Loading...
HomeMy WebLinkAbout626 S. WHITCOMB FOUR-PLEX - PDP/FDP - FDP140023 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS (10)SHEET NO. INDEX OF SHEETS 1 COVER SHEET 2 CONSTRUCTION NOTES 3 DEMOLITION & UTILITY PLANS 4 GRADING, DRAINAGE & EROSION CONTROL PLANS 5 DETAILS 2.) # 1-11; NGVD 29 Elevation = 5005.44 (NAVD 88 Elevation = 5008.62); Southeast Corner of Mulberry Street and Loomis Avenue, at the Northeast Corner of a Concrete Traffic Equation to get from NGVD 29 to NGVD 88= NAVD 29 + 3.175' (Average). Signal Base. 1.) NGS F 3- In Fort Collins, At the intersection of Howe and Laurel Streets, 54.9 meters (180.1ft.) West of the centerline of Howe Street, 10.1 meters (33.1 ft.) South of the centerline of Laurel Street, 2.1 meters (6.9 ft) north of the North edge of a sidewalk, 2.0 meters (6.6 ft) East of the center of a 36-inch elm tree, and 1.1 meters (3.6 ft.) South of the south curb of Laurel Street. note--the disk is unstamped. The mark is above level with Laurel Street. BENCHMARK: ELEVATIONS SHOWN ON ATTACHED GRADING PLAN AND DRAINAGE CONTROL PLAN ARE BASED ON CITY OF FORT COLLINS VERTICAL DATUM AND ARE REFERENCED THE CITY OF FORT COLLINS. 17 APRIL 2015 626 SOUTH WHITCOMB STREET PROJECT NUMBER LARIMER, STATE OF COLORADO LOT 23, BLOCK 76, CITY OF FORT COLLINS, COUNTY OF 626 SOUTH WHITCOMB UTILITY PLANS FOR TWO ADDITIONAL UNITS ADDED TO EXISTING DUPLEX SHEET 1 OF 5 DATE: MARCH 5, 2015 City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: City Engineer Water and Wastewater Utility Stormwater Utility Parks & Recreation Traffic Engineer Date CHECKED BY: Date CHECKED BY: Date CHECKED BY: Date CHECKED BY: Date CHECKED BY: Date 2 OF 5 DA KGL CONSTRUCTION NOTES SHEET JOB DRAWN DATE CHECKED REVISIONS DRAWING 422 EAST OAK FT COLLINS, COLORADO 80524 (970) 484-0306 ARCHITECTURAL ENGINEERS, LLC ANDERSON ASSOCIATES AA 14-104 Proposed Duplex Addition to Existing @ 626 S. Whitcomb Street Fort Collins, Colorado 80524 Rodney & Jamie Rice- Owners City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: City Engineer Date CHECKED BY: Water & Wastewater Utility Date CHECKED BY: Stormwater Utility Date CALL UTILITY NOTIFICATION CENTER OF COLORADO ÄÄÄ  CALL 2- BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Dennis R. Messner, P.E. Consulting Civil Engineer 1355 N. Cleveland Ave, Ste. #1 Loveland, CO. 80527 Telephone: (970) 461-3501 Mobile: (970) 402-4360 E-mail: dennis@messnereng.com 17 APRIL 2015 SCALE: 1" = 10'-0" NORTH 1 1 UTILITY PLAN PROPOSED DUPLEX ADDITION PHONE PEDESTAL EXISTING ELEC. NEW NEW ELECTRICAL TRANSFORMER WATER 3/4" WATER SERVICE ABANDONE EXISTING NEW 1 1/4" NEW 1" NEW 3/4" EXISTING NEW 1 1/4" APPROXIMATE LOCATION OF (EX.) SANITARY