HomeMy WebLinkAboutLAKEVIEW ON THE RISE, AFFORDABLE HOUSING - PDP - PDP170014 - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORTPedcor Fort Collins South of the intersection of North College Avenue and Trilby Road Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Prepared for: Pedcor Investments, LLC Carmel, Indiana January 12, 2017 Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable REPORT TOPICS* PROJECT DESCRIPTION SITE CONDITIONS EXPLORATION AND TESTING PROCEDURES Field Exploration Laboratory Testing GEOTECHNICAL MODEL Laboratory Testing Corrosion Protection (Water-Soluble Sulfates) Groundwater SEISMIC CONSIDERATIONS GEOTECHNICAL OVERVIEW Expansive Soils and Bedrock Shallow Bedrock Foundation Recommendations SITE PREPARATION Demolition Ground Modification Excavation Subgrade preparation Fill Materials Compaction Requirements Utility Trench and Backfill Grading and Drainage Exterior Slab Design and Construction SHALLOW FOUNDATIONS Post-Tensioned Slabs Design Recommendations Post Tensioned Slabs Construction Considerations Spread Footings Design Recommendations Spread Footings Construction Considerations FLOOR SYSTEMS Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Floor Systems Design Recommendations Floor Systems Construction Considerations BELOW GRADE STRUCTURES Design Parameters Swimming Pool Recommendations Elevator Pit Elevator Pit Design Recommendations PAVEMENTS Pavements Subgrade Preparation Pavements Design Recommendations Pavements Construction Considerations Pavements Maintenance GENERAL COMMENTS ATTACHMENTS SITE LOCATION MAP EXPLORATION PLAN EXPLORATION RESULTS (Boring Logs and Laboratory Data) PHOTOGRAPHY LOG SUPPORTING INFORMATION (General Notes and USCS, etc.) *This is a paper rendition of a web-based Geotechnical Engineering Report. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable A geotechnical exploration has been performed for the proposed Pedcor Fort Collins project to be constructed south of the intersection of North College Avenue and Trilby Road in Fort Collins, Colorado. Eighteen (18) borings designated as Boring No. B-01 through Boring No. B-18 were performed to depths of approximately 20½ feet to 25½ feet below existing site grades in the approximate locations of the proposed buildings. Seven (7) borings designated as Boring No. P- 01 through Boring No. P-07 were performed to depths of approximately 10½ feet below existing site grades in proposed parking areas and drive lanes. Three (3) borings designated as Boring No. R-01 through Boring No. R-03 were performed to depths of approximately 20½ feet below existing site grades in the location of the proposed retention pond and had temporary piezometers installed. This report specifically addresses the recommendations for the proposed Pedcor project, including buildings, access drives and parking areas, a clubhouse, pool and other site improvements. Detailed recommendations for the design of storm water retention features and the pond are outside our scope of work. Borings performed in these areas are for informational purposes and will be utilized by others. Based on the information obtained from our subsurface exploration, the site can be developed for the proposed project. However, the following geotechnical considerations were identified and will need to be considered: Subsurface conditions encountered in our borings generally consisted of about 9 to 20 feet of lean clay with varying amounts of sand over claystone bedrock which extended to maximums depths of explorations. The upper ½ to 4½ feet of the bedrock was judged to highly weathered. Groundwater was encountered in most of our test borings at depths of about 6.6 to 20.4 feet below existing site grades when checked several days after drilling. Groundwater levels can fluctuate in response to site development and to varying seasonal and weather conditions, irrigation on or adjacent to the site and fluctuations in nearby water features. Areas of shallow bedrock were encountered in some of the borings at depths ranging from 9 to 20 feet below existing site grades. Deep utility excavations that extend into the bedrock may require heavy-duty equipment to complete excavations. Laboratory testing results indicated that expansive soils and bedrock are present on this site. In particular, swell testing indicated the upper 2 to 4 feet of lean clay soils on the northern portion of the site were moderately to highly expansive. This report provides recommendations to help mitigate the effects of soil shrinkage and expansion. It is imperative the recommendations described in the Ground Modification and Grading and Drainage sections of this report be followed to reduce the risk of movement. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable We recommend the proposed buildings be constructed on a post-tensioned slab foundation system provided the soils are over-excavated to a depth of at least 3 feet below the bottom of the slab and replaced with moisture conditioned, compacted engineered fill consisting of on-site soils. As a slightly higher risk alternative, a spread footing foundation system can be used. If a post-tensioned slab foundation is used to support the buildings, the foundation slab will also act as a floor slab. If a spread footing foundation system is used, a slab-on-grade may be utilized for the interior floor system, provided the native clay soils are over-excavated to a depth of at least 3 feet below the floor slab, moisture conditioned and recompacted. Where site grading will result in at least 6 feet of fill below the proposed building, over-excavation will not be necessary below that particular building. The amount of movement of foundations, floor slabs, pavements, etc. will be related to the wetting of underlying supporting soils. Therefore, it is imperative the recommendations discussed in the Grading and Drainage section of this report be followed to reduce potential movement. The 2012/2015 International Building Code, Table 1613.5.2 IBC seismic site classification for this site is D. Recommended pavement thicknesses for this project include 3½ inches of asphalt over 6 inches of aggregate base course in light-duty parking areas and 6 inches of asphalt 6 inches of aggregate base course in heavy-duty drive lanes and loading areas. Additional pavement section alternatives and discussion as well as recommendations for ground modification below pavements are presented in the report. Surface drainage should be designed, constructed and maintained to provide rapid removal of surface water runoff away from the proposed buildings and pavements. Water should not be allowed to pond adjacent to foundations or on pavements and conservative irrigation practices should be followed to avoid wetting foundation/slab soils and pavement subgrade. Excessive wetting of foundations/slab soils and subgrade can cause movement and distress to foundations, floor slabs, concrete flatwork and pavements. Close monitoring of the construction operations and implementing drainage recommendations discussed herein will be critical in achieving the intended foundation, slab and pavement performance. We therefore recommend that Terracon be retained to monitor this portion of the work. This summary should be used in conjunction with the entire report for design purposes. It should be recognized that details were not included or fully developed in this section, and the report must be read in its entirety for a comprehensive understanding of the items contained herein. The section titled GENERAL COMMENTS should be read for an understanding of the report limitations. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Our initial understanding of the project was provided in our proposal and was discussed in the project planning stage. Item Description Project location The site is located southeast of the intersection of North College Avenue (Highway 287) and East Trilby Road in Fort Collins, Colorado. The approximate center of the project site is 40.49043°N/105.07562°W. Proposed construction We understand the project will include multiple, multi-family housing buildings, a clubhouse, pool, access drives and parking areas, and a retention pond. Maximum loads Columns: 75 to 100 kips maximum (assumed) Walls: 2 to 3 kips per linear maximum (assumed) Slabs: 100 pounds per square foot maximum (assumed Grading A tentative grading plan was provided to us indicating cuts up to 3 feet and fill up 13 feet in some areas. Deeper cuts may be required for the swimming pool, deeper utility installation and elevator pits (if included). Below-grade construction No below-grade areas are planned for the proposed buildings. However, we anticipated the exterior swimming pool will likely extend up to about 10 feet below site grades. Pavements Based on our experience with similar projects, we estimate the follow traffic conditions: 1,450 passenger vehicle trips per day 6 bus trips per day 1 garbage truck trip per day 4 delivery truck trips per day Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable The following description of site conditions is derived from our site visit in association with the field exploration as well as our review of publically available geologic maps, topographic maps and aerial photographs. We also collected photographs of the site at the time of our field exploration program. Representative photos are provided in our Photography Log. Item Description Parcel information The site is located southeast of the intersection of North College Avenue (Highway 287) and East Trilby Road in Fort Collins, Colorado. The approximate center of the project site is N40.49043°/W105.07562°. See Site Location Existing improvements The site is currently abandoned farmland that appears to still be mowed on a semi-regular basis. An abandoned single-story bakery structure is located on the west site of the site and an irrigation ditch runs across approximately ¾ of the north side of the site. The site is bordered by North College Avenue to the west, followed by single-family residences and commercial developments. To the north and east of the site are single-family residences, undeveloped land and irrigated farmland. To the south of the site is Robert Benson Lake. Current ground cover The site is covered with mowed native grasses and weeds Existing topography The site has rolling hills, slopping gradually downward to the south of the site. Water features The site has an abandoned irrigation ditch on the north side, a small stream runs around the northeast corner and Robert Benson Lake to the south. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Based on our experience and our understanding of the project as noted in Project Understanding, we developed the following scope of services for field exploration and laboratory testing for this project. Our field exploration work included the drilling and sampling of exploratory soil borings consistent with the following schedule. Eighteen (18) borings designated as Boring No. B-01 through Boring No. B-18 were performed to depths of approximately 20½ feet to 25½ feet below existing site grades in the approximate locations of the proposed buildings. Seven (7) borings designated as Boring No. P-01 through Boring No. P-07 were performed to depths of approximately 10½ feet below existing site grades in proposed parking areas and drive lanes. Three (3) borings designated as Boring No. R-01 through Boring No. R-03 were performed to depths of approximately 20½ feet below existing site grades in the location of the proposed retention pond and had temporary piezometers installed. Proposed borings were completed to the planned depths below existing site grades or to practical auger refusal, if shallower. Number of Borings Boring Depth (ft.) Planned Location 18 20 to 25 Buildings 7 10 Pavements 3 20 Retention Pond Locations of soil borings are provided on our Exploration Plan. The locations of exploration points were established in the field by Terr a hand-held GPS unit to establish boring locations. The accuracy of the exploration points is usually within about 10 feet of the noted location. A ground surface elevation at each boring was obtained by Terracon using an referencing an on-site benchmark, the benchmark elevation was determined by using topographic maps, accurate to within about a foot. The borings were drilled with a CME-55 truck-mounted rotary drill rig with solid-stem augers. Disturbed samples were obtained at selected intervals utilizing a 2-inch outside diameter, split- spoon sampler and a 3-inch outside diameter, ring-barrel sampler. Disturbed bulk samples were obtained from auger cuttings from the top 5 feet of the pavement borings. Penetration resistance values were recorded in a manner similar to the standard penetration test (SPT). This test consists of driving the sampler into the ground with a 140-pound hammer free-falling through a distance of 30 inches. The number of blows required to advance the ring-barrel sampler 12 inches (18 inches for standard split-spoon samplers, final 12 inches are recorded) or the interval indicated, is recorded as a standard penetration resistance value (N-value). The blow count values are Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable indicated on the boring logs at the respective sample depths. Ring-barrel sample blow counts are not considered N-values. A CME automatic SPT hammer was used to advance the samplers in the borings performed on this site. A greater efficiency is typically achieved with the automatic hammer compared to the conventional safety hammer operated with a cathead and rope. Published correlations between the SPT values and soil properties are based on the lower efficiency cathead and rope method. This higher efficiency affects the standard penetration resistance blow count value by increasing the penetration per hammer blow over what would be obtained using the cathead and rope method. The effect of the automatic hammer's efficiency has been considered in the interpretation and analysis of the subsurface information for this report. The standard penetration test provides a reasonable indication of the in-place density of sandy type materials, but only provides an indication of the relative stiffness of cohesive materials since the blow count in these soils may be affected by the moisture content of the soil. In addition, considerable care should be exercised in interpreting the N-values in gravelly soils, particularly where the size of the gravel particle exceeds the inside diameter of the sampler. Our exploration team prepared field boring logs as part of the drilling operations. These field logs include visual classifications of the materials encountered during drilling and our interpretation of the subsurface conditions between samples. Groundwater measurements were obtained in the borings at the time of site exploration and several days after drilling. Final boring logs were prepared from the field logs. The final boring logs represent the engineer's interpretation of the field logs and include modifications based on observations and tests of the samples in the laboratory. The three retention pond borings had temporary piezometers installed into the boreholes in order to facilitate delayed groundwater measurements. The temporary piezometers consisted of slotted PVC pipe inserted into the borehole and covered with a steal plate. Temporary piezometers were checked several days after the completion of drilling for delayed groundwater measurements. Upon completion of delayed water-level readings, the PVC piping was removed and the boreholes were backfilled with auger cuttings. In some boreholes, the PVC piping could not be removed and instances the PVC pipe was left in the boreholes and the boreholes were backfilled with auger cuttings around the PVC pipe. All borings were backfilled immediately after groundwater measurements were obtained with auger cuttings. Excess auger cuttings were disposed of on the site by spreading in the area of each exploration point. Because backfill material often settles below the surface after a period of time, you should observe the exploration points periodically for signs of depressions and backfill them if necessary. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable The soil and bedrock samples retrieved during the field exploration were returned to the laboratory for observation by the project geotechnical engineer. At that time, the field descriptions were reviewed and an applicable laboratory testing program was formulated to determine engineering properties of the subsurface materials. Laboratory tests were conducted on selected soil and bedrock samples. The results of these tests are presented on the boring logs and in this appendix. The test results were used for the geotechnical engineering analyses, and the development of foundation and earthwork recommendations. The laboratory tests were performed in general accordance with applicable locally accepted standards. Soil samples were classified in general accordance with the Unified Soil Classification System described Supporting Information. Procedural standards noted in this report are for reference to methodology in general. In some cases, variations to methods are applied as a result of local practice or professional judgment. Water content Plasticity index Grain-size distribution Consolidation/swell Unconfined Compressive Strength Dry density R-value Water-soluble sulfate content Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable 1 Specific conditions encountered at each boring location are indicated on the individual boring logs. Stratification boundaries on the boring logs represent the approximate location of changes in soil types; in situ, the transition between materials may be gradual. Details for each of the borings can be found in Exploration Results. A discussion of field sampling and laboratory testing procedures and test results are presented in Exploration and Testing Procedures. Based on the results of the borings, subsurface conditions on the project site can be generalized as follows: Material Description Approximate Depth to Bottom of Stratum Consistency/Density/Hardness Lean clay with varying amounts of sand About 9 to 20 feet below existing site grades. Soft to very stiff Claystone bedrock To the maximum depth of exploration of about 25½ feet. Weathered to very hard. Representative soil samples were selected for swell-consolidation testing and exhibited 0.8 percent compression to 6.1 percent swell when wetted. Four samples of clay soils exhibited unconfined compressive strengths of approximately 1,541 to 2,979 pounds per square foot (psf). Samples of site soils and bedrock selected for plasticity testing exhibited moderate to high plasticity with liquid limits ranging from 25 to 69 and plasticity indices ranging from 7 to 28. Laboratory test results are presented in the Exploration Results section of this report. Results of water-soluble sulfate testing indicate that ASTM Type I or II can be used throughout most areas of the site, with the notable exception of Boring No. R3, which Type V, or modified Type II portland cement should be specified for all project concrete on and below grade. As an alternative, ACI allows the use of cement that conforms to ASTM C150 Type II requirements, if it meets the Type V performance requirements (ASTM C452) of ASTM C150 Table 4. Foundation concrete should be designed for low sulfate exposure in most areas; concrete in the vicinity of Boring No. R3 should be designed for severe sulfate exposure in accordance with the provisions of the ACI Design Manual, Section 318, Chapter 4. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable 2 The boreholes were observed while drilling and after completion for the presence and level of groundwater. In addition, delayed water levels were also obtained in some borings. The water levels observed in the boreholes are noted on the attached boring logs, and are summarized below: Boring Number Depth to groundwater while drilling, ft. Depth to groundwater 5 days after drilling, ft. Elevation of groundwater 5 days after drilling, ft. B-01 Not encountered 11.6 5020.4 B-02 Not encountered 11.1 5017.9 B-03 10.5 10.2 5017.8 B-04 13.0 13.7 5011.3 B-05 9.0 13.0 5009.0 B-06 Not encountered 13.6 5015.4 B-07 Not encountered 20.4 5004.6 B-08 Not encountered 13.3 5008.7 B-09 Not encountered Not encountered Not encountered B-10 Not encountered 13.7 5005.3 B-11 Not encountered 22.8 5002.2 B-12 Not encountered Not encountered Not encountered B-13 Not encountered Not encountered Not encountered B-14 Not encountered 13.8 5009.2 B-15 17.0 12.8 5003.2 B-16 Not encountered 10.1 5003.9 B-17 Not encountered Not encountered Not encountered B-18 18.0 11.9 5004.1 R-01 11.0 8.7 4999.3 R-02 Not encountered 9.6 4997.4 R-03 Not encountered 6.6 5003.4 Groundwater level fluctuations occur due to seasonal variations, amount of rainfall, runoff, water levels in nearby water features, such as the Robert Benson Lake and other factors not evident at the time the borings were performed. Therefore, groundwater levels during construction or at other times in the life of the structures may be higher or lower than the levels indicated on the boring logs. The possibility of groundwater level fluctuations should be considered when developing the design and construction plans for the project. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Code Used Site Classification 2012/2015 International Building Code (IBC) 1 D 2 1. In general accordance with the 2012/2015 International Building Code, Table 1613.5.2. 2. The 2012/2015 International Building Code (IBC) requires a site soil profile determination extending a depth of 100 feet for seismic site classification. The current scope requested does not include the required 100 foot soil profile determination. The borings completed for this project extended to a maximum depth of about 25½ feet and this seismic site class definition considers that similar soil and bedrock conditions exist below the maximum depth of the subsurface exploration. Additional exploration to deeper depths could be performed to confirm the conditions below the current depth of exploration. Alternatively, a geophysical exploration could be utilized in order to attempt to justify a more favorable seismic site class. However, we believe a higher seismic site class for this site is unlikely. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Based on subsurface conditions encountered in the borings, the site appears suitable for the proposed construction from a geotechnical point of view provided certain precautions and design and construction recommendations described in this report are followed. We have identified several geotechnical conditions that could impact design, construction and performance of the proposed structures, pavements, and other site improvements. These included areas of moderate to highly expansive soils and to a lesser degree shallow bedrock. These conditions will require particular attention in Project Planning, design and during construction and discussed in greater detail in the following sections. Laboratory test results indicate that expansive soils and bedrock are present on this site and these conditions constitute a geologic hazard. This report provides recommendations to help mitigate the effects of soil shrinkage and expansion. However, even if these procedures are followed, some movement and cracking in the structures, pavements, and flatwork should be anticipated. The severity of cracking and other damage such as uneven floor slabs and flat work will probably increase if modification of the site results in excessive wetting or drying of the expansive clays and/or claystone bedrock. Eliminating the risk of movement and cosmetic distress is generally not feasible, but it may be possible to further reduce the risk of movement if significantly more expensive measures are used during construction. It is imperative the recommendations described in section Grading and Drainage and Ground Modification of this report be followed to reduce movement. As previously stated, bedrock was measured at depths ranging from about 9 to 20 feet below existing site grades. Although we do not anticipate bedrock significantly impacting the proposed construction bedrock could be encountered during on-site excavations for deep utility excavations. If foundation excavations penetrate bedrock, some heavy-duty equipment may be required to penetrate the bedrock. Additionally, foundations should not be partially constructed on bedrock or differential movement could occur. If bedrock is encountered at the bottom of a portion of a foundation excavation, such that a portion of the foundation is supported by bedrock and a portion of the foundation is supported by on-site soils, we recommend removing at least 3 feet of the bedrock material and replacing it with moisture-conditioned compacted fill. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable We recommend the proposed buildings be constructed on a post-tensioned slab foundation system provided the soils are over-excavated to a depth of at least 3 feet below the bottom of the slab and replaced with moisture conditioned, compacted engineered fill consisting of on-site soils. As a slightly higher risk alternative, a spread footing foundation system can be used. Design recommendations for foundations for the proposed structures and related structural elements are presented in the following paragraphs. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Prior to placing any fill, strip and remove existing vegetation and any other deleterious materials from the proposed construction areas. Stripped organic materials should be wasted from the site or used to re-vegetate landscaped areas or exposed slopes after completion of grading operations. Prior to the placement of fills, the site should be graded to create a relatively level surface to receive fill, and to provide for a relatively uniform thickness of fill beneath proposed structures. If fill is placed in areas of the site where existing slopes are steeper than 5:1 (horizontal:vertical), the area should be benched to reduce the potential for slippage between existing slopes and fills. Benches should be wide enough to accommodate compaction and earth moving equipment, and to allow placement of horizontal lifts of fill. The following presents recommendations for site demolition (if needed), excavation, ground modification, subgrade preparation and placement of engineered fills on the project. All earthwork on the project should be observed and evaluated by Terracon on a full-time basis. The evaluation of earthwork should include observation of over-excavation operations, testing of engineered fills, subgrade preparation, subgrade stabilization, and other geotechnical conditions exposed during the construction of the project. Demolition of the existing on-site building should include complete removal of all foundation systems, below-grade structural elements, pavements, and exterior flat work within the proposed construction area. This should include removal of any utilities to be abandoned along with any loose utility trench backfill or loose backfill found adjacent to existing foundations. All materials derived from the demolition of existing structures and pavements should be removed from the site. The types of foundation systems supporting the existing building are not known; however, we anticipate based on the building type that it is constructed on a shallow foundation. Consideration could be given to re-using the asphalt and concrete provided the materials are processed and uniformly blended with the on-site soils. Asphalt and/or concrete materials should be processed to a maximum size of 2-inches and blended at a ratio of 30 percent asphalt/concrete to 70 percent of on-site soils. As previously stated, we encountered expansive soils and bedrock on this site. In particular, swell testing indicated the upper 2 to 4 feet of lean clay soils on the northern portion of the site were Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable moderately to highly expansive. Without ground modification, we calculated potential ground heave as high as 2 to 3 inches. Therefore, we recommend ground modification below post- tensioned slab foundations, conventional slabs-on-grade (if spread footing foundations are selected), and pavements. Where less than 6 feet of fill is planned beneath proposed buildings, we recommend over-excavating the soils below post-tensioned slab foundations and conventional slabs-on-grade to a depth of at least 3 feet and replacing with properly moisture conditioned, compacted engineered fill consisting of on-site soils. For post-tensioned slab foundations, the over-excavation should be performed below the mass slab portion of the foundation and does not need to extend below the grade beams or other thickened sections. Expansive soils may also impact pavements on this site. We also recommend over- excavating to a depth of at least 18 inches below proposed pavements where site grading will not include fills to enhance performance and reduce risk for pavement distress caused by expansive soils. As a much lower risk alternative, we believe the subgrade soils below the proposed pavements could be chemically treated with fly ash. It is anticipated that excavations for the proposed construction can be accomplished with conventional earthmoving equipment. Excavation penetrating the bedrock (if any) or cemented soils may require the use of specialized heavy-duty equipment, together with ripping or jack-hammering drilling and blasting to advance the excavation and facilitate rock break-up and removal. Consideration should be given to obtaining a unit price for difficult excavation in the contract documents for the project. The soils to be excavated can vary significantly across the site as their classifications are based solely on the materials encountered in widely-spaced exploratory test borings. The contractor should verify that similar conditions exist throughout the proposed area of excavation. If different subsurface conditions are encountered at the time of construction, the actual conditions should be evaluated to determine any excavation modifications necessary to maintain safe conditions. Although evidence of fills was not observed during the site reconnaissance, such features could be encountered during construction. If unexpected fills or additional underground facilities not associated with the existing on-site building are encountered, such features should be removed and the excavation thoroughly cleaned prior to backfill placement and/or construction. Any over-excavation that extends below the bottom proposed buildings should extend laterally beyond all edges of the foundations at least 8 inches per foot of over-excavation depth below the foundation base elevation. The over-excavation should be backfilled to the foundation base elevation in accordance with the recommendations presented in this report. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Depending upon depth of excavation and seasonal conditions, surface water infiltration and/or groundwater may be encountered in excavations on the site. It is anticipated that pumping from sumps may be utilized to control water within excavations. The subgrade soil conditions should be evaluated during the excavation process and the stability of the soils determined at than the OSHA maximum values may have to be used. The individual contractor(s) should be made responsible for designing and constructing stable, temporary excavations as required to maintain stability of both the excavation sides and bottom. All excavations should be sloped or shored in the interest of safety following local, and federal regulations, including current OSHA excavation and trench safety standards. As a safety measure, it is recommended that all vehicles and soil piles be kept a minimum lateral distance from the crest of the slope equal to the slope height. The exposed slope face should be protected against the elements The top 8 inches of the exposed ground surface should be scarified, moisture conditioned, and recompacted to at least 95 percent of the maximum dry unit weight as determined by ASTM D698 before any new fill or foundation or pavement is placed. If pockets of soft, loose, or otherwise unsuitable materials are encountered at the bottom of the foundation excavations or at the base of the recommended over-excavations and it is inconvenient to lower the foundations, the proposed foundation elevations may be reestablished by over-excavating the unsuitable soils and backfilling with compacted engineered fill or lean concrete. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable After the bottom of the excavation has been compacted, engineered fill can be placed to bring the building pad and pavement subgrade to the desired grade. Engineered fill should be placed in accordance with the recommendations presented in subsequent sections of this report. The stability of the subgrade may be affected by precipitation, repetitive construction traffic or other factors. If unstable conditions develop, workability may be improved by scarifying and drying. Alternatively, over-excavation of wet zones and replacement with granular materials may be used, or crushed gravel and/or rock can be trac until a stable working surface is attained. Lightweight excavation equipment may also be used to reduce subgrade pumping. The on-site soils or approved granular and low plasticity cohesive imported materials may be used as fill material. The soil removed from this site that is free of organic or objectionable materials, as defined by a field technician who is qualified in soil material identification and compaction procedures, can be re-used as fill for the building pad and pavement subgrade. It should be noted that on-site soils will require reworking to adjust the moisture content to meet the compaction criteria. Imported soils (if required) should meet the following material property requirements: Gradation Percent finer by weight (ASTM C136) 100 70-100 No. 4 Sieve 50-100 No. 200 Sieve 15-50 Soil Properties Values Liquid Limit 35 (max.) Plastic Limit 6 (max.) Engineered fill should be placed and compacted in horizontal lifts, using equipment and procedures that will produce recommended moisture contents and densities throughout the lift. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Item Description Fill lift thickness 9 inches or less in loose thickness when heavy, self- propelled compaction equipment is used 4 to 6 inches in loose thickness when hand-guided equipment (i.e. jumping jack or plate compactor) is used Minimum compaction requirements Fills 8 feet: 95 percent of the maximum dry unit weight as determined by ASTM D698 Fills > 8 feet: 98 percent of the maximum dry unit weight as determined by ASTM D698 Moisture content cohesive soil (clay) -1 to +3 % of the optimum moisture content Moisture content cohesionless soil (sand) -3 to +3 % of the optimum moisture content 1. We recommend engineered fill be tested for moisture content and compaction during placement. Should the results of the in-place density tests indicate the specified moisture or compaction limits have not been met, the area represented by the test should be reworked and retested as required until the specified moisture and compaction requirements are achieved. 2. Specifically, moisture levels should be maintained low enough to allow for satisfactory compaction to be achieved without the fill material pumping when proofrolled. 3. Moisture conditioned clay materials should not be allowed to dry out. A loss of moisture within these materials could result in undesirable movement. All trench excavations should be made with sufficient working space to permit construction including backfill placement and compaction. All underground piping within or near the proposed structures should be designed with flexible couplings, so minor deviations in alignment do not result in breakage or distress. Utility knockouts in foundation walls should be oversized to accommodate differential movements. It is imperative that utility trenches be properly backfilled with relatively clean materials. If utility trenches are backfilled with relatively clean granular material, they should be capped with at least 18 inches of cohesive fill in non-pavement areas to reduce the infiltration and conveyance of surface water through the trench backfill. Utility trenches are a common source of water infiltration and migration. All utility trenches that penetrate beneath the buildings should be effectively sealed to restrict water intrusion and flow through the trenches that could migrate below the buildings. We recommend constructing an . ptimum Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable water content. The clay fill should be placed to completely surround the utility line and be compacted in accordance with recommendations in this report. It is strongly recommended that a representative of Terracon provide full-time observation and compaction testing of trench backfill within building and pavement areas. All grades must be adjusted to provide effective drainage away from the proposed buildings during construction and maintained throughout the life of the proposed project. Infiltration of water into foundation excavations must be prevented during construction. Landscape irrigation adjacent to foundations should be minimized or eliminated. Water permitted to pond near or adjacent to the perimeter of the structures (either during or post-construction) can result in significantly higher soil movements than those discussed in this report. As a result, any estimations of potential movement described in this report cannot be relied upon if positive drainage is not obtained and maintained, and water is allowed to infiltrate the fill and/or subgrade. Exposed ground (if any) should be sloped at a minimum of 10 percent grade for at least 10 feet beyond the perimeter of the proposed buildings, where possible. The use of swales, chases and/or area drains may be required to facilitate drainage in unpaved areas around the perimeter of the buildings. Backfill against foundations and exterior walls should be properly compacted and free of all construction debris to reduce the possibility of moisture infiltration. After construction of the proposed buildings and prior to project completion, we recommend verification of final grading be performed to document positive drainage, as described above, has been achieved. Flatwork and pavements will be subject to post-construction movement. Maximum grades practical should be used for paving and flatwork to prevent areas where water can pond. In addition, allowances in final grades should take into consideration post-construction movement of flatwork, particularly if such movement would be critical. Where paving or flatwork abuts the structures, care should be taken that joints are properly sealed and maintained to prevent the infiltration of surface water. Planters located adjacent to structures should preferably be self-contained. Sprinkler mains and spray heads should be located a minimum of 5 feet away from the building line(s). Low-volume, drip style landscaped irrigation should not be used near the building. Roof drains should discharge on to pavements or be extended away from the structures a minimum of 10 feet through the use of splash blocks or downspout extensions. A preferred alternative is to have the roof drains discharge by solid pipe to storm sewers or to a detention pond or other appropriate outfall. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Exterior slabs on-grade, exterior architectural features, and utilities founded on, or in backfill or the site soils will likely experience some movement due to the volume change of the material. Potential movement could be reduced by: Minimizing moisture increases in the backfill; Controlling moisture-density during placement of the backfill; Using designs which allow vertical movement between the exterior features and adjoining structural elements; and Placing control joints on relatively close centers. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Based on the subsurface conditions encountered at this site, we believe post-tensioned slabs can be used for support of the structures provided some foundation movement can be tolerated and: The post-tensioned slab foundations are properly designed and constructed. Approved materials supporting the foundation are properly placed and compacted. Proper surface drainage is maintained throughout the life of the structures. Prudent landscaping measures are used. Expansive soils and bedrock are present on this site. Discussion regarding ground modification below proposed foundations are presented in the Ground Modification section of this report. In our opinion, total foundation movements on the order of about 1 inch after ground modification should be expected. Provided foundations are properly designed, foundation movements could result in periodic, and possibly seasonal, cosmetic distress to drywall, window frames, door frames and other features. We would anticipate that the frequency of distress and amount of movement would generally diminish with time provided proper drainage is established and/or maintained. Based on the subsurface conditions, post-tensioned slabs should be designed using criteria outlined by the Post-Tensioning Institute1 based on the following: Post-tensioned Slab Design Parameters PTI, Third Edition 2006 IBC/IRC Edge Moisture Variation Distance, em (feet) Center Lift Condition 9 Edge Lift Condition 5 Differential Soil Movement, ym (inches) Center Lift Condition 2.0 Edge Lift Condition 1.5 Description Recommendations Over excavation depth 3 feet Lateral over excavation extent At least 5 feet beyond the building footprints Maximum allowable bearing pressure (psf) 2,000 1 (2004, Third Edition), Design (and Construction) of Post-Tensioned Slabs-on-Ground, Post-Tensioning Institute. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Description Recommendations Slab-subgrade friction coefficient, µ On polyethylene sheeting 0.75 On cohesionless soils 1.00 On cohesive soils 2.00 The maximum allowable net bearing pressure may be increased by 1/3 for transient wind or seismic loading. It should be noted that ym is the estimated vertical movement at the edges of a uniformly loaded slab. These are theoretical values that are used in the design of post-tensioned slabs and do not represent the movements that would be expected from the actual loading conditions. As previously discussed, the use of post-tensioned slabs assumes that some potential movement is considered acceptable. Post-tensioned slabs, thickened or turndown edges and/or interior beams should be designed and constructed in accordance with the requirements of the PTI and the American Concrete Institute (ACI). As previously discussed, foundations should be protected from frost heave by burial or using insulation. If traditional post-tensioned slab foundations are selected, exterior slab edges should be placed a minimum of 30 inches below finished grade for frost protection. Finished grade is the lowest adjacent grade for perimeter beams. If portions of the building floor slab will be unheated, such as patios and entryways, consideration should be given to structurally separating these areas of the slab from the remaining interior portion of the slab. Exterior slab areas may be cantilevered portions of the slab which are subject to uplift from frost heave and swelling of the expansive soils, sometimes beyond those used for design, due to over watering of adjacent to landscaped areas. Such movement in the exterior slabs can result in change in slab grade to the point where negative grade results and water ponds adjacent to the interior areas of the slab. Repairs of such conditions are difficult and costly, particularly if the floor slabs are post-tensioned slabs. Exterior slabs in unheated areas are subject to frost heave beneath the slab. Therefore, in design of the exterior slabs, potential movement from frost heave should be considered in the design. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable It should be noted that the presences of 1 to 2-foot steps within long spans of post-tensioned slabs could create a situation where the slabs at different elevations perform independently of one another unless the steps are properly reinforced and designed to tie the slabs together to act as one rigid structure. We strongly recommend that joints be designed within the full height of the structure of the building over each step in order to help the structure be capable of withstanding movements on the order of 1 inch. The estimated movement should also be considered as the potential amount of tilting of the structure, which could be caused by non-uniform, significant wetting of the subsurface materials below the post-tensioned slab, resulting in potential movement. Failure to maintain soil water content below the slab and to maintain proper drainage around the structure will nullify the movement estimates provided above. As a slightly higher risk alternative to a post-tensioned slab foundation, a spread footing foundation system can be used for support of the proposed buildings. Description Values Bearing material Properly prepared on-site soil (lean clay), or new, properly placed engineered fill (granular soil). Maximum allowable bearing pressure1 2,500 psf Lateral earth pressure coefficients2 Lean clay: Active, Ka = 0.33 Passive, Kp = 3.0 At-rest, Ko = 0.50 Granular soil: Active, Ka = 0.27 Passive, Kp = 3.69 At-rest, Ko = 0.43 Sliding coefficients2 Lean clay: µ = 0.46 Granular soil: µ = 0.56 Moist soil unit weight Lean clay: = 105 pcf Granular soil: = 130 pcf Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Description Values Minimum embedment depth below finished grade 3 30 inches Estimated total movement 4 About 1 inch Estimated differential movement 4 About ½ to ¾ of total movement 1. The recommended maximum allowable bearing pressure assumes any unsuitable fill or soft soils, if encountered, will be over-excavated and replaced with properly compacted engineered fill. The design bearing pressure applies to a dead load plus design live load condition. The design bearing pressure may be increased by one-third when considering total loads that include wind or seismic conditions. 2. The lateral earth pressure coefficients and sliding coefficients are ultimate values and do not include a factor of safety. The foundation designer should include the appropriate factors of safety. 3. For frost protection and to reduce the effects of seasonal moisture variations in the subgrade soils. The minimum embedment depth is for perimeter footings beneath unheated areas and is relative to lowest adjacent finished grade, typically exterior grade. 