Loading...
HomeMy WebLinkAboutTHE GREEN SOLUTION - PDP/FDP - FDO150045 - REPORTS - (9)COVER SHEET THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:31 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Cover Sheet.dwg Updated By: lmoran A PORTION OF THE SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT A POINT 684.8 FEET NORTH OF THE SOUTHWEST CORNER OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN; THENCE NORTH 75.00 FEET; THENCE EAST 230.00 FEET; THENCE SOUTH 75.00 FEET; THENCE WEST 230.00 FEET TO THE POINT OF BEGINNING; EXCEPT THE WEST 40.00 FEET THEREOF HERETOFORE CONVEYED TO THE BOARD OF COUNTY COMMISSIONERS BY DEED RECORDED IN BOOK 599 AT PAGE 295; ALSO EXCEPT THAT PORTION CONVEYED BY DEED RECORDED OCTOBER 20, 2011 AT RECEPTION NO. 20110064350. VICINITY MAP LEGAL DESCRIPTION SITE PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR PROPERTY LINE EASEMENT CENTERLINE SETBACK BUILDING EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPOSED SPILL CURB AND GUTTER PROPOSED SIDEWALK SAWCUT PROPOSED STORM DRAIN EXISTING STORM DRAIN PROPOSED CATCH BASIN PROPOSED DRAIN MANHOLE PROPOSED SANITARY SEWER EXISTING SANITARY SEWER EXISTING WATER MAIN EXISTING GAS LINE EXISTING ELECTRICAL EXISTING TELECOM EXISTING SEWER MANHOLE EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED WATER METER PROPOSED WATER PROPOSED SEWER CLEANOUT GENERAL NOTES THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:31 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Cover Sheet.dwg Updated By: lmoran PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR 1. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF PUBLIC IMPROVEMENTS SHALL MEET OR EXCEED THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LARIMER COUNTY URBAN AREA STREET STANDARDS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE MOST RESTRICTIVE STANDARD SHALL APPLY. ALL WORK SHALL BE INSPECTED AND APPROVED BY THE LOCAL ENTITY. 2. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE. 3. THESE PUBLIC IMPROVEMENT CONSTRUCTION PLANS SHALL BE VALID FOR A PERIOD OF THREE YEARS FROM THE DATE OF APPROVAL BY THE LOCAL ENTITY ENGINEER. USE OF THESE PLANS AFTER THE EXPIRATION DATE WILL REQUIRE A NEW REVIEW AND APPROVAL PROCESS BY THE LOCAL ENTITY PRIOR TO COMMENCEMENT OF ANY WORK SHOWN IN THESE PLANS. 4. THE ENGINEER WHO HAS PREPARED THESE PLANS, BY EXECUTION AND/OR SEAL HEREOF, DOES HEREBY AFFIRM RESPONSIBILITY TO THE LOCAL ENTITY, AS BENEFICIARY OF SAID ENGINEER¶S WORK, FOR ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS, AND APPROVAL OF THESE PLANS BY THE LOCAL ENTITY ENGINEER SHALL NOT RELIEVE THE ENGINEER WHO HAS PREPARED THESE PLANS OF ALL SUCH RESPONSIBILITY. FURTHER, TO THE EXTENT PERMITTED BY LAW, THE ENGINEER HEREBY AGREES TO HOLD HARMLESS AND INDEMNIFY THE LOCAL ENTITY, AND ITS OFFICERS AND EMPLOYEES, FROM AND AGAINST ALL LIABILITIES, CLAIMS, AND DEMANDS WHICH MAY ARISE FROM ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS. 5. ALL SANITARY SEWER, STORM SEWER, AND WATER LINE CONSTRUCTION, AS WELL AS POWER AND OTHER ³DRY´UTILITY INSTALLATIONS, SHALL CONFORM TO THE LOCAL ENTITY STANDARDS AND SPECIFICATIONS CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENTITY ENGINEER. 6. THE TYPE, SIZE, LOCATION AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK BEFORE COMMENCING NEW CONSTRUCTION. THE DEVELOPER SHALL BE RESPONSIBLE FOR UNKNOWN UNDERGROUND UTILITIES. 7. THE ENGINEER SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) AT 1-800-922-1987, AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING EXCAVATION OR GRADING, TO HAVE ALL REGISTERED UTILITY LOCATIONS MARKED. OTHER UNREGISTERED UTILITY ENTITIES (I.E. DITCH / IRRIGATION COMPANY) ARE TO BE LOCATED BY CONTACTING THE RESPECTIVE REPRESENTATIVE. UTILITY SERVICE LATERALS ARE ALSO TO BE LOCATED PRIOR TO BEGINNING EXCAVATION OR GRADING. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 8. THE DEVELOPER SHALL BE RESPONSIBLE FOR PROTECTING ALL UTILITIES DURING CONSTRUCTION AND FOR COORDINATING WITH THE APPROPRIATE UTILITY COMPANY FOR ANY UTILITY CROSSINGS REQUIRED. 9. IF A CONFLICT EXISTS BETWEEN EXISTING AND PROPOSED UTILITIES AND/OR A DESIGN MODIFICATION IS REQUIRED, THE DEVELOPER SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. DESIGN MODIFICATION(S) MUST BE APPROVED BY THE LOCAL ENTITY PRIOR TO BEGINNING CONSTRUCTION. 10. THE DEVELOPER SHALL COORDINATE AND COOPERATE WITH THE LOCAL ENTITY, AND ALL UTILITY COMPANIES INVOLVED, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION AND WITH A MINIMUM DISRUPTION OF SERVICE. THE DEVELOPER SHALL BE RESPONSIBLE FOR CONTACTING, IN ADVANCE, ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE AS WELL AS THE UTILITY COMPANIES. 