Loading...
HomeMy WebLinkAboutSCHRADER PROPANE OFFICE & MINOR VEHICLE REPAIR - PDP - PDP170015 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTPRELIMINARY DRAINAGE AND EROSION CONTROL REPORT April 11, 2017 Schrader Propane Offices Fort Collins, Colorado Prepared for: Schrader Propane 320 North College Avenue Fort Collins, CO 80524 970-484-1225 Prepared by: 301 N. Howes Street, Suite 100 Fort Collins, Colorado 80521 Phone: 970.221.4158 www.northernengineering.com Project Number: 146-011  This Drainage Report is consciously provided as a PDF. Please consider the environment before printing this document in its entirety. When a hard copy is absolutely necessary, we recommend double-sided printing. RE: Preliminary Drainage and Erosion Control Report for Schrader Propane Offices Dear Staff: Northern Engineering is pleased to submit this Preliminary Drainage and Erosion Control Report for your review. This report accompanies Project Development Plan submittal for the proposed Schrader Propane Offices development. This report has been prepared in accordance to Fort Collins Stormwater Criteria Manual (FCSCM), and serves to document the stormwater impacts associated with the proposed project. We understand that review by the City is to assure general compliance with standardized criteria contained in the FCSCM. If you should have any questions as you review this report, please feel free to contact us. Sincerely, NORTHERN ENGINEERING SERVICES, INC. Stephanie Thomas, PE Project Engineer Schrader Propane Offices Preliminary Drainage Report TABLE OF CONTENTS I. GENERAL LOCATION AND DESCRIPTION ................................................................... 1 A. Location ....................................................................................................................................... 1 B. Description of Property ................................................................................................................ 2 C. Floodplain .................................................................................................................................... 3 II. DRAINAGE BASINS AND SUB-BASINS ....................................................................... 4 A. Major Basin Description ............................................................................................................... 4 B. Sub-Basin Description .................................................................................................................. 4 III. DRAINAGE DESIGN CRITERIA ................................................................................... 5 A. Regulations .................................................................................................................................. 5 B. Four Step Process ........................................................................................................................ 5 C. Development Criteria Reference and Constraints ......................................................................... 6 D. Hydrological Criteria .................................................................................................................... 6 E. Hydraulic Criteria ......................................................................................................................... 6 F. Floodplain Regulations Compliance .............................................................................................. 6 G. Modifications of Criteria .............................................................................................................. 6 IV. DRAINAGE FACILITY DESIGN .................................................................................... 7 A. General Concept .......................................................................................................................... 7 B. Specific Details ............................................................................................................................. 9 V. CONCLUSIONS ........................................................................................................ 9 A. Compliance with Standards .......................................................................................................... 9 B. Drainage Concept ........................................................................................................................ 9 References ....................................................................................................................... 10 APPENDICES: APPENDIX A – Hydrologic Computations APPENDIX B – Hydraulic Computations (NOT INCLUDED WITH PDP) B.1 – Detention Ponds and Water Quality B.2 – Storm Sewers (NOT INCLUDED WITH PDP) B.3 – Inlets (NOT INCLUDED WITH PDP) APPENDIX C – Erosion Control Report APPENDIX D – LID Exhibit APPENDIX E – References Schrader Propane Offices Preliminary Drainage Report LIST OF TABLES AND FIGURES: Figure 1 – Aerial Photograph ................................................................................................ 2 Figure 2– Proposed Site Plan ................................................................................................ 3 Figure 3 – Existing Floodplains ............................................................................................. 4 MAP POCKET: DR1 - Drainage Exhibit Schrader Propane Offices Preliminary Drainage Report 1 I. GENERAL LOCATION AND DESCRIPTION A. Location 1. Vicinity Map 2. Located in the northwest quarter of Section 1, Township 7 North, Range 69 West of the 6th Prime Meridian, City of Fort Collins, County of Larimer, State of Colorado. The site is a replat of Lots 15 and 16, Block 3, of Evergreen Park. 3. Bounded to the north by industrial lot, to the west by an existing alley, to the south by undeveloped lot and transmission lines, and to the east by public right of way for Red Cedar Circle. 4. No significant offsite flows are directed into the site. The majority of off-site flows are are prevented from entering the site by existing topography. 5. Lots 15 and 16, Block 3 was originally included in the Master Storm Drainage and Detention Plan for Evergreen Park, prepared by Cornell Consulting Company. The Drainage Plan for the area has been revised per the North East College Corridor Outfall Schrader Propane Offices Preliminary Drainage Report 2 (NECCO) project commissioned by The City of Fort Collins and designed by Ayres Associates. 