HomeMy WebLinkAboutLIVING OAKS - FDP - FDP170020 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLANCllY OF FORT COLLINS STANDARD STREET TREE NOTES 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CllY PROPERlY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CllY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. CONTACT THE CllY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. 3. STREET LANDSCAIPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CllY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR. 4. THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CllY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE. 5. SUBJECT TO APPROVAL BY THE CITY FORESTER -- STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILllY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CllY TO MEET SEPARATION STANDARDS. LANDSCAPE SCHEDULE LANDSCAPE LEGEND: QUANITIY SYMBOL 4" DEPTH SHREDDED CEDAR MULCH DECIDUOUS TREES LANDSCAPE NOTES: 1. ALL WORK SHALL CONFORM TO LOCAL CllY CODES. ALL LANDSCAIPING AND PLANTS TO BE LOCATED NOT TO INTERFERE WITH EXISTING OR PROPOSED UTILITIES. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES, LINES AND STRUCTURES PRIOR TO EXCAVATION OR TRENCHING. DAMAGE TO THESE UTILITIES SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THE OWNER OR LANDSCAPE ARCHITECT. 2. ALL PLANT MATERIALS SHALL BE IN ACCORDANCE WITH 2 + MN (AMERICAN ASSOCIATION OF NURSERYMEN) SPECIFICATIONS FOR NUMBER ONE GRADE. 3. PLANT QUANTITIES SHOWN FOR INFORMATION PURPOSES ONLY, CONTRACTOR TO VERIFY ALL QUANTITIES. 4. ALL TREE AND SHRUB LOCATIONS SHALL BE STAKED BY CONTRACTOR AND APPROVED BY LANDSCAPE ARCHITECT. 5. PLANT SUBSTITUTIONS WILL NOT BE PERMITTED WITHOUT APPROVAL FROM LANDSCAPE ARCHITECT. 6. PLANTS SHALL BE INSTALLED IMMEDIATELY UPON DELIVERY TO SITE, IF THIS IS NOT POSSIBLE, PLANTS ' ' ' ' ('"- ' ' 1 ·__/ ' ' ' ' ' ' ' ' : j" -���e---eO--c---=-""--='-: -,�,\, O,._�--[fC•- -•·--•-•J---•'fc,� 'f 9':r- r-. ,.--<-- ;, - ---cc�-·-:--,�- ,,-- - ' " l'---<RRIGATED TURF I (LOW WATER USAGE) co-<---1-- <1 . f' l '-,· �- . "'· <J, <1 ' ' _, ' ' ' L'.l <I ,.,, 4t ,1 \ . '· <J . ·L'.), - ... . . . . . . . \ -tfl . C -, --, --.>�> �> ---,�, LI <1 --'c --, , ,--,,c -- .0·. . r -----t-r -- <1 ,d ' . L'.l <J . ·'1 I ' '' "' <:! / I i "1 "' ' ' 4 ' --_ . ' i-----'-. ' <1 111111�--= UP DN u,._"--"'-/, �-->sc-,---"-�3 ,__A/ 2 _3 AMO AVS ACS 3 RHI --2 3 AMO ACS II 11111 ��- 3 3 AVS RHI UP u DN u I UP //j,/_ /-- ON l�=°'i L-I ' SJ '8 - ------ ---1 ' ' , � ---- _J I -- ..__ ...__ ...._ _)J -,�,- J '' I EXTENDS ZONE -VARIES FROM 3 ROOT DRIPLINE PER PROTECTION TREE TO SIZE DRIPLINE ·r EQUAL ·r DISTANCE TREE DRIP LINE, PROTECTION BETWEEN OR 1 FOOT AREA TRUNK FOR 1.5 AND EVERY X's DIAMETER WHICHEVER INCH IS GREATER OF TRUNK, TREE -ZONE PROTECT CANOPY 1 BRANCH LOWER PROTECTION BRANCHES OF FENCING PROVIDE AT 6' HIGH DRIPLINE CHAINUNK (MIN.) CONSTRUCTION -ZONE REQUIRED 2 TRUNK IF WHEELED EQUIPMENT PROJECTION INVOLVED \\1THIN 10' OR LESS AREA \\1NO THIN MATERIALS THE TREE SHALL PROTECTION BE STORED 0 0 0_·----- AMENDED SOIL MIX TO DEPTH PER SPECIFICATIONS 0 0 0� NOTE: SECTION EQUAL SPACING TYPICAL PLANT LAYOUT SEE PLANT LIST NOTES FOR �PLANT MATERIAL �''""c---MULCH ·-;-,----THOROUGHLY BACKFILL MIX TO DEPTH AMEND PER SPECIFICATIONS 1. 