April 15, 2016
Perception Design Group Inc
6901 S Pierce St Suite 350
Littleton, CO 80128
RE: Fort Collins Emergency Center - 4858 S College Ave, PDP160001, Round Number 2
Comment Summary:
Department: Planning Services
Contact: Ryan Mounce, 970-224-6186, rmounce@fcgov.com
Topic: General
04/08/2016: Is there a corresponding access easement north of the property
boundary? A full 24 foot access easement (two-way drive aisle width) is needed to
access the parking stalls north of the building.
Comment Number: 12 Comment Originated: 04/08/2016
04/08/2016: At the staff review meeting, potential ideas for the drop-off area were
discussed to help direct or restrict flow and avoid confusion. Please identify what
kind of devices (signs, striping, etc) will be used on the site plan.
Comment Number: 13 Comment Originated: 04/08/2016
04/08/2016: Will/where are the location of exterior utility meters? If unknown at this
time, please add the following note on the site plan: Conduits, meters, vents, and
other equipment attached to the building or protruding from the roof shall be painted
to match surrounding building surfaces.
Comment Number: 14 Comment Originated: 04/08/2016
04/08/2016: Please specify or list potential colors for the building materials for
evaluation. Are color or materials samples available for review?
Colors should be selected based on existing surrounding development, drawing
from neutral and earth-toned ranges.
Comment Number: 15 Comment Originated: 04/08/2016
Department: Engineering Development Review
Contact: Katie Sexton, 970-221-6501, ksexton@fcgov.com
Topic: General
Please see the following summary of comments from City staff and outside reviewing agencies for
your submittal of the above referenced project. If you have questions about any comments, you may
contact the individual commenter or direct your questions through the Project Planner, Ryan Mounce, at
970-224-6186 or rmounce@fcgov.com.
Page 1 of 9
03/31/2016: Engineering is ready for the project to go to hearing, final details will be
reviewed at FDP submittal.
Comment Number: 6 Comment Originated: 03/31/2016
Department: Environmental Planning
Contact: Rebecca Everette, 970-416-2625, reverette@fcgov.com
Topic: General
04/08/2016: Thank you for the revisions to the detention pond area, including the
grading and additional shrubs along the western edge. The new design looks nice.
Comment Number: 6 Comment Originated: 04/08/2016
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com
Topic: Landscape Plans
04/15/2016:
There are two trees that appear not to be labeled. The shade tree SW corner of the
building and the shade tree near the NW corner of the building. Please label.
Comment Number: 6 Comment Originated: 04/15/2016
04/15/2016:
Three Northern Red oaks Quercus rubra are used on the plans. This oak species is
not adapted to the alkaline soils found in Fort Collins. Shumrad Oak is very similar
and is compatible with Fort Collins soils. Change the Northern Red oak to Shumard
Oak or to another adapted shade tree.
Comment Number: 7 Comment Originated: 04/15/2016
Department: Internal Services
Contact: Russell Hovland, 970-416-2341, rhovland@fcgov.com
Topic: Building Insp Plan Review
Page 2 of 9
01/27/2016:
Building Permit Pre-Submittal Meeting:
Pre-Submittal meetings are required to assist the designer/builder by assuring, early
on in the design,
that the new commercial or multi-family projects are on track to complying with all of
the adopted City
codes and Standards listed below. The proposed project should be in the early to
mid-design stage for
this meeting to be effective and is typically scheduled after the Current Planning
conceptual review
meeting. Applicants of new commercial or multi-family projects are advised to call
416-2341 to schedule
a pre-submittal meeting. Applicants should be prepared to present site plans, floor
plans, and elevations
and be able to discuss code issues of occupancy, square footage and type of
construction being proposed.
Construction shall comply with the following adopted codes as amended:
2012 International Building Code (IBC)
2012 International Residential Code (IRC)
2012 International Energy Conservation Code (IECC)
2012 International Mechanical Code (IMC)
2012 International Fuel Gas Code (IFGC)
2012 International Plumbing Code (IPC) as amended by the State of Colorado
2014 National Electrical Code (NEC) as amended by the State of Colorado
Fort Collins has amendments to most of the codes listed above. See the fcgov.com
web page to view them.
Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009.
Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load: 100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5
Energy Code Use
1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC.
