HomeMy WebLinkAboutReports - Drainage - 03/01/2017DRAINAGE REPORT
FOR
Faith Family
317-321 Sherwood Street
Fort Collins, CO 80521
Prepared for:
Kenny Lee Architecture Group Inc.
209 E 4th Street
Loveland, CO 80537
Prepared by:
www.quality-engineering.com
2637 Midpoint Drive, Suite E
Fort Collins, Colorado 80524
(970) 416-7891
QE Project No: 7040-007
Date: March 2017
Faith Family
FINAL DRAINAGE REPORT
ENGINEER’S CERTIFICATION
I hereby certify that this Final Drainage Report for the design of stormwater management
facilities for the Faith Family Project was prepared by me, or under my direct supervision, in
accordance with the provisions of the City of Fort Collins Storm Drainage Design Criteria and
Construction Standards for the owners thereof.
Cody Geisendorfer, P.E.
Registered Professional Engineer
State of Colorado No. 41326
I. Table of Contents
I. GENERAL LOCATION AND DESCRIPTION....................................... 1
A. Location .................................................................................................................1
B. Description of Property ........................................................................................1
II. DRAINAGE BASINS AND SUB-BASINS ................................................ 2
A. Major Basin Description .......................................................................................2
B. Sub-Basin Description ..........................................................................................2
III. DRAINAGE CRITERIA ............................................................................ 3
A. Regulations ............................................................................................................3
B. Implementation of the “Four Step Process” ........................................................3
C. Development Criteria Reference and Constraints ...............................................4
D. Hydrological Criteria ............................................................................................4
E. Hydraulic Criteria ................................................................................................5
F. Modifications of Criteria ......................................................................................5
IV. DRAINAGE FACILITY DESIGN ............................................................ 5
A. General Concept ...................................................................................................5
B. Specific Details ......................................................................................................5
V. CONCLUSIONS ......................................................................................... 6
A. Compliance with Standards..................................................................................6
B. Drainage Concept .................................................................................................6
VI. REFERENCES ........................................................................................... 7
VII. APPENDICES
A. Hydrologic Computations
Vicinity Map
Fort Collins Flood Map
FEMA Firm Panel 08069C0979H
USGS Soil Map
Fort Collins Rainfall Intensity Curve
Fort Collins Rainfall Intensity Table
Table RO-3 Recommended Percentage Imperviousness Values
Rational Method Calculated Composite C Tables
Rational Method Calculated Imperviousness
Rational Method Calculated Flows
B. Hydraulic Computations
Fort Collins Modified FFA Method
Underground Detention Calculation
Infiltration Calculation
C. Map Pocket
Drainage Plan
I. GENERAL LOCATION AND DESCRIPTION
A. Location
The proposed site is located in the southeast quarter (NE ¼) of Section 11, Township 7
North, Range 69 West of the 6th P.M. in Larimer County, Colorado. Specifically, the
property is located on Sherwood Street between Magnolia Street and Olive Street. The
property address is 317-321 Sherwood Street, Fort Collins, Colorado, 80521. (Please see
the vicinity map located in the Appendix A).
B. Description of Property
The property’s parcel number are 9711420904 and 9711420903. The site is located on
Lots 3 and 4, Block 73 City of Fort Collins and is currently 0.436 acres of residential land
surrounded by the residential lots to the north and south, an alley to the west, and
Sherwood Street to the east. The site can be accessed from Sherwood Street and the
existing alley. Two gravel patches provide on-site parking and the site can be accessed
from the alley.
The existing property is a residential building with no occupants located in the central
portion of the Old Town Basin. The site drains east to Sherwood Street through a
drainage channel along the northern property line. Sherwood Street drains south to the
existing inlet, where it is conveyed to the Poudre River. Runoff from the alley flows
south to West Magnolia Street, where is flows east to an existing storm inlet. There are
generally no offsite flows that drain toward the property. The site is within the city-
regulated 100-year Old Town floodplain. More specifically, the entire site is located
within the City of Fort Collins Flood Fringe. The City of Fort Collins Floodway
encompasses all of Sherwood Street and West Magnolia Street and extends to the back of
the sidewalk. The site is located with the FEMA Firm Panel 08069C0979H. (see City
Flood Risk Map and the FEMA Firm Panel in Appendix A).
