 0.53 0.45 0.046 0.127 80 0.68 0.048 0.53 0.07 0.007 0.040 80 2.25 0.176 0.53 0.45 0.049 0.127 85 0.65 0.049 0.53 0.07 0.008 0.041 85 2.16 0.180 0.53 0.45 0.052 0.127 90 0.63 0.049 0.53 0.07 0.008 0.041 90 2.07 0.183 0.53 0.45 0.055 0.127 95 0.60 0.050 0.53 0.07 0.009 0.041 95 1.99 0.185 0.53 0.44 0.058 0.127 100 0.58 0.051 0.53 0.07 0.009 0.042 100 1.92 0.188 0.53 0.44 0.061 0.127 105 0.56 0.052 0.52 0.07 0.010 0.042 105 1.85 0.191 0.52 0.44 0.064 0.127 110 0.54 0.052 0.52 0.07 0.010 0.042 110 1.79 0.193 0.52 0.44 0.067 0.126 115 0.52 0.053 0.52 0.07 0.011 0.042 115 1.74 0.196 0.52 0.44 0.070 0.126 120 0.51 0.053 0.52 0.07 0.011 0.043 120 1.68 0.198 0.52 0.44 0.073 0.125 125 0.49 0.054 0.52 0.07 0.011 0.043 125 1.63 0.200 0.52 0.44 0.076 0.125 Project: Basin ID: UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.34, Released November 2013 DETENTION VOLUME BY THE MODIFIED FAA METHOD ST. ELIZABETH ANN SETON 0 0.05 0.1 0.15 0.2 0.25 0.3 0 50 100 150 200 250 300 350 Volume (acre-feet) Duration (Minutes) Inflow and Outflow Volumes vs. Rainfall Duration Minor Storm Inflow Volume Minor Storm Outflow Volume Minor Storm Storage Volume Major Storm Inflow Volume Major Storm Outflow Volume Major Storm Storage Volume UD-Detention_v2.34.xls, Modified FAA 7/6/2017, 9:40 PM Project: Basin ID: Design Information (Input): Width of Basin Bottom, W = ft Right Triangle OR… Length of Basin Bottom, L = ft Isosceles Triangle OR… Dam Side-slope (H:V), Zd = ft/ft Rectangle OR… Circle / Ellipse OR… Irregular (Use Overide values in cells G32:G52) MINOR MAJOR Storage Requirement from Sheet 'Modified FAA': 0.04 0.13 acre-ft. Stage-Storage Relationship: Storage Requirement from Sheet 'Hydrograph': acre-ft. Storage Requirement from Sheet 'Full-Spectrum': acre-ft. Labels Water Side Basin Basin Surface Surface Volume Surface Volume Target Volumes for WQCV, Minor, Surface Slope Width at Length at Area at Area at Below Area at Below for WQCV, Minor, & Major Storage Elevation (H:V) Stage Stage Stage Stage Stage Stage Stage & Major Storage Stages ft ft/ft ft ft ft 2 ft 2 User ft 3 acres acre-ft Volumes (input) (input) Below El. (output) (output) (output) Overide (output) (output) (output) (for goal seek) 4933.50 (input) 0 0.000 0.000 4934.00 0.00 0.00 19 5 0.000 0.000 4935.00 0.00 0.00 3,950 1,989 0.091 0.046 4936.00 0.00 0.00 12,274 10,101 0.282 0.232 4937.00 0.00 0.00 17,033 24,755 0.391 0.568 4938.00 0.00 0.00 21,029 43,786 0.483 1.005 4939.00 0.00 0.00 24,710 66,655 0.567 1.530 4940.00 0.00 0.00 28,918 93,469 0.664 2.146 4940.50 0.00 0.00 30,350 108,286 0.697 2.486 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Project: Basin ID: STAGE-STORAGE SIZING FOR DETENTION BASINS 0.00 1000.00 2000.00 3000.00 4000.00 5000.00 6000.