Loading...
HomeMy WebLinkAbout112 W. MAGNOLIA STREET PARKING LOT - PDP - PDP160040 - CORRESPONDENCE - STAFF'S PROJECT COMMENTSCommunity Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com/developmentreview January 06, 2017 Cara Scohy CS DESIGN, INC. 2519 S. Shields St #129 Fort Collins, CO 80526 RE: 112 W. Magnolia Street Parking Lot, PDP160040, Round Number 1 Comment Summary: Department: Engineering Development Review Contact: Morgan Uhlman, 970-416-4334, muhlman@fcgov.com Topic: General 12/27/2016: The Traffic Signs and Pavement Marking Construction Notes are missing number 7: 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. Comment Number: 1 Comment Originated: 12/27/2016 12/27/2016: There needs to be a reference to two benchmarks, General Notes #40. Comment Number: 2 Comment Originated: 12/27/2016 12/27/2016: Please add a legend to all the sheets of the plan set. Comment Number: 3 Comment Originated: 12/27/2016 12/27/2016: Add the limits of street cut notes to sheet C2.0, C4.0. Street Cut Note: Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering Inspector. All repairs to be in accordance with City street repair standards. Comment Number: 4 Comment Originated: 12/27/2016 12/27/2016: This project is responsible for dedicating any right-of-way and easements that are necessary or required by the City for this project. This shall including the standard utility easements that are to be provided behind the right-of-way, 15 foot along an arterial, 8 foot along an alley, 9 foot along all other street classifications. This can be done in the platting process or through separate document if the lot will not be platted. A variance to the LCUASS standard can be requested (LCUASS 1.9.4) but it may or may not be approved. Information on the dedication process can be found at: http://www.fcgov.com/engineering/devrev.php Comment Number: 5 Comment Originated: 12/27/2016 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Meaghan Overton, at 970-416-2283 or moverton@fcgov.com. Page 1 of 8 12/27/2016: The applicant will need to obtain access permits from CDOT for closing the access point on S College Ave. Comment Number: 6 Comment Originated: 12/27/2016 12/27/2016: On the Utility plans, please ghost the trees (or different visual with less branches) and any existing sign posts. Comment Number: 7 Comment Originated: 12/27/2016 12/27/2016: Please label the property line and easements more clearly. Comment Number: 8 Comment Originated: 12/27/2016 12/27/2016: The driveway to alleyway flare does not meet the standards in LCUASS Figure 7-11F. Comment Number: 9 Comment Originated: 12/27/2016 12/27/2016: The existing alleyway adjacent to this site will need to be assessed by the city and improvements may be necessary. Comment Number: 10 Comment Originated: 12/27/2016 12/27/2016: The driveway/alleyway material is not specified on the plan set. The driveway and alleyway need to be concrete up to the property line. Comment Number: 11 Comment Originated: 12/27/2016 12/27/2016: Curves C7 and C8 do not meet LCUASS standard 8.2.9, the minimum curb return radii is 15'. Comment Number: 12 Comment Originated: 12/27/2016 12/27/2016: LCUASS 7.7.C.1.H states that a clay cut off wall should be provided at the boundaries of the development. Comment Number: 13 Comment Originated: 12/27/2016 12/27/2016: The alleyway approach will have to be re-constructed after the installation of the underdrain system to detail 803. Comment Number: 14 Comment Originated: 12/27/2016 12/27/2016: The chase will need to be designed per detail D-10B. Comment Number: 15 Comment Originated: 12/27/2016 12/27/2016: On sheet C4.0, construction note 13 is too specific in dimensions. 2' Saw cut is not allowed, please follow the patching and reconstruction requirements in LCUASS chapter 25. Comment Number: 16 Comment Originated: 12/27/2016 12/27/2016: Need to detail the sidewalk connection on the east side of the driveway to show how this will meet ADA requirements. Comment Number: 17 Comment Originated: 12/27/2016 12/27/2016: There can not be more than 750sqft of water draining over the sidewalk. Comment Number: 18 Comment Originated: 12/27/2016 12/27/2016: On the drainage plans, where is design point E and Basin E1? Comment Number: 19 Comment Originated: 12/27/2016 12/27/2016: On detail sheet, remove detail 708 and 709. Comment Number: 20 Comment Originated: 12/27/2016 12/27/2016: On detail sheet, need to