2. Multi-family and Condominiums 3 stories max: 2012 IECC residential chapter.
3. Commercial and Multi-family 4 stories and taller: 2012 IECC commercial chapter.
Project specific concerns:
1. Upgraded insulation is required for buildings using electric heat or cooling.
2. Low-flow Watersense plumbing fixtures (toilet, faucets, shower heads) are
required.
3. Special combustion safety requirements for natural draft gas appliances.
4. Low VOC interior finishes.
City of Fort Collins
Building Services
Plan Review
416-2341
Comment Number: 1 Comment Originated: 01/27/2016
Department: Light And Power
Contact: Coy Althoff, , CAlthoff@fcgov.com
Topic: General
Page 3 of 9
01/18/2016: 3-Phase Primary electric facilities exists along the East side of this
property.
Comment Number: 1 Comment Originated: 01/18/2016
01/18/2016: Please provide a one line diagram and a C-1 form to Light and Power
Engineering. The C-1 form can be found at:
http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1Form.pdf
Comment Number: 3 Comment Originated: 01/18/2016
01/18/2016: Development charges, electric Capacity Fee, Building Site charges
and any system modification charges necessary will apply to this development.
(We urge you to use our fee estimator to help better understand these charges.)
http://www.fcgov.com/utilities/business/builders-and-developers
Comment Number: 4 Comment Originated: 01/18/2016
01/18/2016: Please contact Light & Power Engineering if you have any questions at
221-6700. Please reference our policies, development charge processes, and use
our fee estimator at
http://www.fcgov.com/utilities/business/builders-and-developers.
Comment Number: 6 Comment Originated: 01/18/2016
04/11/2016: Comments 2 & 5 resolved. Nothing additional on behalf of Light &
Power at this time.
Comment Number: 7 Comment Originated: 04/11/2016
Department: Outside Agencies
Contact: Ryan Mounce, 970-224-6186, rmounce@fcgov.com
Topic: General
04/04/2016: The following comments are from the Megan Harrity, Larimer County
Assessor, 970-498-7065:
At the end of the second line of the legal description, please correct east line to west
line. Line reads:
;thence leaving said east line S 89' 22' 55'' etc
Comment Number: 2 Comment Originated: 04/04/2016
The following comment is from Terry Farrill, Fort Collins - Loveland Water District
and South Fort Collins Sanitation District. Terry may be reached at 970-226-3104,
ext. 104.
The fence cannot be located within the 20 foot wide access easement.
Comment Number: 3 Comment Originated: 04/07/2016
Department: Stormwater Engineering
Contact: Dan Mogen, 970-224-6192, dmogen@fcgov.com
Topic: General
04/13/2016: Comment still applies. Please see redlines in drainage report. The
detention volume calculation needs to be completed using FC Criteria.
01/26/2016: Please review City of Fort Collins Criteria and design detention basin
accordingly.
Comment Number: 2 Comment Originated: 01/26/2016
Page 4 of 9
04/13/2016: Please update once detention volume is revised.
01/26/2016: Please provide evidence that the detention basin is in compliance with
drain times per Colorado Revised Statute 37-92-602(8). More information on this
statute is available at http://tinyurl.com/RevisedStatuteMemo, and a spreadsheet to
show compliance is available for download at
http://tinyurl.com/ComplianceSpreadsheet. Please contact Dan Mogen at
(970)224-6192 or dmogen@fcgov.com with any questions about this requirement or
for assistance with the spreadsheet.
Comment Number: 3 Comment Originated: 01/26/2016
04/13/2016: Comment still applies. I see that there is a proposed easement for the
detention basin; however, it does not appear that the outfall pipe is included within
this easement (it needs to be) prior to entering the existing easement on the
property to the south. Coordination of the outfall construction with the property
owner to the south will be required. Is it possible that the outfall location could be
revised to daylight further north, possibly with some swale grading?
01/26/2016: Please show where the proposed outlet is located and verify capacity
and that any required easements are in place. Please clarify existing and any
proposed easements.
Comment Number: 4 Comment Originated: 01/26/2016
04/13/2016: Please include discussion within the drainage report along with table
describing how the LID requirements are being met.
01/26/2016: Please show areas being treated with LID techniques and verify that
LID requirements are being met. A table verifying this would be helpful and a
sample table can be downloaded at http://tinyurl.com/SampleLIDTable.