According to the NRCS soils map survey, the native soils consist of Fort Collins Loam,
which is a Type “C” soils. These soils consist chiefly of soils having a layer that impedes
the downward movement of water or soils of moderately fine texture or fine texture.
These soils have a slow rate of water transmission.
There are no irrigation facilities located within the proposed site area.
The existing building will be remodeled to serve as temporary housing for homeless
families. The proposed development will consist of the construction of an off-street
permeable paver parking lot that will act as a parking for the residents and employees of
Faith Family. The permeable paver parking lot will have an underdrain network of 4”
perforated that drains into a 8’ dry well. The existing gravel alley will also be paved with
asphalt from the northern property line to Magnolia Street.
II. DRAINAGE BASINS AND SUB-BASINS
A. Major Basin Description
The proposed site is located within the Old Town Basin. The Old Town Drainage Basin is
located in north-central Fort Collins. The basin has a drainage area of approximately 2,120
acres, including approximately 400 acres of the Colorado State University campus. The
entire basin is urbanized, with some development dating back to the late 1800s. Generally,
the basin drains from west to east. The Old Town Basin receives some runoff water from
the Canal Importation Basin directly west of Old Town. Most of the water from Old Town
drains to the Poudre River, just to the east.
B. Sub-Basin Description
Historically, most of the site drains east to Sherwood Street.
The developed site is delineated into two sub-basins, with underground detention designed
to provide the required water quality capture volume.
Sub-basin B1, (0.074 acres), consists of an existing shed and gravel parking lots. Rainfall
travels via overland flow from east to west, into a permeable paver system. Once the flow
enters the paver system, it is conveyed to an 8’ deep dry well. The flow from the site
eventually infiltrates into the ground surface.
Sub-basin B2, (0.362 acres), consists of an existing building, landscaped area, and concrete
walkways. The addition of the dry well and replacing the sidewalk chase are the only
proposed changes to sub-basin B2. Rainfall travels via overland flow to a grass swale, where
it will be conveyed to a concrete drainage channel. Once the flow is concentrated into the
channel, it is conveyed to the flowline Sherwood Street. The flow from the site eventually
drains into the Poudre River.
Currently, offsite flows do not enter the site property. This will not change after the site has
been developed.
III. DRAINAGE CRITERIA
A. Regulations
Drainage design criteria specified in the City of Fort Collins Storm Drainage Design Criteria
and Construction Standards manual (FCSDCM) and the Urban Storm Drainage Criteria
Manual, Volume 3 by the Urban Drainage and Flood Control District (UDFCD) have been
referenced in the preparation of this study.
B. Implementation of the “Four Step Process”
The overall stormwater management strategy employed with this parking lot and alley
improvements utilizes the “Four Step Process” to minimize adverse impacts of urbanization
on receiving waters. The following is a description of how the proposed development has
incorporated each step.
Step 1 – Employ Runoff Reduction Practices. The first consideration taken in trying to
reduce the stormwater impacts of this development is the site selection itself. By selecting a
site with historically undetained runoff, the burden of development will be significantly less
with underground detention. Also, permeable pavers are used to reduce the area of
impervious surfaces, reducing the effects of imperviousness.
Step 2 – Implement BMPs That Provide a Water Quality Capture Volume (WQCV)
with Slow Release. Demolishing the existing shed, adding landscaped areas, and
constructing permeable pavers will cause stormwater runoff to increase from the site. The
runoff will be released through the bottom of a dry well. The primary water quality will
occur in the permeable pavers and dry well. Refer to the map pocket for permeable paver
details and cross-sections. The permeable pavers will increase water quality and promote
infiltration. Water quality treatment for 50% of the site is provided for in the Udall Natural
Area water treatment facility.
Step 3 – Stabilize Drainageways. The Poudre River is the governing drainageway for the
proposed site. The proposed project indirectly helps achieve a better stabilized drainageway
nonetheless. By improving the water quality and increasing infiltration, the likelihood of
bed and bank erosion from this site is greatly reduced.
Step 4 – Implement Site Specific and Other Source Control BMPs.
The Family Faith site contains a plethora of source control BMPs.
