HomeMy WebLinkAboutTHE HUB ON CAMPUS - PDP - PDP160038 - SUBMITTAL DOCUMENTS - ROUND 3 - (5)B O S T O N B U F F A L O C H I C A G O C L E V E L A N D D E T R O I T N E W Y O R K T O R O N T O
32-14-13
Unilock Permeable 2015
For any additional information or assistance with this spec please contact your Unilock
Representative.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 1
*** Delete all text in RED after modifying the text in BLUE. All BLUE text
requires modification. ***
FOREWORD
These specifications have been prepared for the general guidance of architects, engineers, contractor
and superintendents associated with the construction of permeable interlocking concrete pavements.
Consult with a qualified engineer to determine the suitability of the design, confirm site conditions and
monitor the installation in critical applications.
INTRODUCTION
Unilock® permeable pavers are manufactured in a variety of shapes and colors for residential,
commercial, municipal and industrial applications. They offer design professionals several engineered
pavement systems that are efficient, durable, economical and aesthetically attractive.
Unilock® permeable pavers are manufactured to tight dimensional tolerances. This, in combination with
their permeable and interlocking capabilities, allows the surface to be completely porous with a high
resistance to compressive loads and lateral forces.
SECTION 32 14 13.19
PERMEABLE CONCRETE PAVER MATERIALS
PART 1 GENERAL
1.01 SUMMARY
A. Section includes the following:
1. Permeable Concrete Pavers
2. Permeable Joint Opening Aggregate
3. Permeable Joint Aggregate Type 1
4. Permeable Joint Aggregate Type 2
5. Permeable Setting Bed Aggregate (Open-graded)
6. Permeable Base Aggregate (Open-graded)
7. Permeable Subbase Aggregate (Open-graded)
1.02 REFERENCES
Note: Design street, industrial, port and airport pavement thicknesses in consultation with a
qualified civil engineer, in accordance with established flexible pavement design
procedures, LOCKPAVE® software, and in accordance with Interlocking Concrete
Pavement Institute Technical Bulletins. Sample construction detail drawings are available
from Unilock®. This specification may require modifications.
A. ASTM International, latest edition:
1. C 29 Bulk Density and Voids in Aggregate Materials.
2. C 33, Standard Specification for Concrete Aggregates.
3. C 67, Standard Test Methods for Sampling and Testing Brick and Structural Clay
Tile, Section 8, Freezing and Thawing.
4. C 136, Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates.
5. C 140, Standard Test Methods for Sampling and Testing Concrete Masonry Units
and Related Units.
6. C 144 Standard Specifications for Aggregate for Masonry Mortar.
7. D 448, Standard Classification for Sizes of Aggregate for Road and Bridge
Construction.
8. C 936, Standard Specification for Solid Concrete Interlocking Paving Units.
9. C 979, Standard Specification for Pigments for Integrally Colored Concrete.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 2
10. D 698 Test Methods for Moisture Density Relations of Soil and Soil Aggregate
Mixtures Using a 5.5 lb (24.4 N) Rammer and 12 in. (305 mm) drop.
11. D 1557 Test Methods for Moisture Density Relations of Soil and Soil Aggregate
Mixtures Using a 10-lb (44.5 N) Rammer and 18 in. (457 mm) drop.
12. C1645 Standard Test Method for Freeze-thaw and De-icing Salt Durability of Solid
Concrete Interlocking Paving Units
13. D 1883, Test Method for California Bearing Ratio of Laboratory-Compacted Soils.
14. D 2940 Graded Aggregate Material for Bases or Subbases for Highways or
Airports.
15. D 4254, Standard Test Methods for Minimum Index Density and Unit Weight of
Soils and Calculation of Relative Density.
16. D 5261, Standard Test Method for Measuring Mass per Unit Area of Geotextiles
17. D 4632, Standard Test Method for Grab Breaking Load and Elongation of
Geotextiles
18. D 4533, Standard Test Method for Index Trapezoidal Tearing Strength of
Geotextiles
19. D 4833, Standard Test Method for Index Puncture Resistance of Geotextiles,
Geomembranes and Related Products
20. D 4491, Standard Test Method for Water Permeability of Geotextiles by
Permittivity
21. D 4751, Standard Test Method for Determining Apparent Opening Size of a
Geotextile
22. D 4354, Standard Practice for Sampling of Geosynthetics for Testing
23. D 4759, Standard Practice for Determining the Specifications Conformance of
Geosynthetics
Delete the BLUE text above if no geotextile is being utilized.
