HomeMy WebLinkAboutEAST RIDGE THIRD FILING - FDP - FDP170016 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSUTILITY
EASEMENT
UTILITY
EASEMENT
EDGE OF ASPHALT TO
EDGE OF ASPHALT
(DRAINAGE TO
CENTERLINE BASED
ON GRADING SEE RD
P&P FOR MORE
DETAIL)
UTILITY
EASEMENT
UTILITY
EASEMENT
EDGE OF ASPHALT TO
EDGE OF ASPHALT
(DRAINAGE TO
CENTERLINE BASED
ON GRADING SEE RD
P&P FOR MORE
DETAIL)
JUNE, 2017
UTILITY PLANS FOR:
MONTAGE TOWNHOMES
East Ridge Holdings LLC.
Landon Hoover
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
DEVELOPER / APPLICANT
GEOTECHNICAL ENGINEER
CTL Thompson Inc.
351 Linden Street, Unit 140
Fort Collins, Colorado 80524
(303) 206-9455
PROJECT TEAM:
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing
department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the
review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason
as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the
construction phase.
DISCLAIMER STATEMENT:
I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort
Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions,
and record conditions that I have noted on these plans.
CERTIFICATION STATEMENT:
Russell + Mills Studios
Craig Russell, RLA, ASLA
141 S. College Avenue, Suite 104
Fort Collins, CO 80524
(970) 484-8855
PLANNER/
LANDSCAPE ARCHITECT
UTILITY CONTACT LIST: *
BEING A REPLAT OF TRACTS A, B & C OF EAST RIDGE SECOND FILING,
IN THE EAST HALF OF SECTION 8, T7N, R68W OF THE 6TH P.M.
CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
Galloway & Company
James E. Prelog
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
A. GENERAL NOTES
1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area
Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the
most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins.
2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans
after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans.
4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said
engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer
who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of
Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these
plans.
5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the
date of approval of the plans by the City of Fort Collins Engineer.
6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to
verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for
unknown underground utilities.
7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to
have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective
representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all
existing utilities that conflict with the proposed improvements shown on these plans.
8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings
required.
9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the
design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely
fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
18''SS 18''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8
''SS 8''SS 8''SS 8''SS 8''SS
12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W 12''W 12''W 12''W 12''W 12''W
18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 12''W 12''W 12''W 12''W 12''W
8''W 8''W 12''W 12''W 12''W 12''W 12''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS 8''SS
8''SS 8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W
18''SS 18''SS 18''SS 18''SS 18''SS
S S S
S S S S S S S S
S S S S S S S S S
S S
S S S S S S S S
S S S
S
S
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
18''SS 18''SS 18''SS 18''SS 18''SS
LOT 1
LOT 2
LOT 16 LOT 1
LOT 15
LOT 3 LOT 14
LOT 4 LOT 13
LOT 5 LOT 12
LOT 6 LOT 11
LOT 6 LOT 13
LOT 5
8''SS
SS 8''SS 8''SS
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W
12''W 12''W
8''SS8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
S S
S S S S S S S S S S
S
S S S S S S S S S S
S S
S S S S S S S S S
S S S S S
S
S
S
S
S
LOT 4
LOT 5
LOT 1 LOT 2
LOT 3 LOT 4
LOT 5
LOT 29 LOT 28 LOT 27
LOT 31 LOT 30 LOT 25
LOT 7 LOT 8 LOT 9
LOT 24 LOT 23
LOT 6
LOT 26
LOT 10 LOT 11 LOT 12 LOT 13 LOT 14
LOT 19
LOT 22 LOT 21 LOT 20
LOT 18
LOT 17
LOT 4 LOT 1 LOT 2
LOT 3 LOT 4 LOT 5 LOT 6 LOT 7
LOT 8 LOT 9 LOT 10
LOT 11
ACT Q TRACT P
BLOCK 21
BLOCK 19
(UNPLATTED)
OWNER: WHITHAM FARMS LLC
REC. NO. 20010120159
PROJECT BOUNDARY
EXISTING
20' DRAINAGE
EASEMENT TO BE
VACATED
TEMPORARY TURN AROUND EASEMENT
TO BE VACATED WITH THIS PLAT
PROPOSED 36" STORM DRAIN PER
EAST RIDGE SECOND FILING UTILITY PLANS
NORTHEAST CORNER
SECTION 8, T.7N., R.68W.
FOUND 2 1/2" ALUMINUM CAP
ON #6 REBAR, LS 28285, 2000
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_PH01_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
8''SS 8''SS
8''SS
8''SS 8''SS 8''SS
18''SS
18''SS
8''SS 8''SS
8''SS
8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8
''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
18''SS 18''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
12''W 12''W 12''W 12''W 12''W 12''W
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
8''SS
8'
'SS 8''SS
18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS
8''W 8''W
8''W 8''W 8''W 8''W 8''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W 12''W 12
''W 12''W 12''W 12''W
8''W
8''W 8''W 12''W 12''W
8''SS 8''SS
8''SS8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8''SS 8''SS
8''SS 8''SS 8''SS
8''W
8''W 8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS
8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS
8''SS 8''SS 8''SS 8''SS
8''SS 8''SS 8''SS 8''SS
8''W
8''W 8''W 8''W 8''W
8''W 8''W
8''W 8''W
8''W
8''W
8''W
8''W
8''W
8'
'W
8''W 8''W
8''W 8''W
18''SS 18''SS
8''W
8''W
S
S
S
S
12''W 12''W
LOT 1
LOT 2
LOT 16 LOT 1
LOT 15
LOT 3 LOT 14 LOT 3
LOT 16
LOT 2 LOT 17
LOT 18
LOT 2 LOT 3 LOT 4
LOT 5 LOT 6
LOT 13 LOT 12 LOT 11 LOT 10
LOT 1
LOT 14
LOT 7
LOT 9 LOT 8
BLOCK 7
BLOCK 8
BLOCK 9
BLOC
HELLDIVER DRIVE
(PRIVATE DRIVE)
PRIVATE DRIVE B
BARNSTORMER STREET
3.8%
2.3%
2.2%
2.3%
2.5%
2.0%
2.6%
TRACT C
NAVION LANE
YEAGER STREET
BARNSTORMER STREET
TRACT M
TRACT A
EAST RIDGE
SECOND FILING
50' RAILROAD RIGHT OF WAY
BOOK 245, PAGE 76
& REC. NO. 99035876
2.1%
1.7%
2.2%
LOT 1
BLOCK 1
LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT 7 LOT 8 LOT 9 LOT 10 LOT 11
LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18
LOT 19 LOT 20 LOT 21 LOT
22
LOT 23 LOT 24
LOT 61 LOT 62 LOT 63 LOT 64 LOT 65 LOT 66
LOT 67 LOT 68 LOT 69 LOT 70 LOT 71 LOT 72
LOT 73 LOT 74 LOT 76 LOT 77 LOT 78
LOT 79 LOT 80 LOT 81 LOT
82
LOT 83 LOT 84
LOT
BLOCK 1
LOT 6 LOT 7
LOT 9 LOT 8
LOT 2 LOT 3 LOT 4
LOT 7 LOT 6 LOT 5
LOT 1 LOT 2
LOT 3 LOT 4
LOT 5
LOT 29 LOT 28 LOT 27
LOT 31 LOT 30 LOT 25
LOT 7 LOT 8 LOT 9
LOT 24 LOT 23
LOT 6
LOT 26
LOT 1
LOT 8
BLOCK 9
BLOCK 20
BLOCK 21
HELLDIVER DRIVE
(PRIVATE DRIVE)
PRIVATE DRIVE C
BARNSTORMER STREET
BARNSTORMER STREET
TRACT B
2.6%
2.6%
2.2%
2.1%
1.9%
MARQUISE STREET
2.1%
1.0%
0.9%
2.1%
1.8%
2.0%
2.0%
LOT
22
LOT 23 LOT 24
LOT 25 LOT 26 LOT 27 LOT 28 LOT 29 LOT 30
LOT 31 LOT 32 LOT 33 LOT 34 LOT 35 LOT 36
LOT 37 LOT 38 LOT 39 LOT 40 LOT 41 LOT 42
LOT 43 LOT 44 LOT 46 LOT 47 LOT 48
LOT 50 LOT 51 LOT 52 LOT
53
LOT
82
LOT 83 LOT 84
LOT 85 LOT 86 LOT 87 LOT 88 LOT 89 LOT 90
LOT 91 LOT 92 LOT 93 LOT 94 LOT 95 LOT 96
LOT 97 LOT 98 LOT 99 LOT 100 LOT 101 LOT 102
LOT 103 LOT 104 LOT 105 LOT 106 LOT 107 LOT 108
LOT 109 LOT 110 LOT 112
BLOCK 1
BLOCK 1
BLOCK 1
BLOCK 1
HELLDIVER DRIVE
(PRIVATE DRIVE)
LOT 8 LOT 9
LOT 24 LOT 23
LOT 10 LOT 11 LOT 12 LOT 13 LOT 14
LOT 19
LOT 22 LOT 21 LOT 20
(UNPLATTED)
OWNER: WHITHAM FARMS LLC
REC. NO. 20010120159
HELLDIVER DRIVE
(PRIVATE DRIVE)
PRIVATE DRIVE D
BARNSTORMER STREET
1.9%
2.3%
1.0%
TRACT B
50' RAILROAD RIGHT OF WAY
BOOK 245, PAGE 76
& REC. NO. 99035876
2.0%
2.0%
LOT 50 LOT 51 LOT 52 LOT
53
LOT 54
LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60
LOT 109 LOT 110 LOT 112 LOT 113 LOT 114
LOT 115 LOT 116 LOT 117 LOT 118 LOT 119 LOT 120
BLOCK 1
BLOCK 1
TRACT E
LOT 112
LOT 49
7.7%
6.2%
3.9%
3.6%
3.0%
14.7%
5.8%
2.7%
4.1%
6.7%
3.7%
3.6%
-3:1
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_GR01-02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
30Feet 0 30
30
60 90
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_GR03_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
30Feet 0 30
30
60 90
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_GR03_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
30Feet 0 30
30
60 90
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_GR03_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
20Feet 0 20
20
40 60
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_GR03_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
S S S S S S
S S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
8''SS
8''W 8''W
8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''W
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
8''SS
SS 8''SS 8''SS
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
PROPOSED RIGHT-OF-WAY
EXISTING WATER MAIN
PROPOSED 8" WATER MAIN
PROPOSED STORM SEWER
EXISTING STORM SEWER
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
KEYMAP
( IN FEET )
1 inch = ft.
20Feet 0 20
20
40 60
PROPOSED RIGHT-OF-WAY
EXISTING WATER MAIN
PROPOSED 8" WATER MAIN
PROPOSED STORM SEWER
EXISTING STORM SEWER
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
S S S S S
S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
HELLDIVER DRIVE
BARNSTORMER STREET
20' EOA-EOA
32' UTILITY, DRAINAGE, ACCESS,
EMERGENCY ACCESS EASEMENT
10+00 11+00 12+00 13+05.08
TRACT A
BLOCK 1
TRACT B
BLOCK 1
TRACT C
LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12
LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18
LOT 62 LOT 63 LOT 64 LOT 65 LOT 66
LOT 67 LOT 68 LOT 69 LOT 70 LOT 71 LOT 72
LOT 73 LOT 74 LOT 75 LOT 76 LOT 77 LOT 78
STA. 10+33.5
STA. 10+36.5
STA. 10+53.5
STA. 10+56.5
STA. 10+73.5
STA. 10+76.5
STA. 10+93.5
STA. 10+96.5
STA. 11+13.5
STA. 11+16.5
STA. 11+33.5
STA. 11+36.5
STA. 11+88.5
STA. 11+91.5
STA. 12+08.5
8''SS
8''W 8''W
8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''W
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
HELLDIVER DRIVE
BARNSTORMER STREET
PRIVATE DRIVE D
SEE SHEET RD04
8''SS
8''W 8''W
8''SS 8''SS
8''SS 8''SS
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''W 8''W
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
40+00
45+42.97 45+00 44+00 43+00 42+00 41+00
TRACT B
TRACT A
BLOCK 1
BLOCK 1
TRACT D
LOT 19 LOT 20 LOT 21 LOT 22 LOT 23 LOT 24
LOT 25 LOT 26 LOT 27 LOT 28 LOT 29 LOT 30
LOT 31 LOT 32 LOT 33 LOT 34 LOT 35 LOT 36
LOT 37 LOT 38 LOT 39
4925
4930
4935
4940
4945
4950
4955
4925
4930
4935
4940
4945
4950
4955
59+50 60+00 61+00 62+00
STA=51+38.59 (SANITARY 3)
STA=60+00.00 SANITARY 3.1
SSMH 3.1
4'Ø MH
RIM=4944.83
INV IN (8" W)=4935.45
INV IN (8" E)=4935.45
INV OUT (8" N)=4935.25
DEPTH=9.58
131.60 LF - 8'' PVC @ 0.40%
STA=61+31.60
SSMH 3.1-1
4'Ø MH
RIM=4945.55
INV OUT (8" W)=4935.98
DEPTH=9.57
PROPOSED
GRADE
EXISTING
GROUND
4920
4925
4930
4935
4940
4945
4950
4955
4920
4925
4930
4935
4940
4945
4950
4955
53+50 53+00 52+00 51+00 50+00 49+50
STA=60+00.00 (SANITARY 3.1)
STA=51+38.59 SANITARY 3
SSMH 3.1
4'Ø MH
RIM=4944.83
INV IN (8" W)=4935.45
INV IN (8" E)=4935.45
INV OUT (8" N)=4935.25
4920
4925
4930
4935
4940
4945
4950
4955
4920
4925
4930
4935
4940
4945
4950
4955
81+00 80+00 79+00 78+00 77+00 76+00 75+00 74+00 73+00 72+00 71+00 70+00 69+50
STA=70+00.00
SSMH 4
4'Ø MH
RIM=4941.64
INV IN (8" N)=4930.28
INV IN (8" W)=4930.28
INV OUT (8" E)=4930.08
DEPTH=11.56
146.50 LF - 8'' PVC @ 0.40%
STA=80+00.00 (SANITARY 4.1)
STA=71+46.50 SANITARY 4
SSMH 4.1
4'Ø MH
RIM=4943.26
INV IN (8" N)=4931.06
INV IN (8" E)=4931.06
INV OUT (8" S)=4930.86
DEPTH=12.40
385.87 LF - 8'' PVC @ 0.40%
STA=75+32.37
SSMH 4.2
4'Ø MH
RIM=4945.57
INV IN (8" N)=4932.81
INV OUT (8" S)=4932.61
DEPTH=12.96
81.75 LF - 8'' PVC @ 0.40%
STA=90+00.00 (SANITARY 4.3)
STA=76+14.11 SANITARY 4
SSMH 4.3
4'Ø MH
RIM=4946.23
INV IN (8" N)=4933.33
INV IN (8" E)=4933.33
INV OUT (8" S)=4933.13
DEPTH=13.10
412.07 LF - 8'' PVC @ 0.40%
STA=80+26.19
SSMH 4.4
4'Ø MH
RIM=4946.24
INV OUT (8" S)=4934.98
DEPTH=11.26
4920
4925
4930
4935
4940
4945
4950
4920
4925
4930
4935
4940
4945
4950
79+50 80+00 81+00 82+00
143.69 LF - 8'' PVC @ 0.40%
STA=81+43.69
SSMH 4.1-1
4'Ø MH
RIM=4943.77
INV OUT (8" W)=4931.64
DEPTH=12.14
STA=71+46.50 (SANITARY 4)
STA=80+00.00 SANITARY 4.1
SSMH 4.1
4'Ø MH
RIM=4943.26
INV IN (8" N)=4931.06
INV IN (8" E)=4931.06
INV OUT (8" S)=4930.86
DEPTH=12.40
PROPOSED
GRADE
EXISTING
GROUND
4920
4925
4930
4935
4940
4945
4950
4955
4920
4925
4930
4935
4940
4945
4950
4955
89+50 90+00 91+00 92+00
142.13 LF - 8'' PVC @ 0.40%
STA=91+42.13
SSMH 4.3-1
4'Ø MH
RIM=4947.12
INV OUT (8" W)=4933.90
DEPTH=13.22
STA=76+14.11 (SANITARY 4)
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
16+50 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+00
STA=16+01.53
INLET A6
2' ROUND AREA INLET
TBC=4950.04
INV OUT (18" E)=4944.80
DEPTH=5.23
162.56 LF - 18'' RCP @ 0.50%
STA=90+00.00 (STORM A5)
STA=14+38.97 STORM A
INLET A5
2' ROUND AREA INLET
RIM=4952.26
INV IN (18" W)=4943.99
INV IN (18" E)=4943.99
INV OUT (18" S)=4943.80
DEPTH=8.46
79.83 LF - 18'' RCP @ 0.50%
STA=13+26.49
INLET A3
CDOT TYPE C INLET
TBC=4949.21
INV IN (18" N)=4943.24
INV OUT (24" S)=4942.74
DEPTH=6.47
102.38 LF - 24'' RCP @ 0.50%
STA=12+24.11
SDMH A2
6'Ø MH
RIM=4950.03
INV IN (24" N)=4942.23
INV OUT (24" E)=4942.03
DEPTH=8.00
181.58 LF - 24'' RCP @ 0.50%
42.53 LF - 42'' RCP @ 0.52%
STA=10+00.00
EXMH A
8'Ø MH
TBC=4948.88
INV IN (42" N)=4939.40
DEPTH=9.48
STA=20+00.00 (STORM A1)
STA=10+42.53 STORM A
SDMH A1
'W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS
HELLDIVER DRIVE
PRIVATE DRIVE B
SEE SHEET RD03
LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 22 LOT 23 LOT 24
LOT 25 LOT 26
LOT 73 LOT 74 LOT 75 LOT 76 LOT 77 LOT 78 LOT 79 LOT 80 LOT 81 LOT 82 LOT 83 LOT 84
LOT 85 LOT 86
20+00 21+00
22+00 23+00
24+00 25+00 25+84.47
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS
8''W
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
19+50 20+00 21+00 22+00 23+00 24+00 25+00 26+00 26+50
STA=10+42.53
SDMH A1
7'Ø MH
RIM=4950.35
INV IN (24" W)=4941.12
INV IN (24" E)=4941.12
INV OUT (42" S)=4939.62
DEPTH=10.73
162.52 LF - 24'' RCP @ 0.50%
STA=21+62.52
SDMH A1.1
6'Ø MH
RIM=4950.80
INV IN (18" N)=4942.43
INV OUT (24" W)=4941.93
DEPTH=8.87
102.38 LF - 18'' RCP @ 0.50%
STA=22+64.90
INLET A1.2
CDOT TYPE C INLET
RIM=4950.00
INV IN (18" N)=4943.14
INV OUT (18" S)=4942.94
DEPTH=7.06
114.55 LF - 18'' RCP @ 0.50%
STA=23+79.45
8''SS
8''W 8''W
8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''W
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS
HELLDIVER DRIVE
BARNSTORMER STREET
PRIVATE DRIVE D
SEE SHEET RD04
TRACT A
TRACT B
BLOCK 1
BLOCK 1
TRACT E
5 LOT 36
LOT 37 LOT 38 LOT 39 LOT 40 LOT 41 LOT 42
LOT 43 LOT 44 LOT 45 LOT 46 LOT 47 LOT 48
LOT 49
LOT 50 LOT 51 LOT 52 LOT 53 LOT 54
LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60
5 LOT 96
LOT 97 LOT 98 LOT 99 LOT 100 LOT 101 LOT 102
LOT 103 LOT 104 LOT 105 LOT 106 LOT 107
LOT 108
LOT 109 LOT 110 LOT 111 LOT 112 LOT 113 LOT 114
LOT 115 LOT 116 LOT 117 LOT 118 LOT 119 LOT 120
38+83.97
29+90
30+00
31+00 32+00
33+00
34+00 35+00
36+00 37+00
38+00
12''W
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
S
0
4930
4935
4940
4945
4950
4955
4960
4965
4930
4935
4940
4945
4950
4955
4960
4965
29+50 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 39+00 39+50
STA=29+99.35
8''SS 8''SS 8''SS 8''SS 8''SS
8''W 8''W 8''W 8''W 8''W
HELLDIVER DRIVE
TRACT B
BLOCK 1
BLOCK 1
LOT 45 LOT 46 LOT 47 LOT 48
LOT 49
LOT 50 LOT 51 LOT 52 LOT 53 LOT 54
LOT 105 LOT 106 LOT 107
LOT 108
LOT 109 LOT 110 LOT 111 LOT 112 LOT 113 LOT 114
121+04.15
120+00 121+00
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
112+50 112+00 111+00 110+00 109+40
STA=32+25.71 (STORM B)
STA=110+00.00 STORM B3
INLET B3
CDOT TYPE C INLET
RIM=4949.92
INV IN (24" E)=4943.16
INV IN (18" W)=4943.66
INV OUT (24" S)=4943.16
DEPTH=6.76
198.76 LF - 18'' RCP @ 0.50%
STA=111+98.76
INLET B3.1
2' ROUND AREA INLET
TBC=4951.58
INV OUT (18" E)=4944.66
PROPOSED
GRADE
EXISTING
GROUND
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4920
4925
4930
4935
4940
4945
4950
4955
4920
4925
4930
4935
4940
4945
4950
4955
51+50 51+00 50+00 49+00 48+00 47+00 46+00 45+00 44+00 43+00 42+00 41+00 40+00 39+50
23.71 LF -
18'' RCP
@ 0.40%
STA=48+97.82
INLET C11
2' ROUND AREA INLET
TBC=4945.62
INV IN (18" N)=4937.12
INV OUT (18" S)=4937.12
DEPTH=8.50
24.98 LF -
18'' RCP
@ 0.40%
87.71 LF - 18'' RCP @ 0.40%
STA=50+10.52
INLET C13
2' ROUND AREA INLET
RIM=4945.82
INV IN (18" N)=4937.57
INV OUT (18" S)=4937.57
DEPTH=8.25
35.94 LF -
18'' RCP
@ 0.40%
STA=50+46.45
INLET C14
2' ROUND AREA INLET
RIM=4947.40
INV IN (18" N)=4937.72
INV OUT (18" S)=4937.72
DEPTH=9.68
24.97 LF -
18'' RCP
@ 0.40%
STA=50+71.42
INLET C15
2' ROUND AREA INLET
RIM=4946.71
INV IN (18" N)=4937.82
INV OUT (18" S)=4937.82
DEPTH=8.90
24.97 LF -
18'' RCP
8''SS 8''SS 8''SS 8''SS
8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS
8''W 8''W 8''W
VIGILANTE LANE
SKYRAIDER WAY
VICOT WAY
TRACT G
TRACT F
TRACT F
LOT 24
LOT 25
LOT 26
LOT 27
LOT 28
LOT 29
LOT 35
LOT 36
BLOCK 2
60+00 60+63.89
8''SS 8''SS 8''SS 8''SS
8''W 8''W 8''W 8''W
8''W
4920
4925
4930
4935
4940
4945
4950
4955
4920
4925
4930
4935
4940
4945
4950
4955
59+50 60+00 61+00
STA=44+11.45
SDMH C5
6'Ø FLAT TOP MH
TBC=4945.11
INV IN (24" N)=4934.48
INV IN (18" E)=4934.98
INV OUT (24" W)=4934.48
DEPTH=10.63
63.89 LF - 18'' RCP @
0.40%
STA=60+63.89
INLET C5.1
CDOT TYPE C INLET
TBC=4942.70
INV OUT (18" W)=4935.23
DEPTH=7.47
PROPOSED
GRADE
EXISTING
GROUND
57+00
4920
4925
4930
4935
4940
4945
4950
4955
4960
4920
4925
4930
4935
4940
4945
4950
4955
4960
57+00 56+00 55+00 54+00 53+00 52+00 51+00 50+00 49+50
122.97 LF - 24'' RCP @ 0.40%
STA=52+82.07
INLET D4
2' ROUND AREA INLET
TBC=4946.08
INV IN (24" W)=4935.66
INV OUT (24" E)=4935.66
DEPTH=10.43
28.53 LF -
24'' RCP
@ 0.40%
STA=50+05.25
EXMH D
120 X 120 INCH RECTANGULAR STRUCTURE
TBC=4944.37
INV IN (30" W)=4933.67
DEPTH=10.70
43.94 LF - 30'' RCP
@ 0.40%
40.86 LF - 30''
RCP @ 0.40%
STA=50+95.69
SDMH D2
6'Ø FLAT TOP MH
TBC=4946.41
INV IN (30" W)=4934.71
INV OUT (30" E)=4934.21
DEPTH=12.20