Permeable Pavement Systems: Flow from the parking lot will directly flow into the void
area of the pavers avoiding any extra pollutant-flow contact time. The sub-base of the pavers
will work to filter out any pollutants.
Dry Well: Flow entering the dry well will slowly infiltrate into the soil, after filtering out
any pollutants.
C. Development Criteria Reference and Constraints
The criteria used as the basis for analysis and design of stormwater management
improvements for this site are those found in the references cited.
To the knowledge of the author, there are no other capital drainage improvements planned
for this portion of the site; aside from those referred to above, that would constrain or
otherwise influence the design of the stormwater improvements for this site.
D. Hydrological Criteria
Stormwater runoff from the respective sub-basins of the site is analyzed for storms with 2-
year and 100-year return frequencies.
Due to the relatively small aggregate area of the tributary drainage sub-basins, the Rational
Method was chosen for use in the design of the stormwater management improvements.
The Rational Method provides that:
Q = CIA, where:
Q = Design flow in cubic feet per second (cfs)
C = Coefficient of runoff for the area under consideration
I = Rainfall intensity for the design storm duration (in/hr)
A = Area of the drainage sub-basin under consideration (ac)
Peak flows were calculated using the Rational Method for the 2-year and 100-year storm
events. This software uses the local 1-hour rainfall depth and Fort Collins rainfall
intensities developed calculate rainfall intensities as a function of the time of concentration.
These values were obtained by the City of Fort Collins Rainfall Intensity-Duration-
Frequency (IDF) curve/table; Figure 3-1 and Table 3-1a, and can be found in the Appendix.
Additionally, per City of Fort Collins, the coefficients have been multiplied by the
appropriate storm factors.
Percent imperviousness values were taken from Table RO-3, Recommended Percentage
Imperviousness Values, UDCM (See Appendix). Soils of hydrologic soil type “C”
dominate the site. Onsite runoff was calculated to determine the runoff differential between
existing and developed conditions for use in sizing the WQCV as required by the FCSDM.
The hydrologic basin parameters and runoff rates are included in the Appendices and
include quantification of the allowable volume reduction.
The standards from UDFCD Volume 2, Chapter 10, Section 3.2.3 were used to calculate the
required detention. The void space in the sub-base of the permeable pavers can contain the
entire volume of required detention, 300 cubic feet. Detention is being utilized in the sub-
base of the pavers to prevent surface ponding. The sub-base of the permeable pavers is
assumed to have a void space of 40%.
The design worksheets included in the Appendices to this Final Drainage Report present
documentation of the hydrologic calculations for the on-site storm drainage systems.
E. Hydraulic Criteria
Within this development, all runoff will be conveyed on the surface, initially as sheet flow
and subsequently as concentrated flow in shallow pans and gutters. The assessment of
required capacity and the sizing of the respective components of the drainage system are
based on the anticipated runoff from the 100-year storm event.
F. Modifications of Criteria
There are no modifications or variances requested in connection with the design of the
stormwater management for the Faith Family site development.
IV. DRAINAGE FACILITY DESIGN
A. General Concept
The storm drainage system is designed to safely convey developed storm flows by sheet
flow, concentrated pan, and gutter flow to the street flowlines.
The design worksheets included in the Appendices to this Final Drainage Report present
details of the hydrologic and hydraulic calculations pertinent to the design of the on-site
storm drainage system. A drainage plan, showing the proposed development of the site and
developed drainage patterns is included in the map pocket following the Appendices.
B. Specific Details
There are a number of collection and conveyance scenarios within the drainage regime
associated with this development. The respective scenarios are described below.
Sub-basin B1, (0.074 acres), consists of a permeable parking lot and landscaped areas. The
runoff created by a 100-Year event is increased from 0.45 cfs to 0.50 cfs with the proposed
improvements to the parking lot. Runoff will infiltrate through the permeable pavers to a
network of 4” perforated PVC pipes and drains into a proposed 8’ dry well. The well-
draining soils were encountered below the water table, but the 8’ of depth provides adequate
infiltration rates for the small basin area. (See Appendix B for calculations.)
Sub-basin B2, (0.362 acres), consists of an existing building, landscaped area, and concrete
walkways. Rainfall travels via overland flow to a grass swale, where it will be conveyed to
a concrete drainage channel. Once the flow is concentrated into the channel, it is conveyed
to the flowline Sherwood Street. The flow from the site eventually drains into the Poudre
River. There is no change in sub-basin B2 from the existing condition.