Note: In order to determine the latest version of the listed specifications and standards,
please consult the ASTM web page (www.astm.com)
B. U.S. Green Building Council Leadership in Energy and Environmental Design (LEED)
1. Building Design + Construction, latest edition
1.03 SUBMITTALS
A. Permeable Concrete Pavers:
1. Samples for verification: Three representative full-size samples of each paver type,
thickness, color and finish that indicate the range of color variation and texture
expected upon project completion.
2. Accepted samples become the standard of acceptance for the product produced.
3. Test results from an independent testing laboratory for compliance of concrete
pavers with ASTM C 936.
4. Manufacturer’s catalog product data, installation instructions, and material safety
data sheets for the safe handling of the specified materials and products.
B. Permeable Joint Opening Aggregate:
1. Provide three representative one pound samples in containers of aggregate
materials that indicate the range of color variation and texture expected upon
project completion.
2. Accepted samples become the standard of acceptance for the product produced.
3. Test results from an independent testing laboratory for sieve analysis, including
washed gradations per ASTM C 136.
4. Test results for void space percentage per ASTM C 29.
C. Permeable Setting Bed, Base and Subbase Aggregate:
1. Test results from an independent testing laboratory for compliance with ASTM D
448 No. 8, No. 57 and No. 2.
2. Test results from an independent testing laboratory for sieve analysis, including
washed gradations per ASTM C 136.
3. Test results for void space percentage per ASTM C 29.
D. Paving Installation Contractor:
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 3
1. Job references from a minimum of three projects similar in size and complexity.
Provide Owner/Client/General Contractor names, postal address, phone, fax, and
email address.
E. LEED (required only for LEED projects, delete otherwise)
1. LEED Materials and Resources Credit 4, Recycled Materials: Submit letter from
manufacturer certifying the products having recycled content, documentation
indicating percentages by weight of post-consumer and pre-consumer recycled
content.
a. Include statement indicating costs for each product having recycled content.
2. LEED Materials and Resources Credit 5, Regional Materials: Submit letter from
manufacturer certifying products having been extracted, harvested, or recovered, as
well as manufactured within 500 miles of the project site.
a. Include a statement indicating the percentage by weight which is extracted,
harvested, or recovered within 500 miles of the project site.
3. LEED Sustainable Sites Credit 7.1, Non-roof: Submit letter from manufacturer
certifying the solar reflectance index (SRI) of the paver is 29 or greater.
1.04 QUALITY ASSURANCE
A. Utilize a Manufacturer having at least ten years of experience manufacturing interlocking
concrete pavers on projects of similar nature or project size.
B: Source Limitations:
1. Obtain Permeable Concrete Pavers from one source location with the resources to
provide products of consistent quality in appearance and physical properties.
2. Obtain Permeable Joint Opening Aggregate from one source with the resources to
provide materials and products of consistent quality in appearance and physical
properties.
C. Paving Contractor Qualifications:
1. Utilize an installer having successfully completed concrete paver installation similar
in design, material, and extent indicated on this project.
D. Mockups:
1. Install a 5 ft x 5 ft paver area.
2. Use this area to determine joint sizes, lines, laying pattern(s) and levelness. This
area will serve as the standard by which the workmanship will be judged.
3. Subject to acceptance by owner, mock-up may be retained as part of finished work.
4. If mock-up is not retained, haul offsite and dispose legally.
1.05 DELIVERY, STORAGE & HANDLING
A. In accordance with Conditions of the Contract and Division 1 Product Requirement
Section. (Modify this to match the general conditions of the specific project)
B. Deliver Permeable Concrete Pavers in manufacturer’s original, unopened and
undamaged container packaging with identification labels intact.
1. Coordinate delivery and paving schedule to minimize interference with normal use
of streets and sidewalks adjacent to paver installation.
2. Deliver concrete pavers to the site in steel banded, plastic banded or plastic
wrapped packaging capable of transfer by forklift or clamp lift.
3. Unload pavers at job site in such a manner that no damage occurs to the product
or adjacent surfaces.
C. Store and protect materials free from mud, dirt and other foreign materials.
1.06 PROJECT/SITE CONDITIONS
A. Environmental Requirements:
1. Install permeable pavers only on unfrozen permeable setting bed aggregate
materials.