6. The NECCO project overrides the existing drainage plan for the Evergreen Park Subdivision. B. Description of Property 1. The site is approximately 1.63 acres with 1.06 acres planned for development. Figure 1 – Aerial Photograph 2. The existing site is comprised of undeveloped land with natural grasses and vegetation. The southern boundary of the site contains a watermain and overhead electric lines. 3. The majority of the site slopes to the alley and Red Cedar Circle, while gently slopes to the south. The site generally is very flat except along the eastern boundary. 4. A Web Soil Survey from the Natural Resources Conservation Service lists the soils for the area as Hydrologic Soil Group C and have a low infiltration rate. Schrader Propane Offices Preliminary Drainage Report 3 5. The proposed project site plan is composed of 1 commercial building, four detention ponds, concrete parking, concrete drives, and gravel yard/parking. This site will employ water quality features and runoff reduction facilities including rain gardens, pervious pavers and extended detention basins. Figure 2– Proposed Site Plan 6. No existing irrigation facilities are known at this time. 7. The project site is within the Evergreen Park Subdivision Drainage Plan and the NECCO drainage basin. The proposed project is not requesting a change in the land use. C. Floodplain 1. The subject property is not located in a FEMA or City regulatory floodplain. Schrader Propane Offices Preliminary Drainage Report 4 Figure 3 – Existing Floodplains II. DRAINAGE BASINS AND SUB-BASINS A. Major Basin Description 1. The Schrader project is located within the Dry Creek Master Drainage Basin. B. Sub-Basin Description 1. The existing western half of the property generally drains to the western alley. From there, flows are conveyed along the alley to Conifer Street and to existing downstream inlets. 2. The existing eastern half of the site generally drains to Red Cedar Circle. From there, the flows are conveyed along the street curb and gutter to Conifer Street and to existing downstream inlets. 3. The proposed plan will generally detain developed flows and release to the Red Cedar Circle curbline. Schrader Propane Offices Preliminary Drainage Report 5 III. DRAINAGE DESIGN CRITERIA A. Regulations This project is requesting an increased release rate greater than the historic 2-yr. The detention ponds are proposed to release into the existing street curbline. To create detention on-site, the site driveway was built up in order to detain above the existing curbline. As such, runoff from the proposed driveway was unable to be completely detained and released at the 2-yr historic rate. A small pond is proposed to attenuate the majority of the driveway flows. B. Four Step Process The overall stormwater management strategy employed with Schrader Propane Offices project utilizes the “Four Step Process” to minimize adverse impacts of urbanization on receiving waters. The following is a description of how the proposed development has incorporated each step. Step 1 – Employ Runoff Reduction Practices Specific techniques have been utilized with the proposed development to facilitate the reduction of runoff peaks, volumes, and pollutant loads as the site is developed from the current use by implementing multiple Low Impact Development (LID) strategies including: Routing flows, to the extent feasible, through StormTech Isolator chambers to remove sediment migration. Providing on-site detention to increase time of concentration, promote infiltration and reduce loads on existing storm infrastructure. Providing gravel parking area in the western portion of the site to reduce the overall impervious area and to minimize directly connected impervious areas (MDCIA). Step 2 – Implement BMPs That Provide a Water Quality Capture Volume (WQCV) with Slow Release The efforts taken in Step 1 will facilitate the reduction of runoff; however, this development will still generate stormwater runoff that will require additional BMPs and water quality. The LID strategies listed above will provide the water quality treatment required for this project. Additional water quality for this site is provided by the NECCO drainage project within the downstream extended detention ponds. Step 3 – Stabilize Drainageways There are no major drainageways within the subject property. This property discharges to existing curb and gutter. Step 4 – Implement Site Specific and Other Source Control BMPs. The proposed project will improve upon site specific source controls compared to historic conditions: Localized trash enclosures within the development will allow for the disposal of solid waste. Stormtech Underground Chambers for water treatment prior to flows entering the extended detention basins. Water Quality measures to protect and prolong the design life of the BMPs delineated in Step 1. Schrader Propane Offices Preliminary Drainage Report 6 C. Development Criteria Reference and Constraints 1. The proposed site is a part of the NECCO project. This project requires this site to discharge runoff from the 100-yr storm event at the historic 2-year release rate. 2. This site is subject to the LID requirements per the City of Fort Collins. Please see the LID Exhibit located in the Appendix for calculations concerning LID treatment. The site must either have the following: 75% of total new impervious areas must be treated through an LID (Low Impact Development) treatment BMP, or 50% of total new impervious areas must be treated through an LID (Low Impact Development) treatment BMP and 25% of new pavement shall be pervious. D. Hydrological Criteria 1. The City of Fort Collins Rainfall Intensity-Duration-Frequency Curves, as depicted in Figure RA-16 of the FCSCM, serve as the source for all hydrologic computations associated with the development. Tabulated data contained in Table RA-7 has been utilized for Rational Method runoff calculations. 2. The Rational Method has been employed to compute stormwater runoff utilizing coefficients contained in Tables RO-11 and RO-12 of the FCSCM. 3. EPA SWMM modeling was utilized for detention storage calculations and maximum release from the site during a 100-yr event. 4. Three separate design storms have been utilized to address distinct drainage scenarios. The first event analyzed is the “Minor,” or “Initial” Storm, which has a 2- year recurrence interval. The second event considered is the “Major Storm,” which has a 100-year recurrence interval. The third storm computed, for comparison purposes only, is the 10-year event. 