63.41 LF - 30'' RCP @ 0.40%
STA=51+59.10
SDMH D3
4'Ø FLAT TOP MH
TBC=4946.48
INV IN (24" W)=4935.16
INV IN (18" N)=4935.96
INV OUT (30" E)=4934.96
DEPTH=11.52
STA=53+10.60
SDMH D5
4'Ø FLAT TOP MH
92+00
4925
4930
4935
4940
4945
4950
4955
4925
4930
4935
4940
4945
4950
4955
92+00 91+00 90+00 89+50
STA=54+70.80
SDMH D8
4'Ø FLAT TOP MH
RIM=4946.74
INV IN (18" N)=4937.10
INV IN (18" S)=4936.61
INV OUT (18" E)=4937.11
DEPTH=10.13
24.97 LF
- 18''
RCP @
0.40%
STA=90+82.47
INLET D8.3
2' ROUND AREA INLET
RIM=4947.14
INV IN (18" S)=4937.14
INV OUT (18" N)=4937.14
DEPTH=10.00
34.77 LF -
18'' RCP @
0.40%
STA=91+17.24
INLET D8.4
2' ROUND AREA INLET
RIM=4946.34
INV IN (18" S)=4937.28
INV OUT (18" N)=4937.28
DEPTH=9.07
34.16 LF -
18'' RCP @
0.40%
STA=91+51.39
INLET D8.5
2' ROUND AREA INLET
RIM=4946.44
INV OUT (18" N)=4937.41
DEPTH=9.02
32.53 LF -
18'' RCP @
0.40%
STA=90+32.53
INLET D8.1
2' ROUND AREA INLET
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
149+50 150+00 151+00
13.02 LF - 18'' RCP @ 0.40%
STA=150+13.02
INLET E
CDOT TYPE C INLET
TBC=4941.71
INV OUT (18" NW)=4935.81
DEPTH=5.90
STA=150+00.00
CONNECTION TO EXISTING PIPE
REMOVE EXISTING FES
AND CONTINUE PIPE
INV IN (18" SE)=4935.76
PROPOSED
GRADE
EXISTING
GROUND
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
141+00 140+00 139+50
STA=140+22.75
INLET H
2' ROUND AREA INLET
TBC=4946.99
INV OUT (12" E)=4940.43
DEPTH=6.55
22.75
LF -
12''
RCP
10+00 11+00
12+00 13+00 14+00 15+00 16+00
17+00
18+00 19+00
HELLDIVER DRIVE (PRIVATE DRIVE)
HELLDIVER DRIVE STA 17+09.07
PRIVATE DRIVE B STA 21+45.35
PRIVATE DRIVE B
SEE SHEET RD03
20' EOA-EOA
TRACT B 20' UTILITY, DRAINAGE, ACCESS,
EMERGENCY ACCESS
N00°17'26"E
101.24'
L=54.98', R=34.99'
D=090°01'42"
NAVION LANE
VICOT WAY
YEAGER STREET
BARNSTORMER STREET
6' UTILITY
EASEMENT
6' UTILITY
EASEMENT
LOT 1
TRACT A
LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 BLOCK 1
LOT 7 LOT 8 LOT 9 LOT 10 LOT 11
LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 22 LOT 23 LOT 24
LOT 25 LOT 26
LOT 61 LOT 62 LOT 63 LOT 64 LOT 65 LOT 66
LOT 67 LOT 68 LOT 69 LOT 70 LOT 71 LOT 72
LOT 73 LOT 74 LOT 76 LOT 77 LOT 78 LOT 79 LOT 80 LOT 81 LOT 82 LOT 83 LOT 84
LOT 85 LOT 86
TRACT B
BLOCK 1
TRACT C
TRACT M
TYPE III DRIVE ENTRANCE
SEE SHEET DT08
S89°40'53"E
496.09'
L=34.14', R=120.00'
D=016°18'04"
L=34.14', R=120.00'
D=016°18'04"
S89°40'53"E
497.61'
4935
4940
4945
4950
4955
4960
4935
4940
4945
4950
4955
4960
19+00 20+00 21+00 22+00
23+00 24+00 25+00 26+00 27+00 28+00 29+00 29+50.76
HELLDIVER DRIVE (PRIVATE DRIVE)
HELLDIVER DRIVE STA 22+77.78
PRIVATE DRIVE C STA 31+34.13
HELLDIVER DRIVE STA 29+50.76
PRIVATE DRIVE D STA 41+33.50
PRIVATE DRIVE C
SEE SHEET RD03
PRIVATE DRIVE D
SEE SHEET RD04
20' EOA-EOA
S89°40'53"E
661.76'
MARQUISE STREET
BARNSTORMER STREET
TRACT B 20' UTILITY, DRAINAGE, ACCESS,
EMERGENCY ACCESS
6' UTILITY
EASEMENT
6' UTILITY
EASEMENT
LOT 24
LOT 25 LOT 26 LOT 27 LOT 28 LOT 29 LOT 30
LOT 31 LOT 32 LOT 33 LOT 34 LOT 35 LOT 36
LOT 37 LOT 38 LOT 39 LOT 40 LOT 41 LOT 42
LOT 43 LOT 44 LOT 46 LOT 47 LOT 48
LOT 50 LOT 51 LOT 52 LOT 53 LOT 54
LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60
LOT 84
LOT 85 LOT 86 LOT 87 LOT 88 LOT 89 LOT 90
LOT 91 LOT 92 LOT 93 LOT 94 LOT 95 LOT 96
LOT 97 LOT 98 LOT 99 LOT 100 LOT 101 LOT 102
LOT 103 LOT 104 LOT 105 LOT 106 LOT 107 LOT 108
LOT 109 LOT 110 LOT 112 LOT 113 LOT 114
LOT 115 LOT 116 LOT 117 LOT 118 LOT 119 LOT 120
TRACT A
TRACT B
TRACT A
TRACT B
BLOCK 1
BLOCK 1
BLOCK 1
BLOCK 1
TRACT D
TRACT E
S89°40'53"E
497.61'
L=35.40', R=100.00'
D=020°16'58"
L=35.40', R=100.00'
D=020°16'58"
4940
4945
4950
4955
4960
4965
4940
4945
4935
4940
4945
4950
4955
4960
4935
4940
4945
4950
4955
4960
22+00 21+00 20+00 19+50
2.00%
-2.41%
-8.33%
8.33%
0.80%
-0.80%
STA: 20+00.00
ELEV=4950.69
STA: 20+26.43
ELEV=4950.88
STA: 20+15.00
ELEV=4950.21
STA: 20+22.00
ELEV=4950.79
STA: 21+45.35
ELEV=4950.38
HP STA:20+54.47
HP ELEV:4951.01
PVI STA:20+54.47
PVI ELEV:4951.1
K:31.25
LVC:50.00
BVCS:20+29.47
BVCE:4950.91
EVCS:20+79.47
EVCE:4950.91
(4950.7)
4950.69
(4950.7)
4950.74
(4951.0)
4951.00
PROPOSED
GRADE
EXISTING
GROUND
4940
4945
4950
4955
4960
4965
4940
4945
4950
4955
4960
4940
4945
4950
4955
4960
4965
4940
4945
4950
4955
4960
4965
42+50 42+00 41+00 40+00 39+50
1.61%
-1.61%
0.80%
2.00%
8.33%
-2.25%
-8.53%
STA: 40+00.00
ELEV=4955.07
STA: 42+26.48
ELEV=4955.67
STA: 40+26.43
ELEV=4955.28
STA: 40+22.00
ELEV=4955.19
STA: 40+15.00
ELEV=4954.60
HP STA:40+43.57
HP ELEV:4955.35
PVI STA:40+52.00
PVI ELEV:4955.5
K:20.71
LVC:50.00
BVCS:40+27.00
BVCE:4955.28
EVCS:40+77.00
EVCE:4955.08
LP STA:41+33.50
LP ELEV:4954.37
PVI STA:41+33.50
PVI ELEV:4954.2
K:15.49
LVC:50.00
BVCS:41+08.50
BVCE:4954.57
EVCS:41+58.50
EVCE:4954.57
(4955.1)
4955.07
(4954.7)
4954.71
(4955.2)
4955.24
(4955.3)
4955.34
(4954.5)
4954.45
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
49+50 50+00 51+00 52+00 53+00 54+00 55+00 56+00 57+00 58+00 59+00 60+00 61+00
(4946.8)
4946.21
(4946.8)
4945.41
(4946.8)
4945.26
(4946.9)
4946.06
(4947.4)
4946.30
(4946.6)
4945.50
(4945.8)
4945.52
(4945.0)
4944.75
(4944.1)
4943.95
(4943.2)
4943.28
(4946.8)
4945.81
(4946.8)
4945.06
(4946.8)
4945.66
(4947.0)
4946.43
(4947.1)
4945.90
(4946.2)
4945.36
(4945.4)
4945.15
(4944.6)
4944.35
(4943.7)
4943.55
(4942.6)
4943.53
PROPOSED
GRADE
EXISTING
GROUND
-0.80%
-0.50%
0.50%
4935
4940
4945
4950
4955
4960
4935
4940
4945
4950
4955
4960
69+50 70+00 71+00 72+00 73+00
-8.33%
-2.00%
0.68%
-0.80%
8.24%
2.18%
STA: 70+00.00
ELEV=4946.08
STA: 71+92.04
ELEV=4946.34
STA: 71+86.00
ELEV=4946.84
STA: 71+81.50
ELEV=4946.93
STA: 72+10.11
ELEV=4946.86
HP STA:71+53.49
HP ELEV:4947.05
PVI STA:71+55.50
PVI ELEV:4947.1
K:33.76
LVC:50.00
BVCS:71+30.50
BVCE:4946.97
EVCS:71+80.50
EVCE:4946.94
(4947.3)
4946.08
(4948.1)
4946.76
(4946.6)
4946.63
(4947.9)
4946.42
(4947.6)
4947.05
PROPOSED
GRADE
EXISTING
GROUND
4930
4935
4940
4945
4950
4955
4930
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
79+50 80+00 81+00 82+00 82+50
2.25%
8.34%
-8.33%
-2.00%
-0.80%
-0.52%
0.53%
STA: 80+00.00
ELEV=4943.26
STA: 81+98.25
ELEV=4943.58
STA: 81+80.28
ELEV=4943.05
STA: 81+75.75
ELEV=4943.43
STA: 81+69.77
ELEV=4943.55
STA: 80+25.00
ELEV=4943.13
HP STA:81+38.73
HP ELEV:4943.68
PVI STA:81+43.77
PVI ELEV:4943.8
K:37.55
LVC:50.00
BVCS:81+18.77
BVCE:4943.62
EVCS:81+68.77
EVCE:4943.56
(4943.2)
(4943.5)
4943.52
(4943.4)
4943.26
(4943.7)
4943.66
PROPOSED
GRADE
EXISTING
GROUND
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
102+00 101+00 100+00 99+50
2.25%
8.33%
-8.33%
-2.00%
-0.80%
-0.50%
0.50%
0.90%
STA: 100+00.00
ELEV=4942.25
STA: 101+28.45
ELEV=4941.84
STA: 101+10.45
ELEV=4941.31
STA: 101+04.95
ELEV=4941.77
STA: 100+64.95
ELEV=4941.73
STA: 100+74.95
ELEV=4941.68
STA: 100+84.95
ELEV=4941.73
STA: 100+99.95
ELEV=4941.87
(4944.8)
4942.25
(4942.0)
4941.87
(4943.4)
4941.85
PROPOSED
GRADE
EXISTING
GROUND
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
89+50 90+00 91+00 92+00 93+00 94+00 95+00 96+00
OT 1 LOT 16 LOT 1
LOT 18
HELLDIVER DRIVE (PRIVATE DRIVE)
PRIVATE DRIVE B
BARNSTORMER STREET
VINE DRIVE
BURLINGTON NORTHERN RAILROAD
PROPOSED UTILITY PLANS FOR:
EAST RIDGE SECOND FILING
DATED : 6.30.16
LOT 1
LOT 2
LOT 3
LOT 4
LOT 5
LOT 6
LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12
LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18
LOT 19
LOT 20 LOT 21 LOT 22 LOT 23 LOT 24
LOT 25 LOT 26 LOT 27 LOT 28 LOT 29 LOT 30
LOT 31 LOT 32 LOT 33 LOT 34 LOT 35
LOT 36
LOT 61
LOT 62
LOT 63
LOT 64
LOT 65
LOT 66
LOT 67
LOT 68
LOT 69
LOT 70
LOT 71
LOT 72
LOT 73
LOT 74
LOT 75
LOT 76
LOT 77
LOT 78
LOT 82
LOT 83
LOT 84 LOT 85
LOT 86
LOT 87
LOT 88
LOT 89
LOT 90
LOT 91
LOT 92
LOT 93
LOT 94
LOT 95
LOT 96
TRACT A
BLOCK 1
TRACT B TRACT B
TRACT A
BLOCK 1
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD09.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED
BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED
AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS
OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT
IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE
HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING
UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE
METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO
CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
HELLDIVER DRIVE
PRIVATE DRIVE B
BARNSTORMER STREET
ION LANE
ER STREET
R STREET
VINE DRIVE
SF SF SF
SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF S
F SF
IP
SF
WD WD WD
IP IP IP IP IP
IP
IP IP
IP
HELLDIVER DRIVE
PRIVATE DRIVE D
PRIVATE DRIVE C
BARNSTORMER STREET
VINE DRIVE
BURLINGTON NORTHERN RAILROAD
PRIVATE DRIVE D
PRIVATE DRIVE C
SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF
SF SF SF SF SF SF SF SF SF SF
SF
WD
IP
IP IP IP
IP
IP
IP
IP
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_EC01.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_EC01.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
EC01
KEYMAP
EC02
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED
BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED
AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS
OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT
IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE
HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING
UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE
METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO
CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
HELLDIVER DRIVE
HELLDIVER DRIVE
PRIVATE DRIVE B
PRIVATE DRIVE D
PRIVATE DRIVE C
BARNSTORMER STREET
BARNSTORMER STREET
NAVION LANE
VINE DRIVE
YEAGER STREET
MARQUISE STREET
VINE DRIVE
BURLINGTON NORTHERN RAILROAD
BURLINGTON NORTHERN RAILROAD
K1
K2
L1
K3 L4
K4
K5
L5
OS1
OS2
OS3
OS4
OS5
10+00 11+00
12+00 13+00 14+00 15+00 16+00
17+00
18+00 19+00 20+00 21+00 22+00
23+00 24+00 25+00 26+00 27+00 28+00 29+00 29+50.76
20+00 21+00 21+45.35
30+00 31+00 31+34.13
STA 15+85.39, 14.75' R
STA 16+52.32, 0.00'
STA 13+08.30, 0.00' STA 25+25.77, 0.00' STA 26+10.73, 0.00'
STA 19+57.64, 0.00'
STA 22+54.52, 0.00'
1
1
2
2
5
7
6
7
8
8 8
8
8
2 2
8
1
1
HELLDIVER DRIVE
PRIVATE DRIVE B
PRIVATE DRIVE D
PRIVATE DRIVE C
BARNSTORMER STREET
NAVION LANE
THUNDERSTREAK LANE
SKYRAIDER WAY
COMET STREET
VIGILANTE LANE
SKYRAIDER WAY
VICOT WAY
SYKES DRIVE
TIMBERLINE ROAD
CRUSADER STREET
VICOT WAY
54+00 53+00 52+00 51+00 50+00
55+00
59+99.82 59+00 58+00 57+00 56+00
60+00 61+0
0 62+00 63+00
64+00 64+36.43
70+00 71+00
72+72+00 10.11
80+00 81+00 81+98.25
101+00 101
+28.45
STA 58+95.82, 0.00'
STA 55+35.84, 0.00'
STA 51+59.72, 0.00'
STA 61+91.29, 0.00'
STA 80+25.00, 0.00'
STA 61+12.93, 0.00'
STA 63+55.34, 0.30' L
STA 54+31.07, 0.00'
STA 71+86.01, 0.00'
STA 71+81.50, 0.00'
STA 64+12.43, 0.00'
STA 64+07.93, 0.00'
G6
I6
I5
I2
I4
G7
I3 I7
Fut-TL3
7
1
2
2
2
1
2
11
11
11
11
THUNDERSTREAK
LANE
VIGILANTE
LANE
FF
TIMBERLINE ROAD
CRUSADER STREET
VICOT WAY
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT01-03.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
ELCO WATER DISTRICT
DETAIL: DRAWN: DATE:
ELCO WATER DISTRICT
DETAIL: DRAWN: DATE:
TRENCH WIDTH TABLE
PVC PIPE DUCTILE IRON PIPE AC PIPE
PIPE
DIAMETER
(inches)
MAXIMUM
TRENCH WIDTH
(inches)
PIPE
DIAMETER
(inches) (inches)
TRENCH WIDTH
MAXIMUM PIPE
DIAMETER
(inches) (inches)
TRENCH WIDTH
MAXIMUM
4 28
6 30
8 32
10 34
12 36
14 38
16 40
18 42
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT01-03.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
ELCO WATER DISTRICT
DETAIL:
DRAWN: DATE:
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT01-03.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT04-12.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
o
5 CLAY CUTOFF WALL
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT04-12.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
SILT FENCE
SF
WATTLE INSTALLATION
FLOW
3'-4'
ADJACENT ROLLS SHALL
TIGHTLY ABUT
W1 NOTES:
INSTALLATION:
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, BUTT THE SECOND WATTLE TIGHTLY
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT04-12.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CURB INLET PROTECTION EROSION CONTROL BLANKET
IP
1 2 3 EROSION CONTROL BLANKET
CONCRETE WASHOUT AREA
CWA
7
4 ROCK SOCK 5 STABILIZED STAGING AREA 6 STOCKPILE MANAGEMENT
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT04-12.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
2"R.
1 1/2"R.
2'-6"
6"
4 1/2"
30"
9"
4.5"
18"
3.63"
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT04-12.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose
from the post when hit by a vehicle.
2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground.
Cross section of post
2 1/4" Anchor
3. Signs larger than 36 inches in length or width require wind bracing and special post design.
NOTES:
4. Anchor Stub and post are square steel tube (perforated).
CRITERIA FOR SINGLE POST
5. All "No Parking" signs shall be installed at 45° from Flow Line.
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT04-12.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
SILT FENCE
SF
WATTLE INSTALLATION
FLOW
3'-4'
ADJACENT ROLLS SHALL
TIGHTLY ABUT
W1 NOTES:
INSTALLATION:
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, BUTT THE SECOND WATTLE TIGHTLY
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT04-12.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CURB INLET PROTECTION VEHICLE CONTROL TRACKING PAD
IP
VTC
1 2
Mobilization Demolition Grading
Utilities
Installation
Flat work
Installation
Vertical
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DT04-12.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
1 ROCK SOCK DETAIL 2 EROSION CONTROL BLANKET 3 EROSION CONTROL BLANKET
4 STABILIZED STAGING AREA 5 STOCKPILE MANAGMENT CONCRETE WASHOUT AREA
CWA
6
Installation Landscape Demobilization
Best Management Practices (BMPs)
Structural "Installation"
Silt Fence Barriers*
Contour Furrows (Ripping / Disking)
Sediment Trap / Filter
Vehicle Tracking Pad*
Flow Barriers (Wattles)*
Inlet Filter Bags*
Any prior inlets
that could use
protecting
Rock Bags*
Any prior inlets
that could use
protecting
Terracing
Stream Flow Diversion*
Rip Rap
Collecting Asphalt / Concrete Saw Cutting Waste
*All BMPs to be Removed once Construction is Complete.
Vegetative
Temporary Seeding Planting
Any time the
site will sit
dorment
longer than
30 Days.
Mulching/Sealant
Any time the
site will sit
dorment
longer than
30 Days.
Permanent Seeding Planting
Sod Installation
Rolled Products : Netting/Blankets/Mats
Any time the
site will sit
dorment
longer than
30 Days.
Other:
AGAINST THE FIRST, DO NOT OVERLAP THE ENDS. STAKE THE WATTLES AT EACH END AND
FOUR FOOT ON CENTER. FOR EXAMPLE:
A 25 FOOT WATTLE USES 6 STAKES
A 20 FOOT WATTLE USES 5 STAKES
A 12 FOOT WATTLE USES 4 STAKES
STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF THE WATTLE. LEAVING 2 - 3 INCHES
OF THE STAKE PROTRUDING ABOVE THE WATTLE. A HEAVY SEDIMENT LOAD WILL TEND TO
PICK THE WATTLE UP AND COULD PULL IT OFF THE STAKES IF THEY ARE DRIVEN DOWN TOO
LOW. IT MAY BE NECESSARY TO MAKE A HOLE IN THE WATTLE WITH A PICK END OF YOUR
MADDOX IN ORDER TO GET THE STAKE THROUGH THE STRAW. WHEN STRAW WATTLES ARE
USED FOR FLAT GROUND APPLICATIONS, DRIVE THE STAKES STRAIGHT DOWN; WHEN
INSTALLING WATTLES ON SLOPES, DRIVE THE STAKES PERPENDICULAR TO THE SLOPE.
DRIVE THE FIRST END STAKE OF THE SECOND WATTLE AT AN ANGLE TOWARD THE FIRST
WATTLE IN ORDER TO HELP ABUT THEM TIGHTLY TOGETHER. IF YOU HAVE DIFFICULTY
DRIVING THE STAKE INTO EXTREMELY HARD OR ROCKY SLOPES, A PILOT BAR MAY BE
NEEDED TO BEGIN THE STAKE HOLE.
1"x 1" WOOD STAKES
18"-24"
BAILING WIRE OR
NYLON ROPE
WATTLE "A" WATTLE "B"
1' 2'
TYP.
1' 1'
W2 NOTES:
INSTALLATION:
STAKES SHOULD BE DRIVEN ACROSS FROM EACH OTHER AND ON EACH
SIDE OF THE WATTLE. LEAVING 4"-6" OF STAKE PROTRUDING ABOVE THE
WATTLE. BAILING WIRE OR NYLON ROPE SHOULD BE TIED TO THE
STAKES ACROSS THE WATTLE. STAKES SHOULD THEN BE DRIVEN UNTIL
THE BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG TO THE
WATTLE.
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, TO PREVENT
SHIFTING, BUTT THE SECOND WATTLE TIGHTLY AGAINST THE FIRST. DO
NOT OVERLAP THE ENDS. STAKES SHOULD BE DRIVEN 1 FT. FROM END,
ACROSS FROM AND ON EACH SIDE OF WATTLE LEAVING 4"-6" OF STAKE
PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR NYLON ROPE
SHOULD BE TIED TO STAKES IN AN HOUR GLASS FORMATION (FRONT TO
BACK OF WATTLE "A", ACROSS TO FRONT OF WATTLE "B", ACROSS TO
BACK AND BACK TO FRONT OF WATTLE "A"). STAKES SHOULD THEN BE
DRIVEN IN UNTIL BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG
TO THE WATTLE.
SEDIMENT
DEPOSITION
ZONE
STORM WATER LINE
WEIGHTED WATTLE
OR ROCK SOCK
LIP OF GUTTER
SIDEWALK
EXISTING OR
PROPOSED INLET
TOP BACK CURB
FLOW LINE
SEDIMENT
DEPOSITION
ZONE
STORM WATER LINE
LIP OF GUTTER
WEIGHTED WATTLE
OR ROCK SOCK
AT 45 DEG. TO CURB
SIDEWALK
TOP BACK CURB
FLOW LINE
SIDEWALK
TOP BACK CURB
FLOW LINE
W4 NOTES:
1. NUMBER OF WATTLES AND SPACING SHOULD BE DETERMINED BY THE SLOPE AND SITE CONDITIONS.
2. TUBULAR MARKERS SHALL MEET THE REQUIREMENTS OF MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD)
3. CITY RECOMMENDS INSTALLING AT LEAST 3 CHECKDAMS WHEN USING THIS SETUP.
LIP OF GUTTER
WEIGHTED WATTLE
OR ROCK SOCK
W1 & W2 INSTALLATION NOTES:
1. THE LOCATION AND LENGTH OF WATTLE IS DEPENDENT ON THE CONDITIONS OF EACH SITE.
2. WATTLES SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES.
3. WATTLES SHALL CONSIST OF STRAW, COMPOST, EXCELSIOR, OR COCONUT FIBER.
4. NOT FOR USE IN CONCENTRATED FLOW AREAS.
5. THE WATTLES SHALL BE TRENCHED INTO THE GROUND A MINIMUM OF TWO (2) INCHES.
6. WATTLES SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
7. ON SLOPES, WATTLES SHOULD BE INSTALLED ON CONTOUR WITH A SLIGHT DOWNWARD ANGLE AT THE END OF THE ROW IN ORDER TO PREVENT PONDING AT THE MID SECTION.
8. RUNNING LENGTHS OF WATTLES SHOULD BE ABUTTED FIRMLY TO ENSURE NO LEAKAGE AT THE ABUTMENTS.
9. SPACING - DOWNSLOPE:
10. VERTICAL SPACING FOR SLOPE INSTALLATIONS SHOULD BE DETERMINED BY SITE CONDITIONS. SLOPE GRADIENT AND SOIL TYPE ARE THE MAIN FACTORS. A GOOD RULE OF THUMB IS:
1:1 SLOPES = 10 FEET APART
2:1 SLOPES = 20 FEET APART
3:1 SLOPES = 30 FEET APART
4:1 SLOPES = 40 FEET APART, ETC.