Alley, (0.094 acres), consists of an existing gravel alley that is to be paved with asphalt. The
alley design follows Fort Collins Alley Option B (drainage to one side), with a roll-over
curb. The alley flows north to south, and has a slope of 0.5%. The high point is located at
the northern property line of the site to prevent developed flows entering the neighbor’s
property to the north. The access to the alley will be reconstructed to match the proposed
flowline of the alley. The undeveloped portion of the alley follows existing drainage
patterns, flowing north to the flowline of Olive Street.
V. CONCLUSIONS
A. Compliance with Standards
The drainage design for the Faith Family site is in compliance with the requirements of the
City of Fort Collins Storm Drainage Design Criteria and Construction Standards Manual as
well as the City’s floodplain regulations. The criteria and recommendations of the Urban
Storm Drainage Criteria Manual are also reflected in the design of the drainage systems.
B. Drainage Concept
The drainage design for the Faith Family will be adequate to safely convey onsite flows
through the development. Development of the site, as proposed, should have a beneficial
impact on water quality in downstream drainage facilities and drainage ways by reducing
and delaying the initial discharge of runoff from the site such that sediments and other
potential pollutants typically carried by this first flush are removed from the flow. The
proposed drainage improvements cause no adverse impact to the adjacent properties.
VI. REFERENCES
“City of Fort Collins Stormwater Criteria Manual”, City of Fort Collins, Adopted December
2011
“City of Fort Collins Municipal Code”, Chapter 10 – Flood Protection and Prevention City of
Fort Collins, 1987
Urban Storm Drainage Criteria Manual, Volumes 1, 2, and 3, Urban Drainage and Flood Control
District, April 2008
APPENDIX A: Hydrologic Computations
Vicinity Map
Fort Collins Flood Map
FEMA Firm Panel 08069C0979H
USGS Soil Map
Fort Collins Rainfall Intensity Curve
Fort Collins Rainfall Intensity Table
Table RO-3 Recommended Percentage Imperviousness Values
Rational Method Calculated Runoff Coefficients
Rational Method Calculated Imperviousness
Rational Method Calculated Flows
Rational Method Calculated Composite C Tables
Rational Method Calculated Imperviousness
Rational Method Calculated Flows
Soil Map—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
10/13/2016
Page 1 of 3
4492470 4492480 4492490 4492500 4492510 4492520 4492530 4492540 4492550 4492560 4492570
4492470 4492480 4492490 4492500 4492510 4492520 4492530 4492540 4492550 4492560 4492570
492750 492760 492770 492780 492790 492800 492810 492820 492830 492840 492850 492860 492870 492880 492890 492900
492750 492760 492770 492780 492790 492800 492810 492820 492830 492840 492850 492860 492870 492880 492890 492900
40° 35' 2'' N
105° 5' 8'' W
40° 35' 2'' N
105° 5' 1'' W
40° 34' 58'' N
105° 5' 8'' W
40° 34' 58'' N
105° 5' 1'' W
N
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84
0 35 70 140 210
Feet
0 10 20 40 60
Meters
Map Scale: 1:720 if printed on A landscape (11" x 8.5") sheet.