11. NO WORK MAY COMMENCE WITHIN ANY PUBLIC STORM WATER, SANITARY SEWER OR POTABLE WATER SYSTEM UNTIL THE DEVELOPER NOTIFIES THE UTILITY PROVIDER. NOTIFICATION SHALL BE A MINIMUM OF 2 WORKING DAYS PRIOR TO COMMENCEMENT OF ANY WORK. AT THE DISCRETION OF THE WATER UTILITY PROVIDER, A PRE-CONSTRUCTION MEETING MAY BE REQUIRED PRIOR TO COMMENCEMENT OF ANY WORK. NORTH COLLEGE AVENUE EXISTING FENCE TO BE REMOVED EXISTING OVERHEAD ELECTRIC TO REMAIN EXISTING PLANTER BOX TO BE DEMOLISHED ~41 SY EXISTING STRUCTURE TO BE DEMOLISHED ~22 SY EXISTING CONCRETE TO BE REMOVED ~933 SY EXISTING ASPHALT TO BE REMOVED EXISTING OVERHEAD ELECTRIC TO BE REMOVED ~103 SY EXISTING CONCRETE TO BE REMOVED EXISTING BUILDING TO REMAIN BUILDING HEIGHT 15 FT. EXISTING BOWLING ALLEY EXISTING LIQUOR STORE EXISTING CAR SALES ~840 SF LIMITS OF EXISTING BUILDING TO BE DEMOLISHED CAP SANITARY CONNECTION AT MAIN SAWCUT ASPHALT APPROXIMATE LOCATION OF EXISTING SANITARY SERVICE TO BE REMOVED EX 10" SANITARY LINE EX 8" WATER LINE EX 3 4" WATER SERVICE TO REMAIN EX ELECTRIC TRANSFORMERS TO REMAIN SAWCUT ASPHALT AT PROPERTY LINE 15.0' UTILITY EASEMENT EX 8' SIDEWALK TO REMAIN PROPERTY LINE ~276 SY MILL AND OVERLAY EXISTING PAVEMENT SIDEWALK TO BE REMOVED AND REPLACED ~19 SY EXISTING CONCRETE TO BE REMOVED ~8 SY EXISTING CONCRETE PAD TO BE REMOVED EXISTING TREES TO BE REMOVED EXISTING TREES TO REMAIN EXISTING TREES TO BE REMOVED FEMA FLOOD ZONE "AE" EXISTING BUILDING TBA: 2330 S.F. BUILDING HEIGHT: 15 FT. EXISTING BOWLING ALLEY EXISTING LIQUOR STORE NORTH COLLEGE AVENUE EXISTING CAR SALES APPROXIMATE LIMITS OF BUILDING EXPANSION TBA: 2470 S.F. BUILDING HEIGHT: 17 FT. 9.00' (TYP) 8.00' (TYP) 8.00' (TYP) 6.00' 5.00' 5.00' 5.00' COMPACTOR ENCLOSURE (SEE ARCH PLANS) 5.00' 8.00' 23.00' COVERED BICYCLE RACKS (SEE ARCH PLANS) MAIN INGRESS/EGRESS TO NORTH COLLEGE AVENUE 8' SIDEWALK 8.0' SIDEWALK 10.61' 40.13' EXISTING MONUMENT SIGN PROPOSED CURB RAMP APN:9701300035 PROPOSED STEPS LANDSCAPE AREA LANDSCAPE AREA LANDSCAPE AREA SAWCUT LINE LANDSCAPE AREA (SEE LANDSCAPE PLANS) PROPOSED CURB AND GUTTER 17.00' (TYP) N: 1460995.76 E: 3117769.43 N: 1460996.65 E: 3117677.59 15.0' EXISTING BUILDING FFE = 4968.9' EXISTING BOWLING ALLEY EXISTING LIQUOR STORE NORTH COLLEGE AVENUE EXISTING CAR SALES 15.0' UTILITY EASEMENT 1.6% 0.8% 1.0% EX. 0.8% EX. 0.5% EX. 0.6% SAWCUT LINE 0.7% CROSS PAN 1.5% HC PARKING AREA 2% MAX IN ANY DIRECTION 2.0% 2.0% 1.9% 2.0% 1.2% MATCH EXISTING 0.9% 0.8% 1.9% 8.1% 4.6% SAWCUT LINE 2.0% 0.7% 0.5% 0.7% 2.0% 1.0% 2.3% 1.8% 5.4% 3.8% 0.9% SAWCUT LINE 1.9% 2.0% PROPOSED BUILDING EXPANSION FFE = 4968.90' SWALE CENTERLINE FEMA 100-YEAR POUDRE RIVER FLOODPLAIN ZONE AE EX. 1.4% EX. 0.7% 0 SCALE: 1"=10' 5 10 20 PROJ. MGR.: DRAWN BY: EXISTING BUILDING FFE=4968.9 EXISTING BOWLING ALLEY EXISTING LIQUOR STORE NORTH COLLEGE AVENUE EXISTING CAR SALES APPROXIMATE LOCATION OF EXISTING 10" SAN EX. 3/4" WATER SERVICE EX. 10" VCP SAN EX. 8" WATERMAIN EX. OVERHEAD ELECTRIC EXISTING GAS CONNECT TO EXISTING INLET EXISTING MANHOLE APPROXIMATE LOCATION OF EXISTING STORM LINE AND STRUCTURES 15.0' UTILITY EASEMENT PROPOSED 4" SANITARY CONNECTION INV: 4959.34 (SEE ARCH PLANS FOR EXACT LOCATION) 92.5' PUBLIC R.O.W. MAIN INGRESS/EGRESS TO NORTH COLLEGE AVENUE W/ CROSSPAN 8.0' SIDEWALK 8.0' SIDEWALK EXISTING GAS EXISTING GAS CONCRETE CROSSPAN PROPERTY LINE PROPERTY LINE STORM A (SEE SHEET 07) STORM B (SEE SHEET 08) CONNECT TO EXISTING 10" SAN INV: 4959.20 PROPOSED BUILDING EXPANSION FFE=4968.90 CONCRETE CROSSPAN CHASE FEMA FLOOD ZONE "AE" FEMA FLOOD ZONE "X" CONCRETE TRICKLE CHANNEL WALL OPENING 0 SCALE: 1"=10' 5 10 20 PROJ. MGR.: DRAWN BY: DATE: EXISTING BUILDING FFE=4968.9 EX. 3/4" WATER SERVICE CONNECT TO EXISTING INLET APPROXIMATE LOCATION OF EXISTING STORM LINE AND STRUCTURES 9+86 10+00 11+00 12+00 12+45 SEE STORM PLAN B ON SHEET 08. PROPOSED BUILDING EXPANSION FFE=4968.90 EXISTING GAS EXISTING CAR SALES FEMA FLOOD ZONE "AE" FEMA FLOOD ZONE "X" NORTH COLLEGE AVENUE 4960 4965 4970 4960 4965 4970 9+50 10+00 11+00 12+00 12+50 9+50 10+00 11+00 12+00 12+50 27' ~ 12" PVC @ 0.50% 60' ~ 12" PVC @ 0.50% 10' ~ 12" PVC @ 0.50% 14' ~ 12" RCP @ 1.00% 140' ~ 8" PVC @ 0.44% PR STM BASIN 05 STA: 10+96.70, 0.00' RIM: 4968.80 INV IN: 4962.18 (E-8") INV IN: 4962.38 (N-12") INV OUT: 4962.18 (W-12") CUT: 7.1 PR STM MH 04 STA: 10+69.47, 0.00' RIM: 4968.54 INV IN: 4962.05 (E-12") INV OUT: 4962.05 (S-12") CUT: 6.5 PR STM MH 03 STA: 10+09.55, 0.00' RIM: 4968.05 INV IN: 4961.75 (N-12") INV OUT: 4961.75 (W-12") CUT: 6.3 EX STM MH 01 STA: 9+85.59, 0.00' RIM: 4967.64 INV IN: 4961.56 (E-12") INV OUT: 4961.46 (W-12") PR STM INLET 06 STA: 12+36.85, -0.01' L NORTH COLLEGE AVENUE EX. 3/4" WATER SERVICE EX. 8" WATERMAIN EXISTING GAS 15.0' UTILITY EASEMENT EXISTING GAS CONCRETE CROSSPAN 10+00 11+00 11+26 SEE STORM PLAN A ON SHEET 07. EXISTING BUILDING FFE=4968.9 PROPOSED BUILDING EXPANSION FFE=4968.90 4961 4965 4970 4961 4965 4970 9+50 10+00 11+00 11+50 9+50 10+00 11+00 11+50 PR STM BASIN 07 STA: 10+66.65, 0.00' RIM: 4969.00 INV IN: 4963.25 (E-12") INV OUT: 4963.05 (S-12") CUT: 6.4 53' ~ 12" PVC @ 1.00% 67' ~ 12" PVC @ 1.00% PR STM BASIN 05 STA: 10+96.70, 0.00' RIM: 4968.80 INV IN: 4962.18 (E-8") INV IN: 4962.38 (N-12") INV OUT: 4962.18 (W-12") CUT: 7.1 PR STM INLET 08 STA: 11+19.33, 0.00' RIM: 4967.63 INV OUT: 4963.78 (W-12") CUT: 4.4 EXISTING GROUND AT CENTERLINE OF PIPE PROPOSED GROUND AT CENTERLINE OF PIPE EXISTING GAS LINE CROSSING EXISTING 3 4" WATER SERVICE CROSSING 1.00' 0.62' PROJ. MGR.: DRAWN BY: DATE: OF SHEET EXISTING BUILDING FFE = 4968.9 EXISTING BOWLING ALLEY EXISTING LIQUOR STORE NORTH COLLEGE AVENUE EXISTING CAR SALES PROPOSED BUILDING FFE = 4968.90 CF X X X X X X X X X X X X X X X X X X X X X X X X X X X X X CF CF CF CF LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE CF CW IPS SSA PT RS VTC SD IPS IPA IPS SP SD SD SD SF SF SF CF PERIMETER SILT DIKES AND FENCES INSTALL INLET PROTECTION INSTALL STORM FACILITIES INSTALL INLET PROTECTION BEGIN ROUGH GRADING STAGING AREA VEHICLE TRACKING CONTROL FOUNDATION/BUILDING CONSTRUCTION APRON ON THIS SIDE OF THE DIKE SHALL BE FOLDED UNDER THE DIKE SECTION 20" AND GLUED DOWN DT-SDP 11/01/07 NOTES: 1. INSTALLED SILT DIKE UNIT SHALL HAVE CONTINUOUS AND FIRM CONTACT WITH PAVEMENT. 2. ADHESIVES SHALL BE LIQUID NAIL OR APPROVED EQUAL FOR CONCRETE PAVEMENT APPLICATIONS AND EMULSIFIED ASPHALT FOR ASPHALT APPLICATIONS. ADHESIVE SHALL BE PLACED WHERE THE UNITS OVERLAP AND A 20" STRIP ALONG BOTH EDGES. OVERLAP PER MANUFACTURER'S RECOMMENDATIONS DIKE PLAN VIEW ADHESIVE ADHESIVE ADHESIVE ADHESIVE FLOW CONSTRUCTION AREA APRON EXISTING CONCRETE OR ASPHALT PAVEMENT SECTION A-A ADHESIVE FLOW ADHESIVE N.T.S. SILT DIKE (ON EXISTING PAVEMENT) 20" 20" A A (MODIFIED) CEC PROVIDED PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR EROSION CONTROL DETAILS - 1 THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:34 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\Erosion Control Details.dwg Updated By: mmcguire PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR EROSION CONTROL DETAILS - 2 THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:34 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\Erosion Control Details.dwg Updated By: mmcguire PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR CONSTRUCTION DETAILS THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:34 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\Construction Details.dwg Updated By: mmcguire PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR CONSTRUCTION DETAILS THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:34 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\Construction Details.dwg Updated By: mmcguire A CONCRETE TRICKLE CHANNEL DETAIL 1.0' 1.0' 1" 6" CONCRETE COMPACT SUBGRADE TO 95% DENSITY Ύ/DE^/KE^DzsZzц1 2" DEPENDING ON PRECASTER BUILD CONFIGURATION PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR CONSTRUCTION DETAILS THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:34 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\Construction Details.dwg Updated By: mmcguire FINAL GRADING/FINAL STABILIZATION PAVING DEMOLISH PAVEMENT AND BUILDING DEC NOTE: GENERAL CONTRACTOR TO COMPLETE TABLE WITH THEIR ESTIMATED PROJECT SCHEDULE CONSTRUCTION SEQUENCE MAY JUN SEP OCT NOV JAN FEB MAR APR 1) CONTRACTOR MUST COMPLETE TABLE WITH ESTIMATED DATES OF PROJECT ACTIVITIES PRIOR TO BMP CERTIFICATION. JUL AUG SEP OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG INSTALL CURB AND GUTTER SEQUENCE SCHEDULE 0 SCALE: 1"=10' 5 10 20 PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR EROSION & SEDIMENT CONTROL PLAN THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:33 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\Erosion Control Plan.dwg Updated By: lmoran STORMWATER QUALITY BEST MANAGEMENT PRACTICES SHALL BE IMPLEMENTED TO MINIMIZE SOIL EROSION, SEDIMENTATION, INCREASED POLLUTANT LOADS, AND CHANGED WATER FLOW CHARACTERISTICS RESULTING FROM LAND DISTURBING ACTIVITY, TO THE MAXIMUM EXTENT PRACTICABLE, SO AS TO MINIMIZE POLLUTION OF RECEIVING WATERS. EROSION AND SEDIMENT CONTROL NOTES: 1. THE CITY STORMWATER DEPARTMENT EROSION CONTROL INSPECTOR MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR TO ANY CONSTRUCTION ON THIS SITE. 2. ALL REQUIRED BMPS SHALL BE INSTALLED PRIOR TO ANY LAND DISTRUBING ACTIVITY (STOCKPILING, STRIPPING, GRADING, ETC). ALL OF THEIR REQUIRED EROSION CONTROL MEASURES SHALL BE INSTALLED AT THE APPROPRIATE TIME IN THE CONSTRUCTION SEQUENCE AS INDICATED IN THE APPROVED PROJECT SCHEDULE, CONSTRUCTION PLANS, AND EROSION CONTROL REPORT. 3. PRE-DISTRUBANCE VEGETATION SHALL BE PROTECTED AND RETAINED WHEREVER POSSIBLE. REMOVAL OR DISTURBANCE OF EXISTING VEGETATION SHALL BE LIMITED TO THE AREA REQUIRED FOR IMMEDIATE CONSTRUCTION OPERATIONS, AND FOR THE SHORTEST PRACTICAL PERIOD OF TIME. 4. ALL SOILS EXPOSED DURING LAND DISTURBING ACTIVITY (STRIPPING, GRADING, UTILITY INSTALLATIONS, STOCKPILING, FILLING, ETC.) SHALL BE KEPT IN A ROUGHENED CONDITION BY RIPPING OR DISKING ALONG LAND CONTOURS UNTIL MULCH, VEGETATION, OR OTHER PERMANENT EROSION CONTROL IS INSTALLED. NO SOILS IN AREAS OUTSIDE PROJECT STREET RIGHTS OF WAY SHALL REMAIN EXPOSED BY LAND DISTURBING ACTIVITY FOR MORE THAN THIRTY (30) DAYS BEFORE REQUIRED TEMPORARY OR PERMANENT EROSION CONTROL (E.G. SEED/MULCH, LANDSCAPING, ETC.) IS INSTALLED, UNLESS OTHERWISE APPROVED BY THE STORMWATER DEPARTMENT. 