4. The estimated movements presented above are based on the assumption that the maximum footing size is 6 feet for column footings and 3 feet for continuous footings. Footings should be proportioned to reduce differential foundation movement. As discussed, total movement resulting from the assumed structural loads is estimated to be on the order of about 1 inch. Additional foundation movements could occur if the Ground Modification section of this report is not followed or water from any source infiltrates the foundation soils; therefore, proper drainage should be provided in the final design and during construction and throughout the life of the structure. Failure to maintain the proper drainage as recommended in the Grading and Drainage section of this report will nullify the movement estimates provided above. Spread footing construction should only be considered if the estimated foundation movement can be tolerated. Subgrade soils beneath footings should be moisture conditioned and compacted as described in the Site Preparation section of this report. The moisture content and compaction of subgrade soils should be maintained until foundation construction. Footings and foundation walls should be reinforced as necessary to reduce the potential for distress caused by differential foundation movement. Unstable surfaces (if encountered) will need to be stabilized prior to backfilling excavations and/or constructing the building foundation, floor slab and/or project pavements. The use of angular rock, suitable means of stabilizing the subgrade. The use of geogrid materials in conjunction with gravel could also be considered and could be more cost effective. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Unstable subgrade conditions should be observed by Terracon to assess the subgrade and provide suitable alternatives for stabilization. Stabilized areas should be proof-rolled prior to continuing construction to assess the stability of the subgrade. Foundation excavations should be observed by Terracon. If the soil conditions encountered differ significantly from those presented in this report, supplemental recommendations will be required. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable If a post-tensioned slab foundation is used to support the buildings, the foundation slab will also act as a floor slab. If a spread footing foundation system is used, a slab-on-grade may be utilized for the interior floor system for the proposed buildings, provided the native clay soils are over- excavated to a depth of at least 3 feet below the floor slab, moisture conditioned and recompacted. Where site grading will result in at least 6 feet of fill below the proposed building, over-excavation will not be necessary below that particular building. If the estimated movement cannot be tolerated, a structurally-supported floor system, supported independent of the subgrade materials, is recommended. Subgrade soils beneath interior and exterior slabs and at the base of the over-excavation should be scarified to a depth of at least 8 inches, moisture conditioned and compacted. The moisture content and compaction of subgrade soils should be maintained until slab construction. Even when bearing on properly prepared soils, movement of the slab-on-grade floor system is possible should the subgrade soils undergo an increase in moisture content. We estimate movement of about 1 inch is possible. If the owner cannot accept the risk of slab movement, a structural floor should be used. If conventional slab-on-grade is utilized, the subgrade soils should be over-excavated and/or prepared as presented in the Site Preparation section of this report. For structural design of concrete slabs-on-grade subjected to point loadings, a modulus of subgrade reaction of 100 pounds per cubic inch (pci) may be used for floors supported on re- compacted existing soils at the site. Additional floor slab design and construction recommendations are as follows: Positive separations and/or isolation joints should be provided between slabs and all foundations, columns, or utility lines to allow independent movement. Control joints should be saw-cut in slabs in accordance with ACI Design Manual, Section 302.1R-37 8.3.12 (tooled control joints are not recommended) to control the location and extent of cracking. Interior utility trench backfill placed beneath slabs should be compacted in accordance with the recommendations presented in the Site Preparation section of this report. Floor slabs should not be constructed on frozen subgrade. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable A minimum 1½-inch void space should be constructed above or below non-bearing partition walls placed on the floor slab. Special framing details should be provided at doorjambs and frames within partition walls to avoid potential distortion. Partition walls should be isolated from suspended ceilings. The use of a vapor retarder should be considered beneath concrete slabs that will be covered with wood, tile, carpet or other moisture sensitive or impervious floor coverings, or when the slab will support equipment sensitive to moisture. When conditions warrant the use of a vapor retarder, the slab designer and slab contractor should refer to ACI 302 for procedures and cautions regarding the use and placement of a vapor retarder. Other design and construction considerations, as outlined in the ACI Design Manual, Section 302.1R are recommended. Movements of slabs-on-grade using the recommendations discussed in previous sections of this report will likely be reduced and tend to be more uniform. The estimates discussed above assume that the other recommendations in this report are followed. Additional movement could occur should the subsurface soils become wetted to significant depths, which could result in potential excessive movement causing uneven floor slabs and severe cracking. This could be due to over watering of landscaping, poor drainage, improperly functioning drain systems, and/or broken utility lines. Therefore, it is imperative that the recommendations presented in this report be followed. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable BELOW-GRADE STRUCTURES Below-grade structures or reinforced concrete walls with unbalanced backfill levels on opposite sides should be designed for earth pressures at least equal to those indicated in the following table. Earth pressures will be influenced by structural design of the walls, conditions of wall restraint, methods of construction and/or compaction and the strength of the materials being restrained. Two wall restraint conditions are shown. Active earth pressure is commonly used for design of free-standing cantilever retaining walls and assumes wall movement. The "at-rest" condition assumes no wall movement. The recommended design lateral earth pressures do not include a factor of safety and do not provide for possible hydrostatic pressure on the walls. Earth Pressure Coefficients Earth Pressure Conditions Coefficient for Backfill Type Equivalent Fluid Density (pcf) Surcharge Pressure, p1 (psf) Earth Pressure, p2 (psf) Active (Ka) Lean Clay - 0.33 Granular Fill 0.27 40 32 (0.33)S (0.27)S (40)H (32)H At-Rest (Ko) Lean Clay - 0.50 Granular Fill 0.43 60 52 (0.50)S (0.43)S (60)H (52)H Passive (Kp) Lean Clay 3.0 Granular Fill 3.69 360 443 --- --- --- --- Applicable conditions to the above include: For active earth pressure, wall must rotate about base, with top lateral movements of about 0.002 H to 0.004 H, where H is wall height For passive earth pressure to develop, wall must move horizontally to mobilize resistance Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Uniform surcharge, where S is surcharge pressure In-situ soil backfill weight a maximum of 120 pcf Horizontal backfill, compacted between 95 and 98 percent of standard Proctor maximum dry density Loading from heavy compaction equipment not included No hydrostatic pressures acting on wall No dynamic loading No safety factor included Ignore passive pressure in frost zone Backfill placed against structures should consist of granular soils or low plasticity cohesive soils. For the granular values to be valid, the granular backfill must extend out and up from the base of the wall at an angle of at least 45 and 60 degrees from vertical for the active and passive cases, respectively. To calculate the resistance to sliding, a value of 0.32 should be used as the ultimate coefficient of friction between the footing and the underlying soil. A perforated rigid plastic or metal drain line installed behind the base of walls that extend below adjacent grade is recommended to prevent hydrostatic loading on the walls. The invert of a drain line around a below-grade building area or exterior retaining wall should be placed near foundation bearing level. The drain line should be sloped to provide positive gravity drainage or to a sump pit and pump. The drain line should be surrounded by clean, free-draining granular material having less than 5 percent passing the No. 200 sieve. The free-draining aggregate should be encapsulated in a filter fabric. The granular fill should extend to within 2 feet of final grade, where it should be capped with compacted cohesive fill to reduce infiltration of surface water into the drain system. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable As an alternative to free-draining granular fill, a pre-fabricated drainage structure may be used. A pre-fabricated drainage structure is a plastic drainage core or mesh which is covered with filter fabric to prevent soil intrusion, and is fastened to the wall prior to placing backfill. To control hydrostatic pressure behind the wall we recommend that a drain be installed at the foundation wall with a collection pipe leading to a reliable discharge. If this is not possible, then combined hydrostatic and lateral earth pressures should be calculated for lean clay backfill using an equivalent fluid weighing 90 and 100 pcf for active and at-rest conditions, respectively. For granular backfill, an equivalent fluid weighing 85 and 90 pcf should be used for active and at-rest, respectively. These pressures do not include the influence of surcharge, equipment or floor loading, which should be added. Heavy equipment should not operate within a distance closer than the exposed height of retaining walls to prevent lateral pressures more than those provided. We understand a swimming pool is conceptually planned near the clubhouse in the southern portion of the project site. The construction and performance of the pool may be affected by the presence of groundwater encountered at depths ranging from approximately 10 to 14 feet below existing site grades near the central portion of the site. Construction and/or permanent dewatering may be required for swimming pool construction and service. Excavation of the pool area by conventional rubber-tired equipment may encounter soft or very loose soils and/or severe pumping when nearing groundwater level. It may be necessary to excavate the deep portion of the pool with a backhoe or power shovel. If the excavation extends into the groundwater, a one-piece fiberglass or similar pool should be installed. As a precaution, pressure relief valves should be placed in the deep end of any pool constructed to prevent flotation should groundwater rise when the pool is empty. We recommend coordination with a qualified swimming pool specialty contractor to discuss alternatives to address the effects of shallow groundwater on the proposed swimming pool. A drainage system should be provided around and beneath the pool. The drain should consist of a minimum 6-inch layer of clean gravel (minimum 3/4-inch size) beneath and along the sides of the pool. The top of the drain layer should be sealed with 18 inches of relatively impermeable soil at the surface. The gravel layer beneath the pool should be sloped so that it will drain into tiles or perforated drainpipe. The layout of the perforated pipe should include at least one pipe running down the center of the pool lengthwise. Cross-connecting pipes, spanning with the pool, should be placed at 6-foot centers. The cross-connecting pipes should be joined to the center pipe with enter pipes should be sloped to a positive gravity outlet or sloped to a sump located in the equipment room, permitting pump discharge. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable The bottom of the excavation beneath the gravel layer and the pipe should be lined with an impervious membrane (polyethylene film or equal) to reduce potential moisture fluctuations in the subgrade soils. Pressure relief valves should be provided in the base of the pool to prevent excessive uplift pressures from developing in the event of drain system failure. The soils that will support deck slabs around the pool could expand with increasing moisture content. To reduce possible damage that could be caused by expansive soils, we recommend: Deck slabs be supported on fill with no, or very low, expansion potential; Strict moisture-density control during placement of subgrade fill; Placement of effective control joints on relatively close centers and isolation joints between slabs and other structural elements; Provision for adequate drainage in areas adjoining the slabs; and Use of designs which allow vertical movement between the deck slabs and adjoining structural elements. Fill, backfill, and surface drainage in the pool area should be place in accordance with the recommendations presented in the Site Preparation section of this report. Grading should be provided for diversion of deck surface runoff away from the pool area. In no case should water be allowed to pond around the slab perimeter. We assume an elevator pit will be included in the interior of the building(s). The elevator pit will likely consist of reinforced concrete walls with a concrete base slab. Based on our experience with this type of structure, we anticipate the base slabs will be about 5 feet below the level of the finished floor slab. Subsurface conditions in elevator pit excavations are generally anticipated to consist of native clays. Groundwater was encountered at depths of about 6.6 to 20.4 feet below existing site grades at the time of our field exploration. However, groundwater levels can and should be expected to fluctuate over time. We also understand portions of the site where the shallowest groundwater was measured are planned for significant fills and raising of site grades. Depending upon final site grades and elevator pit elevations, groundwater could impact the performance of the pit base slab. If the pit slab is constructed at or within about 4 feet of the level of groundwater, the pit/slab should be designed and constructed to resist hydrostatic pressures and uplift due to the effects of buoyancy or it should be protected by an underdrain system for permanent - Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable not used. Terracon should evaluate the groundwater level within each elevator pit area prior to or during construction. The elevator pit walls should be designed for the lateral earth pressures imposed by the soil backfill. Earth pressures will primarily be influenced by structural design of the walls, conditions of wall restraint and type, compaction and drainage of the backfill. For purposes of design, we have assumed approximately 5 feet of fill will be retained by the pit walls and backfill will consist of the on-site lean clays. If taller walls are planned, or if different type of backfill is used, we should be contacted to review our data and confirm or modify the design criteria presented below. Active earth pressure is commonly used for design of walls (such as free-standing cantilever retaining walls) and assumes some wall rotation and deflection. For walls that can deflect and rotate about the base, with top lateral movements of about ¼ to ½ percent or more of the wall assumes deflection and thus cracking of walls could occur. For rigid walls where negligible or very little rotation and deflection will occur, "at-rest" lateral earth pressures should be used in the design. Reinforced concrete pit walls should be designed for lateral earth pressures and/or combined hydrostatic and lateral earth pressures at least equal to those indicated in the following table. Earth Pressure Conditions Backfill Soil Type Equivalent Fluid Density (above water, pcf) Equivalent Fluid Density (below water, pcf) Active (Ka) On-site lean clay 40 80 At-Rest (Ko) On-site lean clay 60 90 The lateral earth pressures presented above do not include a factor of safety. As such, appropriate factors of safety should be applied to these values. Furthermore, the lateral earth pressures do not include the influence of surcharge, equipment or floor loading, which should be added. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable On most project sites, the site grading is accomplished relatively early in the construction phase. Fills are typically placed and compacted in a uniform manner. However as construction proceeds, the subgrade may be disturbed due to utility excavations, construction traffic, desiccation, or rainfall/snow melt. As a result, the pavement subgrade may not be suitable for pavement construction and corrective action will be required. The subgrade should be carefully evaluated at the time of pavement construction for signs of disturbance or instability. We recommend the pavement subgrade be thoroughly proofrolled with a loaded tandem-axle dump truck prior to final grading and paving. All pavement areas should be moisture conditioned and properly compacted to the recommendations in this report immediately prior to paving. As stated in the Ground Modification section of this report, due to the moderate to highly expansive soils encountered on this site the top 18 inches of on-site soil below pavements should be over-excavated, moisture conditioning and recompacted. Where site grading will result in at least 18 inches of fill below pavements, over-excavation will not be necessary. Additionally, the top 8 inches of the subgrade soils at the bottom of the over-excavation should be scarified, moisture-conditioned and recompacted as recommended in the Site Preparation section of this report. As a much lower risk alternative, we believe the subgrade soils below the proposed pavements could be chemically treated with fly ash. Design of new privately-maintained pavements for the project has been based on the procedures described by the National Asphalt Pavement Associations (NAPA) and the American Concrete Institute (ACI). We assumed the following design parameters for NAPA flexible pavement thickness design: Automobile Parking Areas Class I - Parking stalls and parking lots for cars and pick-up trucks, with Equivalent Single Axle Load (ESAL) up to 7,000 over 20 years Main Traffic Corridors Class III Collector Streets, with Equivalent Single Axle Load (ESAL) up to 73,000 over 20 years (including trash trucks) Subgrade Soil Characteristics USCS Classification CL, classified by NAPA as poor Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable We assumed the following design parameters for ACI rigid pavement thickness design based upon the average daily truck traffic (ADTT): Automobile Parking Areas ACI Category A: Automobile parking with an ADTT of 1 over 20 years Main Traffic Corridors ACI Category B: Bus parking areas and service lanes with an ADTT of up to 50 over 20 years Subgrade Soil Characteristics USCS Classification CL Concrete modulus of rupture value of 600 psi We should be contacted to confirm and/or modify the recommendations contained herein if actual traffic volumes differ from the assumed values shown above. Recommended alternatives for flexible and rigid pavements are summarized for each traffic area as follows: Traffic Area Alternative Recommended Pavement Thicknesses (Inches) Asphaltic Concrete Surface Aggregate Base Course Portland Cement Concrete Total Automobile Parking (NAPA Class I and ACI Category A) A 3½ 6 - 9½ B - - 5 5 Service Lanes (NAPA Class III and ACI Category B) A 6 8 - 14 B - - 6½ 6½ Aggregate base course (if used on the site) should consist of a blend of sand and gravel which meets strict specifications for quality and gradation. Use of materials meeting Colorado Department of Transportation (CDOT) Class 5 or 6 specifications is recommended for aggregate base course. Aggregate base course should be placed in lifts not exceeding 6 inches and compacted to a minimum of 95 percent of the maximum dry unit weight as determined by ASTM D698. Asphaltic concrete should be composed of a mixture of aggregate, filler and additives (if required) and approved bituminous material. The asphalt concrete should conform to approved mix designs stating the Superpave properties, optimum asphalt content, job mix formula and recommended mixing and placing temperatures. Aggregate used in asphalt concrete should meet particular gradations. Material meeting CDOT Grading S or SX specifications or equivalent is recommended for asphalt concrete. Mix designs should be submitted prior to construction to Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable verify their adequacy. Asphalt material should be placed in maximum 3-inch lifts and compacted within a range of 92 to 96 percent of the theoretical maximum (Rice) density (ASTM D2041). Where rigid pavements are used, the concrete should be produced from an approved mix design with the following minimum properties: Properties Value Compressive strength 4,000 psi Cement type Type I or II portland cement Entrained air content (%) 5 to 8 Concrete aggregate ASTM C33 and CDOT section 703 Concrete should be deposited by truck mixers or agitators and placed a maximum of 90 minutes from the time the water is added to the mix. Longitudinal and transverse joints should be provided as needed in concrete pavements for expansion/contraction and isolation per ACI 325. The location and extent of joints should be based upon the final pavement geometry. For areas subject to concentrated and repetitive loading conditions (if any) such as dumpster pads, truck delivery docks and ingress/egress aprons, we recommend using a portland cement concrete pavement with a thickness of at least 6 inches underlain by at least 4 inches of granular base. Prior to placement of the granular base, the areas should be thoroughly proofrolled. For dumpster pads, the concrete pavement area should be large enough to support the container and tipping axle of the refuse truck. Pavement performance is affected by its surroundings. In addition to providing preventive maintenance, the civil engineer should consider the following recommendations in the design and layout of pavements: Site grades should slope a minimum of 2 percent away from the pavements; The subgrade and the pavement surface have a minimum 2 percent slope to promote proper surface drainage; Consider appropriate edge drainage and pavement under drain systems; Install pavement drainage surrounding areas anticipated for frequent wetting; Install joint sealant and seal cracks immediately; Seal all landscaped areas in, or adjacent to pavements to reduce moisture migration to subgrade soils; and Placing compacted, low permeability backfill against the exterior side of curb and gutter. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Openings in pavement, such as landscape islands, are sources for water infiltration into surrounding pavements. Water collects in the islands and migrates into the surrounding subgrade soils thereby degrading support of the pavement. This is especially applicable for islands with raised concrete curbs, irrigated foliage, and low permeability near-surface soils. The civil design for the pavements with these conditions should include features to restrict or to collect and discharge excess water from the islands. Examples of features are edge drains connected to the storm water collection system or other suitable outlet and impermeable barriers preventing lateral migration of water such as a cutoff wall installed to a depth below the pavement structure. Preventative maintenance should be planned and provided for an ongoing pavement management program in order to enhance future pavement performance. Preventive maintenance consists of both localized maintenance (e.g. crack and joint sealing and patching) and global maintenance (e.g. surface sealing). Preventative maintenance is usually the first priority when implementing a planned pavement maintenance program and provides the highest return on investment for pavements. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Our work is conducted with the understanding of the project as described in the proposal, and will incorporate collaboration with the design team prior to completing our services. Terracon has requested verification of all stated assumptions. Revision of our understanding to reflect actual conditions important to our work will be based on these verifications and will be reflected in the final report. The design team should collaborate with Terracon to confirm these assumptions. The design team should also collaborate with Terracon to prepare the final design plans and specifications. This facilitates the incorporation of our opinions related to implementation of our geotechnical recommendations. Our analysis and opinions are based upon our understanding of the geotechnical conditions in the area, the data obtained from the site exploration performed and from our understanding of the project. Variations will occur between exploration point locations, across the site, or due to the modifying effects of construction or weather. The nature and extent of such variations may not become evident until during or after construction. So, Terracon should be retained to provide observation and testing services during grading, excavation, foundation construction and other earth-related construction phases of the project. If variations appear, we can provide further evaluation and supplemental recommendations. If variations are noted in the absence of our observation and testing services on-site, we should be immediately notified so that we can provide evaluation and supplemental recommendations. Our scope of services does not include either specifically or by implication any environmental or biological (e.g., mold, fungi, bacteria) assessment of the site or identification or prevention of pollutants, hazardous materials or conditions. If the owner is concerned about the potential for such contamination or pollution, other studies should be undertaken. Our services and any correspondence are intended for the exclusive use of our client for specific application to the project discussed and are accomplished in accordance with generally accepted geotechnical engineering practices. No warranties, either express or implied, are intended or made. Site characteristics as provided are for design purposes and not to estimate excavation cost. Any use of our report in that regard is done at the sole risk of the excavating cost estimator as there may be variations on the site that are not apparent in the data that could significantly impact excavation cost. Any parties charged with estimating excavation costs should seek their own site characterization for that specific purposes to obtain the specific level of detail necessary for costing. Site safety, and cost estimating including, excavation support, and dewatering requirements/design are the responsibility of others. In the event that changes in the nature, design, or location of the project are planned, our conclusions and recommendations shall not be considered valid unless we review the changes and either verify or modify our conclusions in writing. TOPOGRAPHIC MAP IMAGE COURTESY OF THE U.S. GEOLOGICAL SURVEY QUADRANGLES INCLUDE: FORT COLLINS, CO (1984) and LOVELAND, CO (1984). SITE LOCATION MAP Pedcor Fort Collins North College Avenue and Trilby Road Fort Collins, CO 20165101 DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES MGH EDB EDB EDB 11/28/2016 SITE 20165101 EXPLORATION PLAN AERIAL PHOTOGRAPHY PROVIDED BY MICROSOFT BING MAPS Pedcor Fort Collins North College Avenue and Trilby Road Fort Collins, CO DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES MGH EDB EDB EDB 11/28/2016 AS SHOWN 20165101 EXPLORATION PLAN (BUILDING PLAN) AERIAL PHOTOGRAPHY PROVIDED BY MICROSOFT BING MAPS Pedcor Fort Collins North College Avenue and Trilby Road Fort Collins, CO DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES MGH EDB EDB EDB 11/28/2016 AS SHOWN Building Boring Pavement Boring Retention Pond Boring P-1 P-2 P-3 P-4 P-5 P-6 P-7 B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 B-15 B-16 B-17 B-18 R-1 R-2 R-3 13-21-10 N=31 8-9 6-12-17 N=29 20-37-50 N=87 20-50/6" N=70/12" 0.6 10.0 11.0 20.0 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY (CL), light brown to brown, stiff to hard WEATHERED BEDROCK - CLAYSTONE, brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, brown to gray, very hard Boring Terminated at 20 Feet 10 11 17 12 12 42-18-24 5031.5 5022 5021 5012 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49134° Longitude: -105.07682° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-01 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of 8-12 3-3-5 N=8 4-5 8-12-20 N=32 15-21-32 N=53 0.6 14.0 15.0 20.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND (CL), light brown to brown with white, medium stiff to very stiff WEATHERED BEDROCK - CLAYSTONE, brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, brown to orange brown, medium firm to hard Boring Terminated at 20.5 Feet UC 1737 14.6 11 18 23 16 16 113 106 40-16-24 8028.5 8015 8014 8008.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49131° Longitude: -105.07633° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-02 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. 3-4-3 N=7 4-7 4-4-6 N=10 7-9 13-19-29 N=48 24-36-45 N=81 0.6 7.0 18.5 25.5 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY (CL), brown, stiff LEAN CLAY WITH SAND, light brown, stiff SEDIMENTARY BEDROCK - CLAYSTONE, orange brown to gray, medium hard to very hard Boring Terminated at 25.5 Feet 15 13 22 22 13 10 102 104 37-18-19 5027.5 5021 5009.5 5002.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49143° Longitude: -105.07568° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. B-03 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. 12-15 5-5-6 N=11 6-8 7-12-15 N=27 12-22-26 N=48 0.6 3.0 14.0 16.0 20.5 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY, brown, very stiff LEAN CLAY WITH SAND, light brown, stiff WEATHERED BEDROCK - CLAYSTONE, brown to orange brown, weathered to firm SEDIMENTARY BEDROCK - CLAYSTONE, brown to gray, medium hard Boring Terminated at 20.5 Feet UC 1541 11.9 7 15 24 19 16 109 103 5024.5 5022 5011 5009 5004.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49134° Longitude: -105.07499° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. B-04 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. 