SEWER SERVICE (NOT FIELD VERIFIED) TO REMAIN & NEW SEWER CONNECTED. CONTRACTOR TO VERIFY LOCATION OF (EX.) SEWER PIPE TO CONNECTING NEW SEWER TO EXISTING. EXISTING 8" SEWER MAIN MANHOLE LOCATION- 50' NORTH OF NORTH PROPERTY LINE MANHOLE LOCATION- 50' SOUTH OF SOUTH PROPERTY LINE IN ALLEY NOTE: SEE VICINITY MAP FOR FIRE HYDRANT LOCATIONS w/ VALVES DIRECTION OF FLOW UPPER & LOWER UNITS TO BE SERVED w/ SEPARATE UPPER UNIT SERVICE FOR UPPER & LOWER UNITS w/SEPARATE ELEC. METERS NEW SERVICE FOR ELEC. METERS (NOTE: NEW LOWER UNIT) FINISH FLOOR = 5009.00 = 100'-0" EXISTING ONE STORY DUPLEX WITH BASEMENT FINISH FLOOR = 5008.58 FIN FLR=5006.05=97'-0 5/8" BIKE STORAGE EXISTING CONCRETE PAN PROPOSED 4'-6" WIDE CONCRETE WALK 5' MIN. EXISTING UTILITIES (LIGHT DASHED LINES) NEW UTILITY INSTALLATION ( HEAVY SOLID LINES) LEGEND SCALE: 1" = 10'-0" NORTH PORCH PROPOSED DUPLEX ADDITION EXISTING LAWN EXISTING LAWN GRADING PLAN 2 2 5005(E) FINISH FLOOR = 5009.00 = 100'-0" EXISTING ONE STORY DUPLEX WITH BASEMENT FINISH FLOOR = 5008.58 97'-05/8" EXISTING CONCRETE PAN PROPOSED 4'-6" WIDE CONCRETE WALK 5005(P) 5005(P) 5004(P) 5004(P) 5005(P) 5005(P) PROPOSED PERMEABLE PAVEMENT PAVEMENT PROPOSED CURB HIGH (EX.) CONCRETE DRIVE TO REMAIN (EX.) CONCRETE WALK TO REMAIN (EX.) CONCRETE PROPOSED CONCRETE PAVER ASPHALT FINES CRUSHER PATIO FINES CRUSHER PATIO & WALK PROPOSED BIKE STORAGE FIN FLR=5006.05= CONCRETE PAVER RETAINER (EX.) CONCRETE PAVEMENT DISCHARGE LINE PROPOSED 6" PVC PERMEABLE RETAINER-FLUSH WITH PAVEMENT 6" PVC PIPE RISER w/ 6" PVC TO EXTEND THROUGH 8" WIDE CONC. RETAINING WALL RETAINING WALL TOP OF WALL= ELEV. 04.50 F L OF 6" PVC= ELEV. 03.65 10'-0" PROPOSED WALK TO REMAIN EXISTING DRAINAGE PATTERN TO BE RETAINED 04.95 INV. 6" CLEAN-OUT 5 OF 5 DA KGL DETAILS SHEET JOB DRAWN DATE CHECKED REVISIONS DRAWING 422 EAST OAK FT COLLINS, COLORADO 80524 (970) 484-0306 ARCHITECTURAL ENGINEERS, LLC ANDERSON ASSOCIATES AA 14-104 Proposed Duplex Addition to Existing @ 626 S. Whitcomb Street Fort Collins, Colorado 80524 Rodney & Jamie Rice- Owners City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: City Engineer Date CHECKED BY: Water & Wastewater Utility Date CHECKED BY: Stormwater Utility Date CALL UTILITY NOTIFICATION CENTER OF COLORADO ÄÄÄ  CALL 2- BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. 17 APRIL 2015 Dennis R. Messner, P.E. Consulting Civil Engineer 1355 N. Cleveland Ave, Ste. #1 Loveland, CO. 80527 Telephone: (970) 461-3501 Mobile: (970) 402-4360 E-mail: dennis@messnereng.com CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. VEHICLE TRACKING CONTROL (DETAIL SW-14) IS REQUIRED IF ACCESS TO CONCRETE WASHOUT AREA IS OFF PAVEMENT. SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT AN ACCEPTED WASTE SITE. WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. NOTES: 1. 