HomeMy WebLinkAbout2106 SOUTH TAFT HILL ROAD SINGLE FAMILY - PDP - PDP170002 - CORRESPONDENCE - RESPONSE TO STAFF REVIEW COMMENTS (2)Page 1 of 9
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com/developmentreview
March 24, 2017
Cara Scohy
CS Design
2519 S. Shields St #129
Fort Collins, CO 80524
RE: 2106 South Taft Hill Road Single Family, PDP170002, Round Number 2
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, you may contact the individual commenter or direct your questions through
the Project Planner, Meaghan Overton, at 970-416-2283 or moverton@fcgov.com.
Comment Summary:
Department: Engineering Development Review
Contact: Marc Ragasa, 970.221.6603, mragasa@fcgov.com
Topic: General
Comment Number: 6 Comment Originated: 02/14/2017
03/22/2017: Please call out the proposed sidewalk and show limits on the
plans, both on Taft and Dover Drive.
The proposed sidewalk limits along Taft and Dover Drive are now shown and spot elevations
have also been included on sheet C4.00.
02/14/2017: Per the Conceptual comments, a 6' detached walk is needed
south of the existing pedestrian ramp. This can be rebuilt with the new driveway
that is needed.
Comment Number: 8 Comment Originated: 02/14/2017
03/22/2017: The existing easement is between two private parties. This will
need to be dedicated to the City following the easement dedication process
detailed below.
An easement agreement has been submitted to the City.
02/14/2017: The existing sanitary sewer main will need to be in a Utility
Easement. The offsite drainage will also need to be in a Drainage Easement.
Please see the following link for the process for easement dedications:
http://www.fcgov.com/engineering/pdf/Easrowdedications2010.pdf . The fees
Page 2 of 9
are $250 per easement and the recording fees will vary depending on the
number of pages. A deed and legals will be required for each easement,
Please see the following link for the Easement Dedication Application:
http://www.fcgov.com/engineering/pdf/TDRF2012applicationform.pdf
Please see the following link for the Easement Dedication sample Deed:
http://www.fcgov.com/engineering/pdf/ESMwithAdminAcceptance9111.doc
Comment Number: 14 Comment Originated: 03/22/2017
03/22/2017: A utility easement dedication wasn't submitted with this round of
review. This easement dedication isn't required prior to hearing, only a letter of
intent.
An easement dedication has been submitted to the City.
Department: Environmental Planning
Contact: Stephanie Blochowiak, 970-416-4290, sblochowiak@fcgov.com
Topic: General
Comment Number: 5 Comment Originated: 03/22/2017
03/22/2017: Per discussion with Landscape Architect on 3/14/17, seed mix
examples include: Pawnee Buttes Seed Inc. (PBSI) Foothills Native Mix; PBSI
Native Prairie Mix; PBSI Native Sandyland Mix; Sharp Bros Seed Co Premium
Cover Sandy Soil Mix; Sharp Bros Seed Co Medium Grass Hardland Mix;
Sharp Bros Seed Co Medium Grass Sandy Soil Mix; additionally, custom mixes
can be ordered easily through Granite Seed and Erosion Control Company.
These are not endorsements of aforementioned companies, merely examples
of desired ecotypic seed mix use for our Foothills/Plains region. Acknowledged.
Topic: Landscape Plans
Comment Number: 2 Comment Originated: 02/13/2017
02/13/2017: Report seeding rate for seed mix in pounds per acre in addition to
pounds per square foot. Native Seed Mix pounds/acre drill seed application
rate should be at least 15 lbs/acre. If broadcast seed method is to be used
double the drill seed rate. Species selection looks better this round 2 of review
thank you. Per subsequent conversations and seed mix recommendations provided, the
detention mix (including grass seed and forbs) recommended by Environmental Planning has
been used as the Native Mix for this project.