5. THE PROPERTY MUST BE WATERED AND MAINTAINED AT ALL TIMES DURING CONSTRUCTION ACTIVITIES SO AS TO PREVENT WIND-CAUSED EROSION. ALL LAND DISTURBING ACTIVITIES SHALL BE IMMEDIATELY DISCONTINUED WHEN FUGITIVE DUST IMPACTS ADJACENT PROPERTIES, AS DETERMINED BY THE CITY ENGINEERING DEPARTMENT. 6. ALL TEMPORARY (STRUCTURAL) EROSION CONTROL MEASURES MUST BE INSPECTED AND REPAIRED OR RECONSTRUCTED AS NECESSARY AFTER EACH RUNOFF EVENT AND EVERY 14 DAYS IN ORDER TO ASSURE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. ALL RETAINED SEDIMENTS, PARTICULARLY THOSE ON PAVED ROADWAY SURFACES, SHALL BE REMOVED AND DISPOSED OF IN A MANNER AND LOCATION SO AS NOT TO CAUSE THEIR RELEASE INTO ANY DRAINAGEWAY. 7. NO SOIL STOCKPILE SHALL EXCEED TEN (10) FEET IN HEIGHT. ALL SOIL STOCKPILES SHALL BE PROTECTED FROM SEDIMENT TRANSPORT BY SURFACE ROUGHENING, WATERING, AND PERIMETER SILT FENCING. ANY SOIL STOCKPILE REMAINING AFTER 30 DAYS SHALL BE SEEDED AND MULCHED. 8. CITY ORDINANCE PROHIBITS THE TRACKING, DROPPING, OR DEPOSITING OF SOILS OR ANY OTHER MATERIAL ONTO CITY STREETS BY TO FROM ANY VEHICLE. ANY INADVERTENT DEPOSITED MATERIAL SHALL BE CLEANED IMMEDIATELY BY THE CONTRACTOR. PROPERTY LINE LIMITS OF DISTURBANCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING STORM SEWER EROSION CONTROL LEGEND EROSION CONTROL BLANKET PER UDFCD DETAIL EC-6 CONCRETE WASHOUT AREA PER UDFCD DETAIL MM-1 INLET PROTECTION FOR AREA INLETS PER UDFCD DETAIL SC-6 SILT DIKE PER DETAIL SD CF CW ECB IPA SD SSA VTC CONSTRUCTION FENCE STABILIZED STAGING AREA PER UDFCD DETAIL SM-6 VEHICLE TRACKING CONTROL PER UDFCD DETAIL SM-4 FINAL STABILIZATION (PER APPROVED LANDSCAPE PLANS) STOCKPILE MANAGEMENT PER SP UDFCD DETAIL MM-2 INLET PROTECTION, CURB IPS PER UDFCD DETAIL SC-6 PT PORTABLE TOILET PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR RS ROCK SOCK PER UDFCD DETAIL SC-5 SILT FENCE PER CITY OF FORT X SF COLLINS DETAIL D-28 PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR STORM PLAN & PROFILE B THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:33 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\STM P&P.dwg Updated By: lmoran PROFILE STORM B 0 SCALE: 1"=10' VERTICAL SCALE: 1"=10' 5 10 20 RIM: 4966.22 INV OUT: 4962.80 (W-8") CUT: 3.9 EXISTING GROUND AT CENTERLINE OF PIPE PROPOSED GROUND AT CENTERLINE OF PIPE EX STM INLET 02 STA: 10+00.00, 0.02' R RIM: 4967.37 INV IN: 4961.70 (E-12") INV OUT: 4961.70 (W-12") CUT: 6.2 EXISTING GAS LINE CROSSING 2.32' PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR STORM PLAN & PROFILE A THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:33 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\STM P&P.dwg Updated By: lmoran PROFILE STORM A 0 SCALE: 1"=10' VERTICAL SCALE: 1"=10' 5 10 20 OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR OVERALL UTILITY PLAN THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:32 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Utility Plans\Utility Plan.dwg Updated By: lmoran ~144' TO FIRE HYDRANT UTILITY NOTES: 1. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S). 2. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS, CERTIFICATION OF THE DRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BY SUBMITTED TO AND APPROVED BY THE STORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BY SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT. 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES AND FEATURES PRIOR TO CONSTRUCTION. 4. REFER TO SHEETS 07 AND 08 FOR STORM SEWER PLAN AND PROFILES WITH DETAILED DESIGN INFORMATION. 5. ALL PROPOSED STORM SEWER PIPE AND STRUCTURES SHOWN ON THESE PLANS ARE PRIVATE AND ARE TO BE OWNED AND MAINTAINED BY THE PROPERTY OWNER OR FUTURE ASSIGNS. 6. ALL DOMESTIC WATER SERVICE LINES SHOWN ON THESE PLANS ARE PRIVATE AND ARE TO BE OWNED AND MAINTAINED BY THE PROPERTY OWNER OR FUTURE ASSIGNS. 7. ALL PROPOSED SANITARY SEWER SERVICE LINES, SHOWN ON THESE PLANS ARE PRIVATE AND ARE TO BE OWNED AND MAINTAINED BY THE PROPERTY OWNER OR FUTURE ASSIGNS. DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR GRADING AND DRAINAGE PLAN THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 3/9/2016 12:19 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Grading Plan.dwg Updated By: mmcguire ~144' TO FIRE HYDRANT GRADING PLAN NOTES: 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES AND FEATURES PRIOR TO CONSTRUCTION. 2. CONTRACTOR SHALL MATCH EXISTING GRADES AT PROPERTY AND NOT GRADE ON ADJACENT PROPERTIES WITHOUT PRIOR WRITTEN CONSENT FROM PROPERTY OWNER. 3. THE GRADING PLAN INDICATES THE FINISHED GROUND ELEVATIONS AROUND THE PERIMETER OF THE BUILDINGS. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL AND/OR STRUCTURAL PLANS FOR FOUNDATION TYPES AND FOOTING ELEVATIONS. 