Comment Number: 5 Comment Originated: 01/26/2016
04/13/2016: Please provide a discussion of all drainage basins within the text of the
drainage report.
01/26/2016: Please include all site areas in basins including those that are not
currently shown to be detained on the west and south sides.
Comment Number: 6 Comment Originated: 01/26/2016
04/13/2016: Please see updated redlined report (provided in pdf format) and plans.
01/26/2016: Please see redlined drainage report and civil plans.
Comment Number: 8 Comment Originated: 01/26/2016
04/13/2016: Comment still applies.
01/26/2016: Please note that additional comments may be forthcoming upon future
submittals as additional details are discovered.
Comment Number: 9 Comment Originated: 01/26/2016
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
Topic: Erosion Control
Page 5 of 9
04/12/2016: Erosion Control Report is acceptable. The Erosion Control Plan has
redlines. The Erosion Control Escrow Calculation could not be found.
01/11/2016: The site disturbs more than 10,000 sq-ft, therefore Erosion and
Sediment Control Materials need to be submitted for FDP. The erosion control
requirements are in the Stormwater Design Criteria under the Amendments of
Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials Submitted do
not meet requirements. Please submit; Erosion Control Plan (based upon redline
comments), Erosion Control Report (a few minor redlines), and an Escrow /
Security Calculation (Not found with submitted materials template can be found at
www.fcgov.com/erosion . Also, based upon the area of disturbance State permits
for stormwater will be required since the site is over an acre. If you need clarification
concerning the erosion control section, or if there are any questions please contact
Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com
Comment Number: 1 Comment Originated: 01/11/2016
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Building Elevations
04/13/2016: Please revise the sub-title as marked. See redlines.
01/25/2016: Please revise the sub-title as marked. See redlines.
Comment Number: 9 Comment Originated: 01/25/2016
04/13/2016: There are line over text issues. See redlines.
01/25/2016: There are line over text issues. See redlines.
Comment Number: 10 Comment Originated: 01/25/2016
04/13/2016: Please add sheet numbering.
Comment Number: 38 Comment Originated: 04/13/2016
04/13/2016: There are cut off text issues. See redlines.
Comment Number: 39 Comment Originated: 04/13/2016
Topic: Construction Drawings
04/13/2016: Please revise the sub-title as marked. See redlines.
01/25/2016: Please revise the sub-title as marked. See redlines.
Comment Number: 14 Comment Originated: 01/25/2016
04/13/2016: The legal description on sheet C4.11 is not necessary. It needs to be
corrected or removed. See redlines.
01/25/2016: Please remove the legal description. It is not necessary. It is a
duplication of the sub-title.
Comment Number: 15 Comment Originated: 01/25/2016
Page 6 of 9
04/13/2016: Please add the NAVD88 elevation for the benchmark shown.
01/25/2016: The City has moved to the NAVD88 vertical datum, and as of January
1, 2015 all projects are required to be on NAVD88 datum. Please provide the
following information for the Benchmark Statement in the EXACT format shown
below.
PROJECT DATUM: NAVD88
BENCHMARK # w/ DESCRIPTION
ELEVATION:
BENCHMARK # w/ DESCRIPTION
ELEVATION:
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR
THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE
FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88
- X.XX¿.
Comment Number: 16 Comment Originated: 01/25/2016
04/13/2016: The titles in the sheet index do not match the titles on the noted sheets.
See redlines.
01/25/2016: The titles in the sheet index do not match the titles on the noted sheets.
See redlines.
Comment Number: 17 Comment Originated: 01/25/2016
04/13/2016: There are line over text issues. See redlines.
01/25/2016: There are line over text issues. See redlines.
Comment Number: 20 Comment Originated: 01/25/2016
04/13/2016: There is text that needs to be masked. Mask all text in hatched areas.
See redlines.
01/25/2016: There is text that needs to be masked. Mask all text in hatched areas.
See redlines.
Comment Number: 21 Comment Originated: 01/25/2016
04/13/2016: These are being dedicated on the Subdivision Plat, so why are they still
being dedicated by separate document?
01/26/2016: All reception numbers for documents recorded by separate document
must be added prior to mylars.
Comment Number: 23 Comment Originated: 01/26/2016
04/13/2016: This has not been corrected.
01/26/2016: Please correct the 10' Bridle Path & Utility Easement note as marked.