2. WHEN AIR AFTER POCKETS BACKFILLING PLANTING, TO FORM WATER AROUND THOROUGHLY PLANTS, DO NOT ALLOW 3. ONE AUL FOOT GRASSES FROM EDGE TO BE OF PLANTED PAVEMENT AT A MINIMUM OF O sc� ,E ��NNAIL PLANTING �.:;;;, ___ DO PRUNE NOT DAMAGED CUT LEADER. OR WEBBING AT 1/3-it----.�----J-I TREE HEIGHT DEAD WOOD AFTER PLANTING AND STAKING. PLANT FINISH TREE GRADE SO IS THAT 2" FIRST ABOVE ORDER HIGHEST ROOT. BACKFILL SUBGRADE MATERIAL 2 X ROOTBALL DI A. l+---2" 2 LODGEPOLE DIA. DRIVEN PINE IN POSTS FIRMLY KEEP OUTSIDE PLUMB . PLANTING W/TOPS PIT. EVEN. MULCH �� BURLAP REMOVE FROM WIREBASKET, TOP � OF REMOVE ROOTBALL 0-�C-�L�-DI_ , N�_O_US_TR_ E_E PL__A_N TNI__G_ EQUAL TRIANGULAR SPACING �---SHRUB CENTER + + + O-T �--CA ! ! -N G_LJ _LA_ R_S_H_RLJ_B_S_ P_AC_I N_G_ D_T -Sh-ru b--Spac-. e dwg AT PLANT GRADE ROOT BALL 3" FORM CONTINUOS BACKFILL SAUCER MIX WITH RIM - ----� ��"""""'+­ 11 -I 1 - PER SPECIFICATIONS SUBGRADE 11 I FIRM BASE NOTE: - 1-11 . - - - I -I ---�1- -1=1 1=1 - I 1= ------!-�11 .11 11 1 i'11 1111 ··-11 '1111 1 -111-1 MULCH 1. FORM WHEN BACKFILLING AROUND PLANTS, DO NOT ALLOW AIR POCKETS TO 3. 2. AFTER ALL GRASSES PLANTING, TO BE WATER PLANTED THOROUGHLY AT A MINIMUM OF ONE FOOT FROM EDGE OF PAVEMENT O �C�LIE��� P LANTING DAVISDAVI ARCHITECT 141 South College Ave. Ste. 102 Fort Collins Colorado 80524 970. 482. 1827 0 0 - en C en 0 � 0 <( t 0 0 LL +"' - (.9 Q) Q) z +"' - � > ro - 0 _J +"' w ro T'"" N N DESIGN DRAWING: NOT FOR CONSTRUCTION SET ISSUE FINAL PLAN 7.17.17 PDP SUBMITTAL #2 03.28.17 PDP SUBMITTAL 1 02.21.17 SHEET ISSUE REVISION DATE Revision Date 03/28/17 Project number OAKS Drawn by MT, CJ Checked by BD Landscape Details LP501 Scale As Noted <1 I I L __ lL --------------------------------------------------- --VINE FENCE PLANTING UP DN --2 3 ACS AMO --3 3 AVS RHI �----------------------------- ' <J " ' "1 <1 ' . •4 ' <1 "1 <1 • I. I . ,1 : ' • <1 "1 <I <J, • • <J2Ll,I • , I I i . 1· I r -- --- " I <1 • "1 <1 • LI ,:I <1 I ' I I " . I I . ' C �,- 1 I 5' LANDSCAPE LEGEND: 4" DEPTH SHREDDED CEDAR MULCH LANDSCAPE 1. ALL LANDSCAPING WORK NOTES: SHALL AND CONFORM PLANTS TO TO BE LOCAL LOCATED CITY NOT CODES. TO ALL INTERFERE CONTRACTOR WITH SHALL EXISTING VERIFY OR LOCATION PROPOSED OF UTILITIES. ALL UNDERGROUND TO EXCAVATION UTILITIES, OR TRENCHING. LINES AND DAMAGE STRUCTURES TO THESE PRIOR UTILITIES NO COST SHALL TO THE BE OWNER REPAIRED OR LANDSCAPE BY THE CONTRACTOR ARCHITECT. AT 2. ALL AAN PLANT (AMERICAN MATERIALS ASSOCIATION SHALL OF BE NURSERYMEN) IN ACCORDANCE WITH 3. PLANT SPECIFICATIONS QUANTITIES FOR SHOWN