4. PER ADA REQUIREMENTS, HANDICAP PARKING SPACES SHALL HAVE A MAXIMUM SLOPE OF 2.0% IN ANY DIRECTION. CONTRACTOR SHALL TAKE CARE DURING PAVING TO ENSURE THAT THIS REQUIREMENT IS MET. 5. ALL HANDICAP RAMPS AND SIDEWALKS SHALL BE CONSTRUCTED WITH A MAXIMUM CROSS SLOPE OF 2.0% OR LESS. 6. ALL RADII LABELS ON THE PLAN SHEET FOR CURB AND GUTTER RETURNS, NOSES, OR CURVES ARE TO THE FLOWLINE. ALL RADII FOR PARKING STALL RETURNS ARE 5.0' TO THE FLOWLINE, UNLESS OTHERWISE NOTED. 7. THE CONTRACTOR SHALL CALL 811 PRIOR TO ANY WORK PERFORMED TO LOCATE UTILITIES AND SHALL CONTACT THE OWNER IF UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. 8. ALL SPOT ELEVATIONS ARE FLOW LINE ELEVATIONS, UNLESS OTHERWISE NOTED. CONSTRUCTION NOTES INSTALL CROSS PAN PER LARIMER COUNTY URBAN AREA STREET STANDARDS CONSTRUCTION DRAWING 710, SEE SHEET 12. INSTALL TRICK CHANNEL PER DETAIL A, SEE SHEET 13. UTILITY EASEMENT MILL AND OVERLAY EXISTING ASPHALT PAVEMENT CHASE 91.85' (SEE ARCH PLANS) 28.05' (SEE ARCH PLANS) R2.00' R2.00' R2.00' PROPOSED CONCRETE WALK PROPOSED ASPHALT PROPOSED CONCRETE WALK PROPOSED ASPHALT PAINTED WHITE PARKING STRIPE (TYP) FLOOD ZONE X FLOOD ZONE AE SAWCUT LINE BIORETENTION FACILITY TRICKLE CHANNEL PROPOSED CURB 0 SCALE: 1"=10' 5 10 20 SITE PLAN THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:32 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Site Plan.dwg Updated By: lmoran PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR 1. SIDEWALK WITHIN THIS PROJECT SHALL BE 5' WIDE CONCRETE UNLESS OTHERWISE NOTED. 2. PARKING LOT DIMENSIONS ARE TO THE FLOWLINE UNLESS OTHERWISE NOTED. 3. TYPICAL PARKING STALL DIMENSION SHOWN ON THIS PLAN IS 9' X 17' 4. PARKING LOT CURB RADII ARE 5' AT FLOWLINE UNLESS OTHERWISE NOTED. 5. SEE ARCH PLANS FOR EXACT BUILDING DIMENSIONS, LOCATIONS OF DOORS, AND BUILDING LIGHTING LOCATIONS. NOTES FEMA FLOOD ZONE "X" FEMA FLOOD ZONE "AE" FEMA FLOOD ZONE "X" EXISTING FIRE HYDRANT APPROXIMATELY ~145' TO SOUTH 0 SCALE: 1"=10' 5 10 20 EXISTING CONDITIONS AND DEMOLITION PLAN THE GREEN SOLUTION 810 N COLLEGE AVENUE FORT COLLINS, CO TGSFCCO01  2/2/2016 STF JAR DJM Plotted: 2/2/2016 12:31 PM Dwg Name: P:\Tgsfcco01\dwg\Eng\Final Drawings\Plan Set\Existing Conditions.dwg Updated By: lmoran ~145' TO FIRE HYDRANT PROJ. MGR.: DRAWN BY: DATE: OF SHEET PROJ. ASSOC.: DATE REVISIONS DRAWN BY c 2016 MANHARD CONSULTING, LTD. ALL RIGHTS RESERVED TM 1 12/15/15 1ST SUBMITTAL TO CITY JAR EXISTING ASPHALT PAVEMENT TO BE REMOVED EXISTING CONCRETE PAVEMENT TO BE REMOVED MILL AND OVERLAY EXISTING ASPHALT PAVEMENT 1. CONTRACTOR SHALL COORDINATE ALL UTILITY REMOVALS AND RELOCATIONS WITH CORRESPONDING UTILITY COMPANY. 2. EXISTING TOPOGRAPHY SHOWN REPRESENTS SITE CONDITIONS AS PREPARED BY MANHARD CONSULTING ON SEPTEMBER 23, 2015. CONTRACTOR SHALL FIELD CHECK EXISTING ELEVATIONS AND CONDITIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. 3. THE UNDERGROUND UTILITY INFORMATION SHOWN HEREON IS BASED, IN PART, UPON INFORMATION FURNISHED BY UTILITY COMPANIES AND THE LOCAL MUNICIPALITY. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, ITS ACCURACY AND COMPLETENESS CANNOT BE GUARANTEED NOR CERTIFIED TO. NOTES 12. THE DEVELOPER SHALL SEQUENCE INSTALLATION OF UTILITIES IN SUCH A MANNER AS TO MINIMIZE POTENTIAL UTILITY CONFLICTS. IN GENERAL, STORM SEWER AND SANITARY SEWER SHOULD BE CONSTRUCTED PRIOR TO INSTALLATION OF THE WATER LINES AND DRY UTILITIES. 13. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 14. A STATE CONSTRUCTION DEWATERING WASTEWATER DISCHARGE PERMIT IS REQUIRED IF DEWATERING IS REQUIRED IN ORDER TO INSTALL UTILITIES OR WATER IS DISCHARGED INTO A STORM SEWER, CHANNEL, IRRIGATION DITCH OR ANY WATERS OF THE UNITED STATES. 15. THE DEVELOPER SHALL COMPLY WITH ALL TERMS AND CONDITIONS OF THE COLORADO PERMIT FOR STORM WATER DISCHARGE (CONTACT COLORADO DEPARTMENT OF HEALTH, WATER QUALITY CONTROL DIVISION, (303) 692-3590), THE STORM WATER MANAGEMENT PLAN, AND THE EROSION CONTROL PLAN. 16. THE LOCAL ENTITY SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S). 17. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE LOCAL ENTITY, CERTIFICATION OF THE DRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BE SUBMITTED TO AND APPROVED BY THE STORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT. 18. THE LOCAL ENTITY SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES OR INJURIES SUSTAINED IN THIS DEVELOPMENT AS A RESULT OF GROUNDWATER SEEPAGE, WHETHER RESULTING FROM GROUNDWATER FLOODING, STRUCTURAL DAMAGE OR OTHER DAMAGE UNLESS SUCH DAMAGE OR INJURIES ARE SUSTAINED AS A RESULT OF THE LOCAL ENTITY FAILURE TO PROPERLY MAINTAIN ITS WATER, WASTEWATER, AND/OR STORM DRAINAGE FACILITIES IN THE DEVELOPMENT. 19. ALL RECOMMENDATIONS OF THE FINAL DRAINAGE AND EROSION CONTROL STUDY (NAME OF THE STUDY AND DATE) BY (ENGINEERING FIRM) SHALL BE FOLLOWED AND IMPLEMENTED. 