See redlines.
Comment Number: 24 Comment Originated: 01/26/2016
Topic: Landscape Plans
04/13/2016: Please revise the sub-title as marked. See redlines.
01/25/2016: Please revise the sub-title as marked. See redlines.
Comment Number: 7 Comment Originated: 01/25/2016
04/13/2016: There are line over text issues. See redlines.
01/25/2016: There are line over text issues. See redlines.
Comment Number: 8 Comment Originated: 01/25/2016
Page 7 of 9
04/13/2016: There is text that needs to be moved. See redlines.
Comment Number: 34 Comment Originated: 04/13/2016
04/13/2016: Please correct the sheet numbering. See redlines.
Comment Number: 35 Comment Originated: 04/13/2016
04/13/2016: There are text over text issues. See redlines.
Comment Number: 36 Comment Originated: 04/13/2016
04/13/2016: There are cut off text issues. See redlines.
Comment Number: 37 Comment Originated: 04/13/2016
Topic: Lighting Plan
04/13/2016: Please revise the sub-title as marked. See redlines.
01/25/2016: Please revise the sub-title as marked. See redlines.
Comment Number: 11 Comment Originated: 01/25/2016
Topic: Plat
04/13/2016: Please add a title at the top of the sheet. See redlines.
Comment Number: 25 Comment Originated: 04/13/2016
04/13/2016: Please change the subdivision name to "Fairway Estates Filing Four".
See redlines.
Comment Number: 26 Comment Originated: 04/13/2016
04/13/2016: Are there any Lienholders for this property? If so, please add a
signature block. If not, please add a note stating there are none, and include
response in written comments.
Comment Number: 27 Comment Originated: 04/13/2016
04/13/2016: Please remove note #3. This address could change. See redlines.
Comment Number: 28 Comment Originated: 04/13/2016
04/13/2016: Please add dedication information for all street rights of way. See
redlines.
Comment Number: 29 Comment Originated: 04/13/2016
04/13/2016: Please label the Point Of Beginning.
Comment Number: 30 Comment Originated: 04/13/2016
04/13/2016: What is the triangular area at the northwest corner of the plat? See
redlines.
Comment Number: 31 Comment Originated: 04/13/2016
04/13/2016: Please add record bearings & distances for the boundary. See
redlines.
Comment Number: 32 Comment Originated: 04/13/2016
04/13/2016: Please add distances as marked. See redlines.
Comment Number: 33 Comment Originated: 04/13/2016
Topic: Site Plan
04/13/2016: Please revise the sub-title as marked. See redlines.
01/25/2016: Please revise the sub-title as marked. See redlines.
Comment Number: 1 Comment Originated: 01/25/2016
Page 8 of 9
04/13/2016: This has not been corrected.
01/25/2016: Please remove the legal description. It is not necessary. It is a
duplication of the sub-title.
Comment Number: 2 Comment Originated: 01/25/2016
04/13/2016: These are being dedicated on the Subdivision Plat, so why are they still
being dedicated by separate document?
01/25/2016: All reception numbers for documents recorded by separate document
must be added prior to mylars.
Comment Number: 5 Comment Originated: 01/25/2016
04/13/2016: This has not been corrected.
01/25/2016: Please correct the 10' Bridle Path & Utility Easement note as marked.
See redlines.
Comment Number: 6 Comment Originated: 01/25/2016
Department: Traffic Operation
Contact: Martina Wilkinson, 970-221-6887, mwilkinson@fcgov.com
Topic: General
04/12/2016: ready for hearing
Comment Number: 4 Comment Originated: 04/12/2016
Department: Water Conservation
Contact: Eric Olson, 970-221-6704, eolson@fcgov.com
Topic: General
01/19/2016: A landscape plan shall contain accurate and identifiable hydrozones,
including a water budget chart that shows the total annual water use, which shall not
exceed fifteen (15) gallons per square foot over the site. If you have questions
contact Eric Olson at eolson@fcgov.com or 970-221-6704.
Comment Number: 1 Comment Originated: 01/19/2016
01/19/2016: Irrigation plans are required no later than at the time of building permit.
The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of
the Land Use Code. Direct questions concerning irrigation requirements to Eric
Olson, at 221-6704 or eolson@fcgov.com
Comment Number: 2 Comment Originated: 01/19/2016
Page 9 of 9