5. No other assumptions or calculation methods have been used with this development that are not referenced by current City of Fort Collins criteria. E. Hydraulic Criteria 1. As previously noted, the subject property historically drains to the west and east. 2. All drainage facilities proposed with the Schrader Propane Offices project are designed in accordance with criteria outlined in the FCSCM and/or the Urban Drainage and Flood Control District’s (UDFCD) Urban Storm Drainage Criteria Manual. 3. As stated previously, the subject property is not located within a FEMA regulatory floodplain. 4. The Schrader Propane Offices project does not propose to modify any natural drainageways. F. Floodplain Regulations Compliance 1. As previously mentioned, all structures are located outside of any FEMA 100-year floodplain, and thus are not subject to any floodplain regulations. G. Modifications of Criteria 1. This project is requesting an increased release rate greater than the historic 2-yr. Schrader Propane Offices Preliminary Drainage Report 7 IV. DRAINAGE FACILITY DESIGN A. General Concept 1. The main objectives of the Schrader drainage design are to minimize the developed 100-yr event discharge from the site and meet LID treatment requirements. 2. The site is constrained by a lack of accessible drainage outfall. The site has been designed to store runoff above and release to the existing Red Cedar Circle curb and gutter. 3. A list of tables and figures used within this report can be found in the Table of Contents at the front of the document. The tables and figures are located within the sections to which the content best applies. 4. Historic runoff from Schrader Propane Offices project site was evaluated. This evaluation provided the historic 2-yr, 10-yr, and 100-yr peak runoff rates for the existing site. The 1.06 acre site was evaluated to have a historic 2-yr, 10-yr and 100-yr runoff of 0.29 cfs, 0.50 cfs, and 1.32 cfs, respectively. This is higher than the published 0.20 cfs/acre for the Dry Creek Master Drainage Basin 2-yr historic. 5. The Schrader project is divided the site into five (5) major drainage basins, designated as Basins A, B, C, D and UD. Basin A Basin A is a total of 0.62 acres. Basin A consists of proposed building, concrete drive, gravel parking lot, and detention pond. Runoff from Basin A flows via sheet flow to a drainage pan and captured in proposed inlets. Stormwater from Basin A is detained in the combination of Ponds 1, 2 and 3. Basin A is treated for LID within the underground Stormtech chambers. Total flow during a 100-yr storm from Basin A is calculated at a 4.07 cfs. Basin B Basin B is a total of 0.19 acres. Basin B consists of proposed building, concrete parking lot, concrete drive, curb and gutter, and landscaped areas. Runoff from Basins B sheet flows to a curb and gutter and is collect in proposed inlets. Stormwater from Basin B is detained in the combination of Pond 1, 2 and 3. Total flow during a 100-yr storm from Basin B is calculated at 1.89 cfs. Basin C Basin C is a total of 0.05 acres. Basin C consists of Detention Pond 3. Runoff from Basin C is detained in Detention Pond 3. Total flow during a 100-yr storm from Basin C is calculated at 0.16 cfs. Basin D Basin C is a total of 0.11 acres. Basin D consists of concrete drive, proposed building, curb and gutter and detention Pond 4. Runoff from Basin D sheet flows to a trench drain and is conveyed to Detention Pond 4. Runoff from Basin D is detained in Detention Pond 4. Total flow during a 100-yr storm from Basin D is calculated at 1.02 Schrader Propane Offices Preliminary Drainage Report 8 Basin UD Basin UD1 is a total of 0.06 acres. Basin UD1 consists of concrete drive, sidewalk and landscaping. Due to the constrained outfall location, the site required to be graded up from Red Cedar Circle. This area was unable to be captured on-site and conveyed to the proposed detention ponds. This basin is not detained and runoff will continue to flow to historic capture points. Total flow during a 100-yr storm from Basin UD1 is calculated at 0.19 cfs. Basin UD2 is a total of 0.03 acres. Basin UD2 consists of tie-in grading to existing ground. This basin is not detained and runoff will continue to flow to historic capture points. Total flow during a 100-yr storm from Basin UD2 is calculated at 0.06 cfs. 6. Four (4) detention ponds are proposed with the Schrader Propane Offices project. Detention Pond 1 is located within Basin A. Detention Pond 2 is located within Basin A. Detention Pond 3 is located within Basin C. Detention Pond 4 is located within Basin D. Detention Pond 1, 2 and 3 essentially function as one pond connected by storm sewer and rain garden. Detention Pond 1 will fill up during typical storm events. Detention Pond 1 will back up into Detention Pond 2 and 3 during larger storm events. Detention Pond 1, 2, and 3 Combined Detention Pond 1, 2 and 3 combined has a total of 0.22 ac-ft storage available. 0.18 ac-ft of storage is required with this project. Water quality control volume for Basin A, B and C is not included in the pond volume since water quality has been provided via LID measures upstream. Emergency Overflow from the pond is directed around the parking lot curb return and down the concrete drive to the Red Cedar Circle. Release rate from Pond 1, 2 and 3 is proposed at 0.13 cfs. Detention Pond 4 Detention Pond 4 has a total of 872 cubic feet storage available. 