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Stage (ft. elev.) Storage (acre-feet) STAGE-STORAGE CURVE FOR THE POND UD-Detention_v2.34.xls, Basin 7/6/2017, 9:41 PM Urban Drainage Orifice Equation (12‐19) Existing Detention Pond Q = CA(2gH)^0.5 Target Orifice Discharge 12 cfs Actual Radius 6 inches Water Depth 5.66 feet C = 0.6 g = 32.2 ft/sec^2 H = 5.16 ft A = 0.785398 ft^2 Q = 8.590312 cfs Good Urban Drainage Orifice Equation (12‐19) Existing Detention Pond with New & Future Improvements Q = CA(2gH)^0.5 Target Orifice Discharge 12 cfs Actual Radius 6 inches Water Depth 6.03 feet C = 0.6 g = 32.2 ft/sec^2 H = 5.53 ft A = 0.785398 ft^2 Q = 8.892966 cfs Good Sheet 1 of 2 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia Ia = 94.0 % (100% if all paved and roofed areas upstream of rain garden) B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 0.940 C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV = 0.35 watershed inches (WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i) D) Contributing Watershed Area (including rain garden area) Area = 27,026 sq ft E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = cu ft Vol = (WQCV / 12) * Area F) For Watersheds Outside of the Denver Region, Depth of d6 = 0.40 in Average Runoff Producing Storm G) For Watersheds Outside of the Denver Region, VWQCV OTHER = 733.3 cu ft Water Quality Capture Volume (WQCV) Design Volume H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER = cu ft (Only if a different WQCV Design Volume is desired) 2. Basin Geometry A) WQCV Depth (12-inch maximum) DWQCV = 12 in B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical) Z = 4.00 ft / ft (Use "0" if rain garden has vertical walls) C) Mimimum Flat Surface Area AMin = 508 sq ft D) Actual Flat Surface Area AActual = 622 sq ft E) Area at Design Depth (Top Surface Area) ATop = 1112 sq ft F) Rain Garden Total Volume VT= 867 cu ft (VT= ((ATop + AActual) / 2) * Depth) 3. Growing Media 4. Underdrain System A) Are underdrains provided? B) Underdrain system orifice diameter for 12 hour drain time i) Distance From Lowest Elevation of the Storage y = ft Volume to the Center of the Orifice ii) Volume to Drain in 12 Hours Vol12 = N/A cu ft iii) Orifice Diameter, 3/8" Minimum DO = N/A in Design Procedure Form: Rain Garden (RG) DAH COLORADO CIVIL GROUP, INC. July 6, 2017 ST. ELIZABETH ANN SETON FT. COLLINS Choose One Choose One 18" Rain Garden Growing Media Other (Explain): YES NO LID CALCS - RAIN GARDEN.xlsm, RG 7/6/2017, 9:44 PM Sheet 2 of 2 Designer: Company: Date: Project: Location: 5. Impermeable Geomembrane Liner and Geotextile Separator Fabric A) Is an impermeable liner provided due to proximity of structures or groundwater contamination? 