HomeMy WebLinkAboutLEGACY AUTO - FDP - FDP170014 - SUBMITTAL DOCUMENTS - ROUND 1 - ARCHITECTURAL DETAILS419 Canyon Avenue, Suite 200 Fort Collins, CO 80521
ph: 970.224.1191 www.VFLA.com
DRAWING NUMBER:
PROJECT NUMBER:
SEAL:
IN ASSOCIATION WITH:
Strength in design. Strength in partnership.
Strength in community.
VAUGHT FRYE LARSON ARCHITECTS, INC.
THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR
COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF
VFLA.
CHECKED BY:
DRAWN BY:
COPYRIGHT:
Issued
No. Description Date
1 05-17-17
Revisions
2
3
4
5
6
No. Description Date
VAUGHT FRYE LARSON architects
FINAL DEVELOPMENT PLANS
5/16/2017 4:06:00 PM
5/16/2017 4:06:00 PM
G:\2017\17-26 Legacy Auto\4 Revit\LEGACY AUTO_CENTRAL v17.rvt
FDP-C5.1
DEVELOPMENT PLANS
- ARCHITECTURAL
DETAILS
LEGACY AUTO
1845 NORTH COLLEGE
FORT COLLINS, CO 80524
FINAL DEVELOPMENT PLANS
2017-26
AG
AG
FIN. FLOOR
100' - 0"
T.O. LOW ROOF
110' - 2 1/2"
12' - 11 1/2" ± 1' - 4"
8' - 10 1/2" 1' - 4" 3' - 10 1/2"
14' - 0 1/2" ±
REMOVE EXISTING AREA
LIGHTING ON CANOPY
REMOVE EXISTING AREA
LIGHTING ON CANOPY
EXISTING CANOPY SUPPORT
BEAMS TO REMAIN
EXISTING CANOPY & FASCIA
TO REMAIN
REMOVE EXISTING AREA
LIGHTING ON BUILDING
REMOVE EXISTING AREA
LIGHTING ON BUILDING
EXISTING WOOD
SIDING TO REMAIN
EXISTING METAL TRIM
AND GUTTER TO REMAIN
REMOVE EAVE ON
NORTH SIDE OF
BUILDING
EXISTING STONE
VENEER TO REMAIN
EXISTING WOOD
SIDING TO REMAIN
EXISTING LEAN-TO
TO REMAIN
REMOVE EXISTING
DOOR AND FRAME
REMOVE EXISTING
CONCRETE WALKS
EXISTING CANOPY
COLUMNS TO REMAIN
REMOVE EXISTING
CANOPY ISLANDS
FIN. FLOOR
100' - 0"
T.O. LOW ROOF
110' - 2 1/2"
REMOVE EXISTING AREA
LIGHTING ON CANOPY
REMOVE EXISTING AREA
LIGHTING ON CANOPY
EXISTING CANOPY SUPPORT
BEAMS TO REMAIN
EXISTING CANOPY &
FASCIA TO REMAIN
EXISTING WOOD
SIDING TO REMAIN
EXISTING METAL TRIM
AND GUTTER TO REMAIN
EXISTING CANOPY
COLUMNS TO REMAIN
REMOVE EXISTING
CANOPY ISLANDS
FIN. FLOOR
100' - 0"
T.O. PARAPET WALL
130' - 0"
T.O. LOW ROOF
110' - 2 1/2"
EXISTING NEW
NEW HORIZONTAL
S-DECK METAL
PANEL
GROUND FACE CMU.
COLOR TO MATCH
STONE VENEER ON
EXISTING BUILDING
DARK BRONZE
ALUMINUM
STOREFRONT
SYSTEM
DARK BRONZE
ALUMINUM
STOREFRONT
SYSTEM
GROUND FACE CMU.
COLOR TO MATCH
STONE VENEER ON
EXISTING BUILDING
DARK BRONZE
ALUMINUM
STOREFRONT
SYSTEM
DARK BRONZE
ALUMINUM
STOREFRONT
SYSTEM
GROUND FACE CMU.
COLOR TO MATCH
STONE VENEER ON
EXISTING BUILDING
DARK BRONZE
ALUMINUM
STOREFRONT
SYSTEM
DARK BRONZE
CONCEALED FASTENER
HORIZONTAL METAL
PANEL
DARK BRONZE
CONCEALED FASTENER
HORIZONTAL METAL
PANEL
PROPOSED SIGN LOCATION.
SIGN TO BE SUBMITTED
UNDER SEPARATE PERMIT
PROPOSED SIGN LOCATION.