11. HOWEVER, ADJUSTMENTS MAY HAVE TO BE MADE FOR THE SOIL TYPE: FOR SOFT, LOAMY SOILS - ADJUST THE ROWS CLOSER TOGETHER; FOR HARD, ROCKY SOILS - ADJUST THE ROWS
FURTHER APART. A SECONDARY WATTLE PLACED BEHIND THE ABUTMENT OF TWO WATTLES IS ENCOURAGED ON STEEP SLOPES OR WHERE JOINTS HAVE FAILED IN THE PAST.
12. STAKING: THE CITY RECOMMENDS USING WOOD STAKES TO SECURE THE WATTLES. 1/2" TO 5/8" REBAR IS ALSO ACCEPTABLE. BE SURE TO USE A STAKE THAT IS LONG ENOUGH TO
PROTRUDE SEVERAL INCHES ABOVE THE WATTLE: 18" IS A GOOD LENGTH FOR HARD, ROCKY SOIL. FOR SOFT LOAMY SOIL USE A 24" STAKE.
4"-6" ABOVE WATTLE AFTER BAILING WIRE
OR NYLON ROPE IS ATTACHED. STAKES
NEED TO BE TAMPED UNTIL WIRE/ROPE IS
SNUG WITH WATTLE.
W3 NOTE:
IF THE AREA BEHIND THE INLET IS NOT STABILIZED, A BMP
SHOULD BE USED TO PREVENT SEDIMENT FROM ENTERING THE
INLET
1"x 1" WOOD STAKES
18"-24"
THE CONTRACTOR SHALL INSPECT WATTLES EVERY TWO WEEKS AND AFTER ANY SIGNIFICANT STORM EVENT AND MAKE REPAIRS OR REMOVE SEDIMENT ACCUMULATED BEHIND WATTLE AS NECESSARY.
SEDIMENT ACCUMULATED BEHIND WATTLE SHALL BE REMOVED WHEN THE SEDIMENT HAS ACCUMULATED TO ONE HALF THE DIAMETER OF THE WATTLE.
WATTLES SHALL REMAIN IN PLACE UNTIL THE UPSTREAM DISTURBED AREA IS STABILIZED AND IS ACCEPTED BY THE CITY.
WATTLE MAINTENANCE NOTES:
1.
2.
3.
ENDS SHALL ABUT TIGHTLY
TO BACK OF CURB AND FOLLOW
CURB FOR 1 FOOT (MIN.)
END SHALL ABUT TIGHTLY
TO BACK OF CURB AND FOLLOW
CURB FOR 1 FOOT (MIN.)
ENDS OF ADJACENT WATTLES
SHALL BE TIGHTLY ABUTTED
TO PREVENT SEDIMENT BYPASS
4' MAX.
SEDIMENT
DEPOSITION ZONE
W2 NOTE:
ONLY WATTLES MADE WITH COCONUT FIBERS
SHALL BE USED WHEN INSTALLATION COMES IN
CONTACT WITH A WATER BODY.
SIDEWALK CULVERT/CHASE/PAN
W3, W4 & W5 NOTES:
1. WHEN USING STRAW WATTLE, THE STRAW WATTLE MUST HAVE A WEIGHTED CORE.
2. ALL PRODUCTS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS.
3. OTHER PRODUCTS MAY BE USED IN PLACE OF WEIGHTED WATTLES UPON WRITTEN APPROVAL
FROM THE CITY. NOTE: A COPY OF DETAILS AND SPECIFICATIONS WILL NEED TO BE
INCORPORATED INTO THE SWMP.
END SHALL
TIGHTLY ABUT TO
BACK OF CURB
SEDIMENT
DEPOSITION ZONE
TUBULAR
MARKER
EXISTING OR
PROPOSED INLET
END SHALL
TIGHTLY ABUT TO
BACK OF CURB
EROSION CONTROL FOR CONSTRUCTION
ON INDIVIDUAL RESIDENTIAL LOTS
SWALE WATTLE DIKE DROP INLET PROTECTION
IP
1 2
4 5
3
ENDS SHALL ABUT TIGHTLY
TO BACK OF CURB AND FOLLOW
CURB FOR 1 FOOT (MIN.)
* *
2" x 2" x 10' OR 12'
12 GAUGE TELESPAR POST
(22F12A31)
2' - 3'
FROM F
Street Curb
See Figure 16-1
R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMOND
GRADE. SIGN MOUNTED TO POST WITH 1 EACH
DRIVE RIVET WITH NYLON WASHER AGAINST SIGN
FACE (ON TOP OF THE SIGN). THE BOTTOM OF THE
SIGN SHALL BE MOUNTED WITH 1 EACH
5/16"x2-1/2" HEW BOLT WITH METAL AND FROM
NYLON WASHERS (NYLON WASHER AGAINST SIGN
FACE) AND SECURED WITH 1 EACH 5/16" HEX NUT
ON THE BACK SIDE OF POST.
L
2-1/4" x 2-1/4" x 3'
ANCHOR/STUB
2 EACH 8" BLADES
MOUNTED TO POST
WITH 4 EACH DRIVE
RIVETS WITH
NYLON WASHERS
* 12 Gauge
ATTACHED SIDEWALK DETAIL
NOTE: Construct sidewalk with joints at 10' intervals
R 1/8"
WEAKENED PLANE JOINT EXPANSION JOINT
R1/4"
and aligned with scoring on curb.
INSTALL IN LOCATIONS SPECIFIED
IN CHAPTER 22
1/2"
1/4"
1/4 SLAB THICKNESS
1/4"
1/2" Expansion
Joint material
DETACHED SIDEWALK DETAIL
Variable
Landscaping
2' min.
Slope: Minumum
1
4"/ft
Maximum 3"/ft
W
ASPHALT
W W
P.C.
CROSSPAN
THICKENED
ASPHALT
THICKENED
AND WALK
CURB, GUTTER
T = THICKNESS OF CROSSPAN
W = WIDTH OF CROSSPAN
P.C.
*-If subgrade is flyash
treated, use T instead of 2T.
21.75"
R 0.13"
7"
2"
3.75"
12"
ROLL-OVER
VERTICAL
(LOVELAND)
Gutter edge may be
tapered or battered.
(Typical for all Curb &
& Gutter Types)
AGAINST THE FIRST, DO NOT OVERLAP THE ENDS. STAKE THE WATTLES AT EACH END AND
FOUR FOOT ON CENTER. FOR EXAMPLE:
A 25 FOOT WATTLE USES 6 STAKES
A 20 FOOT WATTLE USES 5 STAKES
A 12 FOOT WATTLE USES 4 STAKES
STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF THE WATTLE. LEAVING 2 - 3 INCHES
OF THE STAKE PROTRUDING ABOVE THE WATTLE. A HEAVY SEDIMENT LOAD WILL TEND TO
PICK THE WATTLE UP AND COULD PULL IT OFF THE STAKES IF THEY ARE DRIVEN DOWN TOO
LOW. IT MAY BE NECESSARY TO MAKE A HOLE IN THE WATTLE WITH A PICK END OF YOUR
MADDOX IN ORDER TO GET THE STAKE THROUGH THE STRAW. WHEN STRAW WATTLES ARE
USED FOR FLAT GROUND APPLICATIONS, DRIVE THE STAKES STRAIGHT DOWN; WHEN
INSTALLING WATTLES ON SLOPES, DRIVE THE STAKES PERPENDICULAR TO THE SLOPE.
DRIVE THE FIRST END STAKE OF THE SECOND WATTLE AT AN ANGLE TOWARD THE FIRST
WATTLE IN ORDER TO HELP ABUT THEM TIGHTLY TOGETHER. IF YOU HAVE DIFFICULTY
DRIVING THE STAKE INTO EXTREMELY HARD OR ROCKY SLOPES, A PILOT BAR MAY BE
NEEDED TO BEGIN THE STAKE HOLE.
1"x 1" WOOD STAKES
18"-24"
BAILING WIRE OR
NYLON ROPE
WATTLE "A" WATTLE "B"
1' 2'
TYP.
1' 1'
W2 NOTES:
INSTALLATION:
STAKES SHOULD BE DRIVEN ACROSS FROM EACH OTHER AND ON EACH
SIDE OF THE WATTLE. LEAVING 4"-6" OF STAKE PROTRUDING ABOVE THE
WATTLE. BAILING WIRE OR NYLON ROPE SHOULD BE TIED TO THE
STAKES ACROSS THE WATTLE. STAKES SHOULD THEN BE DRIVEN UNTIL
THE BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG TO THE
WATTLE.
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, TO PREVENT
SHIFTING, BUTT THE SECOND WATTLE TIGHTLY AGAINST THE FIRST. DO
NOT OVERLAP THE ENDS. STAKES SHOULD BE DRIVEN 1 FT. FROM END,
ACROSS FROM AND ON EACH SIDE OF WATTLE LEAVING 4"-6" OF STAKE
PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR NYLON ROPE
SHOULD BE TIED TO STAKES IN AN HOUR GLASS FORMATION (FRONT TO
BACK OF WATTLE "A", ACROSS TO FRONT OF WATTLE "B", ACROSS TO
BACK AND BACK TO FRONT OF WATTLE "A"). STAKES SHOULD THEN BE
DRIVEN IN UNTIL BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG
TO THE WATTLE.
SEDIMENT
DEPOSITION
ZONE
STORM WATER LINE
WEIGHTED WATTLE
OR ROCK SOCK
LIP OF GUTTER
SIDEWALK
EXISTING OR
PROPOSED INLET
TOP BACK CURB
FLOW LINE
SEDIMENT
DEPOSITION
ZONE
STORM WATER LINE
LIP OF GUTTER
WEIGHTED WATTLE
OR ROCK SOCK
AT 45 DEG. TO CURB
SIDEWALK
TOP BACK CURB
FLOW LINE
SIDEWALK
TOP BACK CURB
FLOW LINE
W4 NOTES:
1. NUMBER OF WATTLES AND SPACING SHOULD BE DETERMINED BY THE SLOPE AND SITE CONDITIONS.
2. TUBULAR MARKERS SHALL MEET THE REQUIREMENTS OF MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD)
3. CITY RECOMMENDS INSTALLING AT LEAST 3 CHECKDAMS WHEN USING THIS SETUP.
LIP OF GUTTER
WEIGHTED WATTLE
OR ROCK SOCK
W1 & W2 INSTALLATION NOTES:
1. THE LOCATION AND LENGTH OF WATTLE IS DEPENDENT ON THE CONDITIONS OF EACH SITE.
2. WATTLES SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES.
3. WATTLES SHALL CONSIST OF STRAW, COMPOST, EXCELSIOR, OR COCONUT FIBER.
4. NOT FOR USE IN CONCENTRATED FLOW AREAS.
5. THE WATTLES SHALL BE TRENCHED INTO THE GROUND A MINIMUM OF TWO (2) INCHES.
6. WATTLES SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
7. ON SLOPES, WATTLES SHOULD BE INSTALLED ON CONTOUR WITH A SLIGHT DOWNWARD ANGLE AT THE END OF THE ROW IN ORDER TO PREVENT PONDING AT THE MID SECTION.
8. RUNNING LENGTHS OF WATTLES SHOULD BE ABUTTED FIRMLY TO ENSURE NO LEAKAGE AT THE ABUTMENTS.
9. SPACING - DOWNSLOPE:
10. VERTICAL SPACING FOR SLOPE INSTALLATIONS SHOULD BE DETERMINED BY SITE CONDITIONS. SLOPE GRADIENT AND SOIL TYPE ARE THE MAIN FACTORS. A GOOD RULE OF THUMB IS:
1:1 SLOPES = 10 FEET APART
2:1 SLOPES = 20 FEET APART
3:1 SLOPES = 30 FEET APART
4:1 SLOPES = 40 FEET APART, ETC.
11. HOWEVER, ADJUSTMENTS MAY HAVE TO BE MADE FOR THE SOIL TYPE: FOR SOFT, LOAMY SOILS - ADJUST THE ROWS CLOSER TOGETHER; FOR HARD, ROCKY SOILS - ADJUST THE ROWS
FURTHER APART. A SECONDARY WATTLE PLACED BEHIND THE ABUTMENT OF TWO WATTLES IS ENCOURAGED ON STEEP SLOPES OR WHERE JOINTS HAVE FAILED IN THE PAST.
12. STAKING: THE CITY RECOMMENDS USING WOOD STAKES TO SECURE THE WATTLES. 1/2" TO 5/8" REBAR IS ALSO ACCEPTABLE. BE SURE TO USE A STAKE THAT IS LONG ENOUGH TO
PROTRUDE SEVERAL INCHES ABOVE THE WATTLE: 18" IS A GOOD LENGTH FOR HARD, ROCKY SOIL. FOR SOFT LOAMY SOIL USE A 24" STAKE.
4"-6" ABOVE WATTLE AFTER BAILING WIRE
OR NYLON ROPE IS ATTACHED. STAKES
NEED TO BE TAMPED UNTIL WIRE/ROPE IS
SNUG WITH WATTLE.
W3 NOTE:
IF THE AREA BEHIND THE INLET IS NOT STABILIZED, A BMP
SHOULD BE USED TO PREVENT SEDIMENT FROM ENTERING THE
INLET
1"x 1" WOOD STAKES
18"-24"
THE CONTRACTOR SHALL INSPECT WATTLES EVERY TWO WEEKS AND AFTER ANY SIGNIFICANT STORM EVENT AND MAKE REPAIRS OR REMOVE SEDIMENT ACCUMULATED BEHIND WATTLE AS NECESSARY.
SEDIMENT ACCUMULATED BEHIND WATTLE SHALL BE REMOVED WHEN THE SEDIMENT HAS ACCUMULATED TO ONE HALF THE DIAMETER OF THE WATTLE.
WATTLES SHALL REMAIN IN PLACE UNTIL THE UPSTREAM DISTURBED AREA IS STABILIZED AND IS ACCEPTED BY THE CITY.
WATTLE MAINTENANCE NOTES:
1.
2.
3.
ENDS SHALL ABUT TIGHTLY
TO BACK OF CURB AND FOLLOW
CURB FOR 1 FOOT (MIN.)
END SHALL ABUT TIGHTLY
TO BACK OF CURB AND FOLLOW
CURB FOR 1 FOOT (MIN.)
ENDS OF ADJACENT WATTLES
SHALL BE TIGHTLY ABUTTED
TO PREVENT SEDIMENT BYPASS
4' MAX.
SEDIMENT
DEPOSITION ZONE
W2 NOTE:
ONLY WATTLES MADE WITH COCONUT FIBERS
SHALL BE USED WHEN INSTALLATION COMES IN
CONTACT WITH A WATER BODY.
SIDEWALK CULVERT/CHASE/PAN
W3, W4 & W5 NOTES:
1. WHEN USING STRAW WATTLE, THE STRAW WATTLE MUST HAVE A WEIGHTED CORE.
2. ALL PRODUCTS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS.
3. OTHER PRODUCTS MAY BE USED IN PLACE OF WEIGHTED WATTLES UPON WRITTEN APPROVAL
FROM THE CITY. NOTE: A COPY OF DETAILS AND SPECIFICATIONS WILL NEED TO BE
INCORPORATED INTO THE SWMP.
END SHALL
TIGHTLY ABUT TO
BACK OF CURB
SEDIMENT
DEPOSITION ZONE
TUBULAR
MARKER
EXISTING OR
PROPOSED INLET
END SHALL
TIGHTLY ABUT TO
BACK OF CURB
SWALE WATTLE DIKE DROP INLET PROTECTION
IP
2
4 5
ENDS SHALL ABUT TIGHTLY
TO BACK OF CURB AND FOLLOW
CURB FOR 1 FOOT (MIN.)
1
VEHICLE CONTROL TRACKING PAD
VTC
3
ELCO WATER DISTRICT
DETAIL: DRAWN: DATE:
RKB 10/91
WATER MAIN
CORPORATION STOP
BRASS TAPPING SLEEVE
(SUBJECT TO DISTRICT APPROVAL)
BEDDING OF WATERMAIN-
TYPE 'K' COPPER
-ALL FITTINGS TO BE AWWA OR I.P. BY COPPER COMPRESSION
PL
SEE ELCO STANDARD BEDDING DETAIL
BEDDED IN PEA GRAVEL
6" IN ALL DIRECTIONS
ELCO WATER DISTRICT
DETAIL:
DRAWN: DATE:
ELCO WATER DISTRICT
DETAIL:
DRAWN: DATE:
ELCO WATER DISTRICT
DETAIL:
DRAWN: DATE:
A A
24 46
4 28
6 30
8 32
10 34
12 36
4 28
6 32
8 32
10 36
12 36
14 42
16 42
18 44
24 48
SEE TRENCH WIDTH TABLE BELOW
ELCO WATER DISTRICT
DETAIL: DRAWN: DATE:
ELCO WATER DISTRICT
DETAIL: DRAWN: DATE:
ELCO WATER DISTRICT
DETAIL:
DRAWN: DATE:
ELCO WATER DISTRICT
DETAIL: DRAWN: DATE:
ELCO WATER DISTRICT
DETAIL:
DRAWN: DATE:
ELCO WATER DISTRICT
DETAIL: DRAWN: DATE:
8'-0" D 8'-0"
2'-0" 2'-0"
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
VICOT WAY
9
10
9
10
0.83
0.66
0.43
M3
0.54
0.43
1.59
N2
0.61
0.49
0.18
M1
0.25
0.20
0.02
M2
0.70
0.56
0.57
M4
1.00
0.84
0.63
N3
0.92
0.74
0.85
N1
0.59
0.47
0.12
M8
0.58
0.46
0.98
O2
0.97
0.77
1.11
O3
0.51
0.40
0.06
M7
0.73
0.59
0.21
M6
0.72
0.58
1.15
M5
0.67
O4 O5
0.99
0.79
0.72
O1
O7
1.00
0.83
0.49
G6
1.00
0.81
0.42
H1
1.00
0.90
1.57
Fut-TL3
0.97
0.78
1.04
I2
Fut-TL4
1.00
0.81
0.10
I3
I7
1.00
0.80
0.17
I4
1.00
0.81
0.17
I5
Fut-H
Fut-I1
PRIVATE DRIVE EE
PRIVATE DRIVE FF
CRUSADER STREET
12''SS 12''SS 12''SS
12''SS 12''SS
59+99.82
100+00 101+00 101+28.45
90+00 91+00 92+00 93+00
94+00
95+00 95+40.92
STA 95+12.42, 0.00'
STA 95+24.92, 0.00'
I6
I5
I2
J1
I4
I3
I9
I7
Fut-TL3
2
11
PRIVATE DRIVE EE
PRIVATE DRIVE FF
CRUSADER STREET
9
10
0.28
0.22
0.08
0.71 O8
0.57
1.18
O6
0.84
0.67
0.09
O5
0.81
0.65
0.16
O4
0.62
0.77
0.30
O7
1.00
0.90
0.28
Fut-TL4
1.00
0.81
0.10
I3
1.00
0.84
0.10
I7
1.00
0.80
0.17
I4
0.25
0.20
0.48
J1
0.89
0.71
0.12
I9
1.00
0.81
0.17
I5
Fut-I2
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DR01.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
DR01
KEYMAP
DESIGN POINT
MAJOR BASIN BOUNDARY
PROPOSED BASIN BOUNDARY
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DRAINAGE SYMBOLS:
LEGEND:
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
PROPOSED RIGHT-OF-WAY
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED STORM INLET
PROPOSED LOTLINE
EASEMENT LINE
FUTURE LOTLINE
FUTURE RIGHT-OF-WAY
BASIN ID
MINOR (2-year) RUNOFF COEFFICIENT
MAJOR (100-year) RUNOFF COEFFICIENT
BASIN AREA
(ACRES)
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR 4900
4900
35
EXISTING BASIN BOUNDARY
(PER PROPOSED UTILITY PLANS
FOR EAST RIDGE SECOND FILING
DATED: 6.30.16)
Tributary Area
C2 C100
tc | 2-Year tc | 100-Year Q2 Q100
Sub-basin (acres) (min) (min) (cfs) (cfs)
K1 0.71 0.48 0.60 9.6 8.0 0.8 3.7
K2 0.77 0.52 0.65 8.7 7.3 1.0 4.5
K3 1.19 0.72 0.90 6.9 5.0 2.2 10.8
K4 1.10 0.83 1.00 5.2 5.0 2.6 11.0
K5 0.88 0.65 0.81 5.0 5.0 1.6 7.1
L1 1.32 0.76 0.95 5.3 5.0 2.8 12.5
L2 0.67 0.61 0.77 5.0 5.0 1.2 5.1
L3 0.70 0.55 0.69 8.7 7.2 0.9 4.3
L4 1.61 0.73 0.91 6.8 5.0 3.1 14.7
L5 0.90 0.71 0.88 5.0 5.0 1.8 7.9
M1 0.18 0.49 0.61 7.1 5.8 0.2 1.1
M2 0.02 0.20 0.25 6.8 6.4 0.01 0.05
M3 0.43 0.66 0.83 5.0 5.0 0.8 3.6
M4 0.57 0.56 0.70 6.9 5.1 0.8 4.0
M5 1.15 0.58 0.72 5.0 5.0 1.9 8.3
M6 0.21 0.59 0.73 6.5 5.0 0.3 1.5
M7 0.06 0.40 0.51 5.0 5.0 0.1 0.3
M8 0.12 0.47 0.59 5.9 5.0 0.2 0.7
N1 0.85 0.74 0.92 6.1 5.0 1.7 7.8
N2 1.59 0.43 0.54 10.8 9.3 1.5 6.9
N3 0.63 0.84 1.00 5.0 5.0 1.5 6.3
O1 0.72 0.79 0.99 5.3 5.0 1.6 7.1
O2 0.98 0.46 0.58 12.1 11.0 0.9 4.3
O3 1.11 0.77 0.97 6.7 5.0 2.3 10.8
O4 0.16 0.65 0.81 5.3 5.0 0.3 1.3
O5 0.09 0.67 0.84 5.1 5.0 0.2 0.8
O6 1.18 0.57 0.71 9.5 7.9 1.5 7.3
O7 0.30 0.62 0.77 5.7 5.0 0.5 2.3
O8 0.08 0.22 0.28 6.0 5.6 0.0 0.2
OS1 0.54 0.34 0.43 12.1 12.1 0.4 1.7
OS2 0.13 0.20 0.25 5.0 5.0 0.1 0.3
OS3 0.35 0.20 0.25 5.0 5.0 0.2 0.9
OS4 0.40 0.20 0.25 5.0 5.0 0.2 1.0
OS5 0.38 0.20 0.25 5.0 5.0 0.2 1.0
DR02
( IN FEET )
1 inch = ft.