2. Install permeable setting bed only on unfrozen permeable base and subbase
aggregates.
3. Install permeable base or subbase aggregates only over unfrozen subgrade.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 4
1.07 PERMEABLE CONCRETE PAVER OVERAGE AND ATTIC STOCK
A. Provide a minimum of 5% additional material for overage to be used during construction.
B. Furnish 100 square feet of each product and size used to owner for maintenance and
repair. Furnish Permeable Concrete Pavers from the same production run as installed
materials.
C. Manufacture to supply maintenance and reinstatement manuals for Permeable Concrete
Paver units.
1.08 LEED REQUIREMENTS (required only for LEED projects, delete otherwise)
A. Add any specific requirements necessary for achieving desired credits.
PART 2 PRODUCTS
2.01 PERMEABLE CONCRETE PAVERS
A. Basis-of-Design Product: The permeable concrete paver shapes are based on:
1. Unilock: (Select product or products being used)
a. Eco-Optiloc
b. Eco-Priora
c. Ecoloc
d. Eco-Stone
e. Town Hall
2. As manufactured by:
Unilock (Add location)
Address
City, State and Zip
Contact: (insert Unilock representative name and phone number) or your local
Territory Manager
3. The specified products establish minimum requirements that substitutions must
meet to be considered acceptable.
a. To obtain acceptance of unspecified products, submit written requests at least
7 days before the Bid Date.
Note: Unless required by the owner, an “or equal” line is not necessary when using a
basis-of-design specification with the above information is listed and outline in
Division 1, Product Substitution Procedures.
Or choose number 3 below and delete above number 3.
3. Substitutions: No substitutions permitted.
B. Product requirements:
1. Permeable Paver Type 1: Unilock Eco-Optiloc (or other Unilock product name)
a. Color: Insert product color
b. Finish: (Select finish type from below and insert here. Finish type will affect
product pricing).
1. Standard – this is not a face mix finish.
2. Smooth (Premier) – this is a face mix finish.
3. Brushed (IL Campo) – this is a face mix finish.
4. Exposed Granite (Series 3000) – this is a face mix finish.
5. Granite appearance (Umbriano) – this is a face mix finish.
6. Tile appearance (Belpasso) – this is a face mix finish.
7. TX Active photocatalytic cement – this is a face mix finish.
c. Edge: Chamfer - 3 mm bevel
d. Size: Manufacture the sizes indicated with a maximum tolerance of plus or
minus 1/16 in all directions.
1. L-shape
Note: Imperial dimensions are nominal equivalents to the metric dimensions.
2. Permeable Paver Type 2: Unilock Eco-Priora (or other Unilock product name)
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 5
a. Color: Insert product color
b. Finish: (Select finish type from below and insert here. Finish type will affect
product pricing).
1. Standard – this is not a face mix finish.
2. Smooth (Premier) – this is a face mix finish.
3. Brushed (IL Campo) – this is a face mix finish.
4. Exposed Granite (Series 3000) – this is a face mix finish.
5. Granite appearance (Umbriano) – this is a face mix finish.
6. Tile appearance (Belpasso) – this is a face mix finish.
7. TX Active photocatalytic cement – this is a face mix finish either Premier or
Brushed.
c. Edge: Chamfer - 3 mm rolled
d. Size: Manufacture the sizes indicated with a maximum tolerance of plus or
minus 1/16 in all directions.
1. 120 mm (5 in) x 120 mm (5 in) x 80 mm (3-1/8 in) thick
2. 120 mm (5 in) x 240 mm (10 in) x 80 mm (3-1/8 in) thick
3. 240 mm (10 in) x 240 mm (10 in) x 80 mm (3-1/8 in) thick
Note: Imperial dimensions are nominal equivalents to the metric dimensions.
3. Permeable Paver Type 3: Town Hall (or other Unilock product name)
a. Color: Insert product color(s): Burgundy Red, Burnt Clay, Old Oak
b. Finish: Streetpaver appearance
d. Size: Manufacture the sizes indicated with a maximum tolerance of plus or
minus 1/16 in all directions.
1. 10 cm (4 in) x 25 cm (9-3/4 in) x 7 cm (2-3/4 in) thick
4. (Insert additional Permeable Paver Types here as necessary or delete this line)
C. Provide pavers meeting the minimum material and physical properties set forth in ASTM
C 936, Standard Specification for Interlocking Concrete Paving Units. Efflorescence is not
a cause for rejection.