2. 3. 4. 5. 6. 3H:1V OR FLATTER SIDE SLOPES 12" MIN 8'x 8' MIN OR AS REQUIRED TO CONTAIN WASTE CONCRETE 12" 2'-0" MIN. COMPACTED EMBANKMENT MATERIAL, TYP. BERM AROUND PERIMETER GROUND SURFACE SIGN TO INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA FLOW 3'-4' ADJACENT ROLLS SHALL TIGHTLY ABUT W1 NOTES: INSTALLATION: WHEN INSTALLING RUNNING LENGTHS OF WATTLES, BUTT THE SECOND WATTLE TIGHTLY AGAINST THE FIRST, DO NOT OVERLAP THE ENDS. STAKE THE WATTLES AT EACH END AND FOUR FOOT ON CENTER. FOR EXAMPLE: A 25 FOOT WATTLE USES 6 STAKES A 20 FOOT WATTLE USES 5 STAKES A 12 FOOT WATTLE USES 4 STAKES STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF THE WATTLE. LEAVING 2 - 3 INCHES OF THE STAKE PROTRUDING ABOVE THE WATTLE. A HEAVY SEDIMENT LOAD WILL TEND TO PICK THE WATTLE UP AND COULD PULL IT OFF THE STAKES IF THEY ARE DRIVEN DOWN TOO LOW. IT MAY BE NECESSARY TO MAKE A HOLE IN THE WATTLE WITH A PICK END OF YOUR MADDOX IN ORDER TO GET THE STAKE THROUGH THE STRAW. WHEN STRAW WATTLES ARE USED FOR FLAT GROUND APPLICATIONS, DRIVE THE STAKES STRAIGHT DOWN; WHEN INSTALLING WATTLES ON SLOPES, DRIVE THE STAKES PERPENDICULAR TO THE SLOPE. DRIVE THE FIRST END STAKE OF THE SECOND WATTLE AT AN ANGLE TOWARD THE FIRST WATTLE IN ORDER TO HELP ABUT THEM TIGHTLY TOGETHER. IF YOU HAVE DIFFICULTY DRIVING THE STAKE INTO EXTREMELY HARD OR ROCKY SLOPES, A PILOT BAR MAY BE NEEDED TO BEGIN THE STAKE HOLE. 1"x 1" WOOD STAKES 18"-24" BAILING WIRE OR NYLON ROPE WATTLE "A" WATTLE "B" 1' 2' TYP. 1' 1' W2 NOTES: INSTALLATION: STAKES SHOULD BE DRIVEN ACROSS FROM EACH OTHER AND ON EACH SIDE OF THE WATTLE. LEAVING 4"-6" OF STAKE PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR NYLON ROPE SHOULD BE TIED TO THE STAKES ACROSS THE WATTLE. STAKES SHOULD THEN BE DRIVEN UNTIL THE BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG TO THE WATTLE. WHEN INSTALLING RUNNING LENGTHS OF WATTLES, TO PREVENT SHIFTING, BUTT THE SECOND WATTLE TIGHTLY AGAINST THE FIRST. DO NOT OVERLAP THE ENDS. STAKES SHOULD BE DRIVEN 1 FT. FROM END, ACROSS FROM AND ON EACH SIDE OF WATTLE LEAVING 4"-6" OF STAKE PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR NYLON ROPE SHOULD BE TIED TO STAKES IN AN HOUR GLASS FORMATION (FRONT TO BACK OF WATTLE "A", ACROSS TO FRONT OF WATTLE "B", ACROSS TO BACK AND BACK TO FRONT OF WATTLE "A"). STAKES SHOULD THEN BE DRIVEN IN UNTIL BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG TO THE WATTLE. SEDIMENT DEPOSITION ZONE STORM WATER LINE WEIGHTED WATTLE LIP OF GUTTER SIDEWALK EXISTING OR PROPOSED INLET TOP BACK CURB FLOW LINE SEDIMENT DEPOSITION ZONE STORM WATER LINE LIP OF GUTTER WEIGHTED WATTLE AT 45 DEG. TO CURB SIDEWALK TOP BACK CURB FLOW LINE SIDEWALK TOP BACK CURB FLOW LINE W4 NOTES: 1. NUMBER OF WATTLES AND SPACING SHOULD BE DETERMINED BY THE SLOPE AND SITE CONDITIONS. 