60Feet 0 60
60
120 180
DEVELOPED RUNOFF TABLE
DRAINAGE NOTES
PROPOSED AREA INLET
PROPOSED VALLEY PAN INLET(S) - NEENAH R-3362-L
EXISTING STORM DRAIN A (CONSTRUCTED W/EAST RIDGE SECOND FILING)
EXISTING STORM DRAIN B (CONSTRUCTED W/EAST RIDGE SECOND FILING)
EXISTING STORM DRAIN C (CONSTRUCTED W/EAST RIDGE SECOND FILING)
EXISTING STORM DRAIN D (CONSTRUCTED W/EAST RIDGE SECOND FILING)
CONNECT TO EXISTING STORM DRAIN IN EAST RIDGE SECOND FILING
PROPOSED SWALE w/SOFT BOTTOM PAN (TYP. FOR SWALES w/LONGITUDINAL SLOPE
OF LESS THAN 2.0%)
TYPE 'R' INLET - LENGTH VARIES
NO. 16 INLET - LENGTH VARIES
IRRIGATION LINE
MATCHLINE-SEE THIS SHEET
MATCHLINE-SEE THIS SHEET
ROTATION: 0°
YEAGER STREET
MARQUISE STREET
VINE DRIVE
PROPOSED UTILITY PLANS FOR: EAST
RIDGE SECOND FILING
DATED: 6.30.16
10
9
10
0.60
0.48
0.71
K1
0.65
0.52
0.77
K2
0.81
0.65
0.88
K5
0.90
0.72
1.19
K3
0.69
0.55
0.70
L3
0.91
0.73
1.61
L4
0.88
0.71
0.90
L5
0.77
0.61
0.67
L2
0.95
0.76
1.32
L1
0.43
0.34
0.54
OS1
0.25
0.20
0.13
OS2
0.25
0.20
0.35
OS3
0.25
0.20
0.40
OS4
0.25
0.20
0.38
OS5
Fut-A
A1
B1
A2 A3
B2
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_DR01.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
60Feet 0 60
60
120 180
KEYMAP
DESIGN POINT
MAJOR BASIN BOUNDARY
PROPOSED BASIN BOUNDARY
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DRAINAGE SYMBOLS:
LEGEND:
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
PROPOSED RIGHT-OF-WAY
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED STORM INLET
PROPOSED LOTLINE
EASEMENT LINE
FUTURE LOTLINE
FUTURE RIGHT-OF-WAY
BASIN ID
MINOR (2-year) RUNOFF COEFFICIENT
MAJOR (100-year) RUNOFF COEFFICIENT
BASIN AREA
(ACRES)
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR 4900
4900
35
EXISTING BASIN BOUNDARY
(PER PROPOSED UTILITY PLANS
FOR EAST RIDGE SECOND FILING
DATED: 6.30.16)
DRAINAGE NOTES
PROPOSED AREA INLET
PROPOSED VALLEY PAN INLET(S) - NEENAH R-3362-L
EXISTING STORM DRAIN A (CONSTRUCTED W/EAST RIDGE SECOND FILING)
EXISTING STORM DRAIN B (CONSTRUCTED W/EAST RIDGE SECOND FILING)
EXISTING STORM DRAIN C (CONSTRUCTED W/EAST RIDGE SECOND FILING)
EXISTING STORM DRAIN D (CONSTRUCTED W/EAST RIDGE SECOND FILING)
CONNECT TO EXISTING STORM DRAIN IN EAST RIDGE SECOND FILING
PROPOSED SWALE w/SOFT BOTTOM PAN (TYP. FOR SWALES w/LONGITUDINAL SLOPE
OF LESS THAN 2.0%)
TYPE 'R' INLET - LENGTH VARIES
NO. 16 INLET - LENGTH VARIES
DR01
DR02
Tributary Area
C2 C
100
tc | 2-Year tc | 100-Year Q
2 Q100
Sub-basin (acres) (min) (min) (cfs) (cfs)
K1 0.71 0.48 0.60 9.6 8.0 0.8 3.7
K2 0.77 0.52 0.65 8.7 7.3 1.0 4.5
K3 1.19 0.72 0.90 6.9 5.0 2.2 10.8
K4 1.10 0.83 1.00 5.2 5.0 2.6 11.0
K5 0.88 0.65 0.81 5.0 5.0 1.6 7.1
L1 1.32 0.76 0.95 5.3 5.0 2.8 12.5
L2 0.67 0.61 0.77 5.0 5.0 1.2 5.1
L3 0.70 0.55 0.69 8.7 7.2 0.9 4.3
L4 1.61 0.73 0.91 6.8 5.0 3.1 14.7
L5 0.90 0.71 0.88 5.0 5.0 1.8 7.9
M1 0.18 0.49 0.61 7.1 5.8 0.2 1.1
M2 0.02 0.20 0.25 6.8 6.4 0.01 0.05
M3 0.43 0.66 0.83 5.0 5.0 0.8 3.6
M4 0.57 0.56 0.70 6.9 5.1 0.8 4.0
M5 1.15 0.58 0.72 5.0 5.0 1.9 8.3
M6 0.21 0.59 0.73 6.5 5.0 0.3 1.5
M7 0.06 0.40 0.51 5.0 5.0 0.1 0.3
M8 0.12 0.47 0.59 5.9 5.0 0.2 0.7
N1 0.85 0.74 0.92 6.1 5.0 1.7 7.8
N2 1.59 0.43 0.54 10.8 9.3 1.5 6.9
N3 0.63 0.84 1.00 5.0 5.0 1.5 6.3
O1 0.72 0.79 0.99 5.3 5.0 1.6 7.1
O2 0.98 0.46 0.58 12.1 11.0 0.9 4.3
O3 1.11 0.77 0.97 6.7 5.0 2.3 10.8
O4 0.16 0.65 0.81 5.3 5.0 0.3 1.3
O5 0.09 0.67 0.84 5.1 5.0 0.2 0.8
O6 1.18 0.57 0.71 9.5 7.9 1.5 7.3
O7 0.30 0.62 0.77 5.7 5.0 0.5 2.3
O8 0.08 0.22 0.28 6.0 5.6 0.0 0.2
OS1 0.54 0.34 0.43 12.1 12.1 0.4 1.7
OS2 0.13 0.20 0.25 5.0 5.0 0.1 0.3
OS3 0.35 0.20 0.25 5.0 5.0 0.2 0.9
OS4 0.40 0.20 0.25 5.0 5.0 0.2 1.0
OS5 0.38 0.20 0.25 5.0 5.0 0.2 1.0
ROTATION: 0°
Stormwater Quality
Strategy/Detention Tributary Basins
Tributary Area
WS Elev. (Event Noted) Volume Release Rate
acres ac-ft cfs
1 - Bioswale A Basins (Includes: Fut-A) 21.92 N/A N/A N/A
2 - Sand Filter (SF) B, E and F Basins (Includes: Fut-B) 37.46 WQ=4933.96 0.75 N/A
4 - Extended Detention Basin (EDB) G and H Basins (Includes: Fut-G, Fut-H and Fut-TL2) 30.61 WQ=4931.59 0.94 40-Hour Drain Time
5 - Sand Filter (SF) I Basins (Includes Fut-I and Fut-TL3) 14.28 WQ=4930.36 0.33 N/A
7 - Detention Pond | 2-Year Site 153.29 2year=4929.28 2.43 5
7 - Detention Pond | 100-Year Site 153.29 100year=4935.89 35.41 5
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
ROTATION: 90°
1. THIS EROSION CONTROL PLAN AND ASSOCIATED SWMP ARE LIVING DOCUMENTS REQUIRING PERIODIC
REVIEW AND UPDATING AS SITE CONDITIONS CHANGE OR AS REQUIRED BY LOCAL AUTHORITIES. IT IS
THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ONGOING COMPLIANCE WITH THE REQUIREMENTS
OF THE STORMWATER DISCHARGE PERMIT.
2. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN
SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND
UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
3. EROSION CONTROL PRACTICES, SITE PROTECTION AND REVEGETATION METHODS SHALL FOLLOW
CITY OF FORT COLLINS REGULATIONS.
4. DURING CONSTRUCTION PHASING, INSTALL EROSION CONTROL MEASURES FOLLOWING BMPS WITH
EACH PHASE, AS REQUIRED.
5. PERIMETER PROTECTION (I.E., STRAW WATTLES) IS SHOWN AROUND EACH BLOCK THAT IS A PART OF
THE PROPOSED IMPROVEMENTS. REFER TO THE LEGEND (SEE RIGHT). THIS PERIMETER PROTECTION
SHALL BE INSTALLED WHEN CURB, GUTTER AND SIDEWALK INSTALLATION IS COMPLETED IN THE
ADJOINING RIGHT-OF-WAY.
6. FOLLOWING OVERLOT GRADING OR ANY OTHER LAND DISTURBING ACTIVITY, ALL OTHER AREAS OF
THE SITE TO BE DEVELOPED DURING LATER PHASES OF CONSTRUCTION AND WHICH SHALL REMAIN
EXPOSED FOR MORE THAN THIRTY-(30) DAYS WILL REQUIRE TEMPORARY OR PERMANENT EROSION
CONTROL (I.E., SEED/MULCH, LANDSCAPING, ETC.).
7. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON SEEDING/PLANTING, REVEGETATION,
EROSION FABRIC/BLANKETS, IRRIGATION, HARDSCAPE AND OTHER TEMPORARY AND PERMANENT
SITE STABILIZATION METHODS.
8. SEE EROSION CONTROL NOTES ON THIS SHEET AND GRADING & EROSION CONTROL NOTES ON SHEET
CV02, AS WELL AS DETAILS ON SHEETS DT09-DT11.
GENERAL NOTES:
EXISTING STORM SEWER
PROPOSED STORM SEWER
VEHICLE TRACKING CONTROL PAD
SILT FENCE
PLANTED RIPRAP PROTECTION
INLET PROTECTION
CONCRETE WASHOUT AREA
NOTE:
ALL BMPs SHOWN ARE GRAPHICAL IN NATURE. FINAL SIZE
AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR.
OUTLET PROTECTION
STABILIZED STAGING AREA
STOCKPILE MANAGEMENT
ROCK SOCK
PROPERTY BOUNDARY
SF
OP
IP
CWA
SSA
SP
VTC
RS
RP
LEGEND: PERMANENT BMPs
TEMPORARY BMPs
PROPOSED SWALE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED CURB AND GUTTER
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
4552
4550
PROPOSED MINOR CONTOUR 4900
PROPOSED MAJOR CONTOUR
PROPOSED STORM INLET
44
PROPOSED MANHOLE
SF SF
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
KEYMAP
EC01
DR02
MATCHLINE-SEE THIS SHEET
MATCHLINE-SEE THIS SHEET
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE
UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE
CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR
PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT
ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT
INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
MATCHLINE-SEE THIS SHEET
ROTATION: 0°
1. THIS EROSION CONTROL PLAN AND ASSOCIATED SWMP ARE LIVING DOCUMENTS REQUIRING PERIODIC
REVIEW AND UPDATING AS SITE CONDITIONS CHANGE OR AS REQUIRED BY LOCAL AUTHORITIES. IT IS
THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ONGOING COMPLIANCE WITH THE REQUIREMENTS
OF THE STORMWATER DISCHARGE PERMIT.
2. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN
SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND
UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
3. EROSION CONTROL PRACTICES, SITE PROTECTION AND REVEGETATION METHODS SHALL FOLLOW
CITY OF FORT COLLINS REGULATIONS.
4. DURING CONSTRUCTION PHASING, INSTALL EROSION CONTROL MEASURES FOLLOWING BMPS WITH
EACH PHASE, AS REQUIRED.
5. PERIMETER PROTECTION (I.E., STRAW WATTLES) IS SHOWN AROUND EACH BLOCK THAT IS A PART OF
THE PROPOSED IMPROVEMENTS. REFER TO THE LEGEND (SEE RIGHT). THIS PERIMETER PROTECTION
SHALL BE INSTALLED WHEN CURB, GUTTER AND SIDEWALK INSTALLATION IS COMPLETED IN THE
ADJOINING RIGHT-OF-WAY.
6. FOLLOWING OVERLOT GRADING OR ANY OTHER LAND DISTURBING ACTIVITY, ALL OTHER AREAS OF
THE SITE TO BE DEVELOPED DURING LATER PHASES OF CONSTRUCTION AND WHICH SHALL REMAIN
EXPOSED FOR MORE THAN THIRTY-(30) DAYS WILL REQUIRE TEMPORARY OR PERMANENT EROSION
CONTROL (I.E., SEED/MULCH, LANDSCAPING, ETC.).
7. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON SEEDING/PLANTING, REVEGETATION,
EROSION FABRIC/BLANKETS, IRRIGATION, HARDSCAPE AND OTHER TEMPORARY AND PERMANENT
SITE STABILIZATION METHODS.
8. SEE EROSION CONTROL NOTES ON THIS SHEET AND GRADING & EROSION CONTROL NOTES ON SHEET
CV02, AS WELL AS DETAILS ON SHEETS DT09-DT11.
GENERAL NOTES:
EXISTING STORM SEWER
PROPOSED STORM SEWER
VEHICLE TRACKING CONTROL PAD
SILT FENCE
PLANTED RIPRAP PROTECTION
INLET PROTECTION
CONCRETE WASHOUT AREA
NOTE:
ALL BMPs SHOWN ARE GRAPHICAL IN NATURE. FINAL SIZE
AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR.
OUTLET PROTECTION
STABILIZED STAGING AREA
STOCKPILE MANAGEMENT
ROCK SOCK
PROPERTY BOUNDARY
SF
OP
IP
CWA
SSA
SP
VTC
RS
RP
LEGEND:
PERMANENT BMPs
TEMPORARY BMPs
PROPOSED SWALE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED CURB AND GUTTER
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
4552
4550
PROPOSED MINOR CONTOUR 4900
PROPOSED MAJOR CONTOUR
PROPOSED STORM INLET
44
PROPOSED MANHOLE
SF SF
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
RD09
ROTATION: 90°
LEGEND:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED LOT LINE
EASEMENT LINE
1.BOUNDARY ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL PROJECT
NOTES ON THE COVER SHEET OF THESE PLANS, AS WELL
AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION
NOTES LISTED HERE.
2. ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS,
STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC.
3. ALL SIGNAGE SHALL BE PER LOCAL ENTITY STANDARDS
AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD.
4. ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE
TWO COATS OF LATEX PAINT WITH GLASS BEADS.
5. ALL LANE LINES FOR CONCRETE PAVEMENT SHOULD BE
EPOXY PAINT.
6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING
AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY
TABS OR TAPE DEPICTING ALIGNMENT AND PLACEMENT OF
THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE
LOCAL ENTITY ENGINEER PRIOR TO PERMANENT
INSTALLATION OF STRIPING AND SYMBOLS.
7. PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS
SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS.
8. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN
CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION.
9. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO
INSTALLATION OF STRIPING OR MARKINGS.
10. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES
AND FASTENERS PER THE STANDARDS.
11. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF
ALL SIGNS SHALL BE PERFORMED BY THE LOCAL ENTITY
ENGINEER. ALL DISCREPANCIES IDENTIFIED DURING THE
FIELD INSPECTION MUST BE CORRECTED BEFORE THE
2-YEAR WARRANTY PERIOD WILL BEGIN.
12. THE DEVELOPER INSTALLING SIGNS SHALL BE
RESPONSIBLE FOR LOCATING AND PROTECTING ALL
UNDERGROUND UTILITIES.
13. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO
ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN.
14. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY
INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR
TO INITIATION OF THE WARRANTY PERIOD, THE LOCAL
ENTITY ENGINEER RESERVES THE RIGHT TO REQUIRE
ADDITIONAL SIGNAGE AND/OR STRIPING IF THE LOCAL
ENTITY ENGINEER DETERMINES THAT AN UNFORESEEN
CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE
MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE
AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF
THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION
(EXCEPT FAIR WEAR ON TRAFFIC MARKINGS).
15. SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN
ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC
CONTROL DEVICES, FOR ADDITIONAL DETAIL.
SIGN INDEX: TRAFFIC SIGNING AND PAVEMENT MARKING CONSTRUCTION NOTES
1 R1-1 STOP SIGN (30"x 30")
2 STREET NAME SIGN
3
4
R2-1 SPEED LIMIT SIGN (SEE NOTE THIS SHEET)
R2-5P UNLESS OTHERWISE POSTED SIGN
NOTES:
1. ALL POSTED SPEED LIMITS ARE 25
MPH UNLESS OTHERWISE POSTED.
5 R7-1 NO PARKING ANY TIME SIGN
6 R4-7 KEEP RIGHT SIGN
7 R11-2 ROAD CLOSED SIGN
8 W16-9P AHEAD SIGN
9 TYPE 3 BARRICADE
10 W14-2 NO OUTLET SIGN
R11-50 EMERGENCY AND AUTHORIZED
VEHICLES ONLY SIGN
11
12 PRIVATE DRIVE ONLY SIGN
13 PRIVATE DRIVE ONLY SIGN
14 EMERGENCY ACCESS GATE
CONTRACTOR SHALL PROVIDE STEEL POST ACCESS
GATE WITH KNOX PADLOCK FOR POUDRE FIRE
AUTHORITY (PFA) EMERGENCY ACCESS ONLY. PRIOR
TO ORDERING THE STEEL POST ACCESS GATE THE
CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND
SPECIFICATIONS TO PFA AND GALLOWAY FOR REVIEW
AND APPROVAL.
15 FIRE LANE NO PARKING SIGN
RD10
BLOCK 1
BLOCK 1
TRACT C TRACT D
PROPOSED
24" PRIVATE
STORM DRAIN
1
2
1
2
1
2
10
1 12
15 15
15 15
15
15
1 13
13
1
5
5
LOT 4 LOT 1 LOT 2
LOT 3 LOT 4
LOT 5 LOT 7 LOT 8
LOT 6 LOT 9 LOT 10
LOT 11 LOT 12 LOT 13 LOT 14
HELLDIVER DRIVE (PRIVATE DRIVE)
PRIVATE DRIVE D
PRIVATE DRIVE C
BARNSTORMER STREET
VINE DRIVE
BURLINGTON NORTHERN RAILROAD
PROPOSED UTILITY PLANS FOR:
EAST RIDGE SECOND FILING
DATED : 6.30.16
LOT 36
LOT 40 LOT 41 LOT 42
LOT 43 LOT 44 LOT 45 LOT 46 LOT 47 LOT 48
LOT 49 LOT 50 LOT 51 LOT 52
LOT 54 LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60
LOT 96
LOT 100
LOT 101
LOT 102
LOT
103
LOT 104
LOT 105
LOT 106
LOT 107 LOT
108
LOT 109 LOT 110
LOT 111
LOT 112
LOT 113
LOT 114
LOT
115
LOT 116
LOT 117
LOT 118
LOT 119
LOT 120
TRACT A
TRACT B
BLOCK 1
BLOCK 1
TRACT E
9
15
15
15
15 10
13
1
1 12 13
2
1
1
LOT 37 LOT 38 LOT 39
LOT 98
LOT 97 LOT 99
RAISED CROSSWALK, SIGAGE
AND MARKINGS PER
LCUASS DETAIL 1801F
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD09.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE
UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE
CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR
PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT
ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT
INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
MATCHLINE-SEE THIS SHEET
RD09
RD10
ROTATION: 0°
MATCHLINE-SEE THIS SHEET
LEGEND:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED LOT LINE
EASEMENT LINE
PROJECT BOUNDARY
1. ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF
THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES
LISTED HERE.
2. ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE
PRE-FORMED THERMO-PLASTIC.
3. ALL SIGNAGE SHALL BE PER LOCAL ENTITY STANDARDS AND THESE PLANS OR AS
OTHERWISE SPECIFIED IN MUTCD.
4. ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH
GLASS BEADS.
5. ALL LANE LINES FOR CONCRETE PAVEMENT SHOULD BE EPOXY PAINT.
6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER
SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMENT AND PLACEMENT OF THE
SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE LOCAL ENTITY ENGINEER PRIOR TO
PERMANENT INSTALLATION OF STRIPING AND SYMBOLS.
7. PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS
AND/OR THESE STANDARDS.
8. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS
FOR ROAD AND BRIDGE CONSTRUCTION.
9. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR
MARKINGS.
10. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE
STANDARDS.
11. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED
BY THE LOCAL ENTITY ENGINEER. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD
INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN.
12. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND
PROTECTING ALL UNDERGROUND UTILITIES.
13. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF
EACH SIGN.
14. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME
OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD, THE LOCAL ENTITY ENGINEER
RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE LOCAL
ENTITY ENGINEER DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH
SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND
STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR
NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS).
15. SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO
CHAPTER 14, TRAFFIC CONTROL DEVICES, FOR ADDITIONAL DETAIL.
TRAFFIC SIGNING AND PAVEMENT MARKING CONSTRUCTION NOTES
SIGN INDEX:
1 R1-1 STOP SIGN (30"x 30")
2 STREET NAME SIGN
3
4
R2-1 SPEED LIMIT SIGN (SEE NOTE THIS SHEET)
R2-5P UNLESS OTHERWISE POSTED SIGN
NOTES:
1. ALL POSTED SPEED LIMITS ARE 25 MPH UNLESS OTHERWISE POSTED.
5 R7-1 NO PARKING ANY TIME SIGN
6 R4-7 KEEP RIGHT SIGN
7 R11-2 ROAD CLOSED SIGN
8 W16-9P AHEAD SIGN
9 TYPE 3 BARRICADE
10 W14-2 NO OUTLET SIGN
R11-50 EMERGENCY AND AUTHORIZED
VEHICLES ONLY SIGN
11
12 PRIVATE DRIVE ONLY SIGN
13 PRIVATE DRIVE ONLY SIGN
14 EMERGENCY ACCESS GATE
CONTRACTOR SHALL PROVIDE STEEL POST ACCESS
GATE WITH KNOX PADLOCK FOR POUDRE FIRE
AUTHORITY (PFA) EMERGENCY ACCESS ONLY. PRIOR
TO ORDERING THE STEEL POST ACCESS GATE THE
CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND
SPECIFICATIONS TO PFA AND GALLOWAY FOR REVIEW
AND APPROVAL.