1. Average compressive strength 8000 psi (55MPa) with no individual unit under
7,200 psi (50 MPa).
2. Average absorption of 5% with no unit greater than 7% when tested according to
ASTM C 140.
3. Resistance to 50 freeze-thaw cycles, when tested according to ASTM C1645, with
no breakage greater than 1.0% loss in dry weight of any individual unit. Conduct
this test method not more than 12 months prior to delivery of units.
Note: Efflorescence is a whitish powder-like deposit that sometimes appears on
concrete products. Calcium hydroxide and other water-soluble materials form or are
present during the hydration of Portland cement. Pore water becomes saturated with
these materials, and diffuses to the surface of the concrete. When this water evaporates,
the soluble materials remain as a whitish deposit on the concrete surface. The calcium
hydroxide is converted to calcium carbonate during a reaction with carbon dioxide from
the atmosphere. The calcium carbonate is difficult to remove with water. However, the
efflorescence will wear off with time, and it is advisable to wait a few months before
attempting to remove any efflorescence. Commercially available cleaners can be used,
provided directions are carefully followed. Some cleaners contain acids that may alter the
color of the pavers.
D. Accept only pigments in concrete pavers conforming to ASTM C 979.
Note: ACI Report No. 212.3R provides guidance on the use of pigments.
E. Maximum allowable breakage of product is 5%.
F. TX Active is a Portland Cement (white) Type I, II, and III complying with ASTM C 150 with
the addition of proprietary particles of titanium dioxide (TiO2) specifically engineered for
use in the manufacture of concrete and concrete products.
1. TX Active - Self-cleaning and pollution reduction
• Concrete will resist most organic and inorganic pollutants that gather on the
surface causing discoloration.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 6
• Concrete will remove significant amounts of environmental pollutants deemed
harmful to human health.
2. As manufactured by ESSROC Italcementi Group.
a. Unilock Chicago is an authorized producer of TX Active products.
NOTE: CONTACT YOUR LOCAL UNILOCK COMMERCIAL PRODUCT
REPRESENTATIVE PRIOR TO SPECIFYING TX ACTIVE CEMENT.
2.02 PERMEABLE JOINT OPENING AGGREGATE
A. Provide Permeable Joint Opening Aggregate materials conforming to ASTM C 33 and
gradation requirements of ASTM D 448 No. 8 as shown in Table 1. Unilock recommends
using granite chips listed in table 2 below for vehicular areas with heavy traffic loads such
as roadways or drive-through areas.
TABLE 1 - ECO-OPTILOC
PERMEABLE JOINT OPENING AGGREGATE
GRADATION REQUIREMENTS
(CRUSHED LIMESTONE)
ASTM No. 8
Sieve Size Percent Passing
1/2 in (12.5 mm) 100
3/8 in (9.5 mm) 85 to 100
No. 4 (4.75 mm) 10 to 30
No. 8 (2.36 mm) 0 to 10
No. 16 (1.18 mm) 0 to 5
B. Provide Permeable Joint Opening Aggregate materials conforming to ASTM C 33 and
gradation requirements as presented in Table 2.
1. Supplier:
a. Kafka Granite LLC, 101 S. Weber Ave, Stratford, WI 54484 –
Toll Free: 800-852-7415
b. Alliance Aqua-Roc
c. SEK Perm Chip
2. Color: (Specify granite chip color if other than crushed limestone)
TABLE 2 - ECO-PRIORA & TOWN HALL
PERMEABLE JOINT OPENING AGGREGATE
GRADATION REQUIREMENTS
(GRANITE CHIPS)
1/8 to 3/16 inch granite chips
Sieve Size Percent Passing
1/4 in (6 mm) 97 to 100
No. 4 (4.75 mm) 70 to 83
No. 8 (2.36 mm) 37 to 50
No. 16 (1.18 mm) 0 to 12
pan
2.03 PERMEABLE SETTING BED AGGREGATE
A. Provide Permeable Setting Bed Aggregate materials conforming to ASTM C 33 and
gradation requirements of ASTM D 448 No. 8 as presented in Table 3.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 7
TABLE 3
PERMEABLE SETTING BED AGGREGATE
GRADATION REQUIREMENTS
ASTM No. 8
Sieve Size Percent Passing
½ in (12.5 mm) 100
3/8 in (9.5 mm) 85 to 100
No. 4 (4.75 mm) 10 to 30
No. 8 (2.36 mm) 0 to 10
No. 16 (1.18 mm) 0 to 5
2.04 PERMEABLE BASE AGGREGATE
A. Provide Permeable Base Aggregate materials conforming to ASTM C 33 and gradation
requirements of ASTM D 448 No. 57 as presented in Table 4.