add 7-11F, 1601, 1602, 1607, 2201, 701, 803, D-10B Comment Number: 21 Comment Originated: 12/27/2016 Page 2 of 8 12/27/2016: See redlines for additional comments. Please return redlines with next round submittal. Comment Number: 22 Comment Originated: 12/27/2016 Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com Topic: General 01/06/2017: The project owes an additional $71 for the TDRFees. This is based on the site being .72 acres. Comment Number: 23 Comment Originated: 01/06/2017 Department: Environmental Planning Contact: Rebecca Everette, 970-416-2625, reverette@fcgov.com Topic: General 12/15/2016: The tree protection plan notes that there are 16 existing trees on the site, but there only appear to be 9 shown on the plans. Please update/clarify. Comment Number: 1 Comment Originated: 12/15/2016 12/15/2016: No additional comments, though I will review any updates to the tree protection/mitigation plan as needed. Comment Number: 2 Comment Originated: 12/15/2016 Department: Forestry Contact: Molly Roche, , mroche@fcgov.com Topic: Landscape Plans 01/04/2017: Please schedule a site visit with the City Forester to obtain Tree Inventory and Mitigation information to include on the Landscape Plans. Comment Number: 1 Comment Originated: 01/05/2017 01/04/2017: Please replace the existing Permit Box note with the correct Required Street Tree note, which is placed in a bolded box. This is available from the City Forester. Comment Number: 2 Comment Originated: 01/05/2017 01/04/2017: Please explore widening the parking lot island widths, if at all possible. The City Forester suggests Regal Prince Oak or Prairie Sentinel Hackberry as alternative species that would fit better in these narrow spaces. Comment Number: 3 Comment Originated: 01/05/2017 01/04/2017: Please consider using Red Barron Crabapple where Adirondack Crabapples are currently proposed. Red Barron will likely have better availability. Comment Number: 4 Comment Originated: 01/05/2017 01/04/2016: Please explore using Linden in place of Honeylocust, due to their adaptability to shade. Comment Number: 5 Comment Originated: 01/05/2017 Department: Light And Power Contact: Coy Althoff, , CAlthoff@fcgov.com Topic: General Page 3 of 8 01/03/2017: Light & Power have existing facilities in this area. There is primary 3-phase power available in the alley way east of this property as well as streetlight and flood light circuits along Magnolia St. and College Ave. Comment Number: 1 Comment Originated: 01/03/2017 01/03/2017: The existing 400W HPS light on the north-central part of this property is part of the Fort Collins Light & Power "floodlight" program. At this time, the monthly fee is part of the Wells Fargo utility bill. Please contact Light & Power, Project Engineering to have this structure removed prior to demolition. Comment Number: 2 Comment Originated: 01/03/2017 01/03/2017: As your project begins to move forward please contact Light and Power Engineering to coordinate the streetlight, transformer and electric meter locations, please show the locations on the utility plans. Comment Number: 3 Comment Originated: 01/03/2017 01/03/2017: Please provide a one line diagram and a C-1 form to Light and Power Engineering. The C-1 form can be found at: http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1Form.pdf Comment Number: 4 Comment Originated: 01/03/2017 01/03/2017: You may contact FCU Light & Power, project engineering if you have questions. (970) 221-6700. You may reference Light & Power’s Electric Service Standards at http://www.fcgov.com/utilities/img/site_specific/uploads/ElectricServiceStandards_F INAL_17June2016.pdf You may reference our policies, development charge processes, and use our fee estimator at http://www.fcgov.com/utilities/business/builders-and-developers. Comment Number: 5 Comment Originated: 01/03/2017 Department: PFA Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org Topic: General 12/12/2016: NO COMMENT PFA has no comment related to improvement of the parking lot at 112 W. Magnolia. Comment Number: 1 Comment Originated: 12/12/2016 Department: Planning Services Contact: Meaghan Overton, 970-416-2283, moverton@fcgov.com Topic: General 01/03/2017: It would be helpful if the site and landscape plans were larger. Right now it’s difficult to see the detail. Comment Number: 1 Comment Originated: 01/03/2017 01/04/2017: Per street maintenance - please remove drive on College