2. TUBULAR MARKERS SHALL MEET THE REQUIREMENTS OF MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) 3. CITY RECOMMENDS INSTALLING AT LEAST 3 CHECKDAMS WHEN USING THIS SETUP. LIP OF GUTTER WEIGHTED WATTLE W1 & W2 INSTALLATION NOTES: 1. THE LOCATION AND LENGTH OF WATTLE IS DEPENDENT ON THE CONDITIONS OF EACH SITE. 2. WATTLES SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES. 3. WATTLES SHALL CONSIST OF STRAW, COMPOST, EXCELSIOR, OR COCONUT FIBER. 4. NOT FOR USE IN CONCENTRATED FLOW AREAS. 5. THE WATTLES SHALL BE TRENCHED INTO THE GROUND A MINIMUM OF TWO (2) INCHES. 6. WATTLES SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. 7. ON SLOPES, WATTLES SHOULD BE INSTALLED ON CONTOUR WITH A SLIGHT DOWNWARD ANGLE AT THE END OF THE ROW IN ORDER TO PREVENT PONDING AT THE MID SECTION. 8. RUNNING LENGTHS OF WATTLES SHOULD BE ABUTTED FIRMLY TO ENSURE NO LEAKAGE AT THE ABUTMENTS. 9. SPACING - DOWNSLOPE: VERTICAL SPACING FOR SLOPE INSTALLATIONS SHOULD BE DETERMINED BY SITE CONDITIONS. SLOPE GRADIENT AND SOIL TYPE ARE THE MAIN FACTORS. A GOOD RULE OF THUMB IS: 1:1 SLOPES = 10 FEET APART 2:1 SLOPES = 20 FEET APART 3:1 SLOPES = 30 FEET APART 4:1 SLOPES = 40 FEET APART, ETC. HOWEVER, ADJUSTMENTS MAY HAVE TO BE MADE FOR THE SOIL TYPE: FOR SOFT, LOAMY SOILS - ADJUST THE ROWS CLOSER TOGETHER; FOR HARD, ROCKY SOILS - ADJUST THE ROWS FURTHER APART. A SECONDARY WATTLE PLACED BEHIND THE ABUTMENT OF TWO WATTLES IS ENCOURAGED ON STEEP SLOPES OR WHERE JOINTS HAVE FAILED IN THE PAST. 10. STAKING: THE CITY RECOMMENDS USING WOOD STAKES TO SECURE THE WATTLES. 1/2" TO 5/8" REBAR IS ALSO ACCEPTABLE. BE SURE TO USE A STAKE THAT IS LONG ENOUGH TO PROTRUDE SEVERAL INCHES ABOVE THE WATTLE: 18" IS A GOOD LENGTH FOR HARD, ROCKY SOIL. FOR SOFT LOAMY SOIL USE A 24" STAKE. 4"-6" ABOVE WATTLE AFTER BAILING WIRE OR NYLON ROPE IS ATTACHED. STAKES NEED TO BE TAMPED UNTIL WIRE/ROPE IS SNUG WITH WATTLE. W3 NOTE: IF THE AREA BEHIND THE INLET IS NOT STABILIZED, A BMP SHOULD BE USED TO PREVENT SEDIMENT FROM ENTERING THE INLET 1"x 1" WOOD STAKES 18"-24" THE CONTRACTOR SHALL INSPECT WATTLES EVERY TWO WEEKS AND AFTER ANY SIGNIFICANT STORM EVENT AND MAKE REPAIRS OR REMOVE SEDIMENT ACCUMULATED BEHIND WATTLE AS NECESSARY. SEDIMENT ACCUMULATED BEHIND WATTLE SHALL BE REMOVED WHEN THE SEDIMENT HAS ACCUMULATED TO ONE HALF THE DIAMETER OF THE WATTLE. WATTLES SHALL REMAIN IN PLACE UNTIL THE UPSTREAM DISTURBED AREA IS STABILIZED AND IS ACCEPTED BY THE CITY. WATTLE MAINTENANCE NOTES: 1. 