6. Inlet / Outlet Control A) Inlet Control 7. Vegetation 8. Irrigation A) Will the rain garden be irrigated? Notes: Design Procedure Form: Rain Garden (RG) DAH COLORADO CIVIL GROUP, INC. July 6, 2017 ST. ELIZABETH ANN SETON FT. COLLINS Choose One Choose One Choose One Sheet Flow- No Energy Dissipation Required Concentrated Flow- Energy Dissipation Provided Plantings Seed (Plan for frequent weed control) Sand Grown or Other High Infiltration Sod Choose One YES NO YES NO LID CALCS - RAIN GARDEN.xlsm, RG 7/6/2017, 9:44 PM St. Elizabeth Ann Seton Catholic Church Expansion Final Drainage Report July 2017 C Appendix C: Grading and Erosion Control Plan, Drainage Plan 8'' SS 8'' SS 8'' SS 8'' SS 1. THIS GRADING AND EROSION CONTROL PLAN CONSIDERS EROSION CONTROL DURING CONSTRUCTION ACTIVITIES. 2. THE CONTRACTOR SHALL HAVE ON-SITE AT ALL TIMES THE STORMWATER MANAGEMENT PLAN, AND FOLLOW ALL RECOMMENDATIONS CONTAINED WITHIN. 3. THE CONTRACTOR SHALL RECORD CHANGES TO THE SITE'S STORMWATER MANAGEMENT PLAN AS CONSTRUCTION ACTIVITIES DICTATE. 4. THE CONTRACTOR SHALL SECURE A STAGING AREA IN COORDINATION WITH THE OWNER, AND SHALL INCLUDE A SOLID WASTE DISPOSAL AREA, PORT-O-LETS, MATERIAL STORAGE AND A DEDICATED RE-FUELING AND MAINTENANCE AREA. 5. THE CONTRACTOR CAN CHOOSE BETWEEN SILT FENCE AND SEDIMENT CONTROL LOGS WHERE INDICATED ON THE PLANS. 6. THE CONTRACTOR SHALL ESTABLISH ONE LOCATION FOR A CONCRETE TRUCK WASHOUT. 7. GRADING CATCH SLOPES SHALL NOT EXCEED 4:1 UNLESS OTHERWISE NOTED ON TEH PLANS. 8. IF POSSIBLE, AREAS ADJACENT TO THE CHURCH EXPANSION THAT DO NOT RECEIVE CONCRETE PAVING, THE FINISHED GRADE SHALL FALL ONE FOOT IN THE FIRST 10 FEET FROM BUILDING OR AT A GRADE OF 10%. 9. PROPOSED EMERGENCY ACCESS ROUTE SHALL BE CONSTRUCTION OF CDOT CLASS D CONCRETE (4500 PSI), AND SHALL BE A MINIMUM OF 8" THICK OR AS DIRECTED BY A GEOTECHNICAL ENGINEER. 10. CONTRACTOR SHALL PERFORM A PROOF-ROLL OF THE SUBGRADE BELOW THE PROPOSED EMERGENCY ACCESS IN THE PRESENCE OF A GEOTECHNICAL ENGINEER. 11. THE LONGITUDINAL SLOPE OF THE EMERGENCY ACCESS DRIVE SHALL NOT EXCEED 10% IN ANY LOCATION. 12. THE CROSS-SLOPE OF THE EMERGENCY ACCESS DRIVE SHALL BE 2% FALLING AWAY FROM THE CHURCH AND TOWARD THE EXISTING DETENTION POND. 13. AN EMERGENCY OVERFLOW SECTION IS PROVIDED ALONG THE PROPOSED EMERGENCY ACCESS DRIVE, IN THE EVENT THE 12-INCH CULVERT IS PLUGGED. THIS OVERFLOW SECTION IS MORE THAN 12 INCHES BELOW GRADING ADJACENT TO BASEMENT OF CHURCH. PROPOSED EXPANSION EXISTING BUILDING EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE EXISTING LANDSCAPING EXISTING GAS LINE EXISTING FIBER OPTIC EXISTING STORM DRAIN EXISTING WATER EXISTING SANITARY EXISTING TELEPHONE DATE DESCRIPTION REVISIONS 0031.0012.00_GRADING JULY 7, 2017 OF DATE: 1413 W. 29TH STREET LOVELAND, COLORADO 80538 (970) 278-0029 CCGCOLORADO CIVIL GROUP, INC. ENGINEERING CONSULTANTS SHEET: 1" = 40' SWMM DRAINAGE BASIN BOUNDARY SWMM BASIN DESIGNATION SWMM DESIGN POINT DRAINAGE ARROW NEW & FUTURE IMPERVIOUS IMPROVEMENTS EXISTING IMPERVIOUS AREA (LID TREATED) PROPOSED CONTOURS EXISTING CONTOURS EXISTING BUILDING EXISTING CONCRETE EXISTING LANDSCAPING EXISTING GAS LINE EXISTING FIBER OPTIC EXISTING STORM DRAIN EXISTING WATER EXISTING SANITARY EXISTING TELEPHONE PROPOSED EXPANSION PROPOSED CONCRETE EXISTING ASPHALT 8'' SS 8'' SS 8'' SS 8'' SS 30 70 60 25 20 15 10 35 50 45 THE EXISTING ST. ELIZABETH ANN SETON SITE WAS EVALUATED IN A DRAINAGE AND EROSION CONTROL REPORT, PREPARED BY AYRES ASSOCIATES, AND DATED NOVEMBER 2, 1998. ALL VERTICAL DATA FOUND IN THIS REPORT IS BASED ON NGVD 29 DATUM. 2. THE ST. ELIZABETH ANN SETON SITE WAS EVALUATED FOR ADDITIONAL IMPROVEMENTS IN A DRAINAGE AND EROSION CONTROL REPORT, PREPARED BY AYRES ASSOCIATES, AND DATED JUNE 30, 2003. ALL VERTICAL DATA FOUND IN THIS REPORT IS BASED ON NGVD 29 DATUM. 3. THE TOPOGRAPHY AND ALL ELEVATION INFORMATION SHOWN ON THIS PLAN IS BASED ON THE NAVD 88 DATUM. 4. THE DRAINAGE BASINS SHOWN ON THIS PLAN ARE THE SAME SWMM BASINS IDENTIFIED IN THE TWO FINAL DRAINAGE REPORTS LISTED ABOVE. DATE REVISION DESCRIPTION REVISIONS FILENAME: 0031.0012.00_DRAINAGE 0031.0012.00 1" = 40' JULY 7, 2017 OF DESIGNED: CHECKED: JOB NO.: SCALE: DATE: SHEET NO.: 1" = 40' 0 40 80 scale feet CALL THE UTILITY NOTIFICATION CENTER OF COLORADO 3 DAYS BEFORE YOU DIG COLORADO CIVIL GROUP, INC. 811 OR 1-800-922-1987 www.UNCC.org DAH DAH 5110 GRANITE STREET, UNIT D LOVELAND, COLORADO 80538 (970) 278-0029 CCGCOLORADO CIVIL GROUP, INC. ENGINEERING CONSULTANTS 0" 1" BAR IS ONE INCH ON ORIGINAL DRAWING Mr. Michael D. DiTullio, Manager Mr. Terry Farrill, P.E., District Engineer All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. SOUTH FORT COLLINS SANITATION DISTRICT SCALE: 0031.0012.00 JOB NO: DAH CHECKED: DAH DESIGNED: FILE NAME: 0" 1" BAR IS ONE INCH ON ORIGINAL DRAWING 1" = 40' 0 40 80 scale feet CALL THE UTILITY NOTIFICATION CENTER OF COLORADO 3 DAYS BEFORE YOU DIG 811 OR 1-800-922-1987 www.UNCC.org Mr. Michael D. DiTullio, Manager Mr. Terry Farrill, P.E., District Engineer Date Date All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. SOUTH FORT COLLINS SANITATION DISTRICT NOTES: 1. SUB-GRADE BELOW ALL PAVEMENT SECTIONS SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 12" , ADJUSTED IN MOISTURE CONTENT (+ 2%) AND COMPACTED TO AT LEAST 95% OF THE MATERIAL'S MAXIMUM STANDARD PROCTOR DRY DENSITY AS DETERMINED IN ACCORDANCE WITH ASTM SPECIFICATION D698. CONTRACTOR SHALL PROOF-ROLL COMPACTED SUB-GRADE IN THE PRESENCE OF A GEOTECHNICAL ENGINEER OR CITY INSPECTOR. 