788 cubic feet of storage is required with this project. Water quality control volume for Basin D is not included in the pond volume since water quality has been planned downstream in the NECCO detention ponds. Emergency Overflow from the pond is directed down the concrete drive to the Red Cedar Circle. Due to the grading constraint on-site, the depth within Pond 4 was not enough for the amount of volume required for a 2-yr historic release. The release rate from Detention Pond 4 was increased to fully utilize the pond without spilling. Release rate from Pond 4 is proposed at 0.08 cfs. 7. Total Stormwater Release from Site Rational Method/FAA Calculations 100-yr stormwater release from the site is a combination of release from Detention Pond 1, 2 and 3 Combined (0.13 cfs), Detention Pond 4 (0.08 cfs), Basin UD1 100- yr runoff (0.19 cfs) and Basin UD2 100-yr runoff (0.06 cfs). The total release from the site during a 100-yr event, utilizing the rational method and FAA calculations, would be a total 0.46 cfs. The historic release from the site was calculated at 0.29 cfs. The proposed total release from the site is approximately 0.17 cfs above the historic 2-yr release. This proposed release would fall somewhere between a historic 2-yr and historic 10-yr release. Schrader Propane Offices Preliminary Drainage Report 9 The additional 0.17 cfs release from the site is expected to have no negative impacts on downstream facilities or structures. Runoff reduction provided by the underground water quality chambers would help to mitigate this additional discharge from the site. A full-size copy of the Drainage Exhibit can be found in the Map Pocket at the end of this report. B. Specific Details 1. Additional details to be provided with the FDP submittal. V. CONCLUSIONS A. Compliance with Standards 1. The drainage design proposed with the Schrader Propane Offices project complies with the City of Fort Collins’ Stormwater Criteria Manual. 2. The drainage design proposed with the Schrader Propane Offices complies with the City of Fort Collins’ Master Drainage Plan for the Dry Creek Drainage Basin, with the exception of an increased 100-yr release rate from the site. 3. There are no regulatory floodplains associated with the development. 4. The drainage plan and stormwater management measures proposed with the development are compliant with all applicable State and Federal regulations governing stormwater discharge. 5. The site achieves the requirements set forth by the City of Fort Collins for Low Impact Development (LID) by providing 83% total impervious areas as being treated through an LID treatment. Please see LID Exhibit located in the Appendix. B. Drainage Concept 1. The drainage design proposed with this project will effectively comply with previous studies and will limit any potential damage or erosion associated with its stormwater runoff. All existing downstream drainage facilities are expected to not be impacted negatively by this development 2. The drainage design is anticipated to be very conservative. We have omitted any runoff reduction that will manifest due to infiltration within the underground Stormtech chambers. This is currently unable to be calculated with available soils data. Schrader Propane Offices Preliminary Drainage Report 10 References 1. Fort Collins Stormwater Criteria Manual, City of Fort Collins, Colorado, as adopted by Ordinance No. 174, 2011, and referenced in Section 26-500 (c) of the City of Fort Collins Municipal Code. 2. Master Storm Drainage and Detention Plan for Evergreen Park, Cornell Consulting Company. 3. Larimer County Urban Area Street Standards, Adopted January 2, 2001, Repealed and Reenacted, Effective October 1, 2002, Repealed and Reenacted, Effective April 1, 2007. 4. Soils Resource Report for Larimer County Area, Colorado, Natural Resources Conservation Service, United States Department of Agriculture. 5. Urban Storm Drainage Criteria Manual, Volumes 1-3, Urban Drainage and Flood Control District, Wright-McLaughlin Engineers, Denver, Colorado, Revised April 2008. APPENDIX A HYDROLOGIC COMPUTATIONS Schrader CHARACTER OF SURFACE 1 : Runoff Coefficient Percentage Impervious Project: Schrader Streets, Parking Lots, Roofs, Alleys, and Drives: Calculations By: S. Thomas Asphalt ……....……………...……….....…...……………….………………………………………………………….. 0.95 100% Date: June 27, 2016 Concrete …….......……………….….……….………………..….…………………………………………………….. 0.95 90% Gravel (packed) ……….…………………….….…………………………..………………………………………….. 0.50 40% Roofs …….…….………………..……………….……………………………………………………………………… 0.95 90% Pavers…………………………...………………..……………………………………………………………………… 0.40 40% Lawns and Landscaping Sandy Soil Flat <2% ……………………………………………………………………………………………………………… 0.10 0% Average 2% to 7% ………………………………………………………………………………………………….. 0.15 0% Steep >7% …………………………………………………………………………………………………………… 0.20 0% Clayey Soil Flat <2% ……………………………………………………………………………………………………………… 0.20 0% Average 2% to 7% ………………………………………………………………………………………………….. 0.25 0% Steep >7% …………………………………………………………………………………………………………… 0.35 0% 2-year Cf = 1.00 10-year Cf = 1.00 100-year C f = 1.25 Runoff Coefficients are taken from the Fort Collins Stormwater Criteria Manual, Table RO-11 Sub-Basin ID Sub- BasinBasin Area (ac) Area of Gravel (ac) Area of Concrete Pavement (ac) Area of Concrete (ac) Area of Pavers (ac) Area of Roofs (ac) Soil Type and Average Slope Area of Lawns and Landscaping (ac) 2-year Composite Runoff Coefficient 10-year Composite Runoff Coefficient Schrader Overland Flow, Time of Concentration: Project: Schrader Calculations By: Gutter/Swale Flow, Time of Concentration: Date: Tt = L / 60V Tc = Ti + Tt (Equation RO-2) Velocity (Gutter Flow), V = 20·S½ Velocity (Swale Flow), V = 15·S½ NOTE: C-value for overland flows over grassy surfaces; C = 0.25 Is Length >500' ? C*Cf (2-yr Cf=1.00) C*Cf (10-yr Cf=1.00) C*Cf (100-yr Cf=1.25) Length, L (ft) Slope, S (%) Ti 2-yr (min) Ti 10-yr (min) Ti 100-yr (min) Length, L (ft) Slope, S (%) Velocity, V (ft/s) Tt (min) 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) 1 HISTORIC No 0.20 0.20 0.25 173 0.58% 26.6 26.6 25.1 0 n/a N/A N/A 26.6 26.6 25.1 * Time of Concentrations are calculated for the entire basin and used for both the Impervious and Pervious portions of the basins. June 27, 2016 EXISTING TIME OF CONCENTRATION COMPUTATIONS Schrader Rational Method Equation: Project: Schrader Calculations By: Date: Rainfall Intensity: 1 HISTORIC 1.06 27 27 25 0.20 0.20 0.25 1.39 2.37 4.98 0.29 0.50 1.32 June 27, 2016 Intensity, i10 (in/hr) C10 Area, A (acres) Intensity, i2 (in/hr) 100-yr Tc (min) EXISTING RUNOFF COMPUTATIONS C100 Design Point Flow, Q100 (cfs) Flow, Q2 (cfs) 10-yr Tc (min) 2-yr Tc (min) C2 Flow, Q10 (cfs) Intensity, i100 (in/hr) Sub-Basin(s) S. Thomas Rainfall Intensity taken from the Fort Collins Stormwater Criteria Manual (FCSCM), Tables RA-7 and RA-8 Q = C f ( C )( i )( A ) 6/27/2016 4:14 PM D:\Projects\146-011\Drainage\Hydrology\146-011_Existing Hydrologic Calculations.xlsx\Runoff Schrader CHARACTER OF SURFACE 1 : Runoff Coefficient Percentage Impervious Project: Schrader Streets, Parking Lots, Roofs, Alleys, and Drives: Calculations By: S. Thomas Asphalt ……....……………...……….....…...……………….………………………………………………………….. 