SIGN TO BE SUBMITTED
UNDER SEPARATE PERMIT
PROPOSED SIGN
LOCATION. SIGN TO BE
SUBMITTED UNDER
SEPARATE PERMIT
FIN. FLOOR
100' - 0"
T.O. PARAPET WALL
130' - 0"
T.O. LOW ROOF
110' - 2 1/2"
VERTICAL
ARCHITECTURAL
METAL PANEL
HOLLOW METAL
DOOR.
NEW HORIZONTAL
S-DECK METAL
PANEL
DARK BRONZE
ALUMINUM FRAMED
OVERHEAD DOOR
VERTICAL
ARCHITECTURAL
METAL PANEL
DARK BRONZE
ALUMINUM FRAMED
OVERHEAD DOOR
METAL ROOF
FIN. FLOOR
100' - 0"
T.O. PARAPET WALL
130' - 0"
T.O. LOW ROOF
110' - 2 1/2"
PROPOSED SIGN
LOCATION. SIGN TO BE
SUBMITTED UNDER
SEPARATE PERMIT
HORIZONTAL S-DECK
METAL PANEL
VERTICAL
ARCHITECTURAL
METAL PANEL
STANDING SEAM METAL
ROOF OVER LIGHT GAUGE
FRAMING WITH FASCIA
COLOR TO MATCH EXISTING
GROUND FACE CMU. COLOR TO MATCH
STONE VENEER ON EXISTING BUILDING
419 Canyon Avenue, Suite 200 Fort Collins, CO 80521
ph: 970.224.1191 www.VFLA.com
DRAWING NUMBER:
PROJECT NUMBER:
SEAL:
IN ASSOCIATION WITH:
Strength in design. Strength in partnership.
Strength in community.
VAUGHT FRYE LARSON ARCHITECTS, INC.
THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR
COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF
VFLA.
CHECKED BY:
DRAWN BY:
COPYRIGHT:
Issued
No. Description Date
1 05-17-17
Revisions
2
3
4
5
6
No. Description Date
VAUGHT FRYE LARSON architects
FINAL DEVELOPMENT PLANS
5/16/2017 4:10:05 PM
5/16/2017 4:10:05 PM
G:\2017\17-26 Legacy Auto\4 Revit\LEGACY AUTO_CENTRAL v17.rvt
FDP-A4.3
DEVELOPMENT PLANS
- EXTERIOR
ELEVATIONS
LEGACY AUTO
1845 NORTH COLLEGE
FORT COLLINS, CO 80524
FINAL DEVELOPMENT PLANS
2017-26
AG
JL
1 1/8" = 1'-0"
WEST ELEVATION
PERSPECTIVE - NORTHWEST
2 1/8" = 1'-0"
NORTH ELEVATION
HORIZONTAL S-DECK
METAL PANEL
VERTICAL
ARCHITECTURAL
METAL PANEL
HORIZONTAL S-DECK
METAL PANEL
VERTICAL
ARCHITECTURAL
METAL PANEL
HORIZONTAL S-DECK
METAL PANEL
AWNING WITH
METAL FASCIA TO
MATCH EXISTING
STANDING SEAM METAL
ROOF OVER LIGHT GAUGE
METAL FRAMING WITH METAL
FASCIA TO MATCH EXISTING
STEEL POST
STRUCTURE TO
SUPPORT AWNING.
PAINT DARK BRONZE
STEEL POST
STRUCTURE TO
SUPPORT AWNING.
PAINT DARK
BRONZE
FIN. FLOOR
100' - 0"
T.O. PARAPET WALL
130' - 0"
T.O. LOW ROOF
110' - 2 1/2"
NEW HORIZONTAL S-DECK
METAL PANEL
PROPOSED SIGN
LOCATION. SIGN
TO BE SUBMITTED
UNDER
SEPARATE
PERMIT
HORIZONTAL S-DECK
METAL PANEL
VERTICAL
ARCHITECTURAL
METAL PANEL
DARK BRONZE
ALUMINUM FRAMED
OVERHEAD DOOR
STANDING SEAM
METAL ROOF
OVER LIGHT
GAUGE FRAMING
WITH FASCIA
COLOR TO MATCH
EXISTING
GROUND FACE CMU. COLOR
TO MATCH STONE VENEER
ON EXISTING BUILDING
419 Canyon Avenue, Suite 200 Fort Collins, CO 80521
ph: 970.224.1191 www.VFLA.com
DRAWING NUMBER:
PROJECT NUMBER:
SEAL:
IN ASSOCIATION WITH:
Strength in design. Strength in partnership.
Strength in community.
VAUGHT FRYE LARSON ARCHITECTS, INC.
THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR
COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF
VFLA.