Warning: Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Map Unit Polygons
Soil Map Unit Lines
Soil Map Unit Points
Special Point Features
Blowout
Borrow Pit
Clay Spot
Closed Depression
Gravel Pit
Gravelly Spot
Landfill
Lava Flow
Marsh or swamp
Mine or Quarry
Miscellaneous Water
Perennial Water
Rock Outcrop
Saline Spot
Sandy Spot
Severely Eroded Spot
Sinkhole
Slide or Slip
Sodic Spot
Spoil Area
Stony Spot
Very Stony Spot
Wet Spot
Other
Special Line Features
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at 1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil line
placement. The maps do not show the small areas of contrasting
soils that could have been shown at a more detailed scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL: http://websoilsurvey.nrcs.usda.gov
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more accurate
calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as of
Map Unit Legend
Larimer County Area, Colorado (CO644)
Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI
35 Fort Collins loam, 0 to 3 percent
slopes
0.5 100.0%
Totals for Area of Interest 0.5 100.0%
Soil Map—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
10/13/2016
Page 3 of 3
DRAINAGE CRITERIA MANUAL (V. 1) RUNOFF
Table RO-3—Recommended Percentage Imperviousness Values
Land Use or
Surface Characteristics
Percentage
Imperviousness
Business:
Commercial areas 95
Neighborhood areas 85
Residential:
Single-family *
Multi-unit (detached) 60
Multi-unit (attached) 75
Half-acre lot or larger *
Apartments 80
Industrial:
Light areas 80
Heavy areas 90
Parks, cemeteries 5
Playgrounds 10
Schools 50
Railroad yard areas 15
Undeveloped Areas:
Historic flow analysis 2
Greenbelts, agricultural 2
Off-site flow analysis
(when land use not defined)
45
Streets:
Paved 100
Gravel (packed) 40
Drive and walks 90
Roofs 90
Lawns, sandy soil 0
Lawns, clayey soil 0
* See Figures RO-3 through RO-5 for percentage imperviousness.
C K 1 . 31 i 3 1 . 44 i 2 1 . 135 i 0 . 12
A A for CA 0, otherwise CA = 0 (RO-6)
C K 0 . 858 i 3 0 . 786 i 2 0 . 774 i 0 . 04
CD CD (RO-7)
C 2
B A CD
C C
2007-01 RO-9
Urban Drainage and Flood Control District
Composite C Values
FAITH FAMILY
Asphalt Area (acres) Concrete Area (acres) Gravel (acres) Roofs (acres) Lawns (acres) Total Area Minor (2-YR) Major (100-YR)
(C = 0.95) (C = 0.95) (C = 0.50) (C = 0.95) (C = 0.15) (acres) Composite "C" Composite "C" (Cf x C)
E1 E1 0.000 0.000 0.055 0.009 0.010 0.074 0.51 0.63
E2 E2 0.000 0.051 0.000 0.143 0.168 0.362 0.58 0.72
ALLEY ALLEY 0.000 0.000 0.058 0.000 0.036 0.094 0.37 0.46
D1 B1 0.016 0.012 0.019 0.000 0.027 0.074 0.54 0.68
D2 B2 0.000 0.051 0.000 0.143 0.168 0.362 0.58 0.72
ALLEY ALLEY 0.072 0.017 0.000 0.000 0.005 0.094 0.91 1.00
Notes:
Composite C values obtained from Table R0-11
Major Storm Runoff factored per Table R0-12
Developed
Design Point Basin(s)
Existing
MAP Faith Family Rational Method.xlsx 2/27/2017
Imperviousness
FAITH FAMILY
Asphalt Area (acres) Concrete Area (acres) Gravel (acres) Roofs (acres) Lawns (acres) Total Area Percent
(I = 100) (I = 100) (I = 40) (I = 90) (I = 0) (acres) Imperviousness
E1 E1 0.000 0.000 0.055 0.009 0.010 0.0740 41%