TABLE 4
PERMEABLE BASE AGGREGATE
GRADATION REQUIREMENTS
ASTM No. 57
Sieve Size Percent Passing
1-1/2 in (37.5 mm) 100
1 in (25 mm) 95 to 100
1/2 in (12.5 mm) 25 to 60
No. 4 (4.75 mm) 0 to 10
No. 8 (2.36 mm) 0 to 5
2.05 PERMEABLE SUBBASE AGGREGATE
A. Provide Permeable Subbase Aggregate materials conforming to ASTM C 33 and
gradation requirements of ASTM D 448 No. 2 as presented in Table 5.
TABLE 5
PERMEABLE SUBBASE AGGREGATE
GRADATION REQUIREMENTS
ASTM No. 2
Sieve Size Percent Passing
3 in (75 mm) 100
2-1/2 in (63 mm) 90 to 100
2 in (50 mm) 35 to 70
1-1/2 in (37.5 mm) 0 to 15
3/4 (19 mm) 0 to 5
Note: For all aggregates, provide washed, clean, have zero plasticity, free from deleterious or
foreign matter, crushed, angular rock and contain no No. 200 sieve size aggregate
materials used in the construction of permeable pavement. Aggregate materials serve as
the structural load bearing platform of the pavement as well as a temporary receptor for
the infiltrated water that is collected through the openings in the pavement’s surface.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 8
2.06 GEOTEXTILE (Optional depending on soil conditions)
A. Provide Geotextile material conforming to the following performance characteristics,
measured per the test methods referenced:
1. 4 oz., nonwoven needle punched geotextile composed of 100% polypropylene
staple fibers that are inert to biological degradation and resists naturally
encountered chemicals, alkalis, and acids.
2. Grab Tensile Strength: ASTM D 4632: 115 lbs.
3. Grab Tensile Elongation: ASTM D 4632: 50%
4. Trapezoidal Tear: ASTM D4533: 50 lbs.
5. Puncture: ASTM D4833: 65 lbs.
6. Apparent Opening Size: ASTM D 4751: 0.212 mm, 70 U.S. Sieve
7. Permittivity: ASTM D 4491: 2.0 sec -1
8. Flow Rate: ASTM D 4491: 140 gal/min/s.f.
B. As supplied by Unilock (add location, address, City, State and Zip)
Contact: (Insert Unilock representative name and phone number) or your local Territory
Manager
1. Carthage Mills – FX-40HS
2. U.S. Fabrics – US 115NW
3. Mirafi – 140N
2.07 EDGE RESTRAINTS
A. Concrete Edge Restraint as indicated.
B. Plastic and Metal Edge Restraints:
1. Permaloc, www.permaloc.com
a. Material Type: Aluminum
b. Model No.: 3 inch GeoEdge capture plate and geogrid
2. SEK Surebond
a. Model No.: 8 feet PermEdge with attached geogrid
Note: The provision of suitable edge restraints is critical to the satisfactory performance of
interlocking concrete block pavement. Abut pavers tightly against the restraints to prevent
rotation under load and any consequent spreading of joints. Install sufficiently stable edge
restraints that are, in addition to providing suitable edge support for the paver units, able
to withstand the impact of temperature changes, vehicular traffic and/or snow removal
equipment.
Curbs, gutters or curbed gutter, constructed to the dimensions of municipal standards
(noting that these standards generally refer to cast-in-place concrete sections), are
considered to be acceptable edge restraints for heavy duty installations. Where extremely
heavy industrial equipment is involved such as container handling equipment, review the
flexural strength of the edge restraint carefully particularly if a section that is flush with the
surface is used and may be subjected to high point loading.