CHECKED BY:
DRAWN BY:
COPYRIGHT:
Issued
No. Description Date
1 05-17-17
Revisions
2
3
4
5
6
No. Description Date
VAUGHT FRYE LARSON architects
FINAL DEVELOPMENT PLANS
5/16/2017 4:28:52 PM
5/16/2017 4:28:52 PM
G:\2017\17-26 Legacy Auto\4 Revit\LEGACY AUTO_CENTRAL v17.rvt
FDP-A4.2
DEVELOPMENT PLANS
- EXTERIOR
ELEVATIONS
LEGACY AUTO
1845 NORTH COLLEGE
FORT COLLINS, CO 80524
FINAL DEVELOPMENT PLANS
2017-26
AG
JL
PERSPECTIVE - NORTHEAST
1 1/8" = 1'-0"
EAST ELEVATION
2 1/8" = 1'-0"
SOUTH ELEVATION
EXISTING EAVE AND
FASCIA TO REMAIN
EXISTING WINDOW
TO REMAIN
REMOVE EXISTING WOOD SIDING AND REPLACE
WITH HORIZONTAL S-DECK METAL SIDING
EXISTING LEAN-TO
TO REMAIN
REMOVE EXISTING
CONCRETE WALKS
EXISTING WOOD
DOORS TO REMAIN
REMOVE EXISTING WOOD
SIDING AND REPLACE
WITH HORIZONTAL S-DECK
METAL SIDING
FIN. FLOOR
100' - 0"
T.O. LOW ROOF
110' - 2 1/2"
EXISTING EAVE AND
FASCIA TO REMAIN
REMOVE EXISTING WOOD SIDING AND REPLACE
WITH HORIZONTAL S-DECK METAL SIDING
REMOVE EXISTING CONCRETE WALKS
EXISTING LEAN-TO
TO REMAIN
REMOVE EXISTING AREA
LIGHTING ON CANOPY
REMOVE EXISTING
AREA LIGHTING
ON BUILDING
REMOVE EAVE
ON NORTH SIDE
OF BUILDING
EXISTING METAL TRIM
AND GUTTERS TO
REMAIN
EXISTING CANOPY BEAMS
AND COLUMNS TO REMAIN
EXISTING CANOPY &
FASCIA TO REMAIN
FIN. FLOOR
100' - 0"
T.O. LOW ROOF
110' - 2 1/2"
EXISTING EAVE AND
FASCIA TO REMAIN
REMOVE EXISTING WOOD SIDING AND REPLACE
WITH HORIZONTAL S-DECK METAL SIDING
REMOVE EXISTING
CONCRETE WALKS
REMOVE EXISTING AREA
LIGHTING ON CANOPY
REMOVE EAVE ON
NORTH SIDE OF BUILDING
REMOVE EXISTING AREA
LIGHTING ON BUILDING
EXISTING CANOPY BEAMS
AND COLUMNS TO REMAIN
EXISTING CANOPY &
FASCIA TO REMAIN
EXISTING WINDOW
TO REMAIN
REMOVE EXISTING
CANOPY ISLANDS
EXISTING CANOPY
COLUMNS TO REMAIN
EXISTING WINDOWS
TO REMAIN
REMOVE EXISTING WOOD SIDING AND REPLACE
WITH HORIZONTAL S-DECK METAL SIDING
EXISTING STONE
VENEER TO REMAIN
REMOVE AND REPLACE
OVERHEAD DOOR
419 Canyon Avenue, Suite 200 Fort Collins, CO 80521
ph: 970.224.1191 www.VFLA.com
DRAWING NUMBER:
PROJECT NUMBER:
SEAL:
IN ASSOCIATION WITH:
Strength in design. Strength in partnership.
Strength in community.
VAUGHT FRYE LARSON ARCHITECTS, INC.
THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR
COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF
VFLA.
CHECKED BY:
DRAWN BY:
COPYRIGHT:
Issued
No. Description Date
1 05-17-17
Revisions
2
3
4
5
6
No. Description Date
VAUGHT FRYE LARSON architects
FINAL DEVELOPMENT PLANS
5/16/2017 4:05:51 PM
5/16/2017 4:05:51 PM
G:\2017\17-26 Legacy Auto\4 Revit\LEGACY AUTO_CENTRAL v17.rvt
FDP-A4.1
DEVELOPMENT PLANS
EXTERIOR
ELEVATIONS -
EXISTING BUILDING
LEGACY AUTO
1845 NORTH COLLEGE
FORT COLLINS, CO 80524
FINAL DEVELOPMENT PLANS
2017-26
AG
JL
4 1/4" = 1'-0"
EXISTING - NORTH ELEVATION
3 1/4" = 1'-0"
EXISTING - SOUTH ELEVATION
2 1/4" = 1'-0"
EXISTING - WEST ELEVATION
1 1/4" = 1'-0"
EXISTING - EAST ELEVATION