2. IF SUB-GRADE MATERIAL IS UNSUITABLE (EXHIBITS PUMPING DURING PROOF-ROLL) IT SHALL EITHER BE RECONDITIONED OR REPLACED WITH SUITABLE ON-SITE MATERIALS. IF CONTRACTOR CHOOSES, STRUCTURAL FILL MAY BE IMPORTED, AT NO EXTRA COST TO OWNER, AND SHALL BE GRADED SIMILARLY TO CDOT CLASS 5 OR 6 AGGREGATE BASE. CONTRACTOR SHALL PROOF-ROLL ANY RE-WORKED SUB-GRADE PRIOR TO PLACEMENT OF AGGREGATE BASE COURSE. 3. IF CALLED FOR, AGGREGATE BASE COURSE SHALL BE ADJUSTED IN MOISTURE CONTENT (+ 2%) AND COMPACTED TO ACHIEVE A MINIMUM OF 95% OF THE MATERIAL'S MAXIMUM STANDARD PROCTOR DRY DENSITY AS DETERMINED IN ACCORDANCE WITH ASTM SPECIFICATION D698. CDOT CLASS D CONCRETE (4500 PSI) RECONDITIONED SUBGRADE #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A STAGE-STORAGE SIZING FOR DETENTION BASINS ST. ELIZABETH ANN SETON Check Basin Shape UD-Detention_v2.34.xls, Basin 7/6/2017, 9:41 PM 130 0.48 0.055 0.52 0.07 0.012 0.043 130 1.59 0.202 0.52 0.44 0.078 0.124 135 0.47 0.055 0.52 0.07 0.012 0.043 135 1.54 0.204 0.52 0.44 0.081 0.123 140 0.45 0.056 0.52 0.07 0.013 0.043 140 1.50 0.206 0.52 0.44 0.084 0.122 145 0.44 0.056 0.52 0.07 0.013 0.043 145 1.47 0.208 0.52 0.44 0.087 0.121 150 0.43 0.057 0.52 0.07 0.014 0.043 150 1.43 0.210 0.52 0.44 0.090 0.120 155 0.42 0.057 0.52 0.07 0.014 0.043 155 1.40 0.212 0.52 0.44 0.093 0.119 160 0.41 0.058 0.52 0.07 0.014 0.043 160 1.36 0.214 0.52 0.43 0.096 0.118 165 0.40 0.058 0.52 0.07 0.015 0.043 165 1.33 0.215 0.52 0.43 0.099 0.117 170 0.39 0.059 0.51 0.07 0.015 0.043 170 1.30 0.217 0.51 0.43 0.102 0.115 175 0.38 0.059 0.51 0.07 0.016 0.043 175 1.27 0.219 0.51 0.43 0.105 0.114 180 0.38 0.059 0.51 0.07 0.016 0.043 180 1.25 0.220 0.51 0.43 0.107 0.113 185 0.37 0.060 0.51 0.07 0.017 0.043 185 1.22 0.222 0.51 0.43 0.110 0.111 190 0.36 0.060 0.51 0.07 0.017 0.043 190 1.20 0.223 0.51 0.43 0.113 0.110 195 0.35 0.061 0.51 0.07 0.018 0.043 195 1.18 0.225 0.51 0.43 0.116 0.108 200 0.35 0.061 0.51 0.07 0.018 0.043 200 1.15 0.226 0.51 0.43 0.119 0.107 205 0.34 0.061 0.51 0.07 0.018 0.043 205 1.13 0.227 0.51 0.43 0.122 0.105 210 0.34 0.062 0.51 0.07 0.019 0.043 210 1.11 0.229 0.51 0.43 0.125 0.104 215 0.33 0.062 0.51 0.07 0.019 0.043 215 1.09 0.230 0.51 0.43 0.128 0.102 220 0.32 0.063 0.51 0.07 0.020 0.043 220 1.07 0.231 0.51 0.43 0.131 0.101 225 0.32 0.063 0.51 0.07 0.020 0.043 225 1.06 0.233 0.51 0.43 0.134 0.099 230 0.31 0.063 0.51 0.07 0.021 0.043 230 1.04 0.234 0.51 0.43 0.137 0.097 235 0.31 0.064 0.51 0.07 0.021 0.042 235 1.02 0.235 0.51 0.43 0.139 0.096 240 0.30 0.064 0.51 0.07 0.021 0.042 240 1.01 0.236 0.51 0.43 0.142 0.094 245 0.30 0.064 0.51 0.06 0.022 0.042 245 0.99 0.237 0.51 0.43 0.145 0.092 250 0.29 0.064 0.51 0.06 0.022 0.042 250 0.97 0.239 0.51 0.43 0.148 0.091 255 0.29 0.065 0.51 0.06 0.023 0.042 255 