5-7 3-3-4 N=7 4-4-7 N=11 12-27 17-26-32 N=58 0.6 3.0 11.0 15.0 20.5 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY, brown, stiff LEAN CLAY WITH SAND, light brown to orange brown, stiff WEATHERED BEDROCK - CLAYSTONE, dark brown to orange brown, weathered to firm SEDIMENTARY BEDROCK - CLAYSTONE, dark brown to gray, hard Boring Terminated at 20.5 Feet 17 18 20 18 16 107 108 5021.5 5019 5011 5007 5001.5 +1.1/1,000 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49132° Longitude: -105.07447° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. B-05 CLIENT: Pedcor Investments, LLC 12-25 10-12-12 N=24 20-30 22-50/6" N=72/12" 26-50/5" N=76/11" 0.6 8.0 9.0 10.0 15.0 19.9 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY (CL), light brown to brown with white, very stiff LEAN CLAY WITH SAND, brown, medium stiff to stiff WEATHERED BEDROCK - CLAYSTONE, dark brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, orange brown to gray, hard SEDIMENTARY BEDROCK - SANDSTONE/CLAYSTONE, gray to red brown, very hard Boring Terminated at 19.9 Feet 9 9 17 15 13 109 112 44-17-27 5028.5 5021 5020 5019 5014 5009 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49096° Longitude: -105.07665° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: 9-11-10 N=21 11-17 3-3-5 N=8 7-20 11-27-31 N=58 18-32-23 N=55 0.6 15.0 16.0 24.5 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY (CL), light brown to yellow brown, stiff to very stiff WEATHERED BEDROCK - CLAYSTONE, brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, orange brown to gray, hard Boring Terminated at 24.5 Feet 9 10 22 21 18 17 109 104 49-19-30 5024.5 5010 5009 5000.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49087° Longitude: -105.07619° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. B-07 CLIENT: Pedcor Investments, LLC Carmel, Indiana 6-9-9 N=18 11-15 12-36 7-20-24 N=44 10-17-23 N=40 0.6 10.0 14.5 20.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND (CL), orange brown to light brown, very stiff WEATHERED BEDROCK - CLAYSTONE, brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, orange brown to gray, medium hard Boring Terminated at 20.5 Feet 9 10 19 19 18 101 101 37-19-18 5021.5 5012 5007.5 5001.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49092° Longitude: -105.07555° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. B-08 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/7/2016 7-8 4-3-3 N=6 8-7 10-20-23 N=43 14-33-50 N=83 0.6 14.0 14.5 20.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, orange brown to light brown, medium stiff to stiff WEATHERED BEDROCK - CLAYSTONE (CH), brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, gray, medium hard to very hard Boring Terminated at 20.5 Feet 11 17 16 5 18 0 69-31-38 5017.5 5004 5003.5 4997.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49075° Longitude: -105.07492° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. B-09 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins 4-5-7 N=12 8-13 3-3-5 N=8 4-4-7 N=11 6-10-16 N=26 28-41-50 N=91 0.6 8.0 20.0 22.0 25.5 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY (CL), orange brown, stiff LEAN CLAY WITH SAND, orange brown to light brown, stiff WEATHERED BEDROCK - CLAYSTONE, brown to orange brown, weathered to firm SEDIMENTARY BEDROCK - CLAYSTONE, gray to yellow brown, very hard Boring Terminated at 25.5 Feet 10 11 18 22 21 16 112 38-19-19 5018.5 5011 4999 4997 4993.5 +1.1/500 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49076° Longitude: -105.07432° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 7-10-8 N=18 4-5-5 N=10 4-4 4-4-5 N=9 12-20-21 N=41 30-50/4" N=80/10" 0.6 6.0 19.0 20.0 24.8 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown, stiff to very stiff SANDY LEAN CLAY (CL), light brown to orange brown, medium stiff to stiff WEATHERED BEDROCK - CLAYSTONE, dark brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, dark brown to gray, medium hard to very hard Boring Terminated at 24.8 Feet 9 11 16 23 18 15 103 28-14-14 5024.5 5019 5006 5005 5000 -0.9/1,000 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49026° Longitude: -105.07683° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 6-10-12 N=22 4-5-7 N=12 3-3 3-4-8 N=12 12-18-28 N=46 0.6 15.0 17.0 20.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND (CL), light brown with white to orange brown, medium stiff to very stiff WEATHERED BEDROCK - CLAYSTONE, brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, orange brown to gray, medium hard Boring Terminated at 20.5 Feet 10 13 19 24 20 91 37-16-21 5020.5 5006 5004 5000.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49047° Longitude: -105.07616° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-12 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 6-8-8 N=16 8-8 2-2-3 N=5 20-30 15-50/6" N=65/12" 0.6 6.0 14.0 14.5 20.0 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY (CL), light brown with white, stiff to very stiff LEAN CLAY WITH SAND, light brown to orange brown, medium stiff WEATHERED BEDROCK - CLAYSTONE, brbown to gray, weathered SEDIMENTARY BEDROCK - CLAYSTONE, orange brown to gray, hard Boring Terminated at 20 Feet 11 8 24 15 16 118 112 37-18-19 5014.5 5009 5001 5000.5 4995 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49053° Longitude: -105.07547° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-13 CLIENT: Pedcor Investments, LLC 5-7-5 N=12 4-4-6 N=10 5-7 4-6 9-15-20 N=35 26-50/6" N=76/12" 0.6 7.0 19.0 20.0 25.0 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown, stiff SANDY LEAN CLAY (CL), light brown to orange brown, stiff WEATHERED BEDROCK - CLAYSTONE, gray to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, gray, medium hard to hard Boring Terminated at 25 Feet 10 13 20 22 20 15 119 119 104 31-18-13 5022.5 5016 5004 5003 4998 0.0/1,000 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.48989° Longitude: -105.07678° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 5-7-7 N=14 5-7 2-2-3 N=5 5-5 8-17-25 N=42 15-25-30 N=55 0.6 7.0 20.0 25.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown with white, stiff to very stiff SANDY LEAN CLAY (CL), light brown to orange brown, medium stiff to stiff SEDIMENTARY BEDROCK - CLAYSTONE, gray, medium hard to hard Boring Terminated at 25.5 Feet 12 14 22 23 23 22 107 106 39-17-22 5015.5 5009 4996 4990.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.4899° Longitude: -105.07625° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem auger Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-15 CLIENT: Pedcor Investments, LLC Carmel, Indiana 10-15 4-4-5 N=9 5-8 5-5-10 N=15 8-12-25 N=37 19-25-36 N=61 0.6 7.0 15.5 16.0 25.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown to brown, stiff to very stiff SANDY LEAN CLAY (CL), light brown, stiff WEATHERED BEDROCK - CLAYSTONE, brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, orange brown to gray, medium hard to hard Boring Terminated at 25.5 Feet UC 2210 12 8 13 18 25 19 18 109 112 30-19-11 5013.5 5007 4998.5 4998 4988.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49015° Longitude: -105.07559° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 8-10-10 N=20 5-7 2-2-3 N=5 8-10-15 N=25 8-21-36 N=57 0.6 15.0 16.0 20.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND (CL), light brown, medium stiff to very stiff WEATHERED BEDROCK - CLAYSTONE, light brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, gray with orange brown and white, hard Boring Terminated at 20.5 Feet 14 10 26 24 22 106 40-17-23 5012.5 4998 4997 4992.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49022° Longitude: -105.07491° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-17 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 5-8 3-3-3 N=6 4-6 15-22-30 N=52 N=50/5" 0.6 14.0 14.5 19.4 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown, medium stiff to stiff WEATHERED BEDROCK - CLAYSTONE, dark brown to orange brown, weathered SEDIMENTARY BEDROCK - CLAYSTONE, orange brown to gray, medium hard to very hard Boring Terminated at 19.4 Feet UC 2979 15 9 21 23 19 30 109 101 5015.5 5002 5001.5 4996.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49022° Longitude: -105.07431° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings after delayed water levels were measured. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-18 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins 4-6 3-3-4 N=7 2-3-4 N=7 0.6 10.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown to brown, stiff Boring Terminated at 10.5 Feet 13 20 21 5028.5 5018.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49157° Longitude: -105.07594° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings upon completion. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. P-01 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI 12-16 3-4-4 N=8 4-4-5 N=9 0.6 10.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, orange brown, stiff to very stiff Boring Terminated at 10.5 Feet 10 25 24 116 5026.5 5016.5 +6.1/150 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49111° Longitude: -105.0763° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings upon completion. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. P-02 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT 7-17 12-9 4-6-9 N=15 0.6 5.0 10.4 10.5 VEGETATIVE LAYER - 6 inches SANDY LEAN CLAY (CL), orange brown, very stiff LEAN CLAY WITH SAND, brown, very stiff WEATHERED BEDROCK - CLAYSTONE, dark brown to orange brown, weathered Boring Terminated at 10.5 Feet 10 12 20 103 96 28-16-12 5021.5 5017 5011.5 5011.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49112° Longitude: -105.07465° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings upon completion. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. P-03 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE 9-17 5-15 6-6-8 N=14 0.6 10.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown to brown, very stiff to hard Boring Terminated at 10.5 Feet 9 9 11 97 119 5025.5 5015.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49055° Longitude: -105.07661° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings upon completion. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. P-04 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) 10-16 7-8 1-1-2 N=3 0.6 5.0 10.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown, stiff to very stiff SANDY LEAN CLAY, light brown to orange brown, soft Boring Terminated at 10.5 Feet 8 10 30 110 99 5018.5 5014 5008.5 +0.2/150 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.49042° Longitude: -105.07595° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings upon completion. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. P-05 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) 6-9 4-7 5-5-7 N=12 0.6 10.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, light brown, stiff Boring Terminated at 10.5 Feet 13 16 20 114 109 5010.5 5000.5 +3.3/150 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.48988° Longitude: -105.07561° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings upon completion. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/9/2016 BORING LOG NO. P-06 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/9/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) 10-16 10-15 6-10-15 N=25 0.6 10.4 10.5 VEGETATIVE LAYER - 6 inches LEAN CLAY (CL), light brown, very stiff WEATHERED BEDROCK - CLAYSTONE, dark brown to orange brown, weathered Boring Terminated at 10.5 Feet 12 12 19 112 115 28-16-12 5012.5 5002.5 5002.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.48989° Longitude: -105.07437° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Boring backfilled with soil cuttings upon completion. 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/9/2016 BORING LOG NO. P-07 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/9/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER 10-25 8-12-15 N=27 6-8 3-4-6 N=10 9-12-17 N=29 0.6 3.0 18.0 20.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, brown to light brown, very stiff SANDY LEAN CLAY (CL), light brown, medium stiff to hard WEATHERED BEDROCK - CLAYSTONE, orange to red brown, weathered to firm Boring Terminated at 20.5 Feet 16 21 25 32 23 92 26-16-10 5007.5 5005 4990 4987.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.48969° Longitude: -105.07542° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Piezometer installed, backfilled with soil currings upon completion of delayed water level readings and removal and temporary piezometer 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/9/2016 BORING LOG NO. R-01 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/9/2016 PROJECT: Pedcor Fort Collins 7-8-8 N=16 5-6 4-6-6 N=12 12-20 12-29-30 N=59 0.6 4.0 14.0 20.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND, brown to dark brown with white, stiff to very stiff SANDY SILTY CLAY (CL-ML), brown to light brown, stiff to very stiff SEDIMENTARY BEDROCK - CLAYSTONE, dark brown to gray, firm to hard Boring Terminated at 20.5 Feet 17 17 24 22 18 108 101 25-18-7 5006.5 5003 4993 4986.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.48967° Longitude: -105.07494° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Piezometer installed, backfilled with soil currings upon completion of delayed water level readings and removal and temporary piezometer 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/9/2016 BORING LOG NO. R-02 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. 4-3-5 N=8 5-6-8 N=14 18-35 12-20-25 N=45 16-20-40 N=60 0.6 9.0 20.5 VEGETATIVE LAYER - 6 inches LEAN CLAY WITH SAND (CL), light brown, stiff to very stiff SEDIMENTARY BEDROCK - CLAYSTONE, dark brown to gray with orange brown, medium hard to hard Boring Terminated at 20.5 Feet 21 22 19 20 17 108 38-15-23 5009.5 5001 4989.5 GRAPHIC LOG StratificationAutomatic lines are approximate. In-situ, the transition may be gradual. Hammer Type: THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GEO SMART LOG-NO WELL 20165101.GPJ TERRACON2015.GDT 12/23/16 STRENGTH TEST FIELD TEST RESULTS DEPTH LOCATION Latitude: 40.4897° Longitude: -105.07447° See Exploration Plan Page 1 of 1 Advancement Method: 4-inch solid-stem augers Abandonment Method: Piezometer installed, backfilled with soil currings upon completion of delayed water level readings and removal and temporary piezometer 1901 Sharp Point Dr Ste C Fort Collins, CO Notes: Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/9/2016 BORING LOG NO. R-03 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/9/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. 0 10 20 30 40 50 60 0 20 40 60 80 100 CL or OL CH or OH ML or OL MH or OH Boring ID Depth PL PI Description SANDY LEAN CLAY LEAN CLAY with SAND SANDY LEAN CLAY SANDY LEAN CLAY SANDY LEAN CLAY LEAN CLAY with SAND FAT CLAY SANDY LEAN CLAY SANDY LEAN CLAY LEAN CLAY with SAND SANDY LEAN CLAY SANDY LEAN CLAY SANDY LEAN CLAY SANDY LEAN CLAY LEAN CLAY with SAND LEAN CLAY with SAND SANDY LEAN CLAY LEAN CLAY SANDY LEAN CLAY SANDY SILTY CLAY CL CL CL CL CL CL CH CL CL CL CL CL CL CL CL CL CL CL CL CL-ML Fines P L A S T I C 0 10 20 30 40 50 60 0 20 40 60 80 100 CL or OL CH or OH ML or OL MH or OH Boring ID Depth PL PI Description CL LEAN CLAY with SAND Fines P L A S T I C I T Y I N D E X LIQUID LIMIT "U" Line "A" Line 38 15 23 81 LL USCS R-03 ATTERBERG LIMITS RESULTS ASTM D4318 2 - 3.5 PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. ATTERBERG LIMITS 20165101.GPJ TERRACON2015.GDT 12/23/16 CL-ML 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 100 10 1 0.1 0.01 0.001 B-01 B-02 B-03 B-06 B-07 42 40 37 44 49 9.5 2 2 4.75 4.75 6 16 20 30 40 50 1.5 6 200 810 0.1 0.0 0.0 0.0 0.0 14 67.7 74.4 65.5 67.0 68.6 %Fines LL PL PI 1 4 3/4 1/2 60 fine B-01 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 100 10 1 0.1 0.01 0.001 B-08 B-09 B-10 B-11 B-12 37 69 38 28 37 0.091 2 2 2 4.75 2 6 16 20 30 40 50 1.5 6 200 810 0.0 0.0 0.0 0.0 0.0 14 80.2 99.7 66.4 50.1 72.6 %Fines LL PL PI 1 4 3/4 1/2 60 fine 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 100 10 1 0.1 0.01 0.001 B-13 B-14 B-15 B-16 B-17 37 31 39 30 40 0.078 0.086 4.75 4.75 4.75 4.75 4.75 6 16 20 30 40 50 1.5 6 200 810 0.0 0.0 0.0 0.0 0.0 14 62.4 58.0 69.5 53.3 74.0 %Fines LL PL PI 1 4 3/4 1/2 60 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 100 10 1 0.1 0.01 0.001 BULK P-03 P-07 R-01 R-02 38 28 28 26 25 0.082 0.085 4.75 4.75 4.75 4.75 9.5 6 16 20 30 40 50 1.5 6 200 810 0.0 0.0 0.0 0.0 0.1 14 78.6 65.6 89.0 57.0 53.7 %Fines LL PL PI 1 4 3/4 1/2 60 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 100 10 1 0.1 0.01 0.001 R-03 38 4.75 6 16 20 30 40 50 1.5 6 200 810 0.0 14 80.6 %Fines LL PL PI 1 4 3/4 1/2 60 fine R-03 GRAIN SIZE IN MILLIMETERS PERCENT FINER BY WEIGHT coarse fine U.HYDROMETERS. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 15 23 D100 Cc Cu SILT OR CLAY 4 D30 D10 %Gravel %Sand 2 - 3.5 3/8 3 100 3 2 140 COBBLES GRAVEL SAND USCS Classification 19.4 D60 coarse medium Boring ID Depth Boring ID Depth GRAIN SIZE DISTRIBUTION 1901 Sharp Point Drive, Suite C Fort Collins, Colorado 80525 (970) 484-0359 FAX (970) 484-0454 CLIENT: Pedcor Investments, LLC PROJECT: Pedcor Fort Collins PROJECT LOCATION: Fort Collins, Colorado DATE: 12/20/2016 SAMPLE: B-07 @ 9-10.5 feet PROJECT NO: MC% LL PI Cc Cu 22 49 30 SAMPLE LOCATION D100 D60 D30 D10 % GRAVEL % SAND % SILT % CLAY B-07 @ 9 - 10.5 feet 4.750 0.052 0.002 - 0.00 23.68 38.98 37.34 20165101 SAMPLE DESCRIPTION SANDY LEAN CLAY (CL) 0 10 20 30 40 50 60 70 80 90 100 100.000000 10.1.000 0.100 0.010 0.001 PERCENT FINER BY WEIGHT - % GRAIN SIZE IN MILLIMETERS (mm) GRAIN-SIZE DISTRIBUTION CURVE 1901 Sharp Point Drive, Suite C Fort Collins, Colorado 80525 (970) 484-0359 FAX (970) 484-0454 CLIENT: Pedcor Investments, LLC PROJECT: Pedcor Fort Collins PROJECT LOCATION: Fort Collins, Colorado DATE: 12/20/2016 SAMPLE: B-10 @ 4-5 feet PROJECT NO: MC% LL PI Cc Cu 11 38 19 SAMPLE LOCATION D100 D60 D30 D10 % GRAVEL % SAND % SILT % CLAY B-10 @ 4 - 5 feet 2.000 0.018 #N/A #N/A 0.00 33.56 27.29 39.14 20165101 SAMPLE DESCRIPTION SANDY LEAN CLAY (CL) 0 10 20 30 40 50 60 70 80 90 100 100.000000 10.1.000 0.100 0.010 0.001 PERCENT FINER BY WEIGHT - % GRAIN SIZE IN MILLIMETERS (mm) GRAIN-SIZE DISTRIBUTION CURVE 1901 Sharp Point Drive, Suite C Fort Collins, Colorado 80525 (970) 484-0359 FAX (970) 484-0454 CLIENT: Pedcor Investments, LLC PROJECT: Pedcor Fort Collins PROJECT LOCATION: Fort Collins, Colorado DATE: 12/21/2016 SAMPLE: B-15 @ 4-5 feet PROJECT NO: MC% LL PI Cc Cu 14 39 22 SAMPLE LOCATION D100 D60 D30 D10 % GRAVEL % SAND % SILT % CLAY B-15 @ 4 - 5 feet 4.750 0.060 0.002 - 0.00 30.46 33.82 35.71 20165101 SAMPLE DESCRIPTION LEAN CLAY WITH SAND 0 10 20 30 40 50 60 70 80 90 100 100.000000 10.1.000 0.100 0.010 0.001 PERCENT FINER BY WEIGHT - % GRAIN SIZE IN MILLIMETERS (mm) GRAIN-SIZE DISTRIBUTION CURVE 1901 Sharp Point Drive, Suite C Fort Collins, Colorado 80525 (970) 484-0359 FAX (970) 484-0454 CLIENT: Pedcor Investments, LLC PROJECT: Pedcor Fort Collins PROJECT LOCATION: Fort Collins, Colorado DATE: 12/21/2016 SAMPLE: B-17 @ 2-3.5 feet PROJECT NO: MC% LL PI Cc Cu 14 40 23 SAMPLE LOCATION D100 D60 D30 D10 % GRAVEL % SAND % SILT % CLAY B-17 @ 2 - 3.5 feet 4.750 0.046 0.002 - 0.00 25.98 35.35 38.68 20165101 SAMPLE DESCRIPTION LEAN CLAY WITH SAND 0 10 20 30 40 50 60 70 80 90 100 100.000000 10.1.000 0.100 0.010 0.001 PERCENT FINER BY WEIGHT - % GRAIN SIZE IN MILLIMETERS (mm) GRAIN-SIZE DISTRIBUTION CURVE -4 -3 -2 -1 0 1 2 3 4 5 6 7 100 1,000 10,000 AXIAL STRAIN, % PRESSURE, psf SWELL CONSOLIDATION TEST ASTM D4546 NOTES: Sample exhibited 1.1 percent swell upon wetting under an applied pressure of 1,000 psf. Specimen Identification Classification , pcf B-05 108 18 WC, % 14 - 15 ft PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. TC_CONSOL_STRAIN-USCS 20165101.GPJ TERRACON2012.GDT 12/22/16 CLAYSTONE BEDROCK -4 -3 -2 -1 0 1 2 3 4 5 6 7 100 1,000 10,000 AXIAL STRAIN, % PRESSURE, psf SWELL CONSOLIDATION TEST ASTM D4546 NOTES: Sample exhibited 1.1 percent swell upon wetting under an applied pressure of 500 psf. Specimen Identification Classification , pcf B-10 112 11 WC, % 4 - 5 ft SANDY LEAN CLAY(CL) PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. TC_CONSOL_STRAIN-USCS 20165101.GPJ TERRACON2012.GDT 12/22/16 -4 -3 -2 -1 0 1 2 3 4 5 6 7 100 1,000 10,000 AXIAL STRAIN, % PRESSURE, psf SWELL CONSOLIDATION TEST ASTM D4546 NOTES: Sample exhibited 0.9 percent compression upon wetting under an applied pressure of 1,000 psf. Specimen Identification Classification , pcf B-11 103 16 WC, % 9 - 10 ft SANDY LEAN CLAY(CL) PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. TC_CONSOL_STRAIN-USCS 20165101.GPJ TERRACON2012.GDT 12/22/16 -4 -3 -2 -1 0 1 2 3 4 5 6 7 100 1,000 10,000 AXIAL STRAIN, % PRESSURE, psf SWELL CONSOLIDATION TEST ASTM D4546 NOTES: Sample exhibited no movement upon wetting under an applied pressure of 1,000 psf Specimen Identification Classification , pcf B-14 119 10 WC, % 9 - 10 ft SANDY LEAN CLAY(CL) PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. TC_CONSOL_STRAIN-USCS 20165101.GPJ TERRACON2012.GDT 12/22/16 -4 -3 -2 -1 0 1 2 3 4 5 6 7 100 1,000 10,000 AXIAL STRAIN, % PRESSURE, psf SWELL CONSOLIDATION TEST ASTM D4546 NOTES: Sample exhibited 6.1 percent swell upon wetting under an applied pressure of 150 psf. Specimen Identification Classification , pcf P-02 116 10 WC, % 2 - 3 ft PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. TC_CONSOL_STRAIN-USCS 20165101.GPJ TERRACON2012.GDT 12/22/16 LEAN CLAY with SAND -4 -3 -2 -1 0 1 2 3 4 5 6 7 100 1,000 10,000 AXIAL STRAIN, % PRESSURE, psf SWELL CONSOLIDATION TEST ASTM D4546 NOTES: Sample exhibited 0.2 percent swell upon wetting under an applied pressure of 150 psf. Specimen Identification Classification , pcf P-05 110 8 WC, % 2 - 3 ft PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. TC_CONSOL_STRAIN-USCS 20165101.GPJ TERRACON2012.GDT 12/22/16 LEAN CLAY with SAND -4 -3 -2 -1 0 1 2 3 4 5 6 7 100 1,000 10,000 AXIAL STRAIN, % PRESSURE, psf SWELL CONSOLIDATION TEST ASTM D4546 NOTES: Sample exhibited 3.3 percent swell upon wetting under an applied pressure of 150 psf. Specimen Identification Classification , pcf P-06 114 13 WC, % 2 - 3 ft PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. TC_CONSOL_STRAIN-USCS 20165101.GPJ TERRACON2012.GDT 12/22/16 LEAN CLAY with SAND 0 500 1,000 1,500 2,000 2,500 3,000 3,500 0 4 8 12 16 LL PL PI 2.40 5.87 Percent < #200 Sieve AXIAL STRAIN - % Remarks: SPECIMEN FAILURE PHOTOGRAPH SAMPLE DESCRIPTION: LEAN CLAY WITH SAND Unconfined Compressive Strength (psf) Undrained Shear Strength: (psf) UNCONFINED COMPRESSION TEST ASTM D2166 868 SAMPLE TYPE: D&M RING Assumed Specific Gravity: Calculated Void Ratio: Height / Diameter Ratio: SPECIMEN TEST DATA 2.45 14.64 Moisture Content: % Dry Density: pcf Diameter: in. Height: in. Calculated Saturation: % Failure Strain: % Strain Rate: in/min COMPRESSIVE STRESS - psf 23 106 1737 SAMPLE LOCATION: B-02 @ 9 - 10 feet PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. UNCONFINED WITH PHOTOS 20165101.GPJ TERRACON2012.GDT 12/23/16 0 500 1,000 1,500 2,000 2,500 3,000 3,500 0 4 8 12 16 LL PL PI 2.40 5.90 Percent < #200 Sieve AXIAL STRAIN - % Remarks: SPECIMEN FAILURE PHOTOGRAPH SAMPLE DESCRIPTION: LEAN CLAY WITH SAND Unconfined Compressive Strength (psf) Undrained Shear Strength: (psf) UNCONFINED COMPRESSION TEST ASTM D2166 771 SAMPLE TYPE: D&M RING Assumed Specific Gravity: Calculated Void Ratio: Height / Diameter Ratio: SPECIMEN TEST DATA 2.46 11.86 Moisture Content: % Dry Density: pcf Diameter: in. Height: in. Calculated Saturation: % Failure Strain: % Strain Rate: in/min COMPRESSIVE STRESS - psf 24 103 1541 SAMPLE LOCATION: B-04 @ 9 - 10 feet PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. UNCONFINED WITH PHOTOS 20165101.GPJ TERRACON2012.GDT 12/23/16 0 500 1,000 1,500 2,000 2,500 3,000 3,500 0 4 8 12 16 LL PL PI 2.40 6.00 Percent < #200 Sieve 53 AXIAL STRAIN - % Remarks: SPECIMEN FAILURE PHOTOGRAPH SAMPLE DESCRIPTION: SANDY LEAN CLAY(CL) 30 19 11 Unconfined Compressive Strength (psf) Undrained Shear Strength: (psf) UNCONFINED COMPRESSION TEST ASTM D2166 1105 SAMPLE TYPE: D&M RING Assumed Specific Gravity: Calculated Void Ratio: Height / Diameter Ratio: SPECIMEN TEST DATA 2.50 12.00 Moisture Content: % Dry Density: pcf Diameter: in. Height: in. Calculated Saturation: % Failure Strain: % Strain Rate: in/min COMPRESSIVE STRESS - psf 18 112 2210 SAMPLE LOCATION: B-16 @ 9 - 10 feet PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. UNCONFINED WITH PHOTOS 20165101.GPJ TERRACON2012.GDT 12/23/16 0 500 1,000 1,500 2,000 2,500 3,000 3,500 0 4 8 12 16 LL PL PI 2.40 5.50 Percent < #200 Sieve AXIAL STRAIN - % Remarks: SPECIMEN FAILURE PHOTOGRAPH SAMPLE DESCRIPTION: LEAN CLAY WITH SAND Unconfined Compressive Strength (psf) Undrained Shear Strength: (psf) UNCONFINED COMPRESSION TEST ASTM D2166 1490 SAMPLE TYPE: D&M RING Assumed Specific Gravity: Calculated Void Ratio: Height / Diameter Ratio: SPECIMEN TEST DATA 2.29 15.00 Moisture Content: % Dry Density: pcf Diameter: in. Height: in. Calculated Saturation: % Failure Strain: % Strain Rate: in/min COMPRESSIVE STRESS - psf 23 101 2979 SAMPLE LOCATION: B-18 @ 9 - 10 feet PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. UNCONFINED WITH PHOTOS 20165101.GPJ TERRACON2012.GDT 12/23/16 1901 Sharp Point Drive, Suite C Fort Collins, Colorado 80525 (970) 484-0359 FAX (970) 484-0454 CLIENT: DATE OF TEST: 16-Dec-16 PROJECT: Pedcor Fort Collins LOCATION: Bulk - from top 5 feet of P-01 through P-07 TERRACON NO. 20165101 CLASSIFICATION: LEAN CLAY with SAND (CL) TEST SPECIMEN NO. 1 2 3 COMPACTION PRESSURE (PSI) 20 60 280 DENSITY (PCF) 94.6 102.2 113.4 MOISTURE CONTENT (%) 31.5 25.3 16.3 EXPANSION PRESSURE (PSI) -0.12 -0.07 0.08 HORIZONTAL PRESSURE @ 160 PSI 148 125 121 SAMPLE HEIGHT (INCHES) 2.64 2.67 2.36 EXUDATION PRESSURE (PSI) 143.3 381.9 618.6 CORRECTED R-VALUE 3.9 13.3 24.5 UNCORRECTED R-VALUE 3.7 12.5 25.9 R-VALUE @ 300 PSI EXUDATION PRESSURE = 10 AASHTO T190 PRESSURE OF COMPACTED SOIL RESISTANCE R-VALUE & EXPANSION SAMPLE DATA TEST RESULTS 0 10 20 30 40 50 60 70 80 90 100 0 100 200 300 400 500 600 700 800 R-VALUE EXUDATION PRESSURE - PSI Pedcor Investments, LLC TASK NO: 161220027 Analytical Results Terracon, Inc. - Fort Collins Eric D. Bernhardt Company: Report To: Company: Bill To: 1901 Sharp Point Drive Suite C Fort Collins CO 80525 Accounts Payable Terracon, Inc. - A/P 18001 W. 106th St Suite 300 Olathe KS 66061 Pedlor Fort Collins 20165101 Date Reported: 12/27/16 Task No.: 161220027 Matrix: Soil - Geotech Date Received: 12/20/16 Client Project: Client PO: Customer4ft Sample ID B8 @ Test Method Lab Number: 161220027-01 Result Sulfate - Water Soluble 0.023 % AASHTO T290-91/ ASTM D4327 Customer Sample ID B10 @ 9ft Test Method Lab Number: 161220027-02 Result Sulfate - Water Soluble 0.004 % AASHTO T290-91/ ASTM D4327 Customer Sample ID B17 @ 4ft Test Method Lab Number: 161220027-03 Result Sulfate - Water Soluble 0.011 % AASHTO T290-91/ ASTM D4327 Customer2ft Sample ID P1 @ Test Method Lab Number: 161220027-04 Result Sulfate - Water Soluble 0.026 % AASHTO T290-91/ ASTM D4327 Customer2ft Sample ID P4 @ Test Method Lab Number: 161220027-05 Result Sulfate - Water Soluble 0.013 % AASHTO T290-91/ ASTM D4327 240 South Main Street / Brighton, CO 80601-0507 / 303-659-2313 Mailing Address: P.O. Box 507 / Brighton, CO 80601-0507 / Fax: 303-659-2315 DATA APPROVED FOR RELEASE BY Abbreviations/ References: 161220027 AASHTO - American Association of State Highway and Transportation Officials. ASTM - American Society for Testing and Materials. ASA - American Society of Agronomy. DIPRA - Ductile Iron Pipe Research Association Handbook of Ductile Iron Pipe. TASK NO: 161220027 Analytical Results Terracon, Inc. - Fort Collins Eric D. Bernhardt Company: Report To: Company: Bill To: 1901 Sharp Point Drive Suite C Fort Collins CO 80525 Accounts Payable Terracon, Inc. - A/P 18001 W. 106th St Suite 300 Olathe KS 66061 Pedlor Fort Collins 20165101 Date Reported: 12/27/16 Task No.: 161220027 Matrix: Soil - Geotech Date Received: 12/20/16 Client Project: Client PO: Customer Sample ID R3 @ 4ft Test Method Lab Number: 161220027-06 Result Sulfate - Water Soluble 0.865 % AASHTO T290-91/ ASTM D4327 240 South Main Street / Brighton, CO 80601-0507 / 303-659-2313 Mailing Address: P.O. Box 507 / Brighton, CO 80601-0507 / Fax: 303-659-2315 DATA APPROVED FOR RELEASE BY Abbreviations/ References: 161220027 AASHTO - American Association of State Highway and Transportation Officials. ASTM - American Society for Testing and Materials. ASA - American Society of Agronomy. DIPRA - Ductile Iron Pipe Research Association Handbook of Ductile Iron Pipe. Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Photo No. 1: Irrigation ditch on north side of the site Photo No. 2: South side of the site with Robert Benson Lake Pedcor Fort Collins Fort Collins, Colorado January 12, 2017 Terracon Project No. 20165101 Responsive Resourceful Reliable Photo No. 3: East side of site Photo No. 4: West side of site 12/23/2016 20165101 Pedcor Fort Collins Fort Collins, Colorado 500 to 1,000 > 8,000 4,000 to 8,000 2,000 to 4,000 1,000 to 2,000 less than 500 Unconfined Compressive Strength Qu, (psf) Modified Dames & Moore Ring Sampler Standard Penetration Test Trace PLASTICITY DESCRIPTION Water levels indicated on the soil boring logs are the levels measured in the borehole at the times indicated. Groundwater level variations will occur over time. In low permeability soils, accurate determination of groundwater levels is not possible with short term water level observations. DESCRIPTION OF SYMBOLS AND ABBREVIATIONS GENERAL NOTES > 30 11 - 30 Low 1 - 10 Non-plastic Plasticity Index #4 to #200 sieve (4.75mm to 0.075mm Boulders Cobbles 12 in. to 3 in. (300mm to 75mm) Gravel 3 in. to #4 sieve (75mm to 4.75 mm) Sand Silt or Clay Passing #200 sieve (0.075mm) Particle Size Water Level After a Specified Period of Time Water Level After a Specified Period of Time Water Initially Encountered Soil classification is based on the Unified Soil Classification System. Coarse Grained Soils have more than 50% of their dry weight retained on a #200 sieve; their principal descriptors are: boulders, cobbles, gravel or sand. Fine Grained Soils have less than 50% of their dry weight retained on a #200 sieve; they are principally described as clays if they are plastic, and silts if they are slightly plastic or non-plastic. Major constituents may be added as modifiers and minor constituents may be added according to the relative proportions based on grain size. In addition to gradation, coarse-grained soils are defined on the basis of their in-place relative density and fine-grained soils on the basis of their consistency. Unless otherwise noted, Latitude and Longitude are approximately determined using a hand-held GPS device. The accuracy of such devices is variable. Surface elevation data annotated with +/- indicates that no ctual topographical survey was conducted to confirm the surface elevation. Instead, the surface elevation was approximately determined from topographic maps of the area. GRAIN SIZE TERMINOLOGY RELATIVE PROPORTIONS OF SAND AND GRAVEL RELATIVE PROPORTIONS OF FINES DESCRIPTIVE SOIL CLASSIFICATION LOCATION AND ELEVATION NOTES SAMPLING WATER LEVEL FIELD TESTS UNIFIED SOIL CLASSIFICATION SYSTEM Criteria for Assigning Group Symbols and Group Names Using Laboratory Tests A Soil Classification Group Symbol Group Name B Coarse Grained Soils: More than 50% retained on No. 200 sieve Gravels: More than 50% of coarse fraction retained on No. 4 sieve Clean Gravels: Less than 5% fines C Cu 4 and 1 Cc 3 E GW Well-graded gravel F Cu 4 and/or 1 Cc 3 E GP Poorly graded gravel F Gravels with Fines: More than 12% fines C Fines classify as ML or MH GM Silty gravel F,G,H Fines classify as CL or CH GC Clayey gravel F,G,H Sands: 50% or more of coarse fraction passes No. 4 sieve Clean Sands: Less than 5% fines D Cu 6 and 1 Cc 3 E SW Well-graded sand I Cu 6 and/or 1 Cc 3 E SP Poorly graded sand I Sands with Fines: More than 12% fines D Fines classify as ML or MH SM Silty sand G,H,I Fines classify as CL or CH SC Clayey sand G,H,I Fine-Grained Soils: 50% or more passes the No. 200 sieve Silts and Clays: Liquid limit less than 50 Inorganic: PI 7 and plots on or above “A” line J CL Lean clay K,L,M PI 4 or