15 FIRE LANE NO PARKING SIGN
-0.60%
0.60%
-2.00%
-8.33%
8.33%
2.41%
-0.60%
-0.50%
0.50%
0.60%
STA: 90+00.00
ELEV=4942.81
STA: 94+86.49
ELEV=4942.06
STA: 95+12.42
ELEV=4942.22
STA: 95+16.92
ELEV=4942.13
STA: 95+22.92
ELEV=4941.63
STA: 95+40.92
ELEV=4942.18
STA: 91+14.02
ELEV=4942.12
STA: 91+39.02
ELEV=4942.00
STA: 91+64.02
ELEV=4942.12
HP STA:93+20.18
HP ELEV:4942.99
PVI STA:93+20.18
PVI ELEV:4943.1
K:41.67
LVC:50.00
BVCS:92+95.18
BVCE:4942.91
EVCS:93+45.18
EVCE:4942.91
(4943.8)
4942.81
(4944.6)
4942.21
(4945.1)
4942.34
(4945.1)
4942.94
(4944.6)
4942.58
(4942.2)
4942.15
(4944.4)
4942.51
(4944.8)
4942.05
(4945.2)
4942.64
(4945.1)
4942.88
(4943.0)
4942.28
PROPOSED
GRADE
EXISTING
GROUND
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
ROTATION: 0°
STA:
SCALE: H: 1"= V: 1"=
PRIVATE DRIVE FF to
CENTERLINE
100+00.00 101+10.45
50 5
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD08_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
STA:
SCALE: H: 1"= V: 1"=
PRIVATE DRIVE EE to
CENTERLINE
90+00.00 95+40.92
50 5
RD08
ROTATION: 90°
R20' R25'
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
STA:
SCALE: H: 1"= V: 1"=
VIGILANTE LANE to
CENTERLINE
80+00.00 81+80.25
50 5
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD06_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
RD07
ROTATION: 0°
4935
4940
4945
4950
4955
59+50 60+00 61+00 62+00 63+00 64+00 65+00
-8.33%
8.33%
2.25%
0.80%
-1.00%
-0.50%
0.55%
-2.52%
-2.00%
STA: 60+00.00
ELEV=4945.53
STA: 64+18.43
ELEV=4944.20
STA: 64+36.43
ELEV=4944.73
STA: 61+66.90
ELEV=4944.65
STA: 61+91.90
ELEV=4944.53
STA: 64+07.93
ELEV=4944.79
STA: 64+12.43
ELEV=4944.70
HP STA:63+61.86
HP ELEV:4945.43
PVI STA:63+77.93
PVI ELEV:4945.5
K:16.30
LVC:50.00
BVCS:63+52.93
BVCE:4945.41
EVCS:64+02.93
EVCE:4944.92
HP STA:60+41.01
HP ELEV:4945.77
PVI STA:60+43.79
PVI ELEV:4945.9
K:27.78
LVC:50.00
BVCS:60+18.79
BVCE:4945.68
EVCS:60+68.79
EVCE:4945.63
(4946.8)
4945.53
(4946.3)
4945.32
(4945.8)
4944.57
(4945.1)
4945.12
(4944.9)
4944.99
(4946.5)
4945.76
(4946.1)
4944.82
(4945.5)
4944.85
(4945.0)
4945.39
PROPOSED
GRADE
EXISTING
GROUND
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
STA:
SCALE: H: 1"= V: 1"=
COMET STREET to
CENTERLINE
70+00.00 70+91.86
50 5
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD06_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
STA:
SCALE: H: 1"= V: 1"=
THUNDERSTREAK LANE to
CENTERLINE
60+00.00 64+20.77
50 5
RD06
RD06
ROTATION: 0°
0.52%
0.50%
0.80%
-0.80%
-0.50%
-0.80%
-0.50%
0.50%
0.80%
STA: 50+00.00
ELEV=4946.21
STA: 58+70.82
ELEV=4943.38
STA: 58+95.82
ELEV=4943.26
STA: 59+20.82
ELEV=4943.38
STA: 59+99.82
ELEV=4943.79
STA: 55+60.84
ELEV=4945.41
STA: 55+10.84
ELEV=4945.41
STA: 55+35.84
ELEV=4945.29
STA: 51+34.72
ELEV=4945.13
STA: 51+59.72
ELEV=4945.01
STA: 51+84.72
ELEV=4945.13
HP STA:53+65.10
HP ELEV:4946.46
PVI STA:53+65.10
PVI ELEV:4946.6
K:37.50
LVC:60.00
BVCS:53+35.10
BVCE:4946.34
EVCS:53+95.10
EVCE:4946.34
HP STA:55+88.88
HP ELEV:4945.54
PVI STA:55+88.88
PVI ELEV:4945.6
K:31.25
LVC:50.00
BVCS:55+63.88
BVCE:4945.44
EVCS:56+13.88
EVCE:4945.44
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
STA:
SCALE: H: 1"= V: 1"=
SKYRAIDER WAY to
CENTERLINE
30+00.00 31+21.50
50 5
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD05_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
RD05
ROTATION: 90°
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD03_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
PRIVATE DRIVE D to
CENTERLINE
40+00.00 41+83.01
50 5
ROTATION: 90°
RD04
4965
32+00 31+00 30+00 29+50
-2.39%
-8.33%
8.33%
2.00%
-1.48%
STA: 30+00.00
ELEV=4951.05
STA: 30+15.00
ELEV=4950.57
STA: 30+22.00
ELEV=4951.16
STA: 30+27.00
ELEV=4951.26
STA: 31+34.13
ELEV=4950.19
HP STA:30+40.96
HP ELEV:4951.30
PVI STA:30+52.00
PVI ELEV:4951.4
K:24.33
LVC:50.00
BVCS:30+27.00
BVCE:4951.26
EVCS:30+77.00
EVCE:4951.03
(4951.1)
4951.05
(4950.7)
4950.69
(4951.3)
4951.28
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD03_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
PRIVATE DRIVE B to
CENTERLINE
20+00.00 21+21.50
50 5
ROTATION: 90°
STA:
SCALE: H: 1"= V: 1"=
PRIVATE DRIVE C to
CENTERLINE
30+00.00 31+21.50
50 5
RD03 RD03
4950
4955
4960
4965
18+50 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00
0.50%
0.80%
0.50%
-0.80%
-0.50%
-0.80%
-0.50%
0.80%
1.20%
STA: 22+29.52
ELEV=4950.19
STA: 22+54.52
ELEV=4950.07
STA: 22+79.52
ELEV=4950.19
STA: 25+85.73
ELEV=4951.68
STA: 26+10.73
ELEV=4951.56
STA: 26+35.73
ELEV=4951.68
STA: 29+10.00
ELEV=4953.88
STA: 29+50.76
ELEV=4954.37
HP STA:19+57.64
HP ELEV:4952.27
PVI STA:19+57.64
PVI ELEV:4952.4
K:31.25
LVC:50.00
BVCS:19+32.64
BVCE:4952.17
EVCS:19+82.64
EVCE:4952.17
HP STA:25+25.77
HP ELEV:4952.06
PVI STA:25+25.77
PVI ELEV:4952.2
K:31.25
LVC:50.00
BVCS:25+00.77
BVCE:4951.96
EVCS:25+50.77
EVCE:4951.96
(4952.5)
4951.91
(4952.9)
4952.03
(4952.3)
4951.23
(4951.6)
4950.43
(4951.4)
4950.36
(4952.0)
4951.16
(4952.6)
4951.96
(4953.2)
4951.61
(4953.8)
4952.20
(4954.4)
4953.00
(4955.4)
4953.80
(4952.9)
4952.26
(4952.6)
4951.63
(4952.0)
4950.83
(4951.4)
4950.09
(4951.7)
4950.76
(4952.3)
4951.56
(4952.9)
4951.97
(4953.5)
4951.80
(4954.1)
4952.60
(4954.8)
4953.40
(4957.6)
4954.36
PROPOSED
GRADE
EXISTING
GROUND
0.80%
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD01_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
HELLDIVER DRIVE to
CENTERLINE
18+50.00 29+50.76
50 5
MATCH LINE SEE SHEET: RD01 STA:
18+50.00
ROTATION: 0°
RD01 RD02
9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 18+50
-2.21%
-8.33%
8.33%
2.00%
-0.80%
-0.50%
0.50%
0.80%
0.50%
0.80%
-0.80%
-0.50%
STA: 10+00.00
ELEV=4950.77
STA: 10+15.00
ELEV=4950.31
STA: 10+22.07
ELEV=4950.90
STA: 10+26.50
ELEV=4950.99
STA: 12+83.30
ELEV=4949.33
STA: 13+08.30
ELEV=4949.21
STA: 13+33.30
ELEV=4949.33
STA: 16+77.32
ELEV=4950.12
STA: 16+27.32
ELEV=4950.12
STA: 16+52.32
ELEV=4950.00
HP STA:10+51.50
HP ELEV:4951.09
PVI STA:10+51.50
PVI ELEV:4951.2
K:31.25
LVC:50.00
BVCS:10+26.50
BVCE:4950.99
EVCS:10+76.50
EVCE:4950.99
HP STA:15+29.71
HP ELEV:4950.81
PVI STA:15+29.71
PVI ELEV:4950.9
K:31.25
LVC:50.00
BVCS:15+04.71
BVCE:4950.71
EVCS:15+54.71
EVCE:4950.71
(4950.8)
4950.77
(4950.7)
4950.80
(4950.5)
4950.00
(4949.5)
4949.25
(4948.4)
4949.87
(4949.4)
4950.67
(4950.2)
4950.34
(4951.0)
4950.31
(4951.8)
4951.11
(4950.8)
4951.09
(4951.0)
4950.40
(4950.0)
4949.60
(4948.9)
4949.47
(4948.8)
4950.27
(4949.8)
4950.74
(4950.6)
4950.01
(4951.4)
4950.71
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_RD01_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
HELLDIVER DRIVE to
CENTERLINE
10+00.00 18+50.00
50 5
MATCH LINE SEE SHEET: RD02 STA: 18+50.00
ROTATION: 0°
RD01 RD02
@
0.40%
STA=140+00.00
EXMH D11
8'Ø MH
TBC=4948.96
INV IN (12" W)=4940.34
DEPTH=8.62
PROPOSED
GRADE
EXISTING
GROUND
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
131+00 130+00 129+50
STA=130+48.29
INLET G
2' ROUND AREA INLET
TBC=4947.90
INV OUT (12" NE)=4941.35
DEPTH=6.55
44.14 LF - 12''
PVC @ 0.40%
STA=130+00.00
EX INLET D12
TRIPLE TYPE 13 COMBO INLET
TBC=4949.69
INV IN (12" SW)=4941.17
DEPTH=8.51
PROPOSED
GRADE
EXISTING
GROUND
4915
4920
4925
4930
4935
4940
4945
4950
4915
4920
4925
4930
4935
4940
4945
4950
161+50 161+00 160+00 159+00
STA=160+00.00
EX INLET F
6' DOUBLE TYPE 16 COMBO INLET
TBC=4941.73
INV OUT (18" W)=4934.09
DEPTH=7.63
21.00 LF - 18'' RCP @ -0.40%
STA=160+21.00
SDMH F1
4'Ø MH
TBC=4942.78
INV IN (18" E)=4934.18
INV OUT (18" S)=4934.18
DEPTH=8.61
83.15 LF - 18'' RCP @ -0.40%
STA=161+04.15
INLET F2
CDOT TYPE C INLET
TBC=4942.06
INV IN (18" N)=4934.51
DEPTH=7.55
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD09_S.dwg - Andrea McDaniel - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN E to
CENTERLINE
130+00.00 130+13.02
50 5
ROTATION: 0°
SD10
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN H to
CENTERLINE
140+00.00 140+22.25
50 5
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN G to
CENTERLINE
130+00 130+48.29
50 5
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN F to
CENTERLINE
160+00.00 160+04.15
160+04.05 5
RIM=4947.23
INV IN (18" S)=4936.94
INV OUT (18" N)=4936.74
DEPTH=10.50
24.97 LF
- 18''
RCP @
0.40%
STA=90+57.50
INLET D8.2
2' ROUND AREA INLET
RIM=4946.43
INV IN (18" S)=4937.04
INV OUT (18" N)=4937.04
DEPTH=9.39
4925
4930
4935
4940
4945
4950
4955
4925
4930
4935
4940
4945
4950
4955
79+50 80+00 81+00 81+50
STA=51+59.10
SDMH D3
4'Ø FLAT TOP MH
RIM=4946.48
INV IN (24" W)=4935.16
INV IN (18" N)=4935.96
INV OUT (30" E)=4934.96
DEPTH=11.52
92.00 LF - 18'' RCP @ 0.40%
STA=80+92.00
INLET D3.1
CDOT TYPE C INLET
RIM=4944.53
INV OUT (18" S)=4936.33
DEPTH=8.20
4925
4930
4935
4940
4945
4950
4955
4925
4930
4935
4940
4945
4950
4955
71+50 71+00 70+00 69+50
STA=50+54.83
SDMH D1
6'Ø FLAT TOP MH
RIM=4945.96
INV IN (30" W)=4934.05
INV IN (18" SW)=4935.05
INV OUT (30" E)=4933.85
DEPTH=12.12
59.37 LF - 18'' RCP @
4.00%
STA=???
INLET D2.1
CDOT TYPE C INLET
RIM=4942.53
INV OUT (18" NE)=4937.42
DEPTH=5.11
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD05_S.dwg - Kyle Pollock - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN D8 to
CENTERLINE
39+50.00 46+00.00
50 5
ROTATION: 0°
SD08
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN D3 to
CENTERLINE
39+50.00 46+00.00
50 5
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN D1 to
CENTERLINE
39+50.00 46+00.00
50 5
TBC=4946.99
INV IN (24" W)=4935.97
INV OUT (24" E)=4935.77
DEPTH=11.22
66.53 LF - 24'' RCP @ 0.40%
STA=53+77.13
INLET D6
CDOT TYPE C INLET
TBC=4945.01
INV IN (18" NW)=4936.74
INV OUT (24" E)=4936.24
DEPTH=8.77
20.03 LF -
18'' RCP
@ 0.40%
STA=53+98.55
SDMH D7
4'Ø FLAT TOP MH
TBC=4945.93
INV IN (18" W)=4936.82
INV OUT (18" SE)=4936.82
DEPTH=9.11
72.25 LF - 18'' RCP @ 0.40%
STA=54+70.80
SDMH D8
4'Ø FLAT TOP MH
TBC=4946.74
INV IN (18" N)=4937.10
INV IN (18" S)=4936.61
INV OUT (18" E)=4937.11
DEPTH=10.13
149.27 LF - 18'' RCP @ 0.40%
STA=56+20.07
SDMH D9
4'Ø FLAT TOP MH
TBC=4947.78
INV OUT (18" S)=4937.69
DEPTH=10.09
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD05_S.dwg - Kyle Pollock - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
TIMBERLINE ROAD
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
ROTATION: 0°
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN D to
CENTERLINE
19+50.00 22+00.00
50 5
SD07
4920
4925
4930
4935
4940
4945
4950
4955
4920
4925
4930
4935
4940
4945
4950
4955
67+50 67+00 66+00 65+00 64+50
STA=66+03.03
INLET C6.1
2' ROUND AREA INLET
TBC=4946.54
INV IN (18" N)=4936.09
INV OUT (18" S)=4936.09
DEPTH=10.45
34.34 LF -
18'' RCP
@ 0.40%
STA=45+87.07
SDMH C6
4'Ø FLAT TOP MH
TBC=4946.37
INV IN (18" W)=4935.68
INV IN (18" N)=4935.68
INV OUT (24" S)=4935.18
DEPTH=11.19
103.03 LF - 18'' RCP @ 0.40%
STA=66+37.37
SDMH C6.2
4'Ø FLAT TOP MH
TBC=4946.90
INV IN (18" W)=4936.23
INV OUT (18" S)=4936.23
DEPTH=10.67
92.00 LF - 18'' RCP @ 0.40%
STA=67+29.37
INLET C6.3
CDOT TYPE C INLET
TBC=4945.29
INV OUT (18" E)=4936.59
DEPTH=8.69
PROPOSED
GRADE
EXISTING
GROUND
4920
4925
4930
4935
4940
4945
4950
4955
4920
4925
4930
4935
4940
4945
4950
4955
119+50 120+00 121+00 122+00
STA=121+17.64
INLET C7.4
2' ROUND AREA INLET
TBC=4944.64
INV OUT (18" N)=4937.16
DEPTH=7.48
34.75 LF -
18'' RCP
@ 0.50%
STA=120+82.89
INLET C7.3
2' ROUND AREA INLET
TBC=4945.46
INV IN (18" S)=4936.99
INV OUT (18" N)=4936.99
DEPTH=8.47
24.98 LF -
18'' RCP
@ 0.50%
STA=120+57.92
INLET C7.2
2' ROUND AREA INLET
TBC=4944.72
INV IN (18" S)=4936.86
INV OUT (18" N)=4936.86
DEPTH=7.86
24.98 LF -
18'' RCP
@ 0.50%
STA=120+32.94
INLET C7.1
2' ROUND AREA INLET
TBC=4945.66
INV IN (18" S)=4936.74
INV OUT (18" N)=4936.74
DEPTH=8.93
32.94 LF -
18'' RCP
@ 0.40%
STA=47+68.82
SDMH C7
4'Ø FLAT TOP MH
TBC=4945.86
INV IN (18" N)=4936.60
INV IN (18" S)=4936.60
INV OUT (18" E)=4936.40
DEPTH=9.45
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD03_S.dwg - Kyle Pollock - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
STORM C5 to
CENTERLINE
39+50.00 46+00.00
50 5
ROTATION: 0°
SD06
STA:
SCALE: H: 1"= V: 1"=
STORM C6 to
CENTERLINE
39+50.00 46+00.00
50 5
ROTATION: 90°
STA:
SCALE: H: 1"= V: 1"=
STORM C7 to
CENTERLINE
39+50.00 46+00.00
50 5
ROTATION: 90°
@ 0.40%
STA=40+00.00
EXMH C
6'Ø MH
TBC=4941.64
DEPTH=8.33
165.94 LF - 42'' RCP @ 0.40%
STA=41+65.94
EXMH C1
8'Ø MH
TBC=4941.44
INV IN (36" N)=4933.97
INV OUT (42" E)=4933.97
DEPTH=7.47
STA=41+74.44
EX INLET C2
15' CDOT TYPE R INLET
TBC=4941.64
INV IN (30" N)=4934.01
INV OUT (36" S)=4934.01
DEPTH=7.63
123.00 LF - 30'' RCP @ 0.20%
STA=42+97.44
INLET C3
CDOT TYPE C INLET
TBC=4943.12
INV IN (24" N)=4934.25
INV OUT (30" S)=4934.25
DEPTH=8.86
47.01 LF - 24''
RCP @ 0.20%
STA=43+44.45
INLET C4
6'Ø FLAT TOP MH
TBC=4944.10
INV IN (24" E)=4934.35
INV OUT (24" S)=4934.35
DEPTH=9.75
67.00 LF - 24'' RCP @
0.20%
STA=60+00.00 (STORM C5)
STA=44+11.45 STORM C
SDMH C5
6'Ø FLAT TOP MH
RIM=4945.11
INV IN (24" N)=4934.48
INV IN (18" E)=4934.98
INV OUT (24" W)=4934.48
DEPTH=10.63
175.61 LF - 24'' RCP @ 0.40%
STA=65+00.00 (STORM C6)
STA=45+87.07 STORM C
SDMH C6
4'Ø FLAT TOP MH
RIM=4946.37
INV IN (18" W)=4935.68
INV IN (18" N)=4935.68
INV OUT (24" S)=4935.18
DEPTH=11.19
181.75 LF - 18'' RCP @ 0.40%
STA=120+00.00 (STORM C7)
STA=47+68.82 STORM C
SDMH C7
4'Ø FLAT TOP MH
RIM=4945.86
INV IN (18" N)=4936.60
INV IN (18" S)=4936.60
INV OUT (18" E)=4936.40
DEPTH=9.45
STA=49+22.80
INLET C12
2' ROUND AREA INLET
RIM=4946.52
INV IN (18" N)=4937.22
INV OUT (18" S)=4937.22
DEPTH=9.30
STA=50+96.39
INLET C16
2' ROUND AREA INLET
RIM=4947.54
INV OUT (18" S)=4937.92
DEPTH=9.62
PROPOSED
GRADE
EXISTING
GROUND
8.50 LF - 36'' RCP @ 0.40%
STA=47+92.53
INLET C8
2' ROUND AREA INLET
RIM=4945.13
INV IN (18" N)=4936.70
INV OUT (18" S)=4936.70
DEPTH=8.43
45.56 LF -
18'' RCP
@ 0.40%
STA=48+38.08
INLET C9
2' ROUND AREA INLET
RIM=4945.58
INV IN (18" N)=4936.88
INV OUT (18" S)=4936.88
DEPTH=8.69
34.76 LF -
18'' RCP
@ 0.40%
STA=48+72.84
INLET C10
2' ROUND AREA INLET
RIM=4946.41
INV IN (18" N)=4937.02
INV OUT (18" S)=4937.02
DEPTH=9.39
24.98 LF -
18'' RCP
@ 0.40%
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD03_S.dwg - Kyle Pollock - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
TIMBERLINE ROAD
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
ROTATION: 90°
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN C to
40+00.00 50+96.39
50 5
SD06
4935
4940
4945
4950
4955
4960
122+00 121+00 120+00 119+50
STA=35+86.50 (STORM B)
STA=120+00.00 STORM B5
INLET B5
CDOT TYPE C INLET
RIM=4951.89
INV IN (18" S)=4944.97
INV IN (18" E)=4945.47
INV OUT (24" W)=4944.97
DEPTH=6.92
61.30 LF - 18'' RCP @
0.50%
PROPOSED
GRADE
EXISTING
GROUND
STA=120+61.30
INLET B5.1
2' ROUND AREA INLET
RIM=4952.08
INV IN (18" S)=4945.27
INV OUT (18" N)=4945.27
DEPTH=6.81
42.85 LF - 18'' RCP @ 0.50%
STA=121+04.15
INLET B5.2
CDOT TYPE C INLET
RIM=4951.56
INV OUT (18" N)=4945.49
DEPTH=6.07
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD01_N.dwg - Kyle Pollock - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN B3 to
110+00.00 111+98.76
50 5
ROTATION: 0°
SS02
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN B5 to
120+00.00 121+04.15
50 5
ROTATION: 90°
EX INLET B
TRIPLE TYPE 13 COMBO INLET
RIM=4950.99
INV IN (42" N)=4941.39
DEPTH=9.60
25.02 LF -
42'' RCP
@ 0.50%
STA=30+24.37
INLET B1
5' CDOT TYPE R INLET
RIM=4951.29
INV IN (30" N)=4941.66
INV OUT (42" S)=4941.52
DEPTH=9.77
101.23 LF - 30'' RCP @ 0.50%
STA=31+25.59
INLET B2
CDOT TYPE C INLET
RIM=4950.10
INV IN (24" N)=4942.66
INV OUT (30" S)=4942.16
DEPTH=7.93
100.12 LF - 24'' RCP @ 0.50%
STA=110+00.00 (STORM B3)
STA=32+25.71 STORM B
INLET B3
CDOT TYPE C INLET
RIM=4949.92
INV IN (24" E)=4943.16
INV IN (18" W)=4943.66
INV OUT (24" S)=4943.16
DEPTH=6.76
STA=120+00.00 (STORM B5)
STA=35+86.50 STORM B
INLET B5
CDOT TYPE C INLET
RIM=4951.89
INV IN (18" S)=4944.97
INV IN (18" E)=4945.47
INV OUT (24" W)=4944.97
DEPTH=6.92
150.28 LF - 12'' RCP @ 0.50%
STA=38+83.97
INLET B7
2' ROUND AREA INLET
TBC=4954.62
INV OUT (12" W)=4947.46
DEPTH=7.16
STA=37+33.69
INLET B6
2' ROUND AREA INLET
TBC=4953.09
INV IN (12" E)=4946.70
INV OUT (18" W)=4946.20
DEPTH=6.88
147.19 LF - 18'' RCP @ 0.50%
188.12 LF - 24'' RCP @ 0.50%
STA=33+98.38
INLET B4
2' ROUND AREA INLET
TBC=4951.46
INV IN (24" E)=4944.03
INV OUT (24" W)=4944.03
DEPTH=7.43
172.67 LF - 24'' RCP @ 0.50%
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD01_N.dwg - Kyle Pollock - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN B to
30+00.00 38+83.97
50 5
ROTATION: 0°
SS02
INLET A1.3
2' ROUND AREA INLET
RIM=4952.87
INV IN (18" E)=4943.92
INV OUT (18" S)=4943.72
DEPTH=9.16
STA=25+84.47
INLET A1.4
2' ROUND AREA INLET
TBC=4951.54
INV OUT (18" W)=4944.94
DEPTH=6.60
205.01 LF - 18'' RCP @ 0.50%
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD01_N.dwg - Kyle Pollock - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
TIMBERLINE ROAD
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
SD01
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN A1 to
20+00.00 25+84.47
50 5
ROTATION: 0°
7'Ø MH
RIM=4950.35
INV IN (24" W)=4941.12
INV IN (24" E)=4941.12
INV OUT (42" S)=4939.62
DEPTH=10.73
PROPOSED
GRADE
EXISTING
GROUND
32.66 LF -
18'' RCP @
0.50%
STA=14+06.32
INLET A4
2' ROUND AREA INLET
RIM=4950.08
INV IN (18" N)=4943.64
INV OUT (18" S)=4943.64
DEPTH=6.45
RACT A
E SECOND FILING
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''W
HELLDIVER DRIVE
BARNSTORMER STREET
TRACT A
BLOCK 1
TRACT B
BLOCK 1
TRACT C
ACT M
LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12
LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT
LOT 61 LOT 62 LOT 63 LOT 64 LOT 65 LOT 66
LOT 67 LOT 68 LOT 69 LOT 70 LOT 71 LOT 72
LOT 73 LOT 74 LOT 75 LOT 76 LOT 77 LOT 7
16+01.53
10+00
12+00 11+00
13+00 14+00
16+00 15+00
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
18''SS 18''SS 18''SS 18''SS 18''SS 18''SS
8''W
8''W
18''SS 18''SS 18''SS 18''SS 18''SS
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
89+50 90+00 91+00 92+00
STA=14+38.97 (STORM A)
STA=90+00.00 STORM A5
INLET A5
2' ROUND AREA INLET
RIM=4952.26
INV IN (18" W)=4943.99
INV IN (18" E)=4943.99
INV OUT (18" S)=4943.80
DEPTH=8.46
STA=23+75.71
INLET A5.1
2' ROUND AREA INLET
TBC=4950.27
INV OUT (18" W)=4944.64
DEPTH=5.63
129.62 LF - 18'' RCP @ 0.50%
PROPOSED
GRADE
EXISTING
GROUND
8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS 8''SS
TRACT A
BLOCK 1
TRACT B
OT 5 LOT 6
LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12
LOT 1
14+00
15+00
90+00 91+00 91+29.62
18''SS 18''SS 18''SS
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SD01_N.dwg - Kyle Pollock - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
TIMBERLINE ROAD
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
ROTATION: 0°
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN A to
9+50.00 16+50.00
50 5
SD01
STA:
SCALE: H: 1"= V: 1"=
STORM DRAIN A5 to
90+00.00 91+50
50 5
STA=90+00.00 SANITARY 4.3
SSMH 4.3
4'Ø MH
RIM=4946.23
INV IN (8" N)=4933.33
INV IN (8" E)=4933.33
INV OUT (8" S)=4933.13
DEPTH=13.10
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SS02_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
TIMBERLINE ROAD
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER LINE 4.3 to
10+00.00 18+50.00
50 5
ROTATION: 0°
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER LINE 4.1 to
10+00.00 18+50.00
50 5
SS05
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SS02_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
TIMBERLINE ROAD
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER LINE 4 to
69+50.00 81+00.00
50 5
ROTATION: 90°
SS05
DEPTH=9.58
STA=53+12.30
SSMH 3.2
4'Ø MH
RIM=4945.86
INV OUT (8" E)=4936.14
DEPTH=9.72
173.71 LF - 8'' PVC @ 0.40% 138.59 LF - 8'' P
VC @ 0.40%
STA=50+00.00
EXMH 3
4'Ø MH
RIM=4945.76
INV IN (8" S)=4934.70
DEPTH=11.06
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SS02_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER LINE 3.1 to
60+00.00 62+00.00
50 5
ROTATION: 0°
ROTATION: 0°
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER LINE 3 to
CENTERLINE
49+50.00 53+50.00
50 5
SS04
LOT 79 LOT 80 LOT 81 LOT 82 LOT 83 LOT 84
LOT 85 LOT 86 LOT 87 LOT 88 LOT 89 LOT 90
LOT 91 LOT 92 LOT 93 LOT 94 LOT 95 LOT 96
LOT 97 LOT 98 LOT 99
STA. 45+36.3
STA. 45+33.3
STA. 45+16.3
STA. 45+13.3
STA. 44+96.3
STA. 44+93.3
STA. 44+76.3
STA. 44+73.3
STA. 44+56.3
STA. 44+53.3
STA. 44+36.3
STA. 44+33.3
STA. 43+76.5
STA. 43+73.5
STA. 43+56.5
STA. 43+53.5
STA. 43+36.5
STA. 43+33.5
STA. 43+16.5
STA. 43+13.5
STA. 42+96.5
STA. 42+93.5
STA. 42+76.5
STA. 42+73.5
STA. 42+21.3
STA. 42+18.3
STA. 42+01.3
STA. 41+98.3
STA. 41+81.3
STA. 41+78.3
STA. 41+61.3
STA. 41+58.3
STA. 41+41.3
STA. 41+38.3
STA. 41+21.3
STA. 41+18.3
20' EOA-EOA
32' UTILITY, DRAINAGE, ACCESS,
EMERGENCY ACCESS EASEMENT
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
S
BARNSTORMER STREET
HELLDIVER DRIVE
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
46+00 45+00 44+00 43+00 42+00 41+00 40+00 39+50
STA=40+00.00 (SANITARY 2.1)
STA=40+00.00 SANITARY 2.1
SSMH 2.1
4'Ø MH
RIM=4950.32
INV IN (8" E)=4938.66
INV IN (8" W)=4938.66
INV OUT (8" S)=4938.46
DEPTH=11.87
51.18 LF - 8'' PVC
@ 0.50%
STA=40+51.18
SSMH 2.1-1
4'Ø MH
RIM=4950.32
INV IN (8" W)=4939.11
INV OUT (8" E)=4938.91
DEPTH=11.41
245.89 LF - 8'' PVC @ 0.50%
STA=42+97.08
SSMH 2.1-2
4'Ø MH
RIM=4952.25
INV IN (8" W)=4940.54
INV OUT (8" E)=4940.34
DEPTH=11.91
245.89 LF - 8'' PVC @ 0.50%
STA=45+42.97
SSMH 2.1-3
4'Ø MH
RIM=4950.74
INV OUT (8" E)=4941.77
DEPTH=8.97
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SS01_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER LINE 2.1 to
39+50.00 46+00.00
50 5
ROTATION: 0°
SS03
30+00 31+00
32+00 33+00 34+00 35+00 36+00 37+00 37+60.61
TRACT A
TRACT B
BLOCK 1
BLOCK 1
TRACT E
LOT 37 LOT 38 LOT 39 LOT 40 LOT 41 LOT 42
LOT 43 LOT 44 LOT 45 LOT 46 LOT 47 LOT 48
LOT 49 LOT 50 LOT 51 LOT 52 LOT 53 LOT 54
LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60
LOT 97 LOT 98 LOT 99 LOT 100 LOT 101 LOT 102
LOT 103 LOT 104 LOT 105 LOT 106 LOT 107 LOT 108
LOT 109 LOT 110 LOT 111 LOT 112 LOT 113 LOT 114
LOT 115 LOT 116 LOT 117 LOT 118 LOT 119 LOT 120
STA. 31+66.4
STA. 31+72.5
STA. 31+86.4
STA. 31+92.5
STA. 32+06.4
STA. 32+12.5
STA. 32+26.4
STA. 32+32.5
STA. 32+46.4
STA. 32+52.5
STA. 32+66.4
STA. 32+72.5
STA. 33+31.5
STA. 33+37.5
STA. 33+51.5
STA. 33+57.5
STA. 33+71.5
STA. 33+77.5
STA. 33+91.5
STA. 33+97.5
STA. 34+11.5
STA. 34+17.5
STA. 34+31.5
STA. 34+37.5
STA. 34+96.4
STA. 35+02.4
STA. 35+16.4
STA. 35+22.4
STA. 35+36.4
STA. 35+42.5
STA. 35+56.4
STA. 35+62.4
STA. 35+76.4
STA. 35+82.4
STA. 35+96.4
STA. 36+02.4
STA. 36+50.5
STA. 36+53.5
STA. 36+70.5
STA. 36+73.5
STA. 36+90.5
STA. 36+93.5
STA. 37+10.5
STA. 37+13.5
STA. 37+30.5
STA. 37+33.5
STA. 37+50.5
STA. 37+53.5
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
S
4925
4930
4935
4940
4945
4950
4955
4960
4965
4925
4930
4935
4940
4945
4950
4955
4960
4965
29+50 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00
STA=40+00.00 (SANITARY 2.1)
STA=31+38.50 SANITARY 2
SSMH 2.1
4'Ø MH
RIM=4950.32
INV IN (8" E)=4938.66
INV IN (8" W)=4938.66
INV OUT (8" S)=4938.46
DEPTH=11.87
STA=30+00.00
EXMH 2
4'Ø MH
RIM=4951.07
INV IN (8" N)=4937.76
INV IN (8" E)=4937.76
INV OUT (8" W)=4937.56
DEPTH=13.51
138.50 LF - 8'' PVC @ 0.50% 311.06 LF - 8
'' PVC @ 0.50%
STA=34+49.56
SSMH 2.2
4'Ø MH
RIM=4951.75
INV IN (8" E)=4940.41
INV OUT (8" W)=4940.21
DEPTH=11.54
311.06 LF - 8'' PVC @ 0.50%
STA=37+60.61
SSMH 2.3
4'Ø MH
RIM=4953.95
INV OUT (8" W)=4941.97
DEPTH=11.98
PROPOSED
GRADE
EXISTING
GROUND
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SS01_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER 2 to
30+00.00 37+60.61
50 5
ROTATION: 0°
SS02
STA. 12+11.5
STA. 12+28.5
STA. 12+31.5
STA. 12+48.5
STA. 12+51.5
STA. 12+68.5
STA. 12+71.5
STA. 12+88.5
STA. 12+91.5
W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS
8''W
8''W
18''SS 18''SS 18''SS 18''SS 18''SS
HELLDIVER DRIVE
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
9+50 10+00 11+00 12+00 13+00 13+50
STA=13+05.08
SSMH 1.1
4'Ø MH
RIM=4950.43
INV OUT (8" W)=4938.20
DEPTH=12.23
305.08 LF - 8'' HDPE @ 0.50%
STA=10+00.00
EXMH 1
4'Ø MH
RIM=4949.37
INV IN (18" N)=4935.84
INV IN (8" W)=4936.67
INV IN (8" E)=4936.67
INV OUT (18" S)=4935.64
DEPTH=13.73
PROPOSED
GRADE
EXISTING
GROUND
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
22+00 21+00 20+00 19+50
STA=20+00.00
EXMH 1
4'Ø MH
RIM=4949.37
INV IN (18" N)=4935.84
INV IN (8" W)=4936.67
INV IN (8" E)=4936.67
INV OUT (18" S)=4935.64
DEPTH=13.73
137.00 LF - 8'' HDPE @ 0.50%
STA=21+37.00
SSMH 1A
4'Ø MH
RIM=4950.42
INV OUT (8" E)=4937.36
DEPTH=13.06
PROPOSED
GRADE
EXISTING
GROUND
G
8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS
S S S S S S
S S S S S S
S
S
S
S
BARNSTORMER STREET
21+37 21+00 20+00
TRACT C
LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT 7 LOT 8
LOT 61 LOT 62 LOT 63 LOT 64 LOT 65 LOT 66
LOT 67 LOT 68
STA. 21+30.1
STA. 21+27.1
STA. 21+07.1
STA. 21+10.1
STA. 20+90.1
STA. 20+87.1
STA. 20+70.1
STA. 20+67.1
STA. 20+50.0
STA. 20+47.1
STA. 20+30.1
STA. 20+27.1
12''W 12''W 12''W 12''W 12''W
18''SS
8''W
18''SS 18''SS 18''SS 18''SS 18''SS
HELLDIVER DRIVE
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_SS01_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
KEYMAP
TIMBERLINE ROAD
EXISTING EDGE OF ASPHALT
PROPOSED CONCRETE
CROSSPAN (TYP.)