2.08 ACCESSORIES (Optional depending on project needs)
A. [Cleaners] [Sealers]
1. Supplier: Unilock (add location, address, City, State and Zip)
Contact: (Insert Unilock representative name and phone number) or your local
Territory Manager
2. Material Type and Description: (Specify material type and description)
3. Material Standard: (Specify material standard)
Note: Generally sealing permeable pavers for utilitarian uses such as parking lots is not
necessary. Consult with your product representative prior to specifying or remove section
2.08 Accessories.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 9
PART 3 EXECUTION
3.01 EXAMINATION
A. Examine areas indicated to receive paving for compliance with requirements for
installation tolerances and other conditions affecting performance for the following items
before placing the Permeable Concrete Pavers.
1. Verify that subgrade preparation, compacted density and elevations conform to
specified requirements.
2. Verify that Geotextiles, if applicable, have been placed according to drawings and
specifications.
3. Verify that Permeable Base and Subbase Aggregate materials, thickness,
compacted density, surface tolerances and elevations conform to specified
requirements.
4. Provide written density test results for soil subgrade, Permeable Base and
Subbase Aggregate materials to the Owner, General Contractor and paver
installation subcontractor.
5. Verify location, type, and elevations of edge restraints, concrete collars around
utility structures, and drainage inlets.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
1. Beginning of bedding sand and paver installation signifies acceptance of base and
edge restraints.
3.02 PREPARATION
A. Verify that the subgrade soil is free from standing water.
B. Stockpile Permeable Setting Bed, Joint, Base and Subbase Aggregate materials such
that they are free from standing water, uniformly graded, free of any organic material or
sediment, debris, and ready for placement.
C. Remove any excess thickness of soil applied over the excavated soil subgrade to trap
sediment from adjacent construction activities before placing the Geotextile and
Permeable Subbase Aggregate materials.
D. Keep area where pavement is to be constructed free from sediment during entire job.
Remove and replace all Geotextile, Permeable Joint, Setting Bed, Base and Subbase
Aggregate materials contaminated with sediment with clean materials.
E. Complete all subdrainage of underground services within the pavement area in
conjunction with subgrade preparation and before the commencement of Permeable
Subbase Aggregate construction.
F. Prevent damage to underdrain pipes, overflow pipes, observation wells, or inlets and
other drainage appurtenances during installation. Report all damage immediately.
G. Compact soil subgrade uniformly to at least 90 percent of Standard Proctor Density per
ASTM D 698 for pedestrian areas. Compact soil subgrade uniformly to at least 95
percent Modified Proctor per ASTM D 1557 for vehicular areas.
H. Proof-roll prepared subgrade according to requirements in Division 31 Section "Earth
Moving" to identify soft pockets and areas of excess yielding. Excavate soft spots,
unsatisfactory soils, and areas of excessive pumping or rutting and replace with
compacted backfill or fill as directed.
Note: Base compaction and proof-rolling of the subgrade soil on the recommendations of the
Design Engineer. Request the Architect/Engineer to inspect subgrade preparations,
elevations and conduct density tests for conformance to specifications.
Note: Mechanical tampers (jumping jacks) are recommended for compaction of soil subgrade
and aggregate base around lamp standards, utility structures, building edges, curbs, tree
wells and other protrusions. Compact areas, not accessible to roller compaction
equipment, to the specified density with mechanical tampers. CAUTION – Proceed with
care around the perimeters of excavations, buildings, curbs, etc. These areas are
especially prone to consolidation and settlement. Do not place wedges of backfill in these
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 10
areas. If possible particularly in these areas, proceed with backfilling and compacting in
shallow lifts, parallel to the finished surface.
3.03 INSTALLATION
A. EDGE RESTRAINTS
1. Provide edge restraints as indicated.
a. Install job-built concrete edge restraints to comply with requirements in
Division 3 Section "Cast-in-Place Concrete." (Add section number and match
specification name)
b. Provide concrete edge restraint along the perimeter of all paving as specified.
Install the face of the concrete edge restraint, where it abuts pavers vertical
down to the subbase.
c. Construct concrete edge restraint to dimensions and level specified and
support on a compacted subbase not less than 6 in (150 mm) thick.
2. Provide plastic or metal edge restraints as indicated. (Delete if not being used).
a. Provide plastic or metal edge restraints along the perimeter of all paving as
indicated and supported on a minimum of 6 inches (150 mm) of Base
Aggregate.
b. Provide 10” spiral galvanized or stainless steel spike to fasten plastic edge
restraint at 24 inches on center for straight sections and 12 inches on center for
curved sections.
B. GEOTEXTILES (Delete if not being used).
1. Provide separation geotextile on bottom and sides of prepared soil subgrade.
Secure in place to prevent wrinkling or folding from equipment tires and tracks.