2. 3. ENDS SHALL ABUT TIGHTLY TO BACK OF CURB END SHALL ABUT TIGHTLY TO BACK OF CURB ENDS OF ADJACENT WATTLES SHALL BE TIGHTLY ABUTTED TO PREVENT SEDIMENT BYPASS 4' MAX. SEDIMENT DEPOSITION ZONE W2 NOTE: ONLY WATTLES MADE WITH COCONUT FIBERS SHALL BE USED WHEN INSTALLATION COMES IN CONTACT WITH A WATER BODY. SIDEWALK CULVERT/CHASE/PAN W3, W4 & W5 NOTES: 1. WHEN USING STRAW WATTLE, THE STRAW WATTLE MUST HAVE A WEIGHTED CORE. 2. ALL PRODUCTS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS. 3. OTHER PRODUCTS MAY BE USED IN PLACE OF WEIGHTED WATTLES UPON WRITTEN APPROVAL FROM THE CITY. NOTE: A COPY OF DETAILS AND SPECIFICATIONS WILL NEED TO BE INCORPORATED INTO THE SWMP. END SHALL TIGHTLY ABUT TO BACK OF CURB SEDIMENT DEPOSITION ZONE TUBULAR MARKER EXISTING OR PROPOSED INLET END SHALL TIGHTLY ABUT TO BACK OF CURB $#44+'45'%6+10 065 CONCRETE PERIMETER BARRIER SEPARATOR FABRIC US-250 WOVEN GEOTEXTILE %10%4'6'2'4+/'6'4 12" min. 6" %74$5'%6+10 065 CONCRETE PERIMETER CURB SEPARATOR FABRIC US-250 WOVEN GEOTEXTILE %10%4'6'2'4+/'6'4 18" min. 6" 6" Undisturbed Soil Swale Topsoil Separator Fabric US-250 Woven Geotextile The Above Detail Has Been Modified to Reflect the Specific Requirements For The Duplex Addition At 626 Whitcomb St., Fort Collins, Colorado 80524 2'4/'#$.'2#8'/'065'%6+10 065 2" Bedding Layer of Crushed #8 Rock Minimum 4" Layer of #57 Base Minimum 20" Layer of #2 Rock Sub-Base Interlocking Concrete Edge Restraint Pavers 1 8" Hand-Tight Joints 6" dia. Perforated PVC Pipe Sub-drain 6" R.D. 65'+/- OF 6" PVC @ SLOPE= 0.50% 04.60 INV 6" EXTEND 6" PVC THROUGH CURB & INSTALL SLOTTED CAP ON PIPE. PROPOSED 6" PVC, min 6" COVER, CONNECT ROOF DOWNSPOUTS 6" R.D. SCALE: 1" = 10'-0" NORTH PROPOSED DUPLEX ADDITION DRAINAGE & EROSION CONTROL PLAN 2 1 5005(E) FINISH FLOOR = 5009.00 = 100'-0" EXISTING ONE STORY DUPLEX WITH BASEMENT FINISH FLOOR = 5008.58 97'-05/8" EXISTING CONCRETE PAN PROPOSED 4'-6" WIDE CONCRETE WALK 5005(P) 5005(P) 5004(P) 5004(P) 5005(P) 5005(P) PROPOSED PERMEABLE PAVEMENT PAVEMENT SCL SCL WATTLE APPLICATION WATTLE APPLICATION CONCRETE WASHOUT AREA CWA SCL SCL ASPHALT FINES CRUSHER PATIO FINES CRUSHER PATIO & WALK PROPOSED BIKE STORAGE FIN FLR=5006.05= PROPOSED 6" INV. ELEV. 01.68 CAP FOR ACCESS 6" PVC PIPE w/ PVC FITTINGS TOP OF RETAINING WALL ELEV. = 04.50 6" INV. ELEV.