plots below “A” line J ML Silt K,L,M Organic: Liquid limit - oven dried 0.75 OL Organic clay K,L,M,N Liquid limit - not dried Organic silt K,L,M,O Silts and Clays: Liquid limit 50 or more Inorganic: PI plots on or above “A” line CH Fat clay K,L,M PI plots below “A” line MH Elastic Silt K,L,M Organic: Liquid limit - oven dried 0.75 OH Organic clay K,L,M,P Liquid limit - not dried Organic silt K,L,M,Q Highly organic soils: Primarily organic matter, dark in color, and organic odor PT Peat A Based on the material passing the 3-inch (75-mm) sieve B If field sample contained cobbles or boulders, or both, add “with cobbles or boulders, or both” to group name. C Gravels with 5 to 12% fines require dual symbols: GW-GM well-graded DESCRIPTION OF ROCK PROPERTIES WEATHERING Fresh Rock fresh, crystals bright, few joints may show slight staining. Rock rings under hammer if crystalline. Very slight Rock generally fresh, joints stained, some joints may show thin clay coatings, crystals in broken face show bright. Rock rings under hammer if crystalline. Slight Rock generally fresh, joints stained, and discoloration extends into rock up to 1 in. Joints may contain clay. In granitoid rocks some occasional feldspar crystals are dull and discolored. Crystalline rocks ring under hammer. Moderate Significant portions of rock show discoloration and weathering effects. In granitoid rocks, most feldspars are dull and discolored; some show clayey. Rock has dull sound under hammer and shows significant loss of strength as compared with fresh rock. Moderately severe All rock except quartz discolored or stained. In granitoid rocks, all feldspars dull and discolored and majority show kaolinization. Rock shows severe loss of strength and can be excavated with geologist’s pick. Severe All rock except quartz discolored or stained. Rock “fabric” clear and evident, but reduced in strength to strong soil. In granitoid rocks, all feldspars kaolinized to some extent. Some fragments of strong rock usually left. Very severe All rock except quartz discolored or stained. Rock “fabric” discernible, but mass effectively reduced to “soil” with only fragments of strong rock remaining. Complete Rock reduced to ”soil”. Rock “fabric” not discernible or discernible only in small, scattered locations. Quartz may be present as dikes or stringers. HARDNESS (for engineering description of rock – not to be confused with Moh’s scale for minerals) Very hard Cannot be scratched with knife or sharp pick. Breaking of hand specimens requires several hard blows of geologist’s pick. Hard Can be scratched with knife or pick only with difficulty. Hard blow of hammer required to detach hand specimen. Moderately hard Can be scratched with knife or pick. Gouges or grooves to ¼ in. deep can be excavated by hard blow of point of a geologist’s pick. Hand specimens can be detached by moderate blow. Medium Can be grooved or gouged 1/16 in. deep by firm pressure on knife or pick point. Can be excavated in small chips to pieces about 1-in. maximum size by hard blows of the point of a geologist’s pick. Soft Can be gouged or grooved readily with knife or pick point. Can be excavated in chips to pieces several inches in size by moderate blows of a pick point. Small thin pieces can be broken by finger pressure. Very soft Can be carved with knife. Can be excavated readily with point of pick. Pieces 1-in. or more in thickness can be broken with finger pressure. Can be scratched readily by fingernail. Joint, Bedding, and Foliation Spacing in Rock a Spacing Joints Bedding/Foliation Less than 2 in. Very close Very thin 2 in. – 1 ft. Close Thin 1 ft. – 3 ft. Moderately close Medium 3 ft. – 10 ft. Wide Thick More than 10 ft. Very wide Very thick a. Spacing refers to the distance normal to the planes, of the described feature, which are parallel to each other or nearly so. Rock Quality Designator (RQD) a Joint Openness Descriptors RQD, as a percentage Diagnostic description Openness Descriptor Exceeding 90 Excellent No Visible Separation Tight 90 – 75 Good Less than 1/32 in. Slightly Open 75 – 50 Fair 1/32 to 1/8 in. Moderately Open 50 – 25 Poor 1/8 to 3/8 in. Open Less than 25 Very poor 3/8 in. to 0.1 ft. Moderately Wide a. RQD (given as a percentage) = length of core in pieces Greater than 0.1 ft. Wide 4 in. and longer/length of run. References: American Society of Civil Engineers. Manuals and Reports on Engineering Practice - No. 56. Subsurface Investigation for Design and Construction of Foundations of Buildings. New York: American Society of Civil Engineers, 1976. U.S. Department of the Interior, Bureau of Reclamation, Engineering Geology Field Manual. gravel with silt, GW-GC well-graded gravel with clay, GP-GM poorly graded gravel with silt, GP-GC poorly graded gravel with clay. D Sands with 5 to 12% fines require dual symbols: SW-SM well-graded sand with silt, SW-SC well-graded sand with clay, SP-SM poorly graded sand with silt, SP-SC poorly graded sand with clay E Cu = D60/D10 Cc = 10 60 2 30 D x D (D ) F If soil contains 15% sand, add “with sand” to group name. G If fines classify as CL-ML, use dual symbol GC-GM, or SC-SM. H If fines are organic, add “with organic fines” to group name. I If soil contains 15% gravel, add “with gravel” to group name. J If Atterberg limits plot in shaded area, soil is a CL-ML, silty clay. K If soil contains 15 to 29% plus No. 200, add “with sand” or “with gravel,” whichever is predominant. L If soil contains 30% plus No. 200 predominantly sand, add “sandy” to group name. M If soil contains 30% plus No. 200, predominantly gravel, add “gravelly” to group name. N PI 4 and plots on or above “A” line. O PI 4 or plots below “A” line. P PI plots on or above “A” line. Q PI plots below “A” line. N (HP) (T) (DCP) UC (PID) (OVA) Standard Penetration Test Resistance (Blows/Ft.) Hand Penetrometer Torvane Dynamic Cone Penetrometer Unconfined Compressive Strength Photo-Ionization Detector Organic Vapor Analyzer Medium Over 12 in. (300 mm) 0 >12 5-12 <5 Percent of Dry Weight Major Component of Sample Term Modifier With Trace Descriptive Term(s) of other constituents Modifier >30 <15 Percent of Dry Weight Descriptive Term(s) of other constituents With 15-29 High Standard Penetration or N-Value Blows/Ft. Descriptive Term (Density) CONSISTENCY OF FINE-GRAINED SOILS Hard Very Dense > 50 Very Stiff 15 - 30 Dense 30 - 50 Stiff 8 - 15 Medium Dense 10 - 29 Medium8 Stiff 4 - Loose9 4Soft4 - 2 - Very3 Loose 0 - Very1 Soft 0 - (50% or more passing the No. 200 sieve.) Consistency determined by laboratory shear strength testing, field visual-manual procedures or standard penetration resistance STRENGTH TERMS > 30 Descriptive Term (Consistency) Standard Penetration or N-Value Blows/Ft. RELATIVE DENSITY OF COARSE-GRAINED SOILS (More than 50% retained on No. 200 sieve.) Density determined by Standard Penetration Resistance 2 - 3.5 LEAN CLAY with SAND (CL) ASTM D422 / ASTM C136 PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GRAIN SIZE: USCS-2 20165101.GPJ 35159097 - ATTERBERG ISSUE.GPJ 12/23/16 fine BULK P-03 P-07 R-01 R-02 GRAIN SIZE IN MILLIMETERS PERCENT FINER BY WEIGHT coarse fine U.HYDROMETERS. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 14 16 16 16 18 24 12 12 10 7 D100 Cc Cu SILT OR CLAY 4 D30 D10 %Gravel %Sand 1 - 6 2 - 3 4 - 5 9 - 10 9 - 10.5 3/8 3 100 3 2 140 COBBLES GRAVEL SAND USCS Classification 21.4 34.4 11.0 43.0 46.3 D60 coarse medium Boring ID Depth Boring ID Depth GRAIN SIZE DISTRIBUTION 1 - 6 2 - 3 4 - 5 9 - 10 9 - 10.5 LEAN CLAY with SAND (CL) SANDY LEAN CLAY (CL) LEAN CLAY (CL) SANDY LEAN CLAY (CL) SANDY SILTY CLAY (CL-ML) ASTM D422 / ASTM C136 PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GRAIN SIZE: USCS-2 20165101.GPJ 35159097 - ATTERBERG ISSUE.GPJ 12/23/16 fine B-13 B-14 B-15 B-16 B-17 GRAIN SIZE IN MILLIMETERS PERCENT FINER BY WEIGHT coarse fine U.HYDROMETERS. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 18 18 17 19 17 19 13 22 11 23 D100 Cc Cu SILT OR CLAY 4 D30 D10 %Gravel %Sand 4 - 5 9 - 10 4 - 5 9 - 10 2 - 3.5 3/8 3 100 3 2 140 COBBLES GRAVEL SAND USCS Classification 37.6 42.0 30.5 46.7 26.0 D60 coarse medium Boring ID Depth Boring ID Depth GRAIN SIZE DISTRIBUTION 4 - 5 9 - 10 4 - 5 9 - 10 2 - 3.5 SANDY LEAN CLAY (CL) SANDY LEAN CLAY (CL) SANDY LEAN CLAY (CL) SANDY LEAN CLAY (CL) LEAN CLAY with SAND (CL) ASTM D422 / ASTM C136 PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GRAIN SIZE: USCS-2 20165101.GPJ 35159097 - ATTERBERG ISSUE.GPJ 12/23/16 B-08 B-09 B-10 B-11 B-12 GRAIN SIZE IN MILLIMETERS PERCENT FINER BY WEIGHT coarse fine U.HYDROMETERS. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 19 31 19 14 16 18 38 19 14 21 D100 Cc Cu SILT OR CLAY 4 D30 D10 %Gravel %Sand 2 - 3.5 14 - 15.5 4 - 5 9 - 10 9 - 10 3/8 3 100 3 2 140 COBBLES GRAVEL SAND USCS Classification 19.8 0.3 33.6 49.9 27.4 D60 coarse medium Boring ID Depth Boring ID Depth GRAIN SIZE DISTRIBUTION 2 - 3.5 14 - 15.5 4 - 5 9 - 10 9 - 10 LEAN CLAY with SAND (CL) FAT CLAY (CH) SANDY LEAN CLAY (CL) SANDY LEAN CLAY (CL) LEAN CLAY with SAND (CL) ASTM D422 / ASTM C136 PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GRAIN SIZE: USCS-2 20165101.GPJ 35159097 - ATTERBERG ISSUE.GPJ 12/23/16 B-02 B-03 B-06 B-07 GRAIN SIZE IN MILLIMETERS PERCENT FINER BY WEIGHT coarse fine U.HYDROMETERS. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 18 16 18 17 19 24 24 19 27 30 D100 Cc Cu SILT OR CLAY 4 D30 D10 %Gravel %Sand 4 - 5 4 - 5.5 2 - 3.5 4 - 5.5 9 - 10.5 3/8 3 100 3 2 140 COBBLES GRAVEL SAND USCS Classification 32.2 25.6 34.5 33.0 31.4 D60 coarse medium Boring ID Depth Boring ID Depth GRAIN SIZE DISTRIBUTION 4 - 5 4 - 5.5 2 - 3.5 4 - 5.5 9 - 10.5 SANDY LEAN CLAY (CL) LEAN CLAY with SAND (CL) SANDY LEAN CLAY (CL) SANDY LEAN CLAY (CL) SANDY LEAN CLAY (CL) ASTM D422 / ASTM C136 PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. GRAIN SIZE: USCS-2 20165101.GPJ 35159097 - ATTERBERG ISSUE.GPJ 12/23/16 I T Y I N D E X LIQUID LIMIT "U" Line "A" Line 42 40 37 44 49 37 69 38 28 37 37 31 39 30 40 38 28 28 26 25 18 16 18 17 19 19 31 19 14 16 18 18 17 19 17 14 16 16 16 18 24 24 19 27 30 18 38 19 14 21 19 13 22 11 23 24 12 12 10 7 68 74 65 67 69 80 100 66 50 73 62 58 70 53 74 79 66 89 57 54 LL USCS B-01 B-02 B-03 B-06 B-07 B-08 B-09 B-10 B-11 B-12 B-13 B-14 B-15 B-16 B-17 BULK P-03 P-07 R-01 R-02 ATTERBERG LIMITS RESULTS ASTM D4318 4 - 5 4 - 5.5 2 - 3.5 4 - 5.5 9 - 10.5 2 - 3.5 14 - 15.5 4 - 5 9 - 10 9 - 10 4 - 5 9 - 10 4 - 5 9 - 10 2 - 3.5 1 - 6 2 - 3 4 - 5 9 - 10 9 - 10.5 PROJECT NUMBER: 20165101 PROJECT: Pedcor Fort Collins SITE: North College Avenue and Trilby Road Fort Collins, Colorado CLIENT: Pedcor Investments, LLC Carmel, Indiana 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. ATTERBERG LIMITS 20165101.GPJ TERRACON2015.GDT 12/23/16 CL-ML North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 6.6' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5010 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) Boring Completed: 12/9/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 9.6' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5007 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: 11' while drilling 8.7' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5008 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5013 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 SWELL / LOAD (%/psf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5011 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 SWELL / LOAD (%/psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5019 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 SWELL / LOAD (%/psf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5026 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 SWELL / LOAD (%/psf) COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5022 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 SWELL / LOAD (%/psf) WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5027 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 SWELL / LOAD (%/psf) ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5029 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 SWELL / LOAD (%/psf) See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: 18' while drilling 11.9' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5016 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 SWELL / LOAD (%/psf) PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5013 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) Boring Started: 12/8/2016 BORING LOG NO. B-16 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 10.1' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5014 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 25 SWELL / LOAD (%/psf) Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: 17' while drilling 12.8' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5016 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 25 SWELL / LOAD (%/psf) Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-14 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 13.8' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5023 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 25 SWELL / LOAD (%/psf) Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5015 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5021 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-11 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 22.8' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5025 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) Drill Rig: CME-55 Boring Started: 12/7/2016 BORING LOG NO. B-10 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 13.7' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5019 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 25 SWELL / LOAD (%/psf) See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5018 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 13.3' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5022 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) Driller: Drilling Engineers, Inc. Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 20.4' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5025 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) Project No.: 20165101 Drill Rig: CME-55 Boring Started: 12/8/2016 BORING LOG NO. B-06 CLIENT: Pedcor Investments, LLC Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 13.6' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5029 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 SWELL / LOAD (%/psf) Carmel, Indiana Driller: Drilling Engineers, Inc. Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: 9' while drilling 13' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5022 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: 13' while drilling 13.7' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5025 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) Boring Completed: 12/7/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: 10.5' while drilling 10.2' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5028 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 25 SWELL / LOAD (%/psf) Boring Completed: 12/8/2016 PROJECT: Pedcor Fort Collins See Supporting Information for explanation of symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 11.1' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 8029 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf) symbols and abbreviations. North College Avenue and Trilby Road Fort Collins, Colorado SITE: No free water observed while drilling 11.6' on 12/14/2016 WATER LEVEL OBSERVATIONS TEST TYPE COMPRESSIVE STRENGTH (psf) STRAIN (%) WATER CONTENT (%) DRY UNIT WEIGHT (pcf) LL-PL-PI ATTERBERG LIMITS ELEVATION (Ft.) Surface Elev.: 5032 (Ft.) SAMPLE TYPE WATER LEVEL OBSERVATIONS DEPTH (Ft.) 5 10 15 20 SWELL / LOAD (%/psf)