20. TEMPORARY EROSION CONTROL DURING CONSTRUCTION SHALL BE PROVIDED AS SHOWN ON THE EROSION CONTROL PLAN. ALL EROSION CONTROL MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE DEVELOPER, UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS IS STABILIZED WITH HARD SURFACE OR LANDSCAPING. 21. THE DEVELOPER SHALL BE RESPONSIBLE FOR INSURING THAT NO MUD OR DEBRIS SHALL BE TRACKED ONTO THE EXISTING PUBLIC STREET SYSTEM. MUD AND DEBRIS MUST BE REMOVED WITHIN 24 HOURS BY AN APPROPRIATE MECHANICAL METHOD (I.E. MACHINE BROOM SWEEP, LIGHT DUTY FRONT-END LOADER, ETC.) OR AS APPROVED BY THE LOCAL ENTITY STREET INSPECTOR. 22. NO WORK MAY COMMENCE WITHIN ANY IMPROVED OR UNIMPROVED PUBLIC RIGHT-OF-WAY UNTIL A RIGHT-OF-WAY PERMIT OR DEVELOPMENT CONSTRUCTION PERMIT IS OBTAINED, IF APPLICABLE. 23. THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FOR ALL APPLICABLE AGENCIES PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DEVELOPER SHALL NOTIFY THE LOCAL ENTITY ENGINEERING INSPECTOR (FORT COLLINS - 221-6605) AND THE LOCAL ENTITY EROSION CONTROL INSPECTOR (FORT COLLINS ±221-6700) AT LEAST 2 WORKING DAYS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY, OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS. IF THE LOCAL ENTITY ENGINEER IS NOT AVAILABLE AFTER PROPER NOTICE OF CONSTRUCTION ACTIVITY AS BEEN PROVIDED, THE DEVELOPER MAY COMMENCE WORK IN THE ENGINEER ABSENCE. HOWEVER, THE LOCAL ENTITY RESERVES THE RIGHT NOT TO ACCEPT THE IMPROVEMENT IF SUBSEQUENT TESTING REVEALS AN IMPROPER INSTALLATION. 24. THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING SOILS TESTS WITHIN THE PUBLIC RIGHTOF-WAY AFTER RIGHT OF WAY GRADING AND ALL UTILITY TRENCH WORK IS COMPLETE AND PRIOR TO THE PLACEMENT OF CURB, GUTTER, SIDEWALK AND PAVEMENT. IF THE FINAL SOILS/PAVEMENT DESIGN REPORT DOES NOT CORRESPOND WITH THE RESULTS OF THE ORIGINAL GEOTECHNICAL REPORT, THE DEVELOPER SHALL BE RESPONSIBLE FOR A RE-DESIGN OF THE SUBJECT PAVEMENT SECTION OR, THE DEVELOPER MAY USE THE LOCAL ENTITY¶S DEFAULT PAVEMENT THICKNESS SECTION(S). REGARDLESS OF THE OPTION USED, ALL FINAL SOILS/PAVEMENT DESIGN REPORTS SHALL BE PREPARED BY A LICENSED PROFESSIONAL ENGINEER. THE FINAL REPORT SHALL BE SUBMITTED TO THE INSPECTOR A MINIMUM OF 10 WORKING DAYS PRIOR TO PLACEMENT OF BASE AND ASPHALT. PLACEMENT OF CURB, GUTTER, SIDEWALK, BASE AND ASPHALT SHALL NOT OCCUR UNTIL THE LOCAL ENTITY ENGINEER APPROVES THE FINAL REPORT. 25. THE CONTRACTOR SHALL HIRE A LICENSED ENGINEER OR LAND SURVEYOR TO SURVEY THE CONSTRUCTED ELEVATIONS OF THE STREET SUBGRADE AND THE GUTTER FLOWLINE AT ALL INTERSECTIONS,INLETS, AND OTHER LOCATIONS REQUESTED BY THE LOCAL ENTITY INSPECTOR. THE ENGINEER OR SURVEYOR MUST CERTIFY IN A LETTER TO THE LOCAL ENTITY THAT THESE ELEVATIONS CONFORM TO THE APPROVED PLANS AND SPECIFICATIONS. ANY DEVIATIONS SHALL BE NOTED IN THE LETTER AND THEN RESOLVED WITH THE LOCAL ENTITY BEFORE INSTALLATION OF BASE COURSE OR ASPHALT WILL BE ALLOWED ON THE STREETS. 26. ALL UTILITY INSTALLATIONS WITHIN OR ACROSS THE ROADBED OF NEW RESIDENTIAL ROADS MUST BE COMPLETED PRIOR TO THE FINAL STAGES OF ROAD CONSTRUCTION. FOR THE PURPOSES OF THESE STANDARDS, ANY WORK EXCEPT C/G ABOVE THE SUBGRADE IS CONSIDERED FINAL STAGE WORK. ALL SERVICE LINES MUST BE STUBBED TO THE PROPERTY LINES AND MARKED SO AS TO REDUCE THE EXCAVATION NECESSARY FOR BUILDING CONNECTIONS. 27. PORTIONS OF LARIMER COUNTY ARE WITHIN OVERLAY DISTRICTS. THE LARIMER COUNTY FLOODPLAIN RESOLUTION SHOULD BE REFERRED TO FOR ADDITIONAL CRITERIA FOR ROADS WITHIN THESE DISTRICTS. 28. ALL ROAD CONSTRUCTION IN AREAS DESIGNATED AS WILD FIRE HAZARD AREAS SHALL BE DONE IN ACCORDANCE WITH THE CONSTRUCTION CRITERIA AS ESTABLISHED IN THE WILD FIRE HAZARD AREA MITIGATION REGULATIONS IN FORCE AT THE TIME OF FINAL PLAT APPROVAL. 29. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION, THE CONTRACTOR SHALL CONTACT THE LOCAL ENTITY FORESTER TO SCHEDULE A SITE INSPECTION FOR ANY TREE REMOVAL REQUIRING A PERMIT. 30. THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO, EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY. REFER TO OSHA PUBLICATION 2226, EXCAVATING AND TRENCHING. 31. THE DEVELOPER SHALL SUBMIT A CONSTRUCTION TRAFFIC CONTROL PLAN, IN ACCORDANCE WITH MUTCD, TO THE APPROPRIATE RIGHT-OF-WAY AUTHORITY. (LOCAL ENTITY, COUNTY OR STATE), FOR APPROVAL, PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN, OR AFFECTING, THE RIGHT-OF-WAY. THE DEVELOPER SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY THE CONSTRUCTION ACTIVITIES. 32. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION THAT WILL AFFECT TRAFFIC SIGNS OF ANY TYPE, THE CONTRACTOR SHALL CONTACT LOCAL ENTITY TRAFFIC OPERATIONS DEPARTMENT, WHO WILL TEMPORARILY REMOVE OR RELOCATE THE SIGN AT NO COST TO THE CONTRACTOR; HOWEVER, IF THE CONTRACTOR MOVES THE TRAFFIC SIGN THEN THE CONTRACTOR WILL BE CHARGED FOR THE LABOR, MATERIALS AND EQUIPMENT TO REINSTALL THE SIGN AS NEEDED. 33. THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR THE INITIAL INSTALLATION OF TRAFFIC SIGNING AND STRIPING FOR THE DEVELOPMENT RELATED TO THE DEVELOPMENT¶S LOCAL STREET OPERATIONS. IN ADDITION, THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR TRAFFIC SIGNING AND STRIPING RELATED TO DIRECTING TRAFFIC ACCESS TO AND FROM THE DEVELOPMENT. 34. THERE SHALL BE NO SITE CONSTRUCTION ACTIVITIES ON SATURDAYS, UNLESS SPECIFICALLY APPROVED BY THE LOCAL ENTITY ENGINEER, AND NO SITE CONSTRUCTION ACTIVITIES ON SUNDAYS OR HOLIDAYS, UNLESS THERE IS PRIOR WRITTEN APPROVAL BY THE LOCAL ENTITY. 35. THE DEVELOPER IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS, SHOWN ON THESE DRAWINGS, OR DESIGNATED TO BE PROVIDED, INSTALLED, OR CONSTRUCTED, UNLESS SPECIFICALLY NOTED OTHERWISE. 36. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. IF PERTINENT DIMENSIONS ARE NOT SHOWN, CONTACT THE DESIGNER FOR CLARIFICATION, AND ANNOTATE THE DIMENSION ON THE AS-BUILT RECORD DRAWINGS. 37. THE DEVELOPER SHALL HAVE, ONSITE AT ALL TIMES, ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB. 38. IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE DEVELOPER SHALL CONTACT THE DESIGNER AND THE LOCAL ENTITY ENGINEER IMMEDIATELY. 39. THE DEVELOPER SHALL BE RESPONSIBLE FOR RECORDING AS-BUILT INFORMATION ON A SET OF RECORD DRAWINGS KEPT ON THE CONSTRUCTION SITE, AND AVAILABLE TO THE LOCAL ENTITY¶S INSPECTOR AT ALL TIMES. UPON COMPLETION OF THE WORK, THE CONTRACTOR(S) SHALL SUBMIT RECORD DRAWINGS TO THE LOCAL ENTITY ENGINEER. 40. THE DESIGNER SHALL PROVIDE, IN THIS LOCATION ON THE PLAN, THE LOCATION AND DESCRIPTION OF THE NEAREST SURVEY BENCHMARKS (2) FOR THE PROJECT AS WELL AS THE BASIS OF BEARINGS. THE INFORMATION SHALL BE AS FOLLOWS: BENCHMARKS²LOCAL ENTITY SURVEY. B.M.NUMBER___________________,ELEV.=_____________________, DESCRIPTION_______________________________________________. 41. ALL STATIONING IS BASED ON CENTERLINE/FLOWLINE (INSERT PROPER WORD) OF ROADWAYS UNLESS OTHERWISE NOTED. 42. DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS EXISTING FENCES, TREES, STREETS, SIDEWALKS, CURBS AND GUTTERS, LANDSCAPING, STRUCTURES, AND IMPROVEMENTS DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED IN LIKE KIND AT THE DEVELOPER¶S EXPENSE, UNLESS OTHERWISE INDICATED ON THESE PLANS, PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 43. WHEN AN EXISTING ASPHALT STREET MUST BE CUT, THE STREET MUST BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ITS ORIGINAL CONDITION. THE EXISTING STREET CONDITION SHALL BE DOCUMENTED BY THE LOCAL ENTITY CONSTRUCTION INSPECTOR BEFORE ANY CUTS ARE MADE. PATCHING SHALL BE DONE IN ACCORDANCE WITH THE LOCAL ENTITY STREET REPAIR STANDARDS. THE FINISHED PATCH SHALL BLEND IN SMOOTHLY INTO THE EXISTING SURFACE. ALL LARGE PATCHES SHALL BE PAVED WITH AN ASPHALT LAY-DOWN MACHINE. IN STREETS WHERE MORE THAN ONE CUT IS MADE, AN OVERLAY OF THE ENTIRE STREET WIDTH, INCLUDING THE PATCHED AREA, MAY BE REQUIRED. THE DETERMINATION OF NEED FOR A COMPLETE OVERLAY SHALL BE MADE BY THE LOCAL ENTITY ENGINEER AND/OR THE LOCAL ENTITY INSPECTOR AT THE TIME THE CUTS ARE MADE. 44. UPON COMPLETION OF CONSTRUCTION, THE SITE SHALL BE CLEANED AND RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED BEFORE CONSTRUCTION, OR TO THE GRADES AND CONDITION AS REQUIRED BY THESE PLANS. 45. STANDARD HANDICAP RAMPS ARE TO BE CONSTRUCTED AT ALL CURB RETURNS AND AT ALL ³T´INTERSECTIONS. 46. AFTER ACCEPTANCE BY THE LOCAL ENTITY, PUBLIC IMPROVEMENTS DEPICTED IN THESE PLANS SHALL BE GUARANTEED TO BE FREE FROM MATERIAL AND WORKMANSHIP DEFECTS FOR A MINIMUM PERIOD OF TWO YEARS FROM THE DATE OF ACCEPTANCE. 47. THE LOCAL ENTITY SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF ROADWAY AND APPURTENANT IMPROVEMENTS, INCLUDING STORM DRAINAGE STRUCTURES AND PIPES, FOR THE FOLLOWING PRIVATE STREETS: (LIST). 48. APPROVED VARIANCES ARE LISTED AS FOLLOWS: (PLAN SET MUST HAVE A LIST OF ALL APPLICABLE VARIANCES FOR THE PROJECT). ENGINEER NOTES 1. CONTRACTOR SHALL OBTAIN ALL APPLICABLE CODES, LICENSES, STANDARDS, SPECIFICATIONS, PERMITS, BONDS WHICH ARE NECESSARY TO PERFORM THE PROPOSED WORK. 2. ALL CONSTRUCTION IN THE CITY RIGHT-OF-WAY SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT. 3. TRAFFIC AND PEDESTRIAN CONTROL SHALL COMPLY WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) (LATEST EDITION). 4. ALL TRENCHES SHALL BE ADEQUATELY SUPPORTED AND THE SAFETY OF WORKERS PROVIDED FOR AS REQUIRED BY THE MOST RECENT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) "SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION." THESE REGULATIONS ARE DESCRIBED IN SUBPART P, PART 1926 OF THE CODE OF FEDERAL REGULATIONS. SHEETING AND SHORING SHALL BE UTILIZED WHERE NECESSARY TO PREVENT ANY EXCESSIVE WIDENING OR SLOUGHING OF THE TRENCH WHICH MAY BE DETRIMENTAL TO HUMAN SAFETY, TO THE PIPE BEING PLACED, TO TREES OR TO ANY EXISTING STRUCTURE WHERE EXCAVATIONS ARE MADE UNDER SEVERE WATER CONDITIONS. THE CONTRACTOR MAY BE REQUIRED TO USE AN APPROVED PILING INSTEAD OF SHEETING AND SHORING. 