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO
VERIFY EXACT UTILITY LOCATION.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS.
3. CONTRACTOR SHALL ADJUST EXISTING SANITARY AND STORM SEWER MANHOLES AND SUBDRAIN
CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE
ADJUSTED TO1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL EXTENT OF STREET CUT TO BE DETERMINED IN THE FIELD
BY THE CITY ENGINEERING INSPECTOR. REPAIRS SHALL BE PER THE LATEST CITY STANDARDS.
5. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET.
6. SEE SHEET CV01 FOR TYPICAL SECTIONS.
7. ELEVATIONS ARE TO FLOWLINE OF CURB AND GUTTER OR RIGHT-OF-WAY UNLESS OTHERWISE NOTED.
8. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS
4900 FEET (4948.71 = 4948.71).
9. MATCHLINES ARE BASED ON CENTERLINE ALIGNMENTS.
LEGEND:
NOTES:
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED RIGHT-OF-WAY
PROPOSED BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
PROPOSED STORM SEWER
PROPOSED STORM INLET
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
(33.45)
33.45
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER LINE 1 to
9+50.00 13+50.00
50 5
ROTATION: 0°
STA:
SCALE: H: 1"= V: 1"=
SANITARY SEWER LINE 1A to
19+50.00 22+00.00
50 5
SS01
EXISTING TELEPHONE
EXISTING GAS
PROPOSED SEWER SERVICE S
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED WATER SERVICE/METER
PROPOSED FIRE HYDRANT
PROPOSED LOTLINE
EASEMENT LINE
PROPERTY BOUNDARY
PROPOSED ELECTRIC
W 8"
PROPOSED 8" SANITARY SEWER SS 8"
PROPOSED WATER LOWERING
PROPOSED MANHOLE
SS 8"
12" W
GAS
LEGEND:
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN
APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO
CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO
ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION.
2. WATER SERVICE PROVIDED BY EAST LARIMER COUNTY (ELCO) WATER DISTRICT. WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION.
3. SEWER SERVICE PROVIDED BY BOXELDER SANITATION DISTRICT. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION.
4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 4.5' AND MAXIMUM COVER SHALL BE 5.5' UNLESS OTHERWISE NOTED.
5. SANITARY SEWER SERVICES SHALL BE SDR-35 PVC AND WATER MAINS SHALL BE AWWA C-900 PVC.
6. ALL WATER FITTINGS AND VALVES ARE ARE NOT TO SCALE AND ARE ONLY GRAPHICALLY REPRESENTED.
7. UTILITY SERVICES SHOWN ARE SCHEMATIC ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
8. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
9. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
10. THE LIMITS OF STREET CUT ARE APPROXIMATE. FINAL STREET CUT LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE PER THE CITY STREET REPAIR
STANDARDS.
11. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
12. SEE SHEET EX02 & EX03 FOR EXISTING BOUNDARY CORNER COORDINATES.
13. ATTACHED SINGLE FAMILY DWELLINGS WILL REQUIRE A RESIDENTIAL SPRINKLER SYSTEM.
14. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN.
15. WATER SERVICE LINES WITH LESS THAN 1-FT OF CLEARANCE AT STORM DRAIN CROSSING AND WITH LESS THAN 4.5-FT OF COVER SHALL BE INSTALLED BELOW THE STORM DRAIN AND IN 1-1/2" (MIN.)
DIAMETER HDPE SLEEVE.
NOTES:
EXISTING WATER MAIN 8" W
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_UT03_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
UT01 UT02
UT03
ROTATION: 90°
UT04
EXISTING TELEPHONE
EXISTING GAS
PROPOSED SEWER SERVICE S
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED WATER SERVICE/METER
PROPOSED FIRE HYDRANT
PROPOSED LOTLINE
EASEMENT LINE
PROPERTY BOUNDARY
PROPOSED ELECTRIC
W 8"
PROPOSED 8" SANITARY SEWER SS 8"
PROPOSED WATER LOWERING
PROPOSED MANHOLE
SS 8"
12" W
GAS
LEGEND:
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN
APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO
CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO
ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION.
2. WATER SERVICE PROVIDED BY EAST LARIMER COUNTY (ELCO) WATER DISTRICT. WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION.
3. SEWER SERVICE PROVIDED BY BOXELDER SANITATION DISTRICT. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION.
4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 4.5' AND MAXIMUM COVER SHALL BE 5.5' UNLESS OTHERWISE NOTED.
5. SANITARY SEWER SERVICES SHALL BE SDR-35 PVC AND WATER MAINS SHALL BE AWWA C-900 PVC.
6. ALL WATER FITTINGS AND VALVES ARE ARE NOT TO SCALE AND ARE ONLY GRAPHICALLY REPRESENTED.
7. UTILITY SERVICES SHOWN ARE SCHEMATIC ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
8. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
9. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
10. THE LIMITS OF STREET CUT ARE APPROXIMATE. FINAL STREET CUT LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE PER THE CITY STREET REPAIR
STANDARDS.
11. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
12. SEE SHEET EX02 & EX03 FOR EXISTING BOUNDARY CORNER COORDINATES.
13. ATTACHED SINGLE FAMILY DWELLINGS WILL REQUIRE A RESIDENTIAL SPRINKLER SYSTEM.
14. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN.
15. WATER SERVICE LINES WITH LESS THAN 1-FT OF CLEARANCE AT STORM DRAIN CROSSING AND WITH LESS THAN 4.5-FT OF COVER SHALL BE INSTALLED BELOW THE STORM DRAIN AND IN 1-1/2" (MIN.)
DIAMETER HDPE SLEEVE.
NOTES:
EXISTING WATER MAIN 8" W
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_UT03_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
UT01 UT02
UT03
ROTATION: 90°
UT04
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W
12''W 12''W
8''SS8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
S
LOT 4
LOT 5
LOT 1 LOT 2
LOT 3 LOT 4
LOT 5
LOT 29 LOT 28 LOT 27
LOT 31 LOT 30 LOT 25
LOT 7 LOT 8 LOT 9
LOT 24 LOT 23
LOT 6
LOT 26
LOT 10 LOT 11 LOT 12 LOT 13 LOT 14
LOT 19
LOT 22 LOT 21 LOT 20
LOT 18
LOT 17
LOT 4 LOT 1 LOT 2
LOT 3 LOT 4 LOT 5 LOT 6 LOT 7
LOT 8 LOT 9 LOT 10
LOT 11
BLOCK 21
BLOCK 19
(UNPLATTED)
OWNER: WHITHAM FARMS LLC
REC. NO. 20010120159
45° BEND w/TB
N: 19746.27
E: 12568.91
45° BEND w/TB
N: 19734.83
E: 12580.23
8"x6" SWIVEL TEE w/TB
1 - 6" G.V. (N)
N: 19749.87
E: 11922.34
FIRE HYDRANT
ASSEMBLY
N: 19767.07
E: 11922.44
8"x6" SWIVEL TEE w/TB
1 - 6" G.V. (S)
1 - 8" G.V. (W)
N: 19748.16
E: 12230.26
FIRE HYDRANT
ASSEMBLY
N: 19740.66
E: 12230.22
8"x6" SWIVEL TEE w/TB
1 - 6" G.V. (S)
1 - 8" G.V. (E)
N: 19746.43
E: 12543.31
FIRE HYDRANT
ASSEMBLY
N: 19739.33
E: 12543.28
REMOVE EXISTING CAP
CONNECT TO
EXISTING STUB
N: 19652.98
E: 11901.80
REMOVE EXISTING CAP
CONNECT TO
EXISTING STUB
N: 19649.21
E: 12579.75
8"x8" TEE w/TB
3 - 8" G.V. (S, E,W)
N: 19749.98
E: 11902.34
HELLDIVER DRIVE (PRIVATE DRIVE)
PRIVATE DRIVE D
PRIVATE DRIVE C
32.41 LF 8" PVC
S67°10'53"E
14.00 LF 8" PVC
S89°46'43"E
20.00 LF 8" PVC
S89°40'53"E
303.65 LF 8" PVC
S89°40'37"E
97.00 LF 8" PVC
N00°19'07"E
PROPOSED 8"
SANITARY LINE
BARNSTORMER STREET
BIPLANE STREET
VINE DRIVE
50' RAILROAD RIGHT OF WAY
BOOK 245, PAGE 76
& REC. NO. 99035876
BURLINGTON NORTHERN RAILROAD
TRACT B 20' UTILITY, DRAINAGE,
ACCESS AND EMERGENCY ACCESS
6' UTILITY
EASEMENT
6' UTILITY
EASEMENT
PROPOSED UTILITY PLANS FOR:
EAST RIDGE SECOND FILING
DATED : 6.30.16
313.05 LF 8" PVC
S89°41'00"E
LOT 36
LOT 40 LOT 41 LOT 42
LOT 43 LOT 44 LOT 45 LOT 46 LOT 47 LOT 48
LOT 49 LOT 50 LOT 51 LOT 52
LOT 54 LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60
LOT 96
LOT 100
LOT 101
LOT 102
LOT
103
LOT 104
LOT 105
LOT 106
LOT 107 LOT
108
LOT 109 LOT 110
LOT 111
LOT 112
LOT 113
LOT 114
LOT
115
LOT 116
LOT 117
LOT 118
LOT 119
LOT 120
25.61 LF 8" PVC
S89°39'23"E
16.10 LF 8" PVC
S44°40'53"E
85.62 LF 8" PVC
S00°19'38"W
TRACT A
TRACT B
BLOCK 1
BLOCK 1
TRACT E
22.5° BEND w/TB
N: 19750.04
E: 11892.62
22.5° BEND w/TB
N: 19762.60
E: 11862.75
PROPOSED
30" PRIVATE
STORM DRAIN
STORM DRAIN B
SEE SHEET SD03
STORM DRAIN B5
SEE SHEET SD04
SANITARY LINE 2
SEE SHEET SS02
STORM DRAIN B
SEE SHEET SD03
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_UT01-02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
PROPOSED RIGHT-OF-WAY
EXISTING WATER MAIN
PROPOSED 8" WATER MAIN
PROPOSED STORM SEWER
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
PROPOSED SEWER SERVICE S
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED WATER SERVICE/METER
PROPOSED FIRE HYDRANT
PROPOSED LOTLINE
EASEMENT LINE
PROPERTY BOUNDARY
PROPOSED ELECTRIC
W 8"
PROPOSED 8" SANITARY SEWER SS 8"
PROPOSED WATER LOWERING
PROPOSED MANHOLE
SS 8"
12" W
GAS
LEGEND:
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN
APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO
CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO
ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION.
2. WATER SERVICE PROVIDED BY EAST LARIMER COUNTY (ELCO) WATER DISTRICT. WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION.
3. SEWER SERVICE PROVIDED BY BOXELDER SANITATION DISTRICT. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION.
4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 4.5' AND MAXIMUM COVER SHALL BE 5.5' UNLESS OTHERWISE NOTED.
5. SANITARY SEWER SERVICES SHALL BE SDR-35 PVC AND WATER MAINS SHALL BE AWWA C-900 PVC.
6. ALL WATER FITTINGS AND VALVES ARE ARE NOT TO SCALE AND ARE ONLY GRAPHICALLY REPRESENTED.
7. UTILITY SERVICES SHOWN ARE SCHEMATIC ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
8. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
9. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
10. THE LIMITS OF STREET CUT ARE APPROXIMATE. FINAL STREET CUT LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE PER THE CITY STREET REPAIR
STANDARDS.
11. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
12. SEE SHEET EX02 & EX03 FOR EXISTING BOUNDARY CORNER COORDINATES.
13. ATTACHED SINGLE FAMILY DWELLINGS WILL REQUIRE A RESIDENTIAL SPRINKLER SYSTEM.
14. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN.
15. WATER SERVICE LINES WITH LESS THAN 1-FT OF CLEARANCE AT STORM DRAIN CROSSING AND WITH LESS THAN 4.5-FT OF COVER SHALL BE INSTALLED BELOW THE STORM DRAIN AND IN 1-1/2" (MIN.)
DIAMETER HDPE SLEEVE.
NOTES:
EXISTING WATER MAIN 8" W
MATCHLINE-SEE SHEET UT01
UT01 UT02
UT03
ROTATION: 0°
UT04
S
S
S
S
S
S
S
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
18''SS 18''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8
''SS 8''SS 8''SS 8''SS 8''SS
12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W 12''W 12''W 12''W 12''W 12''W
18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 12''W 12''W 12''W 12''W 12''W
8''W 8''W 12''W 12''W 12''W 12''W 12''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS 8''SS
8''SS 8''SS 8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W
18''SS 18''SS 18''SS 18''SS 18''SS
S
S
18''SS 18''SS 18''SS 18''SS 18''SS
LOT 1
LOT 2
LOT 16 LOT 1
LOT 15
LOT 3 LOT 14
LOT 4 LOT 13
LOT 5 LOT 12
LOT 6 LOT 11
LOT 6 LOT 13
LOT 5
LOT 14
LOT 4 LOT 15
LOT 3 LOT 16
LOT 2 LOT 17
LOT 18
LOT 2 LOT 3 LOT 4
LOT 5 LOT 6
LOT 13 LOT 12 LOT 11 LOT 10
LOT 1
LOT 14
LOT 7
LOT 9 LOT 8
LOT 1 LOT 3 LOT 4 LOT 5
LOT 2 LOT 6 LOT 7
LOT 2 LOT 3 LOT 4
LOT 7 LOT 6 LOT 5
LOT 1
LOT 8
LOT 2 LOT 3 LOT 4
LOT 1
BLOCK 7
BLOCK 8
BLOCK 9
BLOCK 9
BLOCK 20
BLOCK 10
BLOCK 18
45° BEND w/TB
N: 19738.65
E: 10747.83
45° BEND w/TB
N: 19759.04
E: 10768.45
8"x6" SWIVEL TEE w/TB
1 - 6" G.V. (N)
1 - 8" G.V. (W)
N: 19765.39
E: 11360.97
FIRE HYDRANT
ASSEMBLY
N: 19782.39
E: 11361.07
REMOVE EXISTING CAP
CONNECT TO
EXISTING STUB
N: 19659.40
E: 10747.39
TRACT B 20' UTILITY, DRAINAGE,
ACCESS AND EMERGENCY ACCESS
HELLDIVER DRIVE (PRIVATE DRIVE)
PRIVATE DRIVE B
79.25 LF 8" PVC
N00°19'07"E
28.99 LF 8" PVC
N45°19'07"E
14.84 LF 8" PVC
S89°40'53"E
535.51 LF 8" PVC
S89°40'53"E
25.21 LF 8" PVC
N67°49'07"E
18.83 LF 8" PVC
S89°40'53"E
501.79 LF 8" PVC
S89°40'53"E
BARNSTORMER STREET
BIPLANE STREET
NAVION LANE
VINE DRIVE
VICOT WAY
YEAGER STREET
MARQUISE STREET
50' RAILROAD RIGHT OF WAY
BOOK 245, PAGE 76
& REC. NO. 99035876
BURLINGTON NORTHERN RAILROAD
6' UTILITY
EASEMENT
6' UTILITY
EASEMENT
PROPOSED UTILITY PLANS FOR:
EAST RIDGE SECOND FILING
DATED : 6.30.16
8"x6" SWIVEL TEE w/TB
1 - 6" G.V. (N)
1 - 8" G.V. (W)
N: 19758.96
E: 10783.29
FIRE HYDRANT
ASSEMBLY
N: 19775.95
E: 10783.38
LOT 1
LOT 2
LOT 3
LOT 4
LOT 5
LOT 6
LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12
LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18
LOT 19
LOT 20 LOT 21 LOT 22 LOT 23 LOT 24
LOT 25 LOT 26 LOT 27 LOT 28 LOT 29 LOT 30
LOT 31 LOT 32 LOT 33 LOT 34 LOT 35
LOT 36
LOT 61
LOT 62
LOT 63
LOT 64
LOT 65
LOT 66
LOT 67
LOT 68
LOT 69
LOT 70
LOT 71
LOT 72
LOT 73
LOT 74
LOT 75
LOT 76
LOT 77
LOT 78
LOT 82
LOT 83
LOT 84 LOT 85
LOT 86
LOT 87
LOT 88
LOT 89
LOT 90
LOT 91
LOT 92
LOT 93
LOT 94
LOT 95
LOT 96
TRACT A
BLOCK 1
TRACT B TRACT B
TRACT A
BLOCK 1
BLOCK 1
BLOCK 1
TRACT C TRACT D
TRACT M
22.5° BEND w/TB
N: 19765.50
E: 11342.14
22.5° BEND w/TB
N: 19755.98
E: 11318.79
STORM DRAIN A
SEE SHEET SD01
SANITARY LINE 1A
SEE SHEET SS01
SANITARY LINE 1
SEE SHEET SS01
STORM DRAIN A5
SEE SHEET SD08
STORM DRAIN A1
SEE SHEET SD02 STORM DRAIN B3
SEE SHEET SD04
SANITARY LINE 2.1
SEE SHEET SS03
STORM DRAIN A
SEE SHEET SD01
STORM DRAIN A1
SEE SHEET SD02
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_UT01-02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
PROPOSED RIGHT-OF-WAY
EXISTING WATER MAIN
PROPOSED 8" WATER MAIN
PROPOSED STORM SEWER
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
PROPOSED SEWER SERVICE S
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED WATER SERVICE/METER
PROPOSED FIRE HYDRANT
PROPOSED LOTLINE
EASEMENT LINE
PROPERTY BOUNDARY
PROPOSED ELECTRIC
W 8"
PROPOSED 8" SANITARY SEWER SS 8"
PROPOSED WATER LOWERING
PROPOSED MANHOLE
SS 8"
12" W
GAS
LEGEND:
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN
APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO
CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO
ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION.
2. WATER SERVICE PROVIDED BY EAST LARIMER COUNTY (ELCO) WATER DISTRICT. WATER CONSTRUCTION SHALL BE PER ELCO WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION.
3. SEWER SERVICE PROVIDED BY BOXELDER SANITATION DISTRICT. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION.
4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 4.5' AND MAXIMUM COVER SHALL BE 5.5' UNLESS OTHERWISE NOTED.
