HomeMy WebLinkAbout625 S. PETERSON MULTI-FAMILY - PDP - PDP160005 - PLANS - ELEVATIONSEXISTING ROOF LEVEL
116' - 11 3/4"
GROUND LEVEL
96' - 3"
EXISTING LEVEL 2
106' - 9 5/8"
EXISTING LEVEL 1
97' - 3"
NEW LEVEL 2
110' - 0 1/8"
NEW LEVEL 1
100' - 0"
5 4 3 2 1
30'-0" ABOVE ADJACENT FINISHED GRADE
PEAK OF ADDITION IN REAR APPROX.
25'-0" ABOVE ADJACENT FINISHED GRADE
PEAK OF ORIGINAL HOUSE APPROX.
ADDITION ROOF LEVEL
118' - 1 1/4"
REMOVE EXISTING NON-ORIGINAL PORCH AND
RECONSTRUCT IN SIMILAR SIZE AND CONFIGURATION
REMOVE EXISTING NON-ORIGINAL DOOR AND REPLACE
WITH NEW DECORATIVE WOOD DOOR WITH UPPER VISION
LITES
EXISTING ROOF LEVEL
116' - 11 3/4"
GROUND LEVEL
96' - 3"
EXISTING LEVEL 2
106' - 9 5/8"
EXISTING LEVEL 1
97' - 3"
26'-9"ABOVE ADJACENT FINISHED GRADE
PEAK OF PRIMARY ROOF (6:12 PITCH) AT APPROX.
NEW LEVEL 2
110' - 0 1/8"
NEW LEVEL 1
100' - 0"
30'-0" ABOVE ADJACENT FINISHED GRADE
PEAK OF CROSS GABLE ADDITION IN REAR APPROX.
F E D C B A
ADDITION ROOF LEVEL
118' - 1 1/4"
FRAME/INFILL EXISTING
WINDOW OPENING
CUT AND FRAME NEW PAIRED WINDOW
OPENING TO MATCH ADJACENT
SYNTHETIC STUCCO FINISH OVER CONCRETE
FOUNDATION WALL WITH VERTICAL SCORE
JOINTS EVENLY SPACED AT 4'-0" O.C.
(4991.0 ACTUAL)
0 1/2" 1" 2"
5 4 3 2 1
A
B
C
D
PROJECT
DATE
DRAWN
EXISTING ROOF LEVEL
116' - 11 3/4"
GROUND LEVEL
96' - 3"
EXISTING LEVEL 2
106' - 9 5/8"
EXISTING LEVEL 1
97' - 3"
NEW LEVEL 2
110' - 0 1/8"
NEW LEVEL 1
100' - 0"
30'-0" ABOVE ADJACENT FINISHED GRADE
PEAK OF CROSS GABLE ADDITION IN REAR APPROX.
A B C D E F
ADDITION ROOF LEVEL
118' - 1 1/4"
AT APPROX. 26'9" ABOVE ADJACENT FINISHED GRADE
PEAK OF PRIMARY ROOF (6:12 PITCH)
25'-0" ABOVE ADJACENT FINISHED GRADE
PEAK OF ORIGINAL HOUSE APPROX.
DASHED LINE INDICATE APPROXIMATE
CONFIGURATION OF EXISTING ROOFLINE
NEW EAST/WEST GABLE END
ADDITION AND HIPPED DORMER
ON WEST END OF EXISTING HOUSE
FRAME/INFILL EXISTING NON-
ORIGINAL WINDOW
EXISTING ROOF LEVEL
116' - 11 3/4"
GROUND LEVEL
96' - 3"
EXISTING LEVEL 2
106' - 9 5/8"
EXISTING LEVEL 1
97' - 3"
NEW LEVEL 2
110' - 0 1/8"
NEW LEVEL 1
100' - 0"
1 2 3 4 5
30'-0" ABOVE ADJACENT FINISHED GRADE
PEAK OF CROSS GABLEADDITION IN REAR APPROX.