E2 E2 0.000 0.051 0.000 0.143 0.168 0.3620 50%
ALLEY ALLEY 0.000 0.000 0.058 0.000 0.036 0.0940 25%
D1 B1 0.016 0.012 0.019 0.000 0.027 0.074 48%
D2 B2 0.000 0.051 0.000 0.143 0.168 0.362 50%
ALLEY ALLEY 0.072 0.017 0.000 0.000 0.005 0.094 95%
Notes:
Percent Impervious Values per Table R0-3, Urban Drainage Manual
Developed
Design Point Basin (s)
Existing
CAG Faith Family Rational Method.xlsx 2/27/2017
Basin Flow Calculations
FAITH FAMILY
Area Minor Major
(acres) Composite "C" Composite "C" Length (ft) Slope (%)
Minor tov
(min)
a
Major tov
(min)
a Length (ft)
Slope
(%)
Channel
Type
Velocity
(fps)
c t
t (min)
Minor TC
(min)
Major TC
(min) 2-yr 10-yr 100-yr 2-yr 10-yr 100-yr
E1 E1 0.0740 0.51 0.63 17 0.84 4.84 3.81 0 0.40 PA 1.26 0.00 5.00 5.00 2.85 4.87 9.95 0.11 0.18 0.47
E2 E2 0.3620 0.58 0.72 110 1.20 9.62 6.95 86 0.75 PA 1.73 0.83 10.45 7.78 2.17 3.71 8.38 0.45 0.78 2.19
ALLEY ALLEY 0.0940 0.37 0.46 15 1.20 5.00 4.38 200 0.40 PA 1.26 2.64 7.64 7.01 2.46 4.21 8.80 0.08 0.14 0.38
D1 B1 0.0740 0.54 0.68 40 2.00 5.23 3.96 0 0.50 PA 1.41 0.0000 5.23 5.00 2.85 4.87 9.95 0.11 0.20 0.50
D2 B2 0.3620 0.58 0.72 110 1.20 9.62 6.95 86 0.75 PA 1.73 0.8275 10.45 7.78 2.17 3.71 8.38 0.45 0.78 2.19
ALLEY ALLEY 0.0940 0.91 1.00 15 1.50 1.22 0.63 200 0.50 PA 1.41 2.3570 5.00 5.00 2.85 4.87 9.95 0.24 0.42 0.94
Notes:
a
b
HM = Heavy Meadow, TF = Tillage/field, PL = Short pasture and lawns, BG = Nearly bare ground, GW = Grassed Waterway, PA = Paved Areas
c
Velocity alues from Figure 3-3/Table RO-2 Estimate of Average Flow Velocity for use with the Rational Method
Design
Point
Developed
Existing
Initial/Overland Time Final TC Intensity (in/hr) Basin Flows (cfs)
Basin (s)
Travel Time
1 / 3
1 . 87 ( 1 . 1 ) 1 / 2
S
CC D
t f
ov
CAG Faith Family Rational Method.xlsx 2/27/2017
APPENDIX B: Hydraulic Computations
Fort Collins Modified FFA Method
Underground Detention Calculation
Infiltration Calculation
Project:
Basin ID:
Design Information (Input): Design Information (Input):
Catchment Drainage Imperviousness Ia
= 48.00 percent Catchment Drainage Imperviousness I
a = 48.00 percent
Catchment Drainage Area A = 0.074 acres Catchment Drainage Area A = 0.074 acres
Predevelopment NRCS Soil Group Type = C A, B, C, or D Predevelopment NRCS Soil Group Type = C A, B, C, or D
Return Period for Detention Control T = 2 years (2, 5, 10, 25, 50, or 100) Return Period for Detention Control T = 100 years (2, 5, 10, 25, 50, or 100)
Time of Concentration of Watershed Tc = 5 minutes Time of Concentration of Watershed Tc = 5 minutes
Allowable Unit Release Rate q = 1.48 cfs/acre Allowable Unit Release Rate q = 1.48 cfs/acre
Determination of Average Outflow from the Basin (Calculated): Determination of Average Outflow from the Basin (Calculated):
Runoff Coefficient C = 0.53 Runoff Coefficient C = 0.67
Inflow Peak Runoff Qp-in = 0.59 cfs Inflow Peak Runoff Qp-in = 2.19 cfs
Allowable Peak Outflow Rate Qp-out = 0.11 cfs Allowable Peak Outflow Rate Qp-out = 0.01 cfs
Mod. FAA Minor Storage Volume = 2.722 cubic ft Mod. FAA Major Storage Volume = 485 cubic ft
5 <- Enter Rainfall Duration Incremental Increase Value Here (e.g. 5 for 5-Minutes)