0.95 100% Date: April 3, 2017 Concrete …….......……………….….……….………………..….…………………………………………………….. 0.95 90% Gravel (packed) ……….…………………….….…………………………..………………………………………….. 0.50 40% Roofs …….…….………………..……………….……………………………………………………………………… 0.95 90% Pavers…………………………...………………..……………………………………………………………………… 0.40 40% Lawns and Landscaping Sandy Soil Flat <2% ……………………………………………………………………………………………………………… 0.10 0% Average 2% to 7% ………………………………………………………………………………………………….. 0.15 0% Steep >7% …………………………………………………………………………………………………………… 0.20 0% Clayey Soil Flat <2% ……………………………………………………………………………………………………………… 0.20 0% Average 2% to 7% ………………………………………………………………………………………………….. 0.25 0% Steep >7% …………………………………………………………………………………………………………… 0.35 0% 2-year Cf = 1.00 10-year Cf = 1.00 100-year C f = 1.25 Runoff Coefficients are taken from the Fort Collins Stormwater Criteria Manual, Table RO-11 Sub-Basin ID Sub- BasinBasin Area (ac) Area of Gravel (ac) Area of Concrete Pavement (ac) Area of Concrete (ac) Area of Pavers (ac) Area of Roofs (ac) Soil Type and Average Slope Area of Lawns and Landscaping (ac) 2-year Composite Runoff Coefficient 10-year Composite Runoff Coefficient Schrader Overland Flow, Time of Concentration: Project: Schrader Calculations By: Gutter/Swale Flow, Time of Concentration: Date: Tt = L / 60V Tc = Ti + Tt (Equation RO-2) Velocity (Gutter Flow), V = 20·S½ Velocity (Swale Flow), V = 15·S½ NOTE: C-value for overland flows over grassy surfaces; C = 0.25 Is Length >500' ? C*Cf (2-yr Cf=1.00) C*Cf (10-yr Cf=1.00) C*Cf (100-yr Cf=1.25) Length, L (ft) Slope, S (%) Ti 2-yr (min) Ti 10-yr (min) Ti 100-yr (min) Length, L (ft) Slope, S (%) Velocity, V (ft/s) Tt (min) 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) 1 A1 No 0.55 0.55 0.68 83 1.57% 8.1 8.1 6.1 0 n/a N/A N/A 8.1 8.1 6.1 1 A2 No 0.57 0.57 0.71 83 1.57% 7.8 7.8 5.8 0 n/a N/A N/A 7.8 7.8 5.8 2 B1 No 0.86 0.86 1.00 82 1.22% 3.9 3.9 1.6 31 0.65% 1.61 0.3 5.0 5.0 5.0 2 B2 No 0.93 0.93 1.00 82 1.22% 2.7 2.7 1.6 31 0.65% 1.61 0.3 5.0 5.0 5.0 Schrader Rational Method Equation: Project: Schrader Calculations By: Date: Rainfall Intensity: 1 A1 0.30 8 8 6 0.55 0.55 0.68 2.40 4.10 9.31 0.19 0.39 0.66 1.88 1 A2 0.32 8 8 6 0.57 0.57 0.71 2.46 4.21 9.63 0.22 0.45 0.77 2.19 2 B1 0.05 5 5 5 0.86 0.86 1.00 2.85 4.87 9.95 0.06 0.13 0.22 0.52 2 B2 0.08 5 5 5 0.93 0.93 1.00 2.85 4.87 9.95 0.11 0.21 0.37 0.80 2 B3 0.06 5 5 5 0.95 0.95 1.00 2.85 4.87 9.95 0.08 0.15 0.26 0.57 3 C 0.05 6 6 6 0.24 0.24 0.30 2.67 4.56 9.63 0.02 0.04 0.06 0.16 4 D 0.11 5 5 5 0.75 0.75 0.93 2.85 4.87 9.95 0.12 0.23 0.40 1.02 5 UD1 0.06 19 19 16 0.38 0.38 0.47 1.68 2.86 6.30 0.02 0.04 0.07 0.19 5 UD2 0.03 5 5 5 0.20 0.20 0.25 2.85 4.87 9.95 0.01 0.01 0.03 0.06 Flow, QWQ (cfs) Area, A (acres) Intensity, i2 (in/hr) 100-yr Tc (min) PROPOSED RUNOFF COMPUTATIONS C100 Design Point Flow, Q100 (cfs) Flow, Q2 (cfs) 10-yr Tc (min) 2-yr Tc (min) C2 Flow, Q10 (cfs) Intensity, i100 (in/hr) Sub-Basin(s) S. Thomas Rainfall Intensity taken from the Fort Collins Stormwater Criteria Manual (FCSCM), Tables RA-7 and RA-8 April 3, 2017 Intensity, i10 (in/hr) C10 Q = C f ( C )( i )( A ) 4/3/2017 3:06 PM D:\Projects\146-011\Drainage\Hydrology\146-011_Conceptual Hydrologic Calculations.xlsx\Runoff APPENDIX B HYDRAULIC COMPUTATIONS B.1 DETENTION POND SIZING B.2 STORM SEWER (NOT INCLUDED) B.3 INLET (NOT INCLUDED) APPENDIX B.1 DETENTION PONDS AND WATER QUALITY Schrader 146-011 Fort Collins, Colorado S. Thomas Date: 4/3/2017 Pond No.: Combined Pond 1, 2, and 3 A 100-yr 0.77 Approx. WQCV 0 ft 3 Area (A)= 0.86 acres Quantity Detention 7837 ft 3 (from FAA) Max Release Rate = 0.13 cfs Total Volume 0.18 ac-ft Time Time Ft.Collins 100-yr Intensity Q100 Inflow (Runoff) Volume Outflow (Release) Volume Storage Detention Volume (mins) (secs) (in/hr) (cfs) (ft 3 ) (ft 3 ) (ft 3 ) 5 300 9.95 6.6 1977 39 1938 10 600 7.72 5.1 3067 78 2989 15 900 6.52 4.3 3886 117 3769 20 1200 5.60 3.7 4450 156 4294 25 1500 4.98 3.3 4947 195 4752 30 1800 4.52 3.0 5388 234 5154 35 2100 4.08 2.7 5674 273 5401 40 2400 3.74 2.5 5944 312 5632 45 2700 3.46 2.3 6186 351 5835 50 3000 3.23 2.1 6417 390 6027 55 3300 3.03 2.0 6621 429 6192 60 3600 2.86 1.9 6818 468 6350 65 3900 2.72 1.8 7025 507 6518 70 4200 2.59 1.7 7203 546 6657 75 4500 2.48 1.6 7390 585 6805 80 4800 2.38 1.6 7565 624 6941 85 5100 2.29 1.5 7734 663 7071 90 5400 2.21 1.5 7903 702 7201 95 5700 2.13 1.4 8040 741 7299 100 6000 2.06 1.4 8185 780 7405 105 6300 2.00 1.3 8344 819 7525 110 6600 1.94 1.3 8479 858 7621 115 6900 1.89 1.3 8636 897 7739 120 7200 1.84 1.2 8773 936 7837 Detention Pond Calculation | FAA Method Project Number: Schrader 146-011 Fort Collins Co S. Thomas Date: 4/3/2017 Pond No.: Pond 1, 2 and 3 Combined A 100-yr 0.18 acft 4976.07 ft. Design Storm WQCV Required Volume= 0 ft 3 n/a ft. Contour Elevation (Y- values) Contour Area Depth Column Not Used Incremental Volume Total Volume Total Volume ft 3 ft. ft 3 ft 3 ft 3 acre-feet 4,973.80 4 0.00 0 0 0 0 4,974.00 262 0.20 20 20 0.00 4,974.20 857 0.20 106 126 0.00 4,974.40 1309 0.20 215 341 0.01 4,974.60 1449 0.20 275 616 0.01 4,974.80 1546 0.20 299 915 0.02 4,975.00 1642 0.20 318 1234 0.03 4,975.20 1739 0.20 338 1571 0.04 4,975.40 3262 0.20 492 2063 0.05 4,975.60 6040 0.20 915 2978 0.07 4,975.80 9358 0.20 1526 4504 0.10 4,976.00 13065 0.20 2230 6734 0.15 4,976.20 16475 0.20 2945 9679 0.22 Design Point Design Storm Require Volume= Stage - Storage Calculation Project Number: Project Location: Calculations By: Required Volume Water Surface Elevation (WSE) Schrader 146-011 Fort Collins, Colorado S. Thomas Date: 4/3/2017 Pond No.: Pond 4 D 100-yr 0.93 Approx. WQCV 0 ft3 Area (A)= 0.11 acres Quantity Detention 789 ft3 (from FAA) Max Release Rate = 0.08 cfs Total Volume 0.02 ac-ft Time Time Ft.Collins 100-yr Intensity Q100 Inflow (Runoff) Volume Outflow (Release) Volume Storage Detention Volume (mins) (secs) (in/hr) (cfs) (ft3) (ft3) (ft3) 5 300 9.95 1.0 305 24 281 10 600 7.72 0.8 474 48 426 15 900 6.52 0.7 600 72 528 20 1200 5.60 0.6 687 96 591 25 1500 4.98 0.5 764 120 644 30 1800 4.52 0.5 832 144 688 35 2100 4.08 0.4 877 168 709 40 2400 3.74 0.4 918 192 726 45 2700 3.46 0.4 956 216 740 50 3000 3.23 0.3 991 240 751 55 3300 3.03 0.3 1023 264 759 60 3600 2.86 0.3 1053 288 765 65 3900 2.72 0.3 1085 312 773 70 4200 2.59 0.3 1113 336 777 75 4500 2.48 0.3 1142 360 782 80 4800 2.38 0.2 1169 384 785 85 5100 2.29 0.2 1195 408 787 90 5400 2.21 0.2 1221 432 789 95 5700 2.13 0.2 1242 