0.96 0.240 0.51 0.43 0.151 0.089 260 0.29 0.065 0.51 0.06 0.023 0.042 260 0.95 0.241 0.51 0.43 0.154 0.087 265 0.28 0.065 0.51 0.06 0.024 0.042 265 0.93 0.242 0.51 0.43 0.157 0.085 270 0.28 0.066 0.51 0.06 0.024 0.042 270 0.92 0.243 0.51 0.43 0.160 0.083 275 0.27 0.066 0.51 0.06 0.025 0.041 275 0.91 0.244 0.51 0.43 0.163 0.082 280 0.27 0.066 0.51 0.06 0.025 0.041 280 0.89 0.245 0.51 0.43 0.166 0.080 285 0.27 0.067 0.51 0.06 0.025 0.041 285 0.88 0.246 0.51 0.43 0.168 0.078 290 0.26 0.067 0.51 0.06 0.026 0.041 290 0.87 0.247 0.51 0.43 0.171 0.076 295 0.26 0.067 0.51 0.06 0.026 0.041 295 0.86 0.248 0.51 0.43 0.174 0.074 300 0.26 0.067 0.51 0.06 0.027 0.041 300 0.85 0.249 0.51 0.43 0.177 0.072 Mod. FAA Minor Storage Volume (cubic ft.) = 1,885 Mod. FAA Major Storage Volume (cubic ft.) = 5,550 Mod. FAA Minor Storage Volume (acre-ft.) = 0.0433 Mod. FAA Major Storage Volume (acre-ft.) = 0.1274 Determination of MAJOR Detention Volume Using Modified FAA Method (For catchments less than 160 acres only. For larger catchments, use hydrograph routing method) (NOTE: for catchments larger than 90 acres, CUHP hydrograph and routing are recommended) UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.34, Released November 2013 Determination of MINOR Detention Volume Using Modified FAA Method DETENTION VOLUME BY THE MODIFIED FAA METHOD ST. ELIZABETH ANN SETON UD-Detention_v2.34.xls, Modified FAA 7/6/2017, 9:40 PM scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 11, Sep 23, 2016 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 22, 2011—Apr 28, 2011 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Wind Erodibility Index—Larimer County Area, Colorado (WIND ERODIBILITY INDEX) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 2 of 3 Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 11, Sep 23, 2016 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 22, 2011—Apr 28, 2011 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Wind Erodibility Group—Larimer County Area, Colorado (WIND ERODIBILITY GROUP) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 2 of 3 of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 11, Sep 23, 2016 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 22, 2011—Apr 28, 2011 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group—Larimer County Area, Colorado (HYDROLOGIC SOIL GROUP) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 2 of 4 Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 11, Sep 23, 2016 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 22, 2011—Apr 28, 2011 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Drainage Class—Larimer County Area, Colorado (DRAINAGE CLASS) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/24/2017 Page 2 of 3