Rainfall Rainfall Inflow Adjustment Average Outflow Storage Rainfall Rainfall Inflow Adjustment Average Outflow Storage
Duration Intensity Volume Factor Outflow Volume Volume Duration Intensity Volume Factor Outflow Volume Volume
minutes inches / hr cubic feet "m" cfs cubic feet cubic feet minutes inches / hr cubic feet "m" cfs cubic feet cubic feet
(input) (output) (output) (output) (output) (output) (output) (input) (output) (output) (output) (output) (output) (output)
0 0.00 0.000 0.00 0.00 0.000 0.000 0 0.00 0.000 0.00 0.00 0.000 0.000
5 2.85 33.533 1.00 0.11 32.856 0.677 5 9.95 147.996 1.00 0.01 3.900 144.096
10 2.21 52.006 0.75 0.08 49.284 2.722 10 7.72 229.655 0.75 0.01 5.850 223.805
15 1.87 66.007 0.67 0.07 65.712 0.295 15 6.52 290.935 0.67 0.01 7.800 283.135
20 1.61 75.773 0.63 0.07 82.140 -6.367 20 5.60 333.178 0.63 0.01 9.750 323.428
25 1.43 84.127 0.60 0.07 98.568 -14.441 25 4.98 370.363 0.60 0.01 11.700 358.663
30 1.30 91.775 0.58 0.06 114.996 -23.221 30 4.52 403.383 0.58 0.01 13.650 389.733
35 1.17 96.364 0.57 0.06 131.424 -35.060 35 4.08 424.801 0.57 0.01 15.600 409.201
40 1.07 100.717 0.56 0.06 147.852 -47.135 40 3.74 445.030 0.56 0.01 17.550 427.480
45 0.99 104.835 0.56 0.06 164.280 -59.445 45 3.46 463.176 0.56 0.01 19.500 443.676
50 0.92 108.247 0.55 0.06 180.708 -72.461 50 3.23 480.430 0.55 0.01 21.450 458.980
55 0.87 112.601 0.55 0.06 197.136 -84.535 55 3.03 495.750 0.55 0.01 23.400 472.350
60 0.82 115.777 0.54 0.06 213.564 -97.787 60 2.86 510.476 0.54 0.01 25.350 485.126
Determination of MINOR Detention Volume Using Modified FAA Method Determination of MAJOR Detention Volume Using Modified FAA Method
DETENTION VOLUME BY THE MODIFIED FAA METHOD
Faith Family
(For catchments less than 160 acres only. For larger catchments, use hydrograph routing method)
(NOTE: for catchments larger than 90 acres, CUHP hydrograph and routing are recommended)
Project:
Basin ID:
Design Information (Input):
Width of Basin Bottom, W = ft Right Triangle OR…
Length of Basin Bottom, L = ft Isosceles Triangle OR…
Dam Side-slope (H:V), Zd
= ft/ft Rectangle OR…
Circle / Ellipse OR…
Irregular (Use Overide values in cells G32:G52)
MINOR MAJOR
Storage Requirement from Sheet 'Modified FAA': 0.00 0.01 acre-ft.
Stage-Storage Relationship: Storage Requirement from Sheet 'Hydrograph': acre-ft.
Storage Requirement from Sheet 'Full-Spectrum': acre-ft.
Labels Water Side Basin Basin Surface Surface Volume Surface Volume Target Volumes
for WQCV, Minor, Surface Slope Width at Length at Area at Area at Below Area at Below for WQCV, Minor,
& Major Storage Elevation (H:V) Stage Stage Stage Stage Stage Stage Stage & Major Storage
Stages ft ft/ft ft ft ft
2
ft
2
User ft
3
acres acre-ft Volumes
(input) (input) Below El. (output) (output) (output) Overide (output) (output) (output) (for goal seek)
4999.85 (input) 384 0 0.009 0.000
5000.18 0.00 0.00 384 127 0.009 0.003
5000.51 0.00 0.00 384 253 0.009 0.006
5000.84 0.00 0.00 384 380 0.009 0.009
5001.17 0.00 0.00 288 491 0.007 0.011 100-YR
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
Project No: 7040-007
Project Name: Faith Family
Designer: RJP
Date: 3/10/2017
Basin: B2
0.85 in/hr or 1.96759E-05 ft/sec
* Infiltation Rate taken from soils report
961 sq. ft.