Comment Number: 3 Comment Originated: 02/13/2017
02/13/2017: Add Seed Mix notes to landscape plans.
a. SEED SHALL BE PROVIDED BY (INSERT SEED MIX NAME AND
COMPANY FROM WHICH IT WILL COME FROM and COMPANY CONTACT
INFORMATION) AND THE GROUND SHALL BE CULTIVATED LIGHTLY
THEN SEEDED IN TWO DIRECTIONS TO DISTRIBUTE SEED EVENTLY
OVER ENTIRE AREA.
b. IF CHANGES ARE TO BE MADE TO SEED MIX BASED ON SITE
CONDITIONS APPROVAL MUST BE PROVIDED BY CITY ENVIRONMENTAL
Page 3 of 9
PLANNER.
c. PRIOR TO SEEDING SOIL WILL BE AERATED AND SOIL AMENDMENTS
ADDED AS NECESSARY. APPROPRIATE NATIVE SEEDING EQUIPMENT
WILL BE USED (STANDARD TURF SEEDING EQUIPMENT SHALL NOT BE
USED).
d. DRILL SEED APPLICATION RECOMMENDED PER SPECIFIED
APPLICATION RATE TO NO MORE THAN 1 INCH DEPTH. FOR
BROADCAST SEEDING INSTEAD OF DRILL SEEDING METHOD - DOUBLE
SPECIFICIED APPLICATION RATE. REFER TO NATIVE SEED MIX TABLE
FOR SPECIES, PERCENTAGES AND APPLICATION RATES.
e. TREAT SEED MIX AREA PRIOR TO INSTALLATION OF SEED WITH
APPROPRIATE HERBICIDE TO HELP CONTROL HERBACEOUS WEED
SPECIES. ONLY AFTER APPROPRIATE TIME PERIOD THEN APPLY SEED
AS CALLED FOR ON APPROVED PLANS.
f. AFTER SEEDING THE AREA SHALL BE COVERED WITH CRIMPED
STRAW OR OTHER APPROPRIATE METHODS AND PROVIDED
TEMPORARY IRRIGATION UNTIL SEED IS ESTABLISHED. CONTRACTOR
SHALL MONITOR SEEDED AREA FOR PROPER IRRIGATION, EROSION
CONTROL, GERMINATION AND RESEEDING AS NEEDED TO ESTABLISH
COVER.
g. THE APPROVED SEED MIX AREA IS INTENDED TO BE MAINTAINED IN
A NATURAL-LIKE LANDSCAPE AESTHETIC. IF AND WHEN MOWING
OCCURS IN NATIVE GRASS SEED MIX AREAS DO NOT MOW LOWER
THAN 6-8 INCHES IN HEIGHT TO AVOID INHIBITING NATIVE PLANT
GROWTH.
h. NATIVE SEED AREA WILL BE CONSIDERED ESTABLISHED WHEN
SEVENTY-PERCENT TOTAL COVER IS REACHED WITH NO LARGER
THAN ONE FOOT SQUARE BARE SPOTS AND/OR UNTIL DEEMED
ESTABLISHED BY CITY PLANNING SERVICES.
These notes have been added to sheet L4.
Department: Forestry
Contact: Molly Roche, , mroche@fcgov.com
Topic: Landscape Plans
Comment Number: 1 Comment Originated: 02/15/2017
3/24/2017:
Please add a note on the landscape plan in regards to the two unlabeled trees
on the north boundary line of the property. The note should read something to
the effect of: Trees X & Y are off-site and to remain. Forestry spoke with
Landscape Architect, Cara Scohy on March 24th to discuss this note. The line
weights for the trees as well as the text in the legend have been revised to more clearly
show which trees are on site and to remain/be removed as well as off site streets that
shall remain.
Page 4 of 9
3/22/2017:
Forestry will call the project’s Landscape Architect, Cara Scohy, to discuss how
trees from Taft Hill Rd are to be recorded on the plan.
- If all trees are off-site, they should be preserved and protected. If condition
warrants their removal, written approval from the adjacent property owner must
be received and reported to City Forestry. Noted. At this time only trees on this site and at 2107
Dover Drive will be removed due to improvements to the site and with the drainage and utility
easement at the 2107 Dover Dr. property (directly east of this site and noted on plans).