5. SANITARY SEWER SERVICES SHALL BE SDR-35 PVC AND WATER MAINS SHALL BE AWWA C-900 PVC.
6. ALL WATER FITTINGS AND VALVES ARE ARE NOT TO SCALE AND ARE ONLY GRAPHICALLY REPRESENTED.
7. UTILITY SERVICES SHOWN ARE SCHEMATIC ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
8. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
9. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
10. THE LIMITS OF STREET CUT ARE APPROXIMATE. FINAL STREET CUT LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE PER THE CITY STREET REPAIR
STANDARDS.
11. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
12. SEE SHEET EX02 & EX03 FOR EXISTING BOUNDARY CORNER COORDINATES.
13. ATTACHED SINGLE FAMILY DWELLINGS WILL REQUIRE A RESIDENTIAL SPRINKLER SYSTEM.
14. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN.
15. WATER SERVICE LINES WITH LESS THAN 1-FT OF CLEARANCE AT STORM DRAIN CROSSING AND WITH LESS THAN 4.5-FT OF COVER SHALL BE INSTALLED BELOW THE STORM DRAIN AND IN 1-1/2" (MIN.)
DIAMETER HDPE SLEEVE.
NOTES:
EXISTING WATER MAIN 8" W
MATCHLINE-SEE SHEET UT02
UT01 UT02
UT03
ROTATION: 0°
UT04
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4. CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5. CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6. 4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
7. REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
8. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
9. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
10. SOFT BOTTOM PAN AND ASSOCIATED UNDERDRAIN REQUIRED FOR SWALES LESS THAN 2% SLOPE.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND: NOTES:
LOT TEMPLATE A B
4550
50
GR01 GR02 GR03
GR05
GR06
GR04
GR07
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4. CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5. CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6. 4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
7. REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
8. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
9. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
10. SOFT BOTTOM PAN AND ASSOCIATED UNDERDRAIN REQUIRED FOR SWALES LESS THAN 2% SLOPE.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND: NOTES:
LOT TEMPLATE A B
4550
50
MATCHLINE SEE SHEET GR05
GR01 GR02 GR03
GR05
GR06
GR04
GR07
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4. CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5. CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6. 4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
7. REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
8. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
9. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
10. SOFT BOTTOM PAN AND ASSOCIATED UNDERDRAIN REQUIRED FOR SWALES LESS THAN 2% SLOPE.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND: NOTES:
LOT TEMPLATE A B
4550
50
MATCHLINE SEE SHEET GR06
MATCHLINE SEE SHEET GR04
GR01 GR02 GR03
GR05
GR06
GR04
GR07
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4. CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5. CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6. 4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
7. REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
8. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
9. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
10. SOFT BOTTOM PAN AND ASSOCIATED UNDERDRAIN REQUIRED FOR SWALES LESS THAN 2% SLOPE.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND: NOTES:
LOT TEMPLATE A B
4550
50
MATCHLINE SEE SHEET GR05
GR01 GR02 GR03
GR05
GR06
GR04
GR07
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
30Feet 0 30
30
60 90
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4. CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5. CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6. 4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
7. REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
8. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
9. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
10. SOFT BOTTOM PAN AND ASSOCIATED UNDERDRAIN REQUIRED FOR SWALES LESS THAN 2% SLOPE.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND: NOTES:
LOT TEMPLATE A B
4550
50
MATCHLINE-SEE SHEET GR02
GR01 GR02
GR04
GR05
GR06
GR03
GR07
TRACT E
LOT 112
LOT 49
LOT 45
2.7%
4.1%
4.5%
3.9%
2.5%
6.9%
5.2%
10.0%
3.2%
6.0%
6.3%
6.4%
3.5%
5.0%
1.4%
6.2%
4.2%
3.1%
5.3%
3.8%
6.5%
2.3%
3.9%
3.7%
10.3%
3.9%
2.5%
2.9
%
4.1%
7.3%
6.7%
3.7%
-4:1
-3:1
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_GR01-02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
30Feet 0 30
30
60 90
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4. CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5. CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6. 4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
7. REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
8. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
9. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
10. SOFT BOTTOM PAN AND ASSOCIATED UNDERDRAIN REQUIRED FOR SWALES LESS THAN 2% SLOPE.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND: NOTES:
LOT TEMPLATE A B
4550
50
MATCHLINE-SEE SHEET GR01
MATCHLINE-SEE SHEET GR03
GR01 GR03
GR04
GR05
GR06
GR02
GR07
LOT 75
5.0%
1.4%
6.2%
13.9%
2.8%
10.7%
14.6%
9.0%
20.1%
5.3%
10.3%
6.8%
1.9%
2.3%
3.7%
11.8%
4.9%
4.3%
9.9%
6
.0%
4.3%
3.5%
7.8%
4.2%
3.1%
5.3%
-3:1
-5:1
-6:1
2.1%
2.4%
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_GR01-02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP ROTATION: 0°
( IN FEET )
1 inch = ft.
30Feet 0 30
30
60 90
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2. REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3. ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4. CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5. CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6. 4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
7. REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
8. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
9. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
10. SOFT BOTTOM PAN AND ASSOCIATED UNDERDRAIN REQUIRED FOR SWALES LESS THAN 2% SLOPE.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND: NOTES:
LOT TEMPLATE A B
4550
50
MATCHLINE-SEE SHEET GR02
GR01 GR02 GR03
GR04
GR05
GR06
GR07
18''SS 18''SS
S
LOT 12
LOT 11
LOT 10
LOT 9
LOT 8
LOT 7
LOT6 5 LOT
LOT 4
LOT 1
LOT 3
LOT 2
LOT 15
LOT 14
LOT 13
LOT 12
LOT 11
LOT 2
LOT 3
LOT 4
LOT 5
LOT 6
LOT 7
LOT 1
LOT 8
LOT 9
LOT 10
LOT 1
LOT 2
LOT1 16 LOT
LOT 15
LOT14 3 LOT
LOT 4 LOT 13
LOT12 5 LOT
LOT 6 LOT 11
LOT10 7 LOT
LOT 7
LOT 6 LOT 13
LOT 5
LOT 14
LOT 4 LOT 15
LOT 3 LOT 16
LOT17 2 LOT
LOT 18
LOT 8 LOT 9
LOT 8 LOT 11
LOT 12
LOT 10
LOT 9
LOT 2 LOT 3 LOT 4
LOT 5 LOT 6
LOT12 13 LOT11 LOT10 LOT
LOT 1
LOT 14
LOT 7
LOT8 9 LOT
LOT 3 LOT 4 LOT 5
LOT11 12 LOT10 LOT
LOT 1 LOT 2
LOT13 14 LOT
LOT 6 LOT 7
LOT8 9 LOT
LOT 1
LOT 2
LOT 3 LOT 4
LOT 5
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
LOT 11
LOT 12
LOT 13
LOT 1
LOT 2
LOT 3
LOT 4
LOT 2 LOT 3 LOT 4
LOT 7 LOT 6 LOT 5
LOT 1 LOT 2
LOT 3 LOT 4
LOT 5
LOT28 29 LOT27 LOT
LOT30 31 LOT LOT 25
LOT 7 LOT 8 LOT 9
LOT23 24 LOT
LOT 6
LOT 26
LOT 10 LOT 11 LOT 12 LOT 13
LOT 1
LOT 8
LOT 14
LOT 19
LOT21 22 LOT20 LOT
LOT 18
LOT 17
LOT 16
LOT 15
LOT 2 LOT 3 LOT 4
LOT5 6 LOT
LOT 7
LOT 1 LOT 2 LOT 3
LOT 4 LOT 5 LOT 6 LOT 7
LOT18 19 LOT17 LOT16 LOT
LOT21 22 LOT20 LOT LOT 15
LOT 14 LOT 13
LOT9 8 LOT10 LOT
LOT 1
LOT 8
LOT 11
LOT 12
LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT8 9 LOT7 LOT
LOT10 11 LOT
LOT 12
LOT 3
LOT 2
LOT 4
LOT 5
LOT 1
LOT 3 LOT 14
LOT 4
LOT 5
LOT 13
LOT 12
LOT 1 LOT 16
LOT15 2 LOT
LOT 1
LOT 2
LOT 3
LOT 4
TRACT R
TRACT Q TRACT P
TRACT O
TRACT A
EAST RIDGE SECOND FILING
BLOCK 7
BLOCK 8
BLOCK 9
BLOCK 9
BLOCK 20
BLOCK 21
BLOCK 10
BLOCK 19
BLOCK 7
BLOCK 10
BLOCK 18
BLOCK 19
BLOCK 21
BLOCK 22
BLOCK 17 BLOCK 23
BLOCK 11
BLOCK 8
BLOCK 5
BLOCK 5
BLOCK 6
BLOCK 6
BLOCK 12
BLOCK 11
BLOCK 15
(UNPLATTED)
OWNER: WHITHAM FARMS LLC
REC. NO. 20010120159
BARNSTORMER STREET
BIPLANE STREET
NAVION LANE
VINE DRIVE
VICOT WAY
YEAGER STREET
MARQUISE STREET
BIPLANE STREET
BARNSTORMER STREET
VINE DRIVE
BURLINGTON NORTHERN RAILROAD
BURLINGTON NORTHERN RAILROAD
8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS
8''W
8''SS
8''W8''SS 8''W 8''W 8''SS 8''SS 8''SS 8''SS 8''SS
8''W 8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''SS 8''SS 8''SS 8''SS
PHASE
2A PHASE
2B
PHASE
2C
PHASE
3
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_PH02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
( IN FEET )
1 inch = ft.
100Feet 0 100
100
200 300
NOTES:
LEGEND:
PROJECT BOUNDARY
PHASE LINE
PHASING LEGEND:
PHASE ONE A -
PHASE ONE B -
PHASE ONE C-
PHASE TWO A -
PHASE TWO B -
PHASE TWO C-
PHASE THREE -
1. THE PHASE LINES SHOWN DELINEATE THE LOTS THAT ARE INCLUDED WITHIN A PHASE. GRADING AND
INSTALLATION OF INFRASTRUCTURE OUTSIDE THE LIMITS OF THE PHASE MAY BE REQUIRED.
2. ROADWAYS MAY REQUIRE SAWCUTS, MILLING AND/OR PATCHING OF ASPHALT. FINAL LIMITS WILL BE
DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL PATCHING AND STREET
REPAIRS SHALL BE PER THE MOST CURRENT CITY STANDARDS.
3. THE PHASING DESIGNATIONS SHOWN ARE FOR REFERENCE ONLY, THEY MAY NOT HAVE ANY
RELATIONSHIP TO THE ACTUAL CONSTRUCTION SEQUENCE.
4. TEMPORARY FIRE HYDRANTS ARE REQUIRED AT THE UPSTREAM END OF ALL "DEAD-END" WATER LINES
IN EACH PHASE. THE FIRE HYDRANTS SHALL BE REMOVED UPON CONTINUATION OF THE WATER MAIN
DURING THE CONSTRUCTION OF THE NEXT PHASE.
5. SANITARY SEWER MAIN SHALL BE EXTENDED TO THE NEXT MANHOLE BEYOND THE PHASE LINE.
6. FOR DETAILED OVERLOT GRADING SEE SHEETS GR01-GR06.
7. STORM MAY TERMINATE PRIOR TO THE MANHOLE NOTED WITHIN THE UTILITY PHASING TABLE. THE
TERMINATION SHALL OCCUR 20' BEYOND PHASING LINE OR 20' BEYOND THE EDGE OF PAVEMENT
WHICHEVER IS LONGER. IF THE STORM SYSTEM IS BROKEN BY PHASES, THE STORM SYSTEM MAY BE
COMPLETED OR A TEMPORARY SWALE MAY BE PROVIDED FROM INVERT TO INVERT WITH A MINIMUM 2'
FLAT BOTTOM AND A MAXIMUM 4:1 SIDE SLOPE.
8. CONTRACTOR SHALL ADEQUATELY MAINTAIN AND PROVIDE SNOW REMOVAL AS NEEDED DURING SITE
CONSTRUCTION.
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
ROTATION: 0°
TEMP. FIRE HYDRANT
PROPOSED
ROADWAY
END OF PHASE ROADWAY
AND UTILITY TERMINATIONS
TYPE III
BARRICADE
10'x5'x1.5' TYPE 'L'
RIPRAP PAD
10'x5'x1.5' TYPE 'L'
RIPRAP PAD
CONSTRUCT SANITARY TO
SS 8" NEXT MANHOLE
W 8" W 8"
SS 8"
PH01
UTILITY PHASING
PHASE REQUIRED UTILITY INFRASTRUCTURE
2A SANITARY SS LINE 1, SS LINE 1A
2A STORM SD LINE A, SD LINE A1, SD LINE A5
2B SANITARY SS LINE 2 (SSMH 2 - SSMH 2.2), SS LINE 2.1
2B STORM SD LINE B (INLET B TO INLET B4), SD LINE B3
2C SANITARY SS LINE 2 (SSMH 2.2 - SSMH 2.3)
2C STORM SD LINE B (INLET B4 TO INLET B7), SD LINE B5
3 SANITARY NONE
3 STORM SD LINE G, SD LINE H
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
ROTATION: 90°
NOTES:
LEGEND:
PROJECT BOUNDARY
PHASE LINE
PHASING LEGEND:
PHASE ONE A -
PHASE ONE B -
PHASE ONE C-
PHASE TWO A -
PHASE TWO B -
PHASE TWO C-
PHASE THREE -
1. THE PHASE LINES SHOWN DELINEATE THE LOTS THAT ARE INCLUDED WITHIN A PHASE. GRADING AND
INSTALLATION OF INFRASTRUCTURE OUTSIDE THE LIMITS OF THE PHASE MAY BE REQUIRED.
2. ROADWAYS MAY REQUIRE SAWCUTS, MILLING AND/OR PATCHING OF ASPHALT. FINAL LIMITS WILL BE
DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL PATCHING AND STREET
REPAIRS SHALL BE PER THE MOST CURRENT CITY STANDARDS.
3. THE PHASING DESIGNATIONS SHOWN ARE FOR REFERENCE ONLY, THEY MAY NOT HAVE ANY
RELATIONSHIP TO THE ACTUAL CONSTRUCTION SEQUENCE.
4. TEMPORARY FIRE HYDRANTS ARE REQUIRED AT THE UPSTREAM END OF ALL "DEAD-END" WATER LINES
IN EACH PHASE. THE FIRE HYDRANTS SHALL BE REMOVED UPON CONTINUATION OF THE WATER MAIN
DURING THE CONSTRUCTION OF THE NEXT PHASE.
5. SANITARY SEWER MAIN SHALL BE EXTENDED TO THE NEXT MANHOLE BEYOND THE PHASE LINE.
6. FOR DETAILED OVERLOT GRADING SEE SHEETS GR01-GR06.
7. STORM MAY TERMINATE PRIOR TO THE MANHOLE NOTED WITHIN THE UTILITY PHASING TABLE. THE
TERMINATION SHALL OCCUR 20' BEYOND PHASING LINE OR 20' BEYOND THE EDGE OF PAVEMENT
WHICHEVER IS LONGER. IF THE STORM SYSTEM IS BROKEN BY PHASES, THE STORM SYSTEM MAY BE
COMPLETED OR A TEMPORARY SWALE MAY BE PROVIDED FROM INVERT TO INVERT WITH A MINIMUM 2'
FLAT BOTTOM AND A MAXIMUM 4:1 SIDE SLOPE.
8. CONTRACTOR SHALL ADEQUATELY MAINTAIN AND PROVIDE SNOW REMOVAL AS NEEDED DURING SITE
CONSTRUCTION.
TEMP. FIRE HYDRANT
PROPOSED
ROADWAY
END OF PHASE ROADWAY
AND UTILITY TERMINATIONS
TYPE III
BARRICADE
10'x5'x1.5' TYPE 'L'
RIPRAP PAD
10'x5'x1.5' TYPE 'L'
RIPRAP PAD
CONSTRUCT SANITARY TO
SS 8" NEXT MANHOLE
W 8" W 8"
SS 8"
PH01
UTILITY PHASING
PHASE REQUIRED UTILITY INFRASTRUCTURE
1A SANITARY NONE
1A STORM SD LINE E, SD LINE F
1B SANITARY SS LINE 4, SS LINE 4.1, SS LINE 4.3
1B STORM SD LINE C, SD LINE C5, SD LINE C6, SD LINE C7
1C SANITARY SS LINE 3, SS LINE 3.1
1C STORM SD LINE D, SD LINE D1, SD LINE D3, SD LINE D8
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_EX03_S.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
LEGEND: NOTES:
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN
APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO
CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR
TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES THE SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT,
AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT ACCEPTS CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED
AGGREGATE (970) 482-1249.
4. ALL SYMBOLS ARE GRAPHICAL IN NATURE AND ARE NOT TO SCALE.
5. CONTACT THE ALTA SURVEYOR FOR INQUIRIES RELATED TO THE EXISTING SITE SURVEY.
6. CURB, GUTTER AND SIDEWALK SHALL BE REMOVED TO THE NEAREST JOINT.
7. CONTRACTOR SHALL COORDINATE THE REMOVAL AND/OR SALVAGING OF ALL EXISTING TREES WITH THE APPROVED LANDSCAPE PLANS. COORDINATE THE REMOVAL OF ALL OTHER PLANTINGS WITH
THE APPROVED LANDSCAPE PLANS.
8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT MAY OCCUR TO ANY ON-SITE, PUBLIC OR PRIVATE FACILITY AS A RESULT OF THE CONSTRUCTION PROCESS. THE CONTRACTOR
SHALL PROTECT TO THE EXTENT POSSIBLE ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO OR WITHIN THE CONSTRUCTION AREA.
10. THE LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEER INSPECTOR. ALL REPAIRS TO BE PER THE LATEST CITY STREET REPAIR
STANDARDS.
11. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS THAT IMPACT ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES.
12. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH EAST RIDGE SECOND FILING. CONTACT ENGINEER WITH ANY CONFLICTS.
EXISTING SANITARY SEWER
EXISTING WATER
PROPERTY BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
8"SS
8"W
EXISTING STORM
5015
5014
EXISTING STORM INLET
EXISTING MANHOLE
EXISTING SEWER SERVICE S
EXISTING CURB AND GUTTER
EX03
ROTATION: 90°
IN MONUMENT BOX
N=19948.88
E=12609.27
BIPLANE STREET
BARNSTORMER STREET
VINE DRIVE
50' RAILROAD RIGHT OF WAY
BOOK 245, PAGE 76
& REC. NO. 99035876
BURLINGTON NORTHERN RAILROAD
PROPOSED UTILITY PLANS FOR:
EAST RIDGE SECOND FILING
DATED : 6.30.16
EXISTING 8" WATER LINE
STUB FOR PROPOSED TOWNHOMES
CONNECTION
EXISTING 8" WATER LINE
STUB FOR PROPOSED TOWNHOMES
CONNECTION
TEMPORARY TURN AROUND PER
EAST RIDGE 2ND FILING
(TO BE REMOVED IF CONSTRUCTED)
6' UTILITY
EASEMENT
30' LANDSCAPE
SETBACK
PROPOSED SANITARY SEWER PER
EAST RIDGE SECOND FILING PLAN SET
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_EX01-EX02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
MATCHLINE-SEE SHEET EX01
LEGEND: NOTES:
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN
APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO
CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR
TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES THE SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT,
AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT ACCEPTS CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED
AGGREGATE (970) 482-1249.
4. ALL SYMBOLS ARE GRAPHICAL IN NATURE AND ARE NOT TO SCALE.
5. CONTACT THE ALTA SURVEYOR FOR INQUIRIES RELATED TO THE EXISTING SITE SURVEY.
6. CURB, GUTTER AND SIDEWALK SHALL BE REMOVED TO THE NEAREST JOINT.
7. CONTRACTOR SHALL COORDINATE THE REMOVAL AND/OR SALVAGING OF ALL EXISTING TREES WITH THE APPROVED LANDSCAPE PLANS. COORDINATE THE REMOVAL OF ALL OTHER PLANTINGS WITH
THE APPROVED LANDSCAPE PLANS.
8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT MAY OCCUR TO ANY ON-SITE, PUBLIC OR PRIVATE FACILITY AS A RESULT OF THE CONSTRUCTION PROCESS. THE CONTRACTOR
SHALL PROTECT TO THE EXTENT POSSIBLE ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO OR WITHIN THE CONSTRUCTION AREA.
10. THE LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEER INSPECTOR. ALL REPAIRS TO BE PER THE LATEST CITY STREET REPAIR
STANDARDS.
11. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS THAT IMPACT ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES.
12. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH EAST RIDGE SECOND FILING. CONTACT ENGINEER WITH ANY CONFLICTS.
EXISTING SANITARY SEWER
EXISTING WATER
PROPERTY BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
8"SS
8"W
EXISTING STORM
5015
5014
EXISTING STORM INLET
EXISTING MANHOLE
EXISTING SEWER SERVICE S
EXISTING CURB AND GUTTER
EX03
ROTATION: 0°
LOT 14
LOT 4 LOT 15
LOT 3 LOT 16
LOT 2 LOT 17
LOT 18
LOT 2 LOT 3 LOT 4
LOT 5 LOT 6
LOT 13 LOT 12 LOT 11 LOT 10
LOT 1
LOT 14
LOT 7
LOT 9 LOT 8
LOT 1 LOT 3 LOT 4 LOT 5
LOT 2 LOT 6 LOT 7
LOT 2 LOT 3 LOT 4
LOT 7 LOT 6 LOT 5
LOT 1
LOT 8
LOT 2 LOT 3 LOT 4
LOT 1
TRACT A
EAST RIDGE SECOND FILING
BLOCK 7
BLOCK 8
BLOCK 9
BLOCK 9
BLOCK 20
BLOCK 10
BLOCK 18
PROJECT BOUNDARY
EXISTING 30'
EMERGENCY ACCESS
EXISTING
10' UTILITY
EASEMENT
15' APPROXIMATE FUTURE
UTILITY EASEMENT
9' UTILITY AND
DRAINAGE
EASEMENT
EXISTING
20' DRAINAGE EASEMENT
TO BE VACATED BY
EAST RIDGE THIRD FILING PLAT
EXISTING FIRE
ACCESS GATE SHALL
NOT SWING INTO
PUBLIC R.O.W.
PROPOSED 30'
SANITARY SEWER
EASEMENT TO BE DEDICATED
EAST RIDGE THIRD FILING PLAT
PROPOSED UTILITY PLANS FOR:
EAST RIDGE SECOND FILING
DATED : 6.30.16
PROPOSED 36" STORM DRAIN PER
EAST RIDGE SECOND FILING UTILITY PLANS
BARNSTORMER STREET
BIPLANE STREET
NAVION LANE
VINE DRIVE
VICOT WAY
YEAGER STREET
MARQUISE STREET
50' RAILROAD RIGHT OF WAY
BOOK 245, PAGE 76
& REC. NO. 99035876
BURLINGTON NORTHERN RAILROAD
EXISTING 30'
SANITARY SEWER EASEMENT
TO BE VACATED BY
EAST RIDGE THIRD FILING PLAT
PROPOSED SANITARY SEWER PER
EAST RIDGE SECOND FILING PLAN SET
EXISTING 8" WATER LINE
STUB FOR PROPOSED TOWNHOMES
CONNECTION
6' UTILITY
EASEMENT
30' LANDSCAPE
SETBACK
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_EX01-EX02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
KEYMAP
( IN FEET )
1 inch = ft.
50Feet 0 50
50
100 150
MATCHLINE-SEE SHEET EX02
LEGEND: NOTES:
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN
APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO
CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR
TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES THE SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT,
AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT ACCEPTS CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED
AGGREGATE (970) 482-1249.
4. ALL SYMBOLS ARE GRAPHICAL IN NATURE AND ARE NOT TO SCALE.
5. CONTACT THE ALTA SURVEYOR FOR INQUIRIES RELATED TO THE EXISTING SITE SURVEY.
6. CURB, GUTTER AND SIDEWALK SHALL BE REMOVED TO THE NEAREST JOINT.
7. CONTRACTOR SHALL COORDINATE THE REMOVAL AND/OR SALVAGING OF ALL EXISTING TREES WITH THE APPROVED LANDSCAPE PLANS. COORDINATE THE REMOVAL OF ALL OTHER PLANTINGS WITH
THE APPROVED LANDSCAPE PLANS.
8. SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT MAY OCCUR TO ANY ON-SITE, PUBLIC OR PRIVATE FACILITY AS A RESULT OF THE CONSTRUCTION PROCESS. THE CONTRACTOR
SHALL PROTECT TO THE EXTENT POSSIBLE ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO OR WITHIN THE CONSTRUCTION AREA.
10. THE LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEER INSPECTOR. ALL REPAIRS TO BE PER THE LATEST CITY STREET REPAIR
STANDARDS.
11. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS THAT IMPACT ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES.
12. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH EAST RIDGE SECOND FILING. CONTACT ENGINEER WITH ANY CONFLICTS.