2. Overlap ends and edges a minimum of 18 in. (450 mm) in the direction of drainage.
C. PERMEABLE BASE AND SUBBASE AGGREGATE
1. Provide the Permeable Subbase Aggregate in uniform lifts not exceeding 6 in.,
(150 mm) loose thickness and compact to at least 95 percent as per ASTM D 4254
to depths as indicated.
2. Compact the Permeable Subbase Aggregate material with at least two passes in
the vibratory mode then at least two in the static mode with a minimum 10 ton
vibratory roller until there is no visible movement. Do not crush aggregate with the
roller.
3. Tolerance: Do not exceed the specified surface grade of the compacted Permeable
Subbase Aggregate material more than ±3/4 in. (20 mm) over a 10 ft. (3 m) long
straightedge laid in any direction.
4. Provide the Permeable Base Aggregate material in uniform lifts not exceeding 6 in.
(150 mm) over the compacted Permeable Subbase Aggregate material and
compact to at least 95 percent as per ASTM D 4254 to depths as indicated.
5. Compact the Permeable Base Aggregate material with at least two passes in the
vibratory mode then at least two in the static mode with a minimum 10 ton vibratory
roller until there is no visible movement. Do not crush aggregate with the
compaction device.
6. Tolerance: Do not exceed the specified surface grade of the compacted Permeable
Base Aggregate material more than ±1/2 in. (13 mm) over a 10 ft. (3 m) long
straightedge laid in any direction.
7. Grade and compact the upper surface of the Permeable Base Aggregate material
sufficiently to prevent infiltration of the Permeable Setting Bed Aggregate material
both during construction and throughout its service life.
Note: In-place density of the Permeable Base and Subbase Aggregate materials may be
checked per ASTM D 4254. Establish a Compacted density of 95% of the
laboratory index density for the subbase and base stone.
D. PERMEABLE SETTING BED AGGREGATE
1. Provide and spread Permeable Setting Bed aggregate evenly over the Permeable
Base Aggregate course and screed to a nominal thickness of 1-1/2 in. (40 mm).
a. Protect screeded Permeable Setting Bed Aggregate from being disturbed.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 11
b. Screed only the area which can be covered by pavers in one day.
c. Do not use Permeable Setting Bed Aggregate material to fill depressions in the
base surface.
2. Keep moisture content constant and density loose and constant until Concrete
Pavers are set and compacted.
3. Inspect the Permeable Setting Bed Aggregate course prior to commencing the
placement of the permeable concrete pavers.
4. Inspect the Setting Bed Aggregate course prior to commencing the placement of
the Permeable Concrete Pavers. Acceptance of the Setting Bed Aggregate occurs
with the initiation of Permeable Concrete Paver placement.
E. PERMEABLE CONCRETE PAVERS
1. Replace unit pavers with chips, cracks, voids, discolorations, and other defects that
might be visible in finished work.
2. Mix Concrete Pavers from a minimum of three (3) bundles simultaneously drawing
the paver vertically rather than horizontally, as they are placed, to produce uniform
blend of colors and textures. (Color variation occurs with all concrete products. This
phenomenon is influenced by a variety of factors, e.g. moisture content, curing
conditions, different aggregates and, most commonly, from different production
runs. By installing from a minimum of three (3) bundles simultaneously, variation in
color is dispersed and blended throughout the project).
3. Exercise care in handling face mix pavers to prevent surfaces from contacting
backs or edges of other units.
4. Provide Permeable Concrete Pavers using joint pattern as indicated. Adjust joint
pattern at pavement edges such that cutting of edge pavers is minimized. Cut all
pavers exposed to vehicular tires no smaller than one-third of a whole paver.
5. Use string lines or chalk lines on Permeable Setting Bed aggregate to hold all
pattern lines true.
6. Set surface elevation of pavers 1/8 in. (3 mm) above adjacent drainage inlets,
concrete collars or channels.
7. Place units hand tight against spacer bars. Adjust horizontal placement of laid
pavers to align straight.
a. When installation is performed with mechanical equipment, use only unit
pavers with spacer bars on sides of each unit.
8. Provide space between paver units of 1/32 in. (1 mm) wide to achieve straight
bond lines.
9. Prevent joint (bond) lines from shifting more than ±1/2 in. (±15 mm) over 50 ft. (15
m) from string lines.