0.019 cfs Safty Factor 1.5
0.013 cfs
485 cubic ft
38475 seconds or 10.7 hrs
Infiltration Calculator
Infiltration Rate f=
Surface Area
Allowable Infiltrating Flow
Required100-YR Event Volume
Time to Drain
(100-YR Event Volume/ Final Infiltrating Flow)
Final Allowable Infiltrating Flow
Quality Engineering
2637 Midpoint Drive, Suite E
Fort Collins, CO 80525 (970) 416-7891
APPENDIX C: Map Pocket
Drainage Plan
WS
WS WS
WS
WS
WS
WS
EXISTING WOOD DECK
EXISTING WOOD PORCH
EXISTING 0.5' WIDE
BRICK WALL
EXISTING 10" DIAMETER COLUMN (TYP)
EXISTING 0.5' WIDE
CONCRETE WALL
EXISTING DRAIN CHASE
DRAIN CHASE
EXISTING CONCRETE RAMP
-EXISTING SIDEWALK-
-EXISTING SIDEWALK-
-EXISTING SIDEWALK-
-EXISTING SIDEWALK-
-EXISTING 5' SW-
EXISTING CONCRETE PAN
-GRASS-
-GRASS-
-GRASS-
-GRASS-
-GRASS-
SS SS SS SS SS SS SS SS SS SS SS SS
EXISTING SANITARY CLEANOUT
CONCRETE
COURTYARD
EXISTING CONCRETE STAIRS
2 STORY
RESIDENTIAL
FRAME
NO BASEMENT
2 STORY
RESIDENTIAL
FRAME & BRICK
WITH BASEMENT
SOUTH SHERWOOD STREET
321 SOUTH SHERWOOD STREET
PARCEL 1
9,500 SQ.FT.
0.218 ACRES
317 SOUTH SHERWOOD STREET
PARCEL 2
9,500 SQ.FT.
0.218 ACRES
EXISTING WOOD SHED
EXISTING WATER VALVE
BLOCK 73
ALLEY
EXISTING GATE
(UP)
(UP)
(UP)
(UP)
W W W W W W W W W W W W W
WS WS WS WS WS WS WS
EXISTING 2" COPPER FIRE SERVICE
EXISTING 3/4" COPPER SERVICE
6" SANITARY SEWER 8" SANITARY SEWER
SIGN "2 HOUR PARKING"
4" CAST IRON WATER LINE
325 SHERWOOD STREET
512 WEST MAGNOLIA STREET
EXISTING 5' SW
EXISTING DRAIN CHASE
EXISTING VERTICAL CURB
& GUTTER (TYP)
-EXISTING ACCESS-
FS
FS
FS FS FS
WS
WS
WS
WS
WS
WS
SMH #1
RIM=5002.2
8" RCP (S) INV=4996.6
8" RCP (N) INV=4996.5
-EXISTING ACCESS-
BLOCK 73
ALLEY
8" SANITARY SEWER 6" SANITARY SEWER
DRAIN CHASE
EXISTING WATER VALVE
EXISTING VERTICAL CURB
& GUTTER (TYP)
EXISTING 5' SW
-EXISTING SIDEWALK-
-EXISTING ACCESS-
SMH #1
RIM=5002.2
8" RCP (S) INV=4996.6
8" RCP (N) INV=4996.5
-EXISTING ACCESS-
325 SHERWOOD STREET
EXISTING 0.5' WIDE
CONCRETE WALL
EXISTING CONCRETE RAMP
PROPOSED
ROLL-OVER CURB
10' C4.0
SCALE: 1" = 10'
0 20'
FAITH FAMILY HOSPITALITY
317-321 SHERWOOD STREET
FORT COLLINS, CO 80521
FOR BURIED UTILITY INFORMATION
THREE (3) BUSINESS DAYS
BEFORE YOU DIG
CALL 811
(OR 1-800-922-1987)
UTILITY NOTIFICATION
CENTER OF COLORADO (UNCC)
WWW.UNCC.ORG
R
D2
SYMBOL LEGEND
G G
(UP)
(UT)
SS
X
WS WS WS WS
SS
R/W
WS WS
W
R/W
(OHP)
EP
W
FS
E
NOTE: ALL EXISTING TREES TO BE PROTECTED IN PLACE
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
#N/A #N/A
STAGE-STORAGE SIZING FOR DETENTION BASINS
Faith Family
Check Basin Shape
Underground Storage
UD-Detention_v2.34 underground.xls, Basin 3/27/2017, 2:03 PM
the version date(s) listed below.
Soil Survey Area: Larimer County Area, Colorado
Survey Area Data: Version 10, Sep 22, 2015
Soil map units are labeled (as space allows) for map scales 1:50,000
or larger.
Date(s) aerial images were photographed: Apr 22, 2011—Apr 28,
2011
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor shifting
of map unit boundaries may be evident.
Soil Map—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
10/13/2016
Page 2 of 3