and replace with sod/turf or similar. Comment Number: 7 Comment Originated: 01/04/2017 Topic: Landscape Plans 01/03/2017: Please cross-reference the legend on the landscape plan with the plant schedule. I can’t easily tell how many of each species are shown on the landscape plan the way it’s currently organized. Comment Number: 2 Comment Originated: 01/03/2017 Page 4 of 8 01/03/2017: The existing trees need to be more clearly shown. The tree notes show 16 trees, but the existing landscape plan only shows 9 trees. Where are the other 7 trees? In particular, the deciduous trees are hard to see because the linework overlaps. Any trees removed from the site should be noted as such along with detail for mitigation. Comment Number: 3 Comment Originated: 01/03/2017 Topic: Modification of Standard 01/03/2017: The justification for the modification of standard should focus more on why the proposed solutions meet the general purpose of the standard in 3.2.2(J) "equally well or better than" a plan that complied with the standard. The justification as written emphasizes the impact to the parking lot, not how well the proposed solution meets the purpose of the standard. Also note that the 15 foot setback applies only to the College Avenue side of the parking lot. The setback from the alley only needs to be a minimum of 5 feet. Comment Number: 5 Comment Originated: 01/03/2017 01/03/2017: Staff's analysis of the requested modification of standard will consider the consistency of the setback with the adjacent building to the north, the efficacy and aesthetic compatibility of the materials chosen for screening, and the movement of pedestrians around the site (e.g. the closure of the College Avenue access point). Please address these points in your revised modification request. Comment Number: 6 Comment Originated: 01/03/2017 Department: Stormwater Engineering Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com Topic: Construction Drawings 12/30/2016: The grading plan should be reconfigured such that runoff will infiltrate into the paver sections and not bypass the pavers at an unknown rate into the public street. The proposed u-channel is actually the low point for one of the paver sections, which means that an unspecified amount of runoff is going to simply escape through the u-channel. This channel should either be eliminated or modified so that it is not at the low point. Comment Number: 2 Comment Originated: 12/30/2016 12/30/2016: The underdrains don’t appear to be located at the low end of the paver sections. This should be revised. Comment Number: 3 Comment Originated: 12/30/2016 12/30/2016: The drainage plan includes a table for each paver section and run-on ratios. Please label each paver section in the plan view so I know which one is which. In addition, the run-on area for each paver section will need to be shown on an exhibit that is included within the drainage report. Currently, the run-on areas are not clear. Comment Number: 4 Comment Originated: 12/30/2016 Topic: Drainage Report 12/30/2016: Please note that Table RO-11 from the FCSCM should be referenced and utilized for runoff coefficients instead of Table RO-3 from the USDCM. Comment Number: 5 Comment Originated: 12/30/2016 12/30/2016: The 100-year orifice calculations need to be included in the report. Comment Number: 6 Comment Originated: 12/30/2016 Page 5 of 8 12/30/2016: The UD-Detention spreadsheet uses Denver rainfall data to calculate runoff and therefore detention volume. We don’t allow this spreadsheet to compute detention volume. Please put together your own mass-balance spreadsheet, using Fort Collins rainfall data and following the requirements of Chapter 10, Section 3.2.3. Comment Number: 7 Comment Originated: 12/30/2016 12/30/2016: The UD-Detention spreadsheet can be utilized for stage storage computations but I can’t tell how you’re including only the void space volume in the paver sub-grade. You should be assuming a 30% void space and this should be stated in the report. Also, the elevations shown on this spreadsheet need to be related back to the paver sub-grade section so I can verify that the detention volume is within the rock layer of the sub-grade and/or verify that the 12-inch depth of this layer is adequate. Comment Number: 8 Comment Originated: 12/30/2016 Contact: Heidi Hansen, 970-221-6854, hhansen@fcgov.com Topic: Floodplain 01/03/2017: Per the Floodplain Review Checklist, please