456 786 100 6000 2.06 0.2 1264 480 784 105 6300 2.00 0.2 1289 504 785 110 6600 1.94 0.2 1310 528 782 115 6900 1.89 0.2 1334 552 782 120 7200 1.84 0.2 1355 576 779 Detention Pond Calculation | FAA Method Project Number: Project Location: Calculations By: Input Variables Results Design Point Design Storm Required Detention Volume Developed "C" = 4/3/2017 3:04 PM D:\Projects\146-011\Drainage\Detention\146-011_Conceptual Detention Pond 4.xlsx\FAA_CoFC idf_Pond 1 Schrader 146-011 Fort Collins Co S. Thomas Date: 4/3/2017 Pond No.: Pond 4 D 100-yr 788.85 ft 3 4975.13 ft. Design Storm WQCV Required Volume= 0 ft 3 n/a ft. Contour Elevation (Y- values) Contour Area Depth Column Not Used Incremental Volume Total Volume Total Volume ft 3 ft. ft 3 ft 3 ft 3 acre-feet 4,974.20 190 0.00 0 0 0 0 4,974.40 529 0.20 69 69 0.00 4,974.60 833 0.20 135 204 0.00 4,974.80 1062 0.20 189 393 0.01 4,975.00 1210 0.20 227 620 0.01 4,975.20 1317 0.20 252 872 0.02 Design Point Design Storm Require Volume= Stage - Storage Calculation Project Number: Project Location: Calculations By: Required Volume Water Surface Elevation (WSE) 1008 Project Title Date: Project Number Calcs By: Client Basins 0.8 WQCV = Watershed inches of Runoff (inches) 46.00% a = Runoff Volume Reduction (constant) i = Total imperviousness Ratio (i = Iwq/100) 0.156 in A = 0.62 ac V = 0.0081 ac-ft V = Water Quality Design Volume (ac-ft) WQCV = Water Quality Capture Volume (inches) A = Watershed Area (acres) 352 cu. ft. Drain Time a = i = WQCV = Figure EDB-2 - Water Quality Capture Volume (WQCV), 80th Percentile Runoff Event Schrader Propane Offices February 22, 2017 146-011 S. Thomas Basin A1-A2 0.231 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 WQCV (watershed inches) Total Imperviousness Ratio (i = Iwq/100) Water Quality Capture Volume 6 hr 12 hr 24 hr 40 hr WQCV = a ( 0.91 i 3 - 1 . 19 i 2 + 0 . 78 i ) WQCV = a ( 0.91 i 3 - 1 . 19 i 2 + 0 . 78 i ) V * A 12 WQCV ÷ ø Pond No : Basin A WQ 0.69 5.00 min 291 ft3 0.62 acres 0.01 ac-ft Max Release Rate = 0.20 cfs Time (min) Ft Collins WQ Intensity (in/hr) Inflow Volume (ft3) Outflow Adjustment Factor Qav (cfs) Outflow Volume (ft3) Storage Volume (ft3) 5 1.425 183 1.00 0.20 60 123 10 1.105 284 1.00 0.20 120 164 15 0.935 360 0.67 0.13 120 240 20 0.805 413 0.63 0.13 150 263 25 0.715 459 0.60 0.12 180 279 30 0.650 501 0.58 0.12 210 291 35 0.585 526 0.57 0.11 240 286 40 0.535 549 0.56 0.11 270 279 45 0.495 572 0.56 0.11 300 272 50 0.460 590 0.55 0.11 330 260 55 0.435 614 0.55 0.11 360 254 60 0.410 631 0.54 0.11 390 241 65 0.385 642 0.54 0.11 420 222 70 0.365 656 0.54 0.11 450 206 75 0.345 664 0.53 0.11 480 184 80 0.330 678 0.53 0.11 510 168 85 0.315 687 0.53 0.11 540 147 90 0.305 705 0.53 0.11 570 135 95 0.290 707 0.53 0.11 600 107 100 0.280 719 0.53 0.11 630 89 105 0.270 728 0.52 0.10 660 68 110 0.260 734 0.52 0.10 690 44 115 0.255 753 0.52 0.10 720 33 120 0.245 755 0.52 0.10 750 5 *Note: Using the method described in Urban Storm Drainage Criteria Manual Volume 2. A = Tc = Project Location : Design Point C = Design Storm STORM TECH CALCULATION; MODIFIED FAA METHOD w/ Ft Collins IDF Input Variables Results Required Detention Volume Fort Collins, Colorado 146-011 Schrader Propane Offices Project Number : Vault ID Total Required WQ Volume (cf) Flow, WQ (cfs) Chamber Type Chamber Release Ratea (cfs) Chamber Volumeb (cf) Installed Chamber w/ Aggregatec (cf) Mimimum No. of Chambersd Total Release Ratee (cfs) Required Storage Volume by FAA Method (cf) Mimimum No. of Chambersf Storage Provided within the Chambersg (cf) Total Installed System Volumeh (cf) Basin A1, A2 352 0.42 SC-160 0.016 14.70 29.30 13 0.20 291 10 147 381 SC-740 a. Release rate per chamber, limited by flow through geotextile with accumulated sediment. b. Volume within chamber only, not accounting for void spaces in surrounding aggregate. c. Volume includes chamber and void spaces (40%) in surrounding aggregate, per chamber unit. d. Number of chambers required to provide full WQCV within total installed system, including aggregate. e. Release rate per chamber times number of chambers. f. Number of chambers required to provide required FAA storage volume stored within the chamber only (no aggregate storage). g. Volume provided in chambers only (no aggregate storage). This number must meet or exceed the required FAA storage volume. h. System volume includes total number of chambers, plus surrounding aggregate. This number must meet or exceed the required WQCV. Chamber Configuration Summary D:\Projects\146-011\Drainage\WatQual\Basin A WQ Chambers.xlsx 1008 Project Title Date: Project Number Calcs By: Client Basins 0.8 WQCV = Watershed inches of Runoff (inches) 86.00% a = Runoff Volume Reduction (constant) i = Total imperviousness Ratio (i = Iwq/100) 0.296 in A = 0.19 ac V = 0.0047 ac-ft V = Water Quality Design Volume (ac-ft) WQCV = Water Quality Capture Volume (inches) A = Watershed Area (acres) 204 cu. ft. Drain Time a = i = WQCV = Figure EDB-2 - Water Quality Capture Volume (WQCV), 80th Percentile Runoff Event Schrader Propane Offices February 22, 2017 146-011 S. Thomas Basin B1-B3 0.231 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 WQCV (watershed inches) Total Imperviousness Ratio (i = Iwq/100) Water Quality Capture Volume 6 hr 12 hr 24 hr 40 hr WQCV = a ( 0.91 i 3 - 1 . 19 i 2 + 0 . 78 i ) WQCV = a ( 0.91 i 3 - 1 . 19 i 2 + 0 . 78 i ) V * A 12 WQCV ÷ ø Pond No : Basin B WQ 1.00 5.00 min 117 ft3 0.19 acres 0.00 ac-ft Max Release Rate = 0.10 cfs Time (min) Ft Collins WQ Intensity (in/hr) Inflow Volume (ft3) Outflow Adjustment Factor Qav (cfs) Outflow Volume (ft3) Storage Volume (ft3) 5 1.425 81 1.00 0.10 30 51 10 1.105 126 1.00 0.10 60 66 15 0.935 160 0.67 0.07 60 100 20 0.805 184 0.63 0.06 75 109 25 0.715 204 0.60 0.06 90 114 30 0.650 222 0.58 0.06 105 117 35 0.585 233 0.57 0.06 120 113 40 0.535 244 0.56 0.06 135 109 45 0.495 254 0.56 0.06 150 104 50 0.460 262 0.55 0.06 165 97 55 0.435 273 0.55 0.05 180 93 60 0.410 280 0.54 0.05 195 85 65 0.385 285 0.54 0.05 210 75 70 0.365 291 0.54 0.05 225 66 75 0.345 295 0.53 0.05 240 55 80 0.330 301 0.53 0.05 255 46 85 0.315 305 0.53 0.05 270 35 90 0.305 313 0.53 0.05 285 28 95 0.290 314 0.53 0.05 300 14 100 0.280 319 0.53 0.05 315 4 105 0.270 323 0.52 0.05 330 -7 110 0.260 326 0.52 0.05 345 -19 115 0.255 334 0.52 0.05 360 -26 120 0.245 335 0.52 0.05 375 -40 *Note: Using the method described in Urban Storm Drainage Criteria Manual