= 03.65 EXIST. ALLEY BOTTOM ELEV. 8" 7.8" 10.2" PAVEMENT CROSS SECTION A-A PROPERTY LINE 4'-6" CONCRETE SIDEWALK @ 1/4" PER FT. BERM N.T.S. RETAINING WALL SECTION N.T.S. 2- #4 REBAR LATERAL @ TOP & BOTTOM 6" DIA. PVC PIPE RISER N.T.S. 8" 18" 4" 1'-3" EARTHEN 4 OF 5 DA KGL GRADING, DRAINAGE & EROSION CONTROL SHEET JOB DRAWN DATE CHECKED REVISIONS DRAWING 422 EAST OAK FT COLLINS, COLORADO 80524 (970) 484-0306 ARCHITECTURAL ENGINEERS, LLC ANDERSON ASSOCIATES AA Proposed Duplex Addition to Existing @ 626 S. Whitcomb Street Fort Collins, Colorado 80524 Rodney & Jamie Rice- Owners Dennis R. Messner, P.E. Consulting Civil Engineer 1355 N. Cleveland Ave, Ste. #1 Loveland, CO. 80527 Telephone: (970) 461-3501 Mobile: (970) 402-4360 E-mail: dennis@messnereng.com PLANS 17 APRIL 2015 City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: City Engineer Date CHECKED BY: Water & Wastewater Utility Date CHECKED BY: Stormwater Utility Date CALL UTILITY NOTIFICATION CENTER OF COLORADO ÄÄÄ  CALL 2- BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. B A 0.119 2 1 0.074 3 0.024 14-104 NEW ELECTRIC & TELEPHONE TO BE IN COMMON TRENCH, 3'0" FROM ADJACENT PROPERTY LINE. LINES TO BE (EX.) UTILITY VACATED LINES TO BE (EX.) UTILITY VACATED EXISTING NEW (2" EMPTY CONDUIT FOR COMCAST) FOR COMCAST, A NEW 2" PVC PROVIDED FROM THE ALLEY TO THE EAST SIDE OF ADDITION. AT EAST SIDE OF ADDITION A 12" X 18" (8" DEEP) BOX SUPPLIED BY COMCAST TO BE MOUNTED 3'0" ABOVE GRADE, ACCEPTING THE 2" CONDUIT. COORDINATE WITH DON KAPPERMAN- COMCAST- (970) 567-0245. 50 L.F. OF NEW 2" PVC FOR UNDERGROUNDING FUTURE UTILITY LINE ALONG ALLEY FRONTAGE. (ALL UTILITIES ARE UNDERGROUND) PROPOSED PANEL METER PROPOSED WATER SERVICE LINE TO BE BORED UNDER EXISTING CONCRETE DRIVEWAY. EXISTING CONCRETE DRIVEWAY TO BE RETAINED. X X X X X X X X X X X X SCALE: 1" = 10'-0" NORTH DEMOLITION PLAN 1 2 REMOVE FENCE 51" COTTONWOOD REMOVED 7" ELM REMOVED REMOVE MULTI-STEM ASH 58" COTTONWOOD REMAINS 43" COTTONWOOD REMAINS X X REMOVE FENCE REMOVE CONCRETE APRON REMOVE 15" DIA. APPLE TREES REMOVE CONCRETE REMOVE MULTI-STEM COTTONWOOD EXISTING ONE STORY DUPLEX WITH BASEMENT FINISH FLOOR = 5008.58 EXISTING CONCRETE PAN REMOVE GARAGE & ASSOCIATED CONCRETE RETAIN EXISTING GRAVELED PARKING AREA 3 OF 5 DA KGL DEMOLITION & UTILITY PLANS SHEET JOB DRAWN DATE CHECKED REVISIONS DRAWING 422 EAST OAK FT COLLINS, COLORADO 80524 (970) 484-0306 ARCHITECTURAL ENGINEERS, LLC ANDERSON ASSOCIATES AA 14-104 Proposed Duplex Addition to Existing @ 626 S. Whitcomb Street Fort Collins, Colorado 80524 Rodney & Jamie Rice- Owners City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: City Engineer Date CHECKED BY: Water & Wastewater Utility Date CHECKED BY: Stormwater Utility Date CALL UTILITY NOTIFICATION CENTER OF COLORADO ÄÄÄ  CALL 2- BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Dennis R. Messner, P.E. Consulting Civil Engineer 1355 N. Cleveland Ave, Ste. #1 Loveland, CO. 80527 Telephone: (970) 461-3501 Mobile: (970) 402-4360 E-mail: dennis@messnereng.com 17 APRIL 2015