add and label the 100-year floodplain and floodway boundaries on the Site Plan. Comment Number: 9 Comment Originated: 01/03/2017 01/03/2017: Staff will provide comments on the Floodplain Use Permit separately. The floodplain use permit with no-rise certification must be approved prior to construction. An as-built survey will be required after construction for no-rise recertification. Comment Number: 10 Comment Originated: 01/03/2017 Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com Topic: Erosion Control 12/20/2016: The site disturbs more than 10,000 sq. ft., therefore Erosion and Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials Submitted do not meet requirements. Please submit; an Erosion Control Plan (Based upon redlines), an Erosion Control Report, and an Escrow / Security Calculation. If you need clarification concerning the erosion control section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Comment Number: 1 Comment Originated: 12/20/2016 Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Construction Drawings 01/03/2017: Please change the titles so they match the other plan sets. See redlines. Comment Number: 9 Comment Originated: 01/03/2017 Page 6 of 8 01/03/2017: The City has moved to the NAVD88 vertical datum, and as of January 1, 2015, all projects are required to be on NAVD88 datum. Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX’. Comment Number: 10 Comment Originated: 01/03/2017 01/03/2017: Please revise the legal description as marked. See redlines. Comment Number: 11 Comment Originated: 01/03/2017 01/03/2017: All benchmark statements must match on all sheets. Comment Number: 12 Comment Originated: 01/03/2017 01/03/2017: There are line over text issues. See redlines. Comment Number: 13 Comment Originated: 01/03/2017 Topic: Landscape Plans 01/03/2017: Please revise the legal description in the title block as marked. See redlines. Comment Number: 5 Comment Originated: 01/03/2017 01/03/2017: There are line over text issues. See redlines. Comment Number: 6 Comment Originated: 01/03/2017 Topic: Lighting Plan 01/03/2017: Please revise the legal description in the title block as marked. See redlines. Comment Number: 7 Comment Originated: 01/03/2017 01/03/2017: Please change the titles so they match. See redlines. Comment Number: 8 Comment Originated: 01/03/2017 Topic: Site Plan 01/03/2017: Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See redlines. Comment Number: 1 Comment Originated: 01/03/2017 01/03/2017: Please revise the legal description as marked. See redlines. Comment Number: 2 Comment Originated: 01/03/2017 Page 7 of 8 01/03/2017: There are notes with missing text. See redlines. Comment Number: 3 Comment Originated: 01/03/2017 01/03/2017: There are line over text issues. See redlines. Comment Number: 4 Comment Originated: 01/03/2017 Department: Traffic Operation Contact: Nicole Hahn, 970-221-6820, nhahn@fcgov.com Topic: General 01/03/2017: Work with engineering staff to determine scope of alley improvements. Comment Number: 1 Comment Originated: 01/03/2017 01/03/2017: Consider adding some type of connection to the College Ave. sidewalk to improve pedestrian connectivity. Comment Number: 2 Comment Originated: 01/03/2017 Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General 01/03/2017: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Comment Number: 1 Comment Originated: 01/03/2017 Department: Water-Wastewater Engineering Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com Topic: Construction Drawings 12/30/2016: There is an existing 4-inch waterline in Magnolia and a 6-inch sanitary sewer main in the alley that are not shown on your plans. Please include these and make sure to survey the depth of the sanitary sewer main to ensure no conflict with the proposed storm pipe that crosses it. Comment Number: 1 Comment Originated: 12/30/2016 Topic: Landscape Plans 12/30/2016: How are you planning to irrigate the landscaping on this project? If you plan to have an irrigation tap and meter, these need to be shown on the Landscape Plan and Utility Plan with the tap size and location shown and any roadway excavation limits also shown. Comment Number: 2 Comment Originated: 12/30/2016 Department: Zoning Contact: Marcus Glasgow, 970-416-2338, mglasgow@fcgov.com Topic: General 12/21/2016: Site and landscape plan will to be on a larger scale. Comment Number: 1 Comment Originated: 12/21/2016 Page 8 of 8