10. Fill gaps between units or at edges of the paved area that exceed 3/8 inch (10 mm)
with pieces cut to fit from full-size unit pavers.
11. Cut unit pavers with motor-driven masonry saw equipment to provide clean, sharp,
unchipped edges. Cut units to provide pattern indicated and to fit adjoining work
neatly. Use full units without cutting where possible. Hammer cutting is not
acceptable.
12. Prevent all traffic on installed pavers until Permeable Joint Aggregate has been
vibrated into joints. Keep skid steer and forklift equipment off newly laid pavers
that have not received initial compaction and Permeable Joint Aggregate material. .
13. Vibrate pavers into leveling course with a low-amplitude plate vibrator capable of a
to 5000-lbf (22-kN) compaction force at 80 to 90 Hz. Perform at least three passes
across paving with vibrator. Vibrate under the following conditions:
a. After edge pavers are installed and there is a completed surface.
b. Compact installed concrete pavers to within 6 feet (1,800 mm) of the laying
face before ending each day's work. Cover pavers that have not been
compacted and leveling course on which pavers have not been placed, with
nonstaining plastic sheets to prevent Permeable Setting Bed Aggregate from
becoming disturbed.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 12
14. Protect face mix Concrete Paver surface from scuffing during compaction by
utilizing a urethane pad.
15. Remove any cracked or structurally damaged pavers and replace with new units
prior to installing Permeable Joint Opening Aggregate material.
16. Provide, spread and sweep Permeable Joint Opening Aggregate into joints
immediately after vibrating pavers into Permeable Setting Bed course until full.
Vibrate pavers and add Permeable Joint Aggregate material until joints are
completely filled, then remove excess material. This will require at least 4 passes
with a plate compactor.
17. Remove excess Permeable Joint Aggregate broom clean from surface when
installation is complete.
3.04 FIELD QUALITY CONTROL
A. Verify final elevations for conformance to the drawings after sweeping the surface clean.
1. Prevent final Concrete Paver finished grade elevations from deviating more than
±3/8 in. (±10 mm) under a 10 ft (3 m) straightedge or indicated slope, for finished
surface of paving.
B. Lippage: No greater than 1/32 in. (0.8 mm) difference in height between Permeable
Concrete Pavers and adjacent paved surfaces.
3.05 REPAIRING, CLEANING AND SEALING
A. Remove and replace unit pavers that are loose, chipped, broken, stained, or otherwise
damaged or that do not match adjoining units. Provide new units to match adjoining units
and install in same manner as original units, with same joint treatment and with no
evidence of replacement.
B. Cleaning: Remove excess dirt, debris, stains, grit, etc. from exposed paver surfaces;
wash and scrub clean.
1. Clean Permeable Concrete Pavers in accordance with the manufacturer’s written
recommendations.
C. Seal as indicated. (If not indicated elsewhere in the contract documents, sealing is not
required and remove this section 3.05, C.)
1. Apply Sealer for Permeable Concrete Pavers in accordance with the sealer and
paver manufacturer’s written recommendations.
3.06 PROTECTION
A. Protect completed work from damage due to subsequent construction activity on the site.
3.07 PERMEABLE JOINT AGGREGATE MATERIAL REFILLING
A. Remove all debris from joint and provide additional Permeable Joint Aggregate
material after 120 days and before 150 days after date of Substantial
Completion/Provisional Acceptance.
1. Fill Permeable Joint Aggregate material full to the lip of the paver.
NOTE: This preventative maintenance requirement is very important to include in your
specification to help increase the long term function of the system. This is a good
item to mention during the prebid meeting.
3.08 LIFE CYCLE ACTIVITIES
A. Paver cleaning: Clean Permeable Concrete Pavers as needed to remove staining, dirt,
debris, etc.
1. Clean per manufacturers recommendations.
B. Maintenance: Permeable Joint Aggregate Material.
1. Annually inspect Permeable Joint Aggregate material for areas clogged with debris.
2. Vacuum or sweep as necessary to restore surface infiltration.
3. Remove debris by vacuuming or sweeping Permeable Joint Aggregate
a. Replenish removed Permeable Joint Aggregate material with clean aggregate
material flush to paver lip.
Revised: January 1, 2015 UNILOCK PERMEABLE PAVER SPECIFICATION 32
14 13.19
32-14-13 Page 13
b. Sweep excess material from paver surface.
END OF SECTION