EXISTING SANITARY SEWER
EXISTING WATER
PROPERTY BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
8"SS
8"W
EXISTING STORM
5015
5014
EXISTING STORM INLET
EXISTING MANHOLE
EXISTING SEWER SERVICE S
EXISTING CURB AND GUTTER
EX03
ROTATION: 0°
service as well as the utility companies.
11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a
minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to
commencement of any work.
12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be
constructed prior to installation of the water lines and dry utilities.
13. The minimum cover over water lines is 4.5 feet and the maximum cover is 6.0 feet unless otherwise noted in the plans and approved by the Water Utility.
14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm
sewer, channel, irrigation ditch or any waters of the United States.
15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality
Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities
shall be the responsibility of the property owner(s).
17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved
by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of
occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release
of any building permits in excess of those allowed prior to certification per the Development Agreement.
18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from
groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain
its water, wastewater, and/or storm drainage facilities in the development.
19. All recommendations of the Preliminary Drainage and Erosion Control Reports for East Ridge Third Filing Montage Townhomes dated June 7, 2017 by Galloway and
Company, Inc., shall be followed and implemented.
20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair
by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within
24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street
inspector.
22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if
applicable.
23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify
the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days
prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper
notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not
to accept the improvement if subsequent testing reveals an improper installation.
24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to
the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report,
the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness
section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be
submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur
until the City of Fort Collins Engineer approves the final report.
25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections,
inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these
elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation
of base course or asphalt will be allowed on the streets.
26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these
standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce
the excavation necessary for building connections.
27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these
districts.
28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard
Area Mitigation Regulations in force at the time of final plat approval.
29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a
permit.
30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA
Publication 2226, Excavating and Trenching.
31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins,
Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any
and all traffic control devices as may be required by the construction activities.
32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations
Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be
charged for the labor, materials and equipment to reinstall the sign as needed.
33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street
operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development.
34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on
Sundays or holidays, unless there is prior written approval by Larimer County.
35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated
to be provided, installed, or constructed, unless specifically noted otherwise.
36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and
annotate the dimension on the as-built record drawings.
37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of
any permits and extension agreements needed for the job.
38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall
contact the Designer and the City of Fort Collins Engineer immediately.
39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's
Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer.
40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of
bearings. The information shall be as follows:
PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM)
BENCHMARKS: 92-3, TIMBERLINE RD. AT LARIMER-WELD IRRIGATION DITCH, ON THE SOUTH END OF THE EAST PARAPET WALL
ELEVATION: 4985.68
NOTE: IF NAVD88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + 3.19'
BENCHMARK: 41-01, ON THE NORTH SIDE OF EAST VINE DRIVE , WEST OF 3024 EAST VINE DRIVE, ON THE NORTH SIDE OF A ROUND ELECTRICAL
VAULT.
ELEVATION: 4966.54
NOTE: IF NAVD88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED + 3.18'
41. All stationing is based on centerline of roadways unless otherwise noted.
42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and
improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless
otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy.
43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be
documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street
Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets
where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay
shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made.
44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades
and condition as required by these plans.
45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a
minimum period of two years from the date of acceptance.
Approved Variances are listed as follows: Intersection spacing for Private Drive Helldiver Drive west side onto Barnstormer Street, and vacation of the temporary turnaround
on both the east end of Barnstormer Street and the south end of Zeppelin Way.
CONSTRUCTION NOTES
A. GRADING AND EROSION CONTROL NOTES
1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion
control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion
control report.
4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so
as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein.
5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for
immediate construction operations, and for the shortest practical period of time.
6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or
disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall
remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is
installed, unless otherwise approved by the City/County.
7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the
continued performance of their intended function.
b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector.
c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage
infrastructure and other public facilities.
9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make
sure streets and walkways are cleaned at the end of each working day.
10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into
any waters of the United States.
11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt
fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the
maintenance over to the City/County or Homeowners Association (HOA).
13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated
water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and
sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in
accordance with any and all applicable local, state, and federal regulations.
14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty
(50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed
of prior to the area being restored.
15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are
determined necessary, as directed by the City.
B. STREET IMPROVEMENT NOTES
1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here.
2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street
construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to
placement of any asphalt.
3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean
construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be
allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been
inspected and approved by the City of Fort Collins Engineer.
5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed.
6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be
documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished
patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay
work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work.
7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the
Right-of-Way Work Permit traffic control plan.
8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold
more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly.
9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is
proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base
material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires
inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits
excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth,
non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of
an Inspector.
C. TRAFFIC SIGNING AND PAVEMENT MARKING CONSTRUCTION NOTES
1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here.
2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5. All lane lines for concrete pavement should be epoxy paint.
6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their
placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols.
7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10. All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field
inspection must be corrected before the 2-year warranty period will begin.
12. The Developer installing signs shall be responsible for locating and protecting all underground utilities.
13. Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer
reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage
according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction
(except fair wear on traffic markings).
15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
D. STORM DRAINAGE NOTE
1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. The Developer shall be responsible for
maintenance of all storm drainage facilities that are constructed outside of the public right-of-way that are cited herein: The stormlines as noted on the plan and profiles
of this plan set.
2. All other storm drainage facilities designed with these utility plans are public and shall be maintained by the City of Fort Collins.
3. All recommendations of the Preliminary Drainage and Erosion Control Reports for East Ridge Third Filing Montage Townhomes dated June 7, 2017 by Galloway and
Company, shall be followed and implemented.
4. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved
by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of
occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release
of any building permits in excess of those allowed prior to certification per the Development Agreement.
5. 18" minimum vertical separation from other utilities is required including storm pipes and irrigation mains. Less than 18" will require a steel or concrete encasement of
the lower sewer or water.
E. EAST LARIMER COUNTY WATER DISTRICT STANDARD NOTES:
The following information is condensed from the current "Standard Construction Specifications for Water Mains" (Specification) as adopted by the East Larimer County Water District
('ELCO' or 'District') and is to be considered as such. In the event of any conflict the full District Specification document shall take precedence.
1. Standards and Specifications: Construction shall be per the East Larimer CountyWater District Standard Construction Specifications in effect at the start of construction.
2. Locates: It shall be the responsibility of the Contractor to coordinate field locates of all existing utilities prior to commencement of any construction. Contractor shall also notify
all
affected utility companies prior to commencing construction. In event of damage to any existing utility Contractor shall immediately notify owner of the utility involved and, unless
authorized in writing by the owner of the subject utility, shall not attempt to make repairs. Cost of repairs shall be the responsibility of the ContractorContractor.
3. Damage to Property: Contractor shall continuously maintain adequate protection from damage of all public and private property through which the work is done. done.
4. Safety: All water main installation within the ELCO Water District shall be subject to current OSHA and COSHA safety requirements. Contractor shall also comply with any and all
requirements and regulations as set forth by City, County, State and Federal agencies having applicable authority.
5. Landscaping Adjacent to District Waterlines: No landscaping (bushes, shrubs, trees or other plantings) that has a mature height of over 3 feet (3-ft) shall be placed within ten feet
(10-ft) of any District waterline (distribution main, service line, meter, etc.). The District shall have the right to remove any landscaping that violates this standard, at any time
such
landscaping is discovered, and shall not be required to replace the removed landscaping.
6. Design Approval and Notice of Construction Start: No construction shall begin without prior design approval from ELCO. District shall be notified 48 hours in advance of starting
construction or testing to allow for scheduling. District shall inspect the construction as necessary and shall observe all line testing. Construction or testing shall conform to District
Specifications at all times. In event that State or City road excavation permit(s) are required Contractor shall notify District of proposed construction schedule well in advance to
allow
time for District to obtain the required permit(s).
7. Permits: Contractor is responsible for obtaining all County road permits which may be required.
8. Changes During Construction: No verbal authorization for field revision shall be given. All requests for such field revision shall be made in writing accompanied by proposed change
indicated on copy of the approved design drawings. Any field revision approved and installed shall also be accurately documented on As-Built drawings as detailed below in these
Notes.
9. Materials of Construction:
a. Pipe - All water piping shall be Polyvinyl Chloride (PVC). All PVC piping through 12-inch shall be manufactured in accordance with AWWA Standard C900, "Polyvinyl Chloride
(PVC) Pressure Pipe, 4-inch through 12-inch, For Water Distribution", Class 150 (DR 18). All PVC piping 14-inch through 24-inch shall be manufactured in accordance with
AWWA Standard C905, "Polyvinyl Chloride (PVC) Water Transmission Pipe, Nominal Diameters 14-inch through 36", Class 200 (DR 18). Pipe with a diameter greater than 24
inches shall be specified based on engineered design. Pipe size shall be as shown on the approved plans. All water piping shall be installed with a twelve (12) gauge braided
copper wire, plastic coated, six hundred (600) volt taped to top of pipe and surfaced at each valve as a tracer wire. Pipe joints shall be made using an integral bell with an
elastomeric gasket push-on type joint or using machined couplings of a sleeve type with rubber ring gaskets and machined pipe ends to form a push-on type joint. All materials
installed shall be free of manufacturer defects. Any defective or damaged materials noted on the construction site shall be so marked and removed from the site. All fittings shall
be mechanical joint, ductile iron, manufactured in accordance with AWWA Standard C153. Fittings shall be furnished with a cement-mortar lining of standard thickness class with
a 250 psi pressure rating. Under no circumstances shall any PVC piping be installed utilizing mechanical equipment to seat the joints.
b.Gate Valves - Gate valves shall conform to AWWA Standard C509-87 with mechanical joint, 2" open left operating nut and resilient seat. Valve shall be Mueller A-2380-20 or
approved equal.
c.Butterfly Valves - Butterfly valves shall conform to AWWA Standard C504-80 with mechanical joint, 2" open left operating nut, resilient seat and shall be equipped with sand
bonnet. Valve shall be Mueller or approved equal.
d. Fire Hydrant Assembly - Hydrant shall conform to AWWA Standard C502-85, 1" square open right operating nut, no American Darling units. Mueller Super Centurion with epoxy
coated shoe or American Flo Control Waterous Pacer WB- 67-250X with epoxy coated shoe.
e. Fittings - All fittings shall be swing assemblies with anchor couplings.
10. Pipe Wrap: All fittings, valves, fire hydrant shoes and plugs shall be polywrapped with 8-mil thick polyethylene plastic wrap, double layered, and ends securely taped prior to backfill.
11. Bedding: All water main installation shall include bedding. Bedding shall be 3/4" washed rock uniformly graded and compacted. Trench shall be excavated to a depth below
established grade equal to 1/4 of pipe diameter (min. 4"). Bell depressions shall be provided for all joints. In event that unstable trench conditions are encountered at pipeline grade
1-1/2" uniformly graded washed rock shall be used for stabilization. Bedding material shall be placed and compacted under and around sides of the pipe. Place bedding in such a
manner as to provide solid, uniform bearing surface for full length of barrel. Minimum 30" backfill above pipe before other than hand compaction equipment is to be used. Note
maximum trench width detail.
12. Backfill: Backfilling of trench shall be performed as soon as practical, subsequent to inspection and approval. Backfilling of acceptable material shall be placed in lifts not greater
than
one (1) foot. Backfill shall be compacted to 95% of optimum density in roadway areas and 90% in all other locations. Compaction testing of bedding and backfill shall be at least five
tests per 1,000 feet and at varying depths and locations in accordance with the requirements of the applicable authority.
13. Thrust Blocks: All fittings, tees, plugs and fire hydrants shall be provided with anchor couplings and/or joint restraint in accordance with ELCO Specifications. Thrust blocks shall
be
used only as required per field conditions and as approved or directed by the ELCO field inspector.
14. Concrete: All concrete construction, including thrust blocks, shall be completed utilizing Type 5 or equal cement only.
15. Asphalt Replacement: In event that asphalt pavement is involved that has been in place less than two years (according to City or County Engineer's record) and is cut, the cut shall
be
a minimum of 20 feet in width and will be replaced to the specified depth by a paving machine.
16. Pipe Cover: A minimum cover of 4-1/2 feet shall be maintained throughout the waterline and service line installation, particularly in areas of new grading and drainage swales. Extra
bury depth may be required to maintain minimum cover at drainage culvert crossings and/or fire hydrant runs. Maximum allowable cover shall be 6 feet, unless specifically approved
by the District.
17. Connection to Existing System: All connections to existing waterlines shall be completed at developer's expense by ELCO personnel or the District's authorized contractor with no
exception.
18. Inspection: ELCO shall have the authority to ascertain that all construction of facilities is equal to or better than minimum construction requirements as set forth in the District’s
Specifications. The District shall also have the authority to assign an inspector to check any and all work, including all materials to be incorporated in the work, excavation, bedding,
backfill, testing and all construction methods and practices.
19. Testing and Acceptance: All lines shall be pressure tested, chlorinated and flushed by the Contractor in accordance with District Specifications and under the District's supervision.
Upon passing chlorination testing, bacteriological testing will be completed by an accredited water quality control laboratory. Copies of all passing test results, including soils
compaction in the area of water main construction, shall be provided to the District.
20. Project As-Built and Record Drawing Requirements:
a. As-built drawings are prepared by the contractor. They confirm, in red ink, on-site changes to the original construction documents. The As-built drawings shall be forwarded to
project’s design engineer for conversion to Record Drawings.
b. Record Drawings are prepared by the project’s design engineer and reflect onsite changes the contractor noted in the as-built drawings. The Record Drawings shall be approved by
ELCO prior to Preliminary Acceptance of the project. Record Drawings are to be delivered to the District in hard copy (11 x 17 format) and electronic format. Hard copy drawing text
font size shall be large enough to be legible with font size approved by the District. Electronic format shall be delivered in Adobe .pdf, AutoCAD and ArcView shape files (release
version to be confirmed with District at time of submittal). These documents shall accurately reflect any change made in the field which varies from the approved construction plan and
including, at a minimum, field dimensions and elevations, horizontal and vertical locations of underground utilities and appurtenances. Include with the Record Drawings a complete
copy of the recorded Filing Plat and a written confirmation of total costs of all water system improvements involved.
21. Warranty: The Contractor shall warrant all work associated with the waterline installation including, but not limited to the materials, installation workmanship and surface restoration
for a period of two years from date of Preliminary Acceptance. During this warranty period the Contractor shall repair any defects in the work and maintain the work area. At the close
of the two year warranty period and upon satisfactory correction of any deficiencies noted, the District shall accept the constructed lines and appurtenances as the sole property and
responsibility of the ELCO.
F. BOXELDER SANITATION DISTRICT CONSTRUCTION NOTES:
The following information is condensed from the current “Standard Construction Specification for Sewer Mains” as adopted by the Boxelder Sanitation District (District) and is to be
considered as such. In the event of any question the full document shall take precedence.
1. Existing Utility Locates: It shall be the responsibility of the Contractor to coordinate field locates of all existing utilities prior to commencement of any construction. Contractor
shall also
notify all affected utility companies prior to commencing construction. In the event of damage to any existing utility, the contractor shall immediately notify the owner of the utility
involved and unless authorized in writing by the owner of the subject utility, shall not attempt to make repairs. The cost of repairs shall be the responsibility of the Contractor.
2. District Owned Easement Pictures: Contractor to provide sequential digital pictures spaced at no more than 300 feet detailing conditions of the off-site Boxelder Owned Easement
Conditions and any structures that could be affected, to the District and the property owner prior to the start of any off-site work. These pictures shall include all existing fence,
ditches,
ditch structures, out buildings, water troughs, trees and all other landscaping. Pictures are to be placed at no more than four (4) pictures on a 11x8 sheet of photo paper inserted into
transparent sleeves and delivered with the drawings of record in a three (3) ring binder.
3. Protection of Property: Contractor shall continuously maintain adequate protection from damage of all public and private property through which the work is done.
4. Safety: All sewer main installation within the District shall be subject to current (Occupational Safety and Heath Association (OSHA) and the Colorado Safety Association, (CSA)
safety requirements. Contractor shall also comply with any and all requirements and regulations as set forth by City, County, State and Federal agencies having applicable authority.
5. Start of Construction: No construction shall begin without prior design review of the District. The District shall be notified 48 hours in advance of starting construction or testing
to allow
for scheduling.
6. Road Excavation Permits: In event that State, County or City road excavation permit(s) are required, the Contractor is responsible for obtaining all road permits which may be
required.
7. Other Permits: The Contractor shall be responsible for obtaining all permits required for construction.
8. Revisions: No verbal authorization for field revision shall be given. All requests for field revision shall be made in writing accompanied by proposed change indicated on copy of
the
approved design drawings. Any field revision approved and installed shall also be accurately documented on the Drawings of Record.
9. Materials: Plastic Pipe -All gravity sanitary sewer piping shall be Polyvinyl Chloride (PVC) unless otherwise noted on the approved drawings. Pipe 15” and smaller shall conform to
ASTM D3034, Type PSM, and SDR 35. Pipe 18” and larger shall conform to ASTM F679. All fittings shall be (PVC) unless otherwise noted.
10. Pipe Cover: A minimum cover of 3-1/2 feet of cover shall be maintained throughout the sewer line and service line installation.
11. Bedding: All sewer main installation shall include bedding. Bedding shall be ¾” washed rock uniformly graded and compacted. Refer to force main desgin for force main bedding
requirements. Trench shall be excavated to a depth below established grade equal to ¼ of pipe diameter (min. 4”). Bell depressions shall be provided for all joints. In event that
unstable trench conditions are encountered at pipeline grade 1-1/2” uniformly graded washed rock shall be used for stabilization. Bedding material shall be placed and compacted
under and around sides of the pipe. Place bedding in such a manner as to provide solid, uniform bearing surface for full length of barrel. Minimum 30” initial lift above pipe before
other than hand compaction equipment is to be used. Note maximum trench width detail.
12. Backfill: Backfilling of trench shall be performed as soon as practical, subsequent to inspection and approval. Backfilling of acceptable material shall not be placed in lifts of
greater
than one (1) foot. Backfill shall be compacted to 95% of optimum density in roadway and residential areas and 90% in all off-site easement areas unless otherwise noted. Compaction
testing of bedding and back fill shall be at least five tests per 1,000 feet and at varying depths and locations in accordance with the requirements of the applicable authority or as
required in project specific specifications.
13. Concrete: All concrete construction shall be completed utilizing 3,000 psi at twenty-eight (28) days or equal concrete.
14. Pavement or Other Repairs: In event that asphalt or concrete pavement, sidewalks, storm sewers, waterline or any other public or privately owned property is damaged or requires
reconstruction due to the work, repairs or replacement will be made in accordance with the requirements of the appropriate governing authority. Private property will be returned to its
original condition or as close to original condition as reasonably possible, unless otherwise noted on the drawings.
15. Service Taps on Existing Lines: All taps made on existing lines shall be completed at developer's expense by District personnel or the District's authorized contractor with no
exception.
16. Inspection: Construction shall conform to District Standards and Specifications or project specific specifications at all times. The District shall inspect the construction as necessary
and shall observe all line testing. The District shall have the authority to ascertain that all construction of facilities is equal to or better than minimum construction requirements
as set
forth in
17. Testing: All lines shall be pressure tested and flushed by the Contractor in accordance with District Standards and Specifications and under the District's supervision. Upon passing,
copies of all passing test results including soils compaction in the area of sewer main construction shall be provided to the District.
18. Acceptance: Upon completion of all utility construction (sewer and other) and fulfillment of all District requirements, preliminary acceptance of new sewer system improvements will
occur in accordance with District's acceptance procedure.
19. Warranty: The Contractor shall warrant the materials, installation, workmanship and surface restoration for a period of two years from date of preliminary acceptance. During this
warranty period the Developer shall promptly repair any defects in the work and maintain the work area. At the close of the two-year warranty period the District will make a field
inspection. Upon satisfactory correction of any deficiencies noted the District would make final acceptance of the lines and work. The lines and the appurtenances shall then become
the sole property and responsibility of Boxelder Sanitation District.
20. Drawings of Record and Total Costs: Within 90 days of preliminary acceptance of the new facilities, the District shall be provided with acceptable Drawings of Record of the complete
system consisting of two sets of fill size reproduced prints, two sets of ½-size reproduced prints, one set of 6 mil double matted reproducible mylars and one complete digital file
equivalent (software and version to be confirmed at time of delivery). Written confirmation of the total cost of all sewer system improvements shall also be submitted with the Drawings
of Record.
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_CV01-CV02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
3760 E. 15 Street, Suite 202
Loveland, Colorado 80538
970.800.3300
SITE ENGINEER / SURVEYOR
GAS Xcel Energy Stephanie Rich (970) 225-7828
ELECTRIC City of Fort Collins Light and Power Janet Mctague (970) 224-6152
CABLE Xfinity Don Kapperman (970) 484-7166
TELECOM. Centurylink William Johnson (970) 377-6401
WATER ELCO Mike Scheid (970) 493-2044
WASTEWATER Boxelder Sanitation District Karen Reynolds (970) 498-0604
STORMWATER City of Fort Collins Utilities Shane Boyle (970) 221-6700
UTILITY COMPANY CONTACT PHONE NUMBER
* ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN
APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
TYPICAL ROAD SECTIONS
S. TIMBERLINE RD.
E. VINE DRIVE
N. LEMAY AVE.
CityDate Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
GENERAL MANAGER
REVIEWED BY:
DATE:
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS
RESPONSIBLE FOR ACCURACY AND COMPLETENESS.
REVIEW DOES NOT CONSTITUTE "APPROVAL" OF PLANS. PLAN ENGINEER IS RESPONSIBLE
FOR ACCURACY AND COMPLETENESS.
GENERAL MANAGER
REVIEWED BY:
DATE:
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
PROJECT BENCHMARKS:
BENCHMARKS
PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT COLLINS DATUM)
BENCHMARKS: 92-3, TIMBERLINE RD. AT LARIMER-WELD IRRIGATION DITCH, ON THE SOUTH END OF THE EAST PARAPET WALL
ELEVATION: 4985.68
NOTE: IF NAVD88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29
UNADJUSTED + 3.19'
BENCHMARK: 41-01, ON THE NORTH SIDE OF EAST VINE DRIVE , WEST OF
3024 EAST VINE DRIVE, ON THE NORTH SIDE OF A
ROUND ELECTRICAL VAULT.
ELEVATION: 4966.54
NOTE: IF NAVD88 DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29
UNADJUSTED + 3.18'
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\3-CD\HFHLV1.02_Townhomes\HFHLV1.02_CV01-CV02_N.dwg - James Prelog - 6/7/2017
HFHLV0001.02
06.07.2017
# DateDescription Issue / Init.
EAST RIDGE THIRD FILING
MONTAGE TOWNHOMES
FORT COLLINS, CO
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL
BE ENFORCED AND PROSECUTED.
COPYRIGHT
PRELIMINARY
NOT FOR BIDDING
NOT FOR CONSTRUCTION
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
SITE
VICINITY MAP
SCALE: NTS
SITE
SITE
CV01 COVER SHEET
CV02 GENERAL AND CONSTRUCTION NOTES
EX01-EX03 EXISTING CONDITIONS
PH01-PH02 PHASING PLANS
GR01-GR07 GRADING PLANS
UT01-UT02 NORTH TOWNHOMES UTILITY PLANS
UT03 SOUTH TOWNHOMES UTILITY PLANS
UT04 POOL UTILITY PLANS
SS01-SS06 SANITARY SEWER PLAN AND PROFILE
SD01-SD09 STORM DRAIN PLAN AND PROFILE
RD01-RD02 PRIVATE DRIVE HELLDIVER DRIVE PLAN AND
PROFILE
RD03 PRIVATE DRIVE B & C PLAN AND PROFILE
RD04 PRIVATE DRIVE D PLAN AND PROFILE
RD05 PRIVATE DRIVE AA PLAN AND PROFILE
RD06 PRIVATE DRIVE THUNDERSTREAK LANE & CC
PLAN AND PROFILE
RD07 PRIVATE DRIVE VIGILANTE LANE PLAN AND
PROFILE
RD08 PRIVATE DRIVE EE & FF PLAN AND PROFILE
RD09-RD10 SIGNAGE PLAN
EC01-EC02 EROSION CONTROL PLAN
DR01-DR02 DRAINAGE PLANS
DT01-DT011 DETAILS
SHEET INDEX
EAST RIDGE THIRD FILING
CAUTION - NOTICE TO CONTRACTOR
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND
FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO
BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD
LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER
SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEERED PRIOR TO
CONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY
THE HORIZONTAL AND VERTICAL LOCATION OF SUCH
EXISTING UTILITY, EITHER THROUGH POTHOLING OR
ALTERNATIVE METHOD. REPORT INFORMATION TO THE
ENGINEER PRIOR TO CONSTRUCTION.
3. CONTRACTOR RESPONSIBLE FOR AS-BUILT DRAWINGS,
TESTS, REPORTS AND/OR ANY OTHER CERTIFICATES OR
INFORMATION AS REQUIRED FOR ACCEPTANCE OF WORK
FROM CITY, UTILITY DISTRICTS OR ANY OTHER GOVERNING
AGENCY.
4. CONTRACTOR SHALL PROTECT ALL EXISTING SURVEY