5. THE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTING AND MAINTAINING EROSION AND SEDIMENT CONTROL MEASURES AT ALL TIMES DURING CONSTRUCTION. THE PLAN MAY BE MODIFIED WITH APPROPRIATE APPROVALS FROM THE CITY'S ENGINEERING DIVISION AS FIELD CONDITIONS WARRANT. 6. REPAIR OF ANY DAMAGE TO EXISTING IMPROVEMENTS OR LANDSCAPING IS THE RESPONSIBILITY OF THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 7. ALL CONSTRUCTION ACTIVITIES MUST COMPLY WITH THE STATE OF COLORADO PERMITTING PROCESS FOR "STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY." FOR INFORMATION, PLEASE CONTACT COLORADO DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT, WATER QUALITY CONTROL DIVISION, WQCD-P-B2, 4300 CHERRY CREEK DRIVE SOUTH, DENVER, COLORADO 80246-1530. ATTENTION: PERMITS UNIT. PHONE (303) 692-3590. 8. THE TYPE, SIZE, LOCATION AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR UNKNOWN UNDERGROUND UTILITIES. 9. THE CONTRACTOR SHALL REGULARLY PATROL THE PUBLIC LANDS ADJACENT TO THE DEVELOPMENT, REMOVE CONSTRUCTION DEBRIS AND KEEP CLEAN AND SAFE. 10. IN CASE OF CONFLICTS WITHIN DRAWINGS AND SPECS, THE MOST STRINGENT REQUIREMENTS, AS DETERMINED BY THE ENGINEER, SHALL GOVERN. STANDARD NOTES PROPOSED FDC EXISTING OVERHEAD ELECTRIC PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED SIGN EXISTING SIGN PARKING COUNT SYMBOL ADJ ADJUST ARCH ARCHITECT BOP BOTTOM OF PIPE B/W BACK OF WALK BM BENCHMARK B/O BY OTHERS BW BOTTOM OF WALL CB CATCH BASIN CL CENTERLINE C.O.F. CITY OF FORT COLLINS CONC CONCRETE CY CUBIC YARD DIA DIAMETER DIP DUCTILE IRON PIPE E ELECTRIC ELEV ELEVATION EP EDGE OF PAVEMENT ESMT EASEMENT EX EXISTING FDC FIRE DEPARTMENT CONNECTION FG FINISHED GRADE FF FINISHED FLOOR FFE FINISH FLOOR ELEVATION FES FLARED END SECTION FL FLOW LINE/ FIRE LANE G GROUND G/F GRADE AT FOUNDATION G/S GARAGE SLAB GW GUY WIRE HP HIGH POINT HYD HYDRANT INL INLET INV INVERT LP LOW POINT ME MATCH EXISTING MAX MAXIMUM MH MANHOLE MIN MINIMUM PA PUBLIC ACCESS PL PROPERTY LINE PP POWER POLE PROP PROPOSED PVC POLYVINYL CHLORIDE PIPE P PAVEMENT R RADIUS ROW RIGHT-OF-WAY RCP REINFORCED CONCRETE PIPE SAN SANITARY SEWER SF SQUARE FOOT SMH SANITARY MANHOLE ST STORM SEWER SW SIDEWALK SY SQUARE YARDS TB THRUST BLOCK TBR TO BE REMOVED T TELEPHONE TC TOP OF CURB TF TOP OF FOUNDATION TOP TOP OF PIPE TW TOP OF WALL TEMP TEMPORARY U UTILITY WM WATER MAIN WSE WATER SURFACE ELEVATION LEGEND ABBREVIATIONS M THE GROW SHOP, LLC PO BOX 1428 FORT COLLINS, CO 80522 CONTACT: JOE DICE MANHARD CONSULTING LTD 8008 EAST ARAPAHOE COURT SUITE 110 CENTENNIAL, CO 80112 CONTACT: DANIEL MADRUGA PE ENGINEER: OWNER/DEVELOPER: SICKBERT & ASSOCIATES 5375 PENNSYLVANIA AVENUE BOULDER, CO 80303 CONTACT: MIKE SICKBERT ARCHITECT: FLOOD PLAIN ENGINEER HIGH POINT ENGINEERING PO BOX 150894 LAKEWOOD, CO 802015 CONTACT: JOHN TOMPKINS LANDSCAPE ARCHITECT NATURE'S DESIGN ASSOCIATES, LLC 15674 INDIANA GULCH ROAD JAMESTOWN, CO 80455 CONTACT: BECKY MARTINEK APPLICANT/TENANT THE GREEN SOLUTION, LLC 700 17TH STREET, SUITE 2200 DENVER, CO 80202 CONTACT: KYLE SPEIDELL OWNER'S ACKNOWLEDGMENT THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. OWNER (SIGNED) DATE THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS ________ DAY OF _____________ 20_____ A.D. BY (PRINT NAME) AS ____________________________________ MY COMMISSION EXPIRES:_______________ WITNESS MY HAND AND OFFICAL SEAL. NOTARY PUBLIC ADDRESS I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGN, REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS. THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF THE ITEMS ON THE PLANS AR THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. SHEET LIST TABLE SHEET NUMBER SHEET TITLE 01 COVER SHEET 02 GENERAL NOTES 03 EXISTING CONDITIONS AND DEMOLITION PLAN 04 SITE PLAN 05 GRADING AND DRAINAGE PLAN 06 OVERALL UTILITY PLAN 07 STORM PLAN & PROFILE A 08 STORM PLAN & PROFILE B 09 EROSION & SEDIMENT CONTROL PLAN 10 EROSION CONTROL DETAILS - 1 11 EROSION CONTROL DETAILS - 2 12 CONSTRUCTION DETAILS 13 CONSTRUCTION DETAILS 14 CONSTRUCTION DETAILS DANIEL J. MADRUGA REGISTERED PROFESSIONAL ENGINEER STATE OF COLORADO NO. 36834 MANHARD CONSULTING 8008 EAST ARAPAHOE COURT CENTENNIAL, CO. 80112 (303) 531-3400 UTILITY PLANS FOR THE GREEN SOLUTION 810 N COLLEGE AVE LOT 1, TGS COLLEGE AVENUE SUBDIVISION A PART OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS AND COUNTY OF LARIMER, STATE OF COLORADO PROJECT DATUM: NAVD88 SOURCE BENCHMARKS: 1. CITY OF FORT COLLINS BM 1-00 2" ALUMINUM CAP ON A CATCH BASIN AT THE SOUTHEAST CORNER OF VINE DRIVE AND COLLEGE AVENUE. ELEVATION = 4968.74 (NAVD 88) 2. CITY OF FORT COLLINS BENCHMARK 43-97 2" ALUMINUM CAP LOCATED ON THE SOUTH END OF THE WEST HEADWALL OF THE LAKE CANAL BRIDGE AT NORTH LEMAY AVENUE, 200 FEET SOUTH OF THE INTERSECTION OF LEMAY AVENUE AND CONIFER STREET. ELEVATION = 4960.11 (NAVD 88) MEASURED ELEVATION = 4960.18 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED. NGVD29 = NAVD88 - 2.94'. BENCHMARKS