Volume 2. A = Tc = Project Location : Design Point C = Design Storm STORM TECH CALCULATION; MODIFIED FAA METHOD w/ Ft Collins IDF Input Variables Results Required Detention Volume Fort Collins, Colorado 146-011 Schrader Propane Offices Project Number : Vault ID Total Required WQ Volume (cf) Flow, WQ (cfs) Chamber Type Chamber Release Ratea (cfs) Chamber Volumeb (cf) Installed Chamber w/ Aggregatec (cf) Mimimum No. of Chambersd Total Release Ratee (cfs) Required Storage Volume by FAA Method (cf) Mimimum No. of Chambersf Storage Provided within the Chambersg (cf) Total Installed System Volumeh (cf) Basin B1-B3 204 0.50 SC-160 0.016 14.70 29.30 7 0.11 117 5 74 205 SC-740 a. Release rate per chamber, limited by flow through geotextile with accumulated sediment. b. Volume within chamber only, not accounting for void spaces in surrounding aggregate. c. Volume includes chamber and void spaces (40%) in surrounding aggregate, per chamber unit. d. Number of chambers required to provide full WQCV within total installed system, including aggregate. e. Release rate per chamber times number of chambers. f. Number of chambers required to provide required FAA storage volume stored within the chamber only (no aggregate storage). g. Volume provided in chambers only (no aggregate storage). This number must meet or exceed the required FAA storage volume. h. System volume includes total number of chambers, plus surrounding aggregate. This number must meet or exceed the required WQCV. Chamber Configuration Summary D:\Projects\146-011\Drainage\WatQual\Basin B WQ Chambers.xlsx APPENDIX B.2 STORM SEWERS APPENDIX B.3 INLETS APPENDIX C EROSION CONTROL REPORT Schrader Propane Offices Preliminary Erosion Control Report A comprehensive Erosion and Sediment Control Plan (along with associated details) will be included with the final construction drawings. It should be noted, however, that any such Erosion and Sediment Control Plan serves only as a general guide to the Contractor. Staging and/or phasing of the BMPs depicted, and additional or different BMPs from those included may be necessary during construction, or as required by the authorities having jurisdiction. It shall be the responsibility of the Contractor to ensure erosion control measures are properly maintained and followed. The Erosion and Sediment Control Plan is intended to be a living document, constantly adapting to site conditions and needs. The Contractor shall update the location of BMPs as they are installed, removed or modified in conjunction with construction activities. It is imperative to appropriately reflect the current site conditions at all times. The Erosion and Sediment Control Plan shall address both temporary measures to be implemented during construction, as well as permanent erosion control protection. Best Management Practices from the Volume 3, Chapter 7 – Construction BMPs will be utilized. Measures may include, but are not limited to, silt fencing along the disturbed perimeter, gutter protection in the adjacent roadways and inlet protection at existing and proposed storm inlets. Vehicle tracking control pads, spill containment and clean-up procedures, designated concrete washout areas, dumpsters, and job site restrooms shall also be provided by the Contractor. Grading and Erosion Control Notes can be found on Sheet CS2 of the Utility Plans. The Utility Plans at final design will also contain a full-size Erosion Control Plan as well as a separate sheet dedicated to Erosion Control Details. In addition to this report and the referenced plan sheets, the Contractor shall be aware of, and adhere to, the applicable requirements outlined in any existing Development Agreement(s) of record, as well as the Development Agreement, to be recorded prior to issuance of the Development Construction Permit. Also, the Site Contractor for this project will be required to secure a Stormwater Construction General Permit from the Colorado Department of Public Health and Environment (CDPHE), Water Quality Control Division – Stormwater Program, before commencing any earth disturbing activities. Prior to securing said permit, the Site Contractor shall develop a comprehensive StormWater Management Plan (SWMP) pursuant to CDPHE requirements and guidelines. The SWMP will further describe and document the ongoing activities, inspections, and maintenance of construction BMPs. APPENDIX D LID EXHIBIT Project: Schrader Calculations By: Date: LID BASIN NODE Basin(s) Area, A (sf) Percent Impervious Impervious Area, A (sf) LID1 Basin A 26,921 46% 12,327 Basin B 8,290 86% 7,125 Total Treated 35,211 55% 19,452 LID BASIN NODE Basin(s) Area, A (sf) Percent Impervious Impervious Area, A (sf) LID2 C 2,383 5% 123 D 4,804 65% 3,146 UD1 2,781 21% 586 UD2 1,137 0% 0 Total Proposed Untreated 11,105 35% 3,856 352 381 Basin B WQCV (ft3) 204 205 46,316 23,307 17,481 19,452 83% Total Treated Impervious Area (sf) Percent Impervious Treated by LID measures Basin B Stormtech Chamber Volume (ft3) Total Site Area (sf) Total Proposed Impervious Area (sf) LID TREATMENT SUMMARY Stormtech Chambers - Basin LID1 Basin A WQCV (ft3) Basin A Stormtech Chamber Volume (ft3) 75% Required Minimum Area to be Treated by LID PROPOSED LID UNTREATED AREA S. Thomas April 3, 2017 PROPOSED LID TREATED AREA PROPOSED LID COMPUTATIONS APPENDIX E REFERENCES Hydrologic Soil Group—Larimer County Area, Colorado (Schrader Propane Offices) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/6/2016 Page 1 of 4 4494830 4494840 4494850 4494860 4494870 4494880 4494890 4494900 4494910 4494830 4494840 4494850 4494860 4494870 4494880 4494890 4494900 4494910 493580 493590 493600 493610 493620 493630 493640 493650 493660 493670 493680 493690 493700 493580 493590 493600 493610 493620 493630 493640 493650 493660 493670 493680 493690 493700 40° 36' 18'' N 105° 4' 33'' W 40° 36' 18'' N 105° 4' 27'' W 40° 36' 15'' N 105° 4' 33'' W 40° 36' 15'' N 105° 4' 27'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 25 50 100 150 Feet 0 5 10 20 30 Meters Map Scale: 1:608 if printed on A landscape (11" x 8.5") sheet. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A A/D B B/D C C/D D Not rated or not available Soil Rating Points A A/D B B/D C C/D D Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: http://websoilsurvey.nrcs.usda.gov Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Hydrologic Soil Group Hydrologic Soil Group— Summary by Map Unit — Larimer County Area, Colorado (CO644) Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 73 Nunn clay loam, 0 to 1 percent slopes C 1.6 100.0% Totals for Area of Interest 1.6 100.0% Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Hydrologic Soil Group—Larimer County Area, Colorado Schrader Propane Offices Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/6/2016 Page 3 of 4 Tie-break Rule: Higher Hydrologic Soil Group—Larimer County Area, Colorado Schrader Propane Offices Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/6/2016 Page 4 of 4 MAP POCKET DR1 – OVERALL DRAINAGE EXHIBIT W W W W W W W W W W W W W W W X X X X X X X X X X X X X X X X X X X X X X T T E E E E E E E E E E E E W W W W W W W W W W W W W W W W E E E E E E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV T T T T T T T T T T T T T T SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OH E OHE OHE OHE OHE OHE OHE OHE OHE S W EXISTING RIGHT OF WAY DETENTION POND 1 100-YR WSEL: 4976.07 RED CEDAR CIRCLE (60' ROW) EXISTING 75' TRANSMISSION EASEMENT ALLEY (20' WIDE ASPHALT) N:137303.74 E:195116.70 FND NAIL AND BRASS TAG, LS 14823 N:137542.86 E:195119.39 FND NAIL AND BRASS TAG, LS 14823 PROPOSED 3' ROW TO BE DEDICATED TO THE CITY PROPOSED 9' PROPOSEDEASEMENT 8' UTILITY UTILITY EASEMENT ZERO CURB WITH APRON RUNDOWN VERTICAL CATCH CURB RETAINING WALL 2.5' HEIGHT MAX TRENCH DRAIN 2' DRAINAGE PAN DETENTION POND OUTFALL TO PROPOSEDCURBLINE OUTLET STRUCTURE DETENTION POND OUTFALL TO CURBLINE WITH SIDEWALK CHASE PROPOSED STORM SEWER PROPOSED STORM SEWER STORM JUNCTION AND WATER QUALITY WEIR PROPOSED AREA INLET PROPOSED AREA INLET STORMTECH UNDERGROUND WATER QUALITY CHAMBERS STORM JUNCTION AND WATER QUALITY WEIR DETENTION POND 2 100-YR WSEL: 4976.07 PROPOSED INLET PROPOSED INLET RETAINING WALL 1' HEIGHT MAX 3 2 B1 C UD1 UD2 A1 B2 A2 B3 D 1 PROPOSED INLET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R CityDate Engineer Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 DR1 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's R CityDate Engineer Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROPERTY BOUNDARY EXISTING STORM SEWER 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR SCHRADER PROPANE OFFICES BY NORTHERN ENGINEERING, DATED April 11, 2017 FOR ADDITIONAL INFORMATION. NOTES: FLOW PATH DRAINAGE BASIN BUBBLE A DESIGN POINT A BASIN BOUNDARY PROPOSED STORM SEWER FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) 1 A1 0.30 0.55 0.68 8.1 6.1 0.39 1.88 1 A2 0.32 0.57 0.71 7.8 5.8 0.45 2.19 2 B1 0.05 0.86 1.00 5.0 5.0 0.13 0.52 2 B2 0.08 0.93 1.00 5.0 5.0 0.21 0.80 2 B3 0.06 0.95 1.00 5.0 5.0 0.15 0.57 3 C 0.05 0.24 0.30 6.3 5.9 0.04 0.16 4 D 0.11 0.75 0.93 5.0 5.0 0.23 1.02 5 UD1 0.06 0.38 0.47 18.7 16.4 0.04 0.19 5 UD2 0.03 0.20 0.25 5.0 5.0 0.01 0.06 Detention Pond Summary | Proposed Condition Pond 100-yr Volume (feet cubed) 100-yr WSEL WQCV (ft3) WQCV WSEL Max Release (cfs) 1, 2, 3 Combined 7837.00 4976.07 n/a n/a 0.13 4 788.00 4975.13 n/a n/a 0.08 Survey Area Data: Version 10, Sep 22, 2015 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 22, 2011—Apr 28, 2011 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group—Larimer County Area, Colorado (Schrader Propane Offices) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/6/2016 Page 2 of 4 Project Name : Basin B1-B3 Page 1 of 1 Basin B WQ Chambers.xlsx ö ç è = æ 12 hr Project Name : Basin A1-A2 Page 1 of 1 Basin A WQ Chambers.xlsx ö ç è = æ 12 hr Project Location: Calculations By: Input Variables Results Design Point Design Storm Required Detention Volume Developed "C" = 4/3/2017 3:03 PM D:\Projects\146-011\Drainage\Detention\146-011_Conceptual Detention Pond 1 and 2.xlsx\FAA_CoFC idf_Pond 1 2 B3 No 0.95 0.95 1.00 62 1.61% 1.9 1.9 1.3 83 0.66% 1.63 0.8 5.0 5.0 5.0 3 C No 0.24 0.24 0.30 42 5.95% 5.7 5.7 5.3 65 0.77% 1.75 0.6 6.3 6.3 5.9 4 D No 0.75 0.75 0.93 62 2.02% 4.1 4.1 2.0 30 4.17% 4.08 0.1 5.0 5.0 5.0 5 UD1 No 0.38 0.38 0.47 200 1.25% 17.8 17.8 15.5 130 1.38% 2.35 0.9 18.7 18.7 16.4 5 UD2 No 0.20 0.20 0.25 10 25.00% 1.8 1.8 1.7 0 n/a N/A N/A 5.0 5.0 5.0 * Time of Concentrations are calculated for the entire basin and used for both the Impervious and Pervious portions of the basins. April 3, 2017 PROPOSED TIME OF CONCENTRATION COMPUTATIONS S. Thomas Design Point Sub-Basin Overland Flow Gutter/Pipe Flow Time of Concentration (Equation RO-4) ( ) 3 1 1 . 87 1 . 1 * S Ti C Cf L - = 4/3/2017 3:06 PM D:\Projects\146-011\Drainage\Hydrology\146-011_Conceptual Hydrologic Calculations.xlsx\Tc 100-year Composite Runoff Coefficient Composite % Imperv. A1 0.30 0.23 0.02 0.00 0.00 0.02 Clayey | Flat <2% 0.022 0.55 0.55 0.68 45% A2 0.32 0.25 0.00 0.03 0.00 0.03 Clayey | Flat <2% 0.017 0.57 0.57 0.71 47% B1 0.05 0.00 0.03 0.00 0.00 0.01 Clayey | Flat <2% 0.007 0.86 0.86 1.00 79% B2 0.08 0.00 0.04 0.02 0.00 0.03 Clayey | Flat <2% 0.002 0.93 0.93 1.00 88% B3 0.06 0.00 0.04 0.00 0.00 0.02 Clayey | Flat <2% 0.000 0.95 0.95 1.00 90% C 0.05 0.00 0.00 0.00 0.00 0.00 Clayey | Flat <2% 0.052 0.24 0.24 0.30 5% D 0.11 0.00 0.05 0.03 0.00 0.00 Clayey | Flat <2% 0.030 0.75 0.75 0.93 65% UD1 0.06 0.00 0.01 0.00 0.00 0.00 Clayey | Flat <2% 0.049 0.38 0.38 0.47 21% UD2 0.03 0.00 0.00 0.00 0.00 0.00 Clayey | Flat <2% 0.026 0.20 0.20 0.25 0% Basin A 0.62 0.48 0.02 0.04 0.00 0.04 Clayey | Flat <2% 0.039 0.56 0.56 0.69 46% Basin B 0.19 0.00 0.11 0.02 0.00 0.05 Clayey | Flat <2% 0.009 0.92 0.92 1.00 86% Basin A, B, C 0.86 0.48 0.13 0.06 0.00 0.09 Clayey | Flat <2% 0.099 0.62 0.62 0.77 52% Total 1.06 0.48 0.20 0.09 0.00 0.09 Clayey | Flat <2% 0.204 0.60 0.60 0.76 50% Composite Runoff Coefficient with Adjustment PROPOSED COMPOSITE % IMPERVIOUSNESS AND RUNOFF COEFFICIENT CALCULATIONS 4/3/2017 3:05 PM D:\Projects\146-011\Drainage\Hydrology\146-011_Conceptual Hydrologic Calculations.xlsx\Composite C S. Thomas Design Point Sub-Basin Overland Flow Gutter/Pipe Flow Time of Concentration (Equation RO-4) ( ) 3 1 1 . 87 1 . 1 * S Ti C Cf L - = 6/27/2016 4:14 PM D:\Projects\146-011\Drainage\Hydrology\146-011_Existing Hydrologic Calculations.xlsx\Tc 100-year Composite Runoff Coefficient Composite % Imperv. HISTORIC 1.06 0.00 0.00 0.00 0.00 0.00 Clayey | Flat <2% 1.063 0.20 0.20 0.25 0% Composite Runoff Coefficient with Adjustment EXISTING COMPOSITE % IMPERVIOUSNESS AND RUNOFF COEFFICIENT CALCULATIONS 6/27/2016 4:14 PM D:\Projects\146-011\Drainage\Hydrology\146-011_Existing Hydrologic Calculations.xlsx\Composite C