02/15/2017:
Existing Trees
The proposed drainage swale on the North side of the property appears to be
quite close to some significant trees that are to be retained. To further evaluate,
Forestry requests that the applicant schedule a meeting with the City Forester to
review impact to tree roots. This will be scheduled.
The three smaller Ash, along the northern boundary and closest to Taft Hill Road
are not numbered nor included in the tree mitigation table. Please include these
trees on the plans. The tree closest to Taft has been added to the plans (#13); per additional
photos sent via email on 4/12/17, the other trees are on the property to the north. The line
weights for the trees as well as the text in the legend have been revised to more clearly
show which trees are on site and to remain/be removed as well as off site streets that
shall remain.
Tree #1 has a major trunk cavity and is potentially hazardous. City Forestry
recommends that this tree be removed for safety concerns. This tree is now marked for removal
and this note has been added to the table on sheet L1.
If any off-site boundary trees will be removed by this project, then written
approval by the adjacent property owner should be provided and submitted to
the City Forester. Noted. 2107 Dover Drive where the trees marked for removal (due to
our site improvements and in the drainage and utility easement) is under the same ownership as
this property under review and they are aware of the trees removal status.
Department: Historic Preservation
Contact: Maren Bzdek, 970-221-6206, mbzdek@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/15/2017
02/15/2017: The existing residence and associated garage at 2106 S. Taft Hill
Road were evaluated on January 20, 2017 to determine if the structures are
eligible for designation as local Fort Collins landmarks. The Director of CDNS
and a member of the Landmark Preservation Commission performed that
evaluation, which determined that both structures are fine examples of
streamline moderne architecture and are eligible for designation. The
determination was posted for 14 days to allow for appeal and no action was
taken during that period. That determination requires the subsequent
development on and near the parcel to be evaluated under Land Use Code
Page 5 of 9
section 3.4.7. Understood. A note has been added to the plat for Lot 2 of this development
Comment Number: 2 Comment Originated: 02/15/2017
02/15/2017: LUC 3.4.7 ensures that, to the maximum extent feasible, historic
sites and structures are preserved and incorporated into proposed
development and undertakings that may alter the characteristics of a historic
property must avoid adversely affecting the integrity of the property and respect
its character. Historic Preservation staff has met with the applicant and
discussed the particular importance of applying 3.4.7 to new construction on Lot
2 of the proposed development. Its abutting proximity to the historic buildings
will require a building design that meets the requirements of 3.4.7 regarding
height, setback, width, compatible design elements and building materials,
historic landscaping, and visual and pedestrian connections. The parties
agreed that a note would be added to the plat as well as the development
agreement that includes the following language: "As required by Land Use
Code section 3.4.7(F), the new construction on Lot 2 shall be similar to the
height, setback, and width of existing historic structures to the maximum extent
feasible, and shall be designed to be in character with same based on visual
elements such as window patterns and use of brick as the dominant building
material. In order to receive a building permit for Lot 2, a review for compliance
with 3.4.7 will be required and must also include a plan of protection for the
existing historic structures that specifies how they will be protected from
damage during construction." Understood. A note has been added to the plat for Lot 2 of this
development.
Department: Light And Power
Contact: Todd Vedder, 970-224-6152, tvedder@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/15/2017
There is currently single phase and three phase power available to the north
along Taft Hill Rd. Noted.
Comment Number: 2 Comment Originated: 02/15/2017
Streetlights will need to be placed along public streets. A 40 feet separation on
both sides of the light is required between shaded trees and streetlights. A 15
feet separation on both sides of the light is required between ornamental trees
and streetlights. This is a private drive and street lights will not be placed.
Comment Number: 3 Comment Originated: 02/15/2017
New development and system modification charges may apply. A link to our
online electric fee estimator is below.
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investmen
t-development-fees/electric-development-fee-estimator?id=3 Noted.