NUMBER FOR ONE INFORMATION GRADE. PURPOSES 4. ALL ONLY, TREE CONTRACTOR AND SHRUB TO LOCATIONS VERIFY ALL SHALL QUANTITIES. BE STAKED BY 5. PLANT CONTRACTOR APPROVAL SUBSTITUTIONS FROM AND LANDSCAPE APPROVED WILL NOT ARCHITECT. BY BE LANDSCAPE PERMITTED ARCHITECT. WITHOUT 6. PLANTS DELIVERY SHALL TO SITE, BE INSTALLED IF THIS IS IMMEDIATELY NOT POSSIBLE, UPON PLANTS DEHYDRATION. SHALL BE HEELED IN AND WATERED TO PREVENT 7. IN 6" 20% TO SOIL ORGANIC ALL MIX SHRUB CONSISTING PEAT BEDS. & 60% OF TOPSOIL 20% ORGANIC SHALL COMPOST, BE TILLED 8. INSTALL PLANTING 4" AREAS. DEPTH OF ORGANIC WOOD MULCH IN ALL 9. NO AND TREES SEWER SHALL MAINS BE OR PLANTED WITHIN 6' WITHIN OF SERVICE 1 Q' OF WATER LINES. NO AND SHRUBS SEWER MAINS SHALL OR BE SERVICE PLANTED LINES. WITHIN 4' OF WATER 0 2.5' 5' 10' NOR TH DAVISDAVI ARCHITECT 141 South College Ave. Ste. 102 Fort Collins Colorado 80524 970. 482. 1827 0 0 - en en 0 � 0 <( t 0 0 LL +"' - (.9 Q) Q) z +"' - � > ro - 0 _J +"' en ro T'"" N N DESIGN DRAWING: NOT FOR CONSTRUCTION SET ISSUE FINAL PLAN 7.17.17 PDP SUBMITTAL #2 03.28.17 PDP SUBMITTAL 1 02.21.17 SHEET ISSUE REVISION DATE Revision Date 05/1/17 Project number OAKS Drawn by MT, CJ Checked by BD Overall Planting Plan LP100 Scale As Noted SHALL BE HEELED IN AND WATERED TO PREVENT DEHYDRATION. 7. 6" SOIL MIX CONSISTING OF 20% ORGANIC COMPOST, 20% ORGANIC PEAT & 60% TOPSOIL SHALL BE TILLED IN TO ALL SHRUB BEDS. 8. INSTALL 4" DEPTH OF ORGANIC WOOD MULCH IN ALL PLANTING AREAS. 9. NO TREES SHALL BE PLANTED WITHIN 1 O' OF WATER AND SEWER MAINS OR WITHIN 6' OF SERVICE LINES. 7 X NO SHRUBS SHALL BE PLANTED WITHIN 4' OF WATER AND SEWER MAINS OR SERVICE LINES. ORNAMENTAL GRASSES 39 0 56 0 6 0 12 @ PERENNIALS � 8 AMO 9 ACS 12 AVS 12 RHI IVY 61 BOTANIC NAME COMMON NAME SIZE HEIGHT QUERCUS BUCKLEY! TEXAS RED OAK 3" CAL./B&B 60-75' JUNIPERUS SCOPULORUM SKYROCKET JUNIPER 2" CAL./B&B 15' -20' 'SKYROCKET' MUHLENBERGIA REVERCHONII UNDAUNTED MUHLY GRASS 1 GAL. 15"-18" SCHIZACHYRIUM SCOPARIUM 'PRAIRIE BLUES' LlffiE BLUESTEM 1 GAL. 2'-3' MISCANTHUS SINENSIS MAIDEN GRASS 1 GAL. 3-4' 'YAKUSHIMA' DWARF NASSELLA TENUISSIMA MEXICO FEATHERGRASS 1 GAL. 12·-24· ACHILLEA X 'MOONSHINE' MOONSHINE YARROW 1 GAL. 24-30" AGASTACHE CANA 'SINNING' SONORAN SUNSET HYSSOP 1 GAL. 15" ARTEMISIA VERSICOLOR SEA FOAM SAGE 1 GAL. 10· 'SEA FOAM' RUDBECKIA HIRTA BLACK-EYED SUSAN 1 GAL. 24-36" PASSIFLORA INCARNATA PASSION FLOWER 1 GAL. SPREAD 50-60' 3'-4' 18"-24" 2' 3'-4' 20· -24" 18-24" 15" 20· 12-24" DAVISDAVI ARCHITECT 141 South College Ave. Ste. 102 Fort Collins Colorado 80524 970. 482. 1827 0 0 - en C en 0 � 0 <( t 0 0 LL +"' - (.9 Q) Q) z +"' Cl) � > ro - 0 _J +"' en ro w T'"" DESIGN DRAWING: NOT FOR CONSTRUCTION SET ISSUE FINAL PLAN 7.17.17 PDP SUBMITTAL #2 03.28.17 PDP SUBMITTAL 1 02.21.17 SHEET ISSUE REVISION DATE Revision Date 05/1/17 Project number OAKS Drawn by MT, CJ Checked by BD Landscape Schedule and Notes LP001 Scale As Noted