ADDITION ROOF LEVEL
118' - 1 1/4"
0 1/2" 1" 2"
5 4 3 2 1
A
B
C
D
PROJECT
DATE
DRAWN
712 WHALERS WAY SUITE, B-100
FORT COLLINS, CO 80525
(970) 223-1820
www.alm2s.com
PRINTED 1/29/2016 5:03:35 PM FILE NAME:
Schematic Design
0000-Project-SD.rvt
BUILDING ELEVATIONS
1537
Author
11/30/2015
A4.2
Heitmann Properties, LLC
Fort Collins, Colorado
625 S. Peterson St. Multi-Family Housing
A4.2 SCALE: 3/16" = 1'-0"
1 SOUTH ELEVATION
A4.2 SCALE: 3/16" = 1'-0"
2 WEST ELEVATION
SYSTEM NOTES
NO ISSUE DATE
712 WHALERS WAY SUITE, B-100
FORT COLLINS, CO 80525
(970) 223-1820
www.alm2s.com
PRINTED 1/29/2016 5:03:28 PM FILE NAME:
Schematic Design
0000-Project-SD.rvt
BUILDING ELEVATIONS
1537
Author
11/30/2015
A4.1
Heitmann Properties, LLC
Fort Collins, Colorado
625 S. Peterson St. Multi-Family Housing
A4.1 SCALE: 3/16" = 1'-0"
2 EAST ELEVATION
A4.1 SCALE: 3/16" = 1'-0"
1 NORTH ELEVATION
SYSTEM NOTES
NO ISSUE DATE
GENERAL NOTES REGARDING ORIGINAL HOUSE:
ORIGINAL ROOF HAS BEEN REPLACED WITH MULTIPLE LAYERS OF
SHINGLES. REMOVE ALL LAYERS DOWN TO ORIGINAL SKIP
SHEATHING. COVER ENTIRE ROOF WITH NEW 7/16" OSB
SHEATHING, ICE/WATER SHIELD, GALV. METAL FLASHINGS & 30-
YEAR HIGH-PROFILE LAMINATED FIBERGLASS SHINGLES - COLOR
TO BE "WEATHERED WOOD".
ENTIRE HOUSE WAS COVERED WITH STEEL SIDING IN THE 1970s OR
80s. REMOVE EXISTING STEEL SIDING AND FASCIA TRIM. IF
ORIGINAL WOOD SIDING IS STILL IN PLACE, PATCH AND REPAIR AS
REQUIRED. IF ORIGINAL SIDING/TRIM IS IN POOR CONDITION
AND CANNOT BE SALVAGED, REPLACE WITH NEW EXTERIOR
SHEATHING, AIR BARRIER AND PAINTED HARDBOARD SIDING IN
SIMILAR SIZE AND PROFILE.
ALL ORIGINAL WOOD WINDOWS HAVE BEEN REPLACED OVER THE
YEARS. REMOVE ALL EXISTING, NON-ORIGINAL VINYL AND METAL
WINDOWS AND REPLACE WITH NEW PERIOD-APPROPRIATE
ALUM.-CLAD WOOD WINDOWS.
INTERIOR OF HOUSE TO BE STRIPPED DOWN TO WOOD STUD
FRAMING INCLUDING REMOVAL OF ALL LATH & PLASTER AND
DRYWALL. STUD CAVITIES TO BE FILLED W/ SPRAY-FOAM
INSULATION AFTER ROUGH-IN OF NEW ELECTRICAL, MECHANICAL
AND PLUMBING.
GENERAL NOTES REGARDING ADDITION IN REAR:
EXTERIOR WALLS TO BE 2x6 STUD FRAMING W/ R-20 HIGH-
PERFORMANCE BATT INSULATION & SHEATHED W/ OSB, AIR-
BARRIER & PAINTED HARDBOARD SIDING IN SIMILAR SIZE &
PROFILE.
NEW ALUM.-CLAD WOOD WINDOWS TO MATCH.
FINISHED FLOOR OF ADDITION IN REAR IS SET UP HIGHER THAN
FINISHED FLOOR OF ORIGINAL HOUSE BASED ON CITY OF FORT
COLLINS STORMWATER DEPARTMENT RECOMMENDATIONS TO
ELEVATE FINISHED FLOOR 24" ABOVE BASE FLOOD ELEVATION (BFE).