Comment Number: 4 Comment Originated: 02/15/2017
Please contact Light & Power if you have any questions. Please reference our
Electric Service Standards to ensure requirements are met. A copy of this link
Page 6 of 9
is below.
http://www.fcgov.com/utilities/business/builders-and-developers/development-fo
rms-guidelines-regulations
Noted.
Comment Number: 5 Comment Originated: 02/15/2017
Please provide the breaker panel size for each dwelling unit. Also inform if units
will be gas or electric heat. This will be determined at the time of permit.
Comment Number: 6 Comment Originated: 02/15/2017
Please reference our Electric Service Standards and coordinate transformer
locations with Light & Power. This will be determined at the time of permit.
Comment Number: 7 Comment Originated: 02/15/2017
Please contact Todd Vedder with Light & Power Engineering Department if you
have any questions at 970.224.6152 or tvedder@fcgov.com Noted.
Department: PFA
Contact: Cal Sheesley, 970-416-2599, csheesley@poudre-fire.org
Topic: General
Comment Number: 3 Comment Originated: 02/02/2017
02/02/2017: FIRE LANE SIGNS
The limits of the fire lane shall be fully defined throughout. Fire lane sign
locations should be indicated on future plan sets. Refer to LUCASS detail
#1418 for sign type. Appropriate directional arrows required on all signs. Code
language provided below.
> IFC D103.6: Where required by the fire code official, fire apparatus access
roads shall be marked with permanent NO PARKING - FIRE LANE signs
complying with Figure D103.6. Signs shall have a minimum dimension of 12
inches wide by 18 inches high and have red letters on a white reflective
background. Signs shall be posted on one or both sides of the fire apparatus
road as required by Section D103.6.1 or D103.6.2.
Signage meets the requirement on the Emergency Access Exhibit (S2) but
does not appear to have been changed on the Private Drive Street Plan and
Profile (Sheet C4.01). Please revise C4.01 to reflect the required signage as
shown on sheet S2. Specifically, along the south side of the EAE, 4 signs need
to be shown, there is not a sign at the west end of the EAE.
All the required signs and correct language have now been labeled on sheet
C4.00 and C4.01
Comment Number: 8 Comment Originated: 03/17/2017
03/17/2017: EMERGENCY ACCESS EASEMENT
The Emergency Access Easement (EAE) extends to the east end of the
cul-de-sac on the Site Plan and the Emergency Access Exhibit (S1 & S2) but
the revised plat (sheet 2) does not match S1 & S2. For consistency, please
Page 7 of 9
revise the plat to show the EAE extending the the east end of the cul-de-sac as
it does in S1 & S2. The plat has been updated to match sheet S1 and S2.
Comment Number: 9 Comment Originated: 03/22/2017
03/22/2017: FIRE LANE TURNAROUND
The surface of the hammerhead turnaround will need to be identified and
labeled on future plans prior to FDP approval. Concrete, asphalt, pavers, etc.
are considered acceptable as a hard surface.
> Any other plan or product will require review and approval by the fire marshal.
> The turnaround shall be engineered to support 40 tons.
> The condition of the turnaround will need to be maintained in perpetuity and
kept clear of snow or other obstructions as needed. Language to this effect
should be included in the HOA language.
The surface will be paved with an all weather surface.
Department: Planning Services
Contact: Meaghan Overton, 970-416-2283, moverton@fcgov.com
Topic: General
Comment Number: 3 Comment Originated: 02/14/2017
03/20/2017: Applicant is discussing plat and development agreement
language with Historic Preservation.
02/14/2017: The existing home on the site is greater than 50 years in age, and
will need to be evaluated through the historic preservation demolition/alteration
review process. In addition, notes will need to be added to the Development
Agreement and the Plat regarding the review process for development on Lot 2.
Please see comments from historic preservation. Understood. A note has been added to the
plat for Lot 2 of this development.
Department: Stormwater Engineering
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
Topic: Erosion Control
Comment Number: 1 Comment Originated: 02/06/2017
03/21/2017: Current Erosion Control Materials Submitted do not meet
requirements. Please submit; an Erosion Control Plan (was acceptable), an
Erosion Control Report (not included in submitted material), and an Escrow /
Security Calculation (not included in submitted material). Also, based upon the
area of disturbance State permits for stormwater will be required since the site
is over an acre. If you need clarification concerning the erosion control section,
or if there are any questions please contact Jesse Schlam 970-218-2932 or
email @ jschlam@fcgov.com
SWMP and Escrow have been included with this submittal.
02/06/2017: The site disturbs more than 10,000 sq. ft., therefore Erosion and
Sediment Control Materials need to be submitted for FDP. The erosion control
requirements are in the Stormwater Design Criteria under the Amendments of
Page 8 of 9
Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials
Submitted do not meet requirements. Please submit; an Erosion Control Plan
(based upon redlines returned), an Erosion Control Report (not included in
submitted material), and an Escrow / Security Calculation (not included in
submitted material). Also, based upon the area of disturbance State permits for
stormwater will be required since the site is over an acre. If you need
clarification concerning the erosion control section, or if there are any questions
please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com
Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com
Topic: General
Comment Number: 2 Comment Originated: 02/14/2017
03/22/2017: Since the LID swale is not needed to reach the 50% LID
requirement, this swale can be just a grass lined swale.
02/14/2017: The LID swale along the north property line needs to be designed
with the full media section and underdrain. Also, a drywell will need to be
included due to not having an outfall for the underdrain into the detention basin.
The bio-swale has been removed from the plans and the pavers treat 57 percent of the overall
impervious area on site.
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Construction Drawings
Comment Number: 11 Comment Originated: 02/17/2017
03/24/2017: There are line over text issues. See redlines.
02/17/2017: There are line over text issues. See redlines.
Line over text issues have been fixed.
Topic: Plat
Comment Number: 1 Comment Originated: 02/17/2017
03/24/2017: Please make changes as marked. If changes are not made or you
disagree with comments, please provide written response of why corrections
were not made. Please provide any responses on redlined sheets and/or in
response letter.
02/17/2017: Please make changes as marked. If changes are not made or you
disagree with comments, please provide written response of why corrections
were not made. Please provide any responses on redlined sheets and/or in
response letter.
Topic: Site Plan
Comment Number: 14 Comment Originated: 03/24/2017
03/24/2017: Some of the sheet titles in the sheet index do not match the sheet
titles on the noted sheets. See redlines. This has been revised.
Department: Water Conservation
Contact: Eric Olson, 970-221-6704, eolson@fcgov.com
Topic: General
Page 9 of 9
Comment Number: 1 Comment Originated: 02/16/2017
02/16/2017: Irrigation plans are required no later than at the time of building
permit. The irrigation plans must comply with the provisions outlined in Section
3.2.1(J) of the Land Use Code. Direct questions concerning irrigation
requirements to Eric Olson, at 221-6704 or eolson@fcgov.com
Noted.
Department: Water-Wastewater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com
Topic: General
Comment Number: 2 Comment Originated: 02/17/2017
03/22/2017: The water main is still labeled as 8 inches.
Water main is now labeled as “6-inch Water Line.”
02/17/2017: The water main can be 6-inches in diameter due to the minimal
lots for water quality reasons.
Comment Number: 3 Comment Originated: 02/17/2017
03/22/2017: The sanitary sewer main is now in conflict with proposed trees
within the detention basin.
Proposed trees have been shifted to avoid conflict.
02/17/2017: The west sanitary sewer manhole needs to be relocated out of the
curb & gutter.
Department: Zoning
Contact: Marcus Glasgow, 970-416-2338, mglasgow@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 02/13/2017
02/13/2017: Please add summary to site plan with typical building setbacks. A setback summary
has been added to sheet S1.
3/21/2017: Typical setbacks ok for front and sides but rear is showing a zero
setback